Startup Checklist. check off executed action! Altherma EHS(X/H) Daikin Altherma EHSX Altherma EHSXB Altherma EHSH Altherma EHSHB -08P50AA -16P50AA

Similar documents
INSTALLATION AND OPERATION MANUAL

1/8. Field settings table. Applicable indoor units. *GSQH10S18AA9W ThermaliaC12* Notes - *GSQH10S18AA9W / ThermaliaC12* 4P C

Installation and servicing instructions

Boiler controller S-Tronic Plus

Condensing Boiler RS100 Controller Training Program

Public. Altherma by Daikin. Altherma Commissioning Service Field Settings

Electronic Pellet Burner Controller NPBC-V3-1

Heating Controller SDC. District Heating Controller DHC 43 OPERATING INSTRUCTIONS

prestige Control Application Supplement - Type 5 MCBA WARNING

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller

1/8. Field settings table [6.8.2] =... ID66F3. Applicable indoor units *HYHBH05AAV3 *HYHBH08AAV3 *HYHBX08AAV3. Notes - 4P E

ENVI Boiler Controller

Field settings table [6.8.2] =... ID66F2. Applicable units *BLQ05CAV3 *DLQ05CAV3 *BLQ07CAV3 *DLQ07CAV3. Notes (*1) *B* (*2) *D* 1/8

SA-3841 User Manuel. 1U 4 Fans Unit with Thermostat Sensor. Version 1.1 Copyright All Rights Reserved

Boiler controller Lambdatronic S 3200

ELECTRIC BOILERS FOR CENTRAL HEATING

System Installation. multi-zone heating

User instructions DHP-AT

OPERATION MANUAL. Indoor unit for hot water heat pump system and options EKHBH016AB EKHBX016AB

Generator Control Unit, GCU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

Parameter guide 95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER WARNING WARNING

ir-range 8G /03.15 Changes reserved.

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

Electronic Pellet Burner Controller NPBC-V3M

Engine Control Unit, ECU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

PROGRAMMABLE 7-DAY THERMOSTAT

1/8. Field settings table. Applicable indoor units *HYHBH05AAV3 *HYHBH08AAV3 *HYHBX08AAV3. Notes - 4P C

Multi Boiler Guide. Kit #

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

Ice Rink (Single and Dual Configurations) Custom Control Features

Compact Genset Controller, CGC 400 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

RVL471 Heating and Domestic Hot Water Controller Basic Documentation

MCD User Manual

District heating controller for two heating circuits and d.h.w. according to Siemens specifications:

E8 Controller and BCM for Modulex EXT GF-136-C USER MANUAL. Installation, Operation & Maintenance

E System Manager Operating instructions

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

M116 / M450 USER AND MAINTENANCE MANUAL FOR MODULATING-CONTROL BOILER WITH GAS BURNER EQUIPPED FOR NATURAL GAS. Type : B23 ATLANTIC 2000

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

prestige Control Application Supplement - Type 5 MCBA WARNING

GREENSOURCE HYDROLIGHT AND HYDROCOMFORT

USER'S INFORMATION MANUAL

Operating instruction. Remote control station WCM-FS /

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

Comfort Control 2 HD Thermostat

SEMTIC HEATING

Operating instructions

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

IDEAL E-NERGY Thermostat Touch type User Manual

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

Operating Instructions for use by heating contractor. VITOTRONIC r 100 VITOTRONIC r 300-K IMPORTANT

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

Toll Free: Tel: Fax:

Installation and Operating Manual. Merlin 5064 V3. System Manager

O CRC100. Comfort Room Controller (2015/01) en

Operation manual. Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB

USER'S INFORMATION MANUAL

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

Description of the application programme for KNX occupancy detectors version 3.1

Control Panel Checklist

Installation and operation manual

INSTALLATION AND OPERATION MANUAL

Operation manual. Daikin Altherma Low temperature split EHBH04CBV EHBH08CBV EHBH11CBV EHBH16CBV

Autoclave Operations Manual

Daikin Altherma high temperature remote controller guide for schedule timers and operation functions

Type ETO2. Controller for ice and snow melting 67222A 04/14 (JRK) GREEN COMFORT Maximum comfort with low energy consumption OJ Electronics A/S

Temperature Controller CC24-7 UNIBOX USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)

Operating Instructions. Luxtronik. Heating- and Heat Pump Control

ER65 - Mini Rack Controller Electronic Refrigeration Line

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252

G a

Heating and D.h.w. Controller RVL482 Basic Documentation

USER'S INFORMATION MANUAL

Refrigerated air dryers

Heating Controller SDC Remote Heating Controller DHC

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning

Diplomat Inverter/Diplomat Duo Inverter

ETN-24-SUPER-SF Series

Heating Controller SDC Remote Heating Controller DHC

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler

prestige Control Application Supplement WARNING

VIESMANN. Operating instructions VITOTRONIC 200. for the system user

PROGRAMMABLE 7-DAY RF THERMOSTAT

G2484. Installation. - Control panel (in the panel front, on the inner wall, or on a DIN rail)

Basic Plus2 Room Thermostats Floor Heating

Boiler controller Lambdatronic S Touch

Installation, Operation and Maintenance Manual. RQ Series. Mold Temperature Control Units 0.75 to 7.5 hp and 0 to 24 kw

Installation Guide. ECL Comfort 210, application A Table of Contents

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO

USER'S INFORMATION MANUAL

Installation and service instructions

ALFEA. Commissioning & Services

Follett Performance Plus

Control Application. Supplement - ACVMax

Operating instructions THETA control unit for heating contractors. ROTEX control unit: - THETA 23R - THETA RS - THETA HEM1

Transcription:

Startup Checklist check off executed action! Daikin Altherma EHSX Altherma EHSXB Altherma EHSH Altherma EHSHB -08P50AA -16P50AA Daikin Altherma EHSX Altherma EHSXB Altherma EHSH Altherma EHSHB -04P30AA -08P30AA Altherma EHS(X/H)

Startup Checklist Check off executed action! 1 Initialization: Supply internal device and outdoor unit (if present) with power; pay attention to instructions on the display and follow them Confirm message with Yes Figure 1-1 Initialization runs, parameters are applied Wait until standard prompt appears Figure 1-2 Attention: Installations without outdoor unit -Crossed-out outdoor unit Figure 1-3 If at the time of startup no outdoor unit is yet present, a crossed-out outdoor unit is shown at the top of the display This icon has no influence on the startup of the system If the symbol is shown when an outdoor unit is used, there is an error (Error memory entry 9041) 2 Parameter settings for initial startup ATTENTION! Before entering/adjusting the parameter, enter "Expert code" ( RoCon HP / Chapter 361) The expert code is intended exclusively for the specialized company and may not be passed on to the end customer! 21 Activate Air Purge: ( RoCon HP / Chapter 3610) 22 Startup- Parameters: all of the following parameters must necessarily be set follow the sequence of Table 2-1 (for chapter information, see RoCon HP) 2 ZB EHS(X/H) - setup -00814 219 44_05-09/2014

Rotary switch main menu Select main level Push/turn control Select (turn) and confirm (push) menu level 1 / Parameters Exit button Return to main level (push) Figure 2-1 Controls Control unit Parameters Main level Rotary switch main menu Prompts on the Display Menu level 1 Parameter Setting value Comments 1 Configuration Setup ( RoCon HP) Outdoor type XX kw Power of outdoor unit Set size of outdoor unit (even if it is not yet installed) XX kw see rating plate Chapter 521 / 2 Tab5-1 Indoor Unit XXX Type of indoor unit Set type of indoor unit XXX see rating plate 3 System Configuration Power DHW 6 kw set to 6 kw or maximum value of the built-in Heating Rod 4 ( RoCon HP) BUH s1 power 3 kw 1st step of the heating support 5 Chapter 522 / Tab5-2 BUH s1 power 9 kw 2nd step of the heating support 6 HC Configuration ( RoCon HP) heating / T-Outside lim day 19 C Set to desired temperature 7 Chapter 523 / Tab5-3 Insulation underdose Depending on the setting, the external temperature is averaged over a specific time 8 DHW Set Temp ( RoCon HP) Chapter 57 T-DHW Setpoint 1 48 C Set to desired DHW-target temperature Not below 40 C! 9 Operating Mode ( RoCon HP) Chapter 54 heating activate Device begins to heat Attention: If the device was on standby, pay attention to the standby time; see Page 4 on 10 Information Switch to Info level Tab 2-1 ZB EHS(X/H) - setup -00814 219 44_05-09/2014 3

Startup Checklist Check off executed action! ATTENTION! If standby was set (Figure 2-2), you have to wait until the symbol "heating" and the flow temperature of the heat source are shown (Figure 2-3) This process can take up to 5 minutes Flow temperature of the heat source ---- = Standby Standby Flow temperature of the heat source XX,X C = Flow temperature Heating Figure 2-2 Figure 2-3 ATTENTION! With external temperatures under -2 C and a storage temperature under 30 C With external temperatures under 12 C and a storage temperature under 23 C the compressor does not switch on In this case, the storage is heated using the electronic heating element For this reason, no compressor symbol (next to the date) is shown on the display 23 Standard prompt for startup Compressor symbol DHW-temperature Figure 2-4 The startup is finished when the DHW-temperature is shown on the display to be above 40 C 24 Screed Program: When necessary: Activate floor screed program only after conclusion of the startup, as soon as the storage is warmed to at least 40 C (also possible without outdoor unit) (On this see RoCon HP / Chapter 3613) 3 Set operating parameters If no floor screed function is needed, please check the correct setting of the parameters Heat-Slope, T-Outside lim day, Operating Mode, Set Temp Day, Equilibrium Temp (supported by the electronic heating element in heating mode) and T-DHW Setpoint 1-3 ( 40 C) 4 ZB EHS(X/H) - setup -00814 219 44_05-09/2014

31 Overview of the main operating parameters It is imperative that you check the settings after the initial startup Pos Parameter Description / Explanation 1 Outdoor type Set size of outdoor unit (even if it is not yet installed) Read power (xx kw) from rating plate and set RoCon HP Ch 521, Tab5-1 2 Indoor Unit Set type of indoor unit Read type XXX from rating plate and set 3 Function Heating Rod When using an Heating Rod (electronic heating element) to support the heat pump, please set to 1 4 Equilibrium Func When activated, the electronic heating element for heating support is first triggered below the external temperature set in the parameter "Equilibrium Func" 5 Room thermostat When using a room thermostat (RT), you must set the parameter to "On"; only the RT contacts on the circuit board (Connection J16) also be evaluated (Interlinc fct) As soon as the parameter is activated, the system runs only when the RT contact is closed in heating-/cooling mode / frost protection function 6 Interlinc fct Flow target temperature is adjusted when the second RT contact (cooling contact, Connection J16) is closed to the value set in parameter T-Flow CH adj" or T-Flow Cooling adj ( RoCon HP, Ch 522, Tab 5-2) 7 Max Perform Pump 8 Min Perform Pump Defines maximum pump output Defines minimum pump output 9 Power DHW In order to expedite the heating process without an outdoor unit and ensures the highest warm water comfort, set this parameter to 6 kw, or the maximum value of the built-in electronic heating element Ch 522, Tab5-2 10 BUH s1 / s2 power Defines the output of the installed electronic heating element, which is connected at the respective stage, and limits the output that is taken for the heating support of the storage tank through the mixing valve If, during heating support with the electronic heating element, the storage becomes too warm or cools off too much, a sensor drift can occur This can be counteracted by adjusting the set parameter value according to Tab 3-4 11 Insulation Depending on the building insulation, the external temperature is averaged over a specific time Thus, it can happen that the heat pump does not switch on immediately when the external temperature falls below the parameter value "T-Outside lim day" The averaged external temperature can be seen in the Info level under info value T-Outside" Ch 523, Tab5-3 12 T-Outside lim day If the averaged external temperature falls below this temperature, a heating operation of the system is enabled (summer shutdown) 13 Heat-Slope Heat curve must be adapted for the respective house 14 Room Influence When a room controller EHS157034 is used and a room temperature-driven control is desired, this parameter should be selected >0 15 1x Hot Water After the target value is reached, this parameter MUST be deactivated; otherwise, the storage is always kept at 37 C Recommendation: Always let this parameter be deactivated (Setting 0)! Ch53, Tab5-5 Tab 3-1 (1/2) ZB EHS(X/H) - setup -00814 219 44_05-09/2014 5

Startup Checklist Check off executed action! Pos Parameter Description / Explanation RoCon HP 16 T-Room 1-3 Setpoint 17 T-DHW Setpoint 1 These parameters affect, in addition to the external temperature, the heat curve and possibly the room temperature detected by the room controller EHS157034 (if present and configured), the flow target temperature for the heating circuit If these parameters are set incorrectly, this can strongly affect the operation of the heat pump in heating mode Target value of the warm water temperature At startup, do not set below 40 C After startup, never set below 35 C! Ch55, Tab5-7 Ch57, Tab5-9 Tab 3-1 (2/2) Setting values for the parameters BUH s1 power" / BUH s2 power": Variables for energy withdrawal for equalization of sensor drift or system adjustment: Tab 3-2 Parameter set value [kw] Power rating of the installed electronic heating element [kw] Removal for heating support through mixing valve [kw] 1 0 1 2 3 2 3 3 3 4 3 4 5 6 5 6 6 6 7 6 7 8 9 8 9 9 9 10 9 10 11 9 11 9 9 6 ZB EHS(X/H) - setup -00814 219 44_05-09/2014

ZB EHS(X/H) - setup -00814 219 44_05-09/2014 7

Copyright Daikin 00814 219 44_05 09/2014