Ditec VALOR R Sliding door installed in escape routes (Original intructions)

Similar documents
Ditec DOR Folding doors operator

Ditec DAS107PLUS User Manual IP2270EN.

Ditec QIK80EH Electromechanical barrier (Translation of the original instructions)

GLOBE. Installation and maintenance manual for automations for sectional overhead doors and spring balanced up-and-over doors. (Original instructions)

Motorised swing doors User manual (translation of the original instructions) IP2225EN

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

FEC400 Series. Installation Manual

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

Refrigerator KE T

Installer: (Name, address, telephone number)

Control panel installation manual for automations with one or two 24V motors (Translation of the original instructions) 24V~ ESC

Installer: (Name, address, telephone)

Installer: (Name, address, telephone number)

REPAIR INSTRUCTIONS. TUMBLE DRYER Vented WTA34.. / WTA35..

OSA 3. Level alarm for oil separator. Afriso Ema AB. Kilvägen 2 SE Arlöv Sweden T +46-(0) F +46-(0)

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

Box. Automation for counterweight up-and-over doors. Advanced entrance technology ENG

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE

Installer manual AG-WL10

1F98EZ-1421, Easy Install

Installer: (Name, address, telephone)

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

AUTOMATIC VACUUM UNIT

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

Installation, Operating and Maintenance Manual

MODEL B2 INSTALLATION MANUAL

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

ER52 - Evaporator Controller

ORION Mini-Rep INSTALLATION MANUAL

Installer: (Name, address, telephone)

CONTROL PANELS for 2 Q2P series ELECTRIC PUMPS

WIRING DIAGRAM AND INSTRUCTIONS

ELECTRONIC PANEL LRX 2035 ALARM

STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL

ALT 4 ALT 6 ALT 4K ALT 6K

CONTROL PANEL. RIELLOtech PRIME ACS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

ADE Gen4. Speech Dialler Engineering Information. Description. Features

Installer: (Name, address, telephone number)

INSTRUCTION MANUAL DAAB AUTOMATIC CONTROL UNIT EP104. Instruction manual version 1 for Software version 4.05

Conventional Fire Alarm System 2014 V1.2

ROOM THERMOSTATS KNX BASIC DOCUMENTATION

Swing Door Operator EM EMSW

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

IMPORTANT SAFETY INFORMATION

Instructions for Use

Version 1.03 January-2002 USER S MANUAL

Instruction manual. W440 AIS Sart Sniffer

Operating Manual RCM420

Fire Command Keypad. XR5 User s Guide

Updated: 17/03/2010 ELECTROLUX. CAREL ir33. Quick reference Handbook. Ver. 1.1 Eng. Pag.1/12

Control Panel User Guide

Instructions for Use

SensaGuard TM Integrated Latch Installation Instructions

Installation, Operating and Servicing Instructions. Opus 800 Electric Cook & Hold Salamander OE8306

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

CD30 Codoor. Instruction Manual

ST1. Mod. USE AND MAINTENANCE MANUAL

ELECTRONIC AIR CONDITIONING CONTROL

TS700. Intruder Alarm Control Panel ENT 0 ESC

SACE PR021/K SIGNALLING UNIT

Salamander User Guide

OPERATING INSTRUCTIONS

Operating and maintenance instructions for hobs

Operation and Maintenance Manual

Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN)

Magnetically Coded Non-contact Switch (MC2)

CSP-204 CSP-208 CSP-104 CSP-108

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

Intelligent Security & Fire Ltd

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

Swedish Technical Approval SC

EasyTronic III MANUAL SERVICE

CTT8 TEMPERATURE MONITOR DEVICE

Dexxo Pro io. Installation manual Installatiegids Instrukcja montażu. somfy.com. Situo io Situo io A/M Situo io mobile.

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

IE Instructions and warning book CRONO 7. Weekly digital chronothermostat

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

AGC 200 Advanced Gen-set Controller OPERATOR S MANUAL

MO n : 12JMC rév A

Eclipse MC240. Double & Single Gate Controller with Eclipse Operating System (EOS) 3rd Edition. MC240 for Double and Single Gates.

AQUAMAC MODELS

Installer: (Name, address, telephone)

Silent Alert Fire Safe System

USE AND INSTALLATION HANDBOOK

20 Light Remote Annunciator

Dexxo Pro RTS

INSTALLATION AND OPERATING INSTRUCTIONS KLIMA

Alarms Manual. ver.1 rev.06/'07. Enclosures to Service Manuals of: McbNET Digital TM Magnum400 TM MiniMagnum400 TM. 6) Speeder One

AIS750 Series Alarm Annunciator

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Instructions for the BASIC BCRW Fan, Sizes General

Room thermostats with LCD for wall mounting

MOTOR FOR SLIDING GATES SERIE GR8 220V

Fire Control Panel FS5100

Transcription:

Ditec VALOR R Sliding door installed in escape routes (Original intructions) IP2089 EN Technical manual www.entrematic.com

INDEX Subject Page 1. General safety precautions 3 2. Declaration of incorporation of partly completed machinery 3 2.1 Machinery directive 3 Technical data 4 6 4. Standard installation 5 6 6 7 8 9 11 12 12 Electrical connections with 13 Electrical connections with 14 Electrical connections 15 15 17 17 17 Signals 18 18 18 19 maintenance program 20 21 10. User instructions 24 26 All rights reserved purposes. 2

1. GENERAL SAFETY PRECAUTIONS This installation manual is intended for professionally competent personnel only. - - 2. DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY 10-11-2010 (Managing Director) 2.1 Machinery directive - Directive. 3

3. TECHNICAL DATA VALOR LR VALOR NR VALOR TR Power supply Intermittence Service life * (reinforced wheels) (reinforced wheels) Temperature Degree of protection IP20 IP20 IP20 * 3.1 Applications Service life: 6 Applications: CONTINUOUS data. each single installation. 4

4. STANDARD INSTALLATION 9 5 4 2 1 3 9 3x1,5 mm² A 6 8 7 REF. CODE DESCRIPTION 1 Drive unit 2 Power supply unit 4 or or or Release handle or 8 MD1** Display module (included) 9 Power supply i NOTE: The given operating and performance features can only be guaranteed with the use of DITEC accessories and safety devices. 5

5. INSTALLATION OF THE AUTOMATION 5.1 Box VALOR LR-NR fastening 175 +/- 8 +/- 6 28 90 38 145 27 80 70 max H 0KP515AB 10 HM = H + 18 to the measurements in the related manuals. WARNING: The fastening of the box to the wall must be suitable in order to sustain the weight of the door wings. 6

5.2 Box VALOR TR fastening 255 90 38 +/- 8 145 27 +/- 6 +/- 6 28 160 70 max 70 max 12 H HM=H+16 KPAM45 KPAM45 to the measurements in the related manuals. WARNING: The fastening of the box to the wall must be suitable in order to sustain the weight of the door wings. 7

5.3 VALOR LR-NR wings installation and adjustment max 0,5 mm d c d b a b VALOR LR-NR 2 150 150 150 150 OPEN OPEN LM LM VALOR LR-NR 1 DX 240 OPEN 150 LM VALOR LR-NR SX 150 OPEN 240 on the guide. WARNING: Leave a gap of at least 10 mm between the glass door wings when closed to avoid contact of the glass. LM 8

5.4 VALOR TR wings installation and adjustment max 0,5 mm max 0,5 mm c d b a b g f e f g 3 mm f e on the guide. - Place the door in the closed position. 9

VALORTR 2+2 150 100 100 150 150 150 150 150 S S OPEN OPEN OPEN OPEN LM LM LM LM d e f f e d VALORTR 1+1 DX 240 150 100 OPEN S OPEN 150 LM LM f e d VALORTR 1+1 SX 150 100 150 240 OPEN S OPEN LM LM d e f 10

3.5 Floor guide installation enter the doorway. 10 22 10 HM min 21 max 40 50 10-12 25 5 10 HVM 50 40 12 19 12 50 5 HM 42 42 11

5.6 Belt adjustment - WARNING: incorrect adjustment impairs the correct functioning of the automation. b a LT<2600 = 22 mm LT 2600 = 20 mm 5.7 Lock device installation Place the door wing in the closure position. VALOR LR VALOR NR c b VALOR TR c b a a 12

ELECTRICAL CONNECTION WITH COMER SELECTOR NC NO C CLOSING SAFETY OPENING SAFETY OPENING SAFETY OPEN ON 1 2 3 4 0 1 R+ R- 8A 41 0 1 3B 8B 41 0 1 6A 6B 41 1 2 A B 9 27 29 INTERNAL SENSOR REMOTE 0 1 21 22 POWER ALARM IN SA EXTERNAL SENSOR OPEN SAFETY GENERAL PURPOSE ROTARY FUNCTION SELECTOR MOT2 + - 1 EO 1 AO 1 KO KC 1 G1 G2 + BAT +AUX BUZZER KEY CLOSE KEY OPEN AUXILIARY OPENING EMERGENCY OPENING MOTOR POWER SUPPLY UNIT 230 V~ F1=F1,6A ENC MOT + - POWER BAT AUX + - 1 S1 S2 LN INTERNAL SENSOR PASAM24T EXTERNAL SENSOR DO NOT USE VALLOKB BATTERY red - + + - F10A red blue blue DO NOT USE DO NOT USE LK + - DO NOT USE red grey grey 0 1 R+ R- 1 8 41 0 24V green brown yellow white pink grey red blue COMER 1 2 3 4 5 6 X MD1 X X X FERRITE (1 loop) DO NOT USE 1 OP KEY 2 1 2I 1I P PI 1R MR POWER RESET DMCS jack 0 1 2122 13

DO NOT USE ELECTRICAL CONNECTION WITH COMKR SELECTOR DMCS jack CLOSING SAFETY OPENING SAFETY OPENING SAFETY OPEN ON 1 2 3 4 0 1 R+ R- 8A 41 0 1 3B 8B 41 0 1 6A 6B 41 1 2 A B 9 27 29 INTERNAL SENSOR REMOTE 0 1 21 22 POWER ALARM IN SA EXTERNAL SENSOR OPEN SAFETY GENERAL PURPOSE ROTARY FUNCTION SELECTOR MOT2 + - 1 EO 1 AO 1 KO KC 1 G1 G2 + BAT +AUX KEY CLOSE KEY OPEN AUXILIARY OPENING EMERGENCY OPENING MOTOR 230 V~ F1=F1,6A ENC MOT + - POWER BAT AUX + - 1 S1 S2 LN INTERNAL SENSOR PASAM24T EXTERNAL SENSOR COMKR BATTERY red - + + - F10A red blue blue DO NOT USE DO NOT USE LK + - DO NOT USE red grey grey 0 1 R+ R- 1 8A 41 0 24V POWER RESET NC NO C 1 2 A B 9 27 28 29 green brown yellow white pink grey red blue DO NOT USE MD1 X VALLOKB BUZZER POWER SUPPLY UNIT X X X FERRITE (1 loop) 14

INTERNAL SENSOR EXTERNAL SENSOR 6. ELECTRICAL CONNECTION Installation, electrical connections and adjustments must be performed in accordance with Good Working Methods and in compliance with applicable regulations. The safety devices must protect any areas where the risk exists of being crushed, cut or gragged, or where there are any other risks generated by the motorised door or gate. Before making power connections, make sure the plate details correspond to those of the power mains. Fit an omnipolar disconnection switch with a contact opening gap of at least 3 mm. Make sure an adequate residual current circuit breaker and overcurrent cutout are tted upstream of the electrical system. Use a 3x1.5 mm FROR 450/750V type electric cable and connect to the terminals L (brown), N (blue), T (yellow/green) in the automation. Secure the cable using tie-wraps or cable clamps that are not supplied. Make sure there are no sharp edges that may damage the power supply cable. Connection to the mains power supply, in the section outside the automation, is made with independent channels and separated from the connections to the control and safety devices. During installation, maintenance and repair, interrupt the power supply before opening the lid to access the electrical parts. To handle electronic parts, wear earthed antistatic conductive bracelets. The motor manufacturer declines all responsibility in the event of component parts being tted that are not compatible with the safe an correct operation. WARNING: make a jumper on all N.C. contacts if not in use. The terminals with the same number are equal. 6.1 Commands Command Function Description R+ R- 41 8A 1 3B 41 8B NOTE: terminals R+/R- are a current input. The opening of the contact during the closure manoeuvre causes the movement to invert (opening). The opening manoeuvre starts when the contact is closed. The opening of the contact during the closure manoeuvre causes the movement to invert (opening). OPEN SAFETY 41 6A 41 6B 1 EO 1 AO NOTE: advanced command management is available with the MD1 display module. The opening of the contact activates the emergency opening manoeuvre. This command is active under all conditions (also in NIGHT mode) and prevails over all other commands. - NOTE: This command can be linked to an emergency button. The closing of the command activates the opening manoeuvre. NOTE: This control can be combined with a magnetic board reader for automated teller machines access in case door is set to NIGHT-TIME CLOSURE mode. 15

1 KO The closing of the contact activates the opening manoeuvre. MD1 display module). NOTE: this command can be associated with a key to allow to go out in the evening or to come back in the morning from the shop door set to NIGHT mode. 1 KC The closing of the contact activates the closing manoeuvre. - NOTE: this command can be associated with a key to allow to go out in the evening or to come back in the morning from the shop door set to NIGHT mode. 1 G1 G2 1 S1 OPEN SETTINGS RESET for 2 seconds within 4 seconds. The SETTINGS RESET annuls all the remote software settings NOTE: We recommend carrying out the SETTING RESET during starting (see section 7), or whenever the COMER selector is replaced with COMKR selector. 16

6.2 Outputs and accessories Output Value - Accessory Description Accessories power supply. output. 0 1 NOTE: the maximum absorption of 0.5 A corresponds to the sum of all terminals 1. - 0 1 21 22 NOTE: use a data transmission type screened cable. 1 2 A B 9 27 29 +B-B 6.3 Dip-switch NOTE: connect terminals 21-22- (REMOTE) to jack DMCS socket present in COMKR selector, using a data transmission type screened cable. Storage module (BIXMR2). the MD1 display module. Motor-encoder connection. AL2 Feeder Connection, Anti-panic battery kit.mation will carry out an opening operation at low speed. To charge WARNING: connect batteries, as explained on pages 13 and 14. VALLOKB bistable blocking device. WARNING: connect block auxiliary coil to AUX terminals, as explained on pages 13 and 14. Description OFF ON DIP1 Block type DIP2 FUTURE USE DIP3 Door weight DIP4 FUTURE USE 6.4 Adjustment 17

6.5 Signals LED ON Flashing POWER ALARM 24 V= power supply. IN SA Safety test failure. BUZZER Event Effect Escape route test 1 acoustic signal every second 6.6 ESCAPE ROUTE SENSORS WARNING: on sliding doors used in escape routes, the opening on the exit direction shall be controlled by an autocontrolled safety sensor model PASAM24T (or equivalent). 6.7 PASAT3 0 1 R+ R- INTERNAL SENSOR A B 24V - + 1 2 A 3 4 5 6 24V - + 1 2 B 3 4 5 6 RED GREEN BLUE WHITE BROWN ORANGE RED GREEN BLUE WHITE BROWN ORANGE 0 1 6A 6B 41 OPEN SAFETY 18

7. STARTING - ATTENTION: the control panel performs an automatic POWER RESET on each start and the first opening or closing manoeuvre is performed at low speed allowing the automatic self-learning of the stop positions (acquisition); - WARNING: pass the accessory cable through the ferrite (1 turn), as shown on page 13 or 14. - i NOTE: in case of alarms, follow the instructions given in section 9. 19

8. ORDINARY MAINTENANCE SCHEDULE Power off 230 V~ and batteries: carriages run). NOTE1: Use original spare parts only for repairing or replacing products. If control panel EL21 is replaced, the last used con guration can be restored using the SF RL function of MD1 display module, or a con guration from the BIXMR2 storage module can be recalled using SF RC function of MD1 display module, if previously saved. NOTE2: In case rmware needs updating, connect DMCS device to jack DMCS socket present on the COMER or COMKR function selector. Once these operations are completed, disconnect the DMCS device and make a POWER RESET, as speci ed in the instructions for use on page 26. 20

9. TROUBLESHOOTING The MD1 display module displays the following alarms that have the priority on all the other displayed messages. The following alarms cause door immediate opening. NOTE: where indicated, perform an ALARM CLEAR to restore door operation. If it does not work, perform a POWER RESET as speci ed in the INSTRUCTIONS FOR USE on page 26. ALARM POWER DISPLAY INTERVENTION DESCRIPTION RESET sensor. TEAR OFF AND DELIVER TO USER sensor. sensor. installed on terminal 8. sensor. sensor. installed on terminal 8B. sensor. nal 41 B0 - Batteries almost run down E0 - Encoder failure E2 - Motor or encoder leads reversal Replace the encoder. Encoder failure Replace encoder. tection to test performance mand activation lure 21

DISPLAY POWER RESET IG - Motor drive fault IH - Motor currents fault electronic failure TEAR OFF AND DELIVER TO USER M4 - Motor short circuit MB - No motor P0 - No mains voltage. ALARM INTERVENTION DESCRIPTION tion plete - tor. error S4 - Mechanical selector ror or failure Replace selector. connection failure - 22

DISPLAY ALARM INTERVENTION DESCRIPTION permanently closed POWER RESET T0 - Motor test failure T1 - Motor 2 test failure DISPLAY ALARM DESCRIPTION detection INTERVENTION tions onto door wings. POWER RESET TEAR OFF AND DELIVER TO USER sion failure Door is too long. M9 - Door dimension error - Door too short. rect. Proceed with the routine maintenance intervention. intervention. 23

10. USER INSTRUCTIONS ON OFF 10.1 General safety precautions - Do not lean against or hang on to the door when it is moving. - - personnel. TEAR OFF AND DELIVER TO USER 24

10.2 Manual release instructions open position. WARNING: carry out the door wing blocking and release with the motor switched off. TEAR OFF AND DELIVER TO USER 10.3 Escape route test starting from the last test carried out. NOTE: escape route test is carried out on the following occasions: upon every start (see section 7), with the POWER RESET, and when you quit the NIGHT-TIME CLOSURE mode after at least 4 hours. 25

11. FUNCTION SELECTOR USER INSTRUCTION FUNCTION SELECTOR COMER COMKR 4 The door opens and remains open. 1 2 3 6 WARNING: MD1 display module displays S3 alarm. Door closes after a 10 s operation to allow authorised door management autho- NOTE: with the COMER selector, operation can be extended to 60 s, while with 5 COMKR selector operation can be set from MD1 display module. WARNING: door operation as escape route is disabled. WARNING: in case of alarm (see section 9), when envisaged, a POWER RESET shall be performed to restore door operation. WARNING: in case of alarm (see section 9), when envisaged, a POWER RESET shall be performed to restore door operation. NOTE: The DMCS jack can be accessed by removing the function selector switch cover. 1 4 5 6 1 2 4 5 6 DMCS jack 2 3 POWER RESET 3 DMCS jack POWER RESET TEAR OFF AND DELIVER TO USER WARNING: during door operation as escape route, COMER or COMKR selector shall be disabled, key shall be removed, and the set operating mode shall be TWO-WAY, ONE-WAY or OPEN DOOR. Any other setting of the selector may affect escape route operation, and can be selected by authorised staff only, when the use conditions allow it. It allows selecting the desired function. WARNING: after having selected the desired function, disable selector in order not to display the S8 alarm on the MD1 display module. 26

SYMBOL MEANING DESCRIPTION The door opens and remains open. ENABLING DOOR OPERATION DISABLING DOOR OPERATION ALARM RESET 27

Entrematic Group AB Lodjursgatan 10 SE-261 44, Landskrona Sweden www.entrematic.com IP2089EN - 2011-04-08