Dosimeters/Survey meters

Similar documents
RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009

DMC 3000 User s Guide

RAM GENE / RAM GENE-1

DMC 3000 Quick User s Guide

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

Using the GammaRAE II Responder Personal Radiation Detector and Dosimeter in One. Firmware Version 3.00 D August 2006

User s Manual. Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30. Fuji Electric Co., Ltd. TN514629i 1/31

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017

DMC 2000 Personal Electronic Dosimeter

LUDLUM MODEL 25 AND 25-1 PERSONAL RADIATION MONITOR USER S MANUAL. October 2014 Serial Number and Succeeding Serial Numbers

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

Nuclear Associates

Portable Survey Instruments NISP-RP-01

Area Monitor/Frisker Count Rate Meter Victoreen

Contamination Meter Users Manual

Our Extended Personal Electronic Dosimeter (PED) Family

DIGITAL AREA RADIATION MONITOR

PRD Domestic Price List

AM-806. Waste/Door Radiation Monitor OPERATIONS MANUAL

Radiation Alert Frisker INTERNATIONAL

RAD-60 USER GUIDE (ALSO FOR THE RAD-50 MODEL AND ISOTRAK DOSIMETERS)

LUDLUM MODEL 3276 SERIES FRISKER/AREA MONITOR USER S MANUAL. November 2017 Serial Number: and Succeeding Firmware: 49830n30 and Higher

910A DOSIMETER CHARGER, AC-POWERED

Identify the following features and specifications for the ESP1

Using the GammaRAE II Personal Radiation Detector

Kata products Kata DGM-1500 Turva

RAM GAM-1C Gamma Survey Meter TYPE TEST

Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter

LUDLUM MODEL 26-1 FRISKER USER S MANUAL. April 2017 Serial Number PF and Succeeding Serial Numbers

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

minidose A compact and colorful personal electronic dosimeter, your family can use everyday.

PORTABLE or FIXED PERSONNEL & VEHICLE MONITOR

Ranger EXP RADIATION A L E R T

AERIAL RADIATION DETECTORS

LUDLUM MODEL and PANCAKE CLUSTER DETECTORS. June 2016

LUDLUM MODEL AND LUDLUM MODEL ALPHA, BETA, & GAMMA DETECTORS

Radiation Monitoring Systems

TRACERCO T402 and T402HR USER MANUAL

Products & Solutions for Military Customers

POSITRON EMISSION TOMOGRAPHY (PET) CENTER MONITORS

LUDLUM MODEL 44-9 ALPHA, BETA, GAMMA DETECTOR. February 2010 Serial Number PR and Succeeding Serial Numbers

Electronic Personal Dosemeter

Detecting Radiation. Protection through Detection. February Animations in this training work best in Windows XP

Radioactivity dosimeter RD01. User's Manual

CONTAMINATION MONITORING INSTRUMENTATION RCT STUDY GUIDE LEARNING OBJECTIVES:

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

RadEye N / NL Personal Highly Sensitive Neutron Radiation Detector

Advanced Radiation Detection Equipment

Radiation Safety. Product Catalog 2011/2012. Better products. More choices. One company. Fluke Biomedical.

Personal Radiation Alarm Dosimeter LK Operating Instruction Manual. Contents

Setting the new standard for personal radiation detection.

Using ALARA Technologies to Solve Everyday HP Challenges

AERIAL RADIATION & CHEMICAL DETECTION SYSTEM. DroneSENSOR TM Series. Particulate Alpha, Beta, Gamma & Airborne Chemicals

MetRad1 Handheld Metal/Gamma Detection Unit. Operation Manual. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since 1963 BNC

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020

PM1703MO-1A PM1703MO-1B PERSONAL COMBINED RADIATION DETECTOR/DOSIMETER. Operation Manual

RIID capability in the palm of your hand

Turnkey Solutions for Radiation Protection in PET Laboratories R A D I A T I O N P R O T E C T I O N

LUDLUM MODEL 26 FRISKER USER S MANUAL. December 2016 Serial Number PF and Succeeding Serial Numbers

LUDLUM MODEL RK2 RESPONSE KIT. October 2017 Serial Number and Succeeding Serial Numbers

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

GasAlertMicroClip X3 Specifications

LUDLUM MODEL ALPHA, BETA, GAMMA HAND DETECTOR. June 2016 Serial Number and Succeeding Serial Numbers

Radiation Safety. Product Catalog 2007/2008. Fluke Biomedical. The accuracy you need from a company you can trust.

WIDE SEARCH AREA HAND-HELD METAL DETECTION SET

TRACERCO Radiation Monitor

PRELIMIN INTERNATIONAL

RADCOMM RADIATION DETECTION SYSTEMS. Leading Supplier of Innovative Radiation Detection Systems.

LUDLUM MODEL RK RESPONSE KIT. January 2016 Serial Number and Succeeding Serial Numbers

Nardalert S3 TM Non-Ionizing Radiation Monitor

TRACERCO Radiation Monitor. Instruction and Maintenance Manual for Model No. T202

DOE 2.17 Contamination Monitoring Instrumentation Study Guide. 00ICP330 Rev. 0 Page 1 of 23

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor

CEIA THS 21 series INDUSTRIAL METAL DETECTION SYSTEMS. Superior Detection Capabilities. Maximum Configurability

LUDLUM MODEL 44-7 Alpha, Beta, Gamma Detector. July 2012 Serial No. PR and succeeding Serial Numbers

Surface Contamination Monitor. Operation Manual

Portable Instruments For First Response & In-Situ Analysis of Radiation

RadEye B20 RadEye B20-ER Multi-Purpose Survey Meter

GRAPPLE SCANNER FOR RADIATION IN SCRAP METAL. Model Series ~ GRAPPLE SCAN- GR Models ~ GRAPPLE SCAN- GR-A, -B, -C, & -D

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

DSP EC Pro. Advanced, Digital Gamma-Ray Spectrometer for HPGe Detector Systems

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

LUDLUM MODEL 44-2 GAMMA SCINTILLATOR. February 2018 Serial Number PR and Succeeding Serial Numbers

FLX380-30x FlexTester OTDR

Controls Surface mounted pushbuttons Suitable for gloved use. Buttons Side - On/Off Front Menu Scroll Pin Hole Setup access

MeshGuard and MeshGuard Gamma

NEW GENERATION COMPACT HAND HELD METAL DETECTION SET

PD240 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET FEATURES

For the Safety of Your

MODEL 951 RADIATION DETECTOR

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

LUDLUM MODEL 35 SERIES DIGITAL SURVEY METER USER S MANUAL

stationary dose rate measuring systems

SVG 2 and Probes. Innovation with Integrity. The new Generation of Semiconductor Radiation Meters and Handheld Radiation Detection Probes

EasyLog Data Logger Series

ALTAIR 5X Multigas Detector Product Specification

MicroRay IR-100 NEW. Inspection MicroRay IR-100

The system can be easily relocated by a standard container truck., and re-commissioned by trained engineers typically within a 72-hour period

Transcription:

Dosimeters/Survey meters 40 Gracechurch Str., EC3V OBT, London, United Kingdom (24 Hour Customer Line) 0044 208 720 6926

RAD-ION (RI-02) Especially designed for the Detection of Pulsed (Golden Engineering) X-ray Energy The RAD- ION is the next generation ion chamber survey meter. This smart meter features accurate rate & dose measurements World class solution for use in nuclear Power plants, Nuclear medicine, Radiography, Life science, Research and other industrial applications. Provides highly stable and accurate measurement of dose rates and integrated dose of gamma, x- ray and beta radiation. Provides accurate readings as low as 60 nanosecond X- Ray bursts as emitted by pulsed X- ray Generators (Golden Engineering)

RAD-ION (RI-02) Features Large visible characters and numbers via LCD display 4 Touch pad buttons Beta slide window Icon identification differentiating between Gamma and Gamma Beta readings. Beta correction factor Automatic offset zeroing function Calibration mode Data storage Integrated Dose mode

Applications: Gamma and X- ray and Pulsed X- ray exposure survey meter with beta response Range: 0.00 usv/h to 1 Sv/h (0.00 mr/h to 100 R/h) Measuring: 1 usv/h to 1 Sv/h ( 0.1 mr/h to 100 R/h) Dose (D&M): Up to 10 Sv (1000 R) Energy Response: From 20 kev to 2 MeV Chamber Volume: 350 cm³ Side Wall: Plastic 300 mg/cm² ; Al 1000 mg/cm² available upon request Beta Shield: Retractable 1000 mg/cm² aluminum slide Window: 7 mg/cm² mylar/cloth material Window Area: 50 cm² (7.8 in²) Temperature Range: - 10 C to 50 C (23 F to 122 F) Display: multi- segments, liquid Crystal display with LED backlight Push buttons: 4 push buttons, simple operation Power: 2 each C cell batteries housed in a sealed externally accessible compartment

RAM-ION Especially designed for the Detection of Pulsed (Golden Engineering) X-ray Energy Battery operated, Auto ranging, Portable ion chamber Survey meter designed for highly stable and accurate measurements of dose rates and integrated dose of gamma, x- ray and beta radiation The auto ranging meter utilizes a combination display consisting of a smoothed digital readout for minimum fluctuation and a two decade analog bar graph for fast response Compact, hand- held, lightweight, rugged, easy to use and maintain

The RAM-ION Provides a straightforward, fast and reliable method of collecting and storing monitoring data on site for later use. Reads bar code labels that identify measurements location. The measurement's data combined with their locations, data and time are stored in a built- in memory. The stored data records can be downloaded by the SMARTS software packages. Ideal for use in nuclear power plants, nuclear medicine, radiography and radiotherapy facilities, life science laboratories, nuclear research centers and in other industrial applications

Ion chamber survey meter Highest safety: provides accurate readings as low as 60 nanosecond X- Ray bursts as emitted by pulsed X- ray Generators (Golden Engineering) Wide measuring range of 1µSv/hr to 500mSv/hr (0.1 mr/hr to 50 /hr) Built in memory to store data Dose rate and accumulated dose measurement Display illumination Freeze mode to record the highest dose User programmable dose rate and accumulated dose alarms Remote PC communication Hot Spot detection RAM-ION Main Features

RAM-ION Technical Data Measuring Range 1µSv/hr to 500mSv/hr (0.1 mr/hr to 50R/hr) Display Range 0.1µSv/hr to 500mSv/hr (0.01 mr/hr to 50R/hr) Accuracy ±10% of reading within measuring range Gamma Energy Dependence (137Cs) Better than ±20% at 20keV to 1.3MeV Angular Dependence (137Cs) Ion Chamber Volume Chamber Wall and Cover Thickness Window Thickness Response Time Less than ±5% (for ±120o of front direction 500 cc 300mg/cm2 (tissue equivalent) 7 mg/cm2 2 sec. for readings above 1 mr/h 5 sec. for auto- ranging change, from Low Range to High _Range (2sec. +3 additional seconds for auto ranging delay) Power Source (Built in automatic battery check) meter: two 1.5V C- type Alkaline cells - 100 hours of continuous operation laser scanner: One 9V Alkaline cell - 6000 operations Display Data Logging Temperature Range DigiLog (3 digits and 2 decades of analog bar graph) 347 data records (1415 with extended memory) Operation - 10oC to +50oC (15oF - 122oF) Storage: - 20oC to +60oC (- 5oF - 140oF) Humidity Range Up to 95% RH (non condensing) Dimensions Width: 10cm (3.9"), length 25cm (9.8"), height 19cm (7.5") Weight 1100g (2.4lb) Casing High impact ABS

The DMC 3000 - Personal Electronic Dosimeter The DMC 3000 covers a wide range of X- Ray and Gamma radiation detection fields from 15keV to 7Mev and linear response to dose rate fields from natural background up to more than 10 Sv/h. The pass- by data exchange feature gives unequal operational flexibility. In- motion reading allows dose management by sub- zone as well as real- time location tracking of personnel.

DMC 3000 Features Loud alarm, 85 db (A) typical, (> 90 db (C) peak) Vibrating alarm Highly visible backlit display Optional telemetry module Factory upgradeable firmware Simple 2- button navigation Extended dose rate alarms Dual ultra bright LED alarm Superior X- ray and gamma energy response Meets or exceeds applicable IEC and ANSI standards Designed with ruggedness and durability in mind

DMC 3000 - Technical Specifications Radiological Characteristics Compliant with IEC 61526Ed. 3, ANSI 42.20 Isotropy 241Am and 137Cs with ± 75 angle Measurement and display Energy response better than ± 20% (typically ± 10%) Accuracy Hp(10): ± 10%* (137Cs, ~ 24 msv/h); ± 15%*, (241Am, ~ 23 msv/h); ± 19%** X- ray 16keV (*including ± 5% extended uncertainty k=2); (** including ± 9% extended uncertainty k=2) Display dose: 1 µsv to 10 Sv (0.1 mrem to 1000 rem) Display rate: 10 µsv/h to 10 Sv/h (1 mrem/h to 1000 rem/h) or 1 µsv/h to 10Sv/h (0.1 mrem/h to 1000 rem/h) extended option. Dose Rate Linearity: < ± 20% up to 10 Sv/h (1000 rem/h) (Co and X H30 20 kev); < ± 20% up to 6 Sv/h (600 rem/h) (Pulsed X- rays 20 ms width, 1, 10 & 20 pps)

Electrical Characteristics Standard AAA (LR03) 1.5 V Alkaline battery 9 calendar month battery life (typical, 8 h per day, 5 days per week in run mode, without excessive alarms)* 2500 h battery life in continuous run, without excessive alarm Mechanical Characteristics DMC 3000 - Technical Specifications Rugged, high impact polycarbonate- ABS case Dimensions: 86 x 56 x 21 mm (3.4 x 2.2 x 0.8 in) without clip Weight with alkaline battery and clip: < 88 g (3.1 oz) Worn by a replaceable clips (2 different style back clips or one a front- facing clip for DMC worn inside the pocket)

DMC 3000 - Technical Specifications Environmental Characteristics Temperature range: - 10 C to 50 C (14 F to 122 F):deviation in response less than ± 5% Relative humidity: < 90% at 42 C (108 F) Storage: - 20 C to 71 C (- 4 F to 160 F) Shock, vibration and drop resistant (1.5 meter on concrete) Waterproof IP67: 1m (39 in) during 1 hour EMC: complies and exceeds standards by a large margin (Compliant, certificate number: 53720) MIL STD 461F RS103 (pulsed electric field): exceeds 200 V/m from 30 khz to 5GHz MIL STD 461F RS101 (magnetic field 30 Hz - 100 khz)

LDM-320 - USB Dosimeter Reader The LDM 320D and LDM 320W readers operate using software packages installed on computer (PC) and communicates with DMC 3000 dosimeter and DMC 2000 and SOR families in hands- free data exchange mode. The LDM 320 reader is used as an interface to activate a dosimeter (to switch into a counting mode) or to deactivate it (to switch into pause mode). When used by the included DMCUser software, it functions as an interface to read and write the internal data of the DMC 3000, SOR and DMC 2000 dosimeters

LDM-320 - USB Dosimeter Reader Compact and low- cost Hands- free communication with dosimeters No directional alignment required 3 Indicator LEDs for operation and access control Manageable digital inputs/outputs DSP based digital process Compatible with the DMC 2000 and SOR families, ipam- Tx as well as the DMC- 3000dosimeter Compatible with software packages: DOSICARE, DOSIFAST, DMCUser and LDM 3000SW Wall- mounted or desk versions

LDM-320 Technical Specifications Mechanical Characteristics: Length: 109 mm (4.3 in) Width: 100 mm (3.9 in) Depth: 29 mm (1.1 in) Weight: 150 gr (5.3 Oz) Environmental Characteristics: Operating temperature: 0 C to +50 C (32 F to 122 F) Storage temperature: - 10 C to +60 C (+14 F to 140 F) Humidity: 90% HR (without condensation) IP LDM 320D: IP52

PDS-GO Personal Radiation Detector Small, lightweight (125 g), sensitive, personal gamma radiation detector Meets ANSI N42.32 & 42.33 requirements Designed using the latest state- of- the- art electronic components including the advanced technology of Silicon photomultiplier as a detector. Especially useful for professionals dealing in safety and security of sensitive installations, public areas and border control. Easily carried on the body and is used to detect the presence and magnitude of gamma emitting radiation.

PDS-GO Personal Radiation Detector CsI(Tl) scintillation crystal for high efficiency to extended energy range Excellent sensitivity to ANSI source strength Excellent temperature stability Two operation modes (Detect/Search) Low power consumption extended operating hours Instrument setup (alarm thresholds and other parameters) via USB connection to a PC using user- friendly software application. Record of event history Rechargeable battery charging via USB connection Accessories include protective silicon cover, belt clip, charging cradle, USB cable

PDS-GO Technical Specifications

RAM GENE-1 mark II Designed for work in extreme conditions Features a ruggedized casing, backlight and a specially designed energy filter embedded in the cap for dose rate radiation monitoring according to Ambient Dose Equivalent, with the additional flexibility of a contamination meter Equipped with a recessed, internal GM pancake detector using a thin mica window protected by a stainless steel screen The transition between measuring dose rate radiation and contamination is achieved by simply removing or placing the plastic cap

RAM GENE-1 mark II Features Large, four digit, continuous ranging, LCD display Simple, three key Features operation Large 1.75" pancake GM detector Suitable for alpha, beta or gamma contamination detection Unit readouts of count rate (CPS in contamination mode and µsv/hr in dose mode). Audible and visual (LED) count rate indication Smart software provides fast, yet stable response Dead time correction Alarms for overflow, low battery and detector failure Automatic self diagnostic routines Durable case with splash resistant keypad

RAM GENE-1 mark II Specifications Display: Large, four digit, continuous ranging LCD readout for display of count rate, dose rate, overflow, low battery, and detector failure. LED: Flashing count rate indication with Audio Piezo electric element synchronized with count LED. Units: Counts per second (CPS) or counts per minute (CPM) and µsv/hr or mr/hr. Controls: Three key keypad with positive feedback for ON/OFF Key combinations for selecting count rate or dose rate unit displays. Power: Standard 9V alkaline battery - provides approximately 50 hours continuous use with speaker off. Automatic battery check under full load. Detector: 1.75" Pancake GM tube - LND73118 or equivalent Window : Mica, 1.5-2.0 mg/cm2 protected by stainless steel mesh. Count Range: 0-42,000 cps Sensitivity: Approximately 5.8 cps/µsv/hr (58 cps/mr/hr) - 137Cs Measuring Range: 0.05µSv/hr to 7mSv/hr (5µR/hr to 700mR/hr) Display Resolution: 0.01µSv/hr (0.001mR/hr) Background: 0-1 cps Temperature Range: Operation: - 10oC to +50oC (15oF to 122oF) Storage: - 20oC to +60oC (- 5oF to 140oF) Humidity Range: 40% to 95% RH (non condensing) Case: High impact ABS Dimensions: 11.4cm *7.2cm *6.7cm (4.5" x 2.8" x 2.6") (including Detector) Weight: 560 gram (1.23 lbs) (including battery)

RAM GAM-1 Gamma Survey Meter with state of the art microprocessor Compact, portable, lightweight designed for single- handed operation Offers optimal performance and is ideal for maintaining the highest safety standards in various applications

RAM GAM-1 Features Large, four digit, continuous ranging, LCD display Simple, three key operation Readout of dose rate and accumulated dose Units of either mr or µsv Programmable alarm thresholds Audible and visual (LED) count rate indication Smart software provides fast, yet stable response Dead time correction Alarms for detector overflow, low battery and detector failure Automatic self diagnostic routines Durable case with splash resistant keypad

RAM GAM-1 Specifications Display: LED: Audio: Units: Controls: Power Source: Detector: Measuring Range: Large, four digit, continuous ranging, LCD readout for display of accumulated dose, dose rate, alarm threshold value, overflow, low battery, and detector failure Flashing count rate indication Piezo electric element synchronised with count LED mr and mr/hr or µsv and µsv/hr Three key keypad with positive feedback for ON/OFF, RESET and SPEAKER. Key combinations for selecting accumulated dose and threshold displays Standard 9V alkaline battery - provides approximately 50 hours continuous use with speaker off. Automatic battery check under full load. Energy compensated GM tube - ZP1201 or equivalent 0.05mR/hr to 999mR/hr (0.5µSv/hr to 9999µSv/hr) Display Range: Sensitivity: Accuracy: Energy Range: Energy Dependence: Angular Dependence: 0.05mR/hr to 999mR/hr (0.5µSv/hr to 9999µSv/hr) 17 cps/mr/hr (137Cs) ±15% of reading within measuring range 50keV to 2.0 MeV ±20% related to 137Cs Less than ±20% for ±45o of preferred direction Temperature Range: Operation: -10oC to +50oC (15oF to 122oF) Storage: -20oC to +60oC (-5oF to 140oF) Humidity Range: 40% to 95% RH (non condensing) Case: High impact ABS Dimensions: 13cm x 7.2cm x 3.4cm (5.12" x 2.83" x 1.34") Weight: 0.280 Kg (0.62 lbs)

DRM Data Radiation Monitor The DRM- 2 is a GM tube- based wide range Area Monitor designed specifically to be used as a fixed monitor in varying dose rate fields using two very sensitive, auto switching GM tubes. The DRM s detector features a linear response from 0.1µSv/h to 10Sv/h (10uR/h to 1000R/h). Wall- mounted instrument that can be connected to AC power with NiMH backup batteries. The radiation data is sent via 900 MHz FHSS or 2.4 GHz FHSS radios to a transceiver or via hardwire (RS- 232 or RS- 485) to a Remote Monitoring System. The DRM- 2 can also be connected directly to a computer input.

DRM Applications Perimeter or boundary surveillance The DRM is a portable or fixed position device used for perimeter and/or boundary monitoring used to quickly identify changing radiological conditions. Collection of radiological survey data for real- time mapping and surveillance software The DRM provides live radiological data for display, archiving and trending in real- time mapping software programs (e.g. TeleMap).

DRM Features Readout of dose rate and accumulated dose Ruggedized construction, metal casing User- selectable internal alarm threshold Built- in RS- 232/RS- 485 communication connection for use with Area Monitor or WRM transmitter. Output plug for Local Alarm Unit. Calibration software (optional) Dead time correction Alarms for detector overflow, low battery and detector failure Automatic self diagnostic routines RADNET and CE compatible

DRM Specifications Measuring Range: Sensitivity: Accuracy: Units: Power Source: Temperature Range : 0.1. µsv/hr to 10Sv/hr (10µR/hr -1000R/hr) 0.3cps/mR/hr (137 Cs) ±10 % of reading within measuring range µsv and µsv/hr or mr and mr/hr External AC Power backed up by two NiMH batteries Operation: -10oC to +50oC (15oF to 122oF) Storage: -20oC to +60oC (-5oF to 140oF) Humidity Range : Case: 40% to 95% RH (non condensing) Blue anodized aluminum Dimensions: 93mm W x 148mm L x 56mm H (3.7 " x 5.8 " x 2.2 ") Weight: Radio Frequencies: 680g (1.5 lbs) 900 MHz FHSS or 2.4 GHz FHSS