HERCULES (110V) (220V) USER S MANUAL

Similar documents
ELITE (110V) (220V)

CONSTANT SUCTION UNIT

Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution

MODEL 7000 SUCTION UNIT

BIOVAC 500 SMOKE EVACUATOR

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

OWNER S MANUAL FOR ASPIRATION / FILTRATION VACUUM SYSTEM MODELS: 2511 & 2515

High Output Vacuum/Pressure Pump

ADVANTAGE-100H-SC EXTRACTOR

OWNERS' GUIDE PRECISION WATER SYSTEMS WATER DISTILLER. Water Systems FOR MODELS: PWS MANUFACTURED BY:

ASPIRE Laboratory Aspirator

Refrigerant Recovery Machine. Model No Operating Manual

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

T-Series Air Conditioner T53 Model

T-Series Air Conditioner T15 Model

T-Series Air Conditioner T20 Model

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

Short Instruction for Use for in-home care ASSKEA procuff M and ASSKEA procuff S

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

HP310-C EXTRACTOR 120V

TERMINATOR 120V CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

MIRAI EXTRACTOR 100V DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

Instruction Cum User Manual For EUROLITE

Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System

R100 Oil-Less Refrigerant Recovery Unit

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

Safety, Operation and Maintenance Manual with Parts List

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-12 Task Force Pneumatic Portable Dental System

MJ190-4 Aspirator Operator s Manual

High Performance Oilless Residential Light Commercial. Product Leadership Training Service Reliability

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

Mobile Milker. Filling the oil reservoir to HALF FULL

Contents. Getting Started. Operation. Maintenance and Care. Problem Solving Guide. Warranty 13

USER MANUAL UN-200V / UN-200VH

CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

This symbol indicates an insulation class I device. This Symbol indicates a type B applied part. This symbol indicates alternate current

Owner s Manual Window Air Conditioner

PRO 2000i LOW LEVEL DEPOSITOR

PowerVac G Single to Twin Conversion Kit [ ]

EXTRACTOR Operation & Maintenance Manual

COBRA -H EXTRACTOR 120V

Technical Datasheet. Suction Controllers, Flow Meters & Accessories

Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

Thermo Scientific Air Cadet

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

(The chances are you re never going to read me) Owner s Manual HEAVY DUTY SHD-1T.

COBRA -300H EXTRACTOR

HHP-300 EXTRACTOR 120V

Nilfisk Inc Winnetka Avenue North Minneapolis, MN REV.03( ) VF80189

OWNER S MANUAL FOR ASPIRATION / FILTRATION VACUUM SYSTEM MODEL: 2511

SERRES SUCTION BAG SYSTEM MANUAL

MRS-6 Maxi-Guard II. Model: C , 12, 13, 14 OPERATION SERVICE PARTS CARE. Revised 2/02

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

SOLUS-500 EXTRACTOR 120V

R20SC, R20E & R20ENT. Owner s Manual

TABLE OF CONTENTS INSTRUCTIONS FOR USE OF CENTRI-MATIC III 286P-UL IMPORTANT INSTRUCTIONS FOR USE OF CENTRI-MATIC III 286P-UL LIMITED WARRANTY

Xaact Spot. Xaact Hot Spot

Owner s Manual for the Cordless Backpack

120V CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

The Professional Choice

12" Commercial Vacuum Sealer INSTRUCTIONS

PACER 30 VACUUM IMPORTANT SAFETY INSTRUCTIONS READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE OPERATING OR SERVICING MACHINE

DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

BEFORE OPERATING THE MACHINE: WARNING

OPERATOR S MANUAL & PARTS LIST

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

Suction unit Victoria

TRS21 IGNITION PROOF SERIES

A2Z Ozone, Inc. PRODUCT MANUAL

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS 2016, 2024, and 8111

OPERATION & MAINTENANCE MANUAL RHS680

KEEP FOR FUTURE REFERENCE 1 SCFM NOMINAL AIRFLOW SINGLE VACUUM SYSTEM DC-VOLTAGE POWER SYSTEM WITH MANUAL VALVE

USER MANUAL UR700QVAC and UR700QVAC-H

457LAVEXDM15 DUAL MOTOR HEPA UPRIGHT VACUUM CLEANER

D14 & D18 Upright Vacuum

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

SOLUS-310 EXTRACTOR 120V

Reliability is a beautiful thing TM CUBELET ICE DISPENSER DCM-500BAF DCM-500BWF DCM-750BAF DCM-750BWF INSTRUCTION MANUAL

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

Steele Extrusion Machinery

CHEST FREEZER INSTRUCTION MANUAL. Model No.: EWCF5WBX EWCF7WBX

TRS21 IGNITION PROOF SERIES

SECTION STEAM CONDENSATE PUMPS

690 and Power Fishing Systems

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

installation and operation manual for Hunter Ceiling Fans

OPERATING MANUAL AUTOMATIC SPRAY GUN CLEANERS UG7500 SERIES UNI-RAM CORPORATION ONTARIO CANADA PATENTS

Description of the vacuum. (The chances are you re never going to read me) Owner s Manual. models X9 & G9.

MODEL MC-UL592 MC-UL594 POWER SOURCE. 230V - 240V ~ 50 Hz MAX INPUT 1400 W 1500 W NOMINAL INPUT DIMENSIONS (W x L x H)

Transcription:

USER S MANUAL HERCULES 20-5007-00 (110V) 20-5010-00 (220V) 8000 South Kolb Road Tucson, AZ 85756 Phone 800.528.1597 Fax 520.885.1189 www.wellsgrp.com email: sales@wellsgrp.com

GENERAL DESCRIPTION The Hercules is a high-powered suction system with three oil-less piston vacuum pumps. The system is designed to pull a vacuum on any closed container or any open process system. Vacuum is accomplished by mounting the vacuum pumps in parallel. When the system is connected, the air flow will come from the tip of the cannula through the tubing, collection system, overflow trap, bacterial filter and finally to the pumps evacuate the air from the lines, creating a vacuum pulling aspirated material in the same direction as the air flow. Aspirated material continues to the collection system under normal suction until the cannula is exposed to air again. SPECIFICATIONS Item number 20-5007-00 (110V) 20-5010-00 (220V) Weight 73 lbs. Dimensions 18-1/2" x 18" x 15" Configuration Mobile Maximum vacuum 29+ inches of Hg Maximum flow rate 6.8 cubic feet per minute 850 ml/min. (with specified tubing) Gauge Unit Inches Hg/kilopascals Overflow protection auto cutoff and in-line filter Sound level 53+/- 3db @ 6 ft. Pump Type 2 cylinder piston Number of pumps 3 Horsepower 1 hp CHECK LIST Carefully unpack the Hercules. Check that the following accessories are included in the package and were received in good condition. Hercules Canister Holder Vacuum Gauge Power Cord Foot Switch 1-box Sterile, Disposable Tubing (10 per box) 2-Bacterial Filters 1-Overflow Trap 1-box of Disposable Canister Liners (10 per box) User s Manual DVD Note: You will receive either 1 or 2 canisters, depending on which collection system you ordered. Baxter System...1 Canister Sorenson System 2 Canisters Quick Fit System...1 Canister Call Customer Service Immediately to report any damaged or missing items: 800-528-1597

COMPONENT DESCRIPTION Vacuum Pumps The Hercules uses three (3) 1/3 hp piston pumps Oil-less, non-lubricated piston and cylinder Permanently lubricated ball bearings Stainless steel valves Light weight aluminum components Long-life, high performance piston seals Twin fan cooling system UL recognized motors Thermal protected Balanced for low vibration operation Capacitor Circuit Breaker To protect the equipment and reduce shock hazard, a re-settable circuit breaker is installed on the right side, near the power cord outlet. If there is a voltage surge or the pump motor overheats, the circuit breaker will pop out. To reset, turn the Hercules off, push in the circuit breaker, and turn the Hercules on. If the unit fails to start, the Hercules may require a cool-down period or technical repairs. Note: Do not let technicians to by-pass the circuit breaker.

Control Valves Vacuum Control Operate Vacuum Control by turning pointer between High and Low (pressure is reduced). The vacuum gauge on the panel will indicate a pressure change. Note: The Hercules system has been calibrated at 2,500 feet above sea level to 26+ in. Hg. For each additional increase of 1,000, the vacuum should drop by 1" Hg. And conversely, for each additional decrease of 1,000, the vacuum should increase 1"Hg. Volume Control Operate the Volume Control by turning the pointer between High and Low (reducing the amount or volume of flow). Air flow is decreased. Note: Do not position both the Vacuum and Volume Control valves in the LOW position at the same time, as there will be no noticeable suction. Foot Switch The Hercules can be operated with or without a foot switch. OPERATION WITH FOOT SWITCH Plug the foot switch cord into the unit. Turn the Foot Switch and Power switches to the ON position. Press the pedal and the Hercules will start. Press the pedal again to stop the power of the unit. OPERATION WITHOUT FOOT SWITCH Turn the Power toggle switch to the ON position, leaving the toggle for the Foot Switch OFF. Note: The Power switch must be in the ON position before the unit will start.

OVERFLOW TRAP The Overflow Trap is designed to catch aspirated material which has by-passed, or overflowed, from the main collection canister. The fluid entering the trap will cause the ball inside the plastic jar to float up into the bell shaped tube, which will cause the vacuum to stop. Note: The plastic ball acts as a safety mechanism only. There is NO GUARANTEE that the ball will completely stop the power of the unit. If there is a problem with the overflow, please check the following: 1. The liner may be collapsing, causing material to overflow into the trap. 2. The collection system may be full. 3. The collection system may not be set up properly. NO ASPIRATED MATERIAL SHOULD BE ENTERING THE OVERFLOW TRAP AT ANYTIME. Read the trouble shooting section of this material for instructions to correct an overflow situation. SAFETY INFORMATION Read all instructions carefully before operating equipment. Avoid ingesting aspirated material into the pumps. Severe damage can occur to the pumping system upon contact with aspirated material. Always disconnect the power supply to the Hercules before servicing. Motors are thermally protected and will automatically restart when protector resets. Current leakage tests are performed and are certified within the AAMI maximum 300uA limit for medical devices. Safety checks should be scheduled according to purchaser s policies. Additional warnings and power requirements, which are part of the labeling, are located on the right side of the Hercules. Caution: Federal Law restricts this device to sale by or on the order of a physician.

SET UP AND OPERATION 1. Carefully remove the Hercules form the shipping carton. Be sure to save the box and packing material for convenient maintenance returns. 2. Read all instructions carefully before operating the unit. 3. After you have removed the Hercules, open the accessory box and locate the power cord and foot switch. Plug the foot switch into the Hercules. Plug the power cord into the Hercules, then into the power outlet. 4. Locate the vacuum gauge and connect the item to the quick-connect lock on top of the Hercules. 5. Turn the Power switch and the Foot Switch ON. 6. To test the unit, place a finger over the main suction hose coming directly out of the top of the Hercules. Note the reading of the vacuum gauge. Keep in mind that vacuum changes according to elevation. After checking the vacuum, turn the Hercules off. 7. Place the Overflow Trap between the 4 small metal pegs on the top panel of the Hercules. The arrow on the top of the overflow trap should point toward the vacuum gauge. 8. Connect the HEPA Filter to one end of the Overflow Trap using the 6" silicon tube. Connect the other end of the HEPA Filter to the main suction hose. Note: Change the HEPA Filter after 10 procedures or every 24hrs of use. 9. Locate the Collection System. Determine if the system is a Baxter, Sorenson or Quick Fit canister system, then read the applicable instructions included in this manual to set up the collection system. Set up the collection system as described. At this point, the following accessories should now be connected: Power cord and foot switch Vacuum gauge to quick connect Bacterial filter connected to the main suction hose and the 6" silicone tubing which is connected to the overflow trap Canister placed in the canister holder with liner intact The unit is now ready for operation.

BAXTER CANISTER SYSTEM SET-UP & OPERATION 1. Place canister on top panel of the Hercules inside canister holder. 2. Snap the red liner lid onto a soft-shell liner. Insert the hard-shell canister. 3. Plug the red hose on the canister into the top of the liner lid on the port marked Vacuum. 4. Attach the 9" piece of silicon tubing from the overflow trap to the red spout on the side of the canister. 5. The sterile aspiration tubing will connect to the port labeled: Patient THE CANISTER SYSTEM IS NOW READY FOR OPERATION. Note: Aspirated material should not enter the overflow trap at any time. If an overflow situation occurs, please do the following: 1. Turn off the power immediately. 2. Check the connections between accessories to make sure the unit was set up correctly. 3. Check for a crack in the canister. 4. Check the vacuum and volume settings (should be on high). Canister Bacterial Filter Overflow Trap Vacuum Gauge Canister Holder Main Suction Hose Baxter A collapsing liner bag or Aspirated material going into the overflow trap does not mean that something is wrong with the Hercules. An overflow situation indicates there is an interference with the liner bag vacuum.

SORENSON CANISTER SYSTEM SET-UP & OPERATION 1. Place canister on top panel of the Hercules inside canister holder. 2. Insert a Quick Fit liner into the canister and secure the lid. 3. Connect the piece of tubing that is connected to the liner lid to one end of the Tee connector. 4. Connect the 12" piece of silicon tubing from the overflow trap to the bottom of the bracket on the Canister. 5. The sterile aspiration tubing will connect to the liner lid on the port labeled: Patient THE CANISTER SYSTEM IS NOW READY FOR OPERATION. Note: Aspirated material should not enter the overflow trap at any time. If an overflow situation occurs, please do the following: 1. Turn off the power immediately. 2. Check the connections between accessories to make sure the unit was set up correctly. 3. Check for a crack in the canister. 4. Check the vacuum and volume settings (should be on high). Bacterial Filter Canister Overflow Trap Vacuum Gauge Canister Holder Main Suction hose Sorenson A collapsing liner bag or Aspirated material going into the overflow trap does not mean that something is wrong with the Hercules. An overflow situation indicates there is an interference with the liner bag vacuum.

QUICK FIT CANISTER SYSTEM SET-UP & OPERATION 1. Place canister on top panel of the Hercules inside canister holder. 2. Insert a Quick Fit liner into the canister and secure the lid. 3. Connect the piece of tubing that is connected to the bracket to the top of the lid. (as shown on picture) 4. Connect the 12" piece of silicon tubing from the overflow trap to the bottom of the bracket on the Canister. 5. The sterile aspiration tubing will connect to the liner lid on the port labeled: Patient THE CANISTER SYSTEM IS NOW READY FOR OPERATION. Note: Aspirated material should not enter the overflow trap at any time. If an overflow situation occurs, please do the following: 1. Turn off the power immediately. 2. Check the connections between accessories to make sure the unit was set up correctly. 3. Check for a crack in the canister. 4. Check the vacuum and volume settings (should be on high). Canister Canister Holder Bacterial Filter Overflow Trap Vacuum Gauge Main Suction Hose Quick Fit A collapsing liner bag or Aspirated material going into the overflow trap does not mean that something is wrong with the Hercules. An overflow situation indicates there is an interference with the liner bag vacuum.

MAINTENANCE All Aspirators are thoroughly checked by the Quality Assurance Department before being released for shipping. Inspect the unit upon receipt to insure the equipment was not damaged during shipping. The vacuum power should also be checked. Do not lubricate pumps. The oil-less components are sealed and packed with optimum level of lubricant, requiring no lubrication. Do not let liquid or aspirated material enter the pumping system. The mufflers (Part No. 16-5073) should be changed after approximately 80 hours of operation, or whenever the white filter inside the muffler becomes black. No scheduled maintenance is recommended. Follow the procedures established by your engineering department. Warnings are part of the labeling and are indicated on the Hercules. The serial number is stamped on a small metal tag, located on the left side of the Aspirator. Record the serial number. In-services on new equipment can be provided by telephone with either your sales representative, or our technical support staff. If additional information is needed, call Customer Service or Technical Support at 800-528-1597. Change HEPA Filter after 10 procedures or 24hours of use. PARTS LIST: ITEM PART NO. Hercules (110V) 20-5007-00 Hercules (220V) 20-5010-00 Power Cord (AC 110V) 20-5100-00 Power Cord (AC 220V) 20-5101-00 Vacuum Pump (1/3hp, piston, hi-flo, 2 each) 18-5057-01 Vacuum Pump (1/3hp, piston, hi-vac, 1 each) 18-5058-01 Internal Tubing Kit 17-5003-00 Mufflers (3 each) 16-5073-00 Footswitch (Single) 20-5102-00 Footswitch (Dual) 20-5103-00 Vacuum Gauge 16-5030-00 HEPA Filters (case of 10) 20-5201-00 Overflow Trap Complete Assembly 17-5100-00 Overflow Trap 6 Silicone Tubing 17-5101-00 Overflow Trap 9 Silicone Tubing 17-5106-00 Overflow Trap Ball 16-5107-00 Baxter Holder 20-5159-01 Baxter Canister 1500cc 20-5153-00 Baxter Disposable Liners 1500cc 20-5154-00 Standard Tubing, 9ft., sterile 24-5103-00 Flex B Tubing, 12ft., sterile 24-5102-02 Sorenson Holder 20-5159-00 Sorenson Canister 1900cc 20-5157-00 Sorenson Disposable Liners 1900cc 20-5158-00 MB Tubing, 9ft., sterile 24-5104-00 Flex A Tubing, 12 ft., sterile 24-5102-01 Quickfit Holder 20-5159-03 Quickfit Canister 3000cc 20-5156-00 Quickfit Disposable Liners 3000cc 20-5155-00 MB Ultra Limp, 9 ft., sterile 24-5104-00 Flex A Tubing, 12ft., sterile 24-5102-01

TROUBLE SHOOTING No Suction 1. Turn vacuum and volume control knobs to High. If one or both knobs are on Low, there will be no noticeable suction. 2. Check for a collapsing liner. 3. Remove bacterial filter and place a finger over the main suction hose. If there is no suction, turn the unit off, remove finger from hose, wait a moment, then turn the unit on again. Note: Before starting any suction procedure, let the Hercules go to full vacuum when switched on. During operation, if the Hercules is momentarily turned off, let the vacuum gauge indicator return to 0 before restarting the machine. All the air must clear from the vacuum lines before all the pumps will start again. Failure to follow this procedure can result in the loss of vacuum. Overflow Situation 1. Monitor the collection system for fluid level. Do not overflow. 2. A collapsing liner can cause the aspirated material to overflow into the overflow trap. 3. Check for a crack in the canister. This can cause the liner to collapse, resulting in an overflow situation. A collapsing liner bag does not mean that there is something wrong with the Hercules. Note: With proper operation and monitoring, at no time during any procedure, should an overflow situation occur. Broken Canister 1. Do not use a damaged canister. A damaged canister will cause the liner bag to collapse, causing the aspirated material to overflow into the overflow trap. WARNING Ingesting aspirated material into the pumping system can severely damage the pumps and void the warranty. If material is going into the overflow trap, check the collection system immediately to see if the liner bag is collapsing or is too full. If further assistance is needed, call technical support at 800-528-1597. Refer to the collection system section and instructions for proper set up.

WARRANTY Five (5) year on parts and labor from the date of shipment. Unauthorized handling of the Hercules will void warranty of the unit. Any aspirated material found to have been ingested into the pumping system will void the warranty. Retain the custom-made packing box with foam for returns. All returns require prior authorization from the Wells Johnson Quality Assurance Department. For questions about the warranty, call the Quality Assurance Dept: 800-528-1597 For technical assistance call Customer Service or Technical Support: 520-298-6069 800-528-1597 Rev. 100317 ECN 571