Super WISE. System product for Swegon s system for demand-controlled ventilation

Similar documents
Installation Instructions for the TBLZ-2-66 control box. for controlling two air handling units (Twin Function) GOLD RX

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Wilo CO-Helix Booster Systems. Product Presentation July, 2017

Demand-controlled Ventilation Leading edge products for demand-controlled ventilation

EC-BOS-602/616 AX Security

Energy Savings with Direct Digital Control

IntesisBox BACnet/IP Server - Notifier ID3000 series

CoolTeg Plus XC40. AC-TXC Direct expansion Air-conditioning unit with integrated compressor

PARAGONTM Comfort module for hotel rooms and hospital wards

AIS750 Series Alarm Annunciator

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

Control System Structure

ADRIATIC VF. Active chilled beam with cooling, heating and ventilation QUICK FACTS

Honeywell SLATE ICM Platform

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

System technology. Demand controlled ventilation WISE.

ECL Comfort 310 controller, Remote Control Units ECA 30 / 31 and Application keys

CAREL heatersteam Electric Element Steam Humidifiers

DAIKIN Air Handling Unit Modular

Installation Manual COPYRIGHT NOTICE

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

PLC / HMI Modbus (Slave) Addressing

U C S AND AUTOMATION SYSTEMS

The integral solution for. Air Handling Units. Technology & Evolution

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

Millennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc.

New control technologies for residential ventilation, ISH Klaus Lang, PAD Residential Ventilation, Systemair Group

Manual for the integration in BMS/GTC

THE CHANGE IN GEAR ENGINEERING

Labkotec Ice Detector

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

ACTIVE INFRARED BARRIER

Fire damper actuators. Selection and integration.

2019 Price List. Company Overview. Gateways. Super Gateways. paragonrobotics.com GW3 GW10

Advanced Facility Air-Management Technology

AIRSYS-P-SC-MOBILECOOL-INDOOR-E1507V01.2 MOBILECOOL-INDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.4~13.

Process Alarm Solutions

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

Tried, true, and trusted for over 40 years. EL Series Electrode Steam Humidifier. Humidification and Evaporative Cooling. humidity.

Lennox Climatic 50 and BMS Modbus, Trend or BACnet.

babytel babybox INSTALLATION MANUAL Connection and Setup

lighting management standalone sensors

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

Intelligent Chiller Manager (icm)

NEW. lighting management - stand alone detectors, power packs. Passage detection - Infrared technology. Detectors with power packs

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

AIRSYS-P-SC-MOBILECOOL-OUTDOOR-E1509V01.5 MOBILECOOL-OUTDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.5kW-13.

ModBus DE-1 INSTALLATION AND USER MANUAL

FS Mircom FX2000 Fire Alarm Panel

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

WEBs AX Security. Integrated Security With Simple, Web-Based Management

GasGard 100 Control System

DAP III Zone Master User s Guide

BMS Specification. Lonix Ltd.

Application Manual LT-6617 Rev. 1 July 2017

opti-visor ultra-efficient chiller plant automation Typical specification

ADAPT Parasol EX a. Installation - Commissioning - Maintenance ADAPT Parasol EX a - m A1, B1

ADAPT Parasol EX. Energy-saving, suspended comfort module QUICK FACTS

Ventilation in balance

IPSUM OPTIMIZATION SYSTEM» DEMAND CONTROLLED VENTILATION OVERVIEW

Cultivator & Hybrid Cultivator

Virginia Tech Standards for Building Automation System


Integrated Process Solutions. Series 49. Thermal Management System

Helios in a new dimension.

Compact. Efficient. TROX.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

Home center Interface Server. Technical sheet

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

PARAGON. Compact comfort module. Key figures

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

B.E.G. LUXOMAT net. DALISYS Intelligent Lighting Control and more

TTC. TTC Active supply air diffuser. Product description. Introduction SUPPLY AIR DIFFUSER - ACTIVE [CEILING MOUNTED] Simplicity

F series close control air conditioners exploit the indirect FREE COOLING system with adiabatic cooling to ensure high system energy savings.

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

A36D/TPSD Modbus TCP SCADA INTERFACE INSTRUCTIONS

DEMAND CONTROLLED HOME VENTILATION HCC 2 Designed to suspended ceiling installation

ADAPT Parasol EXb. Installation. Installation Commissioning Maintenance A1, B1

Salusfin Smart heating control: Installation Guide

56W Vapor Proof LED Fixture V Dimmable - DALI Network lms - IP67 - Outdoor Applications

1 Application Note Bosch Security Sys Sy tems m Bosch Security Systems Smart Safety Link -

MC4000 Series Advanced Solid State Dual Unit Lead/Lag Controller with Ethernet Remote Communication Option

Hoval Indoor Climate Systems Control systems

CONDAIR EL. Electrode boiler steam humidifier Easy maintenance with replaceable cylinders. Humidification and Evaporative Cooling

SECTION Fluorescent Dissolved Oxygen Measuring System

Reference Guide for Microprocessor Controller

Liebert LDMF Distribution Monitoring. User Manual

SAUTER flexotron800 V2 Ventilation V3.3. manual P P

ME 3011C / Alarm Indication / Quick Reference Guide

TTC. TTC Active supply air diffuser. Product description SUPPLY AIR DIFFUSER - ACTIVE [CEILING MOUNTED] Introduction. Simplicity

The ultimate fresh air solution.

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

SmartVFD HVAC and BYPASS

BLAUAIR AUTOMATIC CONTROL SYSTEM

Rotary Screw Compressors. SK Series With the world-renowned SIGMA PROFILE Flow rate 0.53 to 2.70 m³/min, Pressure 5.5 to 15 bar

Measuring Recording Online Monitoring Regulation Alarming

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

Transcription:

System product for Swegon s system for demand-controlled ventilation Quick facts Pressure optimisation of the supply air and extract air fans Addition and subtraction of flows within a zone Handles 80 zone dampers distributed among 10 zones and 60 rooms/zone, a total of 600 rooms Gateway to intelligent building automation Communication via Modbus RTU, Modbus TCP, BACnet TCP Integrated web page for supervising airborne and waterborne indoor climate systems down to room level 1

on off 1 2 Technical description Operation The is a communication unit which via Modbus RTU communicates on one hand with Swegon s air handling unit, on the other with Swegon s underlying products that are included in the WISE and CONDUCTOR systems. has three main functions: Pressure optimisation of air handling units Gateway to intelligent building automation Web page for supervising ventilation/cooling systems Pressure optimisation of air handling units replaces Swegon s previous product, CONTROL Optimize, for the optimisation of a ventilation system. Super WISE has knowledge of the position of each zone damper, and optimizes the pressure of the air handling unit so that at least one zone damper will always be at least 90% open. This reduces the power usage of the air handling unit by up to 25% and also contributes to making the ventilation system quieter. See Figure 1. Gateway to intelligent building automation A ventilation system intended for communication with should be wired and addressed (Modbus ID) according to Swegon s instructions. This way all the component products with logic equipment will fall in under the in a logical tree structure. The structure is also reflected as a "flat" structure, with which an intelligent building automation can communicate. handles the following protocols: Modbus RTU, Modbus TCP and BACnet TCP. Detailed information about the communication structure and parameter lists are available for downloading at www.swegon.com. See Figure 2. Figure 1. Pressure optimisation of air handling unit 1. 2. Modbus RTU 3. amper 4. 2-10 V signal from DETECT Pressure Intelligent building automation Figure 2. Modbus structure,. 2

Web page for supervising ventilation/climate systems also contains a web page that presents the entire underlying ventilation/climate system in a clear and easy-to-understand manner. Zone and room illustrations present the actual values and the set points. Changeable parameters for all the room and zone products are easy to access in the web structure. Manual for the web page is available for downloading at www.swegon.com. Figure 3. Web page, for the supervision of ventilation/climate systems with room function and parameter adjustment respectively, which presents read and write values. 3

Project planning The super WISE is well-suited for both large and small ventilation systems. If the air handling unit is centrally located, one is used per air handling unit to be able to manage optimising the pressure of the air handling unit. When is used in combination with decentralised ventilation, the communicates with all the air handling unit ventilation/climate systems, however not with each air handling unit. can communicate with only one air handling unit. Commissioning With installed in the system, commissioning becomes much simpler. Using a computer and the integrated web page, you obtain a clear picture of the entire system such as pressure drop, airflows and damper blade positions. Installation can be mounted on a wall. Four screws are used for this purpose. is well-suited for installation in a fan room. ETHERNET Router Figure 4. in combination with decentralised and centrally located air handling units respectively. 4 Swegon reserves the right to alter specifications. 20121114 www.swegon.com

Connections A computer with web browser and support for Java applications is required for managing and operating Super WISE. The computer can either be connected directly to with a cross-connected CAT5 cable with RJ45 connectors or to a network (hub, switch or router) with a straight (not cross-connected) CAT5 cable. Connect the cable to the outlet marked ETHERNET in the. See Figure 5. is delivered from the factory with a fixed IP address. The first time you communicate with the Super WISE, use the Golden Gate Config software that can be downloaded from www.swegon.com. For more detailed information about how to wire to underlying systems, intelligent building automation and air handling unit, refer to the installation instructions. Detailed information about communication with and using the web page can be read in the web page manual that is available for downloading at www.swegon.com. Technical data Supply voltage 230 V AC, max. 10 A Enclosure class IP 65 Ambient temperature at relative humidity Dimensions (W x H x D) Weight Ordering key Product -20 +40 C 10 95% 300 x 400 x 120 mm 8000 g Communication unit a Version Figure 5. Wiring. 5