TX6831 Data Sheet. Features. Benefits

Similar documents
TX6351 TX6352 Sentro 1 Universal Gas Detector Contents

PERSONAL COMBUSTIBLE GAS DETECTOR

INSTRUCTION MANUAL (ATEX)

4) Intrinsic Safety Certification

Rosemount 3490 Series

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

YO3 - YO4 / YL4 - YO5 / YL5

OilSET-1000 (12 VDC)

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Ex Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder

SET-2000 Hi Level/Oil

DB5 Intrinsically Safe Sounder Type DB-5

GasAlertMicroClip X3 Specifications

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

monitoring air flow gas detection temperature sensors CASE STUDY GAS DETECTION SYSTEM AT LOWER LEA VALLEY CABLE TUNNELS For Murphy Group/National Grid

Danfoss gas detection units

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

14300 MAINS SEPARATOR ALARM MANUAL

E2S Datasheet v10a

APPLICATION DATA SHEET

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Oxygen (O2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

SET Installation and Operating Instructions. Level switch for one sensor

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Fire Signalling. Signalling Solutions

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

Gas cylinder scale Model GCS-1

Danfoss gas detection unit Type GD Heavy Duty

Danfoss gas detection units

SET-2000 Oil/Sludge 12 VDC

Rosemount 4500 Hygienic Pressure Transmitter. Start

Software Version 2.01 LEVEL MONITOR MODEL 220

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

TER Active Room Temperature Sensor (Controller),

Indoor/outdoor resistance thermometer Model TR60

Rosemount 4500 Hygienic Pressure Transmitter

RT FLOW RATE TOTALISER

Two-Channel Gas Controller

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

Universal Tank Alarm Type Installation, Operation & Maintenance

Rosemount 752 Fieldbus Remote Indicator

P R O D U C T D ATA S H E E T

Instrumentation Products and Applications

Intellia Sounder Bases and Sounder Beacon Bases

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

Annubar Flowmeter Series

FlexSQUARE Square shaped beacons

Technical data sheet TDS0060

INSTRUCTION MANUAL (ATEX / IECEx)

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Door Release Power Supply

805QS Pressure Switch-Transmitter

FDCL221-Ex Line adapter (Ex)

Flopurge TS. Operation Manual

UDC100 Universal Digital Controller Specifications

AUDIBLE SIGNALIZATION

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

HART TOCSIN 903 SINGLE CHANNEL GAS DETECTOR USER INSTRUCTIONS. Oliver IGD Limited NEW WITH OPTIONAL. 4a Pepper Road Stockport SK7 5BW England

TraceNet ECM Series Control System

ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X

Dräger Polytron 5100 EC Detection of toxic gases and vapors

OSA 3. Level alarm for oil separator. Afriso Ema AB. Kilvägen 2 SE Arlöv Sweden T +46-(0) F +46-(0)

EasyLog Data Logger Series

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Earth-Rite II PLUS Static Earthing System

Conventional Fire Alarm System 2014 V1.2

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

ANALOX 3000 Carbon Monoxide Monitor

HYTEK ATEX APPROVED BUND ALARM

XP95 Sounder VAD Base

BA374C Intrinsically safe field mounting indicating temperature transmitter

Dräger Polytron 8000 Stationary gas detector (EC)

Snifter ATEX22 VERSION. User Manual. Distributor

Product Manual. The Essential Guide for Safety Teams and Instrument Operators

IGD.CO.UK

Magnetostrictive sensor For bypass level indicators Model BLM

WARNING FIRE DOOR CLOSING

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Quick Start Manual July pointek CLS100

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

HTC-915-CONT. Heat-Trace Control system

ELECTRONIC SOUNDER STROBE Model : AVD-C407

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

Technical data sheet TDS0034

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor

Duct and Rough Service Carbon Monoxide Sensor

ATEX, NOMENCLATURE AND CODING

Transcription:

Audio/Visual Alarm Combined audible and visual alarm signalling, for use with sensors and monitoring systems Environments: Mining Tunnelling Machine monitoring Features TX6831 For use with sensors and monitoring systems in hazardous areas Compact and strong moulded polycarbonate housing Certified intrinsically safe for use in Group I hazardous areas High intensity LED all-round visual alert with optional 85 db audible sounder 1 second flashing LED visual alert Choice of flashing LED visual alert colours available: Amber Blue Green Red For use with sensors and monitoring systems in hazardous areas Optional confidence alert at 15 second intervals Choice of input signal: Contact state Analogue Choice of analogue input signal: 4 to 20 ma 0.4 to 2 V User configurable alarm setpoint, can also be configured for Under or Over alarm Benefits Cost effective - self contained construction saves cost of installation and cabling The audio visual alarm can be fitted directly to some Trolex sensor/transmitters using the terminals inside the sensor housing, or can be supplied fitted directly to a junction box Simple and easy to mount - compact dimensions make it easy to fit the Audio/Visual Alarm where space is at a premium Minimal weight, the Audio/Visual Alarm weighs only 100 g Rugged design is environmentally protected to IP65 standards TX6831-DS-EN-01 Page 1 of 8

Functional Overview Supplied in a compact and strong moulded polycarbonate housing, this high-intensity LED visual alarm has an optional 85 db audible sounder. The alarm can be fitted directly to many Trolex sensor/ transmitters using the terminals inside the sensor housing, or can be supplied fitted directly to a junction box. Choice of input signal; contact state or analogue. 4 to 20 ma or 0.4 to 2 V analogue input signal compatibility, with user adjustable alarm trigger setpoint, can be configured for under or over alarm. Certified intrinsically safe for use in Group I hazardous areas, for use with sensors and monitoring systems in hazardous areas. Versions available with visual alarm only. Technical Information Light source: High intensity LEDs Input signal: Contact state - Open or Close for alarm Analogue signal with potentiometer adjustable setpoint, can be configured for Over or Under alarm Audible alarm: Alarm indication: Alarm signal out of limits: Hysteresis: Housing material: Protection classification: Nett weight: High intensity audible sounder 85 db @ 1 m (12 V dc) Flashing visual alert every 1 second Optional audible alarm Optional confidence alert at 15 second intervals Alternating LED flash with double sounder beep - when fitted 5% of setpoint Moulded polycarbonate Protected to IP65 Sounder to IP54 100 g Electrical Information Supply voltage: Power consumption: Analogue input signal: State input signal: 7.5 to 16.5 V dc 15 ma - mean 75 ma peak during LED flash 4 to 20 ma OR 0.4 to 2 V options Low: 0 V min. to 1.1 V max. High: 1.3 V min. to +Supply V max. TX6831-DS-EN-01 Page 2 of 8

Dimensions Audio Visual Alarm Enclosure Drilling Details TX6831-DS-EN-01 Page 3 of 8

Connections Unit Connections Connecting to a 4 to 20 ma Signal Loop Connecting to a 0.4 to Connecting to a Volt Connecting to a 5 V 2 V Signal Source Free Input Contact State Input Checkpoint The TX6831 Audio/Visual Alarm must only be interconnected with approved power supplies, signal sources and monitoring equipment when used in hazardous areas. TX6831-DS-EN-01 Page 4 of 8

Setup Type of Input Signal A 4 to 20 ma Analogue input 0.4 to 2 V Analogue input 5 V State input Contact State input OFF OFF ON ON Alarm Setpoint Mode B Analogue input Analogue input Voltage free contacts Alarm on Rising signal OFF Alarm on Falling signal ON Alarm on High level OFF Alarm on Low level ON Alarm on contacts Closing ON Alarm on contacts Opening ON Adjusting the Setpoint The alarm setpoint can be configured by adjusting the Setpoint potentiometer. By default the audio/visual alarm is configured with an alarm level of 50% of full scale. Connect an approved test instrument configured to measure 0 to 2 V to the Test Point. Power up the audio visual alarm, refer to the Connection diagrams on page 4 if necessary. The output voltage from the test point is linear and proportional to the alarm level, 0.4 V equals 0% of full scale and 2.0 V equals 100% of full scale. Each voltage increase of 0.016 V equals an increase of 1% of full scale. By default the audio/visual alarm is configured with an alarm level of 50% of full scale, ie. 1.2 V. With the audio/visual alarm positioned as above, turn the potentiometer clockwise increases the alarm setpoint or turn it anti-clockwise decreases the alarm setpoint. Use a small screwdriver turn the potentiometer and set the alarm setpoint to the desired level. TX6831-DS-EN-01 Page 5 of 8

Application A TX6373 Gas Sensor fitted with a TX6831 Audio/Visual Alarm - 4 to 20 ma A TX5921 Vortex Air Flow Sensor fitted with a TX6831 Audio/Visual Alarm - 4 to 20 ma TX6831-DS-EN-01 Page 6 of 8

Order Reference TX6831 - Audio Visual Alarm ATEX Group I.01 Input - 0.4 to 2 V.11 Input - 4 to 20 ma.12 Input - Contact state.14 Colour - Red.91 Colour - Green.93 Colour - Blue.94 Colour - Amber.95 With sounder.901 Without sounder.902 TX6831.... Certifications ATEX Certification Ex Certificate number: Ex Certification codes: SIRA 99ATEX2152X I M1 EEx ia I (Ta = -20 C to +60 C) Special Conditions for Safe Use Under normal or fault conditions, the internal temperature of this equipment may rise above 150 C, therefore, care shall be taken when the enclosure is opened to ensure that no dust enters the equipment. General Conditions for Safe Use Prior to installation, it is essential that user refers to the above certificate to ensure that the termination and cable parameters are fully complied with and are compatible with the application. Copies of certificates are available from Trolex. ATEX Directive (94/9/EC) ANZEx Certification Ex Certificate number: Ex Certification codes: ANZEx 12.3005X Ex ia I (Ta = -20 C to +60 C) Conditions for Safe Use Prior to installation, it is essential that user refers to the above certificate to ensure that the termination and cable parameters are fully complied with and are compatible with the application. Copies of certificates are available from Trolex. TX6831-DS-EN-01 Page 7 of 8

Certifications - continued Russia Customs Union Ex Certificate number: Ex Certification codes: TC RU C-GB.ГЂ.05.B.00325 PO Ex ia I Ma X Conditions of Use Prior to installation, it is essential that user refers to the above certificate for any specific conditions of use. The user must ensure that the termination and cable parameters are fully complied with and are compatible with the application. Copies of certificates are available from Trolex. South Africa MASC Ex Certificate number: Ex Certification codes: MASC M/11-222X Ex ia I (-20 C Ta +60 C) Specific Conditions of Use Under normal or fault conditions, the internal temperature of this equipment may rise above 150 C, therefore, care shall be taken when the enclosure is opened to ensure that no dust enters the equipment. General Conditions of Use Prior to installation, it is essential that user refers to the above certificate to ensure that the termination and cable parameters are fully complied with and are compatible with the application. Copies of certificates are available from Trolex. India Test Report No: Ex certified for Group I (Mining): ERTL(E)/TES/T238/0064/11-12 Ex ia I (-20 C Ta +60 C) Conditions of Use Prior to installation, it is essential that user refers to the above test report for any specific conditions of use. The user must ensure that the termination and cable parameters are fully complied with and are compatible with the application. Copies of test reports are available from Trolex. Copyright and Trademarks 2015 Trolex Limited. Trolex is a registered trademark of. The use of all trademarks in this document is acknowledged. Document history: Issue 01 2 April 2015 First publication of this document Newby Road, Hazel Grove, Stockport, Cheshire SK7 5DY, United Kingdom +44 (0)161 483 1435 sales@trolex.com TX6831-DS-EN-01 Page 8 of 8