Installation Settings Guide

Similar documents
Installation Settings Guide

Homeowner s Guide / 1

PRO Installation. Thermostat Wi-Fi

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page.

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

Smart Hub THERMOSTAT. Installation Manual

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

T-32-TS Touchscreen Thermostat. Installation Manual

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

INSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide.

Models: 1F95U-42WF, ST75 Version: October Sensi TM. Touch Wi-Fi Thermostat MANUAL OPERATION GUIDE

Installation, Programming and Operating Guide for Digital, Programmable Thermostat with Smart Fan Technology. with SFT (Smart Fan Technology )

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.

Installer Guide. WARNING Important Safety Information. 1 Specifications

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page.

PRO Installation. Touch Wi-Fi Thermostat

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page.

5+2 Day. up to HEAT COOL

SAS6000UTK-7 UNIVERSAL THERMOSTAT

7-DAY or 5/2-DAY PROGRAMMABLE, OR NON-PROGRAMMABLE THERMOSTAT INSTALLATION AND OPERATING INSTRUCTIONS

Smart thermostat with Humidification/De-humidification control

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

PRO Installation. Touch Wi-Fi Thermostat

Smart THERMOSTAT. Installation Manual

AMANA PHWT-A200 THERMOSTAT

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

Installer Guide. WARNING Important Safety Information. 1 Specifications

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE

7-Day. Digital Thermostat. residential. & 2-cool

HEAT COOL. Meets Commercial California Title 24

Operation 8085C ENGLISH. Customer Support: or Visit our webiste Printed in China

Siemens RDY2000BN. Start Up Guide

Programmable Digital Thermostat

SC Installation, Operation & Application Guide

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

OWNER S MANUAL Venstar Inc. 08/07

Safety & Installation Instructions

OWNER S MANUAL Venstar Inc. 08/07

OWNER S MANUAL. Part Number P CONTENTS

I2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

1 For All Programmable Digital Thermostat

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

SC Installation, Operation & Application Guide

Safety & Installation Instructions

Owner s Manual. Part Number 33CS250-01

MODEL TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

Z100 Pioneer 2 Smart Thermostat Operating and Installation Manual

1 For All Programmable Digital Thermostat. Meets Residential California Title 24

Auto-Changeover: Cool Setpoint: Deadband: Dehumidify: Differential: Heat Setpoint: Humidify: Icon: Mode: Non-Programmable Thermostat:

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

XR401. Comfort Control TCONT401AN21MA. Owner s Manual. your local dealer (distributor) For more information contact. Tyler, Texas 75711

Safety & Installation Instructions

Instruction Guide: Thermostat Operation

OWNER S MANUAL. Part Number P

Indicates incorrect room temperature. No second stage or AUX heating. Emergency heat does not turn on

2018 thesimple, Inc.

Smart Temp. ApolloP/n Installation Manual. Version 1.0

ETN-24-SUPER-PROG (US Program - Celsius)

OWNER S MANUAL Venstar Inc. 08/07

SC Installation, Operation & Application Guide

TH146-P-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.

PS4000 and PS5000 Touchscreen Programmable Thermostat Installation and Owners Manual Robertshaw 01/

Pioneer Z100 Smart Thermostat Operating and Installation Manual

Comfort System T-21-P Touchscreen Thermostat Installation Manual

FMT24-SUPER-2S-FP-PROG-F Owner s manual & Technician Settings. Installation

HEAT HEAT HEAT COOL COOL

User s Manual ELITE PROGRAMMABLE THERMOSTAT WITH MENU DRIVEN DISPLAY

WARNING Important Safety Information

TH146-N-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.

SAS6000UTK-7-WIFI OPERATING INSTRUCTION

Carrier NON-PROGRAMMABLE DIGITAL THERMOSTAT. Dual Setpoint Thermoglow Backlight No Batteries Required Auto Changeover Locking Keypad

Safety & Installation Instructions

OPERATING MANUAL. Need Help? This manual covers the following models: T915. Table of Contents

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

SMART TEMP UNIVERSAL 7-DAY PROGRAMMABLE THERMOSTAT (FOR BOTH CONVENTIONAL AND HEAT PUMP SYSTEMS) INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Owner s Manual. Part Number 33CSSP2-FC BACK LIT LIQUID CRYSTAL DISPLAY MODE BUTTON

RTH8500 Series. Quick Installation Guide. Included in your box. Programmable Thermostat. Quick Install Guide Screws and anchors. RTH8500 Thermostat

(-)HC-TST213UNMS 5/1/1 Day 5/2 Day Non-Programmable. Yes

FOR BOTH CONVENTIONAL AND HEAT PUMP SYSTEMS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT!

Installation, Start-Up, and Operating Instructions

TCONT402AN32DA. Owner s Manual. Comfort Control XR402. Pub. No Fan Mode. Filter/OD

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

DAY/TIME Button: Selects hour, minute and day setting.

Pioneer Z100 Smart Thermostat Operating and Installation Manual

Owner s Manual. Part Number 33CS250-FS and 33CS220-FS

Programmable Thermostat. Installation, Operation and Maintenance Manual Effective January 2017

RC-2000 Thermostat Installation Instructions

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

SMART 1000 Touchscreen Thermostat Installation Manual

2017 EcoFactor, Inc.

Advanced Installation and Configuration Instructions

Installation Instructions

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

INSTALLATION INSTRUCTIONS

OPERATING MANUAL. This manual covers TopTech models: TT-S-855 and T855

Commercial Touchscreen Thermostat

DAY/TIME Button: Selects hour, minute and day setting.

Owner s Manual. Part Number 33CSCPACHP-01

INSTRUCTION MANUAL. PUREPRO DP732T 3 Heating and 2 Cooling with Automatic Humidity Control and Dual Fuel Switch 3-YEAR WARRANTY

Transcription:

In this guide we will describe the advanced installation settings that you can access from KONO Smart s main menu. We recommend that an HVAC service professional uses these settings to fine-tune your thermostat s performance for your home. You can access the installation settings by going to the main menu and selecting the gear icon. You will see IS on the screen and will be prompted to select yes or no. Select yes to access the installation settings. There are three ways to exit the settings: 1. Continue through the remaining settings until you pass setting 99. 2. Press and hold the knob for 3 seconds after you confirm any changes to your settings. 3. Wait 60 seconds after you confirm any changes to your settings. System Type & Configuration You will first see your current system type and configuration confirm by pressing the knob and then you will begin navigating through the available settings. HVAC system type F = Furnace HP = Heat Pump Available System Modes Furnace systems: HVAC system subtype ELEC: Electric fan. Thermostat calls fan to run with heat GAS: Gas fan. Thermostat does not call fan to run with heat BOIL: Boiler. No fan connected to heating system Heat Pump o: Changeover valve = o b: Changeover valve = B

-01 Temperature Format Use this setting to select your preferred temperature format. F for Fahrenheit C for Celcius -02 Temperature Calibration KONO Smart is factory calibrated, but you can use this setting to adjust the temperature sensor for your home. The screen will alternate between your calibration temperature and the offset value to remove calibration, make sure that the offset value is set to 0. -03 Available HVAC Modes KONO Smart uses terminal detection to identify your system type and you can use this installation setting to view and change the available modes. Use this setting to view and/or change the different modes available depending on your system type. Rotate the knob to see various options and configurations for your system. Auto Heat & Cool Heat Only Cool Only

-04 Heat Limit Use this setting to set a maximum temperature limit for your heating system. The limit can be as high as 90F (32C) or as low as 60F (15C). Maximum Heat Limit Minimum Heat Limit -05 Cool Limit Use this setting to set a minimum temperature limit for your cooling system. The limit can be as high as 75F (24C) or as low as 45F (7C). Cool Maximum Cool Minimum -06 System Type Use this setting to modify the system type. The available options include Gas Furnace, Electric Furnace, Boiler (No Fan) and Heat Pump. See step 07 below for additional options when selecting Heat Pump. Gas Furnace Electric Furnace Boiler (No Fan)

-07 System Type - Heat Pump If you selected heat pump during #6, you will then have to select your valve type in #7. Select O or B depending on your valve type. B will energize the B/O terminal in heat mode and O will energize the B/O terminal in cool mode. Heat Pump option -08 Minimum On/Off Time Use this setting to set a standby time so that your HVAC systems can safely and efficiently switch on and off. You can either select a 5-minute or a 2-minute off time. During normal operation, the hourglass icon indicates that the minimum off time is temporarily preventing your heating and cooling system from turning on. -09 Temperature Swing Use this setting to set a swing value. Your swing setting determines how far the ambient temperature can deviate from the set temperature before KONO Smart turns on your heating or cooling system. You can select 0,.25,.5, 1 or 2.25.

-10 Stage 2 Heating Offset (for conventional systems) Use this setting to set a value that your thermostat will use to decide when to turn on your second stage of heating. You can select Off, 1, 2, 3, 4 or 5. Off, no second stage heat 1 5-11 Stage 2 (Auxiliary) Heating Offset (for heat pump systems) Use this setting to set a value that your thermostat will use to decide when to turn on your second stage of heating. You can select Off, 1, 2, 3, 4 or 5. Off, no second stage heat 1 5-12 Clock Offset Use this setting to choose between 12-hour am/pm time display or 24-hour time display.

-13 Backlight Use this setting to choose between a backlight auto-off setting of 10 seconds or an always-on backlight. When the backlight is turned off the display will not be visible. Press the knob to turn on the display. 10 Seconds Always On -14 Dual Fuel (for heat pump systems) Use this setting to turn the Dual Fuel option ON or OFF. When set to ON, the balance points defined in menus 15 and 16 will be used to determine use of compressor and auxiliary heat stages. When set to OFF, the outside air temperature will not be used to determine staging rules. Dual Fuel On Dual Fuel Off -15 Balance Point High Use this setting to specify an outdoor air temperature above which your auxiliary heat source will be disabled. If the outdoor temperature goes above this set point, only the compressor heat source will be used. 32 F (0 C) 99 F (37 C)

-16 Balance Point Low Use this setting to specify an outdoor air temperature below which your compressor will be disabled. If the outdoor temperature goes below this set point, only the auxiliary heat source will be used. 1 F (-18 C) 77 F (25 C) -17 Filter Life Use this setting to turn on and set a value for your air filter s lifespan. You ll then be able to check its remaining lifespan in the fan settings submenu. (You can select Off, 30, 60, 90, 120, 180 or 365 days). Off 30 Days 365 Days -98 Compressor Bypass Use this setting to temporarily disable the minimum on/ off time protection. If you set compressor bypass protection to yes then your system will switch heating and cooling on/off without waiting for the minimum on/off time. Compressor Bypass On Compressor Bypass Off

-99 Factory Reset Use this setting to initiate a factory reset and to setup your KONO Smart from scratch. Reset KONO Do Not Reset KONO -Additional Features Lock: Press and hold the knob for 10 seconds on the main run screen to lock local control of KONO Smart. When locked, press and hold the knob for 10 seconds to unlock. Power Cycle: Remove KONO Smart from its base and locate the black reset button on the back of the thermostat. Press and hold this button for 3 seconds to fully power cycle the device. EMER Heat: If you have a Heat Pump system with stage 2 (auxiliary) heat enabled, you can select EMER heat from the mode menu. When this is enabled, the thermostat will not use the compressor heating stage and will use the auxiliary heating stage as the only heat source. For wiring diagrams, please reference the appendix section of the KONO Smart Installation Manual We re here to help! Please contact our customer support team for assistance: PHONE: LIVE CHAT: EMAIL: VIDEOS: SUPPORT HOURS: 856.234.8803 LuxProducts.com/support techsupport@luxproducts.com LuxProducts.com/Videos 8am to 6pm EST, Monday - Friday