HOME OWNERS GUIDE ERV MODEL PE 7.15 PE SS Product of Imperial Air Technologies

Similar documents
Heat or Energy Recovery Ventilation System

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

Limited Lifetime core warranty. 5-year warranty on balance of unit.

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

Heat Recovery Ventilators models:

READ AND SAVE THESE INSTRUCTIONS

Maintenance Matters. Maintaining Your Heat Recovery Ventilation System

VENTILATORS VH30100 COMPACT HEAT RECOVERY VENTILATOR VE30100 COMPACT ENERGY RECOVERY VENTILATOR. Installation and Operation Manual.

BRONZE MODELS 90H* 190H READ AND SAVE THESE INSTRUCTIONS

VIGÖR HRV PLUS AND VIGÖR ERV

HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V

HEAT RECOVERY VENTILATORS MODELS AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, NOVOFIT 1.0 AND ENERGY RECOVERY VENTILATOR MODEL AVS ERV EKO 1.

USER GUIDE HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V AND 60H NOVO+, MODEL ERV 90H-V ECM PLEASE READ AND SAVE THESE INSTRUCTIONS

USER GUIDE MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY rev.

Indoor Air Quality Product Brochure.

Address of your installer

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

HEAT RECOVERY VENTILATORS AND ENERGY RECOVERY VENTILATORS CONSTRUCTO 1.0 MODELS: Model no.: (HRV with ports on top)

Indoor Air Quality Product Brochure.

Heat Recovery Ventilation Systems OWNER S GUIDE

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

Light commercial models

HEAT RECOVERY VENTILATORS MODELS AVS E15 ECM HRV, AVS E15 HRV, AVS E10 HRV AND ENERGY RECOVERY VENTILATOR MODEL AVS E15 ECM ERV

SH, VH & SE Series. Installation, Operation and Maintenance Manual. Heat & Energy Recovery Ventilators SH 704 VH 704 SE 704

READ CAREFULLY AND SAVE R3

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

Installation Information

SER Series. fantech. Installation Manual. Energy Recovery Ventilators. ser 1504 ser 1504n ser 2004 ser 2004n ser 3204d ser 3204n

For Models Superventor Series

Put the V back in HVAC

Ventilation Solutions IAQ Canada

INSTALLATION INSTRUCTION & OWNER S GUIDE

SLIDER CASEMENT AIR CONDITIONER

IAQ VENTILATION SOLUTIONS

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

Ventilation Solutions IAQ Canada

Tech to Tech May 07 HRV s & ERV s

USER MANUAL HRV150S* HRV190S* AND ERV180S READ AND SAVE THESE INSTRUCTIONS

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

IAQ VENTILATION SOLUTIONS

SAFETY AND INSTALLATION MANUAL MODEL 8100

WINDOW/WALL-TYPE ROOM AIR CONDITIONER

USER S INFORMATION MANUAL (2,4)SG13B

AIR CONDITIONER ELECTRONIC CONTROL

Address of your installer

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

Packaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner.

MODEL 598A TWO-SPEED PLUS CENTRAL AIR CONDITIONER

SER150. Installation Manual. Energy Recovery Ventilators

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

ROTARY CONTROL AIR CONDITIONER

OWNER S MANUAL. Portable Air Conditioner. Product defect? Not working properly? DO NOT return this product to the store where you purchased it.

AC Portable Air Conditioner AC-14100E, AC-14100H OWNERS MANUAL. Read and save these instructions.

Residential Heat & Energy Recovery

Heat Recovery Energy Recovery Total Recovery Ventilators. Balanced Ventilation for Residential and Commercial Buildings. Advancing Ventilation

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

User s Information Manual

Instruction Manual Item No.: V~, 60Hz

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

WHHR Midi & Midi Lite

KHP Models. KHP Series. Heat Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

50% 80% 7 Years. Filter. Ventilation Solutions IAQ Canada. Ventilate. of our time is spend indoors. Limited warranty on motors

NU800, NU1200 & NU1600

Instruction Manual Item No.: V~, 60Hz

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

NO VENTING REQUIRED 120V AC;

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

Table of contents. Installing the charcoal filter 18 Cleaning the prefilter 18 Long term storage 18 Troubleshooting 19 Limited warranty 22

SER Series. Installation Manual. Energy Recovery Ventilators SER 1504 SER 2004 SER 3204D

OPERATIONS & MAINTENANCE MANUAL RESIDENTIAL HEAT & ENERGY RECOVERY VENTILATORS TO BE COMPLETED BY CONTRACTOR AFTER INSTALLATION

HEAT RECOVERY VENTILATORS HRV 60H ERV 60H. User Guide AND ENERGY RECOVERY VENTILATORS. Model no.: (HRV with ports on top)

SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL

5) Do not start or stop the unit by inserting or pulling out the power plug.

OWNER S MANUAL ELECTRIC FIREPLACE INSERT. Model No.: WESTERN (EF42D-45D) WARNING CAUTION

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL HEAT & ENERGY RECOVERY VENTILATORS FOR MODELS: H/E80 H/E130

TR Series - The Ultimate ERV

Bosch 80% AFUE Gas Furnace BGS80 Model

user s information manual

INSTALLATION AND OPERATION INSTRUCTIONS

Desiccant Dehumidifier

Residential Duct Mount Builder s Box Media Air Cleaner

Bench Series Ovens Models 21 / 31 / 51 Operating Manual

Installation Instructions

INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

INDOOR AIR QUALITY KITS AND ACCESSORIES /2014. Supersedes 06/2014

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

user s information manual

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Alice. In Wall Recessed Electric Fireplace Model Number: (EF172B, EF173B, EF174B, EF175B, EF176B) OWNER S MANUAL

INSTALLATION GUIDE VB0180 VB0148

HYBRID DRYER. PDH1 - PDH2 Series. Save These Instructions

UNDER CABINET RANGE HOOD. This manual is made with 100 % recycled paper.

Transcription:

HOME OWNERS GUIDE RESIDENTIAL USE ONLY HRV MODEL PH 7.15, RNC1.5 PH 10.22, RNC2.0, RNC2.0ES XDH 7.15 HRV C3.14, RNC1.0, RNC12 SS 3.80 SOLACE, XPH1.5, XPH2.0 ERV MODEL PE 7.15 PE 10.22 SS 3.80 Product of Imperial Air Technologies Imperial Air Technologies Inc. reserves the rights to modify a product, without prior notice, whether in price, design, color or codes, in order to offer at all times quality products that are highly competitive. Imperial Air Technologies 480 Ferdinand Blvd., Dieppe, NB E1A 6V9 1-888-724-5211 Fax 506 388-4633 www.imperialgroup.ca

Page 2

IMPORTANT - PLEASE READ MANUAL BEFORE INSTALLATION CAUTION: Do not install in a cooking area or connect directly to any appliance. Turn off all integral disconnects before servicing. NOTICE: Prior to installing, serious consideration must be taken to insure this ventilation system will operate properly if integrated to any other type of mechanical system, i.e. a forced air system, or an air handling unit. To insure proper operation & compatibilities of both system, it is required that the airflow s of the Heat Recovery Ventilator (HRV) or Energy Recovery Ventilator (ERV) be balanced, by following the procedures found in this manual. The way that your Heat/Energy-recovery ventilator is installed may make a significant difference to the electrical energy that you will use. To minimize the electricity use of the Heat/Energy-recovery ventilator, a stand-alone fully ducted installation is recommended. If you choose a simplified installation that operates your furnace airhandler for room-to-room ventilation, an electrically efficient furnace that has an electronically commutated (EC) variable speed blower motor will minimize your electrical energy consumption and operating cost. LIMITATIONS: The product is for residential applications only. Must be installed in accordance with all national and local regulations, building and safety codes. TO REDUCE OR AVOID THE HAZARDS OF ELECTRIC SHOCK AND FIRE: CAUTIONS CONCERNING THE OPERATION AND FULL EFFICIENCY OF THIS PRODUCT: Before servicing or cleaning the HRV system, always remove the power cord from the AC wall outlet. To reduce the hazards of electric shock or fire, do not perform any service to the HRV system other than those stated in the operating manual instructions. To reduce the risk of electric shock, this ventilation system (HRV/ERV) comes equipped with a 3-prong plug-in. This plug will fit in a polarized outlet only one way. Do not use ventilation system for outdoor application. Do not pull or twist power cord when disconnecting it from the ventilation system. Grasp the plug firmly, not the cord. Do not modify the power plug in any way; if modified, risk of electric shock fire or even damage to the unit may occur. Do not use the ventilation system for removal of flammable fumes, gases or connect directly to any appliances. Use a dedicated AC 120V outlet only. Do not obstruct or cover the air intake or air outlet of the ventilation system. Do not modify, repair or disassemble this system. These tasks are to be performed by authorized serviced personnel only. Fire, electrical shock and/or bodily injury may occur if these warnings are not followed. To prevent injuries, do not operate the ventilation system, while servicing or maintaining. There are impeller wheels turning at a very high speed that must fully stop rotating prior to accessing the inside of the unit. Always assess the operation of the ventilation system on how it may interact with vented combustion equipment (ie. Gas Furnace, Oil Furnace, Combustion, Appliances, etc.) Do not use for swimming pool/spa applications. ABOUT US Imperial Air Technologies Inc. is the only manufacturer that offers you a complete range of products designed to improve indoor air quality, and that provides a wide selection of accessories to facilitate installation. Our vision To offer a complete range of products that satisfies environmental concerns. Whether your needs involve ventilation or filtration, we have the customized solution for you, with its range of quality products backed by the best warranty in the industry. SECTION PAGE 1. Operations & Main Fonctions....................... 4 2. Types of Installations............................4 3. Description of your Ventilation System................. 5 4. Operation of the Duotrol TM System....................6 5. Operation of your Wall Controls.................... 7-12 6. Troubleshooting...............................13 7. Maintenance.................................13 8. Warranty...................................15 CONTENTS Page 3

1. OPERATION & MAIN FUNCTIONS Your ventilation system has been engineered & designed to improve your indoor air quality by reducing during the winter time, excess humidity or other contaminants in your home and replacing this air by fresh filtered air from the outdoors. During colder seasons, the units heat recovery core (polypropylene core) will reclaim the heat from the outgoing stale air and use this heat to temper the incoming fresh air, which reduces the cost of effectively ventilating your home during winter. NOTE: Reverse process occurs in the summer months. 2. TYPES OF INSTALLATIONS Fresh air Exhaust air Best Independent system Bathroom Control HRV/ERV Exhaust air hood Fresh air supply hood Better Exhaust at the source and supply in the return Bathroom Control Forced air system HRV/ERV Exhaust air hood Fresh air supply hood Good Exhaust and supply in the return Bathroom Control Forced air system HRV/ERV Exhaust air hood Fresh air supply hood Page 4

3. DESCRIPTION VENTILATION SYSTEM Fresh Air from Outside Port A : Inlet for fresh outdoor air. Side View Exhaust Air to Outside Port B : Outlet for exhausting stale, humid & contaminated air to the outdoors after transferring its heat to the recovery core. PH, PE, Solace, XPH1.5, XPH2.0, RNC1.5, RNC2.0 & RNC2.0ES Fresh Air From Outside Exhaust Air From Home A Exhaust Air From Home Port C : Exhausts stale, humid & contaminated air to the outside from multiple location of the home or from the return air of the forced air system, prior to passing threw the heat recovery core. Ex: Bathroom, laundry room etc. C Exhaust Air To Outside Fresh Air to Home Port D : Introduces & distributes clean & fresh air to your home. The homes fresh air ports are normally installed in the main living areas or in the return/supply duct of the forced air system. Ex: Living room, bedrooms, recreation rooms etc. Fresh Air To Home B D VENTILATION SYSTEM WITH RECIRCULATION MODE MODEL XDH Advanced Side View Defrost Sequence / Recirculating Mode Air frais provenant E de l extérieur Air vicié évacué à l extérieur Évacuation de l air vicié vers l extérieur Fresh Air From Outside B Exhaust Air To Outside A Recirculated warm Airambient frais distribué air to home vers l intérieur Exhaust Air Recirculated From Home warm ambientc Fresh Air air to home To Home D D Continuous Ventilation Mode Continuous Ventilation Mode Fresh air from outside Exhaust air from home Fresh air from outside Exhaust air from home C A Exhaust air to outside Exhaust air to outside Fresh air to home Air frais provenant de l extérieur B Air vicié évacué à l extérieur A B Évacuation de l air vicié vers l extérieur Fresh air C to home D Front View Top View B Air frais provenant de l extérieur B Air vicié évacué à l extérieur A C Évacuation de l air vicié vers l extérieur Air frais distribué vers l intérieur D Heat Recovery Core: A polypropylene cross-flow type it is designed to transfer the heat between both exhaust & supply air streams without allowing any contamination or mixing of both air streams to maximize the efficiency and improves your indoor air quality. *Ideal for cold climates. Energy Recovery Core: An energy recovery core transfers latent energy (humidity) & heat from one airstream to the other without mixing the airstreams for maximum efficiency and improves your indoor air quality. *Ideal for warm humid climates. Condensate Drain Pan & Drainage Hose: Captures the water that accumulates during the heat transfer and defrosts sequence in the fall, winter & early spring seasons. Drain hose is connected to the drain pan and serves as drainage for the accumulation of water. It is normal during summer months to find no condensation in drain pan or in drainage hose. Automatic Defrost Sequence: The defrost sequence is electronically controlled to measure the incoming outdoor air temperature, the sequence is activated at -5 C (23 F) and colder. This system eliminates that the heat recovery or energy recovery core doesn t build with ice or freezes. XDH Model defrost sequence: An automatic motorized damper closes the fresh air port, the exhaust fan shuts down, the supply fan increases speed pending the measured outside temperature and will draw air from the 5th port located upper left side. Exhaust Air From Home C Fresh Air To Home D A Air frais distribué vers l intérieur D Synthetic Filters: Capture the largest particle & protects your heat recovery core from potential obstruction by these particles. PH, PE, Solace XPH1.5, XPH2.0, SS 3.80, RNC1.5, RNC2.0 & RNC2.0ES Series defrost sequence: Supply fans shuts down, the exhaust fan speed increases pending the measured outside temperature. COMPACT VENTILATION SYSTEM Fresh Air From Outside B Exhaust Air To Outside A DuotrolTM Systems: Selects your ventilation modes (OFF, CONT or INTER), also to adjust your continuous airflow rates: Increasing (+)/Decreasing (-). German Engineered Motors(2): Designed with high performance and reliability, they are maintenance free for your comfort and peace of mind. Recirculation of warm Advanced Defrost Sequence / Recirculating Mode ambient air without unpleasant odors Recirculation of warm ambient air without unpleasant odors 5th Port on XDH Models only E : Re-circulating port during defrost sequence, or with specific wall control Vectra EHC1.5, (RD-3D & RD-4D) Re-circulation mode can be chosen. (Ref. The Installation Guide) D C3.14HRV, RNC1.0 & RNC12 Defrost sequence: An automatic motorized damper closes the supply & exhaust air and opens the re-circulation damper. this allows the unit to re-circulate the ambiant air in the house. The supply motor is then off. C Page 5

4. OPERATING OF THE DUOTROL SYSTEM Our Duotrol TM System is state of the art technology simplified for quick and easy operation. The Duotrol System serves two purposes: 1. ACTS AS A MODE SELECTOR IN RUN MODE (OFF, CONT & INTER) OFF: When the selector switch is in the OFF position the ventilation system will not come on even if there s a request for ventilation from any remote controllers. CONT: When the selector switch is in the CONT position the ventilation system will exhaust stale indoor air to the outside and will introduce fresh outdoor air continuously on low speed except when there is a request for ventilation by one of the remote controllers then the ventilation system will exchange at high speed. (Recommended for maximum indoor air quality.) INTER: When the selector switch is in the INTER position the ventilation system will only run on high speed when there is a request for ventilation. At this time the unit will run on high speed until the level of humidity is below the set point. The T-3 timer has completed its time period or once the cycles per hour has completed its cycle. TIP: During hot and humid days, it is recommended that you put the system on INTERM mode. This will reduce the amount of warm and humid fresh air coming inside the house. NOTE: The following controls (EHC1.0, EHC1.5, RD-2, RD-3P, RD-3D, RD- 4P & RD-4D) will override any setting on the Duotrol TM all except when in the OFF position. 2. ACTS AS VARIABLE SPEED SELECTOR When the (+) button is pushed this will increase the CONT speed of both ventilation system motors from the previous settings. When the (-) button is pushed this will decrease the CONT speed of both ventilation system motors from the previous settings. NOTE: When the LED stops blinking the unit is at its maximum high speed or at its maximum low speed. IMPORTANT: If speed setting is too high, extreme dryness can occur in home during winter months. If speed setting is too high, extreme humidity levels can occur during hot humid days. IMPORTANT: If speed setting is too low, above normal humidity, stale and contaminated air levels can occur in home. Page 6

5. OPERATING YOUR WALL CONTROLS VECTRA EHC1.0 BASIC VENTILATION WALL CONTROL Entry level touch panel control Compatible with all HRV's and ERV's Friendly Energy Savings Mode Simple user interface (No Programming) LED provides instant system feedback Lexan Graphic Touch Pad 7 Operating modes ON/OFF BUTTON: Powers ON/OFF the HRV or ERV. NOTE: When powered OFF, this puts the unit in stand-by mode, it will respond to auxiliary controls. (If present) PREF BUTTON: Mode selection : ECONO / VENT / 20MIN/HR ECONO Friendly continuous ventilation energy savings mode.the ventilation system operates at reduced rate of 30% in continuous and at a reduced rate of 15% during maximum ventilation speed. VENT Provides continuous ventilation speed set by the installer. NOTE: The ventilation system will increase to high speed when a auxiliary control has been activated, if installed. (Recommended for best indoor air quality.) 20 MIN/HR Consist of 20 minutes cycle at maximum ventilation speed then followed by 40 minutes intermittent (the ventilation system is in stand-by mode) NOTE: The ventilation system will increase to high speed when a auxiliary control has been activated during the 40 minute cycle, if installed. VECTRA EHC1.5 PROGRAMMABLE DIGITAL WALL CONTROL Econo Friendly Energy Savings Mode Programmable digital contro High contrast LCD Display backlight Compatible with all HRV's and ERV's Interface provides instant system feedback 12 Operating modes VENT Provides continuous ventilation speed set by the installer. NOTE: The ventilation system will increase to high speed when a auxiliary control has been activated, if installed. (Recommended for best indoor air quality.) ECO Friendly continuous ventilation energy savings mode.the ventilation system operates at reduced rate of 30% in continuous and at a reduced rate of 15% during maximum ventilation speed. RECIRC* Recirculation ventilation mode. The recirculation mode recycles already-heated ambient air from the home and re-distributes throughout your home. 20MIN/HR Consist of 20 minutes cycle at maximum ventilation speed then followed by 40 minutes intermittent (the ventilation system is in stand-by mode) or a continuous ventilation speed depending the selected mode each hour. NOTE: The ventilation system will increase to high speed when a auxiliary control has been activated during the 40 minute intermittent mode cycle, if installed. 20MIN/RECIRC* RECIRC:Consist of 20 minutes cycle at maximum ventilation speed then followed by 40 minutes recirculation of warm ambiant air (the ventilation system is in recirculation mode) or a continuous ventilation speed depending the selected mode each hour. NOTE: The ventilation system will increase to high speed when a auxiliary control has been activated during the 40 minute recirculation mode cycle, if installed. DEHUM Humidistat override mode and automatically ventilates at maximum speed based in indoor relative humidity settings. MAX Maximum continuous ventilation speed MED Medium continuous ventilation speed MIN Minimum continuous ventilation speed ON/OFF The ventilation system is powered ON/OFF. NOTE: Puts the ventilation system in stand-by mode, it will respond to auxiliary controls. (If present) SUMMER/ÉTÉ Dehumidistat Override = OFF * Compatible with XDH7.15, C3.14, RNC1.0 & RNC12 only. Page 7

5. OPERATING YOUR WALL CONTROLS (CONTINUED) Adjusting your RD Series Humidity Sensor Dial should be set accordingly or relative to the outside conditions. During winter season the Humidity Sensor Dial should be set within the comfort zone range (60% COMFORT ZONE 30%). If the home has excess dryness, adjust the Humidity Sensor Dial towards the higher settings. (Turn counter clockwise). If excess humidity is encounter turn the Humidity Sensor Dial to a lower setting. (Turn clockwise). Determining the humidity level in your home (turn the round humidity sensor dial counter clockwise to the OFF position, then turn it back clockwise slowly until you hear click. The click is the approximate level of relative humidity. NOTE: The comfort zone for relative humidity is between 60% and 30%; please adjust accordingly to your needs or requirements. RD-1 MODEL TM DEHUMIDISTAT Dehumidistat to select the humidity level RD-2 MODEL TM DEHUMIDISTAT Dehumidistat to select the humidity level Range Control (OFF, NORMAL and REDUCED) Green LED light on = OVERRIDE Orange LED light on = CONT/INTERM Comes complete with Relative Humidity Sensor Dial. RELATIVE HUMIDITY SENSOR DIAL (OFF/60%/COMFORT ZONE/30%): Overrides the ventilation system to high speed once the level of humidity is above the set point. If the ventilation system is in CONT or INTERM mode the ventilation system will automatically return to its original mode once the level of humidity is below the set point. NOTE: By turning the relative humidity Sensor Dial to the OFF position does not turn off the ventilation system. It only deactivates the relative humidity sensor. Comes complete with Relative Humidity Sensor Dial and Speed Control Selector Switch. RELATIVE HUMIDITY SENSOR DIAL (OFF / 60% / COMFORT ZONE / 30%): Overrides the ventilation system to high speed once the level of humidity is above the set point. If the ventilation system is in CONT or INTERM mode the ventilation system will automatically return to its original mode once the level of humidity is below the set point. NOTE: By turning the relative humidity Sensor Dial to the OFF position does not turn off the ventilation system. It only deactivates the relative humidity sensor. RANGE SELECTOR SWITCH (OFF/NORMAL/REDUCED): OFF Sends command to turn off the ventilation system. NORMAL The ventilation system operates on installers set speeds (CONTINUOUS VENTILATION MODE). REDUCE The ventilation system operates at 30% reduction in CONT and 15% in OVERRIDE set speed. NOTE: REDUCE mode will not decrease below the maximum low speed of the ventilation system. Installation of a RD-Series main wall control with your HRV/ERV will improve comfort and may significantly reduce the product s energy use. Page 8

5. OPERATING YOUR WALL CONTROLS (CONTINUED) RD-3P MODEL TM DEHUMIDISTAT PROFESSIONAL Dehumidistat to select the humidity level Range Control (OFF, NORMAL and REDUCED) Mode Control (INTERM and CONT) Green LED light on = OVERRIDE Orange LED light on = CONT/INTERM RD-3D MODEL TM DEHUMIDISTAT DELUXE (MODELS: C3.14, RNC1.0, RNC12 & XDH7.15 only) Dehumidistat to select the humidity level Range Control (OFF, NORMAL and REDUCED) Mode Control (INTERM, RECIRC and CONT) Green LED light on = OVERRIDE Orange LED light on = CONT/INTERM Installation of a RD-Series main wall control with your HRV/ERV will improve comfort and may significantly reduce the product s energy use. Comes complete with Relative Humidity Sensor Dial, Speed Control Selector Switch and Mode Selector Switch. RELATIVE HUMIDITY SENSOR DIAL (OFF/60%/COMFORT ZONE/30%): Overrides the ventilation system to high speed once the level of humidity is above the set point. If the wall control is in CONT or INTERM mode the ventilation system will automatically return to its original mode once the level of humidity is below the set point. NOTE: By turning the relative humidity Sensor Dial to the OFF position does not turn off the ventilation system. It only deactivates the relative humidity sensor. RANGE SELECTOR SWITCH (OFF/NORMAL/REDUCED): OFF Sends command to turn off the ventilation system. NORMAL The ventilation system operates on installers set speeds (CONTINUOUS VENTILATION MODE) REDUCE The ventilation system operates at 30% reduction in CONT and 15% in OVERRIDE set speed NOTE: Reduce mode will not decrease below the maximum low speed of the ventilation system. MODE SELECTOR SWITCH (INTERM/CONT): INTERM When the selector switch is in the INTER position the ventilation system will only run on high speed when there is a request for ventilation. At this time the unit will run on high speed until the level of humidity is below the set point, The T-3 timer has completed its time period or once the cycles per hour has completed its cycle. CONT Provides continuous ventilation. The ventilation system will increase to high when there is a request from one of the wall controls. (Recommended for maximum indoor air quality.) Comes complete with Relative Humidity Sensor Dial, Ventilation Reduction Selector Switch and Mode Selector Switch. RELATIVE HUMIDITY SENSOR DIAL (OFF/60%/COMFORT ZONE/30%): Overrides the ventilation system to high speed once the level of humidity is above the set point. If the wall control is in CONT or INTERM mode the ventilation system will automatically return to its original mode once the level of humidity is below the set point. NOTE: By turning the relative humidity Sensor Dial to the OFF position does not turn off the ventilation system. It only deactivates the relative humidity sensor. RANGE SELECTOR SWITCH (OFF/NORMAL/REDUCED): OFF Sends command to turn off the ventilation system. NORMAL The ventilation system operates on installers set speeds (CONTINUOUS VENTILATION MODE) REDUCE The ventilation system operates at 30% reduction in CONT and 15% in OVERRIDE set speed. NOTE: REDUCE mode will not decrease below the maximum low speed of the ventilation system. MODE SELECTOR SWITCH (INTERM/RECIRC/CONT): INTERM When the selector switch is in the INTER position the ventilation system will only run on high speed when there is a request for ventilation. At this time the unit will run on high speed until the level of humidity is below the set point, The T-3 timer has completed its time period or once the cycles per hour has completed its cycle. CONT Provides continuous ventilation. The ventilation system will increase to high when there is a request from one of the wall controls. (Recommended for maximum indoor air quality.) RECIRC The recirculation mode recycles already-heated ambient air from a selected area and distributes throughout your home. This enables the ventilation system to have an auxiliary air supply automatically during defrost sequence or when RECIRC mode is selected. Page 9

5. OPERATING YOUR WALL CONTROLS (CONTINUED) RD-4P MODEL TM DEHUMIDISTAT PROFESSIONAL Dehumidistat to select the humidity level Range Control (OFF, NORMAL and REDUCED) Mode Control (INTERM and CONT) Cycles per hour (0/0, 20/40 and 30/30) Green LED light on = OVERRIDE Orange LED light on = CONT/INTERM LED light maintenance reminder Comes complete with Relative Humidity Sensor Dial, Speed Control Selector Switch, Mode Selector Switch, Cycles per Hour Selector Switch and Maintenance Reminder Feature. RELATIVE HUMIDITY SENSOR DIAL (OFF/60%/COMFORT ZONE/30%): Overrides the ventilation system to high speed once the level of humidity is above the set point. If the wall control is in CONT or INTERM mode the ventilation system will automatically return to its original mode once the level of humidity is below the set point. NOTE: By turning the relative humidity Sensor Dial to the OFF position does not turn off the ventilation system. It only deactivates the relative humidity sensor. RANGE SELECTOR SWITCH (OFF/NORMAL/REDUCED): OFF Sends command to turn off the ventilation system. NORMAL The ventilation system operates on installers set speeds (CONT and OVERRIDE) REDUCE The ventilation system operates at 30% reduction in CONT and 15% in OVERRIDE set speed NOTE: REDUCE mode will not decrease below the minimum low speed of the ventilation system. MODE SELECTOR SWITCH (INTERM/CONT): INTERM When the selector switch is in the INTER position the ventilation system will only run on high speed when there is a request for ventilation. At this time the unit will run on high speed until the level of humidity is below the set point, The T-3 timer has completed its time period or once the cycles per hour has completed its cycle. CONT Provides continuous ventilation. The ventilation system will increase to high when there is a request from one of the wall controls. (Recommended for maximum indoor air quality.) CYCLES / HOUR SELECTOR SWITCH (0; 20/40; 30/30): 0 The ventilation system operates at the settings of your RD Series wall control. 20/40 The ventilation system cycles automatically for 20 minutes at high speed and returns to previous settings (CONT or INTERM) pending settings on the mode selector switch on your RD series wall control. 30/30 The ventilation system cycles automatically for 30 minutes at high speed and returns to previous settings (CONT or INTERM) pending settings on the mode selector switch on your RD series wall control. NOTE: The ventilation system will go to high speed if a demand from any remote wall control is activated when in the 2nd stage of cycle. (Ex: 40 or 30 minutes) MAINTENANCE REMINDER LIGHT: LED is lit after 90 days consecutive power to the ventilation system. To reset the maintenance LED reminder, put the range selector switch to the OFF position. Installation of a RD-Series main wall control with your HRV/ERV will improve comfort and may significantly reduce the product s energy use. Page 10

5. OPERATING YOUR WALL CONTROLS (CONTINUED) RD-4D MODEL TM DEHUMIDISTAT DELUXE (MODELS: C3.14, RNC1.0, RNC12 & XDH7.15 only) Dehumidistat to select the humidity level Range Control (OFF, NORMAL and REDUCED) Mode Control (INTERM, RECIRC and CONT) Cycles per hour (0/0, 20/40 and 30/30) Green LED light on = OVERRIDE Orange LED light on = CONT/INTERM LED light maintenance reminder Comes complete with Relative Humidity Sensor Dial, Speed Control Selector Switch, Mode Selector Switch, Cycles per Hour Selector Switch and Maintenance Reminder Feature. RELATIVE HUMIDITY SENSOR DIAL (OFF/60%/COMFORT ZONE/30%): Overrides the ventilation system to high speed once the level of humidity is above the set point. If the wall control is in CONT or INTERM mode the ventilation system will automatically return to its original mode once the level of humidity is below the set point. RANGE SELECTOR SWITCH (OFF/NORMAL/REDUCED): OFF Sends command to turn off the ventilation system. NORMAL The ventilation system operates on installers set speeds (CONT and OVERRIDE). REDUCE The ventilation system operates at 30% reduction in CONT and 15% in OVERRIDE set speed. NOTE: REDUCE mode will not decrease below the maximum low speed of the ventilation system. MODE SELECTOR SWITCH (INTERM/RECIRC/CONT): INTERM When the selector switch is in the INTER position the ventilation system will only run on high speed when there is a request for ventilation. At this time the unit will run on high speed until the level of humidity is below the set point, The T-3 timer has completed its time period or once the cycles per hour has completed its cycle. CONT Provides continuous ventilation. The ventilation system will increase to high when there is a request from one of the wall controls. (Recommended for maximum indoor air quality.) RECIRC The recirculation mode recycles already-heated ambient air from a selected area and distributes throughout your home. This enables the ventilation system to have an auxiliary air supply automatically during defrost sequence or when RECIRC mode is selected. CYCLES / HOUR SELECTOR SWITCH (0; 20/40; 30/30): 0 The ventilation system operates at the settings of your RD Series wall control. 20/40 The ventilation system cycles automatically for 20 minutes at high speed and returns to previous settings (CONT, INTERM or RECIRC) pending settings on the mode selector switch on your RD series wall control. 30/30 The ventilation system cycles automatically for 30 minutes at high speed and returns to previous settings (CONT, INTERM or RECIRC) pending settings on the mode selector switch on your RD series wall control. NOTE: The ventilation system will go to high speed if a demand from any remote wall control is activated when in the 2nd stage of cycle. (Ex: 40 or 30 minutes) MAINTENANCE REMINDER LIGHT: LED is lit after 90 days consecutive power to the ventilation system. To reset the maintenance LED reminder, put the range selector switch to the OFF position. TIPS: You can also opt to put your ventilation system on INTERM or OFF mode during the warmer months and run it only at night time once the temperature cools down. Installation of a RD-Series main wall control with your HRV/ERV will improve comfort and may significantly reduce the product s energy use. Page 11

5. OPERATING YOUR WALL CONTROLS (CONTINUED) T-3 MODEL TM PUSH-BUTTON TIMER Comes complete soft touch button and integrated LED indicator light. T-3 PUSH BUTTON TIMER (20/40/60 MINUTES HIGH SPEED EXCHANGE) Press the button once the LED comes on then release, this activates the ventilation system to high speed for 20 minutes. Press the button until the LED blinks 2 times then release, this activates the ventilation system to high speed for 40 minutes. Press the button until the LED blinks 3 times then release, this activates the ventilation system to high speed for 60 minutes. To turn off press button once, this will deactivate T-3 push button time and your ventilation system will return to previous settings. TIPS: The T-3 model push button timer allows the homeowner control of the indoor humidity level in room were excess humidity is produced (Ex: Bathroom, kitchen & laundry room). TIPS: Always leave a small gap when closing curtains and blinds in the winter months, this will allow proper circulation and will reduce or eliminate condensation that occurs when warm air is trapped between window, curtains & blinds. CAUTION: IT IS POSSIBLE (AND NORMAL) TO EXPERIENCE CONDENSATION ON YOUR WINDOWS WHEN DRASTIC CHANGES IN INDOOR OR OUTDOOR TEMPERATURES OCCUR, WHEN EXCESS HUMIDITY IS CREATED OR UPON CLOSING CURTAINS AND BLINDS. 20/40/60 minutes High Speed Exchange Green LED light on = OVERRIDE For more information about how to use the series of ventilation wall controls, please go to www.imperialgroup.ca and download the complete user manual. Page 12

6. TROUBLESHOOTING QUESTION / ITEM DIAGNOSIS / SOLUTION HRV/ERV not running Verify breaker in main electrical panel Verify the HRV or ERV is in the ON position Verify the all wall controls switch on the HRV or ERV are activated to supply power to the unit Unplug HRV or ERV verify if the controller is wired correctly to the connection box on the side of the unit Verify main outlet polarization Air is too dry Increase the humidity level on the controller (Turn towards 60%) Reduce continuous airflow rate Switch ventilation mode from continuous to intermittent Humidifier recommended if heating source is a forced air system Air too humid Suggest continuous operation of HRV or ERV Reduce humidity level on dehumidistat (Turn towards 30%) Increase continuous airflow rate Insufficient ventilation, check capacity Internal source of moisture, e.g. heating wood store in basement, possible leaks or poor insulation R-value and or dryer is venting in basement Vibration or noise Verify that vibration mounting straps, hanging chains or wall bracket is used for hanging the units. Verify that flexible duct connections are use between the HRV or ERV and the rigid duct. Verify that the motors are operating and are not obscured by any debris Insure motor moves freely with turning by hand. Cold air Misplaced supply outlets Defrost no operating correctly The HRV or ERV not properly balanced High airflow on furnace continuous mode Insure HRV or ERV is interlock when integrated with forced air system Contamination or Pollutants Insure proper clearance of ventilation hoods from source of contaminants Condensation Verify that the HRV or ERV is level to insure proper drainage Verify that the duct connection are fix and secured with screws to the HRV or ERV. Verify the cold side duct connections are fully insulated and that vapor barrier is taped to insure a proper seal. Look for signs of crushed section, failing duct straps, puncture vapor barrier, missing insulation. Look for sign of water accumulation/leakage/dripping Verify that the drain connection is not kinked; the P trap is not to close to unit or obscured with debris. 7. MAINTENANCE OF THE VENTILATION SYSTEM (PH, PE, SOLACE, DH & SS SERIES) ROUTINE MAINTENANCE SEVEN-STEP MAINTENANCE SCHEDULE With routine preventative maintenance, you can avoid unnecessary problems, ensure the effectiveness of your HRV, and prolong its life. For additional specific instructions, refer to your HRV operating manual or ask the contractor who installed or services the HRV to demonstrate the proper maintenance procedures. WARNING: BE SURE TO DISCONNECT THE ELECTRICAL POWER BEFORE SERVICING YOUR SYSTEM 1. Clean or replace air filters. Filters, which are located within the HRV should be cleaned every two to three months. Filters should be vacuumed first, then washed with a mild soap and water. Most washable filters will last several years before needing to be replaced. 2. Clean the exterior intake and exhaust vents of obstructions.check the outside vents regularly to ensure that the screen openings are not obstructed by grass, bushes, leaves, snow or other debris. 3. Clean and inspect the heat-exchange core and aluminum louvers (Ref. Fig. 17.1 for proper orientation of louvers). Twice a year and clean it as required (consult your owner s manual for instructions on inspecting and cleaning the core). A build-up of dust and dirt can restrict airflow and reduce the efficiency of your HRV/ERV. After inspection and cleaning, make sure the core is replaced right-side-up. 4. Clean the condensate drain and pan. Twice a year, check the condensate drain and tubing to ensure that they are open and free-flowing. The tubing can be disconnected for cleaning. The condensate drain must have a trap in the tubing that traps a quantity of water to prevent air from entering the HRV/ERV via this tubing 5. Service the fans. The fans on the HRV/ERV s are designed to operate continuously without lubrication. Inspect the blower fans periodically for dirt on the blades, and remove it by gently brushing the blades or using a vacuum cleaner. For proper orintation of louvers. (Solace & PH ES Series only) 6. Clean the grilles and inspect the ductwork. Clean the grilles when they are dusty. At least once a year, visually inspect the ductwork leading to and from the HRV. Damaged ducts can lead to condensation problems, including wet insulation, water on the floor and, ice build-up. If the insulation itself is damaged. 7. Arrange for an annual servicing. Your HRV/ERV should undergo annual general servicing by a certified contractor and who is familiar with your HRV. If possible, have your furnace and HRV serviced at the same time; this will result in less inconvenience and cost than two separate visits. Page 13

Page 14

WARRANTY PROCEDURES AND CONDITIONS The following advisory is intended to explain Imperial Air Technologies warranty procedures with regard to Imperial IAQ products. Note observing proper warranty procedures will expedite the processing of warranty claims and will help reduce the number of claims that are denied. Please take note of the following warranty procedure to avoid the denial or a reduction in the reimbursement to your warranty issues or claims. NO CLAIMS WLL BE ACCEPTED WITHOUT AN RGA NUMBER STANDARD WARRANTY PROCEDURES Upon notice of warrantable failure, information should be gathered specific to the cause and results of the failure. Warranty claim request must be filed within 30 days of failure. Contact Imperial Air Technologies Customer Service/Technical Support Line at 1-888-724-5211 and explain the situation, including model and serial number of the machine. We will advise as to proper procedures to either repair or replace as necessary and the warranty coverage available. Order the parts required to replace the defective parts after authorization by faxing your order to 1-506-388-4633. Important the unit model as well as the serial number must be stated to insure replacement parts are accurate. Imperial Air Technologies Warranty Claim Form or similar form must be filled with the specific following information: model, serial number, date installed, installer, distributor and a detailed report on the failure. Retain all defective parts (well identified) with the claim report, warranty claim form. An (RGA) Return Goods Authorization Number must be obtained before any parts or claims are returned or authorized to be scrapped in the field. Call Imperial Air Technologies Customer Service Line at 1-800-561-3100 for an RGA Number. Invoice/Imperial Air Technologies Warranty Claim Form or similar for warranty replacement parts must be accompanied by the model and serial number of the defective unit. Notice: The MODEL NUMBER, SERIAL NUMBER and RGA NUMBER must be supplied at all times. If failing to comply in regards to the above procedures, no warranty claims or credit will be issued. IMPERIAL AIR TECHNOLOGIES LIMITED WARRANTY ON COMPONENTS Imperial Air Technologies warrants the components (controls, sensor & electronics) to be free from defects in material and workmanship. If a defect is found within the models warranty period from date of original installation of the product (whether or not actual use begins on that date). Imperial Air Technologies will provide a new or remanufactured part, at Imperial Air Technologies discretion, to authorize replacement of defective part, without charge for the part itself. LIFETIME LIMITED WARRANTY ON POLYPROPYLENE HEAT RECOVERY CORE Imperial Air Technologies warrants the polypropylene heat recovery core against defects in material and workmanship for a lifetime from the date of original installation. Imperial Air Technologies will provide a new or remanufactured part, at Imperial Air Technologies discretion, to authorize replacement of defective part, without charge for the part itself. 5-YEAR LIMITED WARRANTY ON ENTHALPY ENERGY RECOVERY CORE Imperial Air Technologies warrants the enthalpy energy recovery core against defects in material and workmanship for a period of five years from the date of original installation. Imperial Air Technologies will provide a new or remanufactured part, at Imperial Air Technologies discretion, to authorize replacement of defective part, without charge for the part itself. 1-YEAR LIMITED WARRANTY Imperial Air Technologies warrants replacement parts that have been replaced after the standard period of the previous limited warranty, to be free from defects in material and workmanship. If a defect is found within one year from date of original installation of replacement part, (whether or not actual use begins on that date) Imperial Air Technologies will provide a new or remanufactured part, at Imperial Air Technologies discretion, to authorize replacement of defective part, without charge for the part itself. WARRANTY CONDITIONS Warranties apply only to Imperial Air Technologies products installed in their original location. Installation, use, care, and maintenance must be normal and in accordance with instructions contained in the Owner s Manual and service information. Defective parts must be returned to the distributor through a registered servicing dealer for credit. All work shall be performed by a certified technician. IMPERIAL AIR TECHNOLOGIES WILL NOT BE RESPONSIBLE FOR Normal maintenance, installation, including filter cleaning and/or replacement, damage or repairs required as a consequence of faulty installation, misapplication, abuse, improper servicing, unauthorized alteration or improper operation. Damage as a result of floods, winds, fires, lightning, accidents, corrosive environments or other conditions beyond the control of Imperial Air Technologies. Parts not supplied or designated by Imperial Air Technologies, or damages resulting from their use 5-Years 2-Years MODELS PH7.15, PH7.15ES, XPH1.5, PE7.15, PH10.22, PH10.22ES, XPX2.0, PE10-22, XDH7.15, C3.14HRV, SS3.80 HRV, SS3.80ERV RNC12, RNC1.0, RNC1.5, RNC2.0, RNC2.0ES LIMITED WARRANTY ON VENTILATION MOTORS Imperial Air Technologies warrants the ventilation motors against defects in material and workmanship within the models warranty period from the date of original installation. Imperial Air Technologies will provide a new or remanufactured part, at Imperial Air Technologies discretion, to authorize replacement of defective part, without charge for the part itself. 10-Years 5-Years 2-Years MODELS PH7.15, PH7.15ES, XPH1.5, PE7.15, PH10.22, PH10.22ES, XPX2.0, PE10-22, XDH7.15 C3.14HRV, SS3.80HRV, SS3.80ERV RNC12, RNC1.0, RNC1.5, RNC2.0, RNC2.0ES NOTICE: None of these warranties include labor or other costs incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling of either defective parts, or replacement parts, or new units. H/ERV_Warranty_OCT2017 Page 15

101078 - OCT2017 Page 16 Imperial Air Technologies 480 Ferdinand Blvd., Dieppe, NB E1A 6V9 1-888-724-5211 Fax 506 388-4633 www.imperialgroup.ca