Dosimeters/Survey meters 40 Gracechurch Str., EC3V OBT, London, United Kingdom (24 Hour Customer Line) 0044 208 720 6926
RAD-ION (RI-02) Especially designed for the Detection of Pulsed (Golden Engineering) X-ray Energy The RAD- ION is the next generation ion chamber survey meter. This smart meter features accurate rate & dose measurements World class solution for use in nuclear Power plants, Nuclear medicine, Radiography, Life science, Research and other industrial applications. Provides highly stable and accurate measurement of dose rates and integrated dose of gamma, x- ray and beta radiation. Provides accurate readings as low as 60 nanosecond X- Ray bursts as emitted by pulsed X- ray Generators (Golden Engineering)
RAD-ION (RI-02) Features Large visible characters and numbers via LCD display 4 Touch pad buttons Beta slide window Icon identification differentiating between Gamma and Gamma Beta readings. Beta correction factor Automatic offset zeroing function Calibration mode Data storage Integrated Dose mode
Applications: Gamma and X- ray and Pulsed X- ray exposure survey meter with beta response Range: 0.00 usv/h to 1 Sv/h (0.00 mr/h to 100 R/h) Measuring: 1 usv/h to 1 Sv/h ( 0.1 mr/h to 100 R/h) Dose (D&M): Up to 10 Sv (1000 R) Energy Response: From 20 kev to 2 MeV Chamber Volume: 350 cm³ Side Wall: Plastic 300 mg/cm² ; Al 1000 mg/cm² available upon request Beta Shield: Retractable 1000 mg/cm² aluminum slide Window: 7 mg/cm² mylar/cloth material Window Area: 50 cm² (7.8 in²) Temperature Range: - 10 C to 50 C (23 F to 122 F) Display: multi- segments, liquid Crystal display with LED backlight Push buttons: 4 push buttons, simple operation Power: 2 each C cell batteries housed in a sealed externally accessible compartment
RAM-ION Especially designed for the Detection of Pulsed (Golden Engineering) X-ray Energy Battery operated, Auto ranging, Portable ion chamber Survey meter designed for highly stable and accurate measurements of dose rates and integrated dose of gamma, x- ray and beta radiation The auto ranging meter utilizes a combination display consisting of a smoothed digital readout for minimum fluctuation and a two decade analog bar graph for fast response Compact, hand- held, lightweight, rugged, easy to use and maintain
The RAM-ION Provides a straightforward, fast and reliable method of collecting and storing monitoring data on site for later use. Reads bar code labels that identify measurements location. The measurement's data combined with their locations, data and time are stored in a built- in memory. The stored data records can be downloaded by the SMARTS software packages. Ideal for use in nuclear power plants, nuclear medicine, radiography and radiotherapy facilities, life science laboratories, nuclear research centers and in other industrial applications
Ion chamber survey meter Highest safety: provides accurate readings as low as 60 nanosecond X- Ray bursts as emitted by pulsed X- ray Generators (Golden Engineering) Wide measuring range of 1µSv/hr to 500mSv/hr (0.1 mr/hr to 50 /hr) Built in memory to store data Dose rate and accumulated dose measurement Display illumination Freeze mode to record the highest dose User programmable dose rate and accumulated dose alarms Remote PC communication Hot Spot detection RAM-ION Main Features
RAM-ION Technical Data Measuring Range 1µSv/hr to 500mSv/hr (0.1 mr/hr to 50R/hr) Display Range 0.1µSv/hr to 500mSv/hr (0.01 mr/hr to 50R/hr) Accuracy ±10% of reading within measuring range Gamma Energy Dependence (137Cs) Better than ±20% at 20keV to 1.3MeV Angular Dependence (137Cs) Ion Chamber Volume Chamber Wall and Cover Thickness Window Thickness Response Time Less than ±5% (for ±120o of front direction 500 cc 300mg/cm2 (tissue equivalent) 7 mg/cm2 2 sec. for readings above 1 mr/h 5 sec. for auto- ranging change, from Low Range to High _Range (2sec. +3 additional seconds for auto ranging delay) Power Source (Built in automatic battery check) meter: two 1.5V C- type Alkaline cells - 100 hours of continuous operation laser scanner: One 9V Alkaline cell - 6000 operations Display Data Logging Temperature Range DigiLog (3 digits and 2 decades of analog bar graph) 347 data records (1415 with extended memory) Operation - 10oC to +50oC (15oF - 122oF) Storage: - 20oC to +60oC (- 5oF - 140oF) Humidity Range Up to 95% RH (non condensing) Dimensions Width: 10cm (3.9"), length 25cm (9.8"), height 19cm (7.5") Weight 1100g (2.4lb) Casing High impact ABS
The DMC 3000 - Personal Electronic Dosimeter The DMC 3000 covers a wide range of X- Ray and Gamma radiation detection fields from 15keV to 7Mev and linear response to dose rate fields from natural background up to more than 10 Sv/h. The pass- by data exchange feature gives unequal operational flexibility. In- motion reading allows dose management by sub- zone as well as real- time location tracking of personnel.
DMC 3000 Features Loud alarm, 85 db (A) typical, (> 90 db (C) peak) Vibrating alarm Highly visible backlit display Optional telemetry module Factory upgradeable firmware Simple 2- button navigation Extended dose rate alarms Dual ultra bright LED alarm Superior X- ray and gamma energy response Meets or exceeds applicable IEC and ANSI standards Designed with ruggedness and durability in mind
DMC 3000 - Technical Specifications Radiological Characteristics Compliant with IEC 61526Ed. 3, ANSI 42.20 Isotropy 241Am and 137Cs with ± 75 angle Measurement and display Energy response better than ± 20% (typically ± 10%) Accuracy Hp(10): ± 10%* (137Cs, ~ 24 msv/h); ± 15%*, (241Am, ~ 23 msv/h); ± 19%** X- ray 16keV (*including ± 5% extended uncertainty k=2); (** including ± 9% extended uncertainty k=2) Display dose: 1 µsv to 10 Sv (0.1 mrem to 1000 rem) Display rate: 10 µsv/h to 10 Sv/h (1 mrem/h to 1000 rem/h) or 1 µsv/h to 10Sv/h (0.1 mrem/h to 1000 rem/h) extended option. Dose Rate Linearity: < ± 20% up to 10 Sv/h (1000 rem/h) (Co and X H30 20 kev); < ± 20% up to 6 Sv/h (600 rem/h) (Pulsed X- rays 20 ms width, 1, 10 & 20 pps)
Electrical Characteristics Standard AAA (LR03) 1.5 V Alkaline battery 9 calendar month battery life (typical, 8 h per day, 5 days per week in run mode, without excessive alarms)* 2500 h battery life in continuous run, without excessive alarm Mechanical Characteristics DMC 3000 - Technical Specifications Rugged, high impact polycarbonate- ABS case Dimensions: 86 x 56 x 21 mm (3.4 x 2.2 x 0.8 in) without clip Weight with alkaline battery and clip: < 88 g (3.1 oz) Worn by a replaceable clips (2 different style back clips or one a front- facing clip for DMC worn inside the pocket)
DMC 3000 - Technical Specifications Environmental Characteristics Temperature range: - 10 C to 50 C (14 F to 122 F):deviation in response less than ± 5% Relative humidity: < 90% at 42 C (108 F) Storage: - 20 C to 71 C (- 4 F to 160 F) Shock, vibration and drop resistant (1.5 meter on concrete) Waterproof IP67: 1m (39 in) during 1 hour EMC: complies and exceeds standards by a large margin (Compliant, certificate number: 53720) MIL STD 461F RS103 (pulsed electric field): exceeds 200 V/m from 30 khz to 5GHz MIL STD 461F RS101 (magnetic field 30 Hz - 100 khz)
LDM-320 - USB Dosimeter Reader The LDM 320D and LDM 320W readers operate using software packages installed on computer (PC) and communicates with DMC 3000 dosimeter and DMC 2000 and SOR families in hands- free data exchange mode. The LDM 320 reader is used as an interface to activate a dosimeter (to switch into a counting mode) or to deactivate it (to switch into pause mode). When used by the included DMCUser software, it functions as an interface to read and write the internal data of the DMC 3000, SOR and DMC 2000 dosimeters
LDM-320 - USB Dosimeter Reader Compact and low- cost Hands- free communication with dosimeters No directional alignment required 3 Indicator LEDs for operation and access control Manageable digital inputs/outputs DSP based digital process Compatible with the DMC 2000 and SOR families, ipam- Tx as well as the DMC- 3000dosimeter Compatible with software packages: DOSICARE, DOSIFAST, DMCUser and LDM 3000SW Wall- mounted or desk versions
LDM-320 Technical Specifications Mechanical Characteristics: Length: 109 mm (4.3 in) Width: 100 mm (3.9 in) Depth: 29 mm (1.1 in) Weight: 150 gr (5.3 Oz) Environmental Characteristics: Operating temperature: 0 C to +50 C (32 F to 122 F) Storage temperature: - 10 C to +60 C (+14 F to 140 F) Humidity: 90% HR (without condensation) IP LDM 320D: IP52
PDS-GO Personal Radiation Detector Small, lightweight (125 g), sensitive, personal gamma radiation detector Meets ANSI N42.32 & 42.33 requirements Designed using the latest state- of- the- art electronic components including the advanced technology of Silicon photomultiplier as a detector. Especially useful for professionals dealing in safety and security of sensitive installations, public areas and border control. Easily carried on the body and is used to detect the presence and magnitude of gamma emitting radiation.
PDS-GO Personal Radiation Detector CsI(Tl) scintillation crystal for high efficiency to extended energy range Excellent sensitivity to ANSI source strength Excellent temperature stability Two operation modes (Detect/Search) Low power consumption extended operating hours Instrument setup (alarm thresholds and other parameters) via USB connection to a PC using user- friendly software application. Record of event history Rechargeable battery charging via USB connection Accessories include protective silicon cover, belt clip, charging cradle, USB cable
PDS-GO Technical Specifications
RAM GENE-1 mark II Designed for work in extreme conditions Features a ruggedized casing, backlight and a specially designed energy filter embedded in the cap for dose rate radiation monitoring according to Ambient Dose Equivalent, with the additional flexibility of a contamination meter Equipped with a recessed, internal GM pancake detector using a thin mica window protected by a stainless steel screen The transition between measuring dose rate radiation and contamination is achieved by simply removing or placing the plastic cap
RAM GENE-1 mark II Features Large, four digit, continuous ranging, LCD display Simple, three key Features operation Large 1.75" pancake GM detector Suitable for alpha, beta or gamma contamination detection Unit readouts of count rate (CPS in contamination mode and µsv/hr in dose mode). Audible and visual (LED) count rate indication Smart software provides fast, yet stable response Dead time correction Alarms for overflow, low battery and detector failure Automatic self diagnostic routines Durable case with splash resistant keypad
RAM GENE-1 mark II Specifications Display: Large, four digit, continuous ranging LCD readout for display of count rate, dose rate, overflow, low battery, and detector failure. LED: Flashing count rate indication with Audio Piezo electric element synchronized with count LED. Units: Counts per second (CPS) or counts per minute (CPM) and µsv/hr or mr/hr. Controls: Three key keypad with positive feedback for ON/OFF Key combinations for selecting count rate or dose rate unit displays. Power: Standard 9V alkaline battery - provides approximately 50 hours continuous use with speaker off. Automatic battery check under full load. Detector: 1.75" Pancake GM tube - LND73118 or equivalent Window : Mica, 1.5-2.0 mg/cm2 protected by stainless steel mesh. Count Range: 0-42,000 cps Sensitivity: Approximately 5.8 cps/µsv/hr (58 cps/mr/hr) - 137Cs Measuring Range: 0.05µSv/hr to 7mSv/hr (5µR/hr to 700mR/hr) Display Resolution: 0.01µSv/hr (0.001mR/hr) Background: 0-1 cps Temperature Range: Operation: - 10oC to +50oC (15oF to 122oF) Storage: - 20oC to +60oC (- 5oF to 140oF) Humidity Range: 40% to 95% RH (non condensing) Case: High impact ABS Dimensions: 11.4cm *7.2cm *6.7cm (4.5" x 2.8" x 2.6") (including Detector) Weight: 560 gram (1.23 lbs) (including battery)
RAM GAM-1 Gamma Survey Meter with state of the art microprocessor Compact, portable, lightweight designed for single- handed operation Offers optimal performance and is ideal for maintaining the highest safety standards in various applications
RAM GAM-1 Features Large, four digit, continuous ranging, LCD display Simple, three key operation Readout of dose rate and accumulated dose Units of either mr or µsv Programmable alarm thresholds Audible and visual (LED) count rate indication Smart software provides fast, yet stable response Dead time correction Alarms for detector overflow, low battery and detector failure Automatic self diagnostic routines Durable case with splash resistant keypad
RAM GAM-1 Specifications Display: LED: Audio: Units: Controls: Power Source: Detector: Measuring Range: Large, four digit, continuous ranging, LCD readout for display of accumulated dose, dose rate, alarm threshold value, overflow, low battery, and detector failure Flashing count rate indication Piezo electric element synchronised with count LED mr and mr/hr or µsv and µsv/hr Three key keypad with positive feedback for ON/OFF, RESET and SPEAKER. Key combinations for selecting accumulated dose and threshold displays Standard 9V alkaline battery - provides approximately 50 hours continuous use with speaker off. Automatic battery check under full load. Energy compensated GM tube - ZP1201 or equivalent 0.05mR/hr to 999mR/hr (0.5µSv/hr to 9999µSv/hr) Display Range: Sensitivity: Accuracy: Energy Range: Energy Dependence: Angular Dependence: 0.05mR/hr to 999mR/hr (0.5µSv/hr to 9999µSv/hr) 17 cps/mr/hr (137Cs) ±15% of reading within measuring range 50keV to 2.0 MeV ±20% related to 137Cs Less than ±20% for ±45o of preferred direction Temperature Range: Operation: -10oC to +50oC (15oF to 122oF) Storage: -20oC to +60oC (-5oF to 140oF) Humidity Range: 40% to 95% RH (non condensing) Case: High impact ABS Dimensions: 13cm x 7.2cm x 3.4cm (5.12" x 2.83" x 1.34") Weight: 0.280 Kg (0.62 lbs)
DRM Data Radiation Monitor The DRM- 2 is a GM tube- based wide range Area Monitor designed specifically to be used as a fixed monitor in varying dose rate fields using two very sensitive, auto switching GM tubes. The DRM s detector features a linear response from 0.1µSv/h to 10Sv/h (10uR/h to 1000R/h). Wall- mounted instrument that can be connected to AC power with NiMH backup batteries. The radiation data is sent via 900 MHz FHSS or 2.4 GHz FHSS radios to a transceiver or via hardwire (RS- 232 or RS- 485) to a Remote Monitoring System. The DRM- 2 can also be connected directly to a computer input.
DRM Applications Perimeter or boundary surveillance The DRM is a portable or fixed position device used for perimeter and/or boundary monitoring used to quickly identify changing radiological conditions. Collection of radiological survey data for real- time mapping and surveillance software The DRM provides live radiological data for display, archiving and trending in real- time mapping software programs (e.g. TeleMap).
DRM Features Readout of dose rate and accumulated dose Ruggedized construction, metal casing User- selectable internal alarm threshold Built- in RS- 232/RS- 485 communication connection for use with Area Monitor or WRM transmitter. Output plug for Local Alarm Unit. Calibration software (optional) Dead time correction Alarms for detector overflow, low battery and detector failure Automatic self diagnostic routines RADNET and CE compatible
DRM Specifications Measuring Range: Sensitivity: Accuracy: Units: Power Source: Temperature Range : 0.1. µsv/hr to 10Sv/hr (10µR/hr -1000R/hr) 0.3cps/mR/hr (137 Cs) ±10 % of reading within measuring range µsv and µsv/hr or mr and mr/hr External AC Power backed up by two NiMH batteries Operation: -10oC to +50oC (15oF to 122oF) Storage: -20oC to +60oC (-5oF to 140oF) Humidity Range : Case: 40% to 95% RH (non condensing) Blue anodized aluminum Dimensions: 93mm W x 148mm L x 56mm H (3.7 " x 5.8 " x 2.2 ") Weight: Radio Frequencies: 680g (1.5 lbs) 900 MHz FHSS or 2.4 GHz FHSS