IM 77J01H07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0

Similar documents
IM 77J01A07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0. Output-2 signal

User s. Manual) Model VJS7 Potentiometer Converter (Multi-function) (Isolated Single-output and Isolated Dualoutput

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

User s. Manual) Model VJUK Limit Alarm for Universal Input

User s Manual. Model VJRK IM 77J01R21-01E 1. CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT 4. MODEL AND SUFFIX CODES 5.

General Specifications

DIGITAL INDICATOR JIR-301-M

Series Temperature Controller Instruction Sheet

General Specifications

Instruction manual Temperature Controller KT7

Series Digital Controller Instruction Sheet

RS485 MODBUS Module 8AI

ISOLATOR SGI SGIW INSTRUCTION MANUAL

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Process & TeMPerATUre UniversAl input DigiTAl MeTers

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

Warning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Advanced Ultraviolet Burner Controller

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

Temperature Controllers

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

Instruction manual for DIN rail mounting type indicating controller DCL-33A

Carbon Monoxide Transmitter

Analog Room Pressure Monitor RPC Series

02/11/2015

CU-02 with Senaco Plus

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

Multi-Gas-Controller MGC2

CLEANROOM MONITOR CR3A Network - Installation Instructions

02/11/2015

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL

DIN RAIL MOUNTED INDICATING CONTOLLER DCL-33A INSTRUCTION MANUAL

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

I/A Series 716C 1/16 DIN Temperature Controller

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Infrared Moisture Determination Balance FD-610. Operating Manual

Instruction Manual August sitrans CU 02

DCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.

Indoor Oxygen Monitor OX-600 Operating Manual

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

AE500 Instruction Manual

User Guide. DATUM L150 Panel-Mounted Universal Level Indicator A1. ABB Instrumentation

Digital Panel Meters 47 Series. DC INPUT DIGITAL PANEL METER (4 1/2 digit, LED display type) Model: 47LV OPERATING MANUAL

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

DIGITAL INDICATOR DI25

Installation Manual Tracker 221

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

WIO200 Water In Oil measuring instrument

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

47LV BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL DC INPUT DIGITAL PANEL METER MODEL. (4 1/2 digit, LED display type)

Buzzer Unit. TAN-5000 Series. Operating Manual

ME 3011C / Alarm Indication / Quick Reference Guide

Class 1 laser beam sensor safe for your eyes

CHILLGARD M-100. Refrigerant Sensor. Operating Manual. Order No.: /02

SHIMADEN DIGITAL INDICATORS

Operating Manual TR600

INSTRUCTION MANUAL Micro-computer based digital indicating controller

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Series SHR-5620 Digital Display Volumetric Meter Operation Instruction

Software Version 2.01 LEVEL MONITOR MODEL 220

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Digital Heater Element Burnout Detector K8AC-H

CTT8 TEMPERATURE MONITOR DEVICE

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

OPTISENS TUR 2000 Technical Datasheet

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200

Pump-Up Controller MODEL 4062

UDC 700 Universal Digital Controllers and Indicator Specifications

Ionizer (Static Remover) STABLO-EX Instruction Manual

Process Alarm Module RTA 421

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

User Guide IM/L160_6. Wall-/Pipe-mount Level Indicator L160

Class 1 laser beam sensor safe for your eyes

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

MICROJET RECORDER (180mm)

2-wire Passive Intelligent Loop (LED) Display Meter

1. Model ACS 1 3 A / A, Series name: ACS-13A- /A (W48 x H48 x D62mm) Control action 3 PID A1 A Alarm type can be selected by keypad.

Instruction manual Micro-computer based digital indicating controller

PTE0705 Electric Fence Monitor

F4 Process Controller Installation and Operation Guide

Pump-Down Controller MODEL 4052

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

MICRO CONTROLLER S Z SERIES

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

MO n : 12JMC rév A

PLC INTERFACE UNIT CIT-200 INSTRUCTION MANUAL

BC3250. Blowdown Controller

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

Instruction Manual December 2001 ENACOCU02

DMFPM-2R MULTIFUNCTIONAL

Transcription:

User s Manual Model VJH Isolator (Multi-function) (Isolated Single-output and Isolated Dual-output Types) --, Naka-cho Musashino-shi, Tokyo 80-80 Japan Thank you for purchasing the JUXTA Signal Conditioner. Please read through this manual before use for correct handling. You can download the latest manuals from the following website: http://www.yokogawa.com/ns/juxta/im/ IM J0H0-0E st Edition Nov. 4th Edition Feb. 0 ARY NOTES FOR SAFE USE OF THE PRODUCT This User s Manual should be carefully read before installing and operating the product. Please keep this User s Manual for future reference. For more information of the safety precautions, please refer to the Precautions on the Use of the JUXTA Series (IM J0A00-Z). The related manuals and general specifications are shown in the table below. Doc. Name Doc. Number Precautions on the Use of the JUXTA Series (User s Manual) IM J0A00-Z Model VJH Isolator (User s Manual) IM J0H0-0E (This manual) Model VJH Isolator (General Specifications) GS J0H0-0E User s manuals in the above table are essential parts of the product; keep it in a safe place for future reference. This manual is intended for the following personnel; Engineers responsible for installation, wiring, and maintenance of the equipment. Personnel responsible for normal daily operation of the equipment. The following symbol is used on the product and in this manual to ensure safe usage. WARNING Calls attention to actions or conditions that could cause serious or fatal injury to the user, and indicates precautions that should be taken to prevent such occurrences. Calls attention to actions or conditions that could cause injury to the user or damage to the instrument or property and indicates precautions that should be taken to prevent such occurrences. CHECKING PRODUCT SPECIFICATIONS AND THE CONTENTS OF PACKING () Model Number and Specification Check Check that the model number and specifications shown on the nameplate attached on the side of the product are as ordered. () Contents of the Packing Check that the packing contains the following items: VJH: unit Standard Accessories: Tag number label: sheet Range label: sheet Shunt registor (for specification of current input): piece User s manual (IM J0H0-0E, this manual): copy User s manual (IM J0A00-Z): copy GENERAL This plug-in isolator, which belongs to the JUXTA series of signal conditioners, receives DC current or voltage signals and converts them to pairs of isolated DC voltage or current signals. Output- signal is selectable from a DC voltage signal, DC current signal, communication function (RS-48), and alarm output (two relay contacts). (Isolated Dual-output Type) Various parameters such as input range can be set and modified using a PC (VJ(sold separately)) or Handy Terminal (JHT00(sold separately) and the like). MODEL AND SUFFIX CODES Model Suffix codes Description VJH -0 x x -x x x 0 /x Isolator (Multi-function) Fixed -0 Always -0 code Output output configuration outputs 00-40 V AC/DC -0 V DC * Input signal A 4 to 0 ma DC Output- signal to V DC Z (Custom order) * A 4 to 0 ma DC to V DC Output- signal P Communication function (RS48) T Alarm output ( relay contacts) N No output- Fixed code 0 Always 0 /SN No socket (with socket if not specified) Option /C0 HumiSeal coating *4 /FB Fuse bypass *4 *: Operating range: 8 to 4V AC/DC *: Operating range: to V DC *: DC voltage signal or DC current signal *4: When option code /C0 or /FB is specified, the conformity to the safety and EMC standards is excluded. CE marking is not applicable. -A 0 to 0 ma DC, span is ma or more - -0 to 0 V DC, span is 0. V or more. MOUNTING METHODS Plug/disconnect the main unit into/from the socket vertically to the socket face. Otherwise the terminals may bend and it may cause bad contact. The converter shall not tilt degrees or more in either direction when installed. When the converter is not connected to the socket, it is necessary to protect the socket against ingress of dust to the connector part. Keep this product in a conductive bag when plugged out, during transport or storage.

. Wall Mounting Loosen the main unit-fixing screw of the isolator to disconnect the main unit from the socket. Next, anchor the socket onto the wall with screws. Then, plug the main unit into the socket and secure the main unit with the main unit-fixing screw. Mounting Dimensions Mounting screws Main unit ±0. Threaded hole for fixing the main unit Main unit-fixing screw Socket. or more Unit: mm ±0. -M4 or -ø4. or more. DIN Rail Mounting Locate the isolator so that the fits into the upper part of the DIN-rail groove at the rear of the socket, and fasten the socket using the slide lock at the lower part of the socket. Push Fit into here (Rear of socket) Slide lock. Mounting Using a Multi-mounting Base For mounting using a multi-mounting base, see the Instruction Manual for VJCE (VJ Mounting Base)..4 Using Ducts Wiring ducts should be installed at least 0 mm away from the top or bottom of the main unit.. INSTALLATION LOCATION Avoid the following environments for installation locations: Areas with vibrations, corrosive gases, dust, water, oil, solvents, direct sunlight, radiation, a strong electric field, and/or a strong magnetic field, direct radiant heat, wind, temperature fluctuation,,000 m or more above sea level. If there is any risk of a surge being induced into the power line and/or signal lines due to lightning or other factors, a dedicated lightning arrester should be used as protection for both the product and a field-installed device. Operating temperature/humidity range: -0 to C (-0 to 4 C for side-by-side mounting*)/ to 0%RH (no condensation) * If the previous model (style S.xx earlier) is installed together, the ambient temperature is 0 to 40 C. Continuous vibration: (at to Hz) Half amplitude of mm or less (at to 0 Hz).8m/s or less, oct/min for 0 minutes each in the three axis directions Impact: 8 m/s or less, ms, axes, directions, times each. EXTERNAL WIRING WARNING To avoid the risk of an electric shock, turn off the power supply and use a tester or similar device to ensure that no power is supplied to a cable to be connected, before carrying out wiring work. Do not operate the product in the presence of flammable or explosive gases or vapors. To do so is highly dangerous. Use of the product ignoring the specifications may cause overheating or damage. Before turning on the power, ensure the following: voltage and input signal value applied to the product should meet the required specifications. The external wiring to the terminals and wiring to ground are as specifications. Wiring should be connected to the terminals on the socket of the product. The terminals for external connections are of M screws. Use crimp-on terminal lugs for connections to the terminals. Recommended cables: A nominal cross-sectional area of 0. mm or thicker for signal cables, and that of. mm or thicker for power cables. Shunt resistor (Externally connected for current input) Output- signal Input RS-48 Analog output Alarm output communication ALM B R A R: Externally connected for current input 0 8 L N GND 8 0 Output- signal Analog output ALM Do not use output- for the isolated single-output type. The power line and input/output signal lines should be installed away from noise-generating sources. Other wise accuracy cannot be guaranteed. Make sure to earth ground the ground terminal through minimum resistance. The length and thickness of the grounding cable should be as short and thick as possible. Directly connect the lead from the ground terminal (terminal no. 8) of the product to the ground. Do not carry out daisychained inter-ground terminal wiring. The product is sensitive to static electricity; exercise care in operating it. Before you operate the product, touch a nearby metal part to discharge static electricity. The use of inductance (L) loads such as auxiliary relays and solenoid valves causes malfunction or relay failure; always insert a CR filter or diode for spark-removal into the line in parallel with the load. Recommended CR C: 0. to µf against contact current A R: 0. to Ω against contact voltage V If the ambient temperature is 0 C or more, please use the cable that the rated temperature is 0 C or more. 4. DESCRIPTION OF FRONT PANEL AND CONNECTION OF HANDY TERMINAL 4. Front Panel The communications connector in the front panel is used for setting up parameters through the Handy Terminal. The alarm- and alarm- LEDs light up if an alarm occurs (those LEDs are provided only when the output- is specified for alarm output (the output- suffix code is T).) Communication connector Alarm indicator lamp (for alarm ) Alarm indicator lamp (for alarm ) IM J0H0-0E 4th Edition Feb.0 0-00

4. Connecting the Handy Terminal Use the connector for communication when setting the parameters using a PC (VJ Parameters Setting Tool) or the Handy Terminal. < How to connect with the setting tool> <How to connect with the setting tool> PC with the VJ installed JHT00 Handy Terminal JUXTA communication cable with -pin connector Dedicated cable Dedicated adapter Modular jack conversion adapter JUXTA VJ Series Use the VJ of version R.0.0 or later. The modular jack conversion adapter does not come with the JHT00 Handy Terminal. It is sold separately.. SETTING PARAMETERS Set the parameters using a PC (VJ Parameter Setting Tool) or the Handy Terminal. Refer to. LIST OF PARAMETERS in this manual and the User s Manual for VJ PC-based Parameters Setting Tool (IM J0J-0E) or the User s Manual for JHT00 Handy Terminal (IM J0H0-0EN).. Settings Related to Inputs and Outputs.. Input Type Set by selecting input type from among VOLTS (DC voltage) and CURRENT (DC current) in [D: INP TYPE]... Input Range Set the 0% value of input range to [D4: INPUT L_RNG] and the 00% value of input range to [D: INPUT H_RNG] within the numerically specified range. NOTE In case the input range is changed after factory-ship, the instrument may not work within the rated accuracy range depending on the changed input range. Perform the adjustment following the maintenance of this instruction manual after changing the input range... Software Filter Set the software filter in [D: S/W FILTER]. OFF, LOW, MIDDLE, HIGH (default value: OFF) When LOW, MIDDLE, or HIGH is selected, a first-order filter equivalent to 00 ms, 00 ms, or s is inserted in the input...4 Direction of Output Action Analog output signals can be reversed. To reverse the signal from output-, set [D0: OUT DR] to REVERSE. For output-, set [D OUT DR] to REVERSE. To return the output- signal to normal, set [D0: OUT DR] to DIRECT. For output-, set [D: OUT DR] to DIRECT... External Input Resistance Correction For current input, set the external resistance to [D: IN RESIST]. There is a difference between this value and the actual external resistance. If this difference causes an error, the input can be corrected. To perform correction, wire as shown in the figure below, apply a stable input equivalent to 00%, and set [P40:RESISTOR ADJ] to EXECUTE. If you need perform correction again such as when the external resistance is changed, reset the correct value. To do so, set [P40: RESISTOR ADJ] to RESET. A current generator R VJH R:External resistor. Settings Related to Communication Function Set the following parameters when output- is specified for communication function. For more information on the communication function, see the Instruction Manual for VJ Series Communication Function (IM JJ-0E)... Communication Protocol Set the communication protocol by selecting from among PC- LINK, PC-LINK WITH SUM, MODBUS ASCII, MODBUS RTU, and LADDER in [F0: PROTOCOL]... Communication Address Set the address number of the isolator numerically in a range of to in [F0: ADDRESS]... Baud Rate Set the baud rate by selecting from among 00, 400, 4800, 00, 00 and 8400 bps in [F0: BAUD RATE]...4 Parity Select and set NONE, EVEN, or ODD in [F04: PARITY]... Data Length Select and set bits or 8 bits in [F0: DATA LEN]... Stop Bit Select and set bit or bits in [F0: STOP BIT]... Input Decimal Point Position Number of digits of decimal places (setting of D register [D000]) can be set. Select and set among 0 to digits in [F0: INPUT DEC PT].. Settings Related to Alarm Output Set the following parameters when output- is specified for alarm output... Alarm Setpoints Set the alarm setpoints of alarm- and alarm- in [E0: SET POINT] and [E04: SET POINT] numerically. Setting range: A range of 0 to 00% of input range Setting resolution: 0.%.. Direction of Alarm Action Select the direction of alarm- action and that of alarm- action from among HIGH ALM (high-limit alarm) and LOW ALM (low-limit alarm) and set each in [E0: ALM ACTION] (direction of alarm- action) or [E0: ALM ACTION] (direction of alarm- action). To activate alarm status when input signal alarm setpoint, select HIGH ALM. To activate alarm status when input signal alarm setpoint, select LOW ALM... Hysteresis Set alarm- and alarm- hysteresis, in [E0: HYSTERESIS] and [E0: HYSTERESIS]. Hysteresis is a value added to the alarm setpoint in order for an alarm status to be released (to normal) after the alarm status has been activated. The alarm status will be released in the following conditions, depending on the direction of alarm action. * When HIGH ALM (high-limit alarm) is set: Alarm is released when input signal < (alarm setpoint - hysteresis). * When LOW ALM (low-limit alarm) is set: Alarm is released when input signal > (alarm setpoint hysteresis). Setting range: A range of 0 to 00% of input range Setting resolution: 0.%..4 Alarm ON Delay and Alarm OFF Delay Set alarm- and alarm- ON delays in [E: ON DELAY] and [E: ON DELAY] and then alarm- and alarm- OFF delays in [E: OFF DELAY] and [E4: OFF DELAY]. An alarm ON delay is a delay time from the establishment of alarm condition to alarm output; an alarm OFF delay is a delay time from the establishment of return-to-normal condition to output. Setting range: 0 to seconds Setting resolution: second (Note that about 0. second will be added to set time to prevent erroneous operation.) For example, when an alarm ON delay is set to second, alarm output is generated if alarm status continues for more than second after the input value exceeds the alarm setpoint. Further, when an alarm OFF delay is set to seconds, alarm output is released if normal condition continues for more than seconds after the input value has returned to normal from the alarm status. IM J0H0-0E 4th Edition Feb.0 0-00

.. Direction of Relay Action Set the direction of relay energizing in alarm- normal condition and alarm- normal condition by selecting from among NRM DE-ENERGIZED (de-energized under normal condition) and NRM ENERGIZED (energized under normal condition) in [E: RL ACTION] and [E: RL ACTION] and set them.. DESCRIPTION OF ALARM ACTIONS This chapter describes examples of alarm actions under the following conditions. Item Alarm Alarm Parameter Setpoint Parameter Setpoint Direction of alarm action E0: ALM ACTION High-limit alarm E0: ALM ACTION Low-limit alarm Alarm setting E0: SET POINT 80% E04 : SET POINT % Hysteresis E0: HYSTERESIS 0% E0 : HYSTERESIS % Alarm ON delay E: ON DELAY sec E : ON DELAY sec Alarm OFF delay E: OFF DELAY sec E4 : OFF DELAY 4 sec Description of alarm actions Figure. [%] 00 80 0 40 0 0 s. s. Alarm- hysteresis (%) Alarm- action Alarm- action Alarm The alarm is output if the condition where the input value is 80% or more of high-limit alarm continues for second or more. After the alarm is output, when the condition where the input value is less than 0% of high-limit alarm continues for seconds or more, the status returns to normal. Alarm- setpoint (%) Alarm- setpoint (80%) Alarm- hysteresis (0%) The alarm is output if the condition where the input value is % or less of low-limit alarm continues for seconds or more. After the alarm is output, when the condition where the input value is more than 0% of low-limit alarm continues for 4 seconds or more, the status returns to normal. [] Alarm status does not continue for more than second after the alarm conditions are established at alarm. [] status does not continue for more than seconds after the normal conditions are established at alarm. [] Alarm status does not continue for more than seconds after the alarm conditions are established at alarm. [4] status does not continue for more than 4 seconds after the normal conditions are established at alarm. Alarm conditions established High-limit alarm ON conditions established [] [] High-limit alarm OFF Alarm- ON delay Alarm- OFF delay Low-limit alarm ON Low-limit alarm OFF Alarm conditions conditions established established Alarm- Alarm- [] ON delay [4] OFF delay s. 4 s. Alarm Elapsed time s.. LIST OF PARAMETERS Parameter Display Item MODEL Model TAG NO Tag no. SELF CHK Self-check result A DISPLAY Display * A0 INPUT Input value A0 OUTPUT Output value A0 OUTPUT Output value A ALM STATUS Alarm- status A ALM STATUS Alarm- status A4 STATUS Status * A REV NO Rev. no. A8 MENU REV MENU REV A0 SELF CHK Self-check result B DISPLAY Display * B0 INPUT Input value B0 OUTPUT Output value B0 OUTPUT Output value B ALM STATUS Alarm- status B ALM STATUS Alarm- status B0 SELF CHK Self-check result D SET (I/O) Setting (I/O) * D0 TAG NO. Tag no. D0 TAG NO. Tag no. D0 MENT Comment D04 MENT Comment D INP TYPE Input type D IN RESIST Input resistance D4 INPUT L_RNG Input low range D INPUT H_RNG Input high range D OUT L_RNG Output- low range * D OUT H_RNG Output- high range * D4 OUT L_RNG Output- low range * D OUT H_RNG Output- high range * D0 OUT DR Direction of output- action D OUT DR Direction of output- action D S/W FILTER Software filter D NMRR Frequency setting * D0 SELF CHK Self-check result E SET(ALM) Setting (alarm output) * E0 SET POINT Alarm- setting (%) E04 SET POINT Alarm- setting (%) E0 ALM ACTION Direction of alarm- action E0 ALM ACTION Direction of alarm- action E0 HYSTERESIS Alarm- hysteresis (%) E0 HYSTERESIS Alarm- hysteresis (%) E ON DELAY Alarm- ON delay setting E ON DELAY Alarm- ON delay setting E OFF DELAY Alarm- OFF delay setting E4 OFF DELAY Alarm- OFF delay setting E RL ACTION Direction of alarm- relay action E RL ACTION Direction of alarm- relay action E0 SELF CHK Self-check result F SET() Setting (communication) * F0 PROTOCOL Communication protocol F0 ADDRESS Address F0 BAUD RATE Baud rate F04 PARITY Parity F0 DATA LEN Data Length F0 STOP BIT Stop bit F0 INPUT DEC PT Decimal point position of input F0 SELF CHK Self-check result P ADJUST Adjustment * P04 IN ZERO ADJ Zero adjustment of input- P0 IN SPAN ADJ Span adjustment of input- P0 OUTZERO ADJ Zero adjustment of output- P OUTSPAN ADJ Span adjustment of output- P OUTZERO ADJ Zero adjustment of output- P OUTSPAN ADJ Span adjustment of output- P40 RESISTOR ADJ Adjustment of external input resistance P0 SELF CHK Self-check result Q TEST Test * Q04 OUT TEST Forced output (output-) Q0 OUT TEST Forced output (output-) Q0 ALM TEST Forced output (alarm ) Q ALM TEST Forced output (alarm ) Q0 SELF CHK Self-check result * The Status is displayed for service personnel to see history records. * There are items not displayed depending on what output- is specified. * The parameters are the items to be set at the factory. 4 IM J0H0-0E 4th Edition Feb.0 0-00

8. MAINTENANCE The product starts running immediately when the power is turned on; however, it needs 0 to minutes of warm-up before it meets the specified performance. For cleaning the instrument, use a soft and dry cloth. 8. Calibration Apparatus A voltage and current generator (YOKOGAWA GS00 or the equivalent) Digital Multimeter (YOKOGAWA or equivalent): A precision resistor of 0 Ω ± 0.0%, W (for current output) Setting tool for adjustment (Refer to 4. Connecting the Setting Tools in this manual.) 8. Calibration Procedure. Connect the instruments as shown in figure below. First adjust the output- signal and then the output- signal. External receiving resistor (Shunt resistor) for current input Output- Input Voltage and current generator R: External receiving resistor for current input 0 8 L N GND 8 0 4 R Alarm- ALM Alarm- ALM Output- R R: For current output using 0 Ω precision resistor. Produce input signals equivalent to 0,, 0,, and 00% of the input span from the voltage and current generator to the isolator.. Then, check that the isolator s output signal shows voltages corresponding to 0,, 0,, and 00% of the input span within the rated accuracy range. For alarm output, check the relay action by the alarm indicator lamp or resistance of output terminals. If the output signal is out of the rated accuracy range, adjust the output signal level using the Handy Terminal (JHT00). For adjustment using a setting tool, refer to the User s Manual for each setting tool and. List of Parameters in this manual. User s Manual for VJ [Document No.: IM J0J-0E]; User s Manual for JHT00 [Document No.: IM J0H0-0EN]. SAFETY AND EMC STANDARDS The following will be acquired. Safety: IEC/EN 00- compliance (CE), IEC/EN 00--00 compliance (CE) CAN/CSA C. No.00- compliance (CSA) UL00- (CSA NRTL/C) Installation category II Pollution degree Measurement category O (other) Rated measurement input voltage: ±0 V DC max. Rated transient overvoltage: 00 V (*) * This is a reference safety standard value for Measurement Category I of CSA/UL00- and Measurement Category O of EN 00--00. This value is not necessarily a guarantee of instrument performance. Entrance Cable IV Internal Wiring III T O Outlet Measurement Description category O (other) For measurements performed on circuits not directly connected to MAINS. II CAT.II For measurements performed on circuits directly connected to the low-voltage installation. III IV CAT.III For measurements performed in the building installation. CAT.IV For measurements performed at the source of the low-voltage installation. II Remarks Appliances, portable equipments, etc. Distribution board, circuit breaker, etc. Overhead wire, cable systems, etc. EMC standards: CE marking: EN - Class A, Table EN -- * The instrument continues to operate at a measurement accuracy of within ±0% of the range during testing. EN 0 Class A Group EN 000-- Class A EN 000-- EMC Regulatory Arrangement in Australia and New Zealand (RCM): EN 0 Class A, Group KC marking: Electromagnetic wave interference prevention standard, electromagnetic wave protection standard compliance Caution to comply with EMC standards: When operating this instrument by external power supply, use an independent power unit conforming to CEmarking. Be sure to use the lightning arrester to comply EMC standards. Note: When option code /C0 or /FB is specified, the conformity to the safety and EMC standards is excluded. 0. ENVIRONMENT STANDARD RoHS Directive: EN 08 (However, when option code /C0 or /FB is specified, CE marking is not applicable because the product does not comply with the Safety and EMC standards.). TRANSPORT AND STORAGE CONDITIONS Temperature: - to 0 C Temperature change rate: 0 C per hour or less Humidity: to %RH (no condensation) Keep this product in a conductive bag when plugged out, during transport or storage. This instrument is for Measurement Category O (other). Do not use it for measurements in locations falling under Measurement Categories II, III, and IV. IM J0H0-0E 4th Edition Feb.0 0-00