Radiant Heater Range SRP Superior Radiant Products From Powrmatic

Similar documents
Radiant Heaters Vacuum / Forced U-Tube & Linear Range

Powrmatic Control Systems Industrial & Commercial Heating Systems

Powrmatic PZN / PZN-X Hot Water Heat Emitter Industrial & Commercial Heating Systems

HEM Heat Exchange Modules

Destratification Fans Industrial & Commercial Heating Systems

NVxEA External Gas Unit Heater

Powrmatic PQ Electric Quartz Infrared Heaters - A Range

VPC Gas Cabinet Heater Range

PT Radiant Heater Range

TE Air Rotation Space Heater Industrial & Commercial Heating Systems

PT Radiant Heater Range Controlling your working environment. heating ventilation integrity

NVx Suspended Gas Unit Heater

CP+ Gas & Oil Cabinet Heater Range

PRODUCT BROCHURE. SHOP-FLOOR CMMs Designed With the Shop-floor in Mind

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

VPC Gas Cabinet Heater Range

OUH Suspended Oil Unit Heater Industrial & Commercial Heating Systems

TE Powrmaster Heater Range Controlling your working environment. heating ventilation integrity

NVS Condensing Gas Suspended Unit Heater

YOUR HOME. PVC-U WINDOWS DoorS CONSERVATORIES

The Powrmatic Vision Range

Powrmatic PZN / PZN X Hot Water Heater

CPx Gas & Oil Cabinet Heater Industrial & Commercial Heating Systems

OUH Oil Unit Heater Range Controlling your working environment. heating ventilation integrity

OUH Suspended Oil Unit Heater

PSO Gas & Oil Cabinet Heater Range

Powrmatic Air Conditioning Product Catalogue. Air Conditioning

Tallinna Lennujaam Communiaction Guidelines

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

OUH Suspended Oil Unit Heater Gas Oil Fired & Optional Kerosene

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

... Vision Radiant Tube Heating Systems ... ErP. ErP Lot 20 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

AMBIRAD.... Vision Radiant Tube Heating Systems...

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

CI/SfB X. Vision RADIANT TUBE HEATING SYSTEMS

Senior Living. Security and Access Solutions. ASSA ABLOY Hospitality

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

VSX models 15% more effective than standard radiant tube heaters,with payback of 6 months achievable when redeeming ECA allowances.

Title Brief description of project Retail

Education. Security and Access Solutions. ASSA ABLOY Hospitality

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS

A winning concept for circuit protection and connection technology. Circuit Protection you can trust

Workforce. Security and Access Solutions. ASSA ABLOY Hospitality

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

Dear Brokis partner,

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

Multi-family. Security and Access Solutions. ASSA ABLOY Hospitality

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

Sirius FS. Working towards a cleaner future

Installation Instructions

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

Návrh informačného a navigačného systém pre centrum mesta Bratislava, zóna Námestie SNP a Kamenné námestie a okolie

The Ideal Logic. Combination, Heat Only and System Boilers. Heating Solutions.

Setting A New Standard For Extra High Efficient, Infrared Tube Heaters 30% More Efficient Than Typical Models

INDEPENDENT COMBINATION & SYSTEM BOILERS.

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

We offer ceramic radiant heaters and infra-red radiant tubes.

Redring Powerstream Electric Flow Boilers. Efficient, safe and convenient electric space and water heating

CATALOG: HVAC - Gas Space Unit Heating

INSTALLATION AND OPERATION INSTRUCTIONS Double Linear OVERHEAD RADIANT TUBE HEATERS Models: PTDSL 15, PTDSL 25, PTDSL 30, PTDSL 35, PTDSL 40, PTDSL 45

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS

Sargasso Range. A new range of radiant panels for heating commercial applications

INFRARED RADIANT HEATERS

OPTIMA RADIANT TUBE HEATING SYSTEMS. Operation, maintenance and servicing manual

MODEL 466 Radiant / Convector Gas Fire Black Beauty

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

CPx Gas & Oil Cabinet Heater Range

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

PQ-A Electric Quartz Infrared Heaters

Why our flame is so natural... Our Technology & Engineering Excellence. Efficiency. Safety & Reliability. Fully Remote Controlled

RHC GAS FIRED HEATING COILS

Hotel. Security and Access Solutions. ASSA ABLOY Hospitality

Hotel. Security and Access Solutions. ASSA ABLOY Hospitality

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Sargasso Range. Installation manual. Sargasso A. Issue 001 January 2018 ENGLISH UK IRL SmithsEP.co.uk

Flue & Flue Kits for NVx, VPC & NVS

Sargasso Range. Installation manual. Sargasso S. Issue 001 January 2018 ENGLISH UK IRL SmithsEP.co.uk

VORTEX BLUE OIL RANGE

INSTALLATION AND OPERATING MANUAL. Vision VS Radiant

VORTEX BLUE OIL RANGE

Non-Contact Drying and Web Guiding

Recessed. Air Curtain. Fig 1. Recessed air curtain

IT-KN 7-7 kw. Dimensions. Heat load / Output (kw) 7.0. Angle of installation 15 / 30 / 45 / 60. Gas consumption. natural gas (m 3 /h) 0.

Domestic Gas Safety Assessments (DGA) Competency Assessment Certification Scheme for Registered Gas Installers

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

CORAYVAC Helps Reduce Energy Bills and Improve Comfort

Torch framed Installation Guide

ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR AMBIRAD VISION VS RANGE OF RADIANT TUBE HEATERS

Series RE Infrared Heater

Transcription:

Radiant Heater Range SRP Superior Radiant Products From Powrmatic www.powrmatic.co.uk +44 (0) 1460 53535 info@powrmatic.co.uk ErP READY 2018 POWRMATIC PRODUCT

INDUSTRIAL & & COMMERCIAL WARM RADIANT AIR HEATING HEATING SOLUTION SOLUTIONS Radiant Heaters Powrmatic CPx The range of Superior Radiant Products (SRP ) from Powrmatic feature optimal comfort and energy savings with two-stage technology. High/low capability allows for quicker recovery on the high fire and economical steady operation on the low fire with either U-Tube or Linear configuration. Lorem The range ipsum comprises dolor sit amet, with outputs consectetur ranging adipiscing from 10 elit, to sed 60kW do offering eiusmod maximum tempor incididunt efficiency ut from labore lightweight et dolore radiant magna aliqua. heating Ut tubes enim ad providing minim veniam, direct heat quis and nostrud warmth exercitation in a multitude ullamco of laboris industrial, nisi commercial ut aliquip ex and ea commodo retail applications. consequat. Duis The aute range irure of dolor radiant in heaters reprehenderit are the in perfect voluptate solution velit esse designated cillum dolore spot heating. eu fugiat Whether nulla pariatur. you need Excepteur to heat employees sint occaecat in your factory cupidatat whilst non they proident, work or sunt heat in culpa areas qui of crops officia or deserunt flowers within mollit anim your horticultural id est laborumapplications, radiant heating provides a flexible heating solution. Superior Radiant Products (SRP ) is an industry leader in the design and manufacture of energy GAS G20 - GROUP H / G25 GROUP L efficient infrared heating solutions and is dedicated to providing superior technology and superior performance. OIL GAS LPG LPG 35 SEC FUEL (STANDARD) 28 SEC FUEL (OPTIONAL) NATURAL GAS (G20) PROPANE G31 PROPANE (G31) s Available PL - Powrmatic Linear PU - Powrmatic U-Tube PVL - Powrmatic Vaccum Linear PVU - Powrmatic Vaccum U-Tube PVDL -Powrmatic Vaccum Double Linear ErP READY 2018 POWRMATIC PRODUCT Efficiency and ErP Compliance From 1st January 2018 all radiant heaters used to provide comfort for the occupants of a heated space are required to meet minimum standards of seasonal efficiency as determined by the Ecodesign regulation (EU) 2015/1188, Directive 2009/125/EC - Lot 20. Compliance to the standard is mandatory. Radiant heaters placed on the market after 1st January 2018 comply with the requirements of the standard. Installer Benefits Lorem ipsum dolor sit ame 40,000 to 220,000 BTU/h High/Low as standard Natural Gas or LPG configurations of U and L, horizontal or 45 Self-diagnostic ignition module Hinged service cover easy to service Peace Of Mind Two year parts and one year labour guarantee Full technical support In Partnership With SRP Superior Radiant Products (SRP ) is an industry leader in the design and manufacture of energy efficient infrared heating solutions and is dedicated to providing superior technology and superior performance. SRP offers a complete range of gas fired low and high-intensity infrared heaters for industrial, commercial, agricultural and residential applications. 2

TYPICAL APPLICATIONS TYPICAL APPLICATIONS Warehouses Factories Factories Garage Workshops Distribution Garage Workshops / Logisitc Centres Aircraft Distribution Hangars Centres Horticultural Aircraft Hangers & Garden Centres Efficient Reflectors Made with bright ASTM 1100 Aluminium, the aluminium reflectors are made with a 100% efficient reflector profile and tested and proven superior material - designed to maximise downward radiant heating effect and increase efficiency. The reflector extends below radiant tube ensuring all radiant energy is directed downwards. t Heat Treated Tube Design Made with a heat treated aluminised calorised emitter tube surface - for flake free and cleaner working environment and little maintenance. The 0.85 emissivity provides maximum radiant output and improves emission levels. Burners & Housing The burner housing is made with galvanised steel, welded then painted for maximum corrosion and moisture resistance. The components are placed in a separate compartment for protection and ease of maintenance whilst running and does not require any mounting support. Spot Heating With radiant heating systems, different zones within the same room can have different temperatures. This means energy can be saved and comfort increased. Powrmatic radiant heaters provide efficient and economical protection against cold draughts. The radiated heat naturally migrates to where it is most needed, which means that cold surfaces such as windows will attract the radiant heating. Induced Vacuum & Forced Burners The range can be supplied with either a induced vacuum burner or a forced blown burner onto the firing tube depending on your requirements and installation. 2 Stage Cycle Technology The series range offers dual output (two stage) burners, which automatically operate in high-fire and low fire modes for quicker heat recovery, enhanced fuel savings, and greater comfort. Brackets & Suspension Supported by heavy-duty chrome plated hangars and suspended from the ceiling with chain. These rugged hangers are designed to carry the weight of the entire system and can be turned to point reflectors on a 45 degree angle if needed. Controls By using the Powrmatic MC200, controlling the heating in zones you can achieve different temperatures in different areas of the same building. This is very useful in situations where some areas are used for production and others for storage. Approvals Radiant heaters are type tested and CE approved. In addition heaters placed on the market subsequent to 1st January 2018 meet the seasonal efficiency requirements of ErP Lot 20. CUSTOMER BENEFITS CUSTOMER BENEFITS Energy efficient Cost effective spot heating Range of sizes and configurations Lcon sectetur adipiscing elit, sed do eiusmod tempor incididunt Space ut saving labore off-floor et dolore horizontal magna option aliqua. Duis aute irure dolor in reprehenderit in voluptate Colour velit (RAL) esse options cillum Lorem ipsum dolor sit Manufactured amet, consectetur in the United adipiscing Kingdom elit, Lcon sectetur adipiscing elit, sed do eiusmod tempor 3 incididunt ut labore et dolore magna aliqua. APPROVED PRODUCT

Technical Specification PL & PU PL & PU (Powmatic Linear & U-Tube) Heat Input (Natural Gas) Heat Input (Propane LPG) PL (Linear) PU (U-Tube) 10 20 30 40 50 60 20 30 40 High Fire kw (gross) 11 22 30 43.5 52.5 6.1 22 30 43.3 Low Fire kw (gross) 8.5 17 23 32 40 44.5 17 23 32 High Fire kw (gross) 10.5 21.5 29.5 40 N/A 21.5 29.5 40 Low Fire kw (gross) 8.5 16.5 23 31 N/A 16.5 23 31 Weight Kg 46 62 64 80 112 127 64 66 82 Gas Connection BSP/Rc ½ ½ Supply Pressure mbar Nat Gas - 20 / Propane - 37 Nat Gas - 20 / Propane -37 Electrics V/ph/Hz 230/1/50 230/1/50 Maximum Gas Flow Rate m 3 /h Nat Gas 1.05 2.10 2.86 4.15 5.00 5.81 2.10 2.85 4.15 m 3 /h LPG 0.41 0.83 1.13 1.64 N/A 0.83 1.13 1.64 Flue Diameter mm 100 100 Air Inlet Connection mm 100 100 Notes Fuel Consumption and output figures based upon nett calorific values as follows: - Natural Gas (G20) nett CV 34.02 MJ/m 3 - LPG Propane (G31) nett CV 88.00 MJ/m 3 Powrmatic radiant heaters have efficiency levels which comply with the requirements of United Kingdom Part L Building Regulations and the seasonal efficiency requirements of the Ecodesign regulation (EU) 2015/1188, Directive 2009/125/EC Lot 20 (Known as ErP and mandatory as from 1st January 2018) Dimensions PL & PU (Powmatic Linear & U-Tube) PL (Linear) PU (U-Tube) 10 20 30 40 50 60 20 30 40 A mm 3400 9500 9500 12550 18650 21700 5400 5400 5400 B mm 400 400 400 400 400 400 900 900 900 C mm 400 400 400 400 400 400 390 390 390 4

Technical Specification PVL & PVU PVL & PVU (Powmatic Vacuum Linear & Vacuum U-Tube) Heat Input (Natural Gas) Heat Input (Propane LPG) PVL (Vacuum Linear) PVU (Vacuum U-Tube) 20 30 40 50 20 30 40 High Fire kw (gross) 22 30.5 41 53 22 30.5 41 Low Fire kw (gross) 17.5 24.5 32.5 41 17.5 24.5 32.5 High Fire kw (gross) 22 30 38 N/A 22 30 8 Low Fire kw (gross) 17 23.5 29.5 N/A 17 23.5 29.5 Weight Kg 62 64 80 112 64 66 82 Gas Connection BSP/Rc ½ ½ Supply Pressure mbar Nat Gas - 20 / Propane - 37 Nat Gas - 20 / Propane - 37 Electrics V/ph/Hz 230/1/50 230/1/50 Maximum Gas Flow Rate m 3 /h Nat Gas 2.10 2.91 3.91 5.05 2.10 2.91 3.91 m 3 /h LPG 0.83 1.15 1.54 N/A 0.83 1.15 1.54 Flue Diameter mm 100 100 Air Inlet Connection mm 100 100 For PVDL (Powrmatic Vacuum Double Linear) Units the heat input, weight, and maxmimum gas flow rate are doubled) Notes Fuel Consumption and output figures based upon nett calorific values as follows: - Natural Gas (G20) nett CV 34.02 MJ/m 3 - LPG Propane (G31) nett CV 88.00 MJ/m 3 Powrmatic radiant heaters have efficiency levels which comply with the requirements of United Kingdom Part L Building Regulations and the seasonal efficiency requirements of the Ecodesign regulation (EU) 2015/1188, Directive 2009/125/EC Lot 20 (Known as ErP and mandatory as from 1st January 2018) Dimensions (Powmatic Vacuum Linear & Vacuum U-Tube) PVL (Linear) PVU (U-Tube) 10 20 30 40 50 60 20 30 40 A mm 3400 9500 9500 12550 18650 21700 5400 5400 6950 B mm 400 400 400 400 400 400 900 900 900 C mm 400 400 400 400 400 400 250 250 250 For PVDL (Powrmatic Vacuum Double Linear) Units dimension A is doubled 5

Clearance To Combustibles PL & PU (Powmatic Linear & U-Tube) Below Side Above Reflector End Front Rear (mm) PL 10, 20, 30, 40 1180 910 100 500 1630 100 PU 20, 30, 40 1930 940 100 500 1630 100 PL 50, 60 2030 1120 150 500 1830 100 Notes: The stated clearance to combustibles represents a surface temperature of 50 C above room temperature It is the installer s responsibility to ensure that adjacent materials are protected from deterioration. PVL, PVU, PVDL (Powmatic Vacuum Linear, Vacuum U-Tube & Vacuum Double Linear ) Below Side Above Reflector End Front Rear (mm) PVL / PVDL 10, 20, 30, 40 1180 910 100 500 1630 100 PVU 20, 30, 40 1930 940 100 500 1630 100 PVL / PVDL 50, 60 2030 1120 150 500 1830 100 6

Your Installer Guide General The following notes are provided as a guide, however installers and operators should fully acquaint themselves with the more detailed guidance provided in the relevant installation manual. For copies of such manuals please consult our technical department or visit our website - www.powrmatic.co.uk Standards All Powrmatic radiant tube heaters are specifically designed for environmental space heating applications only and must be installed, commissioned and operated with due regard to appropriate regulations including, but not limited to, the Gas Safety (Installations and Use) Regulations 1998 for gas fired products, the Health and Safety at Works Act 1974, relevant Codes of Practice, BS-13410:2001 and other relevant standards, the possible requirements of Local Authorities, Fire Officers and insurers as well as Powrmatic s installation manual. Combustion Air, General Ventilation & Fluing Within the United Kingdom mandatory regulations apply concerning the provision of combustion air and general heater ventilation. Powrmatic radiant tube heaters may be installed in either vented (flued) or unvented (unflued) mode however specific regulations and requirements apply for the safe evacuation of flue gases. Installers must refer to the Installation, Operation and Maintenance manual prior to commencing works. Installation Clearances Particular clearances are necessary for the correct and safe function of the heater as well as for maintenance purposes. Such clearances are confirmed in the relevant installation manual. Position,Location & Assembly Powrmatic radiant heaters are designed for internal location only. Effective heating is dependent upon mounting height as well as location within the building or heated zone. Minimum, as well as maximum, mounting heights must be observed. Suspension materials must be non-combustible and of sufficient strength and integrity to support the weight loading. Heaters must be supported from permanent structures and on no account be supported from gas lines or other pipework. Heaters should be supported along the entire length using the appropriate mounting points provided. Linear heaters should have a 0.25 slope upwards towards the burner. Consideration should also be given to flue routes and points of exit, gas, electrical and control connections, the radiant heating characteristics of the heater, issues of public access and the siting of environmental control stations and/or remote temperature sensors where the position needs to be representative of the zone temperature to which they refer. Heaters should not be installed in hazardous areas or areas where there is a foreseeable risk of flammable or corrosion inducing particles, gases or vapours being drawn into the combustion air circuit. Effective and safe operation heaters is entirely dependent upon correct on-site assembly of the constituent parts. The assembly instructions provided must be strictly followed. Pipework Care should be taken when sizing gas pipework to ensure that minimum gas inlet pressures are not compromised under dynamic load conditions. Isolating valves and service unions should be provided for each heater and pipework installed with due regard for relevant standards and Codes of Practice. The final connection to the heater must include a suitable flexible gas pipe so that the fixed element of gas pipework cannot be influenced or effected by expansion and movement of tube heater. Guarantee Powrmatic radiant tube heaters are provided with a comprehensive guarantee. For United Kingdom sales the heater has the benefit of a two year parts and one year labour guarantee. All guarantees are subject to terms and conditions. 2 YEAR 1 YEAR PARTS WARRANTY LABOUR WARRANTY In all cases installers must refer to the Installation, Operation and Maintenance manual prior to commencing works. 7

Powrmatic are a leading British manufacturer of industrial and commercial heating equipment. With over 60 years of experience in the HVAC industry, our products are built with integrity, and characterised by high quality and energy-saving designs, delivering exceptional performance and facilitating compliance with energy and emission regulations. Powrmatic are also a specialist British manufacturer of natural, powered and smoke ventilation products working closely with a wide range of architects and consultants whilst also a supplier of a range of air conditioning and evaporative cooling equipment. We provide a full product application advice service for architects, mechanical engineers, installers and end users to ensure the best products are selected to meet the required budget, design and regulatory requirements. Our heating and ventilation engineers are also supported by distribution partners and a network of installers who are knowledgeable in the supply, installation and maintenance of all of our equipment. Get in touch United Kingdom Office Powrmatic Limited Hort Bridge Ilminster Somerset TA19 9PS tel: +44 (0) 1460 53535 fax: +44 (0) 1460 52341 e-mail: info@powrmatic.co.uk web: www.powrmatic.co.uk Ireland Office Powrmatic Ireland 45 Broomhill Close Tallaght Dublin 24 tel: +353 (0) 1452 1533 fax: +353 (0) 1452 1764 e-mail: info@powrmatic.ie web: www.powrmatic.ie FOR THE LATEST NEWS, CASE STUDIES, AND TECHNICAL SUPPORT FOLLOW US ON #keepingthenationwarm ICOM Energy Association EURO-AIR QUALITY Powrmatic pursues a policy of continues improvement in both design and performance of its products and therefore reserves the right to change, amend or vary specifications without notice. Whilst the details contained herein are believed to be correct they do not form the basis of any contract and interested parties should contact the Company to confirm whether any material alterations have been made since publication of this brochure. Issue 5.6 ErP January 2018