HVAC HEATING PRODUCTS

Similar documents
HVAC HEATING PRODUCTS

Gas-Fired Heating Equipment

HVAC HEATING PRODUCTS Application Manual

BTUC-4 TUBULAR GAS-FIRED UNIT HEATERS

GQVC-12 HVAC EQUIPMENT. GAS-FIRED INDOOR HEATING EQUIPMENT A complete line of effi cient heating solutions for large, open spaces.

Product Catalog Gas Heating Products: Indoor and Outdoor Units

SUBMITTAL SCHEDULE & DATA

bring value to your space

HVAC EQUIPMENT for Residential, Industrial & Commercial Applications GACP-22

GAS-FIRED POWER VENTED UNIT HEATERS PROPELLER & BLOWER MODELS

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models

FEATURES AND BENEFITS

SUH-8 UNIT HEATERS. High Efficiency Heating Equipment

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

HVAC EQUIPMENT for Residential, Industrial & Commercial Applications GACP-20

Gas-Fired Indoor and Outdoor Duct Furnaces

HIGH EFFICIENCY GAS-FIRED, UNIT HEATER LIST PRICES

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

Installation, Operation and Maintenance

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

KIC Air Curtains. Technical Guide

Indirect Gas-Fired Make-Up Air

Gas-Fired Unit Heaters Commercial & Industrial

AUGUST, High-Efficiency Condensing Gas-Fired Separated Combustion Unit Heaters

AHC-2. OUTDOOR AIR HANDLERS Application Manual

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

TECHNICAL SPECIFICATIONS

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

INFRARED RADIANT HEATERS

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

GARAGE / WORKSHOP INFRARED HEATERS

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

TUBULAR GAS-FIRED BLOWER STYLE UNIT HEATER

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS

RG7D 1-Stage Heat Series

G6RC Series TECHNICAL SPECIFICATIONS

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

Gas-Fired Indoor and Outdoor Duct Furnaces

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

ADF/ADFH 300 and 500

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

SEPARATED COMBUSTION TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Downflow/Horizontal Right Induced Draft Gas Furnace

INDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

Upflow/Horizontal Condensing, Gas-Fired Furnace

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

TECHNICAL SPECIFICATIONS

Gas-Fired Unit Heaters Commercial & Industrial

MERIT SERIES Downflow

Ruud Achiever Series Multi position Gas Furnaces

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

INSTALLATION INSTRUCTIONS AND PARTS LIST TUBULAR GAS FIRED PROPELLER UNIT HEATERS

FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

GMS9/GCS9 SERIES 93% AFUE

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

80% A.F.U.E. DOWNFLOW GAS FURNACES

Thermal Efficiency Gas-Fired High Efficiency Unit Heater

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

True performance and rugged durability. TU, LF and LD Models

Installation, Operation, and Maintenance

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

FOR YOUR SAFETY. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

Modular Heating & Ventilating Unit Model IGX-HV

TECHNICAL SPECIFICATIONS

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Direct Fired Heater Model AD Specification

Ruud Achiever Plus Series Multi-position Gas Furnaces

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

Cabinet Unit Heaters Steam / Hot Water

Direct Gas-Fired Make-Up Air

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES

RGE 13 A T - 1 A

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

U n i t H e at e r s

MULTI POSITION GAS FURNACE

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

Ruud Acheiver Series Upflow Gas Furnaces

Transcription:

GTFC-7 HVAC HEATING PRODUCTS Application Manual SF/SC Series TF/TC Series GG Series TUBULAR GAS-FIRED UNIT HEATERS

Contents PAGE GENERAL INFORMATION All Series 2 GG SERIES Standard/Optional Features 3 Unit Number Description 3 Performance Data and Dimensional Data 4 Dimensional Data 5 TF/TC SERIES Standard/Optional Features 6 Unit Number Description 6 Performance and Dimensional Data TF Series 7 Performance and Dimensional Data TC Series 8 Performance Data TC Series 9 SF/SC SERIES Standard/Optional Features 0 Unit Number Description 0 Performance and Dimensional Data SF Series Performance and Dimensional Data SC Series 2 Performance Data SC Series 3 OPTIONAL ACCESSORIES All Series 4 HEAT THROW DATA All Series 5 NOZZLE DIMENSIONS 7 TYPICAL STANDARD SPECIFICATIONS GG Series 8 TF/TC Series 8 SF/SC Series 9 WARRANTY All Series 20 General Information STERLING TUBULAR DESIGN GAS FIRED UNIT HEATER The Sterling Tubular gas-fired unit heaters offer a highly efficient, extremely durable alternative to the traditional clam shell design. These units combine the latest tubular heat exchanger and inshot burner technology with the quality and reliability you have come to know from Sterling. HIGH EFFICIENCY Standard energy saving features like the direct spark ignition and power venting reduce standby losses and offer improved seasonal efficiencies. Tubular units certified by ETL as providing 83% thermal (combustion) efficiency. TUBULAR HEAT EXCHANGER The Sterling tubular heat exchanger has been designed to provide maximum and uniform heat transfer. The low pressure drop associated with this design enables heated air to be evenly distributed to the conditioned space. This curved, non-welded serpentine design experiences less thermally induced stress making it highly durable for significantly longer service life. All Sterling tubular heat exchangers are constructed of heavy duty 20-gauge aluminized steel. Optional 409 stainless steel heat exchangers are also available. DIRECT SPARK IGNITION SYSTEM Sterling Tubular units utilize a direct spark pilotless ignition of the burner, providing fast heat delivery. This highly reliable and efficient ignition system incorporates an integrated electronic control board to regulate the system sequence of operation, including an onboard LED indicator for simple troubleshooting. VENTING The Sterling Tubular unit heaters are ETL certified in accordance with categories I and III venting requirements. This certification allows units to be vented both vertically and horizontally using either single wall or double wall venting materials. This venting flexibility of the unit heater makes installation easier and more cost effective by allowing the installer to utilize existing venting components. CONTROL ACCESSIBILITY Designed with the service person in mind, every component of the Sterling unit heaters is easily accessible. Ignition and fan controls are located in one centrally located control panel. The access door provides control isolation as well as a pleasing exterior appearance. 0-YEAR WARRANTY Sterling warranties the heat exchanger, flue collector and burners of each unit heater to be free from defects in materials and workmanship for a period of 0 years from the date of manufacture. SEPARATED COMBUSTION - SF/SC SERIES The SF/SC series heater separates the combustion process from the environment where the unit is installed. A power venting system draws a controlled quantity of combustion air from outside the building. The same system exhausts flue products to the outside. The burners, pilot and flue system are enclosed within the unit; thus, the entire combustion process is unaffected by the atmosphere in the space where the heater is located. Separated combustion units are designed to be installed where dusty, dirty or mildly corrosive conditions exist or where high humidity or slightly negative pressure prevail. 2

GG Series Low Profile Unit Heater RESIDENTIAL AND COMMERCIAL CERTIFICATIONS The Sterling GG Series unit heater conforms with the latest ETL certification standards. Design certified under ANSI Z83.8 for Industrial/Commercial use and the more demanding requirements of CSA 0.96 USA (2nd ed.) Unit Heaters for Residential Installation, make this low profile unit heater the ideal selection. STANDARD FEATURES 82+% Thermal Efficiency Redundant Single-Stage Gas Valve Residential Certification 20/24V Control Transformer OSHA Fan Guard OPTIONAL FEATURES 409 Stainless Steel Heat Exchanger Two-Stage Gas Control (Sizes 60-20 Only) Stainless Steel Flue Collector Unit Number Description 5//60 Fan Motor with Internal Overload Protection Direct Spark Ignition 20-Gauge Cabinet with Baked Enamel Finish 0 Year Heat Exchanger Warranty Supply Voltage (Field Mounted Transformers): 208//60 230//60 208/3/60 230/3/60 460/3/60 575/3/60 Right Hand Control Access - Field Convertible to Left Hand High Limit Switch Air Pressure Switch Natural or Propane Gas Gas Conversion Kit Included Vent Caps Totally Enclosed Motors (Sizes 60-20 Only) Pressure Regulator ( 2 psi) Single & Two- Stage Mercury Free Thermostats Field Convertible to Separated Combustion Easy Access Control Panel 32 Stainless Steel Burner Box 20-Gauge Aluminized Heat Exchanger Power Vented Line Volt Thermostat Locking Thermostat Cover 24V SPST Relay Concentric Vent Kits (For All Separated Combustion Installations) Digit G X X X 2 3 4 5 6 7 8 9 0 2 3 4 5 + Item Prefix UT CA FT FM GT AL GC SV MT DL AS (Internal use Only), 2 - Unit Type [UT] GG - Residential Low Profile Tubular Propeller Note: Field conversion to Separated Combustion requires a Concentric Vent Kit. See Accessory Options X7-4 and X7-5 for proper unit selection. 3, 4, 5 - Capacity [CA] 030-30,000 BTU/HR 045-45,000 BTU/HR 060-60,000 BTU/HR 075-75,000 BTU/HR 090-90,000 BTU/HR 05-05,000 BTU/HR 20-20,000 BTU/HR 6 - Furnace Type [FT] A - Right Hand Access 7 - Furnace Material [FM]* - Standard (Aluminized) Steel 2-409 Stainless Steel *Heat exchanger tube material only. 8 - Gas Type [GT] N - Natural Gas P - Propane (LP) Gas 9 - Altitude [AL] P - Canadian High Altitude 2,000 4,500 ft. S - 0 4,999 ft. T - 5,000,999 ft. Note: Installations over 2,000 ft. require gas input deration in the field. Refer to unit installation instructions. 0 - Gas Control [GC] A - Single Stage (Standard) B - Two Stage (Capacities [CA] 060 through 20 only) - Supply Voltage [SV] - 5//60 5-230/3/60 2-208//60 6-460/3/60 3-230//60 7-575/3/60 4-208/3/60 Z - Other Note: Supply Voltage [SV] 2-7 include field mounted step down transformer. 2 - Motor Type [MT] - Open Drip Proof (Standard) 2 - Totally Enclosed (Capacities [CA] 060 through 20 only) 3 - Development Level [DL] C - Production Onset 4, 5+ - Accessories [AS] FACTORY INSTALLED S3 - Stainless Steel Flue Collector Z - Special All Accessories are to be entered as a separate line item using catalog number which places AS as a prefix. i.e: A7 becomes AS-A7. FIELD INSTALLED (AS- ) A7 - Pressure Regulator -2 psi G - -Stage T87K Mercury Free Thermostat w/subbase Kit G2 - -Stage T87K Mercury Free Thermostat w/tg5a Guard Kit G3 - -Stage T834N Mercury Free Thermostat/Fan Switch G5-2-Stage TH5220D Mercury Free Thermostat w/subbase G6 - Locking Thermostat Cover G8 - -Stage T669C Line Voltage Thermostat w/subbase G9 - -Stage T822K Mercury Free Thermostat P5-24V SPST Relay-Specify Purpose VC-4-4" Vent Cap X7-4 - Concentric Vent Kit (Capacities [CA] 030-075) X7-5 - Concentric Vent Kit (Capacities [CA] 090-20) 3

CM GG Series Low Profile Unit Heater Performance and Dimensional Data INTERTEK VERIFIED ENERGY PERFORMANCE VERIFIED RENDEMENT ENERGETIQUE VERIFIE UNIT CAPACITY (MBH) 30 45 60 75 90 05 20 PERFORMANCE DATA Input - BTU/Hr 30,000 45,000 60,000 75,000 90,000 05,000 20,000 (kw) (8.8) (3.2) (7.6) (22.0) (26.4) (30.8) (35.2) Output - BTU/Hr 24,900 37,350 49,800 6,500 73,800 86,00 98,400 (kw) (7.2) (0.9) (4.5) (8.0) (2.6) (25.2) (28.8) Thermal Efficiency - % 83 83 83 82 82 82 82 Free Air Delivery - CFM 370 550 740 920,00,300,475 (cu. m/s) (.75) (.260) (.349) (.434) (.59) (.64) (.696) Air Temperature Rise - F 60 60 60 60 60 60 60 ( C) (5) (5) (5) (5) (5) (5) (5) Full Load Amps at 20V 3.0 3.0 4. 4. 6.4 6.4 6.4 Maximum Circuit Ampacity 3.5 3.5 4.8 4.8 7.5 7.5 7.5 MOTOR DATA: Motor HP 0 0 /2 /2 /0 /0 /0 Motor (kw) (0.04) (0.04) (0.06) (0.06) (0.075) (0.075) (0.075) Motor Type SP SP SP SP SP SP SP RPM 650 650 050 050 050 050 050 Motor Amps @ 5V.9.9 2.6 2.6 4.2 4.2 4.2 DIMENSIONAL DATA - Inches (mm) A Jacket Height 2-3/8 2-3/8 5-7/8 5-7/8 22-5/8 22-5/8 22-5/8 (34) (34) (403) (403) (574) (574) (574) B Overall Height 3-/4 3-/4 6-3/6 6-3/6 23-9/6 23-9/6 23-9/6 (337) (337) (427) (427) (598) (598) (598) C Overall Depth 25-7/8 25-7/8 26-3/6 26-3/6 26-3/8 26-3/8 26-3/8 (632) (632) (665) (665) (670) (670) (670) D Center Line Height of Flue* 8-8- 0-3/8 0-3/8 3-5/8 3-5/8 3-5/8 (26) (26) (263) (263) (346) (346) (346) D2 Center Line Height of Air Intake 8-8- 8 8 8-5/8 8-5/8 8-5/8 (26) (26) (203) (203) (29) (29) (29) E Fan Diameter 0 0 4 4 6 6 6 (254) (254) (356) (356) (406) (406) (406) F Discharge Opening Height 0-3/6 0-3/6 4-7/6 4-7/6 2-3/6 2-3/6 2-3/6 (275) (275) (367) (367) (538) (538) (538) G Vent Connection Diameter 4 4 4 4 4 4 4 (02) (02) (02) (02) (02) (02) (02) H Center Line of Flue Connection From Side 7-/4 7-/4 7-/4 7-/4 7-7- 7- (84) (84) (84) (84) (97) (97) (97) H2 Center Line of Air Intake From Side 2-2- 2-2- 3-3- 3- (70) (70) (70) (70) (89) (89) (89) VENT SIZE REQUIREMENTS - STANDARD COMBUSTION Category III Horizontal - Inches (mm) 4 4 4 4 4 4 4 (02) (02) (02) (02) (02) (02) (02) Category I & III Vertical - Inches (mm) 4 4 4 4 4 4 4 (02) (02) (02) (02) (02) (02) (02) VENT SIZE REQUIRMENTS - SEPARATED COMBUSTION Exhaust Diameter** - Inches (mm) 4 4 4 4 5 5 5 (02) (02) (02) (02) (27) (27) (27) Intake Air Diameter - Inches (mm) 4 4 4 4 5 5 5 (02) (02) (02) (02) (27) (27) (27) Unit Weight - Lbs 60 65 80 85 95 05 0 (kgs) (27) (29) (36) (39) (43) (48) (50) Shipping Weight - Lbs 70 75 90 95 0 5 20 (kgs) (32) (34) (4) (43) (50) (52) (54) *For all installations, the flue collar is included with the unit and should be field installed per the instructions included with the unit. **4-5" reducer supplied where required. Ratings shown are for unit installations at elevations between 0 and 2,000 ft (0 to 60m). For unit installations in USA above 2,000 ft. (60m), the unit input must be derated 4% for each,000 ft. (305m) above sea level; refer to local codes, or in absence of local codes, refer to the latest edition of the National Fuel Gas Code, ANSI Standard Z223. (NFPA No. 54). For installations in Canada, any reference to deration at altitudes in excess of 2,000 ft. (60m) are to be ignored. At altitudes of 2,000 ft. to 4,500 ft. (60 to 372m), the unit must be derated to 90% of the normal altitude rating, and be so marked in accordance with the ETL certification. 4

GG Series Low Profile Unit Heater Dimensional Data DIMENSIONS.XXX STANDARD UNITS DIMENSIONS IN PARENTHESIS (XXX) MILLIMETERS 5

TF/TC Series Tubular Unit Heater STANDARD FEATURES In-Shot Burner Main Control Design Panel 20-Gauge Steel Jacket with Baked Enamel Finish 5//60 Supply Voltage Direct Spark Ignition OPTIONAL FEATURES Stainless Steel Supply Voltages: Heat Exchanger, 208 & 230//60 Burners and/or and 230, 460, Flue Collector 575/3/60 Redundant Single-Stage Gas Valve 5/24 Volt Control Transformer Premium Efficiency Blower Motors in ODP and TE Types Individually Adjustable and Removable Louvers Power Vented Two-Stage and Various Electronic Modulation Gas Controls 5//60 Volt Motor with Internal Overload Protection Discharge Nozzles (30, 60 & 90 ) or Duct Flange Assembly 0 Year Heat Exchanger, Flue Collector and Burner Warranty 82+% Thermal Efficiency Unit Number Description TF Series Digit T X X X 2 3 4 5 6 7 8 9 0 2 3 + Item Prefix UT CA FT FM GT AL GC SV MT AS (Internal use Only) TC Series Digit T X X X 2 3 4 5 6 7 8 9 0 2 3 4 + Item Prefix UT CA FT FM GT AL GC SV MT MS AS (Internal use Only), 2 - Unit Type [UT] TF - Tubular Propeller TC - Tubular Blower 3, 4, 5 - Capacity [CA] 00-00,000 BTU/HR 25-25,000 BTU/HR 50-50,000 BTU/HR 75-75,000 BTU/HR 200-200,000 BTU/HR 250-250,000 BTU/HR 300-300,000 BTU/HR 350-350,000 BTU/HR 400-400,000 BTU/HR 6 - Furnace Type [FT] A - Right Side Access 7 - Heat Exchanger Construction Material [FM] - Standard (Aluminized) Steel 2-409 Stainless Steel 8 - Gas Type [GT] N - Natural Gas P - Propane Gas (LP) 9 - Altitude [AL] P - Canadian High Altitude 2,000 4,500 ft. S - 0 4,999 ft. T - 5,000,999 ft. Note: Installations over 2,000 ft. require gas input deration in the field. Refer to unit installation instructions. 0 - Direct Spark Gas Control [GC] - Single Stage 2 - Two Stage 3 - Electronic Modulation w/room Sensing 4 - Electronic Modulation w/duct Sensing 5 - Electronic Modulation w/duct Sensing & Room Ovrd. Stat 6 - Electronic Modulation w/external 4-20 ma Input 7 - Electronic Modulation w/external 0-0 VDC Input - Supply Voltage [SV] - 5//60 5-230/3/60 2-208//60 6-460/3/60 3-230//60 7-575/3/60 4-208/3/60 Z - Special Note: Supply Voltages [SV] 2-7 include step down transformer. Field mounted for propeller units, factory mounted for blower units. 2 - Motor Type [MT] - Open Drip Proof (Standard) 2 - Totally Enclosed 3 - Premium Efficiency, Open Drip Proof (Blowers only) 4 - Premium Efficiency, Totally Enclosed (Blowers only) 3 - Blower Motor Sizes [MS]** A - /4 HP w/contactor L - HP C - HP w/contactor P - HP w/magnetic Starter D - HP w/contactor R - HP w/magnetic Starter F - HP w/contactor S - HP w/magnetic Starter G - - HP w/contactor T - - HP w/magnetic Starter H - 2 HP w/contactor U - 2 HP w/magnetic Starter J - /4 HP W - /4 HP w/magnetic Starter **Notes:. All 3-phase units [SV = 4, 5, 6, 7] include a contactor as standard. 2. All single phase units [SV =, 2, 3] include a contactor for units equipped with HP. motor or higher [MS =D, F, G, H] 3. [MS] options J, L only available with [SV] option (5//60). 3/4 - Accessories [AS] FACTORY INSTALLED M6 - OSHA Type Fan Guard (Propellers only) M8 - Discharge Duct Flange Assembly (Blowers only) P4 - Terminal Block Wiring P6 - Summer/Winter Switch S3-409 Stainless Steel Flue Collector S5-304L Stainless Steel Burners FIELD INSTALLED (AS- ) All Accessories are to be entered as a separate line item using catalog number which utilizes AS as a prefi x. i.e: A7 becomes AS-A7. A7 - Pressure Regulator -2 psi M2-2 - Vent Caps (5") (Unit Capacity 00-250) M2-3 - Vent Caps (6") (Unit Capacity 300-400) F - -Stage T675A Ductstat F2-2-Stage T678A Ductstat P5-24V SPST Relay-Specify Purpose G - -Stage T87K Mercury Free Thermostat w/subase Kit G2 - -Stage T87K Mercury Free Thermostat w/tg5a Guard Kit G3 - -Stage T834N Mercury Free Thermostat/Fan Switch G5-2-Stage TH5220D Mercury Free Thermostat w/subbase G6 - Locking Thermostat Cover G8 - -Stage T669C Line Voltage Stat w/subbase G9 - -Stage T822K Mercury Free Thermostat X2-30 Degree Downturn Nozzle X3-60 Degree Downturn Nozzle X4-90 Degree Downturn Nozzle X5 - Vertical Louver Kit 6

CM TF Series Tubular Propeller Unit Heater Performance and Dimensional Data INTERTEK VERIFIED ENERGY PERFORMANCE VERIFIED RENDEMENT ENERGETIQUE VERIFIE UNIT CAPACITY (MBH) 00 25 50 75 200 250 300 350 400 PERFORMANCE DATA Input - BTU/Hr 00,000 25,000 50,000 75,000 200,000 250,000 300,000 350,000 400,000 (kw) (29.3) (36.6) (43.9) (5.2) (58.6) (73.2) (87.8) (02.5) (7.) Output - BTU/Hr 83,000 03,750 24,500 45,250 66,000 207,500 249,000 290,500 332,000 (kw) (24.3) (30.4) (36.4) (42.5) (48.6) (60.7) (72.9) (85.) (97.2) Thermal Efficiency - % 83 83 83 83 83 83 83 83 83 Free Air Delivery - CFM,600 2,200 2,400 2,850 3,200 3,450 5,000 5,600 5,800 (cu. m/s) (0.756) (.039) (.33) (.346) (.5) (.629) (2.36) (2.644) (2.738) Air Temperature Rise - F 47 42 47 46 47 54 45 47 5 ( C) (26) (23) (26) (26) (26) (30) (24) (26) (28) Full Load Amps at 20V 5.3 5.8 5.8 8.0 8.0 8.0.3 3.5 3.5 MOTOR DATA: Motor HP (Qty.) /0 /4 /4 /3 /3 /3 (2) /4 (2) /3 (2) /3 Motor kw (0.080) (0.9) (0.9) (0.25) (0.25) (0.25) (0.9) (0.25) (0.25) Motor Type** SP PSC PSC PSC PSC PSC PSC PSC PSC RPM,50,40,40,40,40,40,40,40,40 Amps @ 5V 4.7 4.7 4.7 5.8 5.8 5.8 9.4.6.6 DIMENSIONAL DATA - Inches (mm) A Overall Height to Top of Flue 33-33- 33-33- 33-33- 34 34 34 (857) (857) (857) (857) (857) (857) (864) (864) (864) B Jacket Width of Unit 20-20- 20-32- 32-32- 50-50- 50- (527) (527) (527) (83) (83) (83) (289) (289) (289) C Width to CL Flue 3-3/8 3-3/8 3-3/8 9-3/8 9-3/8 9-3/8 28-3/8 28-3/8 28-3/8 (340) (340) (340) (492) (492) (492) (72) (72) (72) D Depth to Rear of Housing 2-/4 2-/4 2-/4 (279) (279) (279) (279) (279) (279) (3) (3) (3) E Hanging Distance Width 8-5/8 8-5/8 8-5/8 30-5/8 30-5/8 30-5/8 48-5/8 48-5/8 48-5/8 (473) (473) (473) (778) (778) (778) (235) (235) (235) F Discharge Opening Width 8-8- 8-30- 30-30- 48-48- 48- (476) (476) (476) (78) (78) (78) (238) (238) (238) G Depth to CL Flue 4-4- 4-4- 4-4- 5-/8 5-/8 5-/8 (2) (2) (2) (2) (2) (2) (30) (30) (30) H Discharge Opening Height 24-24- 24-24- 24-24- 24-24- 24- (622) (622) (622) (622) (622) (622) (622) (622) (622) L Overall Unit Width 25-/4 25-/4 25-/4 37-/4 37-/4 37-/4 55-/4 55-/4 55-/4 (64) (64) (64) (946) (946) (946) (403) (403) (403) *Vent Size Diameter - Inches 5 5 5 5 5 5 6 6 6 (mm) (27) (27) (27) (27) (27) (27) (52) (52) (52) Fan Diameter - Inches (Qty.) 6 6 6 8 8 8 (2) 6 (2) 8 (2) 8 Gas Inlet-Natural Gas (Inches) Gas Inlet- LP Gas (Inches) OR OR OR OR Approximate Unit Weight - Lbs 33 45 55 9 20 2 307 32 335 (kg) (60) (66) (70) (87) (9) (96) (39) (45) (52) Approximate Ship Weight - Lbs 73 85 95 24 25 26 367 38 395 (kg) (78) (84) (88) (09) (4) (8) (66) (73) (79) Ratings shown are for unit installations at elevations between 0 and 2,000 ft (0 to 60m). For unit installations in USA above 2,000 ft. (60m), the unit input must be derated 4% for each,000 ft. (305m) above sea level; refer to local codes, or in absence of local codes, refer to the latest edition of the National Fuel Gas Code, ANSI Standard Z223. (NFPA No. 54). For installations in Canada, any reference to deration at altitudes in excess of 2,000 ft. (60m) are to be ignored. At altitudes of 2,000 ft. to 4,500 ft. (60 to 372m), the unit must be derated to 90% of the normal altitude rating, and be so marked in accordance with the ETL certification. * Flue collar is factory supplied with unit; to be field installed per included instructions. ** LEGEND: SP = SHADED POLE PSC = PERMANENT SPLIT CAPACITOR -3/8" (35) (Hanging) C E (Hanging) Flue * D G -5/8" (295) (Hanging) 32-" (826) L B H (Discharge Opening) 33" A D467 DIMENSIONS.XXX STANDARD UNITS DIMENSIONS IN PARENTHESIS (XXX) MILLIMETERS D467 Electrical Control Panel Gas Valve F (Discharge Opening) Rear View Side View Front View " (25) 7

CM TC Series Tubular Blower Unit Heater Performance and Dimensional Data INTERTEK VERIFIED ENERGY PERFORMANCE VERIFIED RENDEMENT ENERGETIQUE VERIFIE UNIT CAPACITY (MBH) 00 25 50 75 200 250 300 350 400 PERFORMANCE DATA Input - BTU/Hr 00,000 25,000 50,000 75,000 200,000 250,000 300,000 350,000 400,000 (kw) (29.3) (36.6) (44.0) (5.3) (58.6) (73.3) (87.9) (02.6) (7.2) Output - BTU/Hr 83,000 03,750 24,500 45,250 66,000 207,500 246,000 290,500 332,000 (kw) (24.3) (30.4) (36.5) (42.6) (48.6) (60.8) (72.) (85.) (97.3) Thermal Efficiency - % 83 83 83 83 83 83 82 83 83 Free Air Delivery - CFM,8,476,77 2,067 2,362 2,953 3,50 4,34 4,724 (cu. m/s) (0.557) (0.697) (0.836) (0.976) (.5) (.394) (.652) (.95) (2.230) Air Temperature Rise - F 65 65 65 65 65 65 65 65 65 ( C) (36) (36) (36) (36) (36) (36) (36) (36) (36) Outlet Velocity - FPM 370 463 555 395.0 45.0 564.0 422 498 570 (m/s) (.879) (2.35) (2.89) (2.006) (2.29) (2.864) (2.43) (2.529) (2.895) Full Load Amps at 5V 7.4 0.5 0.5 3.8 3.8 5.2 4.4 9.9 9.9 Maximum Circuit Ampacity 8.7 2.6 2.6 7. 7. 8.7 8.4 24.7 24.7 MOTOR DATA Motor HP /4 - - Motor kw 0.9 0.37 0.37 0.56 0.56 0.75 0.75.. Motor Type** SPH SPH SPH SPH SPH Cap. Start Cap. Start Cap. Start Cap. Start RPM,725,725,725,725,725,725,725,725,725 Amps @ 5V 5.2 8.3 8.3.6.6 3.0 3.0 8.0 8.0 DIMENSIONAL DATA - Inches (mm) "A" Height to Top of Flue 33-33- 33-33- 33-33- 34 34 34 (857) (857) (857) (857) (857) (857) (864) (864) (864) "B" Jacket Width of Unit 20-20- 20-32- 32-32- 50-50- 50- (527) (527) (527) (832) (832) (832) (289) (289) (289) "C" Width to Centerline Flue 3-3/8 3-3/8 3-3/8 9-3/8 9-3/8 9-3/8 28-3/8 28-3/8 28-3/8 (340) (340) (340) (492) (492) (492) (72) (72) (72) "D" Depth to Front Hanger 2-/4 2-/4 2-/4 (279) (279) (279) (279) (279) (279) (3) (3) (3) "E" Hanging Distance Width 8-5/8 8-5/8 8-5/8 30-5/8 30-5/8 30-5/8 48-5/8 48-5/8 48-5/8 (473) (473) (473) (778) (778) (778) (235) (235) (235) "F" Hanging Distance Depth 2-25/32 22-/32 22-/32 25-/32 25-/32 25-/32 26-3/32 25-/32 25-/32 (553) (560) (560) (644) (644) (644) (663) (644) (644) "G" Discharge Opening Width 8-8- 8-30- 30-30- 48-48- 48- (476) (476) (476) (78) (78) (78) (238) (238) (238) "H" Depth to Centerline Flue 4-4- 4-4- 4-4- 5-/8 5-/8 5-/8 (2) (2) (2) (2) (2) (2) (30) (30) (30) "L" Discharge Opening Height 24-24- 24-24- 24-24- 24-24- 24- (622) (622) (622) (622) (622) (622) (622) (622) (622) "M" Overall Unit Width 25-/4 25-/4 25-/4 37-/4 37-/4 37-/4 55-/4 55-/4 55-/4 (64) (64) (64) (946) (946) (946) (403) (403) (403) "P" Overall Unit Depth 52-53-3/6 53-7/32 59-/6 59-/6 59-/6 56-7/6 59-/6 59-/6 (340) (35) (352) (56) (56) (56) (434) (56) (56) *Vent Size Diameter - Inches 5 5 5 5 5 5 6 6 6 (mm) (27) (27) (27) (27) (27) (27) (52) (52) (52) Blower Size - Inches (Qty) 9 0 0 2 2 2 0 (2) 2 (2) 2 (2) Gas Inlet, Natural Gas - Inches Gas Inlet, LP Gas - Inches OR OR OR OR Approximate Unit Weight - Lbs 7 75 202 245 264 289 370 390 429 (kg) (78) (79) (92) () (20) (3) (68) (77) (95) Approximate Ship Weight - Lbs 256 26 289 38 400 425 520 547 595 (kg) (6) (8) (3) (73) (8) (93) (236) (248) (270) Ratings shown are for unit installations at elevations between 0 and 2,000 ft (0 to 60m). For unit installations in USA above 2,000 ft. (60m), the unit input must be derated 4% for each,000 ft. (305m) above sea level; refer to local codes, or in absence of local codes, refer to the latest edition of the National Fuel Gas Code, ANSI Standard Z223. (NFPA No. 54). For installations in Canada, any reference to deration at altitudes in excess of 2,000 ft. (60m) are to be ignored. At altitudes of 2,000 ft. to 4,500 ft. (60 to 372m), the unit must be derated to 90% of the normal altitude rating, and be so marked in accordance with the ETL certification. * Flue collar is factory supplied with unit; to be field installed H per included instructions. /8 E 32 M ** LEGEND: SPH = SPLIT PHASE C CAP. START = CAPACITOR START F D B Flue 33 L (Discharge Opening) A 8 D893 Electrical Control Panel Gas Valve G (Discharge Opening) P Rear View Side View Front View

TC Series Tubular Blower Unit Heater Performance Data Unit TC00 TC25 TC50 TC75 TC200 TC250 TC300 TC350 TC400 Temp.Rise F ( C) CFM (cu. m/s) External Static Pressure Inches WP (kpa) 0." (0.02) 0.2" (0.05) 0.3" (0.07) 0.4" (0.0) 0.5" (0.2) RPM HP (kw) RPM HP (kw) RPM HP (kw) RPM HP (kw) RPM HP (kw) 804 860 927 989 045 50 535 (0) (0.724) (0.37) (0.37) (0.37) (0.37) (0.37) 60 279 /4 /4 /4 /4 /4 649 760 82 890 963 (5.5) (0.603) (0.9) (0.9) (0.9) (0.9) (0.9) 70 096 /4 /4 /4 /4 /4 633 700 779 858 920 (2.) (0.57) (0.9) (0.9) (0.9) (0.9) (0.9) 80 959 /4 /4 /4 /4 /4 59 665 733 80 869 (26.6) (0.452) (0.9) (0.9) (0.9) (0.9) (0.9) 50 99 703 758 80 863 98 (0) (0.905) (0.37) (0.37) (0.37) (0.37) (0.37) 60 599 608 685 74 790 843 (5.5) (0.754) (0.37) (0.37) (0.37) (0.37) (0.37) 70 37 558 626 694 755 798 (2.) (0.647) (0.37) (0.37) (0.37) (0.37) (0.37) 80 99 580 597 649 720 779 (26.6) (0.565) (0.37) (0.37) (0.37) (0.37) (0.37) 50 2303 853 927 962 988 040 (0) (.087) (0.37) (0.37) (0.37) (0.37) (0.37) 60 99 755 80 845 894 939 (5.5) (0.905) (0.37) (0.37) (0.37) (0.37) (0.37) 70 645 649 726 790 836 876 (2.) (0.776) (0.37) (0.37) (0.37) (0.37) (0.37) 80 439 66 670 720 785 840 (26.6) (0.679) (0.37) (0.37) (0.37) (0.37) (0.37) 50 2687 522 566 62 652 688 (0) (.26) (0.56) (0.56) (0.56) (0.56) (0.56) 60 2239 468 54 564 609 654 (5.5) (.05) (0.56) (0.56) (0.56) (0.56) (0.56) 70 99 423 47 527 582 624 (2.) (0.905) (0.56) (0.56) (0.56) (0.56) (0.56) 80 697 402 482 55 567 609 (26.6) (0.8) (0.56) (0.56) (0.56) (0.56) (0.56) 50 307 592 627 670 702 748 (0) (.44) (0.56) (0.56) (0.56) (0.56) (0.56) 60 2559 526 56 597 647 688 (5.5) (.2) (0.56) (0.56) (0.56) (0.56) (0.56) 70 293 468 59 556 62 653 (2.) (.03) (0.56) (0.56) (0.56) (0.56) (0.56) 80 99 432 48 537 593 638 (26.6) (0.905) (0.56) (0.56) (0.56) (0.56) (0.56) 50 3839 734 766 802 836 863 (0) (.8) (0.75) (0.75) (.) (.) (.) 60 399 626 668 700 749 780 (5.5) (.5) (0.75) (0.75) (0.75) (0.75) (0.75) 70 2742 545 593 633 680 78 (2.) (.29) (0.75) (0.75) (0.75) (0.75) (0.75) 80 2399 494 555 590 642 680 (26.6) (.3) (0.75) (0.75) (0.75) (0.75) (0.75) 50 455 734 766 802 836 863 (0) (2.4) (0.75) (0.75) (.) (.) (.) 60 3792 626 668 700 749 780 (5.5) (.79) (0.75) (0.75) (0.75) (0.75) (0.75) 70 3259 545 593 633 680 78 (2.) (.53) (0.75) (0.75) (0.75) (0.75) (0.75) 80 2844 494 555 590 642 680 (26.6) (.34) (0.75) (0.75) (0.75) (0.75) (0.75) 50 5374 558 598 638 676 727 (0) (2.54) (.) (.) (.) (.) (.) 60 4478 484 532 588 653 680 (5.5) (2.) (.) (.) (.) (.) (.) 70 3839 45 503 559 609 654 (2.) (.8) (.) (.) (.) (.) (.) 80 3359 408 480 536 589 62 (26.6) (.59) (.) (.) (.) (.) (.) 50 642 2 647 659 670 73 75 (0) (2.9) (.) (.) (.) (.) (.49) 60 58 553 570 68 653 697 (5.5) (2.4) (.) (.) (.) (.) (.) 70 4387 483 523 568 65 660 (2.) (2.07) (.) (.) (.) (.) (.) 80 3839 437 490 547 589 655 (26.6) (.8) (.) (.) (.) (.) (.) 9

SF/SC Series Separated Combustion Unit Heater STANDARD FEATURES Enclosed 5/24 Volt Combustion Control System Transformer 20-Gauge Aluminized Steel Tubular Heat Exchanger 83% Thermal Efficiency Combustion Air Pressure Switch OPTIONAL FEATURES Stainless Steel Supply Voltages: Heat Exchanger, 208 & 230//60 Burners, and/or and 208, 230, Flue Collector 460, 575/3/60 ODP Motor (with Overload Protection) Redundant Single-Stage Gas Valve Two-Stage and Various Electronic Modulation Gas Controls Unit Number Description 20-Gauge Steel Cabinetry with Baked Enamel Finish Direct Spark Ignition System 5//60 Supply Voltage Premium Efficiency Blower Motors in ODP & TE Types Digit T X X X 2 3 4 5 6 7 8 9 0 2 3 4 + Item Prefix UT CA FT FM GT AL GC SV MT MS AS (Internal use Only) Rear Burner Access Power Vented Individually Adjustable and Removable Horizontal Louvers Discharge Nozzles (30, 60 & 90 ) or Duct Flange Assembly Complete Belt /Fan Guard Main Control Panel 0 Year Heat Exchanger, Flue Collector and Burner Warranty Combustion Air Inlet Kits (allows concentric venting with horizontal or vertical termination), 2 - Unit Type [UT] SF - Separated Combustion Tubular Propeller SC - Separated Combustion Tubular Blower 3, 4, 5 - Capacity [CA] 00-00,000 BTU/HR 25-25,000 BTU/HR 50-50,000 BTU/HR 75-75,000 BTU/HR 200-200,000 BTU/HR 250-250,000 BTU/HR 300-300,000 BTU/HR 350-350,000 BTU/HR 400-400,000 BTU/HR 6 - Furnace Type [FT] A - Right Side Access 7 - Heat Exchanger Construction Material [FM] - Standard (Aluminized) Steel 2-409 Stainless Steel 8 - Gas Type [GT] N - Natural Gas P - Propane Gas (LP) 9 - Altitude [AL] P - Canadian High Altitude 2,000 4,500 ft. S - 0 4,999 ft. T - 5,000,999 ft. Note: Installations over 2,000 ft. require gas input deration in the field. Refer to unit installation instructions. 0 - Direct Spark Gas Control [GC] - Single Stage 2 - Two Stage 3 - Electronic Modulation w/room Sensing 4 - Electronic Modulation w/duct Sensing 5 - Electronic Modulation w/duct Sensing & Room Ovrd. Stat 6 - Electronic Modulation w/external 4-20 ma Input 7 - Electronic Modulation w/external 0-0 VDC Input - Supply Voltage [SV] - 5//60 5-230/3/60 2-208//60 6-460/3/60 3-230//60 7-575/3/60 4-208/3/60 Z - Special Note: Supply Voltages [SV] 2-7 include step down transformer. Field mounted for propeller units, factory mounted for blower units. 2 - Motor Type [MT] - Open Drip Proof (Standard) 2 - Totally Enclosed 3 - Premium Efficiency, Open Drip Proof (Blowers Only) 4 - Premium Efficiency, Totally Enclosed (Blowers Only) 3 - Blower Motor Sizes [MS]** A - /4 HP w/contactor P - HP w/magnetic Starter C - HP w/contactor R - HP w/magnetic Starter D - HP w/contactor S - HP w/magnetic Starter F - HP w/contactor T - - HP w/magnetic Starter G - - HP w/contactor U - 2 HP w/magnetic Starter H - 2 HP w/contactor W - /4 HP w/magnetic Starter J - /4 HP 0 - None/Not Applicable L - HP **Notes:. All 3-phase units [SV = 4, 5, 6, 7] include a contactor as standard. 2. All single phase units [SV =, 2, 3] include a contactor for units equipped with HP. motor or higher [MS =D, F, G, H] 3. [MS] options J, L only available with [SV] option (5//60). 4 - Accessories [AS] FACTORY INSTALLED M6 - OSHA Type Fan Guard (Propellers Only) M8 - Discharge Duct Flange (Blowers Only) P4 - Terminal Block Wiring P6 - Summer/Winter Switch S3-409 Stainless Steel Flue Collector S5-304L Stainless Steel Burners FIELD INSTALLED (AS- ) All Accessories are to be entered as a separate line item using catalog number which utilizes AS as a prefi x. i.e: A7 becomes AS-A7. A7 - Pressure Regulator -2 psi M2-2 - Vent Caps (5") (Unit Capacity 00-250) M2-3 - Vent Caps (6") (Unit Capacity 300-400) F - -Stage T675A Ductstat (Blowers Only) F2-2-Stage T678A Ductstat (Blowers Only) P5-24V SPST Relay-Specify Purpose G - -Stage T87K Mercury Free Thermostat X2-30 Degree Downturn Nozzle w/subase Kit X3-60 Degree Downturn Nozzle G2 - -Stage T87K Mercury Free Thermostat X4-90 Degree Downturn Nozzle w/tg5a Guard Kit X5 - Vertical Louver Kit G3 - -Stage T834N Mercury Free Thermostat/Fan Switch X7-H5 - Horiz. Combustion Air Inlet Kit, 5 inch G5-2-Stage TH5220D Mercury Free (Unit Capacity 00-250) Thermostat w/subbase X7-H6 - Horiz. Combustion Air Inlet Kit, 6 inch G6 - Locking Thermostat Cover (Unit Capacity 300-400) G8 - -Stage T669C Line Voltage Stat X7-V5 - Vert. Combustion Air Inlet Kit, 5 inch w/subbase (Unit Capacity 00-250) G9 - -Stage T822K Mercury Free X7-V6 - Vert. Combustion Air Inlet Kit, 6 inch Thermostat (Unit Capacity 300-400) 0

CM SF Series Separated Combustion Propeller Performance and Dimensional Data INTERTEK VERIFIED ENERGY PERFORMANCE VERIFIED RENDEMENT ENERGETIQUE VERIFIE UNIT CAPACITY (MBH) 00 25 50 75 200 250 300 350 400 PERFORMANCE DATA Input - BTU/Hr 00,000 25,000 50,000 75,000 200,000 250,000 300,000 350,000 400,000 (kw) (29.3) (36.6) (43.9) (5.2) (58.6) (73.2) (87.8) (02.5) (7.) Output - BTU/Hr 83,000 03,750 24,500 45,250 66,000 207,500 249,000 290,500 332,000 (kw) (24.3) (30.4) (36.4) (42.5) (48.6) (60.7) (72.9) (85.) (97.2) Thermal Efficiency - % 83 83 83 83 83 83 83 83 83 Free Air Delivery - CFM,600 2,200 2,400 2,850 3,200 3,450 5,000 5,600 5,800 (cu. m/s) (0.756) (.039) (.33) (.346) (.5) (.629) (2.36) (2.644) (2.738) Air Temperature Rise - F 47 42 47 46 47 54 45 47 5 ( C) (26) (23) (26) (26) (26) (30) (24) (26) (28) Full Load Amps at 20V 5.3 5.8 5.8 8.0 8.0 8.0.3 3.5 3.5 MOTOR DATA: Motor HP (Qty) /0 /4 /4 /3 /3 /3 /4 (2) /3 (2) /3 (2) Motor kw (0.080) (0.9) (0.9) (0.25) (0.25) (0.25) (0.9) (0.25) (0.25) Motor Type** SP PSC PSC PSC PSC PSC PSC PSC PSC RPM,050,40,40,40,40,40,40,40,40 Amps @ 5V 4.2 4.7 4.7 5.8 5.8 5.8 9.4.6.6 DIMENSIONAL DATA - Inches (mm) "A" Overall Height to Top of Flue 33-33- 33-33- 33-33- 34 34 34 (857) (857) (857) (857) (857) (857) (864) (864) (864) "B" Jacket Width of Unit 20-20- 20-32- 32-32- 50-50- 50- (527) (527) (527) (83) (83) (83) (289) (289) (289) "C" Width to CL Flue 3-3/8 3-3/8 3-3/8 9-3/8 9-3/8 9-3/8 28-3/8 28-3/8 28-3/8 (340) (340) (340) (492) (492) (492) (72) (72) (72) "D" Depth to Rear of Housing 2-/4 2-/4 2-/4 (279) (279) (279) (279) (279) (279) (3) (3) (3) "E" Hanging Distance Width 8-5/8 8-5/8 8-5/8 30-5/8 30-5/8 30-5/8 48-5/8 48-5/8 48-5/8 (473) (473) (473) (778) (778) (778) (235) (235) (235) "F" Discharge Opening Width 8-8- 8-30- 30-30- 48-48- 48- (476) (476) (476) (78) (78) (78) (238) (238) (238) "G" Depth to CL Flue 4-4- 4-4- 4-4- 5-/8 5-/8 5-/8 (2) (2) (2) (2) (2) (2) (30) (30) (30) "L" Overall Unit Width 25-/4 25-/4 25-/4 37-/4 37-/4 37-/4 55-/4 55-/4 55-/4 (64) (64) (64) (946) (946) (946) (403) (403) (403) *Vent Size Diameter - Inches 5 5 5 5 5 5 6 6 6 (mm) (27) (27) (27) (27) (27) (27) (52) (52) (52) Gas Inlet, Natural Gas - Inches Gas Inlet, LP Gas - Inches OR OR OR OR Approximate Unit Weight - Lbs 35 47 57 94 204 24 3 325 339 (kg) (6) (67) (7) (88) (93) (97) (4) (47) (54) Approximate Ship Weight - Lbs 75 87 97 244 254 264 37 385 399 (kg) (79) (85) (89) () (5) (20) (68) (75) (8) Ratings shown are for unit installations at elevations between 0 and 2,000 ft (0 to 60m). For unit installations in USA above 2,000 ft. (60m), the unit input must be derated 4% for each,000 ft. (305m) above sea level; refer to local codes, or in absence of local codes, refer to the latest edition of the National Fuel Gas Code, ANSI Standard Z223. (NFPA No. 54). For installations in Canada, any reference to deration at altitudes in excess of 2,000 ft. (60m) are to be ignored. At altitudes of 2,000 ft. to 4,500 ft. (60 to 372m), the unit must be derated to 90% of the normal altitude rating, and be so marked in accordance with the ETL certification. * Flue collar is factory supplied with unit; to be field installed per included instructions. ** LEGEND: SP = SHADED POLE PSC = PERMANENT SPLIT CAPACITOR -3/8' (35mm) (Hanging) E (Hanging) C Flue D G -5/8 (295mm) (Hanging) 32-' (826mm) L B 33" (838mm) 24- (622mm) (Discharge Opening) A D9067 Electrical Control Panel Gas Valve F (Discharge Opening) " (25mm) Rear View Side View Front View

CM SC Series Separated Combustion Blower Performance and Dimensional Data INTERTEK VERIFIED ENERGY PERFORMANCE VERIFIED RENDEMENT ENERGETIQUE VERIFIE UNIT CAPACITY (MBH) 00 25 50 75 200 250 300 350 400 PERFORMANCE DATA Input - BTU/Hr 00,000 25,000 50,000 75,000 200,000 250,000 300,000 350,000 400,000 (kw) (29.3) (36.6) (44.0) (5.3) (58.6) (73.3) (87.9) (02.6) (7.2) Output - BTU/Hr 83,000 03,750 24,500 45,250 66,000 207,500 246,000 290,500 332,000 (kw) (24.3) (30.4) (36.5) (42.6) (48.6) (60.8) (72.) (85.) (97.3) Thermal Efficiency - % 83 83 83 83 83 83 82 83 83 Free Air Delivery - CFM,8,476,77 2,067 2,362 2,953 3,50 4,34 4,724 (cu. m/s) (0.557) (0.697) (0.836) (0.976) (.5) (.394) (.652) (.95) (2.230) Air Temperature Rise - F 65 65 65 65 65 65 65 65 65 ( C) (36) (36) (36) (36) (36) (36) (36) (36) (36) Outlet Velocity - FPM 370 463 555 395.0 45.0 564.0 422 498 570 (m/s) (.879) (2.35) (2.89) (2.006) (2.29) (2.864) (2.43) (2.529) (2.895) Full Load Amps at 5V 7.4 0.5 0.5 3.8 3.8 5.2 4.4 9.9 9.9 Maximum Circuit Ampacity 8.7 2.6 2.6 7. 7. 8.7 8.4 24.7 24.7 MOTOR DATA: Motor HP /4 - - Motor kw 0.9 0.37 0.37 0.56 0.56 0.75 0.75.. Motor Type** SPH SPH SPH SPH SPH Cap. Start Cap. Start Cap. Start Cap. Start RPM,725,725,725,725,725,725,725,725,725 Amps @ 5V 5.2 8.3 8.3.6.6 3.0 3.0 8.0 8.0 DIMENSIONAL DATA - Inches (mm) "A" Height to Top of Flue 33-33- 33-33- 33-33- 34 34 34 (857) (857) (857) (857) (857) (857) (864) (864) (864) "B" Jacket Width of Unit 20-20- 20-32- 32-32- 50-50- 50- (527) (527) (527) (832) (832) (832) (289) (289) (289) "C" Width to Centerline Flue 3-3/8 3-3/8 3-3/8 9-3/8 9-3/8 9-3/8 28-3/8 28-3/8 28-3/8 (340) (340) (340) (492) (492) (492) (72) (72) (72) "D" Depth to Front Hanger 2-/4 2-/4 2-/4 (279) (279) (279) (279) (279) (279) (3) (3) (3) "E" Hanging Distance Width 8-5/8 8-5/8 8-5/8 30-5/8 30-5/8 30-5/8 48-5/8 48-5/8 48-5/8 (473) (473) (473) (778) (778) (778) (235) (235) (235) "F" Hanging Distance Depth 2-25/32 22-/32 22-/32 25-/32 25-/32 25-/32 26-3/32 25-/32 25-/32 (553) (560) (560) (644) (644) (644) (663) (644) (644) "G" Discharge Opening Width 8-8- 8-30- 30-30- 48-48- 48- (476) (476) (476) (78) (78) (78) (238) (238) (238) "H" Depth to Centerline Flue 4-4- 4-4- 4-4- 5-/8 5-/8 5-/8 (2) (2) (2) (2) (2) (2) (30) (30) (30) "M" Overall Unit Width 25-/4 25-/4 25-/4 37-/4 37-/4 37-/4 55-/4 55-/4 55-/4 (64) (64) (64) (946) (946) (946) (403) (403) (403) "P" Overall Unit Depth 52-53-3/6 53-7/32 59-/6 59-/6 59-/6 56-7/6 59-/6 59-/6 (340) (35) (352) (56) (56) (56) (434) (56) (56) *Vent Size Diameter - Inches 5 5 5 5 5 5 6 6 6 (mm) (27) (27) (27) (27) (27) (27) (52) (52) (52) Gas Inlet, Natural Gas - Inches Gas Inlet, LP Gas - Inches OR OR OR OR Approximate Unit Weight - Lbs 73 77 204 248 267 292 374 394 433 (kg) (78) (80) (92) (2) (2) (32) (70) (79) (96) Approximate Ship Weight - Lbs 258 263 29 384 403 428 524 55 599 (kg) (7) (9) (32) (74) (83) (94) (238) (250) (272) Ratings shown are for unit installations at elevations between 0 and 2,000 ft (0 to 60m). For unit installations in USA above 2,000 ft. (60m), the unit input must be derated 4% for each,000 ft. (305m) above sea level; refer to local codes, or in absence of local codes, refer to the latest edition of the National Fuel Gas Code, ANSI Standard Z223. (NFPA No. 54). For installations in Canada, any reference to deration at altitudes in excess of 2,000 ft. (60m) are to be ignored. At altitudes of 2,000 ft. to 4,500 ft. (60 to 372m), the unit must be derated to 90% of the normal altitude rating, and be so marked in accordance with the ETL certification. * Flue collar is factory supplied with unit; to be field installed per included instructions. ** LEGEND: SPH = SPLIT PHASE CAP. START = CAPACITOR START /8 (29mm) C E Flue F H 32 (826mm) D M B 33 (838mm) 24 (622mm) (Discharge Opening) A Electrical Control Panel Gas Valve P G (Discharge Opening) 2 Rear View Side View Front View D9050

SC Series Separated Combustion Blower Performance Data Unit SC00 SC25 SC50 SC75 SC200 SC250 SC300 SC350 SC400 Temp.Rise F ( C) CFM (cu. m/s) External Static Pressure Inches WP (kpa) 0." (0.02) 0.2" (0.05) 0.3" (0.07) 0.4" (0.0) 0.5" (0.2) RPM HP (kw) RPM HP (kw) RPM HP (kw) RPM HP (kw) RPM HP (kw) 804 860 927 989 045 50 535 (0) (0.724) (0.37) (0.37) (0.37) (0.37) (0.37) 60 279 /4 /4 /4 /4 /4 649 760 82 890 963 (5.5) (0.603) (0.9) (0.9) (0.9) (0.9) (0.9) 70 096 /4 /4 /4 /4 /4 633 700 779 858 920 (2.) (0.57) (0.9) (0.9) (0.9) (0.9) (0.9) 80 959 /4 /4 /4 /4 /4 59 665 733 80 869 (26.6) (0.452) (0.9) (0.9) (0.9) (0.9) (0.9) 50 99 703 758 80 863 98 (0) (0.905) (0.37) (0.37) (0.37) (0.37) (0.37) 60 599 608 685 74 790 843 (5.5) (0.754) (0.37) (0.37) (0.37) (0.37) (0.37) 70 37 558 626 694 755 798 (2.) (0.647) (0.37) (0.37) (0.37) (0.37) (0.37) 80 99 580 597 649 720 779 (26.6) (0.565) (0.37) (0.37) (0.37) (0.37) (0.37) 50 2303 853 927 962 988 040 (0) (.087) (0.37) (0.37) (0.37) (0.37) (0.37) 60 99 755 80 845 894 939 (5.5) (0.905) (0.37) (0.37) (0.37) (0.37) (0.37) 70 645 649 726 790 836 876 (2.) (0.776) (0.37) (0.37) (0.37) (0.37) (0.37) 80 439 66 670 720 785 840 (26.6) (0.679) (0.37) (0.37) (0.37) (0.37) (0.37) 50 2687 522 566 62 652 688 (0) (.26) (0.56) (0.56) (0.56) (0.56) (0.56) 60 2239 468 54 564 609 654 (5.5) (.05) (0.56) (0.56) (0.56) (0.56) (0.56) 70 99 423 47 527 582 624 (2.) (0.905) (0.56) (0.56) (0.56) (0.56) (0.56) 80 697 402 482 55 567 609 (26.6) (0.8) (0.56) (0.56) (0.56) (0.56) (0.56) 50 307 592 627 670 702 748 (0) (.44) (0.56) (0.56) (0.56) (0.56) (0.56) 60 2559 526 56 597 647 688 (5.5) (.2) (0.56) (0.56) (0.56) (0.56) (0.56) 70 293 468 59 556 62 653 (2.) (.03) (0.56) (0.56) (0.56) (0.56) (0.56) 80 99 432 48 537 593 638 (26.6) (0.905) (0.56) (0.56) (0.56) (0.56) (0.56) 50 3839 734 766 802 836 863 (0) (.8) (0.75) (0.75) (.) (.) (.) 60 399 626 668 700 749 780 (5.5) (.5) (0.75) (0.75) (0.75) (0.75) (0.75) 70 2742 545 593 633 680 78 (2.) (.29) (0.75) (0.75) (0.75) (0.75) (0.75) 80 2399 494 555 590 642 680 (26.6) (.3) (0.75) (0.75) (0.75) (0.75) (0.75) 50 455 734 766 802 836 863 (0) (2.4) (0.75) (0.75) (.) (.) (.) 60 3792 626 668 700 749 780 (5.5) (.79) (0.75) (0.75) (0.75) (0.75) (0.75) 70 3259 545 593 633 680 78 (2.) (.53) (0.75) (0.75) (0.75) (0.75) (0.75) 80 2844 494 555 590 642 680 (26.6) (.34) (0.75) (0.75) (0.75) (0.75) (0.75) 50 5374 558 598 638 676 727 (0) (2.54) (.) (.) (.) (.) (.) 60 4478 484 532 588 653 680 (5.5) (2.) (.) (.) (.) (.) (.) 70 3839 45 503 559 609 654 (2.) (.8) (.) (.) (.) (.) (.) 80 3359 408 480 536 589 62 (26.6) (.59) (.) (.) (.) (.) (.) 50 642 2 647 659 670 73 75 (0) (2.9) (.) (.) (.) (.) (.49) 60 58 553 570 68 653 697 (5.5) (2.4) (.) (.) (.) (.) (.) 70 4387 483 523 568 65 660 (2.) (2.07) (.) (.) (.) (.) (.) 80 3839 437 490 547 589 655 (26.6) (.8) (.) (.) (.) (.) (.) 3

Accessories [AC] FACTORY INSTALLED M6 - OSHA TYPE FAN GUARD Series TF, SF Factory installed available on series TF and SF only, standard on series GG. Required for installations that must conform to OSHA standards. Also known as fingerproof fan guards. M8 - DISCHARGE DUCT FLANGE ASSEMBLY Series TC, SC Factory Installed (Specify No Charge) Used in lieu of louvers on blower units for incorporating field duct work. P4 - TERMINAL BLOCK WIRING Series TF, TC, SF, SC Factory Installed Provides specific terminal designation for field wiring. P6 - SUMMER/WINTER SWITCH Series TF, TC, SF, SC Factory Installed Allows operation of fan or blower for ventilating purposes during hot summer months (manually operated). S3 - STAINLESS STEEL FLUE COLLECTOR Factory Installed 409 Stainless steel flue collector in lieu of standard aluminized steel collector. S5 - STAINLESS STEEL BURNERS Series TF, TC, SF, SC Factory Installed 304L Stainless steel in-shot burners in lieu of the standard aluminized steel in-shot burners. FIELD INSTALLED A7 - PRESSURE REGULATOR -2 PSI All Series & Sizes Required where main line pressure exceeds 4" WC ( psig), must specify incoming pressure when ordered. One regulator per unit required, shipped separately. F - ONE STAGE DUCTSTAT Series TC, SC Single pole, double throw. 55-75 F setpoint range. [2" W x 5-5/8" H x 2-7/6" D] F2 - TWO STAGE DUCTSTAT Series TC, SC Single pole, double throw. 55-75 F setpoint range. [2" W x 5-5/8" H x 2-7/6" D] G - ONE STAGE T87K (MERCURY-FREE) THERMOSTAT WITH SUBBASE Single stage heating thermostat with subbase. Includes fan switching relay. Standard round styling suitable for any decor. 40-90 F range. G2 - ONE STAGE T87K (MERCURY-FREE) THERMOSTAT WITH TG5A GUARD Same features as G except a tamper proof guard is included. G3 - ONE STAGE T834N (MERCURY-FREE) THERMOSTAT WITH FAN SWITCH Single stage heating thermostat with fan switch. Manufactured exclusively for Sterling with a Sterling logo face plate. 50-90 F range. [2-3/8" W x 4-" H x -" D] G5 - TWO STAGE TH5220D (MERCURY-FREE) THERMOSTAT WITH SUBBASE Two stage heating and two stage cooling with system and fan switching and built in 0 F heating/cooling differential. Includes fan relay. Heating 40-90 F range, Cooling 50-99 F. [5-3/6" W x 3-9/6" H x -" D] G6 - LOCKING THERMOSTAT COVER Universal locking thermostat cover for use with all thermostats listed. G8 - ONE STAGE T669C LINE VOLTAGE STAT WITH SUBBASE Single stage heating only thermostat. 5 volt operation. 44-86 F range [4-" W x 4-5/8" H x -7/8" D] G9 - ONE STAGE T822K (MERCURY-FREE) THERMOSTAT Single stage heating only thermostat with subbase. 24 volt operation. 50-90 F range. [2-7/8" W x 4-" H x -" D] M2-2, 3 - VENT CAP Series TF, TC, SF, SC 5 or 6 inch vent cap for use with series TF, TC, SF, SC. Must indicate unit size when ordered. P5-24 VOLT RELAY Specify purpose. 24 volt SPST relay. VC - 4 VENT CAP Series GG 4" vent cap for use with series GG. X2-30 NOZZLE Directs the discharge air at a 30 angle. Air can be directed up to 60 by adjusting the horizontal louvers. Louvers are supplied with the unit heater and must be reinstalled in the nozzle discharge. Must indicate unit size when ordered. X3-60 NOZZLE Directs the discharge air at a 60 angle. Air can be directed up to 90 by adjusting the horizontal louvers. Louvers are supplied with the unit heater and must be reinstalled in the nozzle discharge. Must indicate unit size when ordered. X4-90 NOZZLE Directs the discharge air at a 90 angle. Louvers are supplied with the unit heater and must be reinstalled in the nozzle discharge. Must indicate unit size when ordered. X5 - VERTICAL LOUVER KIT Series TF, TC, SF, SC Vertical Louvers to provide 4 way air deflection. Must indicate unit size when ordered. X7-4, 5 CONCENTRIC VENT KIT Series GG Allows for one 6 or 8" vent/combustion air opening through a structure. One kit permits for either horizontal or vertical applications. Kit required for converting a series GG to separated combustion. X7 - H5, H6 HORIZONTAL COMBUSTION AIR INLET KIT Series SF, SC Allows for one 8 or 0" horizontal vent/ combustion air opening through a structure. Must indicate unit size when ordered. X7 - V5, V6 VERTICAL COMBUSTION AIR INLET KIT Series SF, SC Allows for one 8 or 0" vertical vent/ combustion air opening through a structure. Must indicate unit size when ordered. 4

Heat Throw Data NOTES:. All throw data figures are approximations. Allowances should be made for optimum performance, altitude, etc. 2. NR - Units not recommended at these mounting heights. 3. 30, 60 and 90 nozzles are shipped unassembled. STANDARD UNIT HEATER APPLICATIONS 30 NOZZLE Distance From Floor to Bottom of Unit H Approximate Distance of Heat Throw - Feet (Meters) Ft. 30,000 45,000 60,000 75,000 (m) (8.8) (3.2) (7.6) (22.0) 8 33 33 33 40 (2.4) (0.) (0.) (0.) (2.2) 0 28 28 28 35 (3.0) (8.5) (8.5) (8.5) (0.7) 2 (3.7) NR NR NR NR 5 (4.6) NR NR NR NR 20 (6.) NR NR NR NR 90,000 00,000 05,000 20,000 (26.4) (29.3) (30.8) (34.2) 8 40 60 60 65 (2.4) (2.2) (8.3) (8.3) (9.8) 0 35 54 54 56 (3.0) (0.7) (6.5) (6.5) (7.) 2 44 44 46 NR (3.7) (3.4) (3.4) (4.0) 5 (4.6) NR NR NR NR 20 (6.) NR NR NR NR 25,000 50,000 75,000 200,000 (36.6) (43.9) (5.2) (58.6) 8 65 70 75 80 (2.4) (9.8) (2.3) (22.9) (24.4) 0 56 60 64 68 (3.0) (7.) (8.3) (9.5) (20.7) 2 46 49 57 6 (3.7) (4.0) (4.9) (7.4) (8.6) 5 45 49 52 NR (4.6) (3.7) (4.9) (5.8) 20 46 NR NR NR (6.) (4.0) 250,000 300,000 350,000 400,000 (73.2) (87.8) (02.5) (7.) 8 90 05 0 20 (2.4) (27.4) (32.0) (33.5) (36.6) 0 78 90 95 00 (3.0) (23.8) (27.4) (29.0) (30.5) 2 68 80 84 90 (3.7) (20.7) (24.4) (25.6) (27.4) 5 60 70 74 80 (4.6) (8.3) (2.3) (22.6) (24.4) 20 54 63 66 70 (6.) (6.5) (9.2) (20.) (2.3) Distance From Floor to Bottom of Unit H Ft. (m) 8 (2.4) 0 (3.0) 2 (3.7) 5 (4.6) 20 (6.) Approximate Distance of Heat Throw - Feet (Meters) 30,000 45,000 60,000 75,000 (8.8) (3.2) (7.6) (22.0) Data Not Available Data Not Available Data Not Available Data Not Available Data Not Available 90,000 00,000 05,000 20,000 (26.4) (29.3) (30.8) (34.2) 8 Data Not 65 Data Not Data Not (2.4) Available (9.8) Available Available 0 Data Not 57 Data Not Data Not (3.0) Available (7.4) Available Available 2 Data Not 50 Data Not Data Not (3.7) Available (5.2) Available Available 5 Data Not Data Not Data Not NR (4.6) Available Available Available 20 Data Not Data Not Data Not NR (6.) Available Available Available 25,000 50,000 75,000 200,000 (36.6) (43.9) (5.2) (58.6) 8 70 75 80 85 (2.4) (2.3) (22.9) (24.4) (25.9) 0 60 64 68 72 (3.0) (8.3) (9.5) (20.7) (2.9) 2 54 57 60 64 (3.7) (6.5) (7.4) (8.3) (9.5) 5 45 48 50 53 (4.6) (3.7) (4.6) (5.2) (6.2) 20 44 47 NR NR (6.) (3.4) (4.3) 250,000 300,000 350,000 400,000 (73.2) (87.8) (02.5) (7.) 8 95 5 20 25 (2.4) (29.0) (35.) (36.6) (38.) 0 86 99 05 0 (3.0) (26.2) (30.2) (32.0) (33.5) 2 77 88 94 00 (3.7) (23.5) (26.8) (28.7) (30.5) 5 64 74 79 84 (4.6) (9.5) (22.6) (24.) (25.6) 20 58 66 7 75 (6.) (7.7) (20.) (2.6) (22.9) 5

Heat Throw Data Distance From Floor to Bottom of Unit H Ft. (m) 8 (2.4) 0 (3.0) 2 (3.7) 5 (4.6) 20 (6.) 60 NOZZLE Approximate Distance of Heat Throw (Feet) Approximate Distance of Heat Throw - Feet (Meters) 30,000 45,000 60,000 75,000 (8.8) (3.2) (7.6) (22.0) Data Not Available Data Not Available Data Not Available Data Not Available Data Not Available 90,000 00,000 05,000 20,000 (26.4) (29.3) (30.8) (34.2) 8 Data Not 75 Data Not Data Not (2.4) Available (22.9) Available Available 0 Data Not 65 Data Not Data Not (3.0) Available (9.8) Available Available 2 Data Not 60 Data Not Data Not (3.7) Available (8.3) Available Available 5 Data Not 50 Data Not Data Not (4.6) Available (5.2) Available Available 20 Data Not Data Not Data Not NR (6.) Available Available Available 25,000 50,000 75,000 200,000 (36.6) (43.9) (5.2) (58.6) 8 80 85 90 95 (2.4) (24.4) (25.9) (27.4) (29.0) 0 70 75 79 83 (3.0) (2.3) (22.9) (24.) (25.3) 2 64 68 72 76 (3.7) (9.5) (20.7) (2.9) (23.2) 5 54 56 6 65 (4.6) (6.5) (7.) (8.6) (9.8) 20 49 52 55 59 (6.) (4.9) (5.8) (6.8) (8.0) 250,000 300,000 350,000 400,000 (73.2) (87.8) (02.5) (7.) 8 0 25 30 38 (2.4) (33.5) (38.) (39.6) (42.) 0 95 09 5 20 (3.0) (29.0) (33.2) (35.) (36.6) 2 84 00 03 08 (3.7) (25.6) (30.5) (3.4) (32.9) 5 7 85 88 94 (4.6) (2.6) (25.9) (26.8) (28.7) 20 65 77 8 85 (6.) (9.8) (23.5) (24.7) (25.9) Distance From Floor to Bottom of Unit H Ft. (m) 0 90 NOZZLE* Approximate Distance of Heat Throw - Feet (Meters) 00,000 25,000 50,000 (29.3) (36.6) (43.9) NR NR NR (3.0) 5 30 25 35 30 40 35 (4.6) (9.) x (7.6) (0.7) x (9.) (2.2) x (0.7) 20 (6.) NR NR NR 25 (7.6) NR NR NR 30 (9.) NR NR NR 75,000 200,000 250,000 (5.2) (58.6) (73.2) 0 (3.0) NR NR NR 5 45 40 50 40 60 45 (4.6) (3.7) x (2.2) (5.2) x (2.2) (8.3) x (3.7) 20 40 35 56 40 NR (6.) (2.2) x (0.7) (7.) x (2.2) 25 50 35 NR NR (7.6) (5.2) x (0.7) 30 (9.) NR NR NR 300,000 350,000 400,000 (87.8) (02.5) (7.) 0 NR NR NR (3.0) 5 70 45 80 50 00 50 (4.6) (2.3) x (3.7) (24.4) x (5.2) (30.5) x (5.2) 20 65 40 70 45 80 45 (6.) (9.8) x (2.2) (2.3) x (3.7) (24.4) x (3.7) 25 60 35 65 40 75 40 (7.6) (8.3) x (0.7) (9.8) x (2.2) (22.9) x (2.2) 30 55 35 60 35 65 40 (9.) (6.8) x (0.7) (8.3) x (0.7) (9.8) x (2.2) *It is not recommended to mount a unit with a 90 nozzle at 0 feet or less. Heat Throw data for GG Series units with a 90 nozzle installed is not currently available. 6

Nozzle Dimensions* A C A C B D B 30 NOZZLE 60 NOZZLE A C D B 90 NOZZLE *Nozzles are field assembled. NOZZLE DIMENSIONAL DATA CHART DIMENSION NOZZLE TYPE 30, 45 60, 75 90, 05, 20 00, 25, 50 75, 200, 250 300, 350, 400 9-5/8 9-5/8 9-5/8 20-32- 50-30 WIDTH (498) (498) (498) (527) (832) (289) A 9-5/8 9-5/8 9-5/8 20-32- 50-60 In. (498) (498) (498) (527) (832) (289) (mm) 9-5/8 9-5/8 9-5/8 20-32- 50-90 (498) (498) (498) (527) (832) (289) 2-/6 5-5/8 22-3/8 3-3- 3-30 HEIGHT (306) (397) (568) (800) (800) (800) B 2-/6 5-5/8 22-3/8 3-3- 3-60 In. (306) (397) (568) (800) (800) (800) (mm) 2-/6 5-5/8 22-3/8 3-3- 3-90 (306) (397) (568) (800) (800) (800) 3-/8 3-/8 3-/8 5 5 5 FURTHEST 30 (333) (333) (333) (38) (38) (38) DEPTH 22-3/6 22-3/6 22-3/6 25-25- 25- C 60 (564) (564) (564) (648) (648) (648) In. (mm) 25-9/6 25-9/6 25-9/6 28-/4 28-/4 28-/4 90 (694) (694) (694) (78) (78) (78) HEIGHT WITH OVERHANG D In. (mm) 30 N/A 60 90 3-5/6 6-7/8 23-5/8 30 30 30 (338) (429) (600) (762) (762) (762) 5-/4 8-3/6 25-9/6 34 34 34 (387) (478) (649) (864) (864) (864) 7