Single Gas Detector. Long-term solution H 2 S O 2 SO 2 NH 3 PH 3. Cl 2. ClO 2 NO 2 HCN ETO O 3

Similar documents
4-gas Detector with Pump

Multi-gas made simple

Order Sheet. Wear yellow. Work safe.

multi-gas detectors Multi-gas made easier Wear yellow. Work safe.

Gas Detection. PORTABLE GAS DETECTION Product Guide

Gas Detection. Product Guide EMEA PORTABLE GAS DETECTION

Bw Gas Alert Clip 2 H2s Extreme User Manual

multi-gas detector Go the distance, and save Wear yellow. Work safe.

Monitores Personales. Personal Monitor

Honeywell Analytics. Order List BW Clip & IntelliDoX

OCCUPATIONAL HEALTH, SAFETY & INDUSTRIAL PRODUCTS

International Edition. The Professionals Choice for Air Sampling Equipment

G-TECTA TM. Portable Gas Detection Instruments

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

OLC(T) 100 FIXED GAS DETECTOR

Gas Detection. Honeywell BW Solo. The next generation in portable single gas detection.

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

GAS DETECTOR ST400EC PART.NO

ALTAIR 5X Multigas Detector

GasAlert. Introduction. WWarning. Table 1. GasAlert Models. Gas Monitored

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

3M Oldham OLCT 100. Description. Fixed Gas Detector

User Manual. Single Gas Detector

GasAlertMicroClip X3 Specifications

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

An easy and flexible way to do gas detection.

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

up to 1.2 m or 3.9 ft. deep). So if you drop the Honeywell BW Ultra in a vat or take it into a dust-prone environment,

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

Sieger Apex. Flexibility that meets your requirements

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

VENTIS PRO SERIES. Product Guide

Model D12. Digital Gas Transmitter

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

ALTAIR 5X Multigas Detector Product Specification

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

MICRO III (G202 / G202s / G212) Single Gas Detector

Micro IV Operation Manual

Toxic Gas Detection. Model F12. Toxic Gas Detection

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

SP-220. Features. Combustible handheld gas leakage detector

Micro IV. Single Gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

MSA Portable Gas Detection

Safe Operation Manual. Honeywell IQ Force Gas Detector

Dräger X-am 5000 Multi-Gas Detection

Frequently Asked Questions

Micro III (Models G203, G203S, and G213) Operation Manual

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

The Dräger X-am 1700/2000 are a new generation of personal gas detectors.

Single Gas Detector. Quick Reference Guide

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Microtector II G gas-detector with performance test approval. Worldwide Supplier Of Gas Detection Solutions

Hygrometer / Air Quality Meter

ALTAIR 5X Multigas Detector

Leak detector for refrigerant gases R22, R134a, R410A, R407C...

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

ESD500. ESD500 Combustible / Toxic Gas Detector

T82. Instruction Manual. Single Gas Monitor GUARANTEED. FOR LIFE. P/N REV 0 PRINTED ,000 Specifications Subject to Change

Dräger X-am 5000 Multi-Gas Detection

MICRO IV. Operation Manual. Single Gas Detector

Dräger X-am 7000 Multi-Gas Detection

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Dräger Pac 7000 Single-Gas Detection Device

SC-01 Operator s Manual

P R O D U C T D ATA S H E E T

IAQ_100 C Package

RIG RAT III. Wireless Multi-Point Gas Detection System. The Stand-Alone Solution

Gas Detection For Life

ESD3000 ESD200 Combustible / Toxic Gas Detector

The GasWatch 2 will operate for over 3,000 hours on one battery (about 1 year normal use). And yes, the GasWatch 2 even tells the time!

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

3SP_H2S_50 Package

PHD6. Flexible, comprehensive monitoring backed up by high performance functionality

Choosing the best confined space gas detector

Honeywell EC-P2 EC-P2. Gas Detector CHARGE BATTERY WHEN NOT IN USE. Instruction Manual

GasAlertMicro 5 / PID / IR

PRODUCT GUIDE. Gas Leak Detectors Gas Monitors Pipe & Joint Locators Calibration Stations Data Management MUNICIPAL SERVICES

M2A Transmitter Operator s Manual

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

EC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

IGD.CO.UK

IRwin. Methane Leak Detector INNOVATIVE METHANE DETECTOR SYSTEM QUALITY ASSURANCE IN THE AUTOMOTIVE INDUSTRY FOR EASY SURVEY OF GAS PIPELINES

Transcription:

Single Gas Detector H 2 S CO O 2 SO 2 NH 3 PH 3 Cl 2 ClO 2 NO NO 2 HCN ETO O 3 Long-term solution Compact and affordable, the GasAlert Extreme reliably monitors for any single gas hazard within its wide range of available toxic gas models. With easy on/ off operation, this single gas detector offers extended longevity with a field-replaceable battery and sensor. A wide range of tamperproof user options and multilanguage display make the GasAlert Extreme an ideal solution for a variety of applications; plus, datalogging is now standard on all units. Calibration is a simple automatic procedure and is compatible with BW s MicroDock II automatic test and calibration system. Standard Package Contents Detector complete with specified sensor, stainless steel alligator clip and concussion-proof housing Calibration/test cap and hose Manual Multi-language CD manual General Specifications Size 1.1 x 2.0 x 3.75 in. / 2.8 x 5.0 x 9.5 cm Weight Typical battery life Certifications and approvals Warranty 2.9 oz. / 82 g 1.5 year battery life (typical) with replaceable 3V battery h Class I, Div. 1, Gr. A, B, C, D Class II, Div. 1, Gr. E, F, G American Bureau of Shipping ATEX: X g II 1 G Ex ia IIC T4 IECEx: Ex ia IIC T4 X: European Conformity Full two year warranty including sensors (One year Cl 2, NH 3, O 3, ETO & ClO 2 sensor) 5558-12 4 5062-24-NCL-BW-EN

* GasAlert Extreme Measuring Range Yellow Black Hydrogen sulfide (H 2 S) 0-100 ppm GAXT-H-DL GAXT-H-DL-B Hydrogen sulfide (H 2 S) (extended range) 0-500 ppm GAXT-H-2-DL GAXT-H-2-DL-B Carbon monoxide (CO) 0-1000 ppm GAXT-M-DL GAXT-M-DL-B Carbon monoxide (CO) (H 2 resistant) 0-1000 ppm GAXT-M2-DL GAXT-M2-DL-B Oxygen (O 2 ) 0-30.0% GAXT-X-DL-2 GAXT-X-DL-B-2 Sulfur dioxide (SO 2 ) 0-100 ppm GAXT-S-DL GAXT-S-DL-B Chlorine (Cl 2 ) 0-50.0 ppm GAXT-C-DL GAXT-C-DL-B Hydrogen cyanide (HCN) 0-30.0 ppm GAXT-Z-DL GAXT-Z-DL-B Nitrogen dioxide (NO 2 ) 0-99.9 ppm GAXT-D-DL GAXT-D-DL-B Ammonia (NH 3 ) 0-100 ppm GAXT-A-DL GAXT-A-DL-B Ammonia (NH 3 ) (extended range) 0-400 ppm GAXT-A2-DL GAXT-A2-DL-B Phosphine (PH 3 ) 0-5.0 ppm GAXT-P-DL GAXT-P-DL-B Ozone (O 3 ) 0-1 ppm GAXT-G-DL GAXT-G-DL-B Ethylene oxide (ETO) (C 2 H 4 O) 0-100 ppm GAXT-E-DL GAXT-E-DL-B Nitric oxide (NO) 0-250 ppm GAXT-N-DL GAXT-N-DL-B Chlorine dioxide (ClO 2 ) 0-1 ppm GAXT-V-DL GAXT-V-DL-B *Add -BR to the end of the order number for INMETRO certified detectors (for Brazil only). Gas Legend Cl 2 Chlorine NO Nitric oxide ClO 2 Chlorine dioxide NO 2 Nitrogen dioxide CO Carbon monoxide O 2 Oxygen ETO Ethylene oxide (C 2 H 4 O) O 3 Ozone H 2 S Hydrogen sulfide PH 3 Phosphine HCN Hydrogen cyanide SO 2 Sulfur dioxide NH 3 Ammonia MicroDock II Automatic test and calibration station (see MicroDock II section for additional information) IR DataLink GA-USB2 USB adaptor 5062-24-NCL-BW-EN To place an order, please contact BW Technologies by Honeywell (see back cover of this section for more information) 5

GasAlert Extreme SINGLE GAS DETECTOR Carrying Accessories Concussion-proof boot with stainless steel alligator-style clip Splash guard filters, kit of 5 for use with concussion-proof boot (GA-BALERT) Hard hat clip (non-conductive) Alligator-style clip (non-conductive) Alligator-style clip (stainless steel - included with detector ) Belt clip with screw Neck strap with safety release Short strap (6 in. / 15.2 cm) Extension strap (4 ft. / 1.2 m) Chest harness Hard-sided carrying case for motorized sampling pump and/or the detector Datalogging Accessories and Spares IR DataLink USB adaptor Sampling/Testing Equipment and Spares Test cap and hose (1 ft. / 0.3 m) replacement (included with detector) MicroDock II (not compatible with ClO 2 or O 3 ) - Base station plus GasAlert Extreme docking module - GasAlert Extreme docking module For complete MicroDock II system configuration information, see MicroDock II section. SamplerPak motorized sampling pack kit For a complete list of SamplerPak probes, hoses, accessories and spares, see SamplerPak section. Manual aspirator pump kit with probe (1 ft. / 0.3 m) Concussion-Proof Boot GA-BALERT GA-BALERT GA-BSPLASH-K GA-HC-1 GA-AG-1 GA-AG-2 GA-CL-1 GA-NS-1 GA-LY-1 GA-ES-1 GA-CH-2 SPAK-CC1 GA-USB2 GA-TC-1 DOCK2-2-1D-00-G DOCK2-0-1D-00-G Short Strap GA-LY-1 Neck strap GA-NS-1 GA-SPAK GA-AS02 Test Cap Replacement GA-TC-1 Splash Guard Filters GA-BSPLASH-K For concussion-proof boot 6 To place an order, please contact BW Technologies by Honeywell (see back cover of this section for more information) 5062-24-NCL-BW-EN

Power Spares Battery - lithium, 3V E2829 Sensor Spares and Replacements Replacement sensor screens with gasket, kit of 10 Replacement hydrogen sulfide (H 2 S) sensor Replacement carbon monoxide (CO) sensor Replacement carbon monoxide (CO) sensor, H 2 resistant Replacement oxygen (O 2 ) sensor For use with GAXT-X-DL-2 and GA-XT-DL-B-2 models. Replacement oxygen (O 2 ) sensor For use with GAXT-X-DL and GA-XT-DL-B models. Replacement sulfur dioxide (SO 2 ) sensor Replacement chlorine (Cl 2 ) sensor* Replacement hydrogen cyanide (HCN) sensor Replacement nitric oxide (NO) sensor Replacement nitrogen dioxide (NO 2 ) sensor Replacement ammonia (NH 3 ) sensor* Replacement ammonia (NH 3 ) sensor, extended range* Replacement phosphine (PH 3 ) sensor Replacement ozone (O 3 ) sensor* Replacement ethylene oxide (ETO) sensor* Replacement chlorine dioxide (ClO 2 ) sensor* GAXT-SS PS-RH04S PS-RM04 SR-M04-SC SR-X10-C1 SR-X10 PS-RS04 PS-RC10 PS-RZ10 SR-N04 PS-RD04 SR-A04 SR-A204 SR-P04 SR-G04 SR-E04 SR-V04 Note: All sensors come with a 2 year warranty unless marked with an asterisk (*), denoting 1 year warranty. Manual Aspirator Pump GA-AS02 Complete with probe, hose, aspirator pump and adaptor cap SamplerPak Kits Kits include motorized sampling pump, batteries and battery charger (if specified). See SamplerPak section for kit contents, accessories and spares; detector sold separately. Sensor Screens GAXT-SS 5062-24-NCL-BW-EN To place an order, please contact BW Technologies by Honeywell (see back cover of this section for more information) 7

GasAlert Extreme SINGLE GAS DETECTOR A D C B E F Note: Please refer to the instrument s documentation (shipped with the product or available at www.gasmonitors.com) for complete instructions on common service procedures. Improper servicing or maintenance may affect warranty eligibility. BW assumes no liability for damages resulting from improper servicing or maintenance. 8 To place an order, please contact BW Technologies by Honeywell (see back cover of this section for more information) 5062-24-NCL-BW-EN

Service Parts Legend Replacement back enclosure (yellow) Replacement back enclosure (black) Replacement front enclosure (yellow) Replacement front enclosure (black) Replacement PCB, ammonia (NH 3 ), extended range, datalogging version Replacement PCB, ammonia (NH 3 ), extended range Replacement PCB, ammonia (NH 3 ) Replacement PCB, chlorine (Cl 2 ) Replacement PCB, nitrogen dioxide (NO 2 ) Replacement PCB, ethylene oxide (ETO) Replacement PCB, ozone (O 3 ) Replacement PCB, hydrogen sulfide (H 2 S) Replacement PCB, hydrogen sulfide (H 2 S), extended range Replacement PCB, carbon monoxide (CO), H 2 resistant Replacement PCB, carbon monoxide (CO) Replacement PCB, nitric oxide (NO) Replacement PCB, phosphine (PH 3 ) Replacement PCB, sulfur dioxide (SO 2 ) Replacement PCB, chlorine dioxide (ClO 2 ) Replacement PCB, oxygen (O 2 ) Replacement PCB, hydrogen cyanide (HCN) Replacement bubble label, hydrogen sulfide (H 2 S) Replacement LCD holder with light pipe Replacement LCD GAXT-BC1 GAXT-BC1B GAXT-FC1 GAXT-FC1B GAXT-A2-DL-PCB1 GAXT-A2-PCB1 GAXT-A-DL-PCB1 GAXT-C-DL-PCB1 GAXT-D-DL-PCB1 GAXT-E-DL-PCB1 GAXT-G-DL-PCB1 GAXT-H-DL-PCB1 GAXT-H-2-DL-PCB1 GAXT-M2-DL-PCB1 GAXT-M-DL-PCB1 GAXT-N-DL-PCB1 GAXT-P-DL-PCB1 GAXT-S-DL-PCB1 GAXT-V-DL-PCB1 GAXT-X-DL-PCB1 GAXT-Z-DL-PCB1 GAXT-H-BLABEL GAXT-HLCD GAXT-LCD A B C How to Replace the Battery 1. With monitor OFF, use No. 1 Phillips screwdriver to remove 4 screws from back enclosure (A) 2. Lift back enclosure (A) straight up 3. Lift battery (D) straight up 4. Insert new battery (D) 5. Replace back enclosure (A) 6. Replace 4 screws in back enclosure (A) and hand-tighten until firm How to Replace the Sensor 1. With monitor OFF, use No. 1 Phillips screwdriver to remove 4 screws from back enclosure (A) 2. Lift back enclosure (A) straight up 3. Use No. 1 Phillips screwdriver to remove 2 screws from the back of the PCB (C) 4. Lift PCB (C) together with battery (D) and sensor (E) straight up 5. Remove sensor (E) from PCB (C) by pulling straight up 6. Insert new sensor (E) into PCB (C) 7. Replace PCB (C) and 2 screws and hand-tighten until firm 8. Replace back enclosure (A) 9. Replace 4 screws in back enclosure (A) and hand-tighten until firm How to Replace the Sensor Screen 1. With monitor OFF, use No. 1 Phillips screwdriver to remove 4 screws from back enclosure (A) 2. Lift back enclosure (A) straight up 3. Use No. 1 Phillips screwdriver to remove 2 screws from the back of the PCB (C) 4. Lift PCB (C) together with battery (D) and sensor (E) straight up 5. Remove sensor screen (F) from front enclosure (B) by pulling straight up 6. Insert new sensor screen (F) into front enclosure (B) 7. Replace board (C) and 2 screws and hand-tighten until firm 8. Replace back enclosure (A) 9. Replace 4 screws in back enclosure (A) and hand-tighten until firm Note: Please refer to the instrument s documentation (shipped with the product or available at www.gasmonitors.com) for complete instructions on common service procedures. Improper servicing or maintenance may affect warranty eligibility. BW assumes no liability for damages resulting from improper servicing or maintenance. 5062-24-NCL-BW-EN To place an order, please contact BW Technologies by Honeywell (see back cover of this section for more information) 9