JUNE NEWSLETTER- FALLIING OBJECTS

Similar documents
SEPTEMBER-NEWSLETTER-ELEVATOR DANGERS

Fire ground electrocution

PATTERNS OF FIREFIGHTER FIREGROUND INJURIES

Cumru Township Fire Department 4/27/10 Standard Operating Guidelines Page: 1 of 6 Section 15.07

ATTIC FIRES. Part 2 LIGHT SMOKE SHOWING

Wilson County Emergency Management Agency 110 Oak Street Lebanon, Tennessee 37087

Date and Time of Incident. Jan 28, Breakout at 00:55 (approx) Detected at 00:55 Notified by a call to the police station Extinguished by 01:50

ATTIC FIRES. Part 3 HEAVY SMOKE SHOWING

FIREFIGHTER II MANIPULATIVE SKILL OBJECTIVES

Massachusetts FD Fire Fighter Task Survey Analysis Fire Fighter Essential Tasks: COMMONWEALTH OF MASSACHUSETTS FIRE FIGHTER TASK LIST

Provided by Fire Safety Solutions for Oklahomans with Disabilities: A joint project of Oklahoma ABLE Tech & Fire Protection Publications at Oklahoma

Provided by Fire Safety Solutions for Oklahomans with Disabilities: A joint project of Oklahoma ABLE Tech & Fire Protection Publications at Oklahoma

SUBJECT FIRE OPERATIONS GUIDELINE (F.O.G.) #F510 Issued: 1/2014 Last Revision: 1/2014 Pages: 9 By Order Of: J.S. Thompson, Fire Chief

Provided by Fire Safety Solutions for Oklahomans with Disabilities: A joint project of Oklahoma ABLE Tech & Fire Protection Publications at Oklahoma

Rescues individuals in danger from fire, vehicle accidents, industrial accidents and other situation requiring extraction.

Essentials of Fire Fighting, Fourth Edition Transition Guide. Chapter 1: The History of the Fire Service (Essentials, Chapter 1)

Additional Materials: Instructor s PowerPoint, Question Files

Date and Time of Incident. March 10, 1975

DCN: ENGINE COMPANY OPERATIONS CHAPTER 4 March 15, 1997 FIRE SCENE OPERATIONS

Program of Instruction Course Syllabus

AMADOR FIRE PROTECTION DISTRICT

AMADOR FIRE PROTECTION DISTRICT

Travis County Emergency Services District #1 Standard Operating Guidelines

FIREFIGHTER 1 COMPETENCY EVALUATION

Proposed Commercial Project at Plot No. C3A, Sector-16B, Greater Noida West (U.P)

GREEN SHEET. Los Angeles Fire Department. Informational Summary Report of Serious LAFD Injuries, Illnesses, Accidents and Near-Miss Incidents

NYU RESIDENTIAL FIRE SAFETY PLAN PART I - BUILDING INFORMATION SECTION

Based on NFPA 1003: Standard for Airport Fire Fighter Professional Qualifications 2015 Edition

Whitestown Fire Department Standard Operating Procedure

In just two minutes, a fire can become life-threatening. In five minutes, a residence can be engulfed in flames.

BROWNSVILLE VOLUNTEER FIRE DEPARTMENT

2014 Annual Fire Safety Report

ADVANCED EXTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 6 Utilities Electrical Emergencies Revised

FIRE PROTECTION BUREAU ACCREDITATION AND CERTIFICATION PO Box Olympia WA (360) FAX: (360) AIRPORT FIREFIGHTER

Chapter 3 FF II Fire Department Communications

Fire Department Orientation / Organization

Date and Time of Incident. Feb. 13, 1964 Breakout at15:33 (approx.) Noticed at 15:27 Notified by emergency call. Extinguished by 21:07

FIRE SAFETY PLAN PART 1 BUILDING INFORMATION SECTION

American Red Cross: Fire Safety Poll

INTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

Emergency Action Plan for

Safety Manual: Emergency Response

SPEARFISH FIRE DEPARTMENT POLICIES AND PROCEDURES

FIREFIGHTER 1 COMPETENCY EVALUATION

FINAL EXERCISE FIRE AND EXPLOSION SCENARIO

Emergency Action Plan for Sycamore House 3818 Winding Way

Xavier Field Office Emergency Action Plan. For. Xavier Field Office Dana Avenue

Heating Fires in Residential Buildings

Instructor Guide. Title: Tactical Approach to Chimney Fires. Time Required: 2 hours. Materials: PowerPoint presentation AV equipment

Career Fire Fighter Dies While Exiting Residential Basement Fire - New York

HOME FIRE SAFETY. Reference Guide

COMMISSION ON FIRE PROTECTION PERSONNEL STANDARDS AND EDUCATION COMMONWEALTH OF KENTUCKY FIREFIGHTER 2 COMPETENCY EVALUATION

EASTERN ARIZONA COLLEGE Fire Department Operations I

Enactment Date: Rapid Intervention Team and RIT Officer

Rapid Intervention Team

WELDING, CUTTING, AND BRAZING SAFETY PROGRAM

Structural Firefighting Policy

Emergency Action Plan For Alumni Center 1507 Dana Avenue

RAMBLER PARK FIRE SAFETY INFORMATION

CAMPUS SECURITY AND FIRE SAFETY

I. It shall be the responsibility of the department officers to implement this operating guideline.

St. John s University

Triangle Shirtwaist Company Fire (NEW YORK CITY, 1911) Evidentiary Packet

Fire Investigation Summary Fire Fighter Fatalities

Construction Site Fires

INCINERATOR / COMPACTOR FIRES

Family Foster Home Fire Safety Evaluation Checklist Instructions

Fire Investigation Terms

St. John s University

Learn About Fires Every day, Americans experience the horror of fire but most people don't understand it.

Spokane County Fire District 10 Station 10-1 ~ 929 S Garfield Road, Airway Heights WA Station 10-2 ~ 5408 W Lawton Road, Spokane WA 99224

Elko County Human Resources Employment Opportunity Announcement

Rancho Santa Fe Fire Protection District

MASTER COURSE OUTLINE

Required Materials For complete material(s) information, refer to

American Red Cross: Fire Safety Poll

Truck Company Operations

St. John s University

FRS 101 INTRODUCTION TO FIRE SERVICE 45 CLOCK HOURS 3 CREDIT HOURS. Course Title Lecture/Skill Total Fractional Credit

Date and Time of Incident. May 13, Breakout at 22:27 (approx) Noticed at 22:40 Notified by emergency call Extinguished at 17:30 on May 15th

HOME FIRES THAT BEGAN WITH UPHOLSTERED FURNITURE

F.R.A.M.E. EVENT NETWORKS used in "FRAME".

FIRE EMERGENCY POLICY

Patrick County Horizons Jeb Stuart Hwy. Stuart, Va

ANNUAL FIRE SAFETY REPORT October 1, 2018 ALBERT EINSTEIN COLLEGE OF MEDICINE JACK AND PEARL RESNICK CAMPUS BRONX, NY

St. John s University

Skill Sheet 17-I-1. Suppress an interior structure fire Direct, indirect, or combination attack. (NFPA 1001, , )

Fire Safety Checklist

Consumer Product Safety Commission Smoke Alarms Why, Where, and Which CPSC Document #559

RISK ASSESSMENT AND DISASTER MANAGEMENT PLAN 1.1 RISK ASSESSMENT AND DISASTER MANAGEMENT PLAN

IMPORTANCE of FIREGROUND VENTILATION PRACTICES and DYNAMICS IN FIREFIGHTING (PART I)

Preliminary Summary Report of Serious or Near Serious CAL FIRE Injuries, Illnesses and Accidents GREEN SHEET. Firefighter Burn Injury.

Fire Investigation Terms

EASTERN ARIZONA COLLEGE Fire Department Operations II

Fi Fire r safe saf t e y ty in yo in y ur home our home NCHLFT71

1.1.0 Protocols for the response to fires involving MRI Machines

U.S. Fire Administration Fire Safety Checklist. for Older Adults. FA-221/July 2012

St. John s University Fire Safety Plan

VOLUNTEER FIRE FIGHTER Certification Training Record

Transcription:

JUNE NEWSLETTER- FALLIING OBJECTS Struck by, or contact with a falling object is the third leading cause of firefighter deaths. According to the NFPA s annual death and injury survey only stress and being caught and trapped in a fire kill more firefighters. There are many falling objects that can kill and injure firefighters during a fire. Broken glass, slate shingles, coping stones, tools accidentally dropped, window air conditioners, smoldering mattresses, stuffed chairs, wood trim, cornices, TV antennas, flower boxes, loose bricks from parapets, chimneys and more can fall from buildings and kill or injure firefighters. These deadly airborne missiles are called "falling objects" and cause firefighter death and injury. However one of the most common falling objects around a burning building is broken glass from venting windows during search and rescue and smoldering rubbish discarded out windows during overhaul stage of a fire. Who is responsible when a firefighter inside a burning building performing search and rescue breaks a window of a smoke and heat filled room and the falling glass injures a firefighter operating on the ground around the perimeter of the burning building? Is it the firefighter who broke the window or the firefighter on the ground? www.vincentdunn.com

The perimeter of a burning building is one of the most dangerous areas on the fireground. The front sidewalk, side alley and rear yard are danger zones for falling objects. Firefighters must raise ladders, operate hose streams, vent windows and conduct forcible entry around the perimeter of a burning building and they are frequently injured by falling objects. During a fire we must be aware of falling object dangers from above. As soon as the assigned task is complete at the perimeter of the burning building, we should either enter the building or withdraw from the danger zone of falling objects. Several firefighters performing a primary search in a burning building can create a rainstorm of broken glass around the front, side or rear of a building. Firefighters working below can be cut by this falling glass. Glass in a residential building window is one sixteenth or one eighth of an inch thick and it is subdivided into small windowpanes. Glass in a commercial building is much more dangerous because it is thicker and heavier commercial building window glass can be one quarter or one half inch thick and weigh 2-1/2-pounds or 5 pounds per square foot. This means an 8 by 4-foot display window of l/2 inch thick glass when broken by a firefighter to vent smoke can create four, 40 pound, and razor sharp glass shards. A firefighter could be decapitated by one of these falling objects. So, firefighters operating around the perimeter of a building where glass windows are being vented should beware. Accountability The answer to the question posed at the beginning of this paragraph is, it is the firefighter outside the burning building is responsible when injured from falling glass. The firefighter inside, who broke the glass, is not responsible. This is because the firefighter inside is operating in a dangerous superheated, smoke filled fire environment searching for life. However, let's change the question and the stage of the fire operation. Who is responsible for an injury that occurs after the fire has been controlled, when during overhauling operations a smoldering object is thrown out of a window, or a glass is knocked out of a window frame and it strikes a firefighter below? Is it the firefighter www.vincentdunn.com 2

inside or the firefighter outside? The answer, now, is the firefighter inside. Why? It's because the firefighter operating inside the building is not working in a life-threatening environment. The fire is out, the rescue operations have ended, and his actions must be more controlled. Firefighters inside a burned out structure performing overhaul and salvage should never throw any smoldering object out a window or trim glass shards by knocking them outside, unless the area below has been cleared and a firefighter is standing guard, outside, at ground level. It is not sufficient to yell, "Watch out below" and then throws a smoldering chair or mattress out a window. Safe procedures The following are recommended safe operating procedure to take when a smoldering object must be thrown out of a window during overhauling or glass shards removed during salvage: 1. Obtain permission from the officer in command of the fire. 2. Notify, or assign, a firefighter outside the building to clear the area of civilians and act as a safety guard. 3. After the area is clear, the firefighter acting as guard signals when to throw the smoldering objects out or breaks off the jagged glass shards. 4. When all objects have been discarded out the window, notify the firefighter below assigned as a safety guard. Several years ago, at a fire I responded to, a company extinguished a small blaze in a stuffed chair. They removed a badly burned man who had fallen asleep in the chair with a cigarette and started the fire. Firefighters dragged the smoldering chair to a window, pushed it out on to a fire escape and threw it over the rail into a back yard. Unfortunately, a freighter assigned the outside vent position was in the rear yard about to climb the fire escape. He was struck with the smoldering char, knocked unconscious, suffered a disabling head injury and was forced to leave the fire service. Lessons Learned: 1. Do not throw objects from a window during overhaul unless the area isclear, and you have been signaled to do so by another freighter acting as a guide.(see above safe operating procedure). 2. When trimming broken glass from windows, knock the glass shard inside, not outside. www.vincentdunn.com 3

3. When assigned to operate around the perimeter of a burning building, be aware of the danger of falling objects and wear proper protective clothing. A well-fitted helmet, gloves and an eye-shield in the down position can protect you. 4. When venting windows from inside, attempt to open the window before breaking glass. Double paned windows in new and renovated buildings can be more quickly and fully opened manually then by breaking glass. 5. If a window is vented by breaking glass from the inside, to warn firefighters outside, first break a small section, and then take the entire window out. 6. A stuffed chair or mattress left inside a building after a fire has been extinguished can rekindle and kill people in a second fire after the firefighters leave the scene. It must be removed from the building. If it can not be thrown out a window, and if it must be dragging out a hallway, make sure it is completely extinguished. Fresh air in the hallway can cause the chair to burst into flame. So have a portable extinguisher or hose-line in the hall nearby ready to quench a flash fire. Completely extinguish the smoldering object once it is outside. Never take a smoldering piece of furniture down to the street an elevator. There have been several incident where building superintendent tried this and they were burned to a crisp inside the descending elevator with the flaming piece of furniture. 7. Realize commercial glass is more dangerous when broken then residential glass. The thickness and weight of falling glass pieces can cause serious lacerations and cut hose-lines. 8. The perimeter of a burning building is a dangerous place. After completing your assignment there, go inside the building or withdraw outside the collapse danger zone. www.vincentdunn.com 4

Firefighters questions: 1.In contact or falling objects account for what amount of firefighter deaths and Injury? A. It is the first leading cause of firefighter death and injury B. It is the second leading cause of death C. It is the third leading cause of death D. It is the fourth leading cause of deaths 2. The persons responsible for an injury caused by falling glass from window venting during the search and rescue phase of firefighting is? A. The firefighter inside venting the window B. The firefighter outside operating around the perimeter of the building C. The firefighter acting as a guide D. None of the above 3. The person responsible for an injury caused by smoldering mattress thrown from a window during overhauling is? A. the firefighter throwing the mattress out the window B. The firefighter outside operating around the perimeter of the building struck by the falling object. C. The company chauffeur D. None of the above www.vincentdunn.com 5

4. Which one of the following is not a common falling object danger during a fire? A. A window air conditioner that falls out of a window opened for venting B. A chimney top knocked over by a hose stream C. A tool slipping out of a firefighters hand while trimming a window during overhaul D. Cats jumping from windows escaping flames 5. Which one of the following is an incorrect answer regarding throwing smoldering material from windows during overhaul? A. Never do it B. Notify the officer in command for assistance of a safety guide such as a pump operator C. Only discard material out a window after the safety guide states all clear D. When finished discarding material out window notify the safety guide www.vincentdunn.com 6

JUNE NEWSLETTER- FALLIING OBJECTS ANSWERS Answers: 1-C; 2-B;3-A; 4-D;5-A www.vincentdunn.com 7