The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen *

Similar documents
International Forum on Energy, Environment Science and Materials (IFEESM 2015)

Displacement Ventilation

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

Numerical Simulation of Ventilation Efficiency in Commercial Kitchen

The Performance of Diffuse Ceiling Inlet and other Room Air Distribution Systems Nielsen, Peter Vilhelm; Jakubowska, Ewa

MODELLING AND SIMULATION OF A ROOM WITH A RADIANT COOLING CEILING. Technicka 4, Prague 6, Czech Republic

Space Air Diffusion II

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Thermal comfort investigation on a naturally ventilated two- storey residential house in Malaysia

Numerical Simulation of Thermal Comfort Degree in Radiant Floor Cooling Room. Architecture, Beijing , China

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION

Air Distribution and Ventilation Effectiveness in a room with Floor/Ceiling Heating and Mixing/Displacement Ventilation

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

Simulation of Full-scale Smoke Control in Atrium

Aalborg Universitet. Diffuse Ceiling Inlet Systems and the Room Air Distribution Nielsen, Peter Vilhelm; Jensen, Rasmus Lund; Rong, Li

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

Residential ventilation concepts based on the idea of displacement airflow distribution

Comparison of Thermal Comfort by Radiant Heating and Convective Heating

Study of Numerical Analysis on Smoke Exhaust Performance of Portable Smoke Exhaust Fan

Numerical investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper balconies with open upstand

Computer Simulation Investigation on the Effect of Channelled and Unchannelled Screens on Smoke Contamination in Atriums Upper Balconies

Ventilation Strategies for Healthy IEQ and Energy Efficiency

INDOOR CLIMATE IN HEATING CONDITION OF A LARGE GYMNASIUM WITH UNDER-FLOOR SUPPLY/RETURN SYSTEM

To describe human body heat transfer, the concept. Thermal comfort with radiant and convective cooling systems. Articles. REHVA Journal June

power-saving period in summer, in which one of the indoor units was forced to change from a cooling mode to a fan mode, was introduced, and the effect

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

ASHRAE JOURNAL ON REHEAT

IMPLEMENTATION OF DISPLACEMENT VENTILATION SYSTEM BY USING A WALL-MOUNTED AIR CONDITIONER

ASSEMBLY HALL AIR DISTRIBUTION

American Society of Heating, Refrigerating and Air-Conditioning Engineers

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

NUMERICAL SIMULATION OF FIRE SPREAD IN TERMINAL 2 OF BELGRADE AIRPORT. PO Box 522, Belgrade, Serbia and Montenegro

DESIGN OF AIR-CONDITIONING SYSTEM FOR SARS WARDS. By Yuguo Li and SARS Busters * Background

A Novel Heat Recovery System for High Temperature and High Humidity Gas Qing Hao1, a, Meng Si2, b

Aspirating Gas Detection CFD Modelling Predicts Application Performance

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Experimental Comparison of Natural Convection Heat Transfer from a Blackened V-Fin Array

Smoldering Propagation Characteristics of Flexible Polyurethane Foam under Different Air Flow Rates

AN ANALYSIS OF THE ACTUAL THERMAL PLUMES OF KITCHEN APPLIANCES DURING COOKING MODE

UFAD and Displacement Ventilation. Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

Vertical Distribution of Air Temperatures in Heated Dwelling Rooms

,Chaojian He6, f. School of Guangxi University, Nanning , China.

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

How to ensure Thermal Comfort in buildings with CFD

EXPERIMENTAL INVESTIGATION OF THE AIR CLEANING EFFECT OF A DESICCANT DEHUMIDIFIER ON PERCEIVED AIR QUALITY

Comfort and health-indoor air quality

Comparison of radiant and convective cooling of office room: effect of workstation layout

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

EXPERIMENTAL STUDIES ON THE EFFECT OF THE FIRE POSITION ON PLUME ENTRAINMENT IN A LARGE SPACE

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

European Researcher, 2014, Vol.(75), 5-2

AIRFLOW PATTERN AND PERFORMANCE ANALYSIS OF DIFFUSE CEILING VENTILATION IN AN OFFICE ROOM USING CFD STUDY

Stock Vessels for Improved Quality and Energy Savings

STUDY ON THE EFFECTIVENESS OF AIR-CONDITIONING AND VENTILATION SYSTEMS BY CFD ANALYSIS IN HOUSES

Impact of heat load distribution and strength on airflow pattern in rooms with exposed chilled beams

Performance evaluation of an innovative fan-coil unit: Low-temperature differential variable air volume FCU

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

Improvement of Temperatures Stratification caused by Air-conditioner. by means of Ceiling Fan in Classroom

Structure Improvement and Flow Field Analysis of Condenser in Freeze drying Equipment

A Study of Drying Uniformity in a New Design of Tray Dryer

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

A STUDY ON THE DEVELOPMENT OF A DEODORIZATION UNIT FOR THE TOILET BIDET

APPLICATION OF CFD SIMULATIONS FOR LOCATING OUTDOOR UNITS ON HIGH RISE TOWER Basant Kumar Gupta 1, Anand Patil 2

Study of Hot-air Recirculation around Off-road Tier-4 Diesel Engine Unit Using CFD Abbreviations Keywords Abstract Introduction and Background

Unit 4: Science and Materials in Construction and the Built Environment. Thermal Comfort

Cooling the Data Center

Heat transfer and heating rate of food stuffs in commercial shop ovens

Yan Xue 1 and Qingyan Chen 2,1* Abstract

Indoor Air of a Double-Storey Residential House in Malaysia

Study of air circulation inside the oven by computational fluid dynamics.

CFD Analysis of Fire Characteristics on Subway Junction Station

Displacement Ventilation in Classrooms

Effect of the Use Pattern on Performance of Heat Pump Water Heater

Sprinklers Modeling for Tunnel Road Fire Fighting

Heat Transfer in Evacuated Tubular Solar Collectors

design brief This design brief provides an introduction into the design and application of DV. It addresses the following issues:

Physical Mechanism of Convection. Conduction and convection are similar in that both mechanisms require the presence of a material medium.

Optimisation of cooling coil performance during operation stage for improved humidity control

Center for the Built Environment October 2013

INDOOR HUMAN THERMAL COMFORT OPTIMAL CONTROL WITH DESICCANT WHEEL COOLING SYSTEM

Experimental study of fan coil assisting radiant floor heating system

Typologies of Hybrid Ventilation in Schools

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Numerical study of heat pipe application in heat recovery systems

Human response to thermal environment in rooms with chilled beams

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger

A Method of Heat Exchange Structure Optimization of the Cricoid Plastic Parts

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

Improving Single-Sided Room Ventilation by Using a Ceiling Fan

Thermal Environment Evaluation in Commercial Kitchens of United States

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

Experimental Analysis of a Stirling Refrigerator Employing Jet-Impingement Heat Exchanger and Nanofluids

Underfloor Air Distribution:

STUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER

RESULTS FROM HOUSE APPLIANCE SAFETY AND DEPRESSURIZATION TESTS CONDUCTED ON SINGLE FAMILY HOUSES UNDERGOING SOUND INSULATION

Underfloor Air Systems. How It s Different: Overhead vs. Underfloor Air Systems

Transcription:

Journal of Environmental Protection, 2013, 4, 638-646 http://dx.doi.org/10.4236/jep.2013.46073 Published Online June 2013 (http://www.scirp.org/journal/jep) The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen * Jianping Yuan 1, Longyan Wang 1#, Zhixia He 2, Xiaofan Liu 1 1 Research Center of Fluid Machinery and Engineering, Jiangsu University, Zhenjiang, China; 2 School of Energy Resources and Power Engineering, Jiangsu University, Zhenjiang, China. Email: # Wanglongyan_2006@163.com Received March 26 th, 2013; revised April 29 th, 2013; accepted May 27 th, 2013 Copyright 2013 Jianping Yuan et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. ABSTRACT A commercial kitchen is a complicated environment where multiple components of a ventilation system including hood exhaust, conditioned air supply, and makeup air systems work together but not always in unison. And the application of an appropriate ventilation system is extremely vital to keep the catering kitchen comfortable, which consequently promotes the productivity and gains. Application of two systems (traditional mixing ventilation system and thermal displacement ventilation system) is compared in a typical kitchen environment using computational fluid dynamics modeling which was used to investigate the difference between mixing and displacement ventilation (DV). It was reported in two parts, one on thermal comfort and the other one on indoor air quality. The results show that DV can maintain a thermally comfortable environment that has a low air velocity, a small temperature difference between the head and ankle level, and a low percentage of dissatisfied people, and may provide better IAQ in the occupied zone. So it was persuasive that using thermal displacement ventilation in kitchen environment allows for a reduction in space temperature without increasing the air-conditioning system capacity. Keywords: Kitchen; Displacement Ventilation; Mixing Ventilation; Numerical Simulation 1. Introduction It has been well recognized that a modern commercial kitchen is characterized by high heat loads and big temperature difference. All cooking appliances release heat into the limited space in the kitchen in the form of convection or radiation. And we are aware that an uncomfortable temperature which people work in affects the productivity. It was reported that a temperature increase of 10 F above the comfort level in the space may contribute to a productivity loss as much as 30% (Wyon 1996). And recent regulation on indoor air quality (IAQ) for residential building have increased in severity, which gives us a signal that the living environment with good breathing air quality is significant for humans, not to mention in the worse working space (kitchen). And it is known that mechanical ventilation is the common method to improve the indoor air, which can be divided into mix- * National Natural Science Foundation of China (No. 50979034). Initial Funding for Jiangsu University Professional (No. 09JDG032). # Corresponding author. ing ventilation (MV) and displacement ventilation (DV) [1]. The goal of this paper is to find out the pros and cons of both the two ventilation patterns applied in the catering kitchen. Most conventional kitchens adopt mixing ventilation to cool the space. And the cool conditioned air is typically supplied through ceiling diffusers at a high discharge velocity in a mixing ventilation system. This high velocity is required to create a high momentum air jet for efficient mixing of supply air with room air. It shows that this kind of air distribution may not necessarily be the best fit for a commercial kitchen, since high discharge velocity creates unwanted air movement and cross-drafts in the kitchen which make it hard to capture by hoods and uncomfortable to feel at the same time. It has been noted that an alternative air distribution system that supplies air at floor level and returns air near the ceiling has several advantages over conventional ceiling supply/return systems [2,3]. Floor-supply systems distribute conditioned air directly to the occupied zone that is sub-

The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen 639 stantially closer to the occupants. Rather than mixing the heat and contaminants in the space, as the mixing system does, DV stratifies and displaces them out of the occupied zone into the upper part of the space [4]. As a result the air velocity in the space is low, with no undesired cross-drafts, which makes it easier for the hoods to capture. Prior to the laboratory test, it is important to predict the various performance of this two ventilation system using the CFD technique. Airpak software was used to simulate these two systems numerically and the comparison of performances of both ventilations will be reported in both thermal comfort and indoor art quality (IAQ) two aspects. 2. CFD Model and Boundary Conditions 2.1. Physical Model The computational model was developed based on a commercial program, the Chinese restaurant kitchen of Clancy Hotel (kitchen) Equipment Corporation Ltd. And the object of research is the operation room of the kitchen. The kitchen model entity was simplified properly to establish the physical model for research. The room size was 9.0 m 4.92 m 3.0 m and the displacement ventilation system was floor supply wind with both sides while the mixing ventilation system was ceiling diffuser wind. The sizes of supply air ports and return air ports are 0.4 1.2 and 0.6 0.6, respectively. Figure 1 is the plane figures of simplified models for both MV and DV [5,6]. 2.2. Basic Assumptions The air flow patterns and hear transfer of the indoor space are usually three-dimension turbulent problems, moreover the influence of floating lift need to be taken into consideration necessarily. So the basic hypotheses for the physical models are shown below: Figure 1. Simplified size plane of kitchen. The indoor gases are seen as incompressible. The gas movement within the space is stable and turbulent. It meets the Boussinesq assumption, which means the density is constant except for the buoyancy polynomial in the momentum equations. The kitchen room is well sealed and has no other air leak. Ignore the decentralized radiating influence of lighting bulb and other appliance. 2.3. Ventilation Parameters The designed environment temperature is 27 C, and the boiler power is 3.5 kw with uniform heat dissipation. The refrigerators are treated as just heat source as well as freezers, and the powers are 1019 W and 1221 W, respectively. Cooling load for human bodies is selected as working adults for 116 W each. The exhaust volume of return ports is 1.32 m 3 /s; only carbon dioxide gas was considered for gas pollution source, and CO 2 concentration of supply air is 300 ppm while which of each boiler is 900 ppm; the initial indoor pollution level is 300 ppm. Supply air velocity is 0.25 m/s, temperature is 22 C. 3. Performance Comparison of MV and DV 3.1. Airflow Track Figures 2 and 3 show the indoor air flow track in 120 seconds for mixing ventilation and displacement ventilation system. We figure out that after the supply air get into the kitchen interior from both bottom sides wall, they spread out rapidly in the room and divided into two separating air streams because of the block of working bench, consequently come across the hot air plume of heat source as a result of being sucked to the upper zone of the space. Part of air is discharged from the exhaust hood vents, and the other is expelled from the top vents for DV. As for MV, the supply air enter into the space from the ceiling vents, and then, the cold conditioning air sink in due to the natural gravity, spread out at the bottom of the room, encounter the hot plume and carried to the top space. 3.2. Comfort Under all the aspects of ventilation system performances, the thermal comfort is the most important one. And the thermal comfort obtained through the calculation of MV and DV system will be compared in the following sides: velocity distribution; temperature distribution; predicted percentage dissatisfied (PPD). For the airflow velocity distribution (Figure 4), as it can be seen that the flow within the space which is close to the outside windows and the walls rise due to the high

640 The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen Figure 2. Airflow track for MV. Figure 3. Airflow track for DV.

The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen 641 Figure 4. X = 2.9 cut plane velocity vector. for MV system; for DV system. temperature of the separates in the DV system. The heat source like boiler and fridge freezer will generate massive heat plumes, which take the conditioned air in the lower zone to the upper zone. Nevertheless, the downdraft from the ceilings in the MV system seems like ejecting flow which forms the relative high-speed area. They first flow horizontally in all directions after reaching the ground, and then they go up in the same way as DV system. Generally the velocity magnitude of MV is higher than DV and the airflow characteristic of spatial pattern is cross-flow, the supply flow goes down while the other upward moves. For DV, the flow pattern goes

642 The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen up only among the breathing zone, however it moves up and down for MV, which definitely induces discomfort. The temperature distribution on cut plane X = 4.0 for MV and DV system are shown in Figures 5 and respectively. For DV, the temperature distribution from bottom to the top of the space increases gradually and the temperature stratification is obvious. It can be concluded that more distance space is from the supply air ports, the less temperature gradient decreases. Furthermore, the air spread in horizontal is not so apparent, and the temperature distribution in that direction is uniform relatively. For MV, temperature change in horizontal is slightly larger than DV and the temperature distribution pattern is similar to DV in general. To specially mention, the homogeneity in horizontal direction for MV cannot be assured if it s higher speed velocity. According to the acceptable three thermal environment grades and thermal comfortable standard analysis applied for the Chinese area recommended by domestic scholars for PPD index, we can see the PPD is kept below 20% as a whole, meanwhile the DV PPD overall is lower than MV (Figure 6). Figure 5. X = 4.0 cut plane temperature distribution. for MV system; for DV system.

The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen 643 Figure 6. X = 2.9 cut plane PPD distribution. for MV system; for DV system. 3.3. Indoor Air Quality This paper investigates the IAQ index in the catering kitchen through the analysis of carbon dioxide distribution, the average age of air to make the contrast study of DV and MV system. Figures 7 and show the CO 2 distribution of cut plane X = 2.9 for MV and DV system respectively. It s easy to find out that in DV, the airflow around the workers upward move, which means there s no cross air infection. In the direction of south of workbench and worker there exist a higher concentration of contaminant because of the effect of block, meanwhile it won t affect the IAQ since it s beyond the breathing zone of humans. Yet for MV system around the area next to the vents, the pollutant concentration is particularly large, which will consequently affect the breathing air nearby. So we ve got the conclusion that the air distribution in MV system is not so uniform as that in DV system. The mean age of air from lower zone is less than higher zone (Figure 8), which indicates the displacement

644 The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen Figure 7. X = 2.9 cut plane CO 2 distribution. for MV system; for DV system. effect is stronger. One of the advantages for DV system is that it ensures the stagnation period of the air around the worker is less. Hence, the IAQ of the DV is better than that of MV normally with the same magnitude of flow velocity. Generally speaking, the air in the DV system has higher displacement efficiency in comparison with the air recirculation in the MV system. Moreover, as demonstrated in the figure the mean ages of air for both systems are all less than 100 seconds. 4. Summary This paper analyses index of indoor environment quality like the distribution of air flow velocity, temperature, CO 2 concentration, mean age of air, PPD in kitchen for mixing ventilation and displacement ventilation systematically for the first time. It is concluded that the DV is

The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen 645 Figure 8. X = 2.9 cut plane mean age of air distribution. for MV system; for DV system. better than MV no matter in the aspect of the thermal comfort or the IAQ and demonstrates the feasibility of the application of DV system into kitchen environment. REFERENCES [1] N. H. Boscawen, Displacement Ventilation in Classrooms Report of Visit to Boscawen Elementary School. [2] A. Livchak and D. Nall, Displacement Ventilation-Ap- plication for Humid Climate, Clima 2000/Napoli 2001 World Congress-Napoli I., 2001, pp. 15-18. [3] E. Mundt, Convection Flows above Common Heat Sources in Rooms with Displacement Ventilation System. [4] P. O. Fanger, Thermal Environment Human Requirements, The Environmentalist, Vol. 6, No. 4, 1986, pp. 275-278. doi:10.1007/bf02238059 [5] Y. Liu and K. Hiraoka, Ventilation Requirements for

646 The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen Raised Floor HVAC System, IAQ 97 Healthy Buildings, 1997, p. 32. [6] H.-J. Park and D. Holland, The Effect of Location of a Convective Heat Source on Displacement Ventilation, Building and Environment, Vol. 36, No. 7, 2001, pp. 883-889. doi:10.1016/s0360-1323(01)00014-2