Genesis Whole House Chlorination System Page 2

Similar documents
Owner s Manual. Pelican Custom Premium WHWF 1354/1665

Owner s Manual. Pelican WF4/WF8 Premium Whole House Iron and Manganese Filtration System

Chanson Water USA, INC. Installation Guide for SCF-3000/SCF-6000

Owner s Manual. Pelican WF6/WF10 Iron/Manganese Filter & Salt Free Softener

Owner s Manual. Pelican NaturSoft Custom Salt Free Water Softener/Conditioner

Tier1 Water Home Filtration System

Owner s Manual. Pelican 1354 NaturSoft Custom Salt Free Water Softener/Conditioner

Installation & Service Manual

7500-S Sediment Backwash Filter Guide

ispring Whole House Water Filter Systems USER S MANUAL

The Inlet and Outlet should be as per below illustration. This will ensure that water will flow through the filter in an upflow configuration

Tier1 Water Home Filtration System

Owner s Manual. Pelican PSE1800/PSE2000 Premium Whole House Water Filter & Salt Free Water Softener Combo

Owner s Manual. Pelican NaturSoft NS3/NS6 Salt Free Water Softener/Conditioner

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

Green Water Systems OWNERS MANUAL. Includes: Installation Procedures, Warranties, Service & Operation Guidelines.

WS1 Softener Installation & Start-Up Guide

565 TLC Softener & Tannins Reduction System

5900S Softener Installation & Start-Up Guide

Installation Instructions PP-AS20 Anti-Scale System

Whole House Filter Model: WH-LD

Fleck 5600 Carbon Filter Installation & Start Up Guide

J-PRO-22 Pump Proportional Feed Chlorinator Installation & Start-Up Guide

INSTALLATION INSTRUCTIONS (please become familiar with these instructions before installing).

WHOLE HOUSE FILTER &

GROWMAX WATER Perfect Water for Plants and Gardens

Owner's Manual. WS Series. Water Softener

Installation, Operation, and Maintenance Manual. Waterlogix Metered Residential Water Softener

CWS Plus Sediment Filter Installation & Start Up Guide

Installation and Maintenance Guide

SYSTEMS for CATALYTIC FILTERS

6700 Valve Downflow. Automatic Water Softeners Operation Manual. Read all instructions carefully before operation. #51431 Rev.

Fleck 2510 SXT Catalox Installation & Start Up Guide

MASTER. Water Conditioning Corp. MP-TS-10T/20T with the 255/762 Logix Control Valve With Vortech. Installation and Operation Manual

Clean Water Made Easy

WS1 Greensand Installation & Start Up Guide

HYDROGEN SULFIDE REMOVAL SYSTEMS

Iron Air Charge MangOx 2510 SXT Installation & Start Up Guide

Installation Instructions AS-WH Whole House Water Filter

89 BIF/BAF USER MANUAL

Clean Water Made Easy

Fully Automatic Water Softeners

Professional Series. Chemical Feed System Model # US Patent No. 6,752,930 B2

Installation and Operation Manual. ACF-18 Automatic Chlorinating Feeder

Fleck 2510 Softener Installation & Start Up Guide

565 HIM Softener, Iron & Manganese Reduction System

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

5900e Neutralizer Installation & Start Up Guide

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

Fleck 7000 Sediment Filter Installation & Start-Up Guide

OZONE SYSTEM FOR IN-GROUND POOLS New and Existing

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis

6700XTR Valve Downflow

1850 Series TRIPLE TREAT Operation Manual

Table of Contents. List of Figures

1 P a g e. G4 Counter Top OPERATION MANUAL

5900S Neutralizer Operation & Maintenance Manual

PRF-RO Pentair Reverse Osmosis System Installation and Maintenance Manual SAFETY GUIDES THE BASIC REVERSE OSMOSIS SYSTEM. Tools and Materials Required

J-PRO V 230V Dual Voltage Chlorinator Installation & Start-Up Guide

Installation Manual & Owner s Guide

Installation, Operation, and Maintenance Manual

INSTALLATION & SERVICE MANUAL

Owner s Manual RD432-0 Chemical Controller

Water Softener & Single Tank Triple Treat System Installation Overview. Using 1850 Metered Valves

MP-MBA-45T-1/60T-1 / 75T-1

Econoflo Water Conditioner. Installation and Maintenance Instruction Manual

FUSION PROFESSIONAL-GRADE METERED NITRATE REMOVAL SYSTEM

7800 Neutralizer Installation & Start-Up Guide

Natural Action Technologies HOUSE UNIT INSTALLATION INSTRUCTIONS for COPPER, PEX, AND CPVC PIPES USING SHARKBITE CONNECTORS

6700 Valve Upflow. Automatic Water Softeners Operation Manual. Read all instructions carefully before operation. #57341 Rev.

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

Kinetico 2060f OD Sulfur Guard Installation Instructions

Metermatic Water Softener. Operation Manual

A2Z Ozone, Inc. PRODUCT MANUAL

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

Stenner Pump PCM Proportional Feed Chlorinator Installation & Start Up Guide

Fully Automatic Water Softeners

USER MANUAL NON-ELECTRIC MINERAL WATER PURIFIER. The Industry Leader in Alkaline Water Ionizer Technology NON-ELECTRIC MINERAL WATER PURIFIER

5900S Arsenic Filter Operation & Maintenance Manual

Fleck 2510 Sediment Filter Installation & Start-Up Guide

Clean Water Made Easy

6700XTR Upflow Valve. Water Softener Operation Manual. Read all instructions carefully before operation. #51548 Rev. 2/09

J-PRO V 230V Dual Voltage Hydrogen Peroxide Pump Installation & Start-Up Guide

Model Series ELECTRIC WATER SYSTEM PUMP. PumpAgents.com - buy pumps and parts online. Model Series. Automatic Multi-Outlet FEATURES

RAINFRESH CGFE GREENSAND FILTERS FOR REMOVAL OF IRON, MANGANESE & HYDROGEN SULFIDE. Installation & operation instructions

Clean Water Made Easy

Mixing Degas Vessel (MDV) EC-1, EC-2, EC-4, Total Eclipse 2 or 4, and TrioPure-25 or TrioPure-50

Installation and Operation Manual

INSTALLATION AND OPERATING GUIDE Model: EZ 1010-HB High Pressure Garden Hose & Drip Feeder 1 Gallon Liquid / 8LB Dry Capacity

J-PRO-24 Pump Chlorinator. Installation & Start-Up Guide

765 Valve Filters (Taste & Odor, Nextsand, Multimedia, Neutralizer)

Installation, Operation and Maintenance Manual. Infusion Residential Water Softener 169-ISF-1C 169-ISF-2C 169-ISF-3C 169-ISF-4C

FULLY AUTOMATIC WATER SOFTENER

Vacuum-ultraviolet Ozone Systems. Installation & Operation Manual. Model OZ-SPA

Clean Water Made Easy

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Proportional Injector


785 Upflow Water Softener

Parts & Material Included

Transcription:

Genesis Whole House Chlorination System Page 2

Genesis Whole House Chlorination System Page 3 Table of Contents Performance Data and System Specifications................................ 4 Unpacking and Inspection............................................... 4 Genesis Water Powered Injector System Parts List........................... 5 System Installation Diagram............................................. 6 Installation........................................................... 7 Test the Chlorine Level.................................................. 9 Maintenance......................................................... 10 Warranty............................................................ 11

Genesis Whole House Chlorination System Page 4 Performance Data and System Specifications Description Max Flow Rate Minimum Working Pressure Maximum Working Pressure Maximum Vacuum Retention Tank 14 GPM 25 PSI 100 PSI 5 inch/127 mm Hg Operating Temperatures 36 F - 120 F ph Range 6.5-11 Unpacking/Inspection Check the entire shipment for possible damage that may occur in transit. Check all items received against the parts list. Safety Guide Check and comply with all state and local codes which must be followed. Use care when handling and installing the system; do not drop, drag or set on sharp protrusions. Proper Installation Do not install where the system will be exposed to direct sunlight, weather or freezing. Use only lead-free solder/flux for all connections as required by state and federal codes. Install on the main water service line after the pressure tank and/or booster pump. (Do not install in conjunction with a hydro-pneumatic system.) Install the system before the water heater, never run hot water through the system. Install as close as possible to a drain. Additional fittings may be needed to adapt to existing plumbing. WARNING: If this or any other system is installed in a metal (conductive) plumbing system, i.e. copper or galvanized metal, the plastic components of the system will interrupt the continuity of the plumbing system. As a result any errant electricity from improperly grounded appliances downstream or potential galvanic activity in the plumbing system can no longer ground through contiguous metal plumbing. Older homes may have been built in accordance with building codes from decades ago, some of which actually encouraged the grounding of electrical appliances through the plumbing system. Consequently, the installation of a bypass consisting of the same material as the existing plumbing, or a grounded "jumper wire" bridging the equipment and re-establishing the contiguous conductive nature of the plumbing system must be installed prior to your systems use. CAUTION: When adding a filtration/softening system to homes/buildings supplied by well water, the system should be installed following the pressure tank. DO NOT USE this system for pneumatic or hydro pneumatic applications. If you are using a booster pump, then install this system following the booster pump. If you have questions, please c customer service.

Genesis Whole House Chlorination System Page 5 Genesis Water Powered Dosage Injector System Parts List Table 1: Parts List Part Description Qty. Part Description Qty. Chlorine Test Strips 1 Shut-Off Valve: 201-305 Legend PVC Compact Ball Valve 1 15 Gallon Solution Tank 1 Extension Tube 1 Dosage Injector Tubing / Foot Valve 1 Retention Tank 1 Dosage Injector 1

Genesis Whole House Chlorination System Page 6 System Installation Diagram Wall Wall Incoming Water Supply OUT INLET OUTLET IN Dosage Injector Tubing Dosage Injector Carbon Filter ABOVE VIEW Retention Tank Solution Tank Figure 1 Water from Retention Tank Water to House ABOVE VIEW Control Valve Media Tank Carbon Filter Figure 2 Bypass Handle - Allows you to bypass the dosing injector. Flow Direction Arrow - Indicates the proper flow pattern depending on how the unit is install. Dosage Adjustment - Allows you to increase or decrease the amount of solution injected per gallon of flow. Dosage Lock Nut - Locks and unlocks the Dosage Adjustment for increasing and decreasing solution. Suction Hose Nut - Compression nut the secures the injector tubing to the injector. Figure 3 Bypass Handle Flow Direction Arrow Dosage Adjustment Dosage Lock Nut Suction Hose Nut

Genesis Whole House Chlorination System Page 7 Installation Chlorine Injector Pump and Solution Tank Installation Dosage Injector Incoming Water Supply SIDE VIEW Pre-Filter: if sediment is present 15 Gallon Solution Tank Dosage Injector Tubing Foot Valve Outgoing Water to House Control Valve Carbon Filter Figure 4 Chlorine Injector Pump Installation Turn off water supply before any installation steps are performed. 1. Install the Water Powered Dosage Injector on the wall with the mounting bracket in line with the in and out connections of the current water line. Plumb the Water Powered Injector into the water line. Note: Water Powered Injector must be installed after a Pre-Filter (if present) and before all filtration and softener systems. All plumbing lines used between the water powered dosing injector and the inlet of the carbon filter must be of non-corrosive material such as PVC, CPVC or PEX. Check with your local plumbing code. 2. Attach the flexible tubing to the Water Powered Dosage Injector by unscrewing the Suction Hose Nut (Figure 3). Slide the nut over the flexible tubing and attach the tubing to the Suction Hose Nipple. Screw the Suction Hose Nut back on and tighten. Check that the flexible hose is properly installed and not loose. Attach the other end of the flexible tubing with the compression connection to the Pump Tubing on the Solution Tank. Unscrew the compression nut and feed the flexible tube through the nut and onto the line connector, seat fully. Screw the compression nut back on and tighten. Unscrew the other compression nut and place it around the Pump Tubing that is sticking out of the Solution Tank. Insert the Pump tubing into the line connector, seat fully. Screw the compression nut back on and tighten. 3. Fill the Solution Tank with water and bleach, see the chart on page 9 for concentration mixture.

Genesis Whole House Chlorination System Page 8 Retention Tank Installation Side View Retention Tank Extension Tube Shut-Off Valve Figure 5 1. Install the Extension Tube to the 90 degree fitting on the bottom of the Retention tank. 2. Connect the Extension Tube to the Shut-Off Valve. Optional: Connect the Shut-Off Valve to an outgoing drain line. Wall Wall Incoming Water Supply OUT INLET OUTLET IN Chemical Injector Pump Tubing Chemical Injector Pump Outgoing Water ABOVE VIEW Retention Tank Solution Tank Figure 6 3. Connect the water line outflow from the Water Powered Dosage Injector to the Inlet side of the Retention Tank (as seen in Figure 2). Connect the Outlet side of the Retention tank to the Carbon Filter if applicable. (See Carbon Filter manual for installation). 4. Slowly turn on the main water supply and check for leaks.

Genesis Whole House Chlorination System Page 9 Complete the Installation 1. Turn on the main water supply. 2. Check for leaks. Bypass Handle Flow Direction Arrow Injector Body Dosage Adjustment Dosage Lock Nut Suction Hose Nut Test the Chlorine Level 1. Place the Carbon Filter and Water Softener into bypass if existing. 2. Turn on the nearest cold water faucet and let it run for 30 minutes. 3. Check the Water Powered Injector and ensure it is operating. The injector will pulsate as it runs, it will not run when the water is off. 4. Test the water with a chlorine strip after it has run for 30 minutes. The ideal reading for chlorine is 2.6ppm. (If there is no chlorine reading ensure the Carbon Filter and Water Softener are in bypass, check that the system is installed correctly, all lines are clear and not kinked). 5. Depending on the test results use the Dosage Adjustment to increase/decrease the dosage. (The system is preset at.5) Incremental adjustments are made by unlocking the adjustor and turning the Dosage Adjustment to the right 2 full turns to increase and to the left 2 full turns to decrease. Relock the adjustor when adjustment is completed. 6. Repeat steps 1, 2 and 3 to retest the water. 7. Continue the process until the 2.6 ppm reading is acquired. Solution Tank Bleach and Water Ratio Chart Concentration of Bleach (% Sodium Hypochlorite) Ounces of Bleach Gallons of Water 3.00% 79 14 5.25% 6.00% 8.25% 46 40 30 14 14 14

Genesis Whole House Chlorination System Page 10 Maintenance Water Powered Injector: 1. Change Injector Seal Kit Annually (3 O-Rings and Check Valve) Kits are available at DiscountWaterSofteners.com Solution Tank Refill Bleach & Water 1. Check the level of the Solution Tank twice per month. Do not let the liquid in the tank fall below ¼ full. 2. Fill the Solution Tank with bleach and treated water as needed. (Water that has gone through your filtrat ion system).

Genesis Whole House Chlorination System Page 11 Warranty Discount Water Softeners will provide for replacement of all parts shown to be defective in material or workmanship during a period of twelve months from the date of purchase by the original purchaser. To obtain warranty replacement of a part, the unit must be returned with original proof of purchase receipt to Discount Water Softeners and thereafter recognized as defective after examination by the technical services of the aforementioned company. The unit must be sent to Discount Water Softeners prepaid, but will be returned free of charge if found to be covered by the warranty and repairs are made. This warranty only covers circumstances where the part has failed due to defects caused by the manufacturing process. This warranty is invalid if the defects are found to be due to the product s misuse, inappropriate use of tools, lack of maintenance or defective installation or environmental accidents or corrosion by foreign bodies and liquids found within or in proximity to the unit. The seals and o rings are not covered under this warranty, nor is damage to the unit caused by water impurities such as sand. A filter (80 microns or less) must be used in front of the unit for the warranty to be valid. The aforementioned company declines any responsibility if the unit is used under conditions outside of its operating tolerance as indicated herein. Please reference the Carbon Filter manual for warranty information on that product.