Manual. PDB + SBEC Module Voltage, Current, Capacity, Telemetry. No. S8474. Copyright Graupner/SJ GmbH

Similar documents
Voltage module +SBEC S8446

Alarm System SECURE AS 302

PHOTOVOLTAIC HEAT CONTROLER PVHC 2.01 USER MANUAL

Contents 1. Helpline No. UK/ North Ireland Rep. Ireland , Web Support Model Number: MD

WIRELESS DIGITAL DOOR

IFS Fiber Module Installation & Operation Instructions

Operating instructions for the radio heat detector GS412

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

FAZ 3000-DCF DCF module

Weather Station Wetterstation

Thermo-/Hygrometer with Mould Alert Model WS 1500 Operating Manual

Health & Safety and Installation guide

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

GB Operating instructions

Instruction manual EN

Silent TS. Nr / Ideas for dental technology / A. Made in Germany

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

Rechargeable Trimmer. Rechargeable Trimmer Instructions

User and maintenance manual

Juicer User Manual BKK 2144 BKK 2144 Y

IFS Fiber Module Installation & Operation Instructions

VACUUM CLEANER VCH 9530

MANUAL Oil Level Sensor

AZSG10000/AZSG10005/AZSG10010 ABUS Wired Outdoor Siren

80 CHANNELS WIRELESS RECEIVER WITH LCD DISPLAY M1.1.1-Hx.x-F1.1-ENG [AN] [SPV] MADE IN ITALY INSTALLATION AND USE MANUAL

Robot VR 101. C73_2016_07 Robot VR 101_manual_intl_06062 Version: October 10, 2016 / TSU

HR 601 C A AUS. ENGLISH Instructions for use Page 2

Instruction manual. Aluminium radiator with ceramic heart. Smart Electric Heaters

Electronic Crimping Tools REF Operation Guide

VISION H. Instruction manual

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

TC100 OPERATING MANUAL THERMOHYGROMETER TRT-BA-TC100-TC-001-EN

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

Remote alarm unit Art. Nr.:

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A)

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

IFS Fiber Module Installation & Operation Instructions

PAGE METEO CENTER USER MANUAL

Installation manual extra-low-voltage socket outlets for panel- and surface-mounting

testo 316-EX gas leak detector Instruction manual

External Wireless Sounder

SAFETY AND OPERATING MANUAL

Instruction manual 7FAS Avdel Deutschland GmbH +49 (0) (0)

L / -014L / -015L

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Installation manual plugs and connectors QUICK-CONNECT (63 A)

Instructions for use

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets QUICK-CONNECT (63 A)

Operating instructions

External Wireless Sounder

Clean Base Automatic Dirt Disposal. For Roomba i Series Robot Vacuums. Owner s Guide

10 Year Smoke Detector and Siren

Progress plus Instruction manual

Remote alarm case VENTIremote alarm 10 m WM VENTIremote alarm 30 m WM Device description and instructions for use

DSD-080 SEISMIC SECURITY PANEL DESCRIPTION FEATURES. DSD-080 User Manual

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

Glue Gun 25W TTB580HTL. Barcode: WARNING: Read the instructions before using the product!

6 Sheet Strip-Cut Shredder for Home/Office

Operating Manual Bathroom Balance

VT1101M VT1102M IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

Electronic timeswitch

METAL CERAMIC FAN HEATER

Built in Electric Ceramic Hob. Instruction Manual

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

User s Guide Wireless Doorbell for IWATCHALARM (Add-On) Model: SM-105DB

With this symbol Gavita declares that this product complies with legal European requirements.

Control box FSTronic DES-FS

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

DIGITAL BODY WEIGHT SCALES PS 4110

SCHMIDT LED Measured Value Display MD Instructions for Use

GB User and maintenance manual

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

Vacuum cleaner Instruction manual

M-488A Cleaning Robot Owner s Manual

Electronic Crimping Tools

ST 53.1 User s manual

VACUUM CLEANER VCC 4350 A ENGLISH

Computer Room Guard Model VM Manual and Installation Instructions

Malem MO7 Wireless Alarm + Record Wetness Sensor and Toilet Trainer

OPERATING INSTRUCTIONS

DC 60 & DM 60 displays

IMPORTANT SAFETY INFORMATION

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user.

Operator s manual. Battery charger C 48/ en / 03

Sprint Mag XS. 15x15 cm OPERATOR S MANUAL.

75 Sheet Micro-Cut Shredder With CD/DVD Slot

Beacon 800 Gas Monitor Operator s Manual

User s Guide Home Automation Wall Socket for IWATCHALARM (Add-On) Model: SM-001SK

600 Series Owner s Guide

User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen 2 Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi

SOOTHING COOL MIST AROMA DIFFUSER

MV 2. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

English. Doro CareIP Mobile. User Guide

Clam Basic. 28x38 cm 38x38 cm 40x50 cm OPERATOR S MANUAL.

Pipo Communications. Model ST-888. DTMF ANI/ENI Display Decoder

USER GUIDE. Last update on MARCH 19,

Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual

Transcription:

EN Manual PDB + SBEC Module Voltage, Current, Capacity, Telemetry No. S8474 Copyright Graupner/SJ GmbH

2 / 2

Index Introduction...4 Service Centre...4 Intended use...5 Package content...5 Technical Data...5 Declaration of conformity...5 Symbols explication...6 Safety notes...6 Montage and connections...7 Programming the alarm threshold...7 Programming the User Setup...9 Ext. Switch...10 Indication in the transmitter telemetry display...10 Meaning of the red LED signals...10 Notes on environmental protection...11 Care and maintenance...11 Warranty certificate...11 3 / 12

Introduction Thank you very much for purchasing the Graupner PDB + SBEC Module. This PDB + SBEC Module is extremely versatile. Read this manual carefully to achieve the best results with your PDB + SBEC Module and first of all to safely control your models. If you experience any trouble during operation, take the instructions to help or ask your dealer or Graupner Service Centre. Due to technical changes, the information may be changed in this manual without prior notice. Be always updated by checking periodically on our website, www.graupner.de to be always uptodate with the products and firmwares. This product complies with national and European legal requirements. To maintain this condition and to ensure safe operation, you must read and follow this user manual and the safety notes before using the product! NOTICE This manual is part of that product. It contains important information concerning operation and handling. Keep these instructions for future reference and give it to third person in case you gave the product. Service Centre Graupner Central Service Graupner/SJ GmbH Henriettenstrasse 96 D-73230 Kirchheim / Teck Graupner USA OPENHHBBY LLC 3245 University Ave Suite 1520 San Diego, CA 92104 Servicehotline (+49) (0)7021/722-130 Monday - Thursday 9:15 am - 4:00 pm Friday 9:15 am - 1:00 pm Website: www.graupnerusa.com (+1) 855-572-4746 Email:service@openhobby.com Graupner in Internet For the service centers outside Germany please refer to our web site www.graupner.de 4 / 12

Intended use The PDB + SBEC Module is used to easily monitor the LiXX battery through HoTT telemetry and as BEC power supply for receiver. The battery will be connected to the module through the battery connection cable. The battery is permanently monitored and through the programmable acoustic alarm the user can be informed in case the voltage is lower than the programmed threshold and about capacity and current consumption. Other uses are not allowed. For any improper use no warranty or liability is accepted. Read through this entire manual before you attempt to install or use the PDB + SBEC Module. Graupner/SJ constantly works on the development of all products; we reserve the right to change the item, its technology and equipment. Target group The product is not a toy. It is not suitable for children under 14 years. The installation and operation of the PDB + SBEC Module must be performed by experienced modellers. If you do not have sufficient knowledge about dealing with radio-controlled models, please contact an experienced modeller or a model club. Package content PDB + SBEC Module Manual Technical Data Operational voltage - 7,4 to 22,2 V Max. current - 60 A BEC voltage - 4,5 to 8 V Dimensions - 35 x 35 x 7 mm Weight - 25 grams Declaration of conformity S8474 PDB + SBEC Graupner/SJ declares that the product is conform to EU norms. EMC 2004/108/EC: EN 61000-6-3: 2007+A1:2011 EN 61000-6-1:2007 5 / 12

Symbols explication! Always observe the information indicated by this warning sign. Particularly those which are additionally marked with the words CAUTION or WARNING. The signal word WARNING indicates the potential for serious injury, the signal word CAUTION indicates possibility of lighter injuries. The signal words Note and Attention indicate potential damages to objects. Safety notes! General These safety instructions are intended not only to protect the product, but also for your own and other people s safety. Therefore please read this section very carefully before using the product! Do not carelessly leave the packaging material lying around, since it might become a dangerous toy for children. Persons, including children, with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, or not capable to use safely the PDB + SBEC Module must not use the PDB + SBEC Module without supervision or instruction by a responsible person. The PDB + SBEC Module should never be in touch with water. Protect the module from dust, dirty, humidity and other small parts. Avoid abnormal mechanical stress. Risk of fire! Do not connect the PDB + SBEC Module with reversed polarity. Use polarity-safe plug-in systems. Avoid short-circuits. Risk of fire! Follow the safety instructions included with the batteries. Use the PDB + SBEC Module only within the indicated voltage range, sirk of fire! The PDB + SBEC Module is conceived to be used only with Lithium batteries, the PDB + SBEC Module should not be used with other types of batteries, like NiMH or NiCd. Risk of fire! Changes and modification on the module are not allowed because of safety and conformity (CE) reasons For all questions that are not answered in this manual, please contact our Customer Service. 6 / 12

T Montage and connections Install the PDB + SBEC Module in a proper place inside the model where it is protected from vibrations. Connect the 3 poles cable to the telemetry port of the receiver. The connectors are reverse polarity protected: note the small chamfers on the sides. Never use force the connectors should engage easily. The socket is labeled accordingly: Brown cable (-), red cable (+) and orange cable (T). The battery cable with the XT-60 connector is connected to the battery. (Red = + / black = -) The update port allows the receiver update even with connected module. To update the PDB + SBEC Module please read the instruction before you use the "Firmware_upgrade_studio on www.graupner.de. Moreover the BEC voltage can be used to power for example an FPV camera. Update port Battery 2-6 S Receiver ESC ESC PDB + SBEC ESC ESC The small 3 poles socket is provided for switch functions. See paragraph Programming the user setup Programming the alarm threshold The alarm thresholds are displayed in the telemetry menu of the transmitter. (Please read the manual of your transmitter how to view the telemetry menu and how to navigate it) The first page of the PDB + SBEC Module in the telemetry menu is only a display page. In the next pages the alarm thresholds can be set. It is possible to set up to 3 alarm thresholds for minimum battery voltage. Min Voltage: The first alarm threshold can be used for the normal minimum voltage, e. g. to allow a safe return flight. Sensor 1: The second aarm threshold can be set a little lower than the first one. So you can for example set a "coming home function". Sensor 2: The third threshold is normally set a little lower e. g. to set a self landing function before the battery is completely empty. 7 / 12

The following parameters can be set separately for all displays: Warning Time: here you can set for each display if and how long the alarm should be active for a specific value. Repeat Time: here you can set how often an alarm should be active when a specific value is reached. Page 1 Page 2 Page 3 Page 4 Signal Tone: sets the signal tone melody. The warning sounds are combined with the warnings on the display and the voice output. Therefore, they may not be changed. Save Sensor: yes/no After every setting in the pages "Page 1-5" the data must be transferred to the PDB + SBEC Module. Select "yes" and push "Enter". If you do not proceed as described, the new data will not be saved. Factory set A factory reset will be done if you select "yes" and push "Enter". Min Power Voltage Here you can set the alarm threshold for minimum voltage. The alarm threshold can be set between 0 and 25.0 V in steps of 0,1 V. Factory setting: 11.0 V, Signal Tone: P Sensor 1 Voltage Here you can set the first alarm threshold for voltage. The alarm threshold can be set between 0 and 25.0 V in steps of 0,1 V. Factory setting: 10.8 V, Signal Tone: R Sensor 2 Voltage Here you can set a second alarm threshold for voltage. The alarm threshold can be set between 0 and 25.0 V in steps of 0,1 V. Factory setting: 10.5 V, Signal Tone: S 8 / 12

Page 5 Page 6 Page 7 Max Power Voltage Here you can set the alarm threshold for maximum voltage. The alarm threshold can be set between 0 and 25.0 V in steps of 0,1 V. Factory setting: 17.5 V, Signal Tone: X Max Current Here you can set the first alarm threshold for maximum current. The alarm threshold can be set between 0 and 150 A in steps of 1 A. Factory setting: 40 A, Signal Tone: W Max used Capacity Here you can set the alarm threshold for maximum consumed capacity. The alarm threshold can be set between 0 and 30000 ma in steps of 10 ma. Factory setting: 2000 ma, Signal Tone: V Programming the User Setup Page 1 Page 2 In the "User Setup the BEC voltage produced by the PDB + SBEC Module is set. Save Sensor: yes/no After every setting in the page "Page 2" the data must be transferred to the PDB + SBEC Module. Select "yes" and push "Enter". If you do not proceed as described, the new data will not be saved. Factory set A factory reset will be done if you select "yes" and push "Enter". All the values will be reset to the factory settings. BEC Voltage Here you set the BEC voltage. The voltage can be set between 4,5 and 8 V. In the following lines the BEC voltage will be shown. 9 / 12

Ext. Switch Here you can set the 3 switch outputs. The value is settable between high and low. low indicates that the output is switched off (0 V) high indicates that the output is switched on (3 V) Factory setting: low Use example: to switch the video channel on the transmitter the switch outputs can be connected in parallel to the dip switch. Then low means status ON in the dip switch. In this case the dip switch must be set to OFF. Indication in the transmitter telemetry display Select the telemetry display GENERAL. The following displays will appear, at right the actual cell voltage or the total voltage are alternatively shown. Under BAT1 and SENSOR 1 will appear the actual total voltage, under BAT2 and SENSOR 2 will appear the minimum cell voltage since the battery has been connected. SENSOR 1 12.1V 0 C RX S QUA: 100% RX S EMPFÄNGER ST : 100% RX dbm: GENERAL 33dBm TX dbm: 33dBm ELECT. AIR V PACK: 10ms VARIO RX SPG.:4.8 GPS TMP CH OUTPUT TYPE:ONCE AKK1 L KRAF V 12.1V T1 0 C AKK2 3.9V T2 0 C ZELL.V 1:4.00 2:4.10 3:4.00 4:0.00 5:0.00 6:0.00 0 12.1V 0.0A 0mAh 0ml SENSOR 2 3.9V 0 C AKK1 12.1V L KRAF V T1 0 C AKK2 3.9V T2 0 C HÖHE 0m 0m1 0m3 SPANN. 12.1V 0.0A 0 Meaning of the red LED signals BEC VOLTAGE RED LED 4.5V 1x blink 5.0V 2x blinks 5.5V 3x blinks 6.0V 4x blinks 6.5V 5x blinks 7.0V 6x blinks 7.5V 7x blinks 8.0V LED on 10 / 12

Notes on environmental protection Disposal notes This symbol on the product, user manual or packaging indicates that this product must not be disposed of with other household waste at the end of its life. It must be handed over to the applicable collection point for the recycling of electrical and electronic equipment. The materials are recyclable as marked. By recycling, material reusing or other forms of scrap usage you are making an important contribution to environmental protection. Batteries and accumulators must be removed from the device and disposed of at an appropriate collection point. Please inquire if necessary from the local authority for the appropriate disposal site. Care and maintenance Warranty certificate P Notes on care The product does not need any maintenance, it works so as it is without any special care. In your own interests protect it from dust, dirt and moisture. Clean the product only with a dry cloth (do not use detergent!) lightly rub. The Graupner, Henriettenstrassee 96, 73230 Kirchheim/Teck grants from the date of purchase of this product for a period of 24 months. The warranty applies only to the material or operational defects already existing when you purchased the item. Damage due to wear, overloading, incorrect accessories or improper handling are excluded from the guarantee. The legal rights and claims are not affected by this guarantee. Please check exactly defects before a claim or send the product, because we have to ask you to pay shipping costs if the item is free from defects. The present construction or user manual is for informational purposes only and may be changed without prior notice. The current version can be found on the Internet at www.graupner.de on the relevant product page. In addition, the company Graupner has no responsibility or liability for any errors or inaccuracies that may appear in construction or operation manuals. No liability can be accepted for printing errors. 11 / 12