Cylindrix III Mini. 3.5" Round Surface Canopy

Similar documents
Performance Chart Electrical Data

Classix 6" 6" Round Downlight

Hornet HP. Semi-Recessed 4-Light Square Multiple

Hornet HP. Round Glass Downlight

Evoke Square Downlight

Hornet HP. Recessed 4-Light Square Multiple

Hornet HP. Square Glass Downlight

Evoke 2.9" HP. 2.9" Square Downlight

Evoke Square Downlight

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

Evoke Square Downlight

Evoke 2.9" HP. 2.9" Square Downlight

Performance Chart Electrical Data

Evoke Square Adjustable C3M

Essenza. Round Downlights

Velato. Recessed Slot Adjustable Multiples

Evoke Square Adjustable HP

Classix 6" 6" Round Adjustable C3M

Classix 6" 6" Round Lens Wall Wash

Murro HP. 3.5" Round Surface Canopy Wall Wash

Evoke Round Adjustable C3

Essenza. Square Downlights

Evoke Square Adjustable HP

Classix 6" 6" Round Adjustable C3

Evoke Round Downlight

Classix 6" 6" Round Lens Downlight

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Classix 6" 6" Round Adjustable C3

Classix 6" 6" Round Lens Wall Wash

Classix 6" 6" Round Lens Wall Wash

Performance Chart Electrical Data

Performance Chart Electrical Data

Performance Chart Electrical Data

HORNET-HP-R- A14-3 3LT LED

approved to UL standard as tested by CSA Damp location Wet location option (adds clear lens and trim gasket) IC/AT rated (27w only) 4 11 / / 8

Performance Chart Electrical Data

Grüv Flare Regressed. Recessed Linear LED

Etch 2' x 2' Recessed LED

Grüv Flare Regressed. Recessed Linear LED

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Linea 1.5. Linear Direct Wall Wash LED

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Fino. Asymmetric Wall Mount Indirect LED

IHOL-8DS / ISD802 8 Gravity LED Square Downlight with Regressed Lens - Wet Location

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

3.75 Gyro Shift Multiples Single Head

Ordering Example: Specify trim code and housing code to order: Example : 1020W - B LRTD M2-27KS NCSM - 277V - DIML2 - CB27

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) F Frosted S Solite (provided standard) RETROFIT

PROJECT INFORMATION DELIVERED PERFORMANCE. BeveLED REGRESS DOWNLIGHT DELIVERED PERFORMANCE. BeveLED 2.1 WGD DEEP REGRESS DOWNLIGHT

USAI. BeveLED2.1. BeveLED. COLOR SELECT Covered By US Patents 8,581,520 and 8,456,109 DOWNLIGHT 1 REGRESS DOWNLIGHT DEEP REGRESS DOWNLIGHT.

IHOL-4DR / IRD400 4 Gravity LED Downlight

Linea 2.5. Linear Indirect LED

Fixture Summary (see following pages for more information) Performance Chart Wattage Per Foot. Standard Patterns " "

IHOL-S4DR / IRDS400 4 Gravity LED Shallow Downlight

IHOL-6DS / ISD600 6 Gravity LED Square Downlight

BEVEL STYLE LENS B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

IHOL-6DR / IRD600 6 Gravity LED Downlight

Catalog # Project. Comments. Prepared by

Linea 2.5. Linear Direct/Indirect LED

DIMMING: (optional) Multiple dimming drivers available. See compatibility chart attached.

PROJECT INFORMATION DELIVERED PERFORMANCE. Performance based on: 3000K, 50 beam

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

DRD5S & SurfaceFrame Alt/EM 18" Linear Surface Mount LED Area Light

FLANGE FINISH. New Construction, Narrow Width IC Insulation-Contact Rated / Airtight 2 40KS 4000K, 80+ CRI CP Chicago Plenum beam beam

PROJECT INFORMATION. DATE Covered By US Patent 8,456,109 and 8,581,520

HALO. 2700K nominal. 3000K nominal. RA4 LED Very Wide Flood (VWFL)

DRD5S & SurfaceFrame Alt/EM Surface Mount LED Downlight

RA406930NFLWH 4" Led Adj Gimbal 30K 120V Narrow FLD

Ordering Example: Specify trim code and housing code to order: Example : 1251W - B LRTW M2-27KS - NCSM - 277V - DIML2 - CB27

PROJECT DATE FLANGE FINISH

Type: Project : Luminaire characteristics: Source: Lumen maintenance: Optics: Material: Mounting: Electrical: Finish: Weight:

PROJECT INFORMATION B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

FLANGE FINISH VOLTAGE. NC New Construction CP Chicago Plenum 2 IC Insulation-Contact Rated / Airtight 2 120V 277V

DATE TYPE 40 DELIVERED PERFORMANCE

USAI ADJUSTABLE. Lighting

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles)

80 Watts FLANGE FINISH

Linea 3.5. Linear Direct/Indirect LED

lumenalpha downlight Specification Sheet

Evolution EXWW RECESSED LINEAR WALL WASH LUMINAIRE

PRELIMINARY 2000K PERFORMANCE. CRI Lumen Maintenance Binning Tolerance Warranty

CRENSHAW. Board and driver LED standard systems for ceiling mounts. Crenshaw LED. Standard Ceiling Options

PROJECT INFORMATION PROJECT DATE. 9 Watts 12 Watts 16 Watts 24 Watts 33 Watts

LM Series LED Architectural Downlighting HIGH LUMEN OUTPUT RECESS / SURFACE MOUNT GREEN ENERGY EFFICIENT LIGHTING

OPTIONAL LENS 2 FLANGE FINISH

P5500 LED Architectural Downlighting

PROJECT INFORMATION FLANGE FINISH

USAI. BeveLED 2.1 International Dimming Compatibility. Lighting River Road New Windsor, NY

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. VOLTAGE. LED - high performance LED 80-80CRI 90-90CRI

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

PROJECT INFORMATION. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

PROJECT INFORMATION PROJECT DATE. 9 Watts 12 Watts 16 Watts 24 Watts 33 Watts

PROJECT INFORMATION PROJECT

diode led HYDROLUME 24V LED Strip Light 24VDC IP65

CCT LED ARCHITECTURAL MINI

VESICA LINEAR SUSPENDED VES L

Stocking Solutions. Downlights LED Panels Floods & Wall Packs

MEDLEY A. RoHS COMPLIANT INTERIOR - INTEGRAL POWER SUPPLY WHITE LIGHT & STATIC COLORS SHAPING THE EXPERIENCE OF LIGHT

Ivalo Lumaris. LED Linear Lighting. High quality, even lines of illumination and guaranteed LED compatibility with 1% Lutron dimming IVALO COLLECTION

SPECIFICATIONS Construction: Durable die-cast self flanged aluminum construction Input: Dimming: Light Source: Mounting: Finish: Standards:

Transcription:

Cylindrix III Mini Features This powerful, compact member of our Cylindrix family enhances your design aesthetics. The new Cylindrix III Mini (C3 Mini) Round Surface Canopy is tiny, passively cooled, with an invisible heat sink and full dimming capacity. It delivers brilliant colors, crispest whites, and a patent pending, field changeable optical system. Product Overview Type: Surface Accent & Display attage: 1, 18 (VNSP only), 21 umen Output: 1,8 max; 89.6 lm/ CBCP: 24,38 max Color Temp: 22K, 27K, 3K, 3K, 4K, CRISP CRI: 83 typ. (27K, 3K, 3K, 4K) + typ. (22K, 27K, 3K, 3K, 4K) Crisp & 3K Class A available : TRIAC & EV (V/277V) - % Dim utron A Series (V/277V), 3-wire/EcoSystem Hi-lume - 1% dim utron H Series (V/277V), EcoSystem, Hi-lume - 1% dim with soft on, fade to black -1V (V/277V) - 1% dim DAI (V/277V) - 1% dim Fixture Summary (see following pages for more information) Performance Chart Delivered Color atts umens P CBCP Temp 1 1,321 88.1 9,699 3K-83 18* 1,96.2 24,38 3K-83 21 1,8 89.6 13,78 3K-83 Data is based on 3K-83 V IES files available on website 1 & 21 data is based on Spot optics, 18 data is Very Narrow Spot optic only See pg 6-7 for other beam spreads Electrical Data 1 18 21 *Note: 18 is VNSP only System atts Amps System atts Amps System atts Amps V 1.13 18.1 21.18 277V 1. 18.6 21.8 Electronic constant current ED driver IT-296 2/27/18 Page 1 of 9

Housing/Frame Ordering Information 1 2 3 4 1 2 Model For New Construction C3M-RSC-NC-A17 (New Construction) C3M-RSC-CP-A17 (Chicago Plenum (CCEA) housing) C3M-RSC-IC-A17 (Insulated Ceiling/air tight housing 1 only) For Existing Ceilings C3M-RSC-REM-A17 (Remodeler) attage 1 (/277) 18 (VNSP only) 21 3 4 Voltage 277 /277 (for use with 1 only) (for non-dimming, select E/TE option) E/TE - TRIAC/EV dimming, % dim HIUME-A - utron Hi-lume A Series, 3-wire/EcoSystem, Hi-lume, 1% dim HIUME-H - utron Hi-lume H Series, EcoSystem Hi-lume, 1% dim with soft on, fade to black -1V - -1V dimming; 1% dim Options/Accessories EM - emergency battery pack with remote test switch (not available for use with REM, CP or IC options) Trim Ordering Information C3M-RSC-A17 1 2 3 4 1 2 3 Model C3M-RSC-A17 Finish T - white texture BT - black texture ST - silver texture Other finishes, consult factory Beam Spreads VNSP - very narrow spot, 8º (for 18 only) SP - spot, 14º VNF - very narrow flood, 18º NF - narrow flood, 23º F - flood, 34º F - wide flood, 44º S - linear spread, ºx1º 4 Color Temp 83 CRI + CRI 27-27K-83 229-22K-+ CRISP - Crisp 3-3K-83 279-27K-+ (not available for 3-3K-83 39-3K-+ use with VNSP) 4-4K-83 39-3K-+ 3CA - 3K Class A 49-4K-+ Options/Accessories SN - snoot, 1 length, matte black interior, exterior finish matches fixture finish HEX - hexcell louver CB - cross blade, matte black finish, requires snoot SO - solite beam softening lens The "A" refers to the sequential revision in a year and "XX" refers to the year of update. Updates coincide with improved performance while not changing the overall fixture aesthetic and are reflected in the published performance data. Please contact your Amerlux representative for explanations of changes. IT-296 2/27/18 Page 2 of 9

Specifications Application Retail and commercial accent and display lighting Construction 2 ga. galvanized steel frame 18 ga. galvanized steel splice housing and hanger brackets (not for Remodeler version) Die-cast optical housing and heat sink Optical -º tilt, 3º rotation Beam spreads: Very Narrow Spot, 8º (18 only); Spot, 14º; Very Narrow Flood, 18º; Narrow Flood, 23º; Flood, 34º; ide Flood, 44º ED Colo r Temp Options: 22K, 27K, 3K, 3K, 4K, CRISP CRI: 83 typ. (27K, 3K, 3K, 4K) + typ. (22K, 27K, 3K, 3K, 4K) Crisp* and Class A** 3K (high CRI, high gamut) available (see description below) R9 Values: 11 (83 CRI), (92 CRI) Binning: 3 MacAdam (SDCM) ife:,+ hrs, > 7% of initial lumens at, hrs *Crisp: Crisp Technology delivers the warmth of colors expected from a high CRI solution but also creates the natural crisp white color that is pleasing to the eye. It creates the most impactful lighting ever available, by revealing the richest whites and vibrant colors that pop. **Class A ED: Class A ED s have a CRI > 8 and a GAI > 8. CRI defines color Naturalness and GAI defines color Saturation. Both being high delivers rich colors and pure whites. Electrical attage: 1, 18 (VNSP only), 21 Electronic constant current ED driver, V/277V input This product complies with IEEE C62.41 for surge endurance up to 2.KV. Amerlux recommends using additional surge protection with this unit (supplied by others), surge and over voltage damage is not covered under warranty. E/TE - eading Edge, TRIAC, forward phase/trailing Edge, EV, reverse phase -1V, and utron systems also available See pages 8-9 for more dimming information Finish Powder coat paint Consult factory for custom finishes Mounting For use in T-Grid or GB ceilings; max ceiling thickness 1 Consult factory for thicker ceilings Adjustable hanger bars included (14 ½ - 2 std.) (32-48 Adjustable hanger bars available, consult factory) Certifications CSA listed to U standards IC/AT rated (optional, not for Remodeler version) For indoor use only arranty year limited warranty Emergency Battery Pack (EM) Powers fixture at.1 watts (approx. 4 m) for minutes (not for Remodeler version) IT-296 2/27/18 Page 3 of 9

(new construction): 11 1 /2 Ceiling cut out: 4 dia. Emergency Battery Pack (EM) option 12 / 16 6 4 7 1 /2 14 1 / 2 min - 2 max 7 3 /16 7 3 /4 4 3 /16 3 7 /8 11 1 /16 Optional CP or IC/AT housing 4 1 /2 /8 1" max Ø4 3 /8 Accessories (diagrams show installation order) Front door/accessory holder, hexcell, linear spread lens, solite lens Snoot accessory holder, cross blade, hexcell, linear spread lens, solite lens IT-296 2/27/18 Page 4 of 9

Remodeler: EV/Triac Ceiling Hi-lume /-1V 7 9 /16 Ø6 1 /4 2 1 /4 3 /16 11 /16 7 7 /8 2 1 /4 9 1 /4 1 11 /16 Ceiling cut out: 4 dia. 4 1 1 /16 2 1 /2 /8 4 1 /2 Ø4 3 /8 Accessories (diagrams show installation order) Front door/accessory holder, hexcell, linear spread lens, solite lens Snoot accessory holder, cross blade, hexcell, linear spread lens, solite lens IT-296 2/27/18 Page of 9

FIXTURE DATA: (Complete photometric data (.ies format) available upon request) MUTIPYING FACTORS: (Multiplying Factor is based on 3K-83 V IES file on website) attage: 1 21 Factor:.71 1. CCT: 27K-83 3K-83 3K-83 4K-83 Factor:.96 1. 1.2 1.4 CCT: 22K-+ 27K-+ 3K-+ 3K-+ CRISP 3CA Factor:.71.8.83.87.6. 21 ED, 3K (For F & F data see pg 7; For VNSP (18 only) data see pg 7) Spot (SP), 14º T #12671 umens: 1,73 Very Narrow Flood (VNF), 18º T #88322 umens: 1,8 Narrow Flood (NF), 23º T #137438 umens: 1,817 2 2 22 1 6 1 12 12 1 3 1378 986 1 112 2 6 3 211 11 1 3 1189 4 1 2337 2 7 3 13 23 1 3 893 779 1 277 2 474 3 94 APPICATION DATA: Notes and Definitions: Beam spread is to % center beam candlepower (CBCP). D=Distance to floor or wall. = on floor or wall at center beam aiming location. =Effective Visual Beam length in feet (% of maximum footcandle level). =Effective Visual Beam width in feet (% of maximum footcandle level). CB=Distance across or down to center beam location. D 3º CB 3 D CB SPOT VERY NARRO FOOD NARRO FOOD o Aiming Angle Horizontal D. 4 1.2 1.2 7. 241 1.8 1.8 1. 136 2.6 2.6 12. 87 3.2 3.2 D. 473 1.4 1.4 7. 211 2.1 2.1 1. 119 2.9 2.9 12. 76 3. 3. D. 38 1.9 1.9 7. 19 2.9 2.9 1. 3.8 3.8 12. 8 4.8 4.8 3 o Aiming Angle 3 o Aiming Angle 3º Horizontal 3º Vertical º. 348 1.6 1.4 3. 7. 1 2. 2.2 4. 1. 8 3.4 3. 6. 12. 7 4.2 3.6 7.. 3 1.9 1. 3. 7. 136 2.9 2. 4. 1. 3.8 3.3 6. 12. 4.7 3.9 7.. 27 2.4 2.1 3. 7. 11 3. 3.2 4. 1. 63 4.8 4.2. 12. 4 6.1.4 7. 3. 2 2.8 1.4. 4. 121 3. 1.8 6.. 77 4.3 2. 8. 6. 4.2 2.9 9. 3. 176 3.4 1.. 4. 18 4.1 2. 6.. 67.3 2.8 8. 6. 49 6.3 3.2 9. 3. 181 3.2 1.8 4. 4. 96 4.4 2.8 6.. 63.3 3.3 7. 6. 43 6.7 4. 8. o Aiming Angle Vertical 3. 726 1.3 1.1 2. 4. 18 1. 1.2 2.. 334 1.8 1.3 3. 6. 23 2.2 1.6 3. 3. 61 1.6 1.2 2. 4. 462 1.6 1.3 2.. 293 2. 1. 3. 6. 26 2.4 1.8 3. 3. 62 1.9 1.2 2. 4. 426 1.9 1. 2.. 249 2. 2.2 3. 6. 182 2.9 2.6 3. IT-296 2/27/18 Page 6 of 9

FIXTURE DATA: (Complete photometric data (.ies format) available upon request) MUTIPYING FACTORS: (Multiplying Factor is based on 3K-83 V IES file on website) attage: 1 21 Factor:.71 1. CCT: 27K-83 3K-83 3K-83 4K-83 Factor:.96 1. 1.2 1.4 CCT: 22K-+ 27K-+ 3K-+ 3K-+ CRISP 3CA Factor:.71.8.83.87.6. 21 ED, 3K (For SP, VNF, NF data see pg 6) Flood (F), 34º T #137439 umens: 1,84 ide Flood (F), 44º T #13744 umens: 1,679 18 ED, 3K (VNSP only) Very Narrow Spot (VNSP), 8º T #11714 umens: 24,38 12 1 1 2 1 3 22 2 3 2 1 3 4743 4 1 2871 2 829 3 178 49 1 3 3124 2988 1 233 2 876 3 287 12 1 3 2438 898 1 27 2 394 3 131 7 APPICATION DATA: Notes and Definitions: Beam spread is to % center beam candlepower (CBCP). D=Distance to floor or wall. = on floor or wall at center beam aiming location. =Effective Visual Beam length in feet (% of maximum footcandle level). =Effective Visual Beam width in feet (% of maximum footcandle level). CB=Distance across or down to center beam location. D 3º CB 3 D CB FOOD IDE FOOD o Aiming Angle Horizontal D. 1 2.9 2.9 7. 8 4.3 4.3 1. 48.7.7 12. 31 7.2 7.2 D. 12 3.3 3.3 7. 6.. 1. 32 6.7 6.7 12. 2 8. 8. 3 o Aiming Angle 3 o Aiming Angle 3º Horizontal 3º Vertical º. 13 3. 3.1 2. 7. 8.2 4.8 3. 1. 34 6.8 6.4. 12. 22 8. 8. 6.. 92 3.9 3. 2. 7. 41.6.4 3. 1. 23 7.6 7.3 4. 12. 1 9.6 9.2. 3. 113 3.4 2.7 3. 4. 64 4.6 3. 4.. 41.8 4.4. 6. 29 7..2 7. 3. 92 3.2 2.7 3. 4. 2 4.3 3.6 4.. 34.3 4.6. 6. 23 6.. 6. o Aiming Angle Vertical 3. 34 2.3 1.8 1. 4. 28 2.8 2.6 2.. 133 3. 3.1 2. 6. 93 4.1 3.8 3. 3. 24 2.3 2. 1. 4. 138 3.2 3. 2.. 93 3.9 3. 2. 6. 64 4.7 4. 2. 18 only VERY NARRO SPOT D. 967 1. 1. 7. 431 1.1 1.1 1. 243 1.3 1.3 12. 16 1.8 1.8. 624 1. 1. 3. 7. 21 1.8 1.1 4. 1. 13 2.1 1.6 6. 12. 12 2.4 2.2 7. 3. 3 1. 1.. 4. 18 2.4 1.1 7.. 129 2.7 1.2 8. 6. 3.3 1.6 1. 3. 983 1. 1. 2. 4. 729 1.1 1. 2.. 1.1 1. 3. 6. 32 1.9 1. 3. IT-296 2/27/18 Page 7 of 9

DIMMING COMPATIBIITY: Amerlux Cylindrix fixtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. Amerlux recommends testing your unique dimming configuration as the exact full configuration (Dimmer, Fixture Quantity, Voltage, etc) may affect dimming performance. --- NOTE: INFORMATION BEO IS FOR IRED DIMMERS ONY. FOR IREESS DIMMERS, CONSUT FACTORY --- TRIAC (Forward Phase) DIMMING (Standard) Utilizes Standard incandescent dimmers that are in wide use in installations across the US. Best for retrofit applications where TRIAC dimmers are installed. V or 277V* Dims down to less than % light output (most cases) Consult manufacturer for installation instructions - DO NOT SHARE NEUTRAS! Must meet dimmer Minimum oad Requirements per dimming manufacturer all Box (Incandescent Style, attage as required) utron Diva utron Vareo utron Nova-T utron Skylark utron Maestro TRIAC iring Diagram TRIAC Green ETC SR Rack w/d2 Module utron GP Panel ETC DRD Rack w/d2 Module utron Grafik Eye QS EV - Electronic ow Voltage (Reverse Phase) DIMMING (Standard) Utilizes specialized EV dimmers. Best for New Construction applications EV iring Diagram V or 277V* Dims down to less than % light output (most cases) EV Consult manufacturer for installation instructions - DO NOT SHARE NEUTRAS! Must meet dimmer Minimum oad Requirements all Box (EV Style) utron Diva utron Nova-T utron Maestro eviton Surslide utron Vareo utron Skylark eviton Vizio Green ETC SR Rack w/ev1 Module utron GP Panel with PHPM-PA Interface ETC DRD Rack w/ev1 Module utron Grafik Eye QS with PHPM-PA Interface -1V - DIMMING (--1V Option) Integrates into a variety of building management and daylighting controls -1V iring Diagram V or 277V* Dims down to 1% light output Requires interface to turn off power to driver Consult manufacturer for installation instructions - DO NOT SHARE NEUTRAS! -1V Gray Purple Green -1V (-) -1V (+) Switched Hot all Box utron Diva - DVTV with PP- H Interface eviton Renoir II -1v utron Grafik Eye with GRX-TVI Interface * is 277V dimmable with appropriate dimmer (by others). All provided wiring diagrams show V wiring colors and method. Please refer to 277V dimming installation instructions for 277V wiring diagrams. IT-296 2/27/18 Page 8 of 9

UTRON A-SERIES HI-UME / ECOSYSTEM (-HIUME-A Option) Integrates into utron EcoSystem building management 3-ire iring Diagram DIMMING COMPATIBIITY: Amerlux Cylindrix fixtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. Amerlux recommends testing your unique dimming configuration as the exact full configuration (Dimmer, Fixture Quantity, Voltage, etc) may affect dimming performance. --- NOTE: INFORMATION BEO IS FOR IRED DIMMERS ONY. FOR IREESS DIMMERS, CONSUT FACTORY --- V or 277V* Dims down to less than % light output May use 3-ire or EcoSystem Consult manufacturer for installation instructions - DO NOT SHARE NEUTRAS! Cap unused ECOSYS wires 3-ire Phase Purple Stripe Purple Orange Green E1 E2 Dimmed Hot Switched Hot all Box (3-ire Fluorescent) DIVA Maestro Nova T Vareo utron EcoSystem compatible controls ETC SR Rack w/d2f Module ETC DRD Rack w/d2f Module EcoSystem Digital iring Diagram E2 E1 ECOSYS Bus EcoSystem Purple Stripe E1 Purple E2 (Cap off Orange wire) Orange Dimmed Hot Switched Hot Green DAI DIMMING (-DAI OPTION) Digital control protocol allows individual fixture control DAI iring Diagram V - 277V* Dims down to 1% light output in most cases all Box (3-ire Fluorescent) eviton CD2 ler DAI DAI Bus Purple Purple/T Green Dynalite Fifth ight EMERGENCY DIMMING (-EM OPTION) iring Diagram Unswitched Hot Common ED oad AC ED ED ED Output Output Blue all Switch Thermal Protector T/ T/BK Blue Yellow/BK Yellow E F M E F le ER D le x D G x RI A EN B V C ER Y Violet Brown Violet Brown 2-ITS Converter Connector Test Switch * is 277V dimmable with appropriate dimmer (by others). All provided wiring diagrams show V wiring colors and method. Please refer to 277V dimming installation instructions for 277V wiring diagrams. IT-296 2/27/18 Page 9 of 9