Subj: Shipboard Refrigerant Leak Repair and Record Keeping

Similar documents
(a) 40 CFR 82 Subpart F--National Emission Reduction and Recycling Program (b) OPNAVINST B Chapter 6

PURPOSE OF THE PROCEDURE

Updates to Section 608 ODS Management Program

Refrigerant Management Requirements Update

DEPARTMENT OF DEFENSE OZONE DEPLETING SUBSTANCES REQUISITIONING PROCEDURES

REFRIGERANT PROCEDURE

Refrigerant Standards

COMDTPUB P NVIC JUNE 1995

Under Section 608 of the CAA, EPA has established regulations (40 CFR Part 82, Subpart F) that:

Issue Update: Revised Recommended Language for Verification Contracts and Statements for Recycling Appliances and Vehicles

Refrigerant Rule Update

Workshop F Managing Ozone Depleting Substances Compliance, New Rule Changes and How that Impacts Your Compliance Program

FACT SHEET 9 Large Air-Conditioning (air-to-air)

APPENDIX 112D. PERCHLOROETHYLENE DRY CLEANING NESHAP (40 CFR 63 Subpart M) CAA SECTION 112 NESHAP

FACT SHEET 9 Large Air-Conditioning (air-to-air)

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Ozone Depleting Substances (ODS) Rule Updates

HALON REDISTRIBUTION/RECOVERY/RECYCLING/RECLAIMING

EXHIBIT G REFRIGERANT MANAGEMENT POLICY

Emergency response lock box unit contents and maintenance.

JEFFERSON COLLEGE COURSE SYLLABUS HRA125 REFRIGERATION AND A/C MECHANICAL SYSTEMS. 5 Credit Hours. Prepared by William Kaune November 30, 2010

Refrigerant Rule Revisions: Is Your Facility Prepared? MCTA Conference November 29, 2018

AHRI Guideline N Guideline for Assignment of Refrigerant Container Colors. ARI Standard 1200

Actions to Control Emission of HFCs in Japan

The Ozone-depleting Substances Control Regulations

ABSTRACT. State adoption is not required, See Paragraph V. Directorate of Compliance Programs. 200 Constitution Avenue, NW Washington, DC 20210

Guided Learning Hours (GLH) 4 Invigilated Assessment (IA) 1 Total Qualification Time (5)

FACT SHEET 6 Transport Refrigeration

Guidance Note EC Regulation No 842/2006 on Certain Fluorinated Greenhouse Gases. BFPSA Guidance for the Fire Protection Industry

AHRI Guideline N with Addendum Guideline for Assignment of Refrigerant Container Colors. ARI Standard 1200

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

DEPARTMENT OF DEFENSE OZONE DEPLETING SUBSTANCES TURN-IN PROCEDURES

COMMISSION REGULATION (EU)

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

CHAPTER A-6 FIRE PROTECTION

Safety Program. Eastern Electrical Testing Corporation 2 Skyline Drive Clarks Summit, PA (570)

Guidance for the EPA Halon Emission Reduction Rule (40 CFR Part 82, Subpart H)

Fire FY Performance Plan

BMA INFORMATION BULLETIN No. 97 FIRE FIGHTING EQUIPMENT

FPA Australia submission to the review of the Ozone Protection and Synthetic Greenhouse Gas Management Act 1989 and associated legislation.

Ozone Protection and Synthetic Greenhouse Gas Management Regulations 1995

Guidance for Stationary Refrigeration & Air-Conditioning

5. MVAC-like appliance include appliances using R22 refrigerant a. True b. False

trinityconsultants.com

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

Division F Of G Of The 1987 Standard Industrial Classification Manual

Ref: (a) (b) Defense Authorization Act of FY93 (c) Navy Department Acquisition Procedures Supplement (NAPS), Part 5210 Encl:

NZQA Expiring unit standard 3397 version 4 Page 1 of 5. Convert an automotive air conditioning system from R-12 to R-134a

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

Test Procedure for Clothes Dryers and Room Air Conditioners. NOPR Public Meeting

Incident Symbology Framework, Guideline, and Operational Implementation Guidance Version 2.0

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Merrill A. McPeak, General, USAF

JEFFERSON COLLEGE COURSE SYLLABUS HRA 249 COMMERCIAL REFRIGERATION SYSTEMS. 5 Credit Hours. Prepared by: William Kaune November 30, 2010

Denver s Green Building Ordinance

Inverter Swimming Pool Heat Pump

Ozone Depleting Substance Management Plan Yokota Air Base, Japan

Responsible Care Product Stewardship for Refrigerants

AMENDMENT NO. 1 TO IS 2878:2004 FIRE EXTINGUISHER, CARBON DIOXIDE TYPE (PORTABLE AND TROLLEY MOUNTED) - SPECIFICATION

STANDARDS FOR VAPOUR EMISSION CONTROL SYSTEMS ( MARPOL reg VI/15 )

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Oklahoma. 265: Incorporated national codes and standards The following national codes and standards are incorporated by reference:

IPC CODE AND COMMENTARY

Methodological tool Calculation of baseline, project and leakage emissions from the use of refrigerants

Optimising Performance

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

THINGS YOU CAN DO TO CONSERVE ENERGY

Recycling Equipment for Processing recycled Refrigerators

Distribution Restriction Statement

b. Laser Mishap. Any unplanned or unexpected event causing material loss or damage or causing personnel injury from laser use.

Department. The. (Montreal and been hailed as. The. to disease, can yields. destruction of. process. The UAE is a. The. exist and.

Quality Assurance Plan for Conducting Radon Measurements

MINIMUM PERFORMANCE REQUIREMENT FOR AIR FORCE FLIGHTLINE FIRE EXTINGUISHERS:

UNCLASSIFIED TECHNICAL MANUAL. Hoshizaki Cubelet Ice Dispenser Model DCM-270BAH. HOSHIZAKI AMERICA, INC. 618Highway74South Peachtree City, GA 30269

Daikin s Policy. and Comprehensive Actions on the Environmental Impact of

TECHNICAL MANUAL OPERATOR, UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST) FOR

GUIDELINES FOR SIZING WATER HEATERS California Conference of Directors of Environmental Health September, 1995

IC Chapter Severe Weather Warning Sirens

A/C Refrigerant. Air Conditioning systems use refrigerant to move heat from air inside the car to air outside the car

[Docket No. FAA ; Directorate Identifier 2004-CE-25-AD; Amendment ; AD ]

Transitioning to Alternatives and Challenges in Japan

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS MD5-601 AND MD5-603

Voltbek Home Appliances recycling program for E-Waste

CMEP-OL. Oil less Explosion proof Recovery Pump. Operating Manual. Nanjing Wonfulay Precison Machinery Co.,Ltd

An ordinance amending Chapter 51, Dallas Development Code: Ordinance No , as

Fire Protection in the Mining Industry. Garry Kwok Board Member

Important Safety Notice

OHIO UNIVERSITY RADIATION SAFETY REVIEW

OPERATION MANUAL. Model: IC702/703 Ice Maker

DEPARTMENT OF THE ARMY TECHNICAL MANUAL TECHNICAL MANUAL

DRAFT NFPA 805 TRANSITION PILOT PLANT OBSERVATION GUIDANCE

Chapter 2. Alternatives to HCFCs and their Characteristics

Airworthiness Directives; Kidde Aerospace Part Number (P/N) Hand-Held Halon Fire Extinguishers

Control of refrigerant gases during manufacture, installation, servicing

Title: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7

Title: Fire Protection Effective Date: 7/1/2013 Control Number: THG_0039 Revision Number: 1 Date: 10/23/2015 Annual Review Completed: 5/13/2015

H gh-p led Combust ble Storage. Application Guide 2009 Edition

An Industry Prepares Service Technicians for Refrigerant Transition

ELEVATOR RESCUE PROCEDURE

Fire Protection Industry Board (ODS & SGG) Risk Management Plan. A risk management plan for storing and disposing of fire extinguishing agents

Transcription:

I. Navy ODS Advisory 96-03 II. III. Subj: Shipboard Refrigerant Leak Repair and Record Keeping References: (a) CNO WASHINGTON DC 051558Z JUN 96, Navy Policy On Regulation Of Shipboard Air Conditioning And Refrigeration Systems (b) 40 CFR 82 Subpart F--National Emission Reduction and Recycling Program (c) COMSC 211207Z JUN 96 Shipboard Refrigerant Leakage (d) OPNAVINST 5090.1B Chapter 6 dated 14 NOV 94 (e) NSTM S9086-RW-STM-010 Chapter 516 Refrigeration IV. Cancellation: None V. Applicability: All Navy Ships Operating Refrigerating Units With A Charge Greater Than 50 lbs. VI. Background: A. Reference (a) states that air-conditioning and refrigeration (AC&R) systems designed or built to military specifications on board ships owned, operated, or bare-boat chartered by the U.S. Navy and Military Sealift Command (MSC) fall under the reference (b) exemption for military-unique systems. Therefore, these systems are not subject to the requirements of reference (b), including those requirements that are related to AC&R leakage rates. B. Although exempted systems are not subject to the requirements of reference (b), reference (a) also states that the Navy is committed to minimizing refrigerant leakage from AC&R systems. Reference (a) sets leakage-rate performance goals of 15% for airconditioning systems and 35% for refrigeration systems. Navy and MSC ships operating AC&R systems built to General Specifications or Military Specifications with an installed refrigerant charge of 50 pounds or more and that contain R-11, R-12, R-114, R-22, R-134a, or R-236fa shall adopt these performance goals. C. Many AC&R systems on board ships owned, operated, or bare-boat chartered by the MSC are built to commercial specifications and therefore are subject to the requirements of reference (b). Owners and operators of systems that are not military unique should follow the guidance outlined in reference (c). VII. Action: A. In accordance with reference (a), AC&R systems built to military specifications aboard Navy and MSC ships with an installed refrigerant charge of 50 pounds or more shall adopt the following performance goals: 1. Ensure that the annualized leakage rate from shipboard chilled-water airconditioning systems does not exceed 15% of the total installed charge. 2. Ensure that the annualized leakage rate from ship-stores and cargo refrigeration systems does not exceed 35% of the total installed charge.

B. Method By Which To Measure And Monitor Refrigerant Leakage: Attachments (1) and (2) are provided to assist ships force in complying with these requirements. These forms are provided for guidance only and may be revised or substituted to suit individual needs. The rate at which refrigerant is leaking from shipboard AC&R equipment can be estimated using the following procedure: 1. Attachment (1) is a day-to-day Service/Maintenance Report Log that can be used to document all service and maintenance conducted on AC&R systems. Attachment (1) is used to keep track of a system s refrigerant consumption. This form is also used to estimate the system s leakage rate in order to determine compliance with reference (a). 2. Identify Total Installed Charge: The total installed charge of the system may be obtained from the system technical manual, Fleet Technical Support Center representative, or the In-Service Engineering Agent. 3. Identify Maximum Allowable Annual Leakage Rate: Using paragraphs VII.A.1. and VII.A.2., determine whether the maximum allowable annual leakage rate for the system is 15% or 35%. 4. Accidental Discharges and Refrigerant Removal: Between refrigerant chargings, it is possible that refrigerant has been removed or recovered from a system or an accidental discharge or venting has occurred. These events should not be considered when estimating system leakage; and failure to record and account for refrigerant removal and accidental discharge will cause the technician to calculate higher-thanactual leakage rates. Therefore, refrigerant removal and accidental discharges should always be recorded by technicians. The amount of refrigerant removed from a system can be accurately estimated by measuring the change in weight of recovery cylinders and should always be recorded on Attachment (1). The amount of refrigerant lost through accidental discharges must be estimated by the trained technician and should always be recorded on Attachments (1) and (2). 5. Net Leakage: The net leakage of a system refers to the system s net refrigerant leakage or net refrigerant consumption. The net leakage is often calculated each time refrigerant is added to a system and covers the period of time since refrigerant was last added to the system. The net leakage can be calculated as follows: Net Leakage Since Last Charging = (Refrigerant Added Since Last Charging) - (Refrigerant Removed Since Last Charging) - (Losses Due To Accidental Discharge or Venting Since Last Charging). 6. Annualized Leakage Rate: The annualized leakage rate in terms of percent per year can be estimated by dividing the system s net refrigerant leakage (paragraph 5, above) by its installed charge (paragraph 2, above) and prorating the result over the entire year. The following formula may be used: Annualized Net Leakage 365 (days/yr) Leakage = -------------------------- x ---------------------------- x 100 Rate (%) Installed Charge Days Since Refrigerant Last Added (days) The result of this formula should be compared to the system s maximum allowable annual leakage rate (paragraph 3, above). If the system is exceeding its maximum allowable annual leakage rate, then shipboard personnel should take immediate action to repair leaks. 2

C. Points of Contact: 1. CNO (a) Ms. Catharine Cyr, CNO N451I, (703) 602-5335, DSN 332-5335, fax (703) 602-2676, cyrc@n4.opnav.navy.mil. 2. COMNAVSEASYSCOM (a) Mr. David Breslin, NAVSEA 03L14, (703) 602-9025 x240, DSN 332-9025 x240, breslin_david@hq.navsea.navy.mil. 3. COMSC (a) Mr. John Austin, MSC, (202) 685-5042, john.austin@smtpgw.msc.navy.mil. 4. For general questions on ODSs or to receive information on alternatives to ODSs, contact the Navy CFC & Halon Clearinghouse, (703) 769-1883, navyozone@aol.com, http://home.navisoft. com/navyozone. D. Incorporation of Advisory: 1. This advisory will be incorporated in the next revision of references (d) and (e). VIII. Advisories In Effect: Advisory Subject Applicability: 95-01 Mission-Critical Applications of Class I All Navy Operating Ozone-Depleting Substances Forces and All Activities and Facilities Supporting Operational Units 96-01 Ozone-Depleting Substance (ODS) Supply Canceled and Superseded by Support 96-01A 96-01A Ozone-Depleting Substance (ODS) Supply All Navy Operating Forces, Support New Ship Construction, and All Activities and Facilities Supporting Operational Units 96-02 Refrigerant Leak Repair and Record Keeping All Navy Activities and Facilities Owning Or Operating Air-Conditioning and Refrigeration (AC&R) Units Greater than 50 lbs 96-03 Shipboard Refrigerant Leak Repair and All Navy Ships Operating Record Keeping Refrigerating Units With A Charge Greater Than 50 lbs 3

Service/Maintenance Report Log Appliance/Unit Number Total Installed Charge Maximum Allowable Annual Leakage Rate 1 Date Service / Maintenance Action Technician Refrigerant Added Refrigerant Removed Loss Due To 2 Accidental Venting Net Leakage 3 Annualized Leakage Rate 4 (%) Leak Repaired (Yes/No/NA) Comments Notes: 1. Maximum Annual Leakage = 35% (Refrigeration) or 15% (Air Conditioning). 2. Each time an accidental or unintentional release occurs, the technician must document the release on an accidental/unintentional release form (Attachment (2)). 3. Net Leakage Since Last Charging = Refrigerant Added Since Last Charging - Refrigerant Removed Since Last Charging - Loss Due to Accidental or Unintentional Venting Since Last Charging. 4. Annualized Leakage Rate = (Net Leakage / Installed Charge) x (365 / Number of Days Since Refrigerant Last Added) x 100 Maintain For Record Purposes For 3 Years Attachment (1)

Accidental or Unintentional Venting Report Date Location Refrigeration Unit Type of Refrigerant Vented Approx. How Many Pounds Were Vented Description of Accidental Venting Incident What Was the Cause of the Release? What Precautions Have Been Taken To Prevent This From Happening Again? Technician Name/Rank or Grade Certification Number Engineering Officer Signature Date Engineering Officer Printed Name and Rank Maintain For Record Purposes For 3 Years Attachment (2)