MULTI-CHANNEL IN-OUT CABLE FREE THERMO-HYGROMETER

Similar documents
Multi-Channel IN-OUT Thermo-Hygrometer with Cable Free Sensor and RF Clock

Weather Forecast RF Wall Clock with Romote Thermometer Model: JMR818WF. User Manual

DIGITAL WEATHER FORECASTER WITH REMOTE THERMO-HYGRO SENSOR AND RADIO CONTROLLED CLOCK

Wide-Screen Weather Forecast RF Clock with Thermometer Model: JM828WF / JM828WFU. User Manual

Multi-Channel Indoor-Ooutdoor Thermohygrometer with Cable Free TM Sensor & ExactSet TM Clock

LONG-RANGE WIRELESS WEATHER STATION WITH IN-OUT THERMO-HYGROMETER AND RF CLOCK

Wake-up Vibration Alarm Model : VR101. User Manual

Digital Thermometer with Ice Alert and Radio-Controlled Clock Model: RMR682

Digital Thermometer with Ice Alert and Radio-Controlled Clock. Model: RMR382 USER MANUAL CONTENTS

Weather System Pro Model: BAR629HG / BAR629HGU User Manual

Cable Free Weather Station with Thermo-Hygrometer and Radio controlled clock

INTRODUCTION CONTENTS

EN Oregon Scientific Radio-Controlled Projection Clock (RM816P / RM816PU / RM816PUL) User Manual

Weather Station with Remote Control Model: BAR289

Digital Thermometer with Ice Alert and Clock

Desktop Dual-band Radio Controlled Clock with Melody Alarm and Backlight Model: RM926 User Manual

IN-OUT Thermometer with Cable Free Sensor and Clock

ELECTRONIC THERMOMETER. Model NTS-912 User Manual CONTENTS

WEATHER STATION WITH CABLE FREE IN-OUT THERMOMETER UV MEASUREMET AND IN-OUT HYGROMETER MOONPHASE AND RADIO CONTROLLED CLOCK (SWISS SIGNAL HBG )

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

COLOUR WEATHER STATION MODEL: AWS888N USER S MANUAL

Wireless Rain Gauge with Rainfall Memory and Digital Clock MODEL: RGR382

Weather Station Advanced Model: BAR628HG / BAR628HGU User Manual

Multi-Channel Indoor & Outdoor Thermometer with Cable Free Sensor & Radio Controlled Clock

Honeywell Temperature & Humidity Sensor with LCD

Wireless Weather Station Model: BAR826HG

RF Projection Clock Model: RM939P POLERMO Projection Clock Model: RM939PA

Radio Controlled Kids Projection Clock with Nightlight

4-Day Weather Forecaster Station Model: WMH601

Honeywell. Wireless Rain Gauge with Indoor. Temperature (TC152) USER MANUAL TABLE OF CONTENTS INTRODUCTION 3 PRODUCT OVERVIEW 4 REMOTE RAIN GAUGE 7

Weather Day & Night Model: BAR339DP / BAR339DPA / BAR339DPU / BAA339DPH

Wireless Rain Gauge with Indoor Temperature

Reset system Safety and care Warnings Additional resources Troubleshooting Specifications... 16

Honeywell. Weather Forecaster with Dual Projection (PCR426W) USER MANUAL TABLE OF CONTENTS INTRODUCTION 3 PRODUCT OVERVIEW. Error!

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

Weather Light Model: BAR210 / BAR210U / BAR210A USER MANUAL. EU-Declaration of Conformity...7 FCC Statement...7 Declaration of Conformity...

Weather Station with Remote Color Changing Light Box Model: BAR989HG / BAR989HGA USER MANUAL

Weather Station with 433MHz Thermo-Hygrometer and Radio Controlled Clock Model: 888R25 USER S MANUAL

+ECO Solar Clock Model: RMR331ES / RMR331ESU / RMR331ESA USER MANUAL CONTENTS

+ECO Solar Weather Clock Model: BAR332ES / BAR332ESA / BAR332ESU USER MANUAL CONTENTS

Wireless Humidity/ Temperature Monitor Remote Wireless Sensor

Wireless In/Out Thermometer with Atomic Clock

'bregon SCIENTIFIC. Weather Day & Night Model: BAR339DP I BAR339DPA I BAR339DPU I BAA339DPH USER MANUAL

INSTRUCTION MANUAL TRC-1490 Wireless Indoor and Outdoor Weather Station

WIRELESS WEATHER STATION WIRELESS WEATHER STATION. Please Note. We are unable to supply Additional Sensors for This Weather Station C-8105/C-8145

Honeywell Barometric Weather Forecaster (TE653ELW) USER MANUAL TABLE OF CONTENTS INTRODUCTION 3 STANDARD PACKAGE CONTENTS 3 BEFORE YOU BEGIN 4

WS WEATHER STATION

WIRELESS THERMO-HYGROMETER Instructions manual Cat. No. WS9070IT+

HTG79 Operating Instructions

WIRELESS WEATHER STATION C-8136

WS-8300U 915 MHz Wireless Weather Station Instruction Manual

WS-9023U 915 MHz Wireless Weather Station. Instruction Manual

WIRELESS MULTI-ZONE DIGITAL THERMOMETER WITH RADIO CONTROLLED CLOCK. Model No (SF Version) Instruction Manual

WIRELESS RAIN GAUGE WITH IN/OUT TEMPERATURE INSTRUCTION MANUAL

Professional Wireless Rain Guage with 4" LCD

Contents. English. French. Spanish

High Precision Digital Rain Gauge with Indoor Temperature and Humidity

433 MHz RADIO CONTROLLED PROJECTION ALARM CLOCK Instruction manual

WEATHER FORECASTER WITH IN/OUT THERMO RADIO-CONTROLLED COLOR PROJECTION CLOCK - Ref.: RPM OWNER S MANUAL -

MOONPHASE WALL CLOCK Instruction Manual

WS-9117U-IT Wireless 915 MHz Temperature Station. Instruction Manual

BBQ THERMOMETER DESCRIPTION OF PARTS. MODEL NO.: AW129/AWR129 Instruction Manual

Clock Radio. User manual AJ260. Register your product and get support at

Weather Station Wetterstation

Indoor/Outdoor Temperature Alert

WS INSTRUCTION MANUAL LED WEATHER STATION WITH RADIO CONTROLLED CLOCK AND ALARM

FEATURES AND SPECIFICATIONS

Model: T83653v2 Instruction manual DC: WIRELESS COLOR FORECAST STATION Mold Risk for Forecast Station & Indoor Remote Sensor Location

WIRELESS RAIN GAUGE WITH IN/OUT TEMPERATURE INSTRUCTION MANUAL 1. INTRODUCTION 2 2. INSTALLATION 2

Ambient Weather WS Channel Wireless Thermometer with Min/Max Display User Manual

WIRELESS COLOR FORECAST STATION

Ambient Weather RC-8365 ClearView Radio Controlled Projection Clock with Indoor Temperature User Manual

CONTENTS. La Crosse Technology, Ltd. Page 1

WIRELESS FORECAST STATION

Ambient Weather WS-16 8-Channel Wireless Thermometer with Min/Max Display User Manual

MOONPHASE WALL CLOCK Instruction Manual

La Crosse Technology WT-8002U. Digital Clock with Indoor Temperature

Water Tank Level Monitor

Wireless Weather Station with Solar Transmitter Instruction Manual

Wireless Color Forecast Station

Wireless Weather Station. Table of Contents

Operation Manual Professional Remote Weather Station

status AW1 Plus WiFi Alarm System User Manual

Owner's Manual TABLE OF CONTENTS

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Owner's Manual TABLE OF CONTENTS

Ambient Weather RC-8365 ClearView Radio Controlled Projection Clock with Indoor and Outdoor Temperature User Manual

Heart Rate Monitor MODEL: SE128 USER MANUAL

DIGITAL ATOMIC WALL CLOCK

Ambient Weather WS-091-C Three Channel Display Wireless Thermometer (Console Only) User Manual

Color Forecast Station. Table of Contents

WIRELESS FRIDGE THERMOMETER Instruction Manual

TOUCH-SCREEN WEATHER STATION MODEL WS Operation Manual

Wireless Color Weather Station

INSTRUCTION MANUAL WT 498S Radio Controlled Alarm Clock with Temperature and Calendar

Operation Manual Professional Remote Weather Station

Digital Electronic Thermostat With RF

CONTENTS. La Crosse Technology, Ltd Page 1

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

Owner s Manual TABLE OF CONTENTS

Transcription:

MULTI-CHANNEL IN-OUT CABLE FREE THERMO-HYGROMETER MODEL : EMR812HGN USER S MANUAL FEATURES: MAIN UNIT EN INTRODUCTION Congratulations on your purchase of the Multi-Channel In-Out Thermometer / Hygrometer (EMR812HGN) with a 433MHz cablefree thermo-hygro sensor. Enclosed with this package is one (1) main display unit and one (1) cable-free remote thermo-hygro sensor unit. The main unit has an extra-large multifunction 2-line LCD that shows recordings for indoor and outdoor temperatures, humidity, maximum and minimum recordings and trend indicators. The unit supports up to three 433MHz remote thermo-sensors or thermohygro sensors. A variety of additional sensors can be purchased separately. In addition to monitoring maximum and minimum temperature and humidity readings, the unit also has an alarm that can be set to activate once readings exceed a given variance. No wire installation is required between the main and remote units. As the EMR812HGN operates at 433MHz, it can be used in the U.S. and most places in Continental Europe. 1

EN A Extra large two-line Liquid Crystal Display (LCD) Multifunction display showing temperature and humidity, max./min. memory, and trend indicators for the main unit and remote sensors. B CHANNEL button - Selects among different channels - Activates remote sensor scanning mode C IN/REMOTE - Selects between the main-unit display and a selected remote unit - Activates search mode D MEM/CLEAR button - Recalls the maximum or minimum temperature and humidity readings - Clears the maximum and minimum temperature and humidity memory of remote sensor channels or the main unit display E HI/LO button - Set the upper or lower temperature alarm limits of individual channels - Confirms alarm settings F button Sets the readings for the upper or lower temperature and humidity of individual channels G AL ON/OFF button Activates or deactivates alarm H RESET Returns all settings to default values and erases all memories I J K L C/ F slide switch Selects between degree Centigrade ( C) and Fahrenheit ( F) Battery compartment Accommodates two AA-size batteries Retractable table stand For standing the main unit on a flat surface Recessed Wall-mount hole For mounting the main unit on a wall FEATURES: REMOTE THERMO-HYGRO SENSOR A Two-line LCD Displays the current temperature and humidity monitored by the remote unit B LED indicator Flashes when the remote unit transmits a reading C C/ F slide switch Selects between Centigrade ( C) and Fahrenheit ( F) D Channel slide switch Designates the remote unit Channel 1, Channel 2 or Channel 3 E RESET Returns all settings to default values F Battery compartment Accommodates two AAA-size batteries G Battery door 2

BEFORE YOU BEGIN EN To ensure proper functioning of the EMR812HGN follow this setup procedure. For best operation: 1. Assign different channels to different remote units. 2. Insert batteries for remote units before doing so for the main unit (see instructions for battery installation). 3. Place the main unit as close as possible next to the remote unit, reset the main unit after installing batteries. This will ensure easier synchronization between the transmission and reception of signals. 4. Position the remote unit and main unit within effective transmission range, which, in usual circumstances, is 20 to 30 meters. Note that the effective range is vastly affected by the building materials and where the main and remote units are positioned. Try various set-ups for best result. H I Wall-mount holder Supports the remote unit in wall-mounting Removable table stand For standing the remote unit on a flat surface 3 Though the remote units are weather proof, they should be placed away from direct sunlight, rain or snow. BATTERY AND CHANNEL INSTALLATION: REMOTE UNIT The remote thermo-hygro sensor unit uses two (2) UM-4 or AAA size alkaline batteries.

EN Follow these steps to install / replace batteries: 1. Remove the screws on the battery compartment. 2. Select the channel number on the CHANNEL slide switch. 3. Select the temperature display unit on the C/ F slide switch. BATTERY INSTALLATION: MAIN UNIT The main unit uses two (2) UM-3 or AA size alkaline batteries. Follow these steps to install / replace batteries: 1. Slide open the battery compartment door. 2. Insert the batteries strictly according to the polarities shown therein. 3. Replace the battery compartment door. 4. Insert the batteries strictly according to the polarities shown therein. 5. Replace the battery compartment door and secure its screws. Replace the batteries when the low-battery indicator of the particular channel lights up on the main unit. (Repeat the steps described in section BEFORE YOU BEGIN ) Note that once a channel is assigned to a remote unit, you can only change it by removing the batteries or resetting the unit. Replace the batteries when the low-battery indicator of the indoors temperature lights up. (Repeat the steps described in section BEFORE YOU BEGIN ) If not disposed of properly, batteries can be harmful. Protect the environment by taking exhausted batteries ot authorized disposal stations. 4

GETTING STARTED Once batteries are placed in a given remote sensor unit, it will start transmitting information at 40-second intervals. Also, for approximately a 3-minute duration, the main unit will automatically search for signals once batteries are installed. Upon successful reception, the individual channel temperature reading will be displayed on the top line and the respective humidity reading on the bottom line. The main unit will automatically update its readings at about 40-second intervals. If no signals are received, blanks --- will be displayed and the kinetic wave icon will not show. To force a signal search: Press and hold IN/REMOTE for 2-seconds to enforce a 3-minute search. This is useful in synchronizing the transmission and reception of the remote and main units. Repeat this step whenever you find discrepancies between the reading shown on the main unit and that on the respective remote unit. Kinetic-wave Icon Designated Display Indoor Display Remote Remote Remote Display Display Display Channel One Channel Two Channel Three To display temperature / humidity readings from the main unit: Press IN / REMOTE until a dot is displayed in the box under the kinetic-wave. To display temperature / humidity readings from a remote sensor: Press CHANNEL until the appropriate remote sensor channel is displayed in the box under the kinetic-wave. If no readings are received form one particular channel for more than 15 minutes, blanks --- will be displayed until further readings are successfully searched. Check the remote sensor to ensure that it is secure and that the correct channel has been selected. Optionally, press and hold IN/REMOTE for 2-seconds to enforce a search. EN HOW TO CHECK REMOTE AND INDOORS TEMPERATURES Display of readings from a remote sensor or the main unit is a onestep procedure. The remote sensor channel or the main unit display is indicated in a box under the kinetic-wave icon. HOW TO READ THE KINETIC-WAVE DISPLAY The kinetic-wave display shows the signal-receiving status of the main unit. There are three possible forms: 5

EN The unit is in searching mode. Transmission data are securely registered. No signals. Arrow indicator Temperature Trend Rising Steady Falling THE COMFORT-LEVEL ICONS Arrow indicator The comfort level is based on the recorded relative humidity. An indicator will be displayed ot show if the level is comfortable, wet or dry. Humidity Trend Rising Steady Falling Comfort-level Note: If the temperature goes above or below the temperature measuring range of the main unit or the remote unit ( stated in specification), the display will show HHH or LLL. TEMPERATURE AND HUMIDITY TREND INDICATORS The temperature-trend and humidity-trend indicators show the trends of collected readings. Arrows indicate a rising, steady or falling trend. REMOTE SENSOR SCANNING The unit can be set to automatically scan and display readings from the remote sensors. When the remote-sensor mode is active, the display will show the readings from one channel for about 4-second and then proceed to the next channel display. To activate the remote-sensor scanning mode: Press and hold CHANNEL for 2-seconds. 6

To deactivate the remote-sensor scanning mode: Press any button. HOW TO USE CHANNEL-1 TEMPERATURE/HUMIDITY ALARM EN MAXIMUM AND MINIMUM TEMPERATURE AND HUMIDITY The maximum and minimum recorded temperature and humidity readings will automatically be stored in the memory. To display the maximum and minimum display memory: 1. Select the channel to be checked. 2. Press MEM/CLEAR once to display the maximum temperature and again the minimum temperature. The respective indicators, MAX or MIN will be displayed. To clear the memory: Press and hold MEM/CLEAR for 2-seconds. If you press MEM/CLEAR now, the maximum and minimum temperatures will have the same values as the current ones until different readings are recorded. Upper and lower temperature and humidity limits for channel-1 can be set so that an alarm activates when the limits are exceeded. The high and low temperature and humidity displays are selected by sequentially pressing HI/LO. The high-low displays are as follows: Sequence Respective Display Pressing HI/LO once Enters HI temperature display Pressing HI/LO twice Enters HI humidity display Pressing HI/LO three times Enters LO temperature display Pressing HI/LO a four time Enters LO humidity display To set a high or low temperature or humidity alarm: 1. Press HI/LO, channel-1 will be displayed. 2. Press to set the temperature or humidity limit. Each press will increase increments by one degree or percentage. Press and hold the button for a rapid-scrolling sequence by increments of five. 7

EN Note: The temperature range is from -50 C (-58 F) to +70 C (158 F). If this is the first time you set the limits, the lower limit will start from -50 C (-58 F) and the upper limit +70 C (158 F). Otherwise, the reading will start from the temperature last selected. The humidity range is from 2% to 98%. If this is the first time you set the limits, the lower limit will start from 2% and the upper limit 98% Otherwise, the reading will start from the humidity last selected. To disable an alarm: 1. Enter the setting mode by pressing HI/LO. 2. Then, press AL ON/OFF. The alarm has been disabled and will not sound at the previously set limit. To disable a sounding alarm: Press any button, the alarm sound will stop. DISCONNECTED SIGNALS 3. Repeat the steps to set the upper humidity setting and the lower temperature and humidity settings. 4. When finished, press HI/LO to set another limit or wait 16-seconds and the unit will automatically return to the normal display. The respective HI, LO or both indicators will light up to signify the status of the alarm. If in another channel other than channel one is selected, when the alarm activates the display will switch to channel-1 and the display will flash. If left untouched, the alarm will activate for a 1-minute. Press any key to momentarily stop the alarm. The alarm will activate again if the limit continues exceeds the set limit. Note: If a second limit is passed while an alarm is active, the first alarm will complete its 1-minute cycle and the alarm will continue to activate for a second minute to indicate that a second limit has been surpassed. If without obvious reasons the display for a particular channel goes blank, press IN/REMOTE to enforce an immediate search. If that fails, check: 1. The remote unit of that channel is still in place. 2. The batteries of both the remote unit and main unit. Replace as necessary. Note that when the temperature falls below freezing point, the batteries of outdoor units will freeze, lowering their voltage supply and the effective range. 3. The transmission is within range and path is clear of obstacles and interference. Shorten the distance when necessary. 8

TRANSMISSION COLLISION Signals from other household devices, such as door bells, home security systems and entry controls, may interfere with those of this product and cause temporarily reception failure. This is normal and does not affect the general performance of the product. The transmission and reception of temperature readings will resume once the interference recedes. HOW TO USE THE TABLE STAND OR WALL MOUNTING The main unit has a retractable table stand, which when flipped open, can support the unit on a flat surface. Or you can flip close the stand and mount the unit on a wall using the recessed screw hole. As for the remote unit, it comes with a wall-mount holder and a removable stand. Use either to hold the unit in place. EN NOTE ON C AND F Main unit Wall-mount Table Stand The unit of temperature display is selected on the C/ F slide switch. Select C for Centigrade or F for Fahrenheit. Note that the remote temperature display on the main unit is dominated by the selection on the C/ F slide switch of the main unit. Whatever the display units of the remote sensors are, they will be automatically converted to the chosen one of the main unit. Remote unit Wall-mount Table Stand LOW BATTERY WARNING When it is time to replace batteries, the respective low-battery indicator will show up when the respective channel is selected. The battery level of the main unit will be shown on the indoor temperature when it is running low. 9

EN THE RESET BUTTON SPECIFICATIONS This button is only used when the unit is operating in an unfavorable way or malfunctioning. Use a blunt stylus to hold down the button. All settings will return to their default values. PRECAUTIONS This product is engineered to give you years of satisfactory service if you handle it carefully. Here are a few precautions: 1. Do not immerse the unit in water. 2. Do not clean the unit with abrasive or corrosive materials. They may scratch the plastic parts and corrode the electronic circuit. 3. Do not subject the unit to excessive force, shock, dust, temperature or humidity, which may result in malfunction, shorter electronic life span, damaged battery and distorted parts. 4. Do not tamper with the unit s internal components. Doing so will invalidate the warranty on the unit and may cause unnecessary damage. The unit contains no user-serviceable parts. 5. Only use fresh batteries as specified in the user s manual. Do not mix new and old batteries as the old ones may leak. 6. Always read the user s manual thoroughly before operating the unit. Main unit Display temperature range Proposed operating range Temperature resolution : -50.0 C to 70.0 C (-58.0 F to 158.0 F) : - 5.0 C to 50.0 C ( 23.0 F to 122.0 F) : 0.1 C to ( 0.2 F) Temperature compensation : -10.0 C to 60.0 C (14.0 F to 140.0 F) Relative Humidity : 25% RH to 90% RH Operating range Remote thermo-hygro unit Display temperature range : -50.0 C to 70.0 C (-58.0 F to 158.0 F) Proposed operating range : -20.0 C to 60.0 C ( -4.0 F to 140.0 F) Temperature resolution : 0.1 C to ( 0.2 F) Temperature compensation : -10.0 C to 60.0 C (14.0 F to 140.0 F) Relative Humidity : 25% RH to 90% RH Operating range 10

General RF Transmission Frequency : 433 MHz No. of Remote unit : Maximum of 3 RF Transmission Range : Maximum 30 meters Temperature compensation : 0.1 C to ( 0.2 F) Temperature sensing cycle : around 40 seconds Power Main unit : 2 pcs UM-3 or AA 1.5V alkaline batteries Remote sensing unit : 2 pcs UM-4 or AAA 1.5V alkaline batteries CAUTION The content of this manual is subject to change without further notice. Due to printing limitation, the displays shown in this manual may differ from the actual display. The manufacturer and its suppliers held no responsibility to you or any other person for any damage expenses, lost profits, or any other claim arise by using this product. The contents of this manual may not be reproduced without the permission of the manufacturer. EN Weight Main unit : 159.5 gm Remote sensing unit : 63 gm Dimensions Main unit : 117 x 107 x 26 mm Remote sensing unit : 92 x 60 x 20 mm 11

EN ABOUT OREGON SCIENTIFIC Visit our website (www.oregonscientific.com) to learn more about Oregon Scientific products such as digital cameras; MP3 players; children's electronic learning products and games; projection clocks; health and fitness gear; weather stations; and digital and conference phones. The website also includes contact information for our customer care department in case you need to reach us, as well as frequently asked questions and customer downloads. We hope you will find all the information you need on our website, however if you'd like to contact the Oregon Scientific Customer Care department directly, please visit www2.oregonscientific.com/service/ support or call 949-608-2848 in the US. For international enquiries, please visit http://www2.oregonscientific.com/about/international/ default.asp. EC-DECLARATION OF CONFORMITY This product complies with the essential requirements of Article 3 of the R&TTE 1999 / 5 / EC Directive, if used as intended and the following standards have been applied: Safety of information technology equipment (Article 3.1.a of the R&TTE Directive) Applied Standard EN 60950: 2000 Electromagnetic compatibility (Article 3.1.b of the R&TTE Directive) Applied Standards ETSI EN 301 489-1-3 (Ver.1.4.1) :2002-08 Additional information: The product herewith complies with the requirements of the Low Voltage Directive 73 / 23 / EC, the EMC Directive 89 / 336 / EC and carries the CE marking accordingly. Carmelo Cubito Agrate Brianza (MI) / Italy January 2004 EC Mandatory of Manufacturer COUNTRIES RTTE APPROVAL COMPLIED All EC countries, Switzerland CH And Norway N 12