gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comment

Similar documents
OPTICAL TIME DOMAIN REFELECTOMETER (OTDR): PRINCIPLES

OPTICAL TIME DOMAIN REFLECTOMETRY (OTDR) Dr. BC Choudhary Professor, NITTTR, Chandigarh

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

LAB REPORT SUBMISSION COVER PAGE ETN4106 OPTOELECTRONICS AND OPTICAL COMMUNICATIONS

PC474 Lab Manual 1. Terry Sturtevanta and Hasan Shodiev 2. Winter 2012

PC474 Lab Manual Wilfrid Laurier University 1

Fibre Optic Basics FIA Summer Seminar 2014

Omnisens DITEST TM FIBER OPTIC DISTRIBUTED TEMPERATURE & STRAIN SENSING TECHNIQUE

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise

Ensuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis

ASSMANN ELECTRONIC GmbH ASSMANN SYSTEM GUARANTEE. DIGITUS Professional Fiber Optic Cabling System. Appendix B - Provisions for acceptance

FACULTY OF ENGINEERING LAB SHEET OPTICAL COMMUNICATION SYSTEMS EOP4066 TRIMESTER 1 (2013/2014)

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications

Optical Time Domain Reflectometry (OTDR)

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links

A Fresnel Reflection-Based Optical Fiber Sensor System for Remote Refractive Index Measurement Using an OTDR

Field Test Procedure for Optical Fibre Link Measurements

ANALYSIS OF OTDR MEASUREMENT DATA WITH WAVELET TRANSFORM. Hüseyin ACAR *

High cost performance choice

Ensuring Cabling Performance in the Customer-Owned Outside Plant

Fli'l HEWLETT. Measurement of Raylelgh Backscattering at 1.55 urn with a 32 um Spatial Resolution

GAMMA OTDR application consists of main window and menu. Using menu user can operate in different modes of application.

Distributed Temperature Sensing

Specifications Wavelength Range: 190 nm to 800 nm continuous

Benefits of Enhanced Event Analysis in. Mark Miller

High cost performance choice

Fiber optic distributed pressure sensor for structural monitoring applications

Methodology of Implementing the Pulse code techniques for Distributed Optical Fiber Sensors by using FPGA: Cyclic Simplex Coding

RAMAN SCATTERING AND OTDR BASED DISTRIBUTED SENSOR FOR TEMPERATURE MONITORING APPLICATIONS

OTDR - FHO5000-xxx. Optical Time Domain Reflectometer

Luna Technologies Webinar Series. New Rayleigh-Based Technique for Very High Resolution Distributed Temperature and Strain Sensing

The Rise of Tier 2 Testing

Vision Protection From Lasers Overview for Dr. Beagley, Australia

Table of Contents. Introduction... 1 Fiber Optic Communications... 1 Testing Optical Fiber For Loss... 2 Other Fiber Tests... 2 OTDR Applications...

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.

Understanding total measurement uncertainty in power meters and detectors

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

Unattended Radiation Sensor Systems for Remote Terrestrial Applications and Nuclear Nonproliferation

OFS IV Optical Fibre System

Correlation-based OTDR for in-service monitoring of 64-split TDM PON

Certified Fibre Optic Specialist - Testing

MTTplus Modular Test Platform

Long-distance remote simultaneous measurement of strain and temperature based on a Raman fiber laser with a single FBG embedded in a quartz plate

DURIP: Fast Oscilloscope and Detectors for Air Laser Research

Flexibility, scalability andsecurity

OTDR. Optical Time Domain Reflectometer. User Guide

REAL-TIME PROCESSING OF A LONG PERIMETER FIBER OPTIC INTRUSION SYSTEM

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

M700-Series Multifunction OTDR

FIBER OPTIC TESTING JIM HAYES OVERVIEW

Beam Loss Position Monitoring with Optical Fibres at DELTA

Noyes OFL 250B Specs Provided by

FIBER OPTIC TESTING 1

Fibre (TIA) Field Test Specification

AV6419 BOTDR. Product Overview. Main Features

DEGRADATION OF OPTICAL FillERS AT CARBON-CARBON PYROLYSIS. Rockwell International Science Center P.O. Box 1085 Thousand Oaks, CA 91358

IDEAL INDUSTRIES, INC. USER MANUAL IDEAL OTDR

A Novel Approach for a Hostile Arms Fire Sensor

Interferometric optical time-domain reflectometry for distributed optical-fiber sensing

Distributed Rayleigh scatter dynamic strain sensing above the scan rate with optical frequency domain reflectometry

ETSI TS V1.2.1 ( )

AV6416 OTDR. Product Overview: Main Features:

Draft ES V1.1.1 ( )

The Optical Scattering Calibration System at SNO+ IOP 2015

Polarized Light Scattering of Smoke Sources and Cooking Aerosols

M210 Multifunction Micro OTDR

M210 Multifunction Micro OTDR

Optical Time-Domain Reflectometry for the Transport Spatial Filter on the OMEGA Extended Performance Laser

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

Direct measurement of the aerosol absorption and extinction cross section for a variety of chemical and biological simulants in the LWIR

INTERNATIONAL STANDARD

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

HALON FLIGHTLINE EXTINGUISHER EVALUATION: DATA SUPPORTING STANDARD DEVELOPMENT [INCLUDES NOVEMBER 2007 ADDENDUM]

OPX-BOX. Platform Highlights. Software Support. Key Features

Temperature Data Logging

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

FLX380-30x FlexTester OTDR

FTB-7400E Metro/CWDM OTDR METRO/CORE AND CWDM NETWORK FIBER CHARACTERIZATION

Experimental Study to Evaluate Smoke Stratification and Layer Height in Highly Ventilated Compartments

An FT-NIR Primer. NR800-A-006

Journal of Applied Science and Agriculture. Improve the Spatial resolution of distributed optical sensors by designing a new detection scheme

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

ProStar 325 UV-Vis Detector

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR FUSION SPLICE AND SPLICE ENCLOSURE FIBER OPTIC CABLE

Range Dependent Turbulence Characterization by Co-operating Coherent Doppler Lidar with Direct Detection Lidar

OPTICAL TIME-DOMAIN REFLECTOMETER

ECBC SBIR/STTR Projects. ECBC SBIR/STTR MSCoE STRF Conference

Praetorian Fibre Optic Sensing

FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series

CT398 Heaterstat TM Temperature Controller. Technical User Guide

Return loss measurement of fiber optic components

FTB-700 Series. OTDR for FTB-1. User Guide

Variable Temperature Microprobe Systems

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

DETECTION AND LOCALIZATION OF MICRO AND MULTIPHASE LEAKAGES USING DISTRIBUTED FIBER OPTIC SENSING

DSP EC Pro. Advanced, Digital Gamma-Ray Spectrometer for HPGe Detector Systems

Building and Characterizing 14GHz InGaAs Fiber Coupled Photodiodes

MINI2. Inno Mini 2 Specs Provided by MOST ACCURATE COMPACT OTDR

Transcription:

DTIC FILE COPY REPORT DOCUMENTATION AD-A224 606 188 Public reporting burden for this collection of Information Is estimated to average 1 hour per response. I gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comment ation. Including suggestionsfor reducing this burden. towashington Headquarters ServIkes, Directorate for InformationOeu w, =,..,,,. '"'i,,r.a 22202m43-2. and to the Office of Management and Budget. Paperwork Reduction Project (0704-0188). Washington. DO 20503. 1. AGENCY USE ONLY (Leave aw4 2. REPORT DATE 3. REPORT TYPE AND DATES COVERED July 1990 professional paper 4. TITLE AND SUBTITLE 5. FUNDING NUMBERS BACKSCATER SIGNATURE GENERATOR FOR OTDR CALIBRATION PE: 062233N WU: DN305061 6. AUTHOR(S) PR: EE97 C. Hui, N. Kamikawa, and K. Yamada 7. PERFORMING ORGANIZATION NAME(S) AND ADORESS(ES) 8. PERFORMING ORGANIZATION REPORT NUMBER Naval Ocean Systems Center San Diego, CA 92152-5000 9 SPONSCRING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSORING/MONITORING David Taylor Research Center Bethesda, MD 20084 AGENCY REPORT NUMBER 11. SUPPLEMENTARY NOTES 12a DISTRIBUTION/AVAILABIUTY STATEMENT 12b. DISTRIBUTION CODE Approved for public release; distribution is unlimited. 1 LBSTRACT (Maxrmum 200 words) This paper describes an active characterization technique that generates backscatter signatures to measure the performance of optical time-domain reflectometers (OTDRs). These signatures can be used tw test an OTDR's loss accuracy, dynamic range, spatial resolution, loss resolution, and receiver recovery time. '. DTIC JUL 16 1990 D C Published in SPIE, Vol. 1180 Tests, Measurements, and Characterization of Electro-Optic Devices and Systems (1989).,14. SUBJECT TERMS 15 NUMBER OF PAGES metrology logistics calibration electronic devices, components subsystem systems - 16 PRICE CODE 17. SECURITY CLASSIFICATION 18 SECURITY CLASSIFICATION 10. SECURITY CLASSWICATION 20. UMITATION OF ABSTRACT OF REPORT OF THIS PAGE OF ABSTRACT UNCLASSIFIED UNCLASSIFIED UNCLASSIFIED SAME AS ABSTRACT NSN 7540-01 -280-5500 Standard form 298

Backscatter signature generator for OTDR calibration Chun Keung Hui, Neil Kamikawa, Ken Yamada Naval Ocean Systems Center -- Hawaii Laboratory Advanced Fiber Optic Systems Branch P.O. Box 997 Kailua, Hawaii 96734 Abstract This paper describes an active characterization technique that generates backscatter signatures to measure the performance of optical time-domain reflectometers (OTDRs). These signatures can be used to test an OTDR's loss accuracy, dynamic range, spatial resolution, loss resolution, and receiver recovery time. Introduction No practical commercially available techniques, devices, or instruments exist today to measure the performance level of OTDRs. Consequently, measurement discrep" ies performed on OTDRs often cannot be resolved due to the lack of a traceab._ calibration standard. Several passive techniques have been proposed that use standard fibers, delay lines, and bulk optics as calibration standards. However, these techniques are not robust, mass producible, or flexible enough to characterize all crucial parameters for long and short haul OTDRs. We have developed an Optical Fiber Backscatter Signature Generator (OFBSG) as an active characterization system for OTDRs. The OFBSG system consists of an optical source, an optical receiver, a Z80 microprocessor board and some processing logic. The system resides in a light-weight, compact chassis, and interfaces with the OTDR via a short fiber optic cable as illustrated in Figures I and 2. The system detects the narrow pulses launched from the OTDR and returns a computer generated backscatter signature. These signatures can be imported from a lap-top computer and can be tailored for short-haul or long-haul OTDRs. This paper first reviews the definitions for OTDR parameters and tradeoffs between passive and active characterization methods. It is then followed by a description of the OFBSG concept, system overview, computer interface, test results, and conclusions. OTDR parameters A concise definition of OTDR parameters is necessary before discussing characterization techniques. OTDR manufacturers specify some of the parameters, but there is no concurrence in how these parameters are defined. The five most critical parameters are loss accuracy, dynamic range, spatial resolution, loss resolution, and receiver recovery time from overload. I SPIE Vol. 1180 Tests, Measurements, and Characterization of Electro-Optic Devices and Systems (1989) / 27

Loss accuracy specifies the difference between the measured and the actual loss value. Dynamic range is the difference in decibels between the noise floor and the upper limit of the linear range of the OTDR receiver. Spatial resolution specifies the ability of the OTDR to distinguish between defects or fiber perturbations in close proximity. It is determined by the full width of the Fresnel reflection pulse at half of tha maximum power (FWHM). 2 Loss resolution is the smallest resolvable loss measurement. The recovery time from receiver overload is the time required for the receiver to recover from saturation. Tradeoffs between passive and active characterization OTDR characterization methods can be divided into two categories: (1) passive devices using fiber standards, delay lines, and bulk optics; and (2) active devices that generate and detect optical signals. 1 Some of the advantages and disadvantages of each approach are discussed. Passive characterization using standard reference fibers is a simple and direct concept approach, but it has disadvantages. For example, long-haul OTDRs with distance capabilities greater than 100 km require standard reference fibers longer than 100 km. It is difficult to fabricate a fiber of this length with attenuation that is unaffected by packaging, temperature changes, and vibration. Since the standard fiber has fixed attenuation factor, the fiber signature cannot be changed. An active device such as the OFBSG overcomes these drawbacks by allowing length, attenuation, and other characteristics to be changed by modifying the backscatter signatures in the lap-top computer before importing it into the OFBSG. One disadvantage of the OFBSG is that it is more complex. Another disadvantage of the reference fiber is that the measurement of the dynamic range requires extrapolation of the backscatter returns at the upper and lower limits of the OTDR's receiver. 2 However, extrapolation may not detect nonlinear effects caused by receiver saturation in the "dead zone" region in the front end of the backscatter returns. If the fiber is too short to measure backscatter near the noise floor, the lower end of the dynamic range must also be extrapolated. Hence, effects of incorrect bias levels in the logarithmic amplifier may not be detected. 1 The backscatter that the OFBSG returns to the OTDR can be programmed for length and attenuation to eliminate the need for C, extrapolation. /+CO a We selected the active characterization method because its advantages over the passive techniques outweighed the added complexity. Furthermore, the optical source in the OFBSG can be easily calibrated against transfer standard power meters for NIST-traceable measurements. Unlike the reference standard, the OFBSG can be computer controlled to tailor signatures for measuring all five critical operating parameters described earlier. In addition, this system can be setup to characterize single-mode and multi-mode OTDRs in different wavelengths by simply substituting the LED and coupler to match the OTDR's wavelength and modal characteristics. Backscatter signature concept Backscatter signatures returned to the OTDR by the OFBSG were designed to appear as fiber Rayleigh backscatter given by equation I. 1 28 / SPIE Vol 1780 rests, Measurements. and Characterization of Electro-Optic Devices and Systems (7989)

0.5 0oWVg [ asfs + anfn I exp I -atvgt (I) Vg = Group velocity a s = Rayleigh scattering attenuation coefficient Fs = Rayleigh capture fraction a n = Non-Rayleigh scattering attenuation coefficient Fn = Non-Rayleigh capture fraction at = as + an (o = Peak power injected into the fiber W = Pulse width The Rayleigh backscatter in a fiber decays exponentially with distance, Rayleigh scattering factor, and non-rayleigh scattering factor. Hence, in order to simulate the Rayleigh backscatter in a fiber, the backscatter signal generated by the OFBSG decays with time and other scattering factors. This concept allows OTDRs to be tested and characterized using signals that are as realistic as possible. OFBSG System Overview The OFBSG system illustrated in Figure 3 is comprised of a Z80 microprocessor board, random access memory (RAM), a Digital-to-Analog converter (DAC), a Light Emitting Diode (LED), a directional fused-taper coupler and an optical receiver. The generation of the signature is initiated upon the receipt of the output pulse from the OTDR. Once the optical receiver-pulse detector senses the incoming pulse, a pre-loaded backscatter signature data in the RAM is sequentially applied to the DAC. The LED converts the analog output of the DAC into an optical signal. The optical backscatter signature signal then launches through the 3 db fused-taper coupler into the OTDR. Each data point is represented by-a twelve bit digital value. This means that the signal can be signified by any of the 4096 (212 = 4096) steps. The number of bits in the DAC defines the inherent loss resolution of the system as described in equation 2. Po max Loss resolution = 10 log [ P - of steps] (2) Pi Pi - Input power Po max - Maximum output power SPIE Vol 1180 Tests Measurements. and Characterization of Electro-Optic Devices and Systems (1989), 29

The inherent spatial resolution of the system is limited by the width of the pulse launched from the OTDR and the clock speed of the OFBSG. There are three selections for clock speeds of 5, 10 and 20 MHz and they correspond to 20, 10 and 5 meters of spatial resolution, respectively. However, even if the OTDR's receiver could resolve a 5 meter distance, the OTDR's transmitter pulse width may only be as small as 100 nanoseconds which translates into 10 meters of spatial resolution. Therefore, considerations must be made in conjunction with the OTDR transmitter pulse width and the response of the OTDR's receiver when determining spatial resolution. Equation 3 defines the OFGSB spatial resolution limit. ct X 2n (3) c = speed of light in vacuum t = period of each data point n = index of refraction of the core Computer Interface A varicty of backscatter signatures can be loaded into the RAM from the laptop computer depending on which OTDR parameter is being measured. The user first determines the characterization parameters by choosing the selections on the software menu as shown Figure 4. After the parameters are selec:ed, the software calculates and produces the backscatter signature data points. These signatures are uniquely made to specifically test the five OTDR parameters. For example, a signature with a non-saturating Fresnel reflection is generated to measure spatial resolution. The computer downloads all data points via the RS 232 serial interface to the Z80 microprocessor board. It is then transferred to the RAM and sequentially applied to the DAC to generate the analog backscpc er signature for the LED. A typical computer generated signature is shown i'. Figure 5. Test Results The performance levels of three single-mode 1.3 micron OTDRs that were available in the lab were tested with -.ur system. Figure 6 shows the preliminary test results of the four tests perfotmed on these OTDRs. A signature with 0.10 db and 0.20 db splice losses was used to measure loss accuracy. OTDRs I and 2 exhibited close correlation to the input loss values. However, the rebults for OTDR 3 significantly deviated from these values. Spatial resolution, loss resolution and receiver recovery time tests were also performed. It appears that OTDR I performed the best under all four tests and OTDR 3 performed thu worst as evidenced by the large loss deviation and long recovery time. These results correlate to the age difference between the two OTDRs. OTDR I was acquired about two years ago while OTDR 3 was purchased nearly six years ago. Hence, the performance of OTDR I probably reflects improvements 30 /SPIEVol 1180 Tests, Measurements, and Characterization of Electro-Optic Devices and Systems (1989)

in OTDR technology. Also, OTDR 3 suffers from years of operation in sometimes adverse field environments without routine maintenance. Further testing will bemade upon completion of the computer interface and software, but the preliminary test results demonstrate that the OFBSG provides valuable characterization of OTDR performance. Conclusion In this paper, we discussed the OFBSG active characterization technique, its advantages, and preliminary test results. The major advantage of our system is its ability to uniquely generate any form of backscatter signature. Therefore, OTDR performance parameters described earlier and any additional parameters added in the future can be easily cnaracterized. (1) The backscatter signatures can be tailored to test multiple OTDR parameters. (2) The LED transmitter in the OFBSG system can be changed to accommodate different wavelength OTDRs. (3) It can also be tailored for single-mode or multi-mode by substituting the LED and the optical coupler. (4) This system is portable and light weight. It can be carried by one person to any remote site to perform the characterization procedures. Acknowledgement The authors wish to thank Arthur Nakagawa in providing invaluable assistance in all aspects of this project. This work is funded by the Equipment Performance Monitoring task of thp Navy's 6.2 Logistic Block Program. References 1. B. L. Danielson, "Optical time-domain reflectometer specifications and performance testing," Applied Optics, Vol. 24, pp. 2313-2322, August 1, 1985. 2. "Test set, fiber optic cable, optical time domain reflectometer (OTDR), portable, militarized, for field inspection of optical fibers, components and systems general specification for," Mil-O-BBBBB. 3. B. L. Danielson, "Backscatter Measurements on Optical Fibers," Optical Fiber Characterization, NBS Special Publication 637, Vol. 1, pp. 4-46, July 1982. SPIE Vol 1180 Tests Measurements. and Characterization of Electro-Optic Devices and Systems (1989) 31

Figure 1. Photo of characterization test setup. (left) OTDR under test. (middle) Optical Fiber Backscatter Signature Generator, OFBSG. (right) Laptop computer. OTDR Charatenization - Test Setup I i Gnemabr IOFDSG) L i RS232 FMLLZ Omek To Figure 2. OTDR characterization test setup. 32 / SPIE Vol 7180 rests, Measurements. and Characterization of Electro- Optic Oevices and Systems (7989)

OFBSG Block Diagram ZWD P IOCS.OR aam m ia LE NT'S OD DE'rECTOR C0UPLER Figure 3. OFBSG Block Diagram. OFBSG Menu File Create Cable Loss Accuracy Dynamic Range Recovery Time Spatial Resolution Loss Resolution Display Exit Figure 4. Main software menu. SPIE Vol. 1180 Tests, Measurements, and Characterization of Electro-Optic Devices and Systems (1989J / 33

OTDR 0 1300 nm 0 4 12 II 20 24 2. mstm (km) Figure 5. Typical computer generated backscatter signature. Test Results Parameters OTDRs OTDR 1 OTDR 2 OTDR 3 Accuracy (db) 0.13 0.13 0.24 0.20 0.25 0.77 Dynamic Range Spatial Resolution (m) 10 51 52 Loss Resolution (db) 0.01 0.01 0.01 Recovery Time (m) 41 34 60 Figure 6. Characterization test results of three OTDRs. 34 SPIE Vol 1180 Tests. Measurements. and Characterization of Electro-Optic Devices and Systems (1989)