Q7300L Series 2000 Commercial Thermostat Subbases

Similar documents
Q7300H Series 2000 Commercial Thermostat Subbases

Q7100A,C,D Thermostat Subbases

Q7100A,C Thermostat Subbases

T7200D,E Series 2000 Commercial Microelectronic Thermostats

T8411R Electronic Heat Pump Thermostat

CAUTION: ELECTRICAL HAZARD

T8600D Chronotherm IV Deluxe Programmable Thermostats

T8624D Chronotherm IV Deluxe Programmable Multistage Thermostats

T8602C Chronotherm IV Deluxe Programmable Thermostats

T8611M Deluxe Programmable Heat Pump Thermostats

L7224A,C; L7248A,C,L Oil Electronic Aquastat Controllers

Deluxe Programmable Heat Pump Thermostat T8611M

Deluxe Programmable Thermostats

L8151A Triple Aquastat Relay

T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat

T8401C Electronic Thermostats

T8112C,DElectronic ProgrammableThermostats

T7047C,G,H Remote Space Sensors

T874 Multistage Thermostat and Q674 Subbase

T7100D Microelectronic Conventional Thermostat

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

R8182D,E,F,H,J Combination Protectorelay Primary Control and Aquastat Controller

Commercial Touchscreen Thermostat

tcu.z Commercial Programmable Thermostat Installation Instructions

T8524 Deluxe Electronic Thermostat

T6984F,G Electronic Floating Control Thermostats

T7351 Commercial Programmable Thermostat

CT2700 An Electronic Round Programmable Thermostat

R8888A,B Hydronic Circulator Zone Panels with Priority Control

T8011R Programmable Heat Pump Thermostat

T7350 Commercial Programmable Thermostat

T7300F Multistage Conventional or Heat Pump Programmable Commercial Thermostat

M6063A Compact Rotary Mixing Valve Actuator

T4098A,B Deluxe Electric Heat Thermostats

L4188A,B; L4189A,B; L6188A-C; L6189A-C Aquastat Controllers

W8703A Damper Interface Module

T4398A,B High Performance Electric Heat Thermostats

T6984 A,D,E Electronic Floating Control Thermostats

CT500 Electronic Thermostat

T7300F Series 2000 Commercial Microelectronic Conventional or Heat Pump Thermostat

T834C Heating-Cooling Thermostat

Oil-Fired Furnace Single Stage Heat Pumps No- Auxiliary Heat. Electric Air Conditioning

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

T7984 A,B,C Electronic Modulating Control Thermostats

ACONT600AF11MA Programmable Comfort Control

TCONT602AF22MA. Programmable Comfort Control. Installation Instructions 18-HD37D1-1

heat (2 heat/1 cool).

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.

T8090A/Q682B Heating, Cooling, and Heating-Cooling Thermostat, Wallplate and Subbase

T6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats

T8000C Programmable Thermostat

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page.

L7224A,C; L7248A,C,L Oil and Electric Boiler Electronic Aquastat Controllers

T4360G, T6360D, T6360E Line Voltage Thermostat

Honeywell/36. Programmable Thermostat OWNER S GUIDE

T8400C and T8401C Electronic Thermostats

T874A-F Multistage Thermostats; Q674A-G Subbases by Honeywell

PS4000 and PS5000 Touchscreen Programmable Thermostat Installation and Owners Manual Robertshaw 01/

INSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide.

VisionPRO 8000 with Wi-Fi

T6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats XE88/XE100 SERIES

Honeywell CT3550 PROGRAMMABLE THERMOSTAT. Table of Contents OWNER S GUIDE

MODEL Day Programmable 1 Heat / 1 Cool Electric / Gas

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page.

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page.

Table 1. Serie of Digital Room Thermostats.

T8400C Universal Electronic Thermostats

T8112 Programmable Thermostat

ARGO AR SERIES CONTROLS

CT1001/CT1002 Touchscreen Programmable Thermostat

EWT-3102/EWT-3103 Touchscreen Programmable Thermostat

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

Q7800H Integrated Burner Control Subpanel

This thermostat provides electronic control of 24 VAC single-stage and multi-stage

T8034C Heating/Cooling Thermostats

T8400C Electronic Thermostat

T7351 Commercial Programmable Thermostat FOR SINGLE- OR MULTI-STAGE CONVENTIONAL/HEAT PUMP SYSTEMS

Honeywell/20 Programmable Thermostat

C6097A,B Pressure Switches

CT2800 Programmable Thermostat

Q382A,B Pilot Burners

T6590 Series FAN-COIL CONTROLLER FEATURES APPLICATIONS PRODUCT DATA

C7232A,B Sensor and Controller

T6590 Series FAN-COIL CONTROLLER

Description / Applications

T8132C Programmable Thermostats

Must be installed by a trained, experienced technician

T8112C,D Electronic Programmable Thermostats

Honeywell CT3611 PROGRAMMABLE THERMOSTAT. Table of Contents OWNER S GUIDE

MagicStat CT3300 Programmable Thermostat

Home and Building Control Home and Building Control Helping You Control Your World

T7079A,B Solid State Remote Temperature Controllers

Honeywell CT8602 PROGRAMMABLE THERMOSTAT

Heating/Cooling Thermostat and Subbase Package T8196A/Q682A

1025NC Single Stage Heat Only

T4398A,B Precision Electric Heating Thermostat

RM7838A 7800 SERIES Relay Modules

VisionPRO IAQ Total Home Comfort System

Erie WA300. Application. Features. Two Zone Hydro-Air Relay General Instructions

Transcription:

Q700L Series 2000 Commercial hermostat Subbases INSALLAION INSRUCIONS APPLICAION he Q700L hermostat Subbase is used with the 700D,F hermostat to provide electronic control of commercial 24 Vac single zone HVAC equipment. he 700/Q700L is designed for heat-cool applications using a valve and valve actuator combination for hydronic heating. See able. It can also be used to control singlestage conventional heating systems. It provides two-speed fan control. erminals are provided for the 7047 Remote Sensor or the 747 Remote Sensor and Override Module. LEDs on the thermostat are prewired and labeled to indicate heat and cool operation. See Fig. 9 and 0 for hookup drawings. Refer to form 6-455 for installation and operation of the 700/Q700. able. Valve and Valve Actuator Combinations. Valve Model V50A, C V50F, G V50A, C V50F IMPORAN he valve will not close if the wrong valve and valve actuator combination is used. Electrical Rating: 20 to 0 Vac, 50/60 Hz. System Current : 6 VA maximum at 0 Vac, 50 or 60 Hz. Output Relay Current: See able 2. Valve Actuator Model ML7984A09 ML7984A00 ML7984A09 ML7984A00 able 2. Maximum Amps at 0 Vac. Relay Running (A) Inrush (A) Fan.6.5 Heat.6.5 Cool.6 7.5 Auxillary (Economizer).6.5 emperature: Ratings: Operating Ambient: 40 F to 0 F (4 C to 4 C). Shipping: -0 F to +50 F (-4 C to +65 C). Display Accuracy: + F (+0.5 C). Setpoint: Range: 45 F to 95 F (7 C to 5 C). Differential: 2 F ( C). Humidity Ratings: 5% to 90% RH, noncondensing. RECYCLING NOICE If this control is replacing a control that contains mercury in a sealed tube, do not place your old control in the trash Contact your local waste management authority for instructions regarding recycling and the proper disposal of the old thermostat. INSALLAION When Installing this Product. Read these instructions carefully. Failure to follow the instructions can damage the product or cause a hazardous condition. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application.. Installer must be a trained, experienced service technician. 4. After completing installation, use these instructions to check out the product operation. U.S. Registered rademark Copyright 996 Honeywell Inc. All Rights Reserved X-XX UL 62-0-2

Q700L SERIES 2000 COMMERCIAL HERMOSA YES NO NO 5 FEE (.5 MEERS) NO M482A Fig.. ypical location of thermostat or remote-mounted sensor. Location Subbase without Remote-Mounted emperature Sensor Install the thermostat about 5 ft (.5m) above the floor in an area with good air circulation at average temperature. See Fig.. Do not install the thermostat where it can be affected by: drafts, or dead spots behind doors and in corners. hot or cold air from ducts. radiant heat from sun or appliances. concealed pipes and chimneys. unheated (uncooled) areas such as an outside wall behind the thermostat. Subbase with Remote-Mounted emperature Sensor(s) If only the remote-mounted temperature sensor(s) is used to sense and control room temperature, then install the thermostat in an area that is accessible for setting and adjusting the temperature and settings. If both the subbase and remote-mounted temperature sensor(s) are used to sense and control room temperature, then install the subbase about 5 ft above the floor in an area with good air circulation. Do not mount the sensor(s) where it can be affected by: drafts, or dead spots behind doors and in corners. hot or cold air from ducts. radiant heat from sun or appliances. concealed pipes and chimneys. unheated (uncooled) areas such as an outside wall behind the thermostat. If more than one remote sensor are required, they must be arranged in a temperature averaging network consisting of two, three, four, five or nine sensors. See Fig. 2 through 6. IMPORAN o avoid electrical interference, which can cause erratic performance, keep wiring runs as short as possible and do not run thermostat wires adjacent to the line voltage electrical distribution systems. Use shielded cable (Belden type 8762 or equivalent for 2-wire and Belden type 8772 or equivalent for -wire). he cable shield must be grounded only at the controlled equipment case. 7047G 7047G Install the remote-mounted sensor(s) about 5 ft (.5m) above the floor in an area with good air circulation at average temperature. See Fig.. M488 Fig. 2. wo 7047G Sensors providing temperature averaging network for 700/Q700 hermostat/subbase. 62-0 2 2

Q700L SERIES 2000 COMMERCIAL HERMOSA 7047C 7047C 7047C 7047C 7047G 7047C 7047C 7047C 7047C M489 7047C 7047C 7047C Fig.. wo 7047C Sensors and one 7047G Sensor providing temperature averaging network for 700/ Q700 hermostat/subbase. M4842 7047C 7047C 7047C Fig. 4. Four 7047C Sensors providing temperature averaging network for 700/Q700 hermostat/subbase. 7047C M4840 Fig. 6. Nine 7047C Sensors providing temperature averaging network for 700/Q700 hermostat/subbase. Mounting Subbase he subbase mounts horizontally on the wall or a 2 in. x 4 in. wiring box. Position the subbase horizontally on the wall or on a 2 in. x 4 in. wiring box.. Position and level the subbase or wallplate (for appearance only). he thermostat functions properly even when not level. 2. Use a pencil to mark the mounting holes. See Fig. 7.. Remove the subbase or wallplate from the wall and drill two /6 inch holes in the wall (if drywall) as marked. For firmer material such as plaster or wood, drill two 7/2 inch holes. Gently tap anchors (provided) into the drilled holes until flush with the wall. 4. Position the subbase over the holes, pulling wires through the wiring opening. 5. Loosely insert the mounting screws into the holes. 6. ighten mounting screws. WALL 7047G 7047G WIRES HROUGH WALL 7047G WALL ANCHORS (2) 7047G 7047G MOUNING HOLES Fig. 5. Five 7047G Sensors providing temperature averaging network for 700/Q700 hermostat/subbase. M484 LEDS Fig. 7. Mounting the subbase. MOUNING SCREWS M027 62-0 2

Q700L SERIES 2000 COMMERCIAL HERMOSA WIRING All wiring must comply with local electrical codes and ordinances. Follow equipment manufacturer wiring instructions when available. Refer to Fig. 9 and 0 for typical hookups. A letter code is located near each terminal for identification. See able for terminal descriptions and system action. able. erminal Descriptions and Conditions. Standard erminal Designations ypical Connection Function erminal ype A, A2 Damper Control Relay. input, output 24V powered contact BM ML7984 Actuator connection. No call for heat, valve closed during occupied periods and open during unoccupied periods. output C, C2, C, C4, C5 Communication input for 747. FC Fan control ransformer. input GH High speed fan output. Activated during calls for cooling. output 24V powered contact GL Low speed fan output. Activated on calls for heat and fan On selection. P, P2 Pump Interlock Relay. Operates circulator pump in hydronic heat or energizes conventional heat system. output input, output 24V powered contact 24V powered contact R 24V System ransformer input RM ML7984 Actuator connection. No call for heat, valve closed. Call for stage heat, valve approximately onehalf open. Call for stage 2 heat, valve fully open., Remote sensor input for 7047 or 747. X Heating transformer common input Y Cool call 24V output on Y CAUION Disconnect power before wiring to prevent electrical shock or equipment damage.. Loosen the terminal screws on the subbase and connect the system wires. See Fig. 8. IMPORAN Use 8-gauge, solid-conductor color-coded thermostat cable for proper wiring. If using 8- gauge stranded wire, no more than ten wires can be used. Do not use larger than 8-gauge wire. 2. Securely tighten each terminal screw.. Push excess wire back into the hole. 4. Plug the hole with nonflammable insulation to prevent drafts from affecting the thermostat. NOE: After wiring, check that all connections are tight and secure. See Fig. 8. Loose or intermittent wire connections cause inconsistent system operation. FOR WRAPAROUND INSERION SRIP 7/6 IN. ( MM). FOR SRAIGH INSERION SRIP 5/6 IN. (8 MM). Fig. 8. Proper wiring technique. M4826 62-0 2 4

Q700L SERIES 2000 COMMERCIAL HERMOSA ypical Wiring Hookups AS AS 7 R A P RM BM A2 P2 Y X GH GL FC C5 C4 C C2 C 8 2 DISCHARGE AIR SENSOR ML7984 9 VALVE ACUAOR 5 R 6 B W 5 DAMPER CONROL PUMP INERLOCK COOLING HIGH SPEED FAN LOW SPEED FAN CA5 CA4 CA CA2 CA 747 REMOE COMFOR ADJUS MODULE GND 4 L (HO) L2 RANSFORMER FAN RANSFORMER L (HO) L2 6 2 4 5 POWER SUPPLY. PROVIDE DISCONNEC MEANS AND OVERLOAD PROECION AS REQUIRED. INDEPENDEN FAN RANSFORMER IS OPIONAL. JUMPER FC O R WHEN SINGLE RANSFORMER IS USED. REFER O ML7984 INSRUCIONS FOR ERMINAL CONNECIONS. 7047 HAS - ERMINALS ONLY. 80 2W RESISOR MUS BE INSALLED AS SHOWN. 6 CONNEC GND O EARH GROUND. 7 DISCHARGE AIR SENSOR IS ONLY COMPAIBLE WIH 700F HERMOSA. 8 JUMPER GH AND GL FOR SINGLE SPEED FAN. 9 SE HE DIP SWICHES ON HE ML7984 O MECHANICAL SERIES 90 O USE WIH Q700L M4950B Fig. 9. Q700L hookup for two-stage heating with three-position ML7984 Valve Actuator/V50 Valve and one-stage cooling. R A P FC GH 4 GL P2 A2 Y BM RM X C5 C4 C C2 C L (HO) L2 HIGH-SPEED FAN LOW SPEED FAN PUMP INERLOCK DAMPER CONROL COOLING CA5 CA4 CA CA2 CA 2 747 REMOE COMFOR ADJUS MODULE GND 2 4 POWER SUPPLY. PROVIDE DISCONNEC MEANS AND OVERLOAD PROECION AS REQUIRED. REFER O 747 INSRUCIONS FOR ERMINAL CONNECIONS. 7047 HAS - ERMINALS ONLY. CONNEC GND O EARH GROUND. JUMPER GH AND GL FOR SINGLE SPEED FAN. M494C Fig. 0. Q700L hookup for single-stage conventional heating systems with single-stage cooling. 5 62-0 2

Q700L SERIES 2000 COMMERCIAL HERMOSA Mounting hermostat on Subbase Mount the thermostat on the subbase after the subbase is installed.. Engage tabs at the top of the thermostat and subbase. Fig.. 2. Press lower edge of case to latch. A. ENGAGE ABS A OP OF HERMOSA AND OR WALLPLAE. NOE: o remove the thermostat from the wall, first pull out at the bottom of the thermostat; then remove the top. IMPORAN Refer to the thermostat installation instructions for Installer Setup, Settings, Installer System est and roubleshooting information. B. PRESS LOWER EDGE OF CASE O LACH. M4824A Fig.. Mounting thermostat on subbase. 62-0 2 6

Q700L SERIES 2000 COMMERCIAL HERMOSA OPERAION Mode System Setting able 4. 700 hermostat/q700l Subbase Sequence of Operation. Fan Setting a Equipment Call Action Occupied Any Auto hermostat in Occupied mode. Damper control relay energized. Occupied On Depends on last system. If cool is the last system, then call is for high speed fan. When heat is the last system, then call is for low speed fan. Occupied Heat Auto Stage heat Heat LED activated. In hydronic applications, ML7984 approximately one-half open. Pump interlock relay activated to energize circulator pump. In conventional applications, stage heat activated. Low speed fan activated. Occupied Heat Auto Stage 2 heat In hydronic applications, ML7984 is fully open. In conventional systems, no action. Occupied Cool Auto Stage cool Cool LED activated. Cooling relay activated. High speed fan activated. Unoccupied Any Any hermostat in Unoccupied mode. Damper control relay de-energized. Unoccupied Any On hermostat in Unoccupied mode. System fan operates at appropriate speed with call for heat or cool equipment. a Low speed fan is activated in the heat mode and high speed fan is activated in the cool mode. Loads Energized A2 GL or GH A2, GL, RM, P2 A2, GL, RM, BM, P2 A2, GH, Y Remote emperature Sensing and Override he subbase can be used with the 747 Remote Sensors to sense temperature and provide the Occupied mode. he subbase also can be used with the 7047 Remote Sensors if remote occupied control is not required. 7 62-0 2

Q700L SERIES 2000 COMMERCIAL HERMOSA Home and Building Control Honeywell Inc. Honeywell Plaza P.O. Box 524 Minneapolis, MN 55408-0524 Home and Building Control Honeywell Limited-Honeywell Limitée 55 Gordon Baker Road North York, Ontario M2H N7 Helping You Control Your World 62-0 2 J.H. Rev. 7-97 8 www.honeywell.com/building/components