Total Access 1500 SCU Installation and Maintenance

Similar documents
AC/DC Power Supply and Battery Charger Installation and Maintenance

USER MANUAL FOR OPERATING SYSTEM

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

P2267 NETWORK INTERFACE

High-Speed Voice and Data Link Access Multiplexer

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

21-light Remote Annunciator. Owner s Manual

Alarm Panel [ PRELIMINARY HARDWARE MANUAL ] USER MANUAL. v1.0a. May 7, 2008 D-OC-UM

ModBus DE-1 INSTALLATION AND USER MANUAL

LORAIN CIP 4890/48120 DC Power System

Galaxy Pulsar Plus Digital Battery Plant Controller

NetworX NX-548E Receiver Installation Instructions

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

FCD-wire Contents. List of Figures

IndigoVision Alarm Panel. User Guide

GDC 087R Issue 1 - May Installation and Operation UAS Network/Dropside Interface Unit Model NIU/DIU 7624.

UNC100 Integra Manual

Model 135 Reference Document

4100U City and Relay Cards Installation Instructions

CPS3200U Technical Support Guide

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

SCR100 User Manual. Version:1.1 Date:Dec 2009

LORAIN CSP DC Power System

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

239 T1 HDSL4 Repeater (H4R) Installation and Maintenance Practice

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

KTD-348 Crosspoint 32 Matrix Video Switcher

Alarm module for leak detection with webserver

VersAlarm. Installation & Operation Manual

IntesisBox BACnet/IP Server - Notifier ID3000 series

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

UAS 7000 Local Management

Carbon Monoxide Transmitter

VNC Versatile Network Controller Operation and Installation Manual

Installation, Configuration and User Manual

The system should also be capable of recording events automatically on any compatible DVR and should be able to retrieve recordings based on events.

Added password for IP setup page : Password must be in IP format!

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

User manual for CPR32-NET network controller

AKSolutions Data Sheet April 2007 AK882X RF POWER MONITOR. Description: Features:

Inner Range FE3000S. Serial GSM Modem. P/No: INSTALLATION MANUAL

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

PAPERLESS RECORDER COMMUNICATION FUNCTION (Ethernet)

MicroTech Series 200 Centrifugal Chiller

Manage Alarms. Before You Begin CHAPTER

Eclipse Nursecall Systems Ltd. Clipper Plus & Clipper ID. Document V.2.1b (Basic) ENS. Freedom Through Technology

Product Data Sheet. Remote Terminals. Features:

PowerLogic ION Setup Meter Configuration Software Configuration Guide

ACTIVE INFRARED BARRIER

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

HRX Technical Manual. Version 1.2

Manage Alarms. Before You Begin CHAPTER

Diagnostics and Monitoring System WEB Tool 2. User Manual

Laptop / PC Programming Manual

GE Security Fire & Life Safety F-DACT(F) Digital Alarm Communicator Transmitter Installation Sheet

Intelligent 2 & 4 Loop Fire Alarm Control Panels

User manual. KNXgal. version

Installation Manual. ATS Remote Annunciator Catalog 5310 DANGER WARNING A

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

DualCom GradeShift UDL QUICK GUIDE & INSTRUCTION MANUAL

IRIS Touch Firmware Enhancements and Additions from Version to Version

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

KT-100 Door Controller

mti085 Temperature Interface

Intelligent Single Loop Fire Alarm Control Panel

TECOM SYSTEMS NETWORK MASTER

20 Light Remote Annunciator

Galaxy Pulsar Plus Controller Family Troubleshooting Table with SMNP Traps

User manual. KNXpar. version

CARD ACCESS CONTROL SYSTEM

Model IOR-MA4280/4285 T1 Repeater) Mounting Shelf (4-Inch, 28-Position) User Manual)

FIRECLASS Networking. Addressable Fire Alarm Control Panels From Software version 21. Product Application and Design Information FC-A-FCNET-A

TELSEC MINI PRO User Guide

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

Refrigerated Incubator Model and Operating Instructions

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

D-TECT 2 IP. GJD230 IP Motion Detector

Metasys Integrator TITUS Application

PBI Manual. Paradox to KNX-BUS Interface

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

Mark 25 Ultrapure Water Conductivity Analyzer

OPERATOR INSTRUCTIONS FOR DM3000

CBI-064. User Manual. Caddx to KNX-BUS Interface

RS485 MODBUS Module 8AI

Yokogawa DX Ethernet Driver Help Kepware Technologies

Public Safety DAS Annunciator Panel

Rev D 3/20/17

OPERATING MANUAL. PCC Controller. (PCC-01 and G) [PCC-01 shown]

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

entri Series HE1U-XX12-BMS-MU Series

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

INSTALLATION INSTRUCTIONS

LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL

SCAN200E USER S MANUAL

Version 1.03 January-2002 USER S MANUAL

Transcription:

CONENS 1. GENERAL... 1 2. INSALLAION... 2 3. OPERAION... 3 4. MAINENANCE... 9 5. PRODUC SPECIFICAIONS... 9 6. WARRANY AND CUSOMER SERVICE. 10 FIGURES Figure 1. otal Access 1500 SCU... 1 Figure 2. System Controller Menu ree... 7 otal Access 1500 SCU Installation and Maintenance E S MJR RM SCU 1180008L1 HS A D M IN PWR Section 61180008L1-5B Issue 2, September 2002 CLEI Code L1: VAC1E40J CLEI Code L2: VAC1E4NJ CLEI Code L3: VAC14NJ SCU CO 1180008L2 E S MJR RM A D M IN HS ML BSY SCU R 1180008L3 E S MJR RM A D M IN HS ML BSY ABLES able 1. Compliance Codes... 2 able 2. Front Panel Description... 3 able 3. DCE Pin Assignments... 3 able 4. X.25 Pin Assignments... 4 able 5. Detailed SCU Specifications... 9 1. GENERAL his practice provides installation and operation procedures for an ADRAN otal Access 1500 System Controller Unit (SCU), common modules List 1, List 2, and List 3. Figure 1 shows the otal Access 1500 SCU, List 1, List 2, and List 3. he SCU comes in the following three configurations: List 1 No Mechanized Loop est (ML) capability. List 2 Central ice erminal ML List 3 Remote erminal ML Revision History his is the second release of this document. his version includes updates describing L1 over X.25 and CP/IP. Features he otal Access 1500 SCU, P/Ns 1180008L1, 1180008L2, and 1180008L3, includes the following features: Control all common equipment and access modules List 1 List 2 List 3 Figure 1. otal Access 1500 SCU Mechanized Loop est (ML) capability (L2 and L3 used together only) Provide V100 craft interface via front panel DB-9 connector Alarm Cut () pushbutton Bank status indicators est equipment timing output Meet NEBS Level 3 and UL 1950 requirements Provides alarm status to NMA and/or SNMP Provides internal PAD for X.25 network Software can be upgraded while in field without affecting service Operates in Host or Client mode for RS-485 chaining applications Supports L1 over CP/IP or X.25 Supports menu access over elnet L2 and L3 monitor primary and secondary power feeds. L1 does not monitor power feeds. General Description he otal Access 1500 SCU is a common module, plug-in unit designed for the otal Access 1500. he SCU provides all control functions for the otal Access 1500 common units and all the individual access modules. he SCU manages all network related functions and communicates externally 61180008L1-5B rademarks: Any Section brand names 61180008L1-5, and product names included Issue in 2this document are 1 trademarks, registered trademarks, or trade names of their respective holders.

through RS-232, RS-485, and Ethernet interfaces. he SCU manages the Mechanized Loop est (ML) feature and controls the activation/deactivation relays. Compliance able 1 shows the Compliance Codes for the otal Access 1500 SCU. he SCU complies with the requirements covered under UL 1950 and is intended to be installed in Restricted Access Areas only and in equipment with a ype B or E enclosure. he otal Access 1500 SCU plugs directly into the SCU slot in the common module area of the otal Access 1500 chassis. WARNING he otal Access 1500 SCU can only be inserted into the third slot of the shelf. Attempting to insert the SCU in any other slot may damage the SCU and/or the backplane. Code NOE At this point in the installation, power should not be applied to the otal Access 1500 shelf. able 1. Compliance Codes Input Output Power Code (PC) C C elecommunication Code (C) - X Installation Code (IC) A - his device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1. his device may not cause harmful interference. 2. his device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by ADRAN could void the user s authority to operate this equipment. 2. INSALLAION C A U I O N! SUBJEC O ELECROSAIC DAMAGE OR DECREASE IN RELIABILIY. HANDLING PRECAUIONS REQUIRED. After unpacking the unit, inspect it for damage. If damaged, file a claim with the carrier. hen contact ADRAN Customer Service. Refer to the Warranty and Customer Service section of this practice. Electronic modules can be damaged by static electrical discharge. Before handling modules, wear an antistatic discharge wrist strap to prevent damage to electronic components. Place modules in antistatic packing material when transporting or storing. o Install the otal Access 1500 SCU, perform the following steps: 1. Pull the latch/ejector on the bottom of the SCU front panel from its closed position. 2. Hold the unit by the front panel while supporting the bottom side. 2. Align the card edges to the guide grooves for the SCU slot. 3. Gently, but firmly, push the SCU into the third slot on the shelf. Simultaneous thumb pressure at the top and bottom of the SCU will ensure a good seat of the SCU pins into the backplane connector. 4. Lock the unit in place by pressing down the locking lever. All power, ground and administrative wiring should now be completed on the otal Access 1500 shelf, and an SCU should be installed in the shelf. he next procedure is to apply power to the shelf with an SCU in place, and ensure that the SCU properly powers up and successfully completes its power-on self-test routine. o verify that the SCU completes its self-test routine perform the following steps: 1. Insert a fuse into the fuse and alarm panel serving either the A or B power feeds to the otal Access 1500 shelf. he fuse should be selected with an amperage appropriate for the intended use of the otal Access shelf. 2. Verify that the SCU power-on self-test routine is successfully completed. he LEDs will all simultaneously flash, then the, HS, and ML BSY LEDs will flash four times staying on the last time. Once these LEDs turn off, the front panel will represent the true status of the SCU. his may take more than 1 minute. 2 Section 61180008L1-5, Issue 2 61180008L1-5B

3. his constitutes a complete and successful power-on test. NOE Once successfully powered up, if only A or B power is supplied, the SCU will reflect a MIN alarm for A (or B) power failure. 3. OPERAION Power he otal Access backplane delivers two -48 VDC buses to the SCU. he SCU operates with both or either -48 VDC buses active. Front Panel Indicators See able 2 for a description of front panel LEDs and buttons. User Interface Since the SCU is the user access point to the shelf and its access modules, it must support a number of user physical interfaces and service the shelf s communication buses. he SCU supports a craft port, X.25 port, and an Ethernet port. Craft Port he SCU provides an RS-232 serial asynchronous craft access port. Physical access is attained by connecting a male-ended DB-9 cable to the female DB-9 connector on the SCU front panel. his port can operate at various baud rates and is limited to 8-bit asynchronous data with no parity, one stop bit. Minimal 3-wire functionality (pins 2, 3, and 5) is also accommodated. his port operates as a DCE; pin assignments are detailed in able 3. Pin able 3. DCE Pin Assignments Number Function 2 ransmit Data from DCE 3 Receive Data into DCE 4 DR (Data erminal Ready) 5 Signal Ground X.25 Port he SCU supports synchronous RS-232 compatible serial interface to be used in conjunction with an X.25 network. he unit includes PAD functions onboard so an external PAD is not required for operation with the X.25 network. Physical access uses a 25-pin female DB-25 connector (J34) on the rear of the otal Access 1500 shelf. he X.25 connector pin assignments are detailed in able 4. SCU CO 1180008L2 E S MJR RM A D M IN HS ML BSY LED MJR RM HS ML BSY Switch able 2. Front Panel Description Color Description Red Yellow Yellow Green Green Green No Major alarm condition detected. Major alarm active (Red Alarm) No Minor alarm condition detected. Minor alarm active (Yellow Alarm) No Remote or Auxiliary alarm condition detected. Remote or Auxiliary alarm active switch not activated switch activated SCU is client for cluster group SCU is host for cluster group No ML test is active ML test is active Description Switch Press to disable any audible alarms only. remain active. Any active visual alarms will 61180008L1-5B Section 61180008L1-5, Issue 2 3

Pin able 4. X.25 Pin Assignments Number Function 1 Frame Ground (FG) 2 ramsmit Data (D) from DE 3 Receive Data (RD) into DE 4 Request o Send (RS) 5 Clear o Send (CS) 6 Data Set Ready (DSR) 7 Signal Ground (SG) 8 Data Carrier Detect (DCD) 15 ramsmit Clock 17 Receive Clock 20 Data erminal Ready (DR) 22 Ring Indicator (RI) his port operates as a DE and is configured for the following settings: 1-way in or 2-way operation Up to four SVCs Up to 64 kbps (synchronous) Packet size: 128 bytes Packet window: 2 n2 retry limit: 3 1 ACK timer: 20 seconds 3 time out: 3 seconds k window size: 2 Ethernet Port he SCU provides an SNMP interface via a standard Ethernet 10Base connector (J33) located on the backplane of the otal Access 1500 shelf. Connect and Logon to System here are two ways to connect and logon to the system: via the V100 craft/admin interface or a elnet session. otal Access shelf management and provisioning is facilitated by a series of intuitive menus that are accessible on a computer screen. hese menus are available through either a V100 terminal session or a elnet session. V100 erminal o connect either a terminal or a PC emulating a terminal to the craft port: 1. Set the parameters of the V100 terminal to: 9600 baud rate NOE he SCU craft port is defaulted to 9600 but has additional available baud rate of 38400. 8 data bits No parity 1 stop bit No flow control 2. When connecting a terminal to the craft port and the terminal has a parallel setting, disable it and use serial. When connecting a PC emulating a V100 terminal to the craft port, set the PC for direct connect (as opposed to dial-up connection). 3. When you are using the front craft port, use a serial cable with a male DB-9 connector on the otal Access end. 4. Plug the male end of the data cable into the otal Access shelf. Make connection to the V100 terminal as appropriate for your equipment. 5. o logon to the otal Access system, press any key. When password Authentication is enabled, the cursor will be placed at the Account Name field, waiting for an Account Name to be input. NOE he default account name is user and the default password is password. 6. At the Account Name field, input the Account Name for the otal Access shelf, then press ENER. he cursor will be placed at the Password field, waiting for a Password. 7. At the Password field, enter the Password for the otal Access System, and press ENER. 8. Upon entering the correct password, the otal Access main menu is presented on the screen. he otal Access menu system can now be accessed. 4 Section 61180008L1-5, Issue 2 61180008L1-5B

elnet he SCU will support four concurrent elnet sessions. elnet is supported via the Ethernet interface. o use elnet to communicate with the SCU, use the following steps: 1. Set the proper IP Address for the connection method of choice via the provisioning menu. For this procedure, refer to the following page of this practice. 2. Connect to the Ethernet Interface on the backplane of the otal Access 1500 shelf. 3. A successful elnet connection is established when the following appears on the screen: /* enter MENUS; to obtain menus (characters will not echo) */ OK 0 < 4. A L1 session may be activated at this time or to logon to the otal Access Menu System, enter MENUS;. If Password authentication is enabled, enter the Account Name for the otal Access shelf, and press ENER. he cursor will then be placed at the Password field, waiting for a password. 5. At the Password field, enter the Password for the otal Access System, and press ENER. 6. Upon entering the correct password, the otal Access main menu is presented on the screen. his signifies a successful logon. Provision the Ethernet Interface Settings If the otal Access 1500 shelf is to be connected to an Ethernet network for elnet, FP or SNMP Management, the IP Address, Subnet Mask, and Default Gateway must be set for the shelf to communicate with the network. o set the IP Address, Subnet Mask, and Gateway: 1. From the System Controller main menu, select option 5, Management Configuration, and press ENER. 2. From the Management Configuration menu, select option 1, IP Address, and press ENER. NOE he IP Address, Subnet Mask and Gateway are in the form XXX.XXX.XXX.XXX, with the XXX s representing 1, 2 or 3 digit decimal numbers from 0 to 255. 3. Enter a valid IP address, and press ENER. 4. From the Managemen Configuration menu, select option 2, IP Subnet Mask, and press ENER. 5. Enter a valid Subnet Mask, and press ENER. 6. From the Management Configuration menu, select option 3, IP Default Gateway, and press ENER. 7. Enter a valid Default Gateway, and press ENER. 8. From the Management Configuration menu, select option 4, elnet Port Number, and press ENER. 9. Enter the port to connect to when performing L1 over CP/IP. his is set to 2000 as a default. Menuing System he ADRAN otal Access SCU provides a menuing system for the otal Access shelf. All system-related menus are controlled by the SCU as well as some of the access modules menus. Other access modules have their own user menu structure supported by the module. Menu Structure he menu structure for the SCU is a layered menu tree. Each menu level consists of submenus and/or menu items. Some menu items are restricted to certain user accounts. he SCU supports Read-Write and Read-Only accounts. Each of these accounts may also be given est or Admin privileges. he Admin privileges allow the user to change all provisionable settings as well as network configuration settings that are not accessible to Read-Write and Read-Only accounts. Examples include SNMP provisioning, L1 provisioning, Date/ime settings, password administration, and software downloads. he Read-Write account allows the standard provisioning settings to be changed. he Read-Only account allows 61180008L1-5B Section 61180008L1-5, Issue 2 5

the user to view all provisioning settings, alarms, and statistics. An account with est privileges will also allow the account to perform tests. Figure 2 illustrates the menu structure of the SCU. Submenus are elements that move the user down to the next menu level. Menu items are elements which allow the user to make changes to the current SCU settings. here are two different types of menu items: read-only and read-write. A read-only menu item displays information that can not be changed, such as the status of the SCU. A read-write menu item displays information that when selected can be changed, such as the baud rate of the admin port. Intersystem Communication (RS-485) he ADRAN otal Access 1500 SCU supports communication with other otal Access 1500 systems over a shared, twisted-pair, half-duplex, RS-485 link. he SCU from each system is connected in parallel on this bus. Pin A should be connected to pin A, and Pin B should be connected to Pin B, so each shelf is in parallel. One SCU acts as the master controller and all others function as slaves. Physical access is attained by way of wire-wrap posts (P12) on the rear of the otal Access 1500 Shelf. Up to 32 shelves may be clustered together via the RS-485 bus. o set up RS-485 chaining, perform the following: 1. Give the first SCU in the chain a unique arget ID (ID). 2. Enable RS-485 Interface. 3. Set Interbank Communication Mode to Host. 4. Give the next SCU in the chain a unique arget ID (ID). 5. Enable RS-485 Interface. Setting the arget ID (ID) A unique arget ID (ID) must be given to each shelf of a chained RS-485 cluster. o set the arget ID (ID) in the otal Access 1500 SCU, perform the following: 1. Logon to the system. 2. From the otal Access 1500 main menu, select option 1, System Controller, and press ENER. 3. From the System Controller menu, select option 2, Provisioning, and press ENER. 4. From the Provisioning menu, select option 6, arget ID (ID), and press ENER. 5. Enter the appropriate arget ID and press ENER. NOE he arget ID (ID) may consist of up to 20 characters. he first character must be a letter. he remaining characters minus the last character may be alphanumeric or a hyphen. he last character must be alphanumeric. An example of a arget ID (ID) follows: HVLALEXD01 Where: HVL designates the city AL designates the state EX identifies the Central office or remote terminal D identifies the equipment type ("D" is administrative equipment) 01 identifies the piece of equipment of that type at the CO 6. Set Interbank Communication Mode to Client. Repeat steps 4-6 until up to 32 shelves have been chained. 6 Section 61180008L1-5, Issue 2 61180008L1-5B

1. Configuration 2. Provisioning 3. est 4. Alarms Unit Name CLEI Code Part Number Product Revision Software Revision MAC Address 1. Force LIU Failover 2. SCU Reset 5. Management Configuration 1. Date Enter Value 2. ime 3. erminal Auto-Logout 1. IP Address 2. IP Subnet Mask 3. IP Default Gateway 1. erminal Auto-Logout 2. Auto-Logout ime 1. None 4. Password Authentification 2. Local 5. Password 6. arget ID (ID) Enter New Password Enter Value 7. RS-485 Interface 8. Interbank Communication Mode 1. Client 2. Host 9. Y-Modem Application 10. est Access Mode 11. Craft Port Baud Rate 1. 9600 2. 38400 1. MA Mode 2. ML Mode Enter Value Enter Value (1...60) 1. Select Y-Modem Upload Destination 2. Start Y-Modem Upload 3. Modify Checksum 4. Compute Checksum and Store 5. Reset the Y-Modem Destination 1. Alarm Relay Mapping 2. Log ML Alarms 3. Ringer Alarms 4. AUX1 Alarm 5. AUX2 Alarm 6. RM Alarm 7. Alarm 8. SLC-96 Pwr/Misc Alm (CO Only) 9. PSU Configuration 10. LIU Configuration 1. SNMP Authentication raps 2. Read-Only Community Name 3. Read-Write Community Name 1. 1 Mapping 2. D4 Conventional 1. Dual PSU 2. Single PSU 1. SCU 2. Online LIU 1. Erase SCU 2. Cancel Enter New Checksum 2. Minor 3. Major 1. Dual LIU 2. Single LIU 4. ELNE Port Number Enter Value (1024.. 9999) 5. CP/IP Port Number 6. SNMP Configuration 4. System Contact Enter Value 5. System Name 6. System Location 6. Security Usernames (1-16) 1. User Name 2. Password 3. R/W 4. est 5. Admin Enter New User Name Enter New Password 7. SNMP rap Hosts rap Host 1-8 8. Re-Map Interface Indices 1. Read-Only 2. Read/Write 1. IP Address 2. Status Enter IP Address 1. Enabled 2. Disabled 6. Delete his User Figure 2. System Controller Menu ree 61180008L1-5B Section 61180008L1-5, Issue 2 7

Alarm Processing he SCU monitors the status of each line card and provides necessary alarm processing to determine the overall alarm state of the system. Alarm Outputs he SCU determines alarm states and reports these results via onboard alarm interfaces and through active user access channels. Each onboard alarm interface consists of Form-C relay contacts to provide Common (COM), Normally Open (NO), and Normally Closed (NC) functionality. Physical access to the relay contacts is attained by way of wire-wrap posts per alarm function. hese posts are located on the rear panel of the otal Access 1500 shelf. he following alarm outputs are supported: Alarm Major Audible Minor Audible Major Visual Minor Visual Wire-wrap Header MAJ-A MIN-A MAJ-V MIN-V he SCU provides front panel LEDs (See able 2) to indicate the status of the shelf and Alarm Cut () state. Alarm Inputs he SCU supports external alarm, status, or control inputs. Circuitry on the SCU accepts a -48V signal as an active state. Physical access to these inputs is attained by way of two wire-wrap posts per input function located on the rear panel of the otal Access 1500 shelf. he following alarm inputs are supported: Alarm Wire-wrap Header Auxiliary 1 AUX 1 Auxiliary 2 AUX 2 Alarm Cut AUX 3 Remote AUX 4 NOE he front panel mounted switch is used to cut off an alarm. Configuring Alarms o configure alarms the user will need to perform the following: 1. Logon to the system. 2. From the otal Access 1500 main menu, select option 1, System Controller, and press ENER. 3. From the System Controller menu, select option 4, Alarms, and press ENER. 4. Provision the alarms as desired. he following items may be configured: Alarm Relay Mapping allows the user to select 1 or D4 alarm relay mapping Log ML Alarms enables/disables the logging of ML alarms Ringer Alarms enables/disables ringer alarms AUX1 Alarm enables/disables AUX1 alarm input AUX2 Alarm enables/disables AUX2 alarm input RM Alarm enables/disables RM alarm input Primary Power Alarm enables/disables alarm condition associated with having primary power feed removed Secondary Power Alarm enables/disables alarm condition associated with having secondary power feed removed PSU Configuration choose single or dual PSU according to whether redundant equipment is installed in the otal Access 1500 chassis LIU Configuration choose single or dual LIU according to whether redundant equipment is installed in the otal Access 1500 chassis 8 Section 61180008L1-5, Issue 2 61180008L1-5B

4. MAINENANCE he SCU requires no routine maintenance to operate properly. Conduct tests and maintenance for the specific plug-ins in accordance with the recommendations and procedures prescribed by the manufacturer of each specific plug-in. ADRAN cautions against performing major repairs in the field. 5. PRODUC SPECIFICAIONS Product specifications for the ADRAN otal Access SCU are detailed in able 5. Repair services may be obtained by returning the defective unit to the ADRAN Customer Service RMA Department. Refer to Warranty and Customer Service section for more information. able 5. Detailed SCU Specifications General Front Panel: Craft Interface, DB-9 Connector (female) LEDs: MJR RM HS ML BSY Switches: Pushbutton Switch Ethernet: 10Base Shelf life for non-volatile memory storage: 10 years minimum Power Current Draw: 0.088 A maximum @ -48 V Operating Dimensions: Physical W eight: < 1 lb. emperature (Standard): Storage emperature: Environment 3.125 in. H x 1.54 in. W x 10.1 in. D -40ºC to +65º C -40ºC to +85º C Relative Heat Humidity: Dissipation: 95% maximum @ 50ºC, noncondensing 4.24 watts maximum Compliance UL 1950 NEBS Level 3 GR-1089-CORE Part Number otal Access 1500 System Controller Unit (SCU) Common 1180008L1 Module 61180008L1-5B Section 61180008L1-5, Issue 2 9

6. WARRANY AND CUSOMER SERVICE ADRAN will replace or repair this product within ten (10) years from the date of shipment if it does not meet its published specifications or fails while in service. Refer to ADRAN U.S. and Canada Carrier Networks Equipment Warranty, Document 60000087-10. Contact Customer and Product Service (CAPS) prior to returning equipment to ADRAN. For service, CAPS requests, or further information, contact one of the following numbers: ADRAN Sales Pricing/Availability (800) 827-0807 ADRAN echnical Support Pre-sales Applications/Post-sales echnical Assistance (800) 726-8663 Standard hours: Monday-Friday, 7 a.m. - 7 p.m. CS Emergency hours: 7 days/week, 24 hours/day ADRAN Repair/CAPS Return for Repair/Upgrade (256) 963-8722 Repair and Return Address ADRAN, Inc. CAPS Department 901 Explorer Boulevard Huntsville, Alabama 35806-2807 10 Section 61180008L1-5, Issue 2 61180008L1-5B