Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

Similar documents
BUILDING CODE OF AUSTRALIA Section J ASSESSMENT REPORT For DA lodgement

AHRI Certification Program Scopes - COOLING

HVAC Mandatory Provisions Part II, Page 1

MECHANICAL SERVICES 101. Ian White

COMcheck Software Version Review Mechanical Compliance Certificate

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

August 15, 2013 Page 1 of 19

21. Plumbing fixture mixing valves, PRV, electronic faucets and flush valve(excluding batteries)optional Cost proposal to include these device

DOCUMENT TABLE OF CONTENTS

Chilled Water system

Heat pump and energy recovery systems

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

2009 IECC Commercial Mechanical Requirements

"This is only the scope of work for the project. For more information, interested parties should contact Procurement at

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

SECTION/SUBSECTION (scroll down to view more listings; this list is arranged alphabetically) SCOPE. AHRI Section-Subsection Scopes

Practice Advisory 18: Fire safety design for tall buildings

COMcheck Software Version Mechanical Compliance Certificate

NES. What s New June Contents: Detailed Technical guidance. Work section updates. (key points)

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

Inspection Phase Three. Mechanical, Electrical & Plumbing Section 503

AHRI Product Section and Subsection Scopes

Sequence of Operations (excerpt)

Appendix 13. Categories of Cooling and Heating systems

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

PRODUCT RANGE: ROOFTOP PACKAGE

DIVISION 15 MECHANICAL

Shippensburg University

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Operating Performance

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

SUBJECT: Effective Date: Procedure Number:

Energy-Efficiency Measures List

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT

Summary Comparison of Simulation Program Features

IMC Significant Changes Summary Tier I

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

DUCT SYSTEMS CHAPTER 6

Ventilation for New Low-Rise Residential Buildings July 20, 2015

Application of the 2012 North Carolina Energy Conservation Code

RE: Phase 2 Improvements DATE: July 1, 2016 New Administration Building Wernle Youth & Family Treatment Center 2000 Wernle Road Richmond, Indiana

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

V4 15JUNE2016 (COPYRIGHT: DEPARTMENT OF INDUSTRY)

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC

COMMERCIAL ENERGY EFFICIENCY

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

COMMISSION REGULATION (EU) No /.. of

2. CURRICULUM. Sl. No.

PRE-PRINT APPENDIX E GREEN MECHANICAL CODE SUPPLEMENT

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Assessment Schedule - TS8

RSES Technical Institute Training Manual 3 72 hours, 72 NATE CEHs, 7.2 CEUs

COMcheck Software Version Mechanical Compliance Certificate

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Vicot Air Conditioning Co., Ltd. CONTENT

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Appendix A. Glossary of Common Terms

2009 Washington State Non-Residential Energy Code Scott Rushing, PE, LEED AP - Rushing Company Lisa Rosenow, CSBA, LEED AP NEEC

The products covered by the Regulation can be classified as follows:

2011 Manitoba Energy Code for Buildings (MECB) PART 5, Heating, Ventilating and Air-conditioning Systems

SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION)

b.) Technical Information:

Challenges and Methods of Estimating a Conceptual HVAC Design

Summary of BBS Proposed Ohio Mechanical Code Rule Changes October 2016

HVAC Fundamentals & Refrigeration Cycle

HVAC Water chiller selection and optimisation of operation

CHAPTER 4. HVAC DELIVERY SYSTEMS

COMMERCIAL HVAC EQUIPMENT Coils: Direct Expansion, Chilled Water, and Heating

LEED for Homes V4 Provisional Alternative Compliance Paths for the Canadian market March, 2017

CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL BURNING EQUIPMENT

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

Product Section and Subsection Scopes

Energy Efficiency Requirements for Air Conditioners, Chillers and Close Control Units

COMMERCIAL PERMIT APPLICATION AND CHECKLIST. Depending on the scope of your project, the following submittal requirements will apply:

.2 Section Waste Management and Disposal.

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2000 EDITION

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

"This is only the scope of work for the project. For more information, interested parties should contact Procurement at

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below)

TEXTILE AIR ENGINEERING EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

Large AC units using a variety of low-gwp options

Fans and Pumps I. Dr. Sam C. M. Hui Department of Mechanical Engineering The University of Hong Kong

UNIT 4: REFRIGERATION PRINCIPLE

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

FULL AND LEGAL NAME OF CORPORATE ENTITY

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Refrigeration Technology in Building Services Engineering

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

CARE GUIDANCE. Local Exhaust Ventilation (LEV) Systems for High Temperature Insulation Wool (HTIW) LEVEL 2 RECOMMENDATIONS ON BEST PRACTICE

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units.

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

1 - This title will copy onto other forms Date

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Analysis of Changes for the 6 th Edition (2017) Florida Codes

Transcription:

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems If you're a designer or a BCA, this guidance on the energy efficiency of HVAC systems in commercial buildings may be useful. It also contains technical information on ductwork insulation and sealing, and insulating piping, vessels, heat exchangers and tanks. Published on 1 August 2011 2nd edition Of interest to Building consent authorities, Designers ISBN: 978-0478-38115-3 (Online) Introduction H1.3.6 HVAC systems must be located, constructed, and installed to (a) limit energy use, consistent with the intended use of space; and (b) enable them to be maintained to ensure their use of energy remains limited, consistent with the intended use of space. H1.3.6 only applies to buildings that are classified as commercial (refer NZBC clause A1 for definitions). This is not a compliance document and the decision of whether a design complies with clause H1.3.6 is for the BCA to make. Page 1 of 9

Controls HVAC systems should be provided with appropriate controls to enable the achievement of reasonable standards of energy efficiency in use. In normal circumstances, the following features would be appropriate for mechanical heating, cooling, ventilation or air-conditioning system controls: 1.1 The systems should be sub-divided into separate control zones to correspond to each area of the building that has a significantly different solar exposure, or pattern, or type of use. 1.2 Each separate control zone should be capable of independent temperature control, and independent control of ventilation and recirculation rate where the HVAC design provides the ability for such independent control without significant additional control hardware. 1.3 The provision of the service should respond to the requirements of the space it serves. If both heating and cooling are provided to an individual control zone, they should be controlled so as not to operate simultaneously within that zone. 1.4 Central plant should only operate as and when the zone systems require it, except that where noncommunicating controls are used, central plant may be controlled by time schedule and outdoor air temperature such as to minimise plant operation when not needed to satisfy zone requirements. The default condition should be off. 1.5 In addition to these general control provisions, the systems should meet specific control and efficiency standards as provided in the other sections. Air-conditioning and ventilation systems An air-conditioning unit or system should (i) be capable of, where the air-conditioning unit or system has motorised outside air and return dampers, closing the dampers when the air-conditioning unit or system is inactivated (ii) have all conditioned supply-air ductwork insulated in accordance with the suggested Specification H1 where; it passes through an external area, unconditioned space, or zone which is not the final intended destination, and the temperature difference between the ambient air and the supply air is greater than ±5 degrees Celsius at any time (iii) have an outdoor air economy cycle when the unit capacity is over 50 kwr (iv) when the air flow rate is greater than 1000 L/s, be designed so that the total motor shaft power of the fans in Page 2 of 9

the system does not exceed (a) 1 2 W/m for a building of not more than 500 m floor area adjusted by 1.15 W/(L/s) for each increase of 1 (L/s)/m 2 in air flow rate above 10 (L/s)/m 2, and (b) 15 W/m for a building of more than 500 m floor area adjusted by 1.7 W/(L/s) for each increase of 1 (L/s)/m 2 in air flow rate above 9 (L/s)/m2 (v) the suggested requirements of (iv) should not apply to (a) fans in package air-conditioning plant complying with Paragraph 4.3, and (b) the input power for an energy reclaiming system that preconditions outdoor air, and (c) the input power for process-related components such as high efficiency particulate air filters (vi) when serving a conditioned space, not provide mechanical ventilation in excess of the minimum quantity required by NZBC G4 by more than 50% other than where there is (a) additional outside air supplied (b) additional exhaust ventilation needed to balance the required mechanical ventilation; or (c) an energy reclaiming system that preconditions outside air. Smoke and ventilation 2 2 2 2 to provide free cooling, or to balance required exhaust ventilation such as toilet exhaust, or to balance process exhaust such as from a health-care building or laboratory; or The suggested requirements in the Controls and Air-conditioning and ventilation systems sections should not inhibit (i) the smoke hazard management operation of air-conditioning and mechanical ventilation systems; and (ii) essential ventilation (such as for a garbage room, lift motor room, gas meter enclosure or gas regulator enclosure or the like). Heating and chilling systems 4.1 Systems that provide heating or chilling for air-conditioning systems should (i) have any piping, vessels, heat exchangers or tanks containing heated or chilled fluid insulated in accordance with the suggested Specification 2, except those whose insulation levels are covered by Minimum Energy Performance Standards (MEPS), and (ii) where water is circulated by pumping at greater than 2 L/s (a) be designed so that the total of the motor shaft power does not exceed Page 3 of 9

2 2 2 3 W/m for a building of not more than 500 m floor area adjusted by 330 W/(L/s) for each increase of 1 (L/s)/m in water flow rate above 8.6 (L/s) / 1,000 m 2; and 2 2 2 4 W/m for a building of more than 500 m floor area adjusted by 470 W/(L/s) for each increase of 1 (L/s)/m in water flow rate above 10 (L/s) / 1,000 m 2; and (b) except where the pump is required to run at full speed for safe or efficient operation, have the pump capable of varying its speed when it is operating for more than 3,500 hours per year; or is more than 11 kw of motor shaft power; and (iii) if the system contains more than one each of a water heater, chiller or coil used for heating or cooling the building, be capable of stopping the flow of water to non-operating heaters, chillers or coils. 4.2 A water heater, such as a boiler in a heating system for a building, should achieve a minimum thermal efficiency of 80% when gas fired and 78% when oil fired when tested in accordance with BS 7190 or BS 845. A boiler with capacity equal or greater than 500 kw should be fitted with a modulating burner. 4.3 Package air-conditioning equipment, including a split unit and a heat pump, should have an energy efficiency ratio complying with Table 4.3 when tested in accordance with AS/NZS 3823.1.2:1998 at test condition T1. Table 4.3 suggested minimum energy efficiency ratio for packaged air-conditioning equipment Equipment Capacity 65 kwr TO 95 kwr More than 95 kwr TO 125 kwr Suggested minimum energy efficiency ratio Air-conditioner cooling 2.7 2.8 Heat pump cooling 2.6 2.7 4.4 A refrigerant chiller over 125 kwr capacity should have an energy efficiency ratio complying with Table 4.4 when determined in accordance with ARI 550/590. Table 4.4 suggested minimum energy efficiency ratio for refrigerant chillers Suggested minimum energy efficiency ratio Full load Part load Water cooled chiller More than 125 kwr but not more than 525 kwr 4.2 5.2 More than 525 kwr but not more than 1000 kwr 4.5 5.6 More than 1000 kwr 5.5 6.1 Air cooled or evaporatively cooled chiller More than 125 kwr but not more than 525 kwr 2.2 3.0 More than 525 kwr 2.5 3.1 Page 4 of 9

4.5 An air cooled condenser fan motor, other than one that is part of package air-conditioning equipment referred to in Paragraph 4.3, should not use more than 40 W of motor shaft power for each kw of heat rejected from the refrigerant when determined in accordance with ARI 460. 4.6 The fan of a cooling tower should not use more than (i) if a propeller or axial fan, 310 W of motor shaft power for each L/s of cooling water circulated, and (ii) if a centrifugal fan, 590 W of motor shaft power for each L/s of cooling water circulated. 4.7 The fan of a closed circuit cooler should not use more than (i) if a propeller or axial fan, 500 W of motor shaft power for each L/s of cooled fluid circulated; and (ii) if a centrifugal fan, 670 W of motor shaft power for each L/s of cooled fluid circulated. 4.8 The fan of a evaporative condenser should not use more than (i) if a propeller or axial fan, 18 W of motor shaft power for each kw of heat rejected, and (ii) if a centrifugal fan, 22 W of motor shaft power for each kw of heat rejected. 4.9 The spray water pump of a closed circuit cooler or evaporative condenser should not use more than 150 W of pump motor shaft power for each L/s of spray water circulated. Miscellaneous exhaust systems 5.1 A miscellaneous exhaust system with an air flow rate of more than 1000 L/s, that is associated with equipment having a variable demand such as a stove in a commercial kitchen or a chemical bath in a factory, should (i) have the means for the operator to (a)reduce the energy used, such as by a variable speed fan, and (b) stop the motor when the system is not needed, and (ii) be designed to minimise the exhausting of conditioned air. 5.2 The suggested requirements of Paragraph 5.1 above should not apply (i) where additional exhaust ventilation is needed to balance the required outside air for ventilation, or (ii) where air flow must be maintained for safe operation. Access for maintenance At the design and construction stages regard should be given to all requirements of space, position, access and repair (or replacement) in order to commission and maintain the equipment in an efficient operating condition, without undue difficulty, when using normally accepted maintenance procedures. Page 5 of 9

Ductwork insulation and sealing Suggested specification 1 1.1 Scope This Specification contains guidance for sealing and insulating supply and return ductwork used in a system that heats or cools a building. 1.2 Ductwork sealing (a) Heating or cooling ductwork and fittings should be sealed against air loss (i) by closing all openings in the surface, joints and seams of ductwork with adhesives, mastics, sealants or gaskets in accordance with the duct sealing requirements of AS 4254:2002 for the static pressure in the system, or (ii) for flexible ductwork at an operating static pressure of less than 500 Pa, with a sealant and draw band encased with adhesive tape. 1.3 Ductwork insulation (a) Ductwork and fittings for heating or cooling should be thermally insulated with insulation complying with AS/NZS 4859.1:2002 to (i) achieve the Total R-Value specified in Tables 1.3a and 1.3b, or (ii) achieve a minimum Total R-Value of 1.0 for flexible ductwork of not more than 3 m in length from an outlet or the like. (b) Insulation on ductwork conveying cold air should be protected by (i) a vapour barrier on the outside of the insulation, and (ii) overlapping adjoining sheets of the membrane by 50 mm and bonding or taping the sheets together where the vapour barrier is a membrane. (c) Ductwork insulation should (i) be protected against the effects of weather and sunlight, and (ii) abut adjoining insulation to form a continuous barrier, and (iii) be installed so that it maintains its position and thickness, other than at flanges and supports. Page 6 of 9

(d) The suggested requirements of Paragraph 1.3(a) should not apply to heating and cooling ductwork and fittings located within the last conditioned space served. Table 1.3a Ductwork - suggested minimum total R-Value (for systems of no more than 65 kwr and 65 kw heating capacity) Ductwork element Suggested minimum total r-value for ductwork and fittings Evaporative cooling system Heating-only system or refrigerated cooling system Combined heating and refrigerated cooling system Ductwork 0.6 1.0 1.5 (see note) Fittings 0.4 Note: (a) under a suspended floor with an enclosed perimeter; or (b) in a roof space that has insulation of not less than R0.5 directly beneath the roofing. Table 1.3b Ductwork - suggested minimum total R-value (for systems greater than 65 kwr and 65 kw heating capacity) Location of ductwork and fittings Suggested minimum total r-value for ductwork and fittings Evaporative cooling system Heating-only system or refrigerated cooling system Within a conditioned space other than where the space is the only or last space served. Nil 1.3 All other locations 0.9 1.8 Insulating piping, vessels, heat exchangers and tanks Suggested specification 2 This Specification contains guidance for insulating piping, vessels, heat exchangers and tanks containing heated or chilled fluid. The suggested minimum Total R-Value may be reduced by R0.5 for combined heating and refrigerated cooling systems if the ducts are- Page 7 of 9

2.1 Scope This Specification contains guidance for insulating piping, vessels, heat exchangers and tanks containing heated or chilled fluid. 2.2 Insulation (a) Insulation should (i) be protected against the effects of weather and sunlight, and (ii) be able to withstand the temperatures within the piping, and (iii) for piping, achieve the Total R-Value in Table 2.2, and (iv) for vessels, heat exchangers and tanks, achieve a suggested minimum Total R-Value of (A) 2.5 if the content is low temperature brine or glycol, or (B) 1.8 if the content is chilled water, or (C) 1.3 if the content is heated water, or (D) 2.5 if the content is steam. (b) Insulation on piping, vessels, heat exchangers and tanks containing chilled fluid should be protected by a vapour barrier on the outside of the insulation. (c) The suggested requirements of Paragraph 2.2(a) should not apply to heating water piping (i) located within the space being heated where the piping is to provide the heating to that space, or (ii) encased within a concrete floor slab which is part of a floor heating system. Table 2.2 piping - suggested minimum total R-Value Location Suggested minimum total R-Value 1. Heating water piping for systems of no more than 65 kw heating capacity (a) Located internally 0.2 (b) Located within a wall space, an enclosed sub-floor area or an enclosed roof space (c) Located outside the building or in an unenclosed sub-floor area or an unenclosed roof space 0.45 0.6 2. Heating water piping for systems of more than 65 kw heating capacity (a) Located internally 0.6 (b) Located within a wall space, an enclosed sub-floor area or an enclosed roof space (c) Located outside the building or in an unenclosed sub-floor area or an unenclosed roof space 0.7 0.8 Page 8 of 9

3. Cooling water piping for systems of more than 65 kwr capacity but less than 250 kwr capacity (a) Located internally 0.9 (b) Located within a wall space, an enclosed sub-floor area or an enclosed roof space (c) Located outside the building or in an unenclosed sub-floor area or an unenclosed roof space 1.0 1.1 4. Cooling water piping for systems of more than 250 kwr capacity (a) Located internally 1.2 (b) Located within a wall space, an enclosed sub-floor area or an enclosed roof space (c) Located outside the building or in an unenclosed sub-floor area or an unenclosed roof space 1.3 1.4 Note: Piping should be insulated includes flow and return piping, cold water supply piping and pressure relief piping within 500 mm of the connection to the heating or cooling system. This information is published by the Ministry of Business, Innovation and Employment s Chief Executive. It is a general guide only and, if used, does not relieve any person of the obligation to consider any matter to which the information relates according to the circumstances of the particular case. Expert advice may be required in specific circumstances. Where this information relates to assisting people: with compliance with the Building Act, it is published under section 175 of the Building Act with a Weathertight Services claim, it is published under section 12 of the Weathertight Homes Resolution Services Act 2006. Page 9 of 9