Experion LX Direct Station Specification

Similar documents
900 ControlEdge Remote Termination Panel (RTP) For Relay Outputs

STT700 Temperature Transmitter Lightning Protection Device Specifications 34-TT-03-20, June 2017

STT850 and STT750 SmartLine Temperature Transmitter HART Communications Options Safety Manual 34-TT Revision 4 September 2017

Replacing GWR Sensor Electronics

Field Products. Experion LX. Proven DCS for a wide range of industrial applications

SLG 700 SmartLine Level Transmitters Guided Wave Radar Safety Manual 34-SL Revision 4.0 December 2017

SAFETY MANAGER SC Ensure safety, simplify operations and reduce lifecycle costs

SmartLine Pressure Transmitter ST 700 Basic Quick Start Installation Guide 34-ST-25-57, Revision 1, December 2016

CompleteView Alarm Client User Manual. CompleteView Version 4.6.1

System Description AutroMaster V Presentation System

Moxa Proactive Monitoring User s Manual

Process Measurement & Control. Experion HS. A New Level in Operational Excellence

SmartLine. RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December Technical Information.

2015 Honeywell Users Group Europe, Middle East and Africa

Protect your investment with Safety Manager

Samsung SDS BMS Ver.2.0. Technical Specification

DATA SHEET BENEFITS CURRENT CHALLENGES SSM INFOTECH S X-FORCE AMS - THE IDEAL SOLUTION

Architectural and Engineering Specification for a Security Management System. StarNet 2

2013 Honeywell Users Group Americas. Joe Bastone. Experion PKS Slick Tricks

Process Solutions. Solution Note. HC900 and OneWireless. Background. Applications. Key issues. Tanks in explosion-proof areas.

Protect your Investment with Safety Manager R160 and Integrated Fire and Solutions

Station Planning Guide

EX41922-T Hardened Unmanaged 2-port 10/100/1000BASE PoE + 2-port 100/1000 SFP Ethernet Switch. User s Guide

Supervisor Standard Edition

Complexity made simple

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Embedded Linux with VAR-SOM-MX6 Course

Compact HMI Overview

Field Products. Apeldoorn Flexible Packaging BV, Netherlands Uses Honeywell s HC900, Experion HS and MXProLine to Improve Stretch Foil Quality

EX41922 Hardened Unmanaged 2-port 10/100/1000BASE + 2-port 100/1000 SFP Ethernet Switch. User s Guide

DynAMo Alarm & Operations Management

Patriot Systems Limited

HMI of the Future with Experion Orion Console and Experion Collaboration Station Andrew Stuart & Annemarie Diepenbroek, Honeywell

Patriot Systems Limited

ONYX FirstVision Specification Interactive Firefighters Display

Dolphin 9900 Mobile Computer

Thermal Solutions SLATE TM. Dual Burner Applications: Tech Features

Compact Product Suite Compact HMI 6.0 Overview ABB

HikCentral Web Client. User Manual

2013 Honeywell Users Group Europe, Middle East and Africa. Erik de Groot. Safety and Fire & Gas Solutions

Section PERIMETER SECURITY SYSTEMS

Datasheet Video Based Fire & Smoke Detection

Simplex Panel Interface Guide

HikCentral Web Client. User Manual

Perimeter Product Overview. Effective protection for your business

Dynamic Solutions. Endless Possibilities. Steve Padasack, Finch Paper LLC Rick Van Fleet, Honeywell

Technical Publications. FactoryTalk Alarms and Events System Configuration Guide

Connected Plant. SMARTLINE TRANSMITTERS So Smart, They Make Life Easy

BlackBerry AtHoc Networked Crisis Communication Siemens Indoor Fire Panel Installation and Configuration Guide Release Version 7.

BIS - Overview and basic package

VIDEO SURVEILLANCE MARKET

Improving the Performance of Power Plants Worldwide

ThermoControl 0 C - 10 C - 20 C - 30 C

Gerrie Benjert 26 September INTEGRATED TERMINAL AUTOMATION Safety, Security and Operations

IS-4500 TCP/IP Video Door Phone System

Secure Your Way of Life. Now Compa ble With. Climax Home Portal Platform. Enable a Connected Future

Modbus TCP/IP Option Instruction Manual

Transform TDC 2000 Data Hiway to Experion PKS While Retaining Graphics, Applications and Wiring Jazeem Mohammed, Honeywell

Product Brief for Alarm Analytics V9.2 April 2010

Gallagher Perimeter Product Overview

IS IP Video Door Phone. FEATURES

FactoryTalk Alarms and Events. System Configuration Guide

Recording Server PRELOADED

Andrew Brodie 26 September 2017 DISCOVER THE FASTER AND SCALABLE VERSION OF THE ENHANCED CONTROLEDGE HC900 FOR A SAFE AND PROFITABLE PLANT

LightSweep. Lighting Control System

Facility Explorer Asset Protection by Yorkland Controls Ltd. Fr

P2000 and Metasys System Integration

Hardware and Software Requirements. Integration Enhancements. Functional Enhancements

Datasheet. Version 3.8. License Plate Recognition + Red Light Violation Detection. Datasheet LPR + RLVD Version

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

Ademco Vista Alarm Panel

Total Unified Solution for Building Integration: Communications, Access Control, Video Surveillance and Fire

Intelligent alarm management

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel

EnergyMaster. ENEC Monitoring System. An on-site supervision and remote monitoring solution

RMA 3000 Remote Meter Assemblies

Duct Mount. Installation Instructions

TPS Virtualization and Future Virtual Developments Paul Hodge, Honeywell

Oracle Retail Merchandise Financial Planning

PotterNet Fire & Facility Supervising Station

Architecting a Distributed FactoryTalk View SE Application

Honeywell Users Group Where Technology Shapes Solutions. Jeff Spaulding UIS Customer Co-Chair

Product Brief for Alarm Analytics V9.3 October 2013

Field Products. Solutions for Improved Thermal Process Performance

For Complete Fire and Gas Solutions

Daily Offsite; 30 days of backup available; Offsite Annual backup maintained for 5 years

Alarm Coordination Connected Components Building Block. Quick Start

DATAssure. Laboratory wireless alarm & monitoring system

Before you install ProSeries Express Edition software for network use

PRO-WATCH NOTIFIER SECONDARY FIRE INTERFACE ARCHITECT AND ENGINEERING SPECIFICATION

NETWORKING AND INTEGRATION

Manual# User s Manual. 200 Series. DCU 210/208 Diesel Engine Control Unit RP 210 Remote Panel

Terminal Automation Solutions SmartRadar FlexLine Global Experience. Locally Applied.

Advanced Facility Air-Management Technology

ARES-G2 Rheometer. Site Preparation Guide. Revision A Issued June 2016 Page 1

P2000 and Metasys System Integration

DeltaV Operate. Product Data Sheet DeltaV Operate December 2006 Page 1. Introduction. Benefits

Certified Solution for Milestone

Different types of Fire Alarm System

Dräger VVP 1000 System Components

Transcription:

Technical Information Experion LX Direct Station Specification LX03-210-110 Release 110 January 2014, Version 1

Experion LX Station Specification, LX03-210-110 Revision History Revision Date Description 1.0 January 2014 Release publication

Experion LX Station Specification, LX03-210-110 Table of Contents 1. Product Introduction... 1 1.1. Experion LX System... 1 1.2. Architecture Overview... 1 1.3. Experion LX Direct Station Overview... 2 2. Specifications... 2 2.1. Station Sizing... 2 3. Hardware and Software Requirements... 3 3.1. Experion LX Station Computer Requirements... 3 4. Model Numbers... 4 4.1. LX Station Software... 4 4.2. LX Station Hardware... 4 5. Glossary... 5

Experion LX Direct Station Specification, LX03-210-110 1 1. Product Introduction 1.1. Experion LX TM System As a member of Honeywell s Experion family, Experion LX is specifically designed to meet the customer needs in midtier markets (Chemicals, Industrial Power, F&B, Bio-fuels, ), through integrating state-of-the-art technology from the award-winning Experion Process Knowledge System (PKS) with innovative design of Series 8 I/O modules and cabinets, validated wider range of COTS options, easier engineering and maintenance capabilities, and integrator-friendly programs and tools. Experion LX is the perfect platform for process, asset and business management, and enables customers to increase their profitability, productivity and accessibility to local support without sacrificing quality and reliability in an increasingly competitive environment. 1.2. Architecture Overview The Experion LX platform comprises many different integrated hardware and software solutions depending upon the needs of the installation. The pictured architecture is a representation of many of the possible nodes that can be used in the Experion LX architecture. Note that the architecture is highly scalable and not all nodes are necessary or required. Figure 1- Sample Experion LX architecture

Experion LX Direct Station Specification, LX03-210-110 2 1.3. Experion LX Direct Station Overview The Experion LX Direct Station is the human-machine interface (HMI) that can be used for different functions around a plant including operations, monitoring, maintenance and engineering. The Direct Station is connected to process controller and can directly access process data, alarms, and messages from C300 and so on. There is no loss of view of critical data and alarms when the server fails and therefore an operator can still control and monitor the process, which is helpful in an environment where continuity of view is paramount and where it is important to minimize the impact of a server being unavailable. Direct Station is connected to the Experion LX Server for communication to SCADA and DSA point sources, system history, the system event journal, and the system configuration file server. The Direct Station supports the implementation of a logical console. This allows operators to fully respond to all alarms/events within their scope of responsibility regardless of operator actions on other stations; providing a single work space for an operator for event handling, alarm acknowledgement, alarm silencing, display manipulation and other functions. 2. Specifications 2.1. Station Sizing For the standard capacity system, the maximum number of supported Direct Stations for each system is 10, while for high capacity system, the limit is 15. Station Display Performance Specifications Specification Display Parameters Maximum number of dynamic parameters per display 600 Maximum number of parameters per second (PPS) per Station computer 1 1000 Maximum number of dynamic parameters per Station Computer 1200 Maximum number of windows per station computer (includes all status, command, graphic and faceplate windows) Maximum number of concurrent faceplates per station computer 8 Display Updates Maximum Display Update Rate 4 Typical Field Change to Display Update Time with 600 or less Parameters per Display 4 1 second < 2 seconds Typical complex Display Call Up Time with 300 or less Parameters 2, 3 Typical complex Display Call Up Time with 600 or less Parameters 2, 3 Standard Faceplate Call Up Time < 1.5 seconds < 2 seconds < 2 seconds Note 1 - When greater that 1000 Dynamic Parameters are configured, the update rate must be greater than 1 sec. to not violate max PPS Note 2 - Call up time is dependent on display complexity; a non-complex graphic uses standard HMIWeb Display Builder objects with limited use of scripts; this excludes the first initial call up. Note 3 - Complex displays include the number of data bound objects identified, large amount of total objects on the display, and a significant amount of scripting.; includes custom faceplates and popups; assumes performance platform; this excludes the first initial call up Note 4 - Display update values are specified for performance systems and in some cases may not be met by lower specification equipment

Experion LX Direct Station Specification, LX03-210-110 3 3. Hardware and Software Requirements 3.1. Experion LX Station Computer Requirements A computer must meet the following specifications to be used as a Experion LX Station. These guidelines are intended to provide a minimum baseline. Honeywell computer platforms meet these specifications but may not necessarily be the example platforms listed below. It s highly recommended that user select Honeywell qualified computers to avoid potential incompatibility. For installation information on computer platforms, including physical, electrical, corrosion, and other environmental requirements, please consult the Honeywell installation guides. This platform specification is based on typical use of the system. To achieve satisfactory performance additional RAM or a higher performance CPU may be required in the following circumstances: If the recommended number of data bound objects per display or per station is exceeded Third party applications are used When purchasing a new platform or adding memory to an existing platform the strong recommendation is to use the maximum supported memory. This will provide optimal performance and could avoid the need to add more memory in the future. Direct Station Requirements System Configuration Processor RAM 1 Networking 2 Video memory (VRAM) Operating system Minimum Intel Core i3-2120, 3.30GHz (or better) 3 GB 100 Mbps FTE 64 MB Windows 7 Professional (32-bit) un English Browser type Microsoft Internet Explorer 8 Hard drive 160 GB (IDE/ATA) Example platforms EA-PCDEE3 (based on Dell 3010) Note 1 An additional 1GB of RAM is suggested for enhanced performance if the Control Builder client is used. Note 2 For controllers, Direct Stations can only communicate directly with devices that reside in the same FTE Community.

Experion LX Direct Station Specification, LX03-210-110 4 4. Model Numbers 4.1. LX Station Software Model Number CV-STAD01 Description Experion LX Direct Station (1 connection) 1 Direct Station license is provided with the Experion LX base software license. 4.2. LX Station Hardware Description Dell 3010 HP Compaq 6305pro Network card Broadcom 5720 Network card Intel 82576 Display card HD6670-2GD3

Experion LX Direct Station Specification, LX03-210-110 5 5. Glossary Term or Acronym C300 CDA DCS DSA Experion LX Server FTE GUS HMI HMIWeb HTML Icon Series IKB pps SCADA Description A specific type of Honeywell Process Controller based on the series C form factor Control Data Access is the LX Station system communication infrastructure and data access interface schema that provides application integration with LX Station system objects. Distributed Control System Distributed System Architecture The node (optionally redundant) at the heart of Experion LX. The server encompasses a wide range of subsystems including history collection, SCADA interfaces, alarm/event, etc. Fault Tolerant Ethernet, the Experion LX control network Global User Station Human-machine interface Human-machine interface based on Web technology HyperText Markup Language Flat screen technology hardware console Integrated Keyboard Parameters per second Supervisory control and data acquisition

Experion TM and Experion LX are trademarks of Honeywell International Inc.. All other products and brand names shown are trademarks of their respective owners. This document contains Honeywell proprietary information. It is published for the sole usage of Honeywell Process Solutions customers and prospective customers worldwide. Information contained herein is to be used solely for the purpose submitted, and no part of this document or its contents shall be reproduced, published, or disclosed to a third party without the express permission of Honeywell International Inc.. While this information is presented in good faith and believed to be accurate, Honeywell disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer. In no event is Honeywell liable to anyone for any indirect, special or consequential damages. The information and specifications in this document are subject to change without notice.

Sales and Service For application assistance, current specifications, pricing, or name of the nearest Authorized Distributor, contact one of the offices below. ASIA PACIFIC Honeywell Process Solutions, (TAC) hfs-tacsupport@honeywell.com Australia Honeywell Limited Phone: +(61) 7-3846 1255 FAX: +(61) 7-3840 6481 Toll Free 1300-36-39-36 Toll Free Fax: 1300-36-04-70 China PRC - Shanghai Honeywell China Inc. Phone: (86-21) 5257-4568 Fax: (86-21) 6237-2826 Singapore Honeywell Pte Ltd. Phone: +(65) 6580 3278 Fax: +(65) 6445-3033 South Korea Honeywell Korea Co Ltd Phone: +(822) 799 6114 Fax: +(822) 792 9015 EMEA Honeywell Process Solutions, Phone: + 80012026455 or +44 (0)1344 656000 Email: (Sales) FP-Sales-Apps@Honeywell.com or (TAC) hfs-tac-support@honeywell.com AMERICA S Honeywell Process Solutions, Phone: (TAC) 1-800-423-9883 or 215/641-3610 (Sales) 1-800-343-0228 Email: (Sales) FP-Sales-Apps@Honeywell.com or (TAC) hfs-tac-support@honeywell.com Specifications are subject to change without notice. For more information To learn more about Experion, visit www.honeywellprocess.com Or contact your Honeywell Account Manager Process Solutions Honeywell 1250 W Sam Houston Pkwy S Houston, TX 77042 Honeywell Control Systems Ltd Honeywell House, Skimped Hill Lane Bracknell, England, RG12 1EB Shanghai City Centre, 100 Jungi Road Shanghai, China 20061 www.honeywellprocess.com LX03-210-110, Ver.1 January 2014 2014 Honeywell International Inc.