STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

Similar documents
STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

standard/quick response extended coverage light and ordinary hazard elo sprinklers

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

EC/QREC ORDINARY HAZARD UPRIGHT SPRINKLER VK570 (K14.0) TECHNICAL DATA

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK534 (K11.2)

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

standard response Fusible Link Upright sprinkler VK204 (K8.0)

TECHNICAL DATA. Refer to Approval Chart 1 and FM Design Criteria for FM Approval requirements that must be followed.

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

standard response elo upright sprinkler

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

TECHNICAL DATA OBSOLETE

Microfast quick response Fusible element hsw sprinkler

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

microfast sr/qr extended coverage pendent sprinkler

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

standard response fusible link sidewall sprinkler VK112 (K5.6)

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

STANDARD/quick. Sprinkler 42o. August 8, 2011

MIRAGE EC/QREC OH-ELO CONCEALED PENDENT SPRINKLER VK538 (K11.2) TECHNICAL DATA

sprinkler vk538 (K11.2)

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

microfast quick response extended coverage hsw sprinkler vk606

MICROFAST SR/QR EXTENDED COVERAGE HSW SPRINKLER VK605 (K5.6) TECHNICAL DATA

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

standard response elo upright and pendent sprinklers (storage-density/area)

micromatic Standard response Horizontal Sidewall sprinkler

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

standard response/ quick response extended coverage

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

TECHNICAL DATA. Page 1 of 6

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

micromatic standard response Upright sprinkler VK100 (K5.6)

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK118 (K5.6) TECHNICAL DATA

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

TECHNICAL DATA. The Web site may include a more recent Frame Casting: Brass UNS-C84400

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

microfast and microfasthp quick conventional sprinklers

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK3311 (K4.2) TECHNICAL DATA

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

TECHNICAL DATA. Page 1 of 5

microfast quick response Pendent sprinkler VK302 (K5.6)

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

quick response Sprinkler 105a October 25, 2010

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

standard response large orifice dry

quick response horizontal sidewall sprinkler vk360 (K8.0)

micromatic standard response stainless steel sprinklers

Standard Spray concealed horizontal sidewall sprinkler VK481

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

micromatic Standard response Horizontal Sidewall sprinkler

MICROMATIC STANDARD RESPONSE PENDENT SPRINKLER VK102 (K5.6) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

MICROMATIC STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK104 (K5.6) TECHNICAL DATA

VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) TECHNICAL DATA

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK120 (K8.0) TECHNICAL DATA

standard response dry horizontal sidewall sprinklers

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

HORIZON MIRAGE QUICK RESPONSE LARGE ORIFICE CONCEALED PENDENT SPRINKLER VK406 TECHNICAL DATA

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

MicrofastHP QUICK RESPONSE HORIZONTAL SIDEWALL HIGH PRESSURE SPRINKLER VK319 (K5.6) TECHNICAL DATA

standard response dry horizontal sidewall sprinklers

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

QUICK RESPONSE DRY CONCEALED PENDENT SPRINKLER VK194 TECHNICAL DATA

quick response sprinkler vk194 Sprinkler 104j January 1, 2011

DRY VERTICAL SIDEWALL SPRINKLERS TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA

standard response dry horizontal sidewall sprinklers

Quick response concealed horizontal sidewall sprinkler VK481

TECHNICAL DATA. Viking Technical Data may be found on Minimum Operating Pressure: Refer to the Approval Chart.

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK457 (K4.9) TECHNICAL DATA

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. 2. LISTINGS AND APPROVALS NOTE: Viking Dry Vertical Sidewall Sprinklers are NOT listed or approved. Sprinkler 103a.

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA

Transcription:

Page of 5. DESCRIPTION Viking EC/QREC Ordinary Hazard ELO Fusible Element Sprinkler VK535 is a thermosensitive spray sprinkler available in several different finishes and temperature ratings to meet varying design requirements. The extra-large orifice produces the flows required to meet Ordinary Hazard density requirements at lower pressures than standard orifice or large orifice sprinklers. Upright Sprinkler VK535 is UL Listed as standard response and FM Approved as quick response. The special Polyester and PTFE coatings can be used in decorative applications where colors are desired.. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 0 Refer to Approval Chart and UL Design Criteria for culus Listing requirements, and refer to Approval Chart and FM Design Criteria for FM Approval requirements that must be followed. culus Listing requires the spacing between upright VK535 sprinklers to be a minimum of 3 ft. (4 m) to prevent cold soldering. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: Refer to the Approval Charts. Maximum Working Pressure: 75 psi ( Bar). Factory tested hydrostatically to 500 psi (34.5 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 3/4 (0 mm) NPT Nominal K-Factor:. U.S. (6.3 metric ) Metric K-factor measurement shown is in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 0.0. Overall Length: -5/6 (59 mm) Material Standards: Sprinkler Frame: Brass UNS-C84400 Deflector: Copper UNS-C9500 for Sprinkler Fusible Element Assembly: Nickel Alloy Trigger and Support: Stainless Steel UNS-S3600 Seat and Insert Assembly: Copper UNS-C000 and Stainless Steel UNS-S30400 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Viking Technical Data may be found on The Viking Corporation s Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Order EC/QREC Ordinary Hazard ELO Fusible Element Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and Black PTFE = N Temperature Suffix ( F/ C): 65 /74 = C and 05 /96 = E For example, sprinkler VK535 with a Brass finish and a 65 F/74 C temperature rating = Part No. 439AC Available Finishes And Temperature Ratings: Refer to Table. Accessories: (Also refer to the Sprinkler Accessories section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 058CW/B (available since 98) Sprinkler Cabinets: A. Six-head capacity: Part No. 074A (available since 97) B. Twelve-head capacity: Part No. 075A (available since 97) (New page for VK535)

Page of 5 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive fusible element assembly disengages, releasing the seat and spring assemblies to open the waterway. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 5 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler VK535 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking s current list price schedule or contact Viking directly. Protective Sprinkler Clip Wrench Flat Figure : Standard Sprinkler Wrench 058CW/B Sprinkler Temperature Classification TABLE : AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Nominal Temperature Rating Maximum Ambient Ceiling Temperature Frame Paint Color Ordinary 65 F (74 C) 00 F (38 C) None Intermediate 05 F (96 C) 50 F (65 C) White High 80 F (38 C) 5 F (07 C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester 3, Black Polyester 3, and Black PTFE 3 Decorative sprinklers may not be color coded. The temperature rating is stamped on the deflector. Based on NFPA-3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and PTFE coatings. For PTFE coated open sprinklers only, the waterway is coated.

Page 3 of 5 Sprinkler Base Part Number SIN Approval Chart (UL) EC/QREC Fusible Element Ordinary Hazard ELO Sprinkler VK535 NPT Thread Size Nominal K-Factor Maximum Water Overall Length Inches mm U.S. metric Working Pressure Inches mm 439 VK535 3/4 0. 6.3 75 psi ( Bar) -5/6 59 Maximum Sprinkler Spacing (L x W 5 ) 6 ft. x 6 ft. (4.9 m x 4.9 m) 8 ft. x 8 ft. (5.5 m x 5.5 m) 0 ft. x 0 ft. (6. m x 6. m) 4 ft. x 4 ft. (4.3 m x 4.3 m) Maximum Area per Sprinkler 56 ft (3.8 m ) 34 ft (30. m ) 400 ft (37. m ) 96 ft (8. m ) Minimum Water Supply Requirements 5 Listings and Approvals 3 Ordinary Hazard Group I Ordinary Hazard Group II (See Design Criteria.) Flow / Pressure Flow / Pressure culus 4 NYC 38 gpm @.5 psi (43.9 L/min @.79 Bar) 49 gpm @ 9. psi (85.5 L/min @.3 Bar) 60 gpm @ 8.7 psi (7. L/min @.98 Bar) 30 gpm @ 7. psi (3.6 L/min @.50 Bar) Standard Response 5 gpm @ 0.7 psi (93. L/min @.43 Bar) 65 gpm @ 33.7 psi (46. L/min @.3 Bar) 80 gpm @ 5.0 psi (30.8 L/min @ 3.5 Bar) Quick Response (culus only) 39 gpm @. psi (47.7 L/min @.84 Bar) Approved Temperature Ratings A - 65 F (74 C) and 05 F (96 C) B - 65 F (74 C) Approved Finishes - Brass, Chrome, White Polyester, Black Polyester, and Black PTFE Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 0.0. 3 This chart shows listings and approvals available at time of printing. Check with the manufacturer for any additional approvals. 4 culus Listed for use in the U.S. and Canada. 5 To determine Minimum Water Supply Requirement for areas of coverage where length and width of actual sprinkler spacing are not equal, select the Maximum Sprinkler Spacing from the chart that is equal to or greater than the larger of the actual spacing (length or width) dimensions used. Example: When using 0-6 x 3-0 sprinkler spacing, provide the Minimum Water Supply Requirement listed in the chart for 4-0 x 4-0 spacing. For areas of coverage smaller than shown, use the Minimum Water Supply Requirement in the appropriate hazard group for the next larger area listed. The distance from sprinklers to walls shall not exceed one-half the Maximum Sprinkler Spacing listed for the Minimum Water Supply Requirement used. 6 Meets New York City requirements, effective July, 008.

Page 4 of 5 DESIGN CRITERIA - UL (Also refer to Approval Chart.) culus Listing Requirements: ECOH-ELO Fusible Element Upright Sprinkler VK535 is culus Listed as indicated in Approval Chart for installation in accordance with the latest edition of NFPA 3 for extended coverage upright sprinklers as indicated below: The minimum water supplies and maximum areas of coverage shown in the Approval Chart are designed to provide the following design densities: 0.5 gpm/ft (6. mm/min) for Ordinary-Hazard Group I densities; 0. gpm/ft. (8. mm/min) for Ordinary-Hazard Group II densities. The sprinkler installation rules contained in NFPA 3 for extended coverage upright and pendent spray sprinklers must be followed with the exception that culus Listing requires the spacing between upright VK535 sprinklers to be a minimum of 3 ft. (4 m) to prevent cold soldering. Viking ECOH-ELO Fusible Element Upright Sprinklers are culus Listed for use in unobstructed construction, and noncombustible obstructed construction consisting of solid steel and/or concrete beams as defined in the latest edition of NFPA 3. Ceiling slope not to exceed / (9.5 ). Also, Viking ECOH-ELO Upright Sprinkler VK535 is specifically culus Listed for: For non-combustible obstructed construction within trusses or bar joists having non-combustible web members greater than (5.4 mm) when applying the 4 times obstruction criteria rule as defined in NFPA 3 under Obstructions to Sprinkler Discharge Pattern Development. For installation under concrete tees when installed as follows:. The stems of the concrete tee construction must be spaced between 3 ft (0.9 m) and 7 ft-6 in (.3 m) on center. The depth of the concrete tees must not exceed 30 in (76 mm). The maximum permitted concrete tee length is 3 ft (9.8 m). However, where the concrete tee length exceeds 3 ft (9.8 m), non-combustible baffles, equal in height to the depth of the tees, can be installed so that the space between the tees does not exceed 3 ft (9.8 m).. The sprinkler deflector is to be located in a horizontal plane at or above (5.4 mm) below the bottom of the concrete tee stems. 3. When the sprinkler deflector is located higher than a horizontal plane (5.4 mm) beneath the bottom of the concrete tee stems, the obstruction to sprinkler discharge criteria requirements of NFPA 3 for extended coverage upright sprinklers applies. IMPORTANT: Always refer to Bulletin Form No. F_09699 - Care and Handling of Sprinklers. Also refer to pages EC-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable.

Page 5 of 5 Maximum Sprinkler Spacing (L x W ) Approval Chart (FM) Quick Response Extended Coverage ELO Upright Sprinkler VK535 For HC-, HC-, and HC-3 Occupancies Maximum 75 PSI ( Bar) WWP Maximum Area per Sprinkler Refer to Design Criteria below. FM Approval ft. x ft. (3.7 m x 3.7 m) 44 ft (3.4 m ) NOTE: FM installation guidelines may differ from culus and/or NFPA criteria. Refer to the 4 ft. x 4 ft. (4.3 m x 4.3 m) 96 ft (8. m ) latest applicable FM Loss Prevention 6 ft. x 6 ft. (4.9 m x 4.9 m) 56 ft (3.8 m ) Data Sheets (including -0 and 3-6). Approved Temperature Ratings A - 65 F (74 C), 05 F (96 C), and 80 F (38 C) Approved Finishes - Brass, Chrome, White Polyester, and Black Polyester This chart shows the FM Approvals available at time of printing. Check with the manufacturer for any additional approvals. To determine Minimum Water Supply Requirement for areas of coverage where length and width of actual sprinkler spacing are not equal, select the Maximum Sprinkler Spacing from the chart that is equal to or greater than the larger of the actual spacing (length or width) dimensions used. Example: When using 0-6 x 3-0 sprinkler spacing, provide the Minimum Water Supply Requirement listed in the chart for 4-0 x 4-0 spacing. For areas of coverage smaller than shown, use the Minimum Water Supply Requirement in the appropriate hazard group for the next larger area listed. The distance from sprinklers to walls shall not exceed one-half the Maximum Sprinkler Spacing listed for the Minimum Water Supply Requirement used. FM Approval Requirements: DESIGN CRITERIA - FM (Also refer to Approval Chart above.) Sprinkler VK535 is FM Approved as a quick response Non-Storage extended coverage upright sprinkler as indicated in the FM Approval Guide for use in occupancy hazard classifications HC-, HC-, and HC-3. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheets -0 and 3-6). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from culus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_09699 - Care and Handling of Sprinklers. Also refer to page EC-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. (New page for VK535)