Evoke.9" HP Downlight Features Evoke.9 LED fixtures are now available with a higher performance LED module providing W, 8W or 0W of lighting power. Featuring the fit, finish and attention to detail of the existing Evoke line, bringing true performance and control in a fixed downlight, adjustable, wall washer and pinhole. Everything you desire from a small aperture recessed downlight with lumen delivery, energy efficiency, dimming control and color consistency is now a reality in Evoke. Product Overview Type: Recessed Square Downlight Wattage:, 8, 0 Lumen Output:,00 max;. Lm/W (spot optic) CBCP: 9,7 max (spot optic) Color Temp: 00K, 700K, 000K, 00K, 000K CRI: 8 typ. (700K, 000K, 00K, 000K) + typ. (00K, 700K, 000K, 00K, 000K) Crisp (8W max) & K Class A available : TRIAC & ELV (0V/77V) - % Dim Lutron Hi-lume A-Series (0V/77V) - % Dim Lutron Hi-lume H-Series (0V/77V) - % Dim 0-0V (0V/77V) - % Dim DALI dimming - % Dim Fixture Type Round/Square New Construction Trim Trimless Yes Yes Yes Yes See separate spec sheet for Round trim fixture Downlight Trimless Performance Chart Watts Delivered Lumens LPW CBCP Color Temp 0,70 000K-8 8* 9 8,788 000K-8 0*,00. 9,7 000K-8 Data is based on 000K-8 IES files available on website Data is Spot optic. See page for other beam spreads W thermal protector included on 8W & 0W Electrical Data W 8W* 0W* System Watts Amps System Watts Amps System Watts Amps 0V 0.09 8 0. 0 0.7 77V 0.0 8 0.0 0 0.07 Electronic constant current LED driver *W thermal protector included on 8W & 0W LIT-07 //7 Page of 7
Housing/Frame Ordering Information Model For New Construction E.9SD-HP-NC-A7 (New Construction) E.9SD-HP-CP-A7 (Chicago Plenum (CCEA) housing) E.9SD-HP-IC-A7 (Insulated Ceiling/Air Tight, W only) Style T - trimmed TL - trimless (not available for use with Grid ceiling) Wattage 8 (not available for use with IC housing) 0 (not available for use with IC housing) Voltage 0 77 0/77 (for use with IC housing only) Ceiling Mounting GB - gyb board, /8" deep collar GRID - grid, " deep collar (not availble for use with trimless option) For other ceiling type, consult factory (for non-dimming, select LE/TE option) LE/TE - TRIAC/ELV dimming HILUME-A - Lutron Hi-lume A Series dimming driver HILUME-H - Lutron Hi-lume H Series dimming driver 0-0V - 0-0V dimming; % dim DALI - DALI dimming; % dim Trim Ordering Information E.9SD-HP-A7 Model E.9SD-HP-A7 Style T - trimmed TL - trimless (not available for use with Grid ceiling) Color Temp 8 CRI + CRI 7-700K-8 9-00K-+ CRISP - Crisp 0-000K-8 79-700K-+ (8W max) - 00K-8 09-000K-+ CLA - K Class A 0-000K-8 9-00K-+ 09-000K-+ Finish Trimmed MBW - matte black, white flange MWW - matte white, white flange SLVW - matte silver, white flange Trimless MB - matte black MW - matte white SLV - matte silver Options/Accessories WET - wet location (not available for use with trimless option) Beam Spreads SP - spot, NF - narrow flood, 0 MFL - medium flood, FL - flood, 8 WF - wide flood, VWF - very wide flood, 0 LS - linear spread, 0 x 0 The "A" refers to the sequential revision in a year and "XX" refers to the year of update. Updates coincide with improved performance while not changing the overall fixture aesthetic and are reflected in the published performance data. Please contact your Amerlux representative for explanations of changes. LIT-07 //7 Page of 7
Specifications Application Retail and commercial ambient and task lighting Housing Construction 0 ga. steel painted matte black Formed aperture plate with /8" lip (GB-standard) Cast aluminum plaster frame with perforated face (for trimless option) Integral adjustable locking mounting bars Thermally protected Reflector Trim Construction Die-cast aluminum seamless reflector Painted finishes include matte white and optical matte black with matte white flange Wet location option adds clear glass lens and silicone flange gasket Optical Beam spreads: Spot, º; Narrow Flood, 0º; Medium Flood, º; Flood, 8º; Wide Flood, º; Very Wide Flood, 0º; ar Spread, 0º x 0º LED Color Temp Options: 00K, 700K, 000K, 00K, 000K CRI: 8 typ. (700K, 000K, 00K, 000K) + typ. (00K, 700K, 000K, 00K, 000K) Crisp* LED available, 8W max Class A** 000K (high CRI, high gamut) R9 Values: (8 CRI), (9 CRI) Binning: MacAdam (SDCM) Life: 0,000+ hrs, > 70% of initial lumens at 0,000 hrs *Crisp: Crisp Technology delivers the warmth of colors expected from a high CRI solution but also creates the natural crisp white color that is pleasing to the eye. It creates the most impactful lighting ever available, by revealing the richest whites and vibrant colors that pop. **Class A LED: Class A LED s have a CRI > 80 and a GAI > 80. CRI defines color Naturalness and GAI defines color Saturation. Both being high delivers rich colors and pure whites. Electrical Wattage:, 8, 0 Electronic constant current LED driver, 0V or 77V input (voltage specific TP on 8W & 0W) This product complies with IEEE C. for surge endurance up to.kv. Amerlux recommends using additional surge protection with this unit (supplied by others), surge and over voltage damage is not covered under warranty. s LE/TE - Leading Edge, TRIAC, forward phase/trailing Edge, ELV, reverse phase (standard) 0-0V, Lutron and DALI systems also available See pages -7 for more dimming information Finish Wet paint Mounting For Trimmed fixture: For use in T-grid or sheetrock ceilings, /8" - " standard For Trimless fixture: For use in sheetrock ceilings, ceiling thickness /8" Consult factory for other ceiling thicknesses or for use in millwork ceilings Certifications CSA damp as tested to UL 98 standards Damp location Wet location (optional) IC/AT (insulated ceiling) rated, W only, optional Warranty year limited warranty LIT-07 //7 Page of 7
Evoke HP Round Downlight: 7 / / 9 / / / / min - max Trimmed /8 7 /8 /8 /8 - ".9 7 /8 Ceiling cut out: 7 / dia. Trimless /8 7 /8 Plaster Frame Installation Detail (for trimless fixture only).9 / Ceiling cut out: / dia. /8 /8. Reflector Trim. Aperture plate. Ceiling ⅝. Cast Aluminum Plaster Frame. Plaster Skim Coat (by others). - Type F Thread Cutting Screw LIT-07 //7 Page of 7
FIXTURE DATA: (Complete photometric data (.ies format) available upon request) MULTIPLYING FACTORS: (Multiplying Factor is based on 000K-8 0V IES file on website) Wattage: W 8W 0W Factor: 0. 0.9.0 CCT: 700K-8 000K-8 00K-8 000K-8 Factor: 0.9.0.0.0 CCT: 00K-+ 700K-+ 000K-+ CRISP Factor: 0.7 0.80 0.8 0. 0W LED, 000K Spot (SP) Distribution, º LTL #7877 Lumens:,00 Narrow Flood (NF) Distribution, 0º LTL#7878 Lumens:,0 Flood (FL) Distribution, 8º LTL # 7880 Lumens: 97 Wide Flood (WF) Distribution, º LTL # 788 Lumens: 9 00 7 00 7 70 7 00 7 000 0 000 0 00 0 000 0 700 00 0 00 0000 000 000 000 0 0 0 0 0 0 0 0 0 97 709 89 9 0 8 89 7 7 0 00 80 8 7 0 9 877 9 7 8 Application Data: Wide Flood Flood Narrow Flood Spot 0 o Aiming Angle Horizontal Footcandles.0 7.9.9 7. 0.. 0.0 8....9.8.0 8.. 7. 87.. 0.0.9.9..9.8.0 0.9.9 7. 9.0. 0.0 9... 9..8.0 70.. 7. 0.9 0.0 9... 8. 8. W D L FC Notes and Definitions: Beam spread is to 0% center beam candlepower (CBCP). D=Distance to floor or wall. FC=Footcandles on floor or wall at center beam aiming location. L=Effective Visual Beam length in feet (0% of maximum footcandle level). W=Effective Visual Beam width in feet (0% of maximum footcandle level). CB=Distance across or down to center beam location. LIT-07 //7 Page of 7
DIMMING COMPATIBILITY: Amerlux Evoke fixtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. Amerlux recommends testing your unique dimming configuration as the exact full configuration (Dimmer, Fixture Quantity, Voltage, etc) may affect dimming performance. TRIAC (Forward Phase) DIMMING (Standard) Utilizes Standard incandescent dimmers that are in wide use in installations across the US. Best for retrofit applications where TRIAC dimmers are installed. 0V or 77V* Dims down to less than % light output (most cases) Consult manufacturer for installation Must meet dimmer Minimum Load Requirements per dimming manufacturer Wall Box (Incandescent Style, Wattage as required) Lutron Diva Lutron Vareo Lutron Nova-T Lutron Skylark Lutron Maestro TRIAC Wiring Diagram TRIAC ETC SR Rack w/d0 Module Lutron GP Panel ETC DRD Rack w/d0 Module Lutron Grafik Eye QS ELV - Electronic Low Voltage (Reverse Phase) DIMMING (Standard) Utilizes specialized ELV dimmers. Best for New Construction applications ELV Wiring Diagram 0V or 77V* Dims down to less than % light output (most cases) ELV Consult manufacturer for installation Must meet dimmer Minimum Load Requirements Wall Box (ELV Style) Lutron Diva Lutron Nova-T Lutron Maestro Leviton Surslide Lutron Vareo Lutron Skylark Leviton Vizio ETC SR Rack w/elv0 Module Lutron GP Panel with PHPM-PA Interface ETC DRD Rack w/elv0 Module Lutron Grafik Eye QS with PHPM-PA Interface 0-0V - DIMMING (-0-0V Option) Integrates into a variety of building management and daylighting controls 0-0V Wiring Diagram 0V or 77V* Dims down to % light output Requires interface to turn off power to driver Consult manufacturer for installation 0-0V Gray Purple 0-0V (-) 0-0V (+) Switched Hot Wall Box Lutron Diva - DVTV with PP- 0H Interface Leviton Renoir II 0-0v Lutron Grafik Eye with GRX-TVI Interface * is 77V dimmable with appropriate dimmer (by others). All provided wiring diagrams show 0V wiring colors and method. Please refer to 77V dimming installation instructions for 77V wiring diagrams. LIT-07 //7 Page of 7
DIMMING COMPATIBILITY: Amerlux Evoke fixtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. Amerlux recommends testing your unique dimming configuration as the exact full configuration (Dimmer, Fixture Quantity, Voltage, etc) may affect dimming performance. LUTRON A-SERIES HI-LUME / ECOSYSTEM (-DIM-HILUME Option) Integrates into Lutron EcoSystem building management -Wire Wiring Diagram 0V or 77V* Dims down to less than % light output May use -Wire or EcoSystem Consult manufacturer for installation Cap unused ECOSYS wires -Wire Phase Purple Stripe Purple Orange E E Dimmed Hot Switched Hot Wall Box (-Wire Fluorescent) DIVA Maestro Nova T Vareo Lutron EcoSystem compatible controls ETC SR Rack w/d0f Module ETC DRD Rack w/d0f Module EcoSystem Digital Wiring Diagram E E ECOSYS Bus EcoSystem Purple Stripe E Purple E (Cap off Orange wire) Orange Dimmed Hot Switched Hot DALI DIMMING (-DALI OPTION) Digital control protocol allows individual fixture control DALI Wiring Diagram 0V - 77V* Dims down to % light output in most cases Wall Box (-Wire Fluorescent) Leviton CD0 ler DALI DALI Bus Purple Purple/WT Dynalite Fifth Light * is 77V dimmable with appropriate dimmer (by others). All provided wiring diagrams show 0V wiring colors and method. Please refer to 77V dimming installation instructions for 77V wiring diagrams. LIT-07 //7 Page 7 of 7