Operating Manual MS220Vi and MSR220Vi

Similar documents
Operating Manual MS220VA and MSR220VA

Operating Manual MS220KA and MSR220KA

Operating Manual MS220DA

Operating Manual TR600

Operating Manual MSF220V(VU)

Manual Isolating Barrier D461R1 (Revision 01)

Manual Isolating Barrier D461 (Revision 05)

Overload Relay EMT6 Overload monitoring system for machines operating in the EEx e area

PROTECT SRB 200EXi-1A

Physikalisch-Technische Bundesanstalt

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Monitoring Relays. 3RN1 Thermistor Motor Protection. For PTC sensors. 7/120 Siemens LV 1 T 2008

M LLET. Silo pressure detector. Füllstandtechnik. Operating instructions. 1. Description. 1.5 Dimensions. 1.1 Intended use. 1.

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

OPERATING MANUAL RAY-NC 1000 SERIES

Hazardous Location Heaters. Thermostat INSTRUCTION MANUAL

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

Inductive slot sensor

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

DICTATOR Hold-Open Systems for Hazardous Areas

Technical Data. Dimensions

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

PEPPERL+FUCHS GmbH

Operating Instructions VLT PTC Thermistor Card MCB 112

Temperature-Relay TR210

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

MANUAL Overflow sensor NVF-104/34-PF

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

DTA04. Motor thermistor relay. Benefits. Description

Technical Data. Dimensions

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

DTA. Motor thermistor relay. Benefits. Description

Technical Data. Dimensions

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

QFM21... Duct sensors. Symaro. for relative humidity and temperature

UV Flame Supervision System

Gas cylinder scale Model GCS-1

SET Installation and Operating Instructions. Level switch for one sensor

Manual Power relay SR853

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

Installation and Operating Instruction

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

SET-2000 Oil/Sludge 12 VDC

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

4) Intrinsic Safety Certification

Operating Guide Safe Torque Off

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

OPERATING INSTRUCTIONS. for the heat press. Secabo TPD7

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

The CE Marking Access to the European Market

MANUAL. for heat presses. Secabo TC5 and TC7

OilSET-1000 (12 VDC)

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

MANUAL Oil Level Sensor

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

DB5 Intrinsically Safe Sounder Type DB-5

Universal-Relay TR 800 Web

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

OPERATING INSTRUCTIONS. for the heat press. Secabo TCC

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

SEPARIX. Technical Documentation. SEPARIX-C/-T and SEPARIX-Control CT. Edition: Version: 5 Art. no.:

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

OPERATING INSTRUCTIONS. for the heat press. Secabo TC D7

ISIS SAFETY SYSTEM Installation guide

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

MANUAL. for heat press. Secabo TC2

Universal Tank Alarm Type Installation, Operation & Maintenance

C Note! LGI16... Burner Controls. Building Technologies

SET-2000 Hi Level/Oil

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Operating Instructions Edition 02/2007

Drive systems for the chemical, oil and gas industry. Electric drives and systems

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

INSTRUCTION MANUAL (ATEX)

Project planning (original) EN. Functional safety. Inverter i550-cabinet kw

FUNCTIONAL SAFETY OF ELECTRICAL INSTALLATIONS IN INDUSTRIAL PLANTS BY OTTO WALCH

INSTRUCTION MANUAL (ATEX / IECEx)

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

Temperature Sensor TRG Original Installation Instructions English

Remote alarm indicator and test combination MK2430

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

Sensor module. Operating instructions. Sensor module, Type 17-51P2-... Document No P2-7D0001 Version: 17 May 2011/Rev. 0

Electronic Temperature Controller 70304,

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Transcription:

ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße 13, D 74523 Schwäbisch Hall + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA Mains Monitoring Digital Panelmeters MINIPAN Switching Relays and Controls Measuring Transducers Grid- and Plant Protection Operating Manual MS220Vi and MSR220Vi updated: 2016-04-20 Su - PTC Thermistor Relay TMP tripping device II (1) G [Ex ia] IIC II (1) D [Ex iad] EC-type-examination certificate PTB 07 ATEX 2055 - marking see type plate MS220Vi and MSR220Vi 11910-0701-00 Page 1 / 12 www.ziehl.de

Table of contents 1 Application... 2 2 Short Description... 2 3 Simplified diagram... 3 4 Connection plan... 3 5 Functional diagram... 4 6 Detailed description... 4 7 Important notes!... 5 8 Installation... 6 9 Commissioning... 6 10 Special remarks for explosive gas atmospheres areas Zone 0, Zone 1 and Zone 2.... 6 11 Special remarks for use in the presence of combustible dust Zone 20, Zone 21 and Zone 22.... 6 12 Special remarks for category 2 of EN ISO 13849-1... 7 12.1 Wiring... 7 12.2 Safe Separation... 7 12.3 Manual resetting... 7 13 Maintenance and repair... 8 13.1 Warranty... 8 13.2 Safety Integrity Level... 8 14 Trouble shooting... 8 15 Technical Data... 9 16 Dimensions - Design V4... 11 17 EU Declaration of Conformity... 12 1 Application TMP tripping device MS and MSR work as thermal overload protection according EN 60947-8 (VDE 0660 part 0302). PTC-Thermistor sensors with characteristic according DIN 44081 und DIN 44082 can be connected. The TMP tripping device can be used to protect electrical machines against inadmissible heating due to overload. 2 Short Description TMP tripping devices MS 220 Vi und MSR 220 Vi are build as associated electrical equipment with type of protection intrinsic safety "i". The protection devices monitor electrical apparatus for explosive gas atmospheres (Zone 0, 1 und 2) and electrical apparatus for use in the presence of combustible dust (Zone 20, 21 and 22) against inadmissible heating, also the temperature of coolant, air stream and gases. All functions in the TMP tripping device serve to protect non-explosive-protected equipment and explosive-protected equipment in regular operation and in case of failure. Installation only in safe area! MS 220 Vi without electronic reclosing lock MSR 220 Vi with electronic reclosing lock (disconnectible) MS220Vi and MSR220Vi 11910-0701-00 Page 2 / 12 www.ziehl.de

3 Simplified diagram Hazardous area Safe area Reset T1 Y1 Y2 12 14 22 24 1...6 PTC T2 PA + ~ Us _ ~ 11 21 4 Connection plan Ex = area of potentially explosive atmosphere PTC = Thermistor sensor Us = supply voltage S1 = external Reset S2 = pushbutton OFF S3 = pushbutton ON H1 = trip alarm F1-F4 = fuses K1 = contactor 1) only MSR 2) twisted lines MS220Vi and MSR220Vi 11910-0701-00 Page 3 / 12 www.ziehl.de

5 Functional diagram MS 220 Vi (auto reset) MSR 220 Vi 6 Detailed description All MS 220 and MSR 220 tripping devices work according to the closed-circuit principle. A current monitors continuously the resistance of the sensors. In cold state, the resistance is <250 Ω per sensor (sensor circuit < 1.5 kω). The relay has picked up and contacts 11/14 and 21/24 are closed. The resistance of the sensor rises rapidly at nominal response temperature NRT. The relay releases at a resistance of 3 4 kω and contacts 11/12 and 21/22 close. The devices also switch off in the case of sensor or line short-circuit (< approx. 20Ω) or sensor or line interruption. MS types switch on automatically when the temperature has decreased approx. 5 C. MSR types with electronic reclosing lock store shutdown and require a RESET (push built-in button or external with terminals Y1/Y2 closed or by return of supply voltage). Storage is not non-volatile. With terminals Y1/Y2 bridged, the electronic reclosing lock is deactivated. Then the devices work like type MS. Depending on the number of sensors the following tripping and release temperatures will be achieved with respect of TNF (nominal response temperature of the sensors): Trip temperature Release temperature 1 Sensor TNF + 15 K TNF + 5 K 3 sensors in series TNF + 5 K TNF 5 K 6 sensors in series TNF TNF 20 K MS220Vi and MSR220Vi 11910-0701-00 Page 4 / 12 www.ziehl.de

7 Important notes! Warning! Can cause electrical shock and burns. Disconnect power before working on equipment. Read and understand these instructions before installing, operating or maintaining the equipment. To use the equipment flawlessly and safely, transport and store properly, install and start professionally and operate as directed. Only let persons work with the equipment who are familiar with installation, start and use and who have appropriate qualification corresponding to their function. They must observe the contents of the instructions manual, the information written on the equipment and the relevant security instructions for the setting up and the use of electrical units. The equipment is built according to EN 60947 and checked and leaves the plant according to security in perfect condition. To keep this condition, observe the security instructions with the headline Attention" written in the instructions manual. Ignoring of the security instructions may lead to death, physical injury or damage of the equipment itself and of other apparatus and equipment. If, in any case the information in the instructions manual is not sufficient, please contact our company or the responsible representative. Instead of the industrial norms and regulations written in this instructions manual valid for Europe, you must observe out of their geographical scope the valid and relevant regulations of the corresponding country. Attention! Devices with electronic reclosing lock (Reset) do not fulfill the requirements for safety circuits in accordance with EN 60204. The equipment must not be used alone for functions, when an automatic start must be avoided. Attention! The relay contacts must be fused externally to prevent welding of the contacts. Recommended fuses see technical data. MS220Vi and MSR220Vi 11910-0701-00 Page 5 / 12 www.ziehl.de

8 Installation The device must be installed within rooms of international protection class IP 5x or better. The device can be mounted on 35 mm standard rail according EN 60715 or assembled with screws M4. Observe the maximum admissible temperature when installing in a switchgear cabinet. Make sure sufficient space to other equipment or heat sources. If the cooling becomes more difficult e.g. through close proximity of apparatus with elevated surface temperature or hindrance of the cooling air, the tolerable environmental temperature is diminishing. 9 Commissioning The applicant must observe safety rules and standards. Notice safety remarks! The correct function of the tripping device must be checked by resistance simulation at terminals T1 and T2. This check is also performed after changes to the installation. Attention! Before switching on make sure that the operational voltage Us of the Type plate and the mains voltage are the same! Safety Instructions and references for putting into operation please read carefully! 10 Special remarks for explosive gas atmospheres areas Zone 0, Zone 1 and Zone 2. The increased danger within hazardous areas requires the careful attention of the safety instructions and references for putting into operation. Observe the national safety rules and regulations for prevention of accidents as well as the European Standards EN 60079-14. Installation, electrical connection and commissioning to be carried out by trained service personnel only. Inappropriate behavior can cause heavy personal damage and damages to property. The response of the thermal motor protection must directly switch off the motor, also when used together with converters. This must be realized in the logic section or configuration in the converter. The relay may be installed only outside potentially explosive atmospheres. Within potentially explosive atmospheres the equipment is to be provided with a pressurized enclosure according EN 60079-2. To limit the maximum surface temperature the protective device has to be installed in accordance with the requirements and this document. The protection device must disconnect the power supply from the apparatus, either directly or indirectly. Reset should admissible by hand only. 11 Special remarks for use in the presence of combustible dust Zone 20, Zone 21 and Zone 22. The increased danger within hazardous areas of combustible dust requires the careful attention of the safety instructions and references for putting into operation. Observe the national safety rules and regulations for prevention of accidents as well as the European Standards EN 60079-14. Installation, electrical connection and commissioning to be carried out by qualified service personnel only. Inappropriate behavior can cause heavy personal damage and damages to property. The relay may be installed only outside potentially explosive atmospheres. Within potentially explosive atmospheres the equipment is to be provided with a dust proofed enclosure according to EN 60529. MS220Vi and MSR220Vi 11910-0701-00 Page 6 / 12 www.ziehl.de

12 Special remarks for category 2 of EN ISO 13849-1 12.1 Wiring The lines of the sensor circuit are to be routed as separate control lines. The use of lines of the supply cable or other mainstream lines is not permissible. If extreme inductive or capacitive stray effects are to be expected by parallel cables of the power installation, shielded control lines should be used. For devices type MSR the terminals Y1, Y2 may be attached parallel to a common resetting mechanism. Sensor lines may not be connected together. The line resistance within the sensor circuit may not exceed a value of 20 Ω. Maximum of permissible length for sensor circuit lines: Wire cross section Wire length 2,5 mm 2 2 x 500 m 1,5 mm 2 2 x 400 m 1,0 mm 2 2 x 250 m 0,75 mm 2 2 x 150 m 0,5 mm 2 2 x 100 m 0,34 mm 2 2 x 100 m 0,22 mm 2 2 x 50 m 0,14 mm 2 2 x 40 m With commissioning and after modification of the plant the sensor resistance must be checked with a suitable measuring instrument. With a resistance < 50 Ω the sensor circuit is to be examined for short-circuit. Attention! Check PTCs only with measuring voltages of < 2.5 V. 12.2 Safe Separation Mains supply circuits (A1, A2, 11,12,14 and 21, 22, 24) have a safe separation in devices with transformer to low-voltage electric circuits (Y1, Y2) as well as to the intrinsic safe circuit T1, T2. Tripping relays with supply voltage DC/AC 24 V are permissible only at power supplies according EN 61558-2-6 when protected wiring is used. 12.3 Manual resetting After introducing a stop instruction by the protection device this must be maintained, until the manual resetting mechanism is operated and safe conditions for a renewed start are given. The manual resetting may be only possible, if all safety functions and protection devices are effective. Trip device type MSR has an electronic reclosing lock. The stop instruction remains, until by pressing the push-button Reset reset is made. A start-up is only possible, if no case of failure occurs and the motor is cooled down to a sufficient value of temperature. Trip devices type MSR 220 switch on automatically with return of supply voltage. The user must guarantee by external interlock so the supervised motor/machine does not start again independently. MS220Vi and MSR220Vi 11910-0701-00 Page 7 / 12 www.ziehl.de

13 Maintenance and repair The devices are maintenance-free. Only the manufacturer may accomplish repairs. EN 60079-17 and/or EN 61241-17 are to be observed. Attention! If the internal fuse has triggered, with high probability a failure occurred inside the equipment. In this case, the device has to be reviewed and / or repaired in the factory! The device must not be repaired from the user and replaced by a similar device. Testing the safety function The safety function of the safety related parts has to be tested with commissioning and within regular intervals. It is recommended to test once annually or within the maintenance cycle of the plant. For recurring examinations of electrical systems in hazardous areas the inspection period must be kept within 3 years. Depending on the zone risk tests should be conducted more frequently. One fault is recognized by the safety test. One fault between safety tests can cause the loss of protection. The safety function has to be tested by interrupt of the sensor line at terminals T1 or T2. The short circuit monitoring function has to be tested by bridging the sensor line at terminals T1 and T2. Trip relay MSR the function of the electronic interlock has to be tested additionally. If an error is detected no restart must be induced until the error is cleared. 13.1 Warranty The guarantee presupposes the observance of these operating instructions (safety and start-up instructions). 13.2 Safety Integrity Level The safety function of the safety equipment according IEC 61508 achieves SIL 1 within a proof test interval of 3 years. 14 Trouble shooting Relay does not pick up. Please check The supply voltage Us at terminals A1-A2. With ready for use equipment the green LED lights. The PTCs at terminals T1-T2. In the case of disturbance the red LED lights, with type MSR the RESET button lights red. The resistance of a PTC circuit must be at 0 Ω < R < 1500 Ω. The terminal voltage T1-T2 is to be < 2.5 V with connected PTC. Push the reset button of relay type MSR. The relay can pick up at resistance R < 1.65 kω Alternatively reset can be done with closing an external contact at terminals Y1-Y2 or with power recovery. Relay does not release. Please check With no PTC sensor connected the PTC Trip Relay must release. The voltage at terminals T1-T2 must be approx. 8 V. Alternatively bridge the terminals T1, T2 (short circuit). In case of any other malfunctions, replace the device. Please add a description of the occurred malfunction when sending back for repair. MS220Vi and MSR220Vi 11910-0701-00 Page 8 / 12 www.ziehl.de

15 Technical Data Intrinsic safety circuit Voltage Uo Current Io Power Po max. permissible values max. ratio Lo / Ro Rated Voltage Um 8.61 V 61.7 ma 0,133 W IIC C O ( F) 1,0 1,3 1,5 L O (mh) 2,0 1,0 0,5 198 µh/ω 250 V Power supply see type plate of the device Rated supply voltage Us AC 110-120 V, AC 220-240 V, AC / DC 24 V Tolerance voltage Us AC 0.9Us... 1.1Us DC 21... 30 V Rated frequency 50 / 60 Hz Tolerance frequency 45 Hz - 62 Hz Rated power consumption 2 VA 1.2 W PTC resistor connection PTC - sensor DIN 44081/DIN 44082 Number set with 1 6 PTCs in series Cut-out-point 3.3 kω 3.65 kω 3.85 kω Reclosing point 1.7 kω 1.8 kω 1.95 kω Response tolerance ±6 C Collective resistance cold sensors 1.65 kω Terminal voltage (sensors) 2.5 V at R 3.65 kω 9 V at R = Terminal current (sensors) 1 ma at R 20 Ω Short circuit 20 Ω R 40 Ω Power output 2 mw Relay Output EN 60947-5 Contacts 2 Wechsler Switching voltage max. AC 250 V Switching current max. 5 A Switching power AC cos =1 max. 2000 VA (ohm resistive load) 120 W at DC 24 V Rated operational current (Ie) 3 A AC15 250 V; 2 A DC13 24 V Recommended fuse 3,15 A slow blow (gl) Mechanical contact life 3 x 10 7 cycles Electrical contact life 1 x 10 5 Cycles at 240 V / 5 A Factor of reduction cos = 0.6 0.5 of max. switching capacity Testing conditions EN 60 947/EN 50020 Rated insulation voltage Ui 250 V Rated impulse voltage 4000 V Contamination level 2 Transformer EN 61558-2-6 (VDE 0551) Rated operational temperature -20 C... +60 C Storage/ambient temperature -40 C +70 C EMC - Immunity EN 61000-6-2 EMC - Emission EN 61000-6-3 Vibration resistance EN 60068-2-6 2 25 Hz ±1.6 mm 25... 150 Hz 5g MS220Vi and MSR220Vi 11910-0701-00 Page 9 / 12 www.ziehl.de

Housing Design V4 (distribution box) Depth 55 mm Wide 4 TE Dimensions (H x W x D) mm 90 x 70 x 58 Line connection solid wire 1 x 0.5... 1.5 mm 2 Stranded wire with insulated ferrules 1 x 0.25 mm 2... 1.0 mm 2 Torque 0.5 Nm (3.6 lb.in) Protection class housing EN 60529 IP 30 Protection class terminals EN 60529 IP 20 Fitting position any Attachment mounting EN 60715 35 mm standard rail Optional: Screw mounting M4 Only with additional bar (not included) Weight approx. 180 g Subject to technical modifications MS220Vi and MSR220Vi 11910-0701-00 Page 10 / 12 www.ziehl.de

3 61,8 45 (90) 116 98 16 Dimensions - Design V4 Dimensions in mm 58 48 16,5 70 Option 5 4 1 2 3 6 7 1 Oberteil / cover 2 Unterteil / base 3 Riegel / bar for snap mounting 4 Plombenlasche / latch for sealing 5 Frontplatteneinsatz / front panel 6 Kennzeichen für unten / position downward 7 Riegel bei Wandbefestigung mit Schrauben. Riegelbohrung Ø 4,2 mm / for fixing to wall with screws, Ø 4.2 mm. You can find these and other instruction manuals on the Internet at www.ziehl.de MS220Vi and MSR220Vi 11910-0701-00 Page 11 / 12 www.ziehl.de

17 EU Declaration of Conformity EU-Declaration of Conformity Erklärung/Declaration No. 11915-1300-01 Hersteller: Manufacturer: Anschrift: Address: Produktbezeichnung: Product specification: Typ: Type: Ziehl industrie-elektronik GmbH & Co KG Daimlerstr. 13 74523 Schwäbisch Hall Germany Motorschutzgerät Thermistor motor protection MS220Vi T222181 T222185 MSR220Vi T222191 T222195 Wir erklären in alleiniger Verantwortung, dass oben bezeichnetes Produkt den grundlegenden Anforderungen entspricht die in den folgenden Europäischen Richtlinien festgelegt sind: We declare under our sole responsibility that above designated product meets the basic requirements and complies with the following directives of the European Union: 2014/35/EU 2014/30/EU 2014/34/EU 2011/65/EU Niederspannungsrichtlinie Low Voltage Directive EMV Richtlinie EMC Directive ATEX Richtlinie ATEX Directive RoHS Richtlinie RoHS Directive Angewandte harmonisierte Normen und technischen Spezifikationen: Applied harmonised standards and technical specifications: Benannte Stelle und Nummer der EG- Baumusterprüfbescheinigung: Notified Body and number of the EC-typeexamination certificate: Schwäbisch Hall, 20.04.2016 Ort, Datum der Ausstellung Place, date of issue EN 60947-8:2003 + A1:2006 + A2:2012 EN 61000-6-2:2005 + AC:2005 EN 61000-6-4:2007 + A1:2011 EN 60079-11:2012 EN 50581:2012 PTB Physikalisch Technische Bundesanstalt 0102 PTB 07 ATEX 2055 CE-Kennzeichnung: 2007 CE marking in: ppa. Herbert Wahl Verkaufsleitung i.v. Bernhard Scheu Qualitätsmanagement MS220Vi and MSR220Vi 11910-0701-00 Page 12 / 12 www.ziehl.de