Once the sensors are mounted and connected to the EGI-RLC-MM, each sensor needs to be adjusted as follows:

Similar documents
Once the sensors are mounted and connected to the EGI-RLC-MM, each sensor needs to be adjusted as follows:

Capacitive Sensors with a body that is in excellent shape - The 26 Series

WHG. RoHS. Compliant. Edition February All specifications are subject to change without notice. ( )

AMERITROL, INC. INSTALLATION OPERATION MANUAL AND WIRING DIAGRAM LX SERIES LIQUID LEVEL SWITCH WITH ADDITIONAL TEMPERATURE TRANSMITTER

AMERITROL, INC. INSTALLATION OPERATION MANUAL AND WIRING DIAGRAM LX SERIES LIQUID LEVEL SWITCH. Manual Number: LX-SPDT A

AMERITROL, INC. INSTALLATION OPERATION MANUAL AND WIRING DIAGRAM LX SERIES LIQUID LEVEL SWITCH WITH ADDITIONAL TEMPERATURE SWITCH

Low-Cost, Non-Invasive, Microwave-Based Bulk Solids Flow Detector

MICROSENSE FLOW SWITCH

AMERITROL, INC. INSTALLATION OPERATION MANUAL AND WIRING DIAGRAM LX SERIES LIQUID LEVEL SWITCH. Manual Number: LX-DualSP A

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

M-Sens 2 Application overview. FlowJam application overview. Online moisture measurement for solids. For measuring capillary and surface humidity

NHR-25 Feed Hopper with Agitator

INSTALLATION INSTRUCTIONS TEC40 ELECTRONIC CONTROLLER

OilSET-1000 (12 VDC)

SET-2000 Oil/Sludge 12 VDC

Introduction to Bulk Solids. The Basics

SET-2000 Hi Level/Oil

Gate Operator. Modfications

Model Number Structure

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Eclipse 90 UV Scanner Model A Version 1

Centro-Matic Automated Lubrication Systems System Controls

Instruction Manual Model A

From simple point level controls to advanced computer-based inventory management

ABB MEASUREMENT & ANALY TICS DATA SHEET. RS85 Vibrating fork level switch

Process Protection. MFA 4P Motion Failure Alarm

POINTEK CLS 300 OINTEK CLS 300 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual December 2001

VENTURI NOZZLE SYSYTEM Specification Sheets ALL STAINLESS STEEL COMPRESSED AIR NOZZLE HUMIDIFIERS. With ON/OFF or Proportional Controls

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Ultrasonic Point Level Switches

Pneumatic Heat Press. Revision: 3 Operators Manual

SILO PROTECTION SYSTEMS

RoHS. Compliant. Edition January All specifications are subject to change without notice. (01/2018)

Features and Benefits

One Easy Strategy for Savings, Sustainability, and Productivity

Instruction Manual. Princo Model L3522. Point Level Controllers with LEVEL SENTRY. Rev 2, June 2013

FLT93 Installation, Operation and Troubleshooting Guide

Features and Benefits

Condensate Monitor CGKW. Operator s Manual 42/23-36 EN Rev. 2

MODEL 5800A CARBON MONOXIDE (CO) MONITOR AND ALARM SAMPLE-DRAWING TYPE

Operating Instructions. For. Alarm Control Module. Model SSR 500

Customers. The core of our innovation. Feeding&Conveying. Drying Dosing Temperature Control Refrigeration Granulation

FLAKER/DCM SEQUENCE OF OPERATION

E C H O T E L C O N T A C T U L T R A S O U N D

Indirect gas-fired air heater

Ultrasonic Switches. Features & Benefits

TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation 4 Detection Through Walls 4 Sensing Beam Shape 4 Installation

ProRadiant Controls, Valves and Actuators

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.


VIBRATION TRANSMITTER MODEL 140T INSTALLATION The mounting orientation can be in any position. This position should be in an area for the best vibrati

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

Snifter ATEX22 VERSION. User Manual. Distributor

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

ASTRO FF14 FRICTION FEEDER SERVICE MANUAL

CleanSpray System Operation

0-2 m/s Lo Alarm 0-6 m/s Hi Alarm Signal Stregth EASZ-12 Doppler Flow Switch Measuring Flow Worldwide

Vacuum Conveying. Industrial Equipment & Design Company....a world of experience in powder handling

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

CA5000 Liquid CO 2 Freezer Backup System

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

High Output Vacuum/Pressure Pump

SERVICE & OPERATING MANUAL ELECTRONIC LEAK DETECTOR WARNING VDC

Série Détecteur de niveau par admitance RF. SB RF-Admittance Level Switch

TEMPERATURE & PRESSURE CONTROLS

LH 3 Resina Capper Document No. LH3

Product Instructions. Basic Digital Snow Melt Control II. Applications. Features. Specifications

Table of Contents. Part Number Index SANDYS INDUSTRIAL GLASS WHEELER A

FIREYE M4RT1 FLAME SAFEGUARD CONTROLS DESCRIPTION

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

INSTALLATION INSTRUCTIONS

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

HDLV 55-Gallon Powder Drum Unloader

FC-2200 Flame Detector

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING

Dräger Flame 2500 Flame Detection

10 Considerations for Pneumatic Conveying System Design: What Most Engineering Schools Didn t Teach You

7800 SERIES EC7823/RM7823 Relay Module

Refrigerant Transfer and Compressor Damage

Ronan Model X96S Series Weighing System

Explosion Proof Push Button Momentary Switch - C1D1, C2D1 - Adjustable Timer - 10 sec-170 Minutes

Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers

Model 6495 Freezing Rain Sensor. User's Manual. All Weather Inc National Drive Sacramento, CA USA

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

NEMO BY. Industrial applications in all business fields for low to high viscosity fluids, with or without solids

PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY

DSD-3 DIFFERENTIAL SPEED DETECTOR

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

GAS MONITOR Model Model

INTRODUCTION / TABLE OF CONTENTS

RTP9 ROTARY TABLET PRESS USER MANUAL

Model HC-2. Crathco Whipped Hot Chocolate Dispenser. Table of Contents. Operation and Instruction Manual. for

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

1. Proportioning Unit DuoMix 333 PFP. Technical Specification of the Proportioning Unit Volumetric mixing ratio: 2.33 :1

Sintrol Snifter A2 EX. Manual. Version 1.2.3

T500 Elite - Hotbus Plant Wide Monitoring System for Bucket Elevators & Conveyors

Transcription:

Description: The Rechner KAS series sensors are ideal for use as level detection devices. The sensors work equally well for liquids, granulates, or powders. When a system is required to replenish a bin or tank when a low level point is reached, a control can be made using 2 sensors and the EGI-RLC-MM power supply logic controller. Function: When the system is installed as shown, the pump or conveyor used to fill the tank or bin will be controlled by the relay in the EGI-RLC-MM. When the level in the tank drops below the min sensor, the relay will energize to start the pump motor. The relay will remain energized until the tank has been filled to the max sensor. At this point, the relay will de-energize and stop the filling process. The relay will remain de-energized until the level drops below the min sensor again. The cycle then repeats to keep the tank filled. Once the sensors are mounted and connected to the EGI-RLC-MM, each sensor needs to be adjusted as follows: 1. Locate the sensitivity adjustment potentiometer on the back of the sensor. 2. Fully immerse the sensor into the product to be detected. 3. Reset the sensor s sensitivity by turning the potentiometer counter-clockwise 20 full turns, or until the sensor no longer sees the product. 4. Adjust the sensor to the product to be detected by turning the potentiometer clockwise until the sensor sees the product. 5. Add 1/4 turn for safety by turning the potentiometer a further 90 degrees clockwise. Parts Required: 2 Sensors: KAS-80-35-A-M32-Y3-NL 2 5 Meter Cables: 0.25SQX4C 1 Rechner Logic Controller: EGI-RLC-MM

Wiring Diagrams: Max Min

Description: The Rechner KAS series sensors can easily be applied to detect the accumulation of water in the bottom of oil or petroleum product tanks. Since the dielectric constant of petroleum products is considerably lower than water (the dielectric constant of water is 80 and the dielectric constant of petroleum is between 2 and 4) the KAS sensor can be adjusted to detect the water and not the petroleum. Function: The sensor should be mounted at or below the maximum acceptable water accumulation level. When the sensor detects the water, it will energize the relay providing a high water indication or alarm. The KAS sensor is capable of detecting water through glass up to 4mm (5/32 inch) thick. If a sight glass is available at or below the maximum acceptable water accumulation level, installing the sensor to detect through the sight glass eliminates the need to make a mounting hole through the tank. Adjust the sensor to ignore the oil in the tank: 1. Locate the sensitivity adjustment potentiometer on the back of the sensor. 2. Fully immerse the sensor into the oil. 3. Find the switching point of the oil by turning the potentiometer clockwise until the sensor detects the oil. 4. Adjust the sensor to ignore the oil by turning the potentiometer counter-clockwise until the sensor turns off. 5. Add 1/4 turn for safety by turning the potentiometer a further 90 degrees counter-clockwise. Parts Required: 1 Rechner Logic Controller: EGI-RLC 1 5 Meter Cable: 0.25SQX4C 1 Sensor: KAS-80-A24-A-K-Y3-NL (for through tank installation) -OR- KAS-80-A14-A-K-Y3-NL (for through site glass)

Wiring Diagrams: Through Tank Oil Water Through Site Glass Oil NOTE: 1/16 air gap between sensor and glass Water

Description: In many industrial applications vibrating rod-type level detectors are used. In some cases these devices cause problems as a result of the mechanical principle the sensor is based on. Vibrating rods, even though they are built tough, are prone to mechanical failure, or can give you false signals due to build up, or creating a cavity in compressible solids. Powder from granular material often works its way into the bearing and creates false level indication. The KAS-80-26-A-200-PTFE-1"-Y5 sensor has no moving parts and no place for material to build-up which eliminates the risk of mechanical failure. The 26 Series sensors are made with food safe PTFE. Versions for areas with a risk of dust and gas explosion are also available with AtEx and IECEx approvals. Function: Remove the old level switch and mount the new Rechner Sensor. Modification to the mounting bracket may or may not be necessary. The sensor is connected to the Rechner Logic Controller with a standard M12 connector cable. The Logic controller needs to be supplied AC power (100-240VAC). The Logic controller provides 24VDC to the sensor and controls the relay output. Once the sensor is mounted and wired the sensor needs to be adjusted. 1. Locate the sensitivity adjustment potentiometer on the back of the sensor. 2. Fully immerse the sensor into the product to be detected. 3. Reset the sensor s sensitivity by turning the potentiometer counter-clockwise 20 full turns, or until the sensor no longer sees the product. 4. Adjust the sensor to the product to be detected by turning the potentiometer clockwise until the sensor sees the product. 5. Add 1/4 turn for safety by turning the potentiometer a further 90 degrees clockwise. Parts Required: 1 Sensor: KAS-80-26-A-200-PTFE-1"-Y5 1 5 Meter Cable: 0.25SQX4C 1 Rechner Logic Controller: EGI-RLC

Wiring Diagrams: or

Description: KAS Series sensors are used as level detectors in the bulk processing industry for many operations. Dry glue pellets, which feed into hot melt glue machines, can be detected in bins, hoppers, and transfer systems. The signal from the sensors can be used to control bin levels, shut off pneumatic conveyors or operate alarm systems Function: The level of bulk pellets in the supply bin of a hot melt glue machine must be kept above a minimum level at all times to prevent the hot melt glue machine running empty. The supply bin of the machine is manually refilled with glue pellets by a worker. For detection of glue pellets, it is recommended that the sensors be immersed in the material. The nonflush mount type of sensor is installed through the wall of the bin to obtain accurate results. One KAS sensor is mounted through the wall of the supply bin at the refill level. The sensor detects a low level of glue pellets in the bin and turns on an alarm or a visual signal. This signal indicates to a worker that it is time to add more glue pellets to the bin. In this application the EGI-RLC power supply is wired as shown. The EGI-RLC acts as the power supply for the sensor as well as a signal conditioner to turn the sensor signal into a SPDT relay output. This simplifies installation and allows for a wider variety or signal devices to be used. Parts Required: 1 Rechner Logic Controller: EGI-RLC 1 Sensor: KAS-80-A24-A-K-Y3-NL (M30 diameter) -OR- KAS-80-35-A-M32-Y3-NL (M32 diameter) 1 5 Meter Cable: 0.25SQX4C

Wiring: AC power is wired to terminals 10, and 12. The sensor is wired to terminals 4, 5, and 6. The low level signal is wired to terminals 1 and 2. Adjust the sensor to detect the pellets in the tank: 1. Locate the sensitivity adjustment potentiometer on the back of the sensor. 2. Fully immerse the sensor into the bulk material. 3. Find the switching point of the bulk material by turning the potentiometer clockwise until the sensor detects the product. 4. Add 1/4 turn for safety by turning the potentiometer a further 90 degrees clockwise.

Description: Level detection of hot melt glue has many technical hurdles that need to be overcome. Most sensors will not work in the extreme heat inside of the melting tank and will not be reliable due to the viscous nature of glue. This is especially true when the machine is turned off and the glue is allowed to harden. This also creates other stresses with expansion and compression of the glue changing states. The solution is Rechner s KFS series of sensors. These durable sensors are designed to work in direct contact with the glue in extreme temperatures of up to 250 C for PTFE or PEEK housings (200 C for GFK housings) and can ignore massive amounts of glue build-up on the sensor to give you a reliable switching point the very first time you turn your machine on. Function: The sensor is mounted in the hot melt glue tank above the melting element. When the level of glue falls below the sensing point of the KFS sensor, a low level signal is sent to ask for more glue pellets. The electronics for the sensor are kept in a remote location away from the hot melt tank. The adjustment for the KFS sensor is made on this KFA amplifier. Adjustment of the amplifier takes place only after the KFS probe has been installed (mounted) and all electrical connections have been wired. Ensure that the Grounding Electrode (BE) is grounded to the tank in which the sensor is mounted. After installation, a full adjustment of the amplifier is done in this order: 1. Locate the sensitivity adjustment potentiometer on the amplifier. The actual adjustment potentiometer is recessed and may be located under a metal or plastic screw that is there to keep dust out. 2. Fully immerse the sensor up to the switching point in hot melt glue after mounting the sensor in the tank. 3. Reset the sensor s sensitivity by turning the potentiometer counter-clockwise 20 full turns, or until the sensor no longer sees the product (whichever comes first). 4. Adjust the sensor to the product to be detected by turning the potentiometer clockwise until the sensor sees the product. 5. Add 1/4 turn for safety by turning the potentiometer a further 90 degrees clockwise. Parts Required: Sensor: KFS-51-15-150-15-GFK-D16-X0E-Y55 KF0136 Amplifier: KFA-5-1-L-P-A-Z02-Y50 AF0064 Mounting Adapter: 16mm-3/4 NPT-V4A SA7004 6311 Inducon Corporate Drive, Suite 5, Sanborn, NY 14132 P: 800-544-4106 F: 905-636-0867 www.rechner.com contact@rechner.com

Wiring Diagrams: For Hot melt tanks with grid systems, the sensor is mounted above the grid and detects when the level of glue is below a specified height. Refilling is usually accomplished manually or automatically with a short filling timer. Brown = (+) Black = Normally open output White = Normally closed output Blue = (-) NOTE: The BE cable on the amplifier MUST be connected to the metal container that the sensor is mounted in for the sensor to function correctly. SA7004 16mm-3/4 NPT-V4A 16mm to ¾ compression style bushing Made of 316 stainless steel P: (888) 792-2223 (508) 842-1606 www.plastixs.com sales@plastixs.com