Mastertrol Automatic Balancing System (MABS ) EZ Zone (EZ-2 and EZ-4) Control Panels

Similar documents
TZ-3 TotalZone Zone Control Panel

ZONE 2 MOTOR SW2 OPEN M6 M4 M2 M1 CLOSED ZONE 1 MOTOR SW1 OPEN M6 M4 M2 M1 CLOSED 24V T'FORMER 2 CB1 SYSTEM B GHC R CONTROLS INC.

TZ-4 TotalZone Zone Control Panel

Model CZ-4. Installation and Operating Instructions. FORM White-Rodgers by Permission B

Installation and Operating Instructions

CP-6 Installation and Operation Instructions 3 Heat / 2 Cool Heat Pump with Fossil Fuel option Auto Changeover - Cooling Priority or Majority Wins

Wiring: All wiring should be conventional 18 gauge thermostat wire. Thermostats and zone dampers may be located up to 300 feet from the Z-300 panel.

T6984F,G Electronic Floating Control Thermostats

RA889A Switching Relay

T7984 A,B,C Electronic Modulating Control Thermostats

CEPL WeatherMaker Two-Zone Installation and Start-Up Instructions

TB-226 ZONE 3 MOTOR M6 M4 M2 M1 ZONE 2 MOTOR M6 M4 M2 M1 MOTOR M6 M4 M2 M1 24 VAC T'FORMER SYSTEM W2/E W1/B O RH RC RC/RH LINK.

T6984 A,D,E Electronic Floating Control Thermostats

T8011R Programmable Heat Pump Thermostat

T8000C Programmable Thermostat

W8703A Damper Interface Module

T7200D,E Series 2000 Commercial Microelectronic Thermostats

T8524 Deluxe Electronic Thermostat

T8400C Universal Electronic Thermostats

HZ432 TrueZONE. Zone Panel Professional Installation Guide

T8602C Chronotherm IV Deluxe Programmable Thermostats

ZONE 3 MOTOR M6 M4 M2 M1 ZONE 2 MOTOR M6 M4 M2 M1 MOTOR M6 M4 M2 M1 24 VAC T'FORMER SYSTEM W2/E W1/B O RH RC RC/RH LINK.

T8112 Programmable Thermostat

Design & Installation for. Zonex Systems. System Zone Auto Changeover. System Zone Manual Changeover

T8600D Chronotherm IV Deluxe Programmable Thermostats

T7079A,B Solid State Remote Temperature Controllers

Premier 2-Zone Controller model Installer Guide

T8401C Electronic Thermostats

T8624D Chronotherm IV Deluxe Programmable Multistage Thermostats

T8611M Deluxe Programmable Heat Pump Thermostats

T7300F Series 2000 Commercial Microelectronic Conventional or Heat Pump Thermostat

Installation Instructions MODEL 8870

Deluxe Programmable Thermostats

Deluxe Programmable Heat Pump Thermostat T8611M

CR7075 Two-Stage Lighting Controller

F150E Media Air Cleaner

Installation Guide ProR221J, ProR212J, ProR321J and ProR312J

T7100D Microelectronic Conventional Thermostat

Product Instructions. Viega Programmable Heat/Cool Thermostat. Technical data

HEAT COOL HEAT PUMP. Installation Instructions TSTATCCNB001 TSTATBBNB001 P Digital Thermostat

NON-PROGRAMMABLE THERMOSTAT. The following Payne equipment is not compatible with the AC version (TSTATPPBAC01-B) of this

NON- INSTALLATION INSTRUCTIONS Venstar Inc. 08/07. Digital Thermostat T2700. commercial. & 2-cool. up to 2-heat PROGRAMMABLE

MAXIMUM UNIT AMPS MINIMUM WIRE SIZE

T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat

C554A Cadmium Sulfide Flame Detector

HEAT HEAT HEAT COOL COOL

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES

DIGITAL THERMOSTAT. I2:00 Su AUTO OPTIONAL HUMIDITY MODULE

asy Single Day up to 2-heat & 2-cool Stat

LZP-2 ZONE CONTROL PANEL

H1008A,D Automatic Humidity Controls

HEAT HEAT PUMP TOTALINE. Installation Instructions DIGITAL THERMOSTAT MODEL P FM. I2:00 Mo COOL

Y8150 Fresh Air Ventilation System, W8150 Fresh Air Ventilation Control

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

The T6140A,B Remote Bulb Temperature Controller

Y8150 Fresh Air Ventilation System, W8150 Fresh Air Ventilation Control

T834C Heating-Cooling Thermostat

INSTALLATION/OPERATING INSTRUCTIONS SEQUENCING PANELS

Y594 (Multistage Thermostat Subbase) Package

Z24 Wireless Zone Controller Professional Installation Guide

Install Guide 3M-10 ENGLISH

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

DIGI3U. Zoning Systems. Installation Guide. That s all we do. Three-Zone, Universal Controller for Gas/Electric or Heat Pump Applications

INSTALLATION INSTRUCTIONS FAN COIL PROGRAMMABLE DIGITAL THERMOSTAT. Meets California Title 24

Operator: Save these instructions for future use!

Emerson Blue Easy Set 1H/1C

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

ZONE PANEL KIT INSTALLATION MANUAL COMMUNICATING ZONE PANEL KIT - (S1-TCZCB01A) ZONE PANEL WITH ZONING TOUCH SCREEN FIRMWARE

Installation Instructions

INSTALLATION INSTRUCTIONS Venstar Inc. 08/07

INSTALLATION MANUAL. Need Help? This manual covers the following models: T905. Power Type. Thermostat Applications Guide. Page.

Installation Instructions

Installation and Operating Instructions

CT500 Electronic Thermostat

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

Installer : Save these instructions for future use!

T8400C and T8401C Electronic Thermostats

Zoning System Design Manual

H32 Uni- Zone Model H32

TP-S-855i MENU AUTO HEAT. Installation Tips. Installation Manual. Installation Tips. Installation Tips. Hardwire - 24 VAC Common Wire

Installation Instruction

INSTALLATION MANUAL. Need Help? This manual covers the following models: T705. Power Type. Thermostat Applications Guide. Page.

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

T8011F Flush Mount Programmable Heat PumpThermostat OWNER S GUIDE

M6063A Compact Rotary Mixing Valve Actuator

INSTALLATION MANUAL. Need Help? This manual covers the following models: T805. Power Type. Thermostat Applications Guide. Page.

L Honeywell. L4068 has spst switch; L6068 has spdt switch. L4068A,C,E,F have adjustable FAN OFF and differential settings.

C6097A,B Pressure Switches

T8195B/Q682B,C, Y8224A Heating or Cooling and Heating/Cooling New Construction Thermostat, Wallplate and Subbase

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFH24F3XYZ2 Stand-alone with Internal Humidity Sensor

Standard Programmable Thermostat Homeowner s Guide / Installation, Start-Up, and Operating Instructions

Operator: Save these instructions for future use!

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

F200E Charged-Media Air Cleaner

Thermidistat Control Installation, Start-Up, and Operating Instructions

T8411R Electronic Heat Pump Thermostat

45 Commerce Ave., Unit #2 South Burlington, VT tel: fax:

VisionPRO 8000 with Wi-Fi

Transcription:

Mastertrol Automatic Balancing System (MABS ) Z Zone (Z-2 and Z-4) ontrol Panels FATUS PDUT DATA APPLIATIN The MABS Z-2 and Z-4 are microprocessor-based forced air zone control panels that provide automatic or manual changeover control of single- and two-stage heating and cooling and heat pumps with or without auxiliary heat. MABS Z-2 controls two zones and MABS Z-4 control four zones. For systems requiring five or more zones, the TotalZone series of control panels is used. Uses standard four-wire (,W,Y,) thermostats. Any zone thermostat changeover is based on first call. Bank of eight DIP switches provides easy system configuration. Adjustable purge timing of two minutes or three and one-half minutes. Adjustable heating and cooling limit with optional ZoneMAX Sensor. Stage control allows built-in timer to control heating and cooling stages. Use any four-wire thermostat. For Internet access: www.trolatemp.com or www.honeywell.com/yourhome/zoning/zoning_home.htm For technical support, call 1-800-TAT-Temp (1-800-828-8367). To download Zoning literature: http://hbctechlit.honeywell.com ontents Application... 1 Features... 1 Specifications... 2 rdering Information... 2 Installation... 3 Startup and heckout... 8 peration... 9 Troubleshooting... 12 U.S. egistered Trademark opyright 2001 Honeywell All ights eserved 69-1360- 2

MASTTL AUTMATI BALANIN SYSTM (MABS ) Z ZN (Z-2 AND Z-4) NTL PANLS SPIFIATINS lectrical: 24 Vac, 60 Hz. Dimensions: 9-3/8 in. high x 7-5/8 in. wide x 1-5/8 in. deep. Mounting: Mount with screws (supplied) through holes in cabinet back. Wiring: 18-gauge wire for all equipment and system connections Wiring onnections: Thermostat: L,, Y,, W. Dampers: M6 (losed); M4 (pen); M1 (ommon) Zone- MAX TL, TL Transformer: T1 (ommon), T2 (Hot) quipment:,,,,, B,,, Thermostats (See Table 1): onventional four-wire (,W,Y,) thermostats. Manual or automatic changeover switching subbase for each zone thermostat. MABS Z second-stage timer and emergency heat switch replace multi-stage or heat pump thermostat. MABS Z with heat pump thermostat controls mergency Heat mode from thermostat and MABS Z panel switch. equires separate and outputs for the heat and cool calls. equires L terminal energized when mergency Heat switch is on. thermostat terminal is not used. MABS Z panel timer turns on auxiliary heat when not in mergency Heat mode. Table 1. ecommended Thermostats. Trol-A-Temp Logo Honeywell Logo System Mechanical Programmable Non-Programmable Programmable Manual hangeover T87F3715/Q539A1436 T87F3707/Q539A1428 T81311020 T87F1859/Q539A1014 Q87F4010/Q539A4026 T8400 T80001002 T80001010 Auto hangeover Heat Pump T8601D2027 Y594D1347 T8600D2069 T8600D2028 T8601D2019 T8602D2018 T8602D2000 T80111006 T80111014 T84111002 T84111028 DIN INFMATIN When purchasing replacement and modernization products from your TADLIN wholesaler or distributor, refer to the TADLIN atalog or price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Home and Building ontrol Sales ffice (check white pages of your phone directory). 2. Home and Building ontrol ustomer elations Honeywell, 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 In anada Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, ntario M1V4Z9. International Sales and Service ffices in all principal cities of the world. Manufacturing in Australia, anada, Finland, France, ermany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 69-1360 2 2

MASTTL AUTMATI BALANIN SYSTM (MABS ) Z ZN (Z-2 AND Z-4) NTL PANLS Dampers: See Fig. 3-7 for hookup drawings. See Table 2 for recommended dampers. Accessories: For required accessories, see Table 3. Table 2. ecommended Dampers. Honeywell Damper Types ound ectangular Power-open/ power-closed Spring-open/ power-closed MAD AD ABD ABD-BM D-51 ZDB ZDS Table 3. equired Accessories (Not Supplied With Panel). Accessory Description Bypass ated apacity (cfm) 40 VA Transformer AT140D1046 (PMT-40) _ apacity Protector ZMS/7735 _ ound Static Pressure egulator Damper (SPD) ectangular Static Pressure egulator Damper (SPD) 7 SPD 8 SPD 9 SPD 10 SPD 12 SPD 14 SPD 16 SPD 18 SPD 12 x 8 SPD 12 x 10 SPD 12 x 12 SPD 20 x 8 SPD 20 x 10 SPD 20 x 12 SPD 300 400 600 750 1200 1800 2400 3200 1000 1200 1400 1600 2000 3000 INSTALLATIN Mounting AUTIN quipment Damage Hazard. Do not mount MABS Z inside HVA equipment. Mount only on wall or on cold air return 1. Mount the thermostats in each zone of the living space using the installation instructions provided with each thermostat. 2. Mount the dampers in the ductwork using the installation instructions provided with each damper. 3. Mount the MABS Z Zone Panel near the HVA equipment; locate it on a wall or on the cold-air return. 4. Level the MABS Z for appearance only. Wiring AUTIN Voltage Hazard. an cause electrical shock or equipment damage. Disconnect power before continuing installation. Wiring must comply with applicable codes, ordinances, and regulations. 1. onnect thermostats as shown in Fig. 1 and 2. 2. onnect dampers as shown in Fig. 3-7. 3. onnect the ZMS (not supplied) to the TL terminals.the wires are not polarized. See Fig. 9. 4. onnect the HVA equipment to the equipment terminals on the left side of the panel. See Figures 10-13. 5. onnect a 40 VA, 24 volt transformer (not supplied) to T1 (common) and T2 (hot). This must be a dedicated transformer. See Fig. 8. 3 69-1360 2

MASTTL AUTMATI BALANIN SYSTM (MABS ) Z ZN (Z-2 AND Z-4) NTL PANLS Wiring Diagrams See Table 1 for recommended thermostats. See Fig. 1-15 for wiring appropriate wiring diagrams. Wiring is the same for ABD, ABD-BM and IBD Dampers. The common wire ( to M1) is used only on thermostats that require it. MT TMINALS M6 M4 M1 ZN NNTINS N PANL THMSTAT MT L Y W M6 M4 M1 4 5 6 1 2 3 4 5 6 1 2 3 FILD JUMP DAMP MTS M19036 Y W ZN THMSTAT M19033 Fig. 1. Typical single-stage thermostat hookup diagram. Fig. 4. ABD Damper wiring (multiple). For three or more ABD dampers on one zone, a Slave Damper ontrol elay (SD) is required. ZN NNTINS N PANL THMSTAT MT L Y W M6 M4 M1 DAMP TMINALS N PANL M6 M4 M1 L /X PW LS SPIN PN MDL AD, ZDS, ZDB M19037 ZN THMSTAT M19034 Fig. 5. AD or ZD Damper wiring diagram. Fig. 2. Heat pump thermostats with separate heat and cool outputs. Use only thermostats listed in Table 1. MT TMINALS M6 M4 M1 Multiple dampers can be wired in parallel, with up to five dampers wired to each panel. DAMP TMINALS N PANL M6 M4 M1 M/M1 L/M6 4 5 6 1 2 3 P/M4 M19038 FILD JUMP Fig. 6. MAD and D-51 Damper wiring diagram. DAMP MT M19035 Fig. 3. ABD damper wiring (single). 69-1360 2 4

MASTTL AUTMATI BALANIN SYSTM (MABS ) Z ZN (Z-2 AND Z-4) NTL PANLS 2 1 Fig. 7. ML6161 Damper Motor Actuator wiring diagram. NTL PANL NNTINS 8222 24V SPDT LAY ML6161A MT The 8222 relay is not required for operation, but if it is not used, the zone damper LD will be constantly green. T2 T1 M6 M4 M1 W M W M19039 UTD NDNSIN UNIT MPSS LAY 24V TANSFM FAN LAY HAT LAY HVA NTLS B M19042 Fig. 10. Single-stage heating and cooling equipment wiring diagram. NTS: lectric Furnace: Set DIP switch 8 to n to energize the fan with a call for heat. il Furnace: See Fig. 11 for hookup. Hydro-Air: Wired similarly except the zone valve or circulator relay is connected to the. (If the circulator relay has powered terminals, an isolation relay may be needed. See Fig. 11.) DIP switch 8 must be set to n to energize the fan with a call for heat. Y W MABS Z PANL 24V, 40 VA TANSFM MDL PMT-40 HVA NTLS MABS Z PANL M19040 Fig. 8. Transformer wiring diagram. A dedicated 40 VA, 24 Vac transformer must be used. LIN LAY 24V TANSFM FAN LAY B ZMS SNS or 7735 TL TL M19041A IL PIMAY T 8222 24V ISLATIN LAY Fig. 9. ZoneMAX or 7735 Sensor wiring diagram. T M19043 Fig. 11. il furnace and air conditioning wiring diagram. The isolation relay is required to isolate the cooling transformer from the heating transformer. 5 69-1360 2

MASTTL AUTMATI BALANIN SYSTM (MABS ) Z ZN (Z-2 AND Z-4) NTL PANLS Fig. 12. Two-stage heating and cooling wiring diagram. HVA NTLS SND STA LIN LAY FIST STA LIN LAY 24V TANSFM FAN LAY FIST STA HATIN LAY SND STA HATIN LAY MABS Z PANL B M19044 The stage timer energizes the second stage equipment. UTD NDNSIN UNIT MPSS LAY MPSS LAY VSIN VALV 24V TANSFM FAN LAY FIST STA HATIN LAY SND STA HATIN LAY HAT PUMP NTLS Y MABS Z PANL B DIP SWITH NFIUATIN N. 8 - N 2 STA M. HT. M19045A Fig. 13. Heat pump wiring diagram. IMPTANT must be jumped to for compressor control. Set DIP switch 8 to n to energize the fan with a call for heat. NTS: Fossil Fuel Kits with Heat Pumps: The wiring for these heat pumps is similar but the manufacturer's fossil fuel control must be used. The Z equipment terminals are wired using the thermostat terminals shown on the heat pump manufacturer's wiring diagrams. Two-speed ompressors: For two-speed compressors or two-speed compressors with auxiliary heat, the MM-3U or TotalZone panels are recommended. all Honeywell Zoning at 800-828- 8367 for assistance. 69-1360 2 6

MASTTL AUTMATI BALANIN SYSTM (MABS ) Z ZN (Z-2 AND Z-4) NTL PANLS TM PTINAL ZoneMAX 7735 SUPPLY AI TMPATU SNS HVA NTLS SND STA LIN LAY FIST STA LIN LAY TM ZoneMAX TL TL HAT L PU FAN M.HT ZN 1 ZN 2 BT Z2 V. F N N - DAMP PN/MVIN FF - DAMP LSD 1 2 3 4 5 6 7 8 M HAT N FF VSIN VALV (LIN) 24V TANSFM (HT) FAN LAY VSIN VALV (HATIN) FIST STA HATIN MNY HAT LAY SND STA HATIN LAY B PU VID FIH L Y W M6 M4M1 L Y W M6 M4 M1 T1 T2 THIS DIAAM SHWS TYPIAL SINL-STA THMSTAT AND DAMP MT NNTINS. 2ND ST. M. THMSTAT ZN 1 MT THMSTAT ZN 2 MT ZN THMSTAT Y W ZN 1 THMSTAT Y W ZN 2 THMSTAT ZN DAMPS 4 5 6 7 1 2 3 X 24V, 40 VA TANSFM PPSD BLAD DAMPMT AUTMATI UND DAMP PW LSD (AD-P) M19046A Fig. 14. MABS Z-2 wiring diagram. 7 69-1360 2

MASTTL AUTMATI BALANIN SYSTM (MABS ) Z ZN (Z-2 AND Z-4) NTL PANLS HAT L PU FAN M.HT ZN 1 ZN 2 ZN 3 ZN 4 TM PTINAL ZoneMAX 7735 SUPPLY AI TMPATU SNS HVA NTLS SND STA LIN LAY FIST STA LIN LAY ZoneMAX TM TL TL BT N 1 2 3 4 5 6 7 8 N - DAMP PN/MVIN FF - DAMP LSD M HAT N FF VSIN VALV (LIN) 24V TANSFM (HT) FAN LAY VSIN VALV (HATIN) FIST STA HATIN MNY HAT LAY SND STA HATIN LAY B PU VID T2 T1 2ND ST. M. L Y W M6 M4M1 L Y W M6 M4 M1 L Y W M6 M4M1 L Y W M6 M4 M1 THMSTAT MT THMSTAT MT THMSTAT MT THMSTAT MT THIS DIAAM SHWS TYPIAL SINL-STA THMSTAT AND DAMP MT NNTINS. ZN 1 ZN 2 ZN 1 ZN 2 ZN THMSTAT Y W ZN 1 THMSTAT Y W ZN 2 THMSTAT Y W ZN 3 THMSTAT Y W ZN 4 THMSTAT 24V, 40 VA TANSFM 4 5 6 7 4 5 6 7 ZN DAMPS 1 2 3 X 1 2 3 X PPSD BLAD DAMPMT AUTMATI UND DAMP PW LSD (AD) PPSD BLAD DAMPMT AUTMATI UND DAMP PW LSD (AD) M19047A Fig. 15. MABS Z-4 wiring diagram. STATUP AND HKUT After the installation is complete, verify the operation: 1. Put the m Heat switch in the off (down) position. 2. Be sure the DIP switches are set correctly. See Sequence of peration and Table 6 for correct configuration. The default position is in the off (down) position. 3. Power up the MABS Z and set the thermostats so no zones are calling. Verify that the board? enters the Purge mode. During the two- or three and one-half- minute Purge, the Purge LD should be amber. During this mode, the dampers are open and the damper LDs are lighted green. 4. Set the zone one thermostat to heat and raise the setpoint to call for heat. The Heat LD is red and the zone one damper remains green while the other damper LDs turn off. 5. Lower the setpoint in zone one and raise the setpoint in zone two to call for heat. Verify that zone one LD turns off (also zones three and four turn off when used on MABS Z-4) and zone two damper is green. 6. When using a MABS Z-4, repeat for zones three and four and verify correct operation. 7. Alternately, the setpoint can be lowered to call for cooling. Then the green cool LD lights. 69-1360 2 8

MASTTL AUTMATI BALANIN SYSTM (MABS ) Z ZN (Z-2 AND Z-4) NTL PANLS PATIN Sequence of peration n a call for heating or cooling, the zone damper to the calling zone stays open, and the dampers close to the zones that are not calling. The MABS Z panel brings on the heating or cooling and conditioned air is delivered to the calling zone until the zone is satisfied. When the call is satisfied, the system enters the Purge mode. This holds open the damper of the last zone calling and purges into that zone. The Purge time can be set to three and one-half or two minutes. Individual Zone Fan ontrol When all zones are satisfied, each zone thermostat Fan switch controls the fan operation for each zone. When circulation is desired, place the Fan switch in the n position. The fan runs and closes the dampers to the zones where the Fan switch is set to Auto. Multi-Stage peration MABS-Z can control up to two stages of heating and cooling using singe-stage thermostats. The panel uses a timer to control the second stage and is adjustable from five minutes to 30 minutes using DIP switches 5, 6, and 7. See Table 4. When a call for heating or cooling is not satisfied within the time set on the stage time, the panel energizes the second stage of heat or cool and both stages remain on until the call is satisfied. Table 4. Stage timer configuration. Minutes DIP Switch 5 DIP Switch 6 DIP Switch 7 5 ff ff ff 8 n ff ff 10 ff n ff Table 4. Stage timer configuration. Minutes DIP Switch 5 DIP Switch 6 DIP Switch 7 12 n n ff 15 ff ff n 20 n ff n 25 ff n n 30 n n n hangeover peration The MABS Z panel uses a standard heating and cooling thermostat for each zone to allow any zone to call for heating or cooling. When opposite calls are made from different zones, MABS Z accepts the first call. nce the first call is satisfied, or a maximum of 20 minutes elapses from the start of an opposite call, MABS Z allows the opposite call. Automatic changeover thermostats can also be used to provide automatic zone changeover. When opposite calls occur, the panel ensures that both calls are acknowledged. If the first call is not satisfied within 20 minutes, the panel drops the existing call and goes into the Purge mode. After completion of the Purge, the panel switches to the opposite mode until it is satisfied or until 20 minutes elapses.then it goes back into the Purge mode and back to the original call. The system continues to switch back and forth until both calls are satisfied. Purge Mode At the end of every call for heat or cool, the panel enters a Purge mode that holds the last zone damper open for three and one-half or two minutes. During this time, the panel or HVA equipment can operate the fan. Purge is a time delay that prevents short cycling of the heating and cooling equipment after each call. The Purge LD lights when the system is in Purge mode. Press Purge verride button when the purge LD is lighted to override Purge. 9 69-1360 2

MASTTL AUTMATI BALANIN SYSTM (MABS ) Z ZN (Z-2 AND Z-4) NTL PANLS ZoneMAX Sensor Leaving Air Temperature Sensor Table 5. Purge DIP switch settings. DIP Switch No. Setting Action 1 ff 3.5 minutes 1 n 2 minutes 2 ff Panel control of fan in Purge 2 n HVA control of fan in Purge LD Indicators The panel features several LD status indicators visible through a window in the cover. See Table 6. The ZMS (not included) is a duct-mounted temperature probe that monitors the supply of air temperature to control capacity and prevent over-heating or coil icing. The sensor attaches to the TL terminals at the upper left corner of the panel. See Fig. 9. IMPTANT The ZMS wires must be at least 12 in. away from line voltage wiring to ensure correct operation. When not possible, shielded cable must be used. ZoneMAX Sensor onfiguration DIP switches 2 and 3 set the ZoneMAX Sensor temperature limit. See Table 7. The recommended setting for fossil fuel/ heat pump systems is 160 F (71 ). For heat pump systems, the recommended setting is 120 F (49 ). The cooling temperature limit can be set to 40 F (4 ) or 48 F (9 ). Table 6. LD Status Indicators. Table 7. ZoneMAX Sensor onfiguration. LD olor Lighted Status Not Lighted Heat ed Heat call Not in heat call ool reen ool call Not in cool call Purge Amber Purge mode Not in Purge mode Flashing ZMS high temperature limit tripped ZMS low temperature limit tripped _ DIP Switch No. ff (Default) 2 ZMS 160 F (71 ) heating limit 3 ZMS 40 F (4 ) cooling limit Setting n ZMS 120 F (49 ) heating limit ZMS 48 F (9 ) cooling limit PATIN If the system trips due to exceeding a high or low temperature, the heating or cooling system shuts down and the fan continues running to dissipate the conditioned air from the plenum. If the low limit was tripped, the cool LD flashes continuously until it resets. If the high limit was tripped, the Heat LD flashes continuously until it resets. Fan reen Fan only call m Heat Zone 1,2, 3,4 ed reen mergency heat switch on or thermostat in emergency heat Damper open or moving No fan only calls Not in emergency heat mode Damper closed e-booting the Microprocessor When conditions hang up the microprocessor, press and release the Boot button to re-boot the system and enter the Purge mode. _ The ZoneMAX Sensor resets and allows normal system operation when the supply air temperature rises ten degrees in cooling mode, or falls ten degrees in heating mode. The ten degrees provide adequate time to prevent short cycling of the unit. ircuit Breaker Protection A built-in thermal circuit breaker protects the panel against shorts in the thermostat and damper wiring and the remote occupied/unoccupied switch. It does not protect against shorts in the HVA equipment wiring into the panel. PATIN None of the LDs light when the circuit breaker tripped. The fuse is a yellow square or rectangular disk located right of the T1 and T2 terminals. If it is hot to touch, remove panel power for ten seconds to allow the circuit breaker to cool off and reset. 69-1360 2 10

MASTTL AUTMATI BALANIN SYSTM (MABS ) Z ZN (Z-2 AND Z-4) NTL PANLS Thermostats The panel can use almost any four-wire (,W,Y,) thermostat. ach zone requires its own switching subbase with either manual or automatic changeover. See Table 1 for recommended thermostats. HAT PUMP MULTI-STA THMSTATS Heat pump or multi-stage thermostats are not required for the MABS Z panels because a timer in the panel brings on the second stage. A heat pump thermostat is used only when emergency heat control from the thermostat is desired. Use only Table 1 recommended heat pump thermostats. MNY HAT MD An emergency heat switch is located on the side of the panel and can be accessed without removing the cover. A heat pump thermostat is used only when emergency heat control is desired from the thermostat instead of from the panel. nergizing the L terminal on the zone thermostat or switching the mergency Heat switch to the n position places the system in mergency Heat mode. This switch does not initiate a call for emergency heat and prevents the first stage (heat pump) from being used on a call for heat. Fan n In Heat The system fan can be set to come on with a heat call, as required, with a hydro-air, heat pump, or electric heat system. Set DIP switch 8 to the n position to activate this mode. therwise, leave it in the default ff position. Second Stage mergency Heat Jumper A jumper is installed on the jumper block to energize output during a call for emergency heat. If there are two forms of auxiliary heat, one can be connected to as the second stage of heat and the other to as the emergency heat stage. See Fig. 4. DIP Switch N. Table 8. DIP Switch Settings. Switch Function with DIP Switch ff (Default) 1 3.5 minute Purge with fan on 2 ZMS 160 F (71 ) heating limit 3 ZMS 40 F (4 ) cooling limit Switch Function with DIP Switch n 2 minute Purge with fan off ZMS 120 F (49 ) heating limit ZMS 48 F (9 ) cooling limit 4 Normal operation Test mode; accelerated timings 5 See Table 4. _. 6 See Table 4. _ 7 See Table 4. _ 8 HVA unitcontrolled fan Fan on with call for Heat 11 69-1360 2

MASTTL AUTMATI BALANIN SYSTM (MABS ) Z ZN (Z-2 AND Z-4) NTL PANLS TUBLSHTIN The primary diagnostic tools are the system and damper status LDs. See Table 9 for troubleshooting guide. Table 9. Troubleshooting uide. Symptom Problem Solution No LDs light No power to the panel. heck for 24 Vac across T2. heck circuit breaker; if hot, a short exists in thermostat or damper wiring. rratic operation Heat or ool Ld flashes continuously Heat pump works in Heat but not in ool or in ool but not in Heat mergency heat not coming on Insufficient voltage. Incorrect configuration Panel in mergency Heat mode Panel needs resetting. Heat LD flashing. ool LD flashing. Incorrect thermostat. Incorrectly wired. Incorrectly wired. Incorrect thermostat. heck for 24 Vac ±10% across T1 and T2. Verify jumpers and DIP switch setting for correct configuration. heck position of m Heat switch. Press Boot button and recheck system operation. ZoneMAX Sensor tripped on high limit. ZoneMAX Sensor tripped on high limit. Install the correct thermostat. If equipment is heat pump, be sure there is a or jumper installed. Verify thermostat and equipment wiring. Verify correct thermostat is used. Printed in U.S.A. on recycled 69-1360 2.H. ev. 9-01 paper containing at least 10% www.honeywell.com/yourhome post-consumer paper fibers.