JENCO INSTRUMENTS, INC. JENCO ELECTRONICS, LTD ARJONS DR., SUITE C P.O. BOX LINKOU-117

Similar documents
OPERATION MANUAL. THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

JENCO ELECTRONICS, LTD.

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

Microprocessor Digital Thermometer

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

203RE ph v 1.0 Instructions

1 4 DIN Dissolved Oxygen Controller

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Digital Temperature Calibrator - Thermometer MODEL 840A, 845, 850, 855

Slope Zero MEAS CAL ALARM CONF APT2000 PH ENCLOSURE TYPE 2

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

HydroMaster USER S GUIDE HM-500

Rosemount 372. HF Resistant ph sensor. Quick Start Guide LIQ-QSG-372 Rev. C June 2017

Retractable ph/orp Sensor

ph/orp-7500 ph/orp Transmitting controller Operation manual

GMH 285 / GMH 285-BNC

4-IN-1 PIN/PAD RH MOISTURE METER

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Standard SPECIFICATIONS FEATURES APPLICATIONS

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Instruments. for hydroponics & horticulture 2016

Wireless Humidity/ Temperature Monitor Remote Wireless Sensor

Model Q45P/R. ph/orp Monitor...

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS MD5-601 AND MD5-603

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

ExStik DO600 USER GUIDE. Dissolved Oxygen Meter. 99 Washington Street Melrose, MA Phone Toll Free

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. DIGITAL CHILLING INCUBATOR MODELS MD5-600, MD5-602, AND MD5-604

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Barnant Company MODEL NO

Single Channel Heater Controller

CALIBRATABLE 7-FUNCTION THERMO- HYGROMETER USER S MANUAL

hhtp:// CL23A, 24, 25, 26, 27 Digital Calibrator/Thermometer

MEAS CAL ALARM WASH CONF APT4000 TC

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

Model Q45P/R. ph/orp Monitor...

POWER METER INSTRUCTION MANUAL

Use this Specification Template to develop a specification to be used for requesting a quote or defining a job work description.

INSTRUCTION MANUAL ROTARY LASER LEVEL GPR-R40H / G40

ORP (mv) Controller Model: ORP-XP2. UP DOWN ENTER Time & Date Main Menu Alarm Reset

MODEL OX-07 Type A INSTRUCTION MANUAL FOR RIKEN PORTABLE OXYGEN MONITOR PT0E-0860

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

Model: LD5 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

Automatic Humidity Controller. Model 512 (Revision C) Operating Manual

DICKSON KT6 DICKSON. Temperature Chart Recorder. Specifications. Product. Display Symbols. Information & Operating. Contents:

OPERATING MANUAL BFS-MP SERIES FREEZING STAGES

Model 1916-C/-R Hand-held Optical Power Meter

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

MS200/300/400 Hotplate Magnetic Stirrer Instruction Manual

OPERATING MANUAL. EchoThermJ DIGITAL HOT PLATE MODEL HP30 AND HP30A. DOCUMENT NUMBER HP30-03 Revised 10 December 2011

CG Series Digital Temperature Controller OPERATIONS MANUAL

Sirius Technologies, Inc.

Hydrazine Analyzer Series 2171 Specifications

MODEL ORP/pH Digital Controller

Manual Vane Anemometer PCE-VA 20

Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

Black Body Calibration Source User Manual

Customers must fill in and mail the warranty card in order to activate the warranty.

PH/ORP Online Analyzer

KANE-ALERT-CO 2 Monitor with Temperature

Quick Start Guide LIQ-QSG-Hx338, Rev M July Rosemount Hx338. Steam Sterilizable and Autoclavable ph Sensor

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

Dual-Diode Dosimeter Patient Dose Monitor

Sub psi SPECIFICATIONS

IMR Environmental Equipment, Inc Central Ave. St. Petersburg, FL Phone:

Excellence through Versatility

CALIBRATABLE 3-FUNCTION THERMO- HYGROMETER USER S MANUAL

Toroidal Conductivity Transmitters Series APT4000 Specifications

Digital Salt / TDS Meter. 390a. The Value Leader TM

Concise catalogue Water-Industry

Operating Instructions

MICROCAPSTAR End-Tidal CO 2 Analyzer Instruction Manual

Ambient Weather WS-2063 Indoor Temperature and Humidity Monitor with Backlight User Manual

JDDT1 - Single Stage Digital Thermostat

Advance Optima Module Magnos 17

CMT MANUAL 6. NMC SENSORS

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

CO2 Monitor Operating Instructions

HTO-45 HUMIDITY TEMPERATURE PROBE INSTRUCTION MANUAL

Mark 25 Ultrapure Water Conductivity Analyzer

NTC THERMISTOR SENSOR PERFORMANCE

CDL 210. Operating manual. CO2 Logger. Best.-Nr

INSTRUCTION MANUAL 4-WAY BALL VALVE Digital Manifold

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

Operating Instructions

SGA71. Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG

The data logger is supplied with a lithium metal battery which typically gives two years logging life.

Humidity Meters. hygrometers & therma-hygrometers. what is a hygrometer? applications. monitor humidity levels for better health. Humidity.

Infrared Moisture Balance (FD-660)

Dual Laser InfraRed (IR) Thermometer

ABSOLUTE Temperature Control System

i-cube Microplate Incubator E10030

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

108A OTP1800. Grid Support. General Description

Transcription:

OPERATION MANUAL JENCO MODEL 6173 MICROCOMPUTER BASED ph/mv/temperature BENCH METER JENCO INSTRUMENTS, INC. JENCO ELECTRONICS, LTD. 7968 ARJONS DR., SUITE C P.O. BOX LINKOU-117 SAN DIEGO, CA 92126 TAIPEI HSIEN, TAIWAN,R.O.C. TEL: (858) 578-2828 TEL: (886-2)2601-6191 FAX: (858) 578-2886 FAX: (886-2)2601-7206 E-Mail:jencoi@ix.netcom.com E-Mail:jencoe@ms2.hinet.net SHANGHAI JENCO ELECTRONICS, LTD. 18 WANGDONG ZHONG ROAD,SIJING, SONGJING,SHANGHAI,CHINA,20160 TEL: 86-215-761-9599 FAX: 86-215-761-9598 E-Mail:jenco@public.sta.net.cn WEBSITE : http://www.jenco.com.cn

INITIAL INSPECTION Carefully unpack the instrument and accessories. Inspect for damages made in shipment. If any damage is found, notify your Jenco representative immediately. All packing materials should be saved until satisfactory operation is confirmed. GENERAL INTRODUCTION The model 6173 is a precise instrument for the measurement of ph, mv and temperature. A built-in microcomputer is used to store, calculate and compensate for all the relevant parameters relating to ph determinations. These include temperature characteristics of the ph electrode, buffer solutions and electrode slope deviations. The mechanical touch keys are highly reliable with tactile and audio feedback. This meter can operated with six 1.5V batteries. Re-calibration is not required when power is turned on again. The meter has a large LCD that displays the ph (mv) and temperature simultaneously along with the user-prompting mode indication annunciators. The instrument prompts the user through the calibration and measurement procedures. An AUTOLOCK feature is provided for both ph and mv measurements. This enables the instrument to automatically sense the end point and "lock" the reading to indicate the end point value of a measurement. The 6173 can also be used in the non-autolock mode. The AUTOLOCK and the user prompting features help eliminate most of the errors in the determination of ph and mv values. 2

The model 6173 uses ph and ORP electrodes with BNC connectors and interchangeable ATC ( Automatic Temperature Compensation ) / Temperature probes. Other features include electrode offset recognition, electrode slope recognition, electrode efficiency display, built in buffer coefficients, automatic or manual temperature compensation. BATTERIES REPLACEMENT Follow the procedures to replace the internal batteries. 1. Replace batteries when the BAT indicator appears on the LCD. The instrument can operate within specifications for approximately one hour after BAT starts to appear. 2. The battery compartment is located at the bottom side of the meter (Refer to Figure 1). Flip the meter over so that the bottom side is facing up. Lift the battery cover to expose the battery compartment. 3. Replace all six type AA batteries. 4. Replace battery cover.. Figure 1 3

TURNING ON/OFF THE INSTRUMENT When the instrument is not in use, press the ON/OFF key to turn off the instrument. Unplugging the AC adaptor from the instrument or from the AC line does not turn off the instrument. It would automatically switch to the internal batteries. The instrument will continue to operate on the internal batteries. ABOUT LCD DISPLAY Figure2 1.AUTOLOCK :In the autolock mode 2.BAT. :Low battery indicator 3.HOLD :Input is locked 4.WAIT :Waiting to lock 4

5.mV :mv unit 6.pH :ph unit 7.UNIT :Unit indicator 8.ATC :ATC mode indicator 9.MAN :MANUAL mode indicator 10.EFFICIENCY:Efficiency of electrode 11.SLOPE :Calibration indicator 12.STAND :Calibration indicator 13. 14.00 :Main LCD display 14.% :Efficiency unit 15.25.0 :Second LCD display 16. :Temperature unit KEY FUNCTIONS OF THE MODEL 6173 Figure3 1. [MODE] key : The [MODE] key selects the parameters to be displayed. Pressing the [MODE] key changes the display sequentially to display : ph-autolock, mv-autolock, ph and mv. The calibration values will not be affected by changing the display modes. 5

2.&3. [STAND] and [SLOPE] keys:the [STAND] and [SLOPE] keys are used for dual point ph calibration of the instrument. Pressing and holding the [STAND] key while turning on the power,will chang the buffer set to the other available buffer set. 4.[MEA./EFF.] key :a. The [MEA./EFF.] key is used to bring the instrument out of the AUTOLOCK condition when operating in the ph-autolock or mv-autolock mode. b. Press and hold this key for 5 seconds, the large LCD will display the efficiency of the electrode. 5.&6. The [ ] and [ ] keys :The [ ] and [ ] keys are used to manually enter the temperature values. They have no effect on the instrument when operating in ATC mode. 7. [CLEAR] key : The [CLEAR] key is used to clear all calibration values stored in the internal memory. Under normal use the key will not be activated unless pressed and held for 2 seconds. 8.[ON/OFF] key :The [ON/OFF] key turns the instrument on or off. The ph calibration values will not be erased when the instrument is turned off. 6

CONNECTOR Figure 4 1.RS-232 connector 3.ATC connector 5.pH/ORP connector 2. AC adaptor input connector 4. Ref. Input connector OPERATIONAL PROCEDURES BUFFER TABLE SELECT There are two sets of buffer available for this unit : 4.01,7.00, 10.01pH and 4.00,6.86, 9.18pH. You can change the buffer set by turning off the unit then press and hold the [STAND] key as you turn on the unit again. ph CALIBRATION Turn on the instrument by pressing the [ON/OFF] key. When turn on, the display maintains at the same mode before shut down. 7

1. Calibration with an ATC/Temp probe in the ph-autolock mode. 1.1 Connect the ph electrode to the BNC connector and the ATC/Temp probe to the ATC/Temp connector of the instrument. The ATC annunciator on the LCD will be on. Press the [MODE] key if necessary to go to ph-autolock mode. 1.2 Rinse the ph electrode and ATC/Temp probe in distilled water and immerse them in ph buffer 7.00(6.86). The instrument will display the buffer temperature. 1.3 Press the [STAND] key. The STAND annunciator will be on and the WAIT annunciator will flash. At this time the instrument is waiting for a stable reading. The display will be locked to the buffer value corresponding to the temperature of buffer 7.00 (6.86) as set in 1.2. When a stable reading is reached, the WAIT annunciator will stop flashing and stay off. The SLOPE annunciator will start to flash. This means that the standardization at buffer 7.00(6.86) has been completed and the instrument is now ready to be sloped at a second buffer. Allow sufficient time for the electrode and ATC/Temp probe to stabilize before taking any action. 1.4 Remove the ph electrode and ATC/Temp probe from buffer 7.00 (or 6.86) and rinse both in distilled water. After rinsing, immerse both in buffer 4.00(4.01) or 9.18(10.01) ph. 1.5 Press the [SLOPE] key. The SLOPE annunciator will stop flashing and stay on. The WAIT annunciator will start to flash, indicating that the instrument is waiting for a stable reading. The display will be 8

locked to the second buffer value corresponding to the temperature of the second buffer. When a stable reading is reached, the WAIT annunciator will stop flashing and stay off. The instrument will calculate and compensate for the ph electrode slope deviation corresponding to the values of the two calibration buffers. The instrument is now dual point calibrated and ready for measurements. After two point calibration, pressing and holding the [MEA./EFF.] key for about 5 seconds will display the new electrode efficiency. 2. Calibration with manual temperature compensation in the ph-autolock mode. 2.1 Connect the ph electrode to the BNC connector of the instrument. The MAN annunciator will be on. Press the [MODE] key if necessary to go to ph-autolock mode. 2.2 Rinse the ph electrode in distilled water and immerse it in buffer 7.00(6.86). Set the instrument to display the temperature of the buffer by pressing the [ ] and [ ] keys. The displayed temperature must be less than 60. 2.3 Press the [STAND] key. The STAND annunciator will be on and the WAIT annunciator will flash. This means that the instrument is waiting for a stable reading. The display will be locked to the buffer value corresponding to the temperature of buffer 7.00 (or 6.86) as set in 2.2. When a stable reading is reached, the WAIT annunciator will stop flashing and stay off. The SLOPE annunciator will start to flash, indicating that the standardization at buffer 7.00(6.86) is 9

completed and the instrument is ready to be sloped at a second buffer. Allow sufficient time for the electrode and ATC/Temp probe to stabilize before taking any action. 2.4 Remove the ph electrode from buffer 7.00 (or 6.86), rinse with distilled water and immerse it in buffer 4.00(4.01) or 9.18(10.01). Set the instrument to the temperature of the 2nd buffer as in 2.2. The displayed temperature must be less than 60. 2.5 Press the [SLOPE] key. the SLOPE annunciator will stop flashing and stay on. The WAIT annunciator will start to flash, indicating that the instrument is waiting for a stable reading. The display will be locked to the value of the second buffer corresponding to the temperature of the second buffer as set in 2.3. When a stable reading is reached, the WAIT annunciator will stop flashing and stay off. The instrument will calculate and compensate for the ph electrode slope deviation corresponding to the values of the two calibration buffers. The instrument is now dual point calibrated and ready for measurements. 3. Calibration with ATC/Temp probe in ph mode. 3.1 Connect the ph electrode to the BNC connector and the ATC/Temp probe to the ATC/Temp connector of the instrument. The ATC annunciator on the LCD will be on. Press the [MODE] key for the LCD to display ph and the AUTOLOCK annunciator to be off. 3.2 Rinse the ph electrode and ATC/Temp probe in distilled water and immerse them in ph buffer 7.00(6.86).the instrument will display the buffer temperature. 3.3 Allow sufficient time for the electrode and ATC/Temp 10

probe to stabilize. Press the [STAND] key. The STAND annunciator will be on and the SLOPE annunciator will flash, indicating that standardization at buffer 7.00 (6.86) is completed and the instrument is ready to be sloped at a second buffer. The instrument will display the buffer value corresponding to the temperature of the buffer 7.00(6.86) as measured in 3.2. If the reading still drifts, repeat 3.3 until a stable reading is obtained. 3.4 Remove the ph electrode and ATC/Temp probe from buffer 7.00(6.86). Rinse them in distilled water and immerse them in buffer 4.00(4.01) or 9.18(10.01). The instrument will display the temperature of the second buffer. 3.5 Allow sufficient time for the ph electrode and ATC/Temp probe to stabilize. Press the [SLOPE] key. The SLOPE annunciator will stop flashing and stay on. The instrument will display the second buffer value corresponding to the temperature of the second buffer, as measured in 3.4. If the reading still drifts, repeat 3.5, until a stable reading is obtained. The instrument will calculate and compensate for the ph electrode slope deviation corresponding to the values of the two calibration buffers. The instrument is now dual point calibrated and ready for measurements. After two point calibration, pressing and holding the [MEA./EFF.] key for about 5 seconds will display the new electrode efficiency. 4. Calibration with manual temperature compensation in the ph mode. 4.1 Connect the ph electrode to the BNC connector of the 11

instrument. The MAN annunciator will be on. Press the [MODE] key for the LCD to indicate ph and for the AUTO annunciator to be off. 4.2 Rinse the ph electrode in distilled water and immerse in buffer 7.00(6.86). Set the instrument to display the temperature of the buffer by pressing the [ ] and [ ] keys. The displayed temperature must be less than 60. 4.3 Allow sufficient time for the electrode to stabilize. Press the [STAND] key. the STAND annunciator will be on and the SLOPE annunciator will start to flash, indicating that the standardization at buffer 7.00 (6.86) is completed and the instrument is ready to be sloped at a second buffer. The instrument will display the buffer value corresponding to the temperature of the buffer 7.00(6.86) set in 4.2. If the reading still drifts, repeat 4.3 until a stable reading is obtained. 4.4 Remove the ph electrode from buffer 7.00(6.86), rinse with distilled water and immerse it in buffer 4.00(4.01) or 9.18(10.01). Set the instrument to the temperature of the 2nd buffer as in 4.2. The displayed temperature must be less than 60. 4.5 Allow sufficient time for the ph electrode to stabilize. Press the [SLOPE] key. the SLOPE annunciator will stop flashing and stay on. The instrument will display the value of the second buffer corresponding to the temperature of the second buffer as set in 4.4. If the reading still drifts, repeat 4.5, until a stable reading is obtained. The instrument will calculate and compensate for the ph electrode slope deviation corresponding to the values 12

of the two calibration buffers. The instrument is now dual point calibrated and ready for measurements. After two point calibration, pressing and holding the [MEA./EFF.] key for about 5 seconds will display the new electrode efficiency. ph MEASUREMENTS The STAND and SLOPE annunciators must be on. This means that the instrument is dual point calibrated and is ready for measurements. 1. Measurement with ATC/Temp probe in the ph-autolock mode. 1.1 Connect the ph electrode and ATC/Temp probe to the connector of the instrument. The ATC annunciator will be on. 1.2 Press the [MODE] key until the LCD indicates ph mode and the AUTO annunciator is on. 1.3 Rinse the ph electrode and the ATC/Temp probe with distilled water and immerse them in the sample to be measured. 1.4 Press the [MEA./EFF.] key. The WAIT annunciator will start flashing. This means the instrument is waiting for a stable reading. The display will track the ph value as sensed by the ph electrode and the ATC/Temp probe. When the display changes less than 0.01 ph in about 10 seconds the autolock function will be activated. The WAIT annunciator will stop flashing and stay off. The reading is then locked and will not respond to further changes from the ph electrode and ATC/Temp probe. 13

1.5 For samples that are inherently unstable, the instrument will not AUTOLOCK. In this case, use the ph NON-AUTOLOCK mode for measurements. 2. Measurement with ATC/Temp probe in the ph NON-AUTOLOCK mode. 2.1 Connect the ph electrode and the ATC/Temp probe to the connector of the instrument. The ATC annunciator will be on. 2.2 Press the [MODE] key for the LCD to indicate ph and for the AUTO annunciator to be off. 2.3 Rinse the ph electrode and the ATC/Temp probe with distilled water and immerse them in the sample to measured. 2.4 Allow sufficient time for the display to stabilize. The instrument will display the ph value of the sample at the displayed sample temperature. 3. Measurement with manual temperature compensation in the ph-autolock mode. 3.1 Connect the ph electrode to the connector of the instrument The MAN annunciator will be on. 3.2 Press the [MODE] key for the LCD to indicate ph and for the AUTO annunciator to be on. 3.3 Rinse the ph electrode with distilled water and immerse it in the sample to be measured. Set the instrument to the temperature of the sample as in 2.2 of ph CALIBRATION section. 3.4 Press the [MEA/EFF.] key. The WAIT annunciator will start to flash. This means that the instrument is waiting for a stable reading. The display will track the ph value as sensed by the ph electrode. When the 14

display changes less than 0.01 ph within approximately 10 seconds, the autolock function will be activated. The WAIT annunciator will stop flashing and stay off. The reading is then locked and will not respond to further changes from the ph electrode. 3.5 For samples that are inherently unstable, the instrument will not autolock. Use the ph NON-AUTOLOCK mode for measurements. 4. Measurement with manual temperature compensation in the ph NON-AUTOLOCK mode. 4.1 Connect the ph electrode to the connector of the instrument. 4.2 Press the [MODE] key for the LCD to display ph and for the AUTO annunciator to be off. 4.3 Rinse the ph electrode with distilled water and immerse it in the sample to be measured. 4.4 Allow sufficient time for the display to stabilize. The instrument will display the ph value of the sample at the set sample temperature. TEMPEARTURE MEASUREMENTS The model 6173 can be used to measure temperature independently with the ATC/Temp probe without using the ph electrode. 1. Place the ATC/Temp probe in the media to be measured. The measured temperature is displayed. 2. If "Undr/OvEr" is displayed on, the temperature is out of the temperature range of -10.0 to 120.. Once the temperature is brought within range, then "Undr/OvEr" will 15

disappear and the correct temperature reading will be displayed. It is not necessary to press the [CLEAR] key. mv MEASUREMENTS 1. Measurement in the mv-autolock mode. 1.1 Connect the optional combination ORP electrode to the BNC connector of instrument. 1.2 Press the [MODE] key for the LCD to indicate mv and for the AUTO annunciator to be on. 1.3 Rinse the electrode with distilled water and immerse it in the sample to be measured. 1.4 Press the [MEA./EFF.] key. The WAIT annunciator will start to flash. This means the instrument is waiting for a stable reading. The display will track the mv value as sensed by the electrode,. When the display changes less than 1 mv within 10 seconds, the AUTOLOCK function will be activated. The WAIT annunciator will stop flashing and stay off. The reading is then locked and will not respond to further changes from the electrode. The lock display is the mv value of the sample. If "OvEr/Undr" is displayed, the mv value measured is out of the -2000/+2000 mv range. The instrument will display the correct value once the input mv is brought within range. It is not necessary to press the [CLEAR]. 1.5 The ATC/Temp probe can be used to measure the sample temperature as required. 16

1.6 For samples that are inherently unstable, the instrument will not autolock. In this case, use the mv NON-AUTOLOCK mode for measurements. 2. Measurement in the mv NON-AUTOLOCK mode. 2.1 Connect an ORP electrode to the BNC connector of instrument. 2.2 Press the [MODE] key for the LCD to indicate mv and for the AUTO annunciator to be off. 2.3 Rinse the electrode with distilled water and immerse it in sample to be measured. 2.4 Allow sufficient time for the display to stabilize. The instrument will display the mv value of the sample. If "OvEr/Undr " is displayed, the mv value measured is out of the -2000/+2000 mv range. The instrument will display the correct value once the input mv is brought within range. It is not necessary to press the [CLEAR]. 2.5 The ATC/Temp probe can be used to measure the sample temperature as required. ph BUFFERS The temperature coefficient of ph calibration buffers 4.00,4.01, 6.86, 7.00, 9.18 and 10.01 are stored inside the instrument. The buffers used to calibrate the instrument must exhibit the same temperature characteristics as the stored values. 17

Temperature coefficient of the ph buffers 4.00 6.86 9.18 4.01 7.00 10.01 0 4.01 6.98 9.46 4.01 7.11 10.32 5 4.00 6.95 9.39 4.01 7.08 10.25 10 4.00 6.92 9.33 4.00 7.06 10.18 15 4.00 6.90 9.28 4.00 7.03 10.12 20 4.00 6.88 9.23 4.00 7.01 10.06 25 4.00 6.86 9.18 4.01 7.00 10.01 30 4.01 6.85 9.14 4.01 6.98 9.97 35 4.02 6.84 9.10 4.02 6.98 9.93 40 4.03 6.84 9.07 4.03 6.97 9.89 45 4.04 6.83 9.04 4.04 6.97 9.86 50 4.06 6.83 9.02 4.06 6.97 9.83 55 4.07 6.83 8.99 4.08 6.97 9.80 60 4.09 6.84 8.97 4.10 6.98 9.78 Note : The actual reading of the instrument can differ from the values shown by ±0.01 ph. SPECIFICATIONS Display Range Accuracy Resolution ph -6.00 to 20.00 ph ±0.01pH,±1digit 0.01 ph mv -2000 to 2000 mv ±0.05%FS,±1digit 1mV Temperature -10.0 to 120 ±0.5 0.1 ph Temp compensation AUTO/MANual -10.0 to 120.0 ph Buffer recognition (4.01,7.00&10.01)or(4.00,6.86,9.18) ph Buffer Temp. range 0 to 60 PH Electrode Offset recognition ±90mV at ph 7.00 or 6.86 ph Electrode Slope recognition ±30% at ph 4.01,9.18 or 10.01 Input Impedance >10 13 Ω Power Supply : Batteries/Adapter Six 1.5V batteries/ac adaptor 18

Battery Life About 500 hours Calibration Back-up EEPROM Audio Feedback All Touch Keys End Point Sensing & Hold Yes LCD Size ( ph/mv : Temp) 16mm : 21 mm high LCD Ambient Temp. Range 0 to 50 Relative Humidity up to 95% ATC Probe Thermistor, 10kΩ RS-232 communication Bate Rate 9600 Dimensions (W x D x H ) 230mm L x 165 mm W x 80 mm H Weight 650 grams (Batteries not included) WARRANTY Jenco Instruments, Inc. warranties the model 6173 for a period of one year, from date of purchase, against all defects in material and workmanship. This warranty does not apply to the abuse and misuse of the instrument. If repair or adjustment is required, please return the defective instrument, freight prepaid. Instrument within warranty period will be repaired at no charge. Please make sure that the instrument is properly packaged and insured against possible damage in shipment. Authorization must be obtained from a Jenco representative before returning items for any reason. 19