Laboratory Open Scroll Air Compressor System with Premium NFPA Controls

Similar documents
Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14

Scroll Medical Air Compressor with Premium NFPA Control Panel

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Enclosed Scroll Air Compressor System SES 3-5 HP

Laboratory Enclosed Rotary Screw Air Compressor System with Air Treatment Center Package

Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12

Technology for the Better Future. Medical Air Compressor Systems

Medical Vacuum Systems Product Selection Guide

5 20 HP OIL-LESS ROTARY SCROLL COMPRESSOR. EnviroAire ES

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

SECTION COMPRESSED-AIR EQUIPMENT FOR LABORATORY FACILITIES

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

3 10 HP OIL-LESS ROTARY SCROLL COMPRESSOR. EnviroAire Series

Desiccant Air Dryers. ABP Series. Blower Purge Desiccant Air Dryer 70-8,000 scfm

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

SECTION AIR COMPRESSORS AND ACCESSORIES

Reciprocating Instrument Air System. Installation Operation and Maintenance Manual 5-20 Hp

Dual Tower Heat Reactivated Desiccant Air Dryer

Specifications. General Safety Information. NOTE: Information that requires special attention.

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration

Description. Specifications. Safety Guidelines. Unpacking. General Safety Information

Technical Specification

REFRIGERATED AIR DRYERS

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

SECTION AIR COMPRESSORS AND ACCESSORIES

SULLAIR DESICCANT DRYERS

Compressed Air Dryers

Heatless Desiccant Compressed Air Dryers

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr)

Single Tower Heat Reactivated Desiccant Air Dryer

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Enclosed Scroll Laboratory Air Systems

Desiccant Drying DRYPOINT XC. efficient low dew point heatless desiccant drying. Truth in Compressed Air.

Desiccant Dryers. Desiccant Dryers. Heatless Heated Purge Blower Purge Modular

Quality Components as a basis for Quality Equipment

MR Series Heatless Mini Regenerative Desiccant Dryer. Operator s Manual

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL

Title: 999 Campus Air Compressor FY 17 Bid Specs

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products


Refrigerated Air Dryers

100% Oil-Free - Guaranteed

Scroll Medical & Laboratory Compressed Air Systems

Operation and Maintenance Manual. Dryer Package. Model Number: Job Number: Date Shipped: Date Started Up: Electrical: 120 V single phase - AC

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

Title: 999 Campus Air Compressor FY 17 Bid Specs

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

SSB Blower Purge Desiccant Dryers SSE Heat Reactivated Desiccant Dryers 220 to 10,500 scfm

Heatless Regenerative Compressed Air Dryers. Compressed Air System Products. Made in America

REFRIGERATED AIR DRYERS

Desiccant Regenerative Dryers 3-10,000 scfm

Heatless Air Dryers AIRTEK PREMIUM PRODUCTS FOR INDUSTRY. TW Series

Desiccant Air Dryers. Heatless, Heated and Heated Blower

HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products

TWP & TWB Series Externally Heated and Blower Purge Desiccant Air Dryers

Atlas Copco Stationary Air Compressors. GA30-90C WorkPlace Air System TM 30-90kW/40-125HP oil-injected rotary screw compressors

HEATLESS REGENERATIVE DRYERS

DGH Series Global Air Treatment

Pressure Swing Desiccant Dryers

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

MDH Series Air Dryer. User s Guide

VSA Series Air Dryer. User s Guide

Titus Air Systems. TDD Series. The need for clean and dry compressed air. Energy efficiency

TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION

Externally Heated Desiccant Air Dryer RP Series

Oil-Free Compressors. Oil-Free Compressors. Quincy QOF Series Oil-Free Air Compressors QOF 2-30 HP

Screw Compressors. S Series. Capacities from: 8.8 to 89 cfm Pressures from: 80 to 217 psig.

Compressed Air Specialists

DESICCANT AIR DRYERS. BD + CD + CD series

AirCel. Heated Regenerative Desiccant Dryers. AEHD Externally Heated, HRE Blower Purge, and HRS-L Zero Purge Series

QUINCY QOF SERIES OIL-FREE AIR COMPRESSORS QOF 2-30 HP

Downstream Equipment. Intelligent Air Technology

The Quincy QMB and QMT: A new approach to the modular advantage

Waveguide Dehydrators

CDT Series MCGUIRE AIR COMPRESSORS INC MCGUIRE AIR COMPRESSORS INC Heatless Desiccant Air Dryers 40 5,400 SCfm

Meeting Your Compressed Air Treatment Needs

Atlas Copco. Heat-of-compression rotary drum dryers ND series ( l/s, cfm)

RTi Compressor Guide. Screw - Horizontal. Piston - Vertical Duplex - Horizontal. Screw - Vertical. Piston - Cube. Screw - Enclosed Elite.

Desiccant Air Drying Technologies HCS Series HCL Series HCT Series

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

QUINCY QGS SERIES hp

QUINCY QPNC SERIES NON-CYCLING QUINCY QRHT SERIES HIGH TEMP

EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252

Lubricated Rotary Screw Air Compressors

Rotary Screw Compressors SM Series

Mission Critical. Fuel Supply Systems

QGB QUINCY QGB SERIES ROTARY SCREW AIR COMPRESSORS HP

Externally Heated Exhaust Purge Regenerative Compressed Air Dryer

UA Series Air Dryers. 10 Year Warranty Limited ( SCFM) Setting a new standard in Quality and Reliability WAS 360

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

Oil Free Scroll Compressors

HEATLESS REGENERATIVE COMPRESSED AIR DRYER models THL-200 through THL- 5000

Modular Adsorption Dryers

HEATLESS DESICCANT AIR DRYERS

CPBg hp CPVSd hp. People. Passion. Performance.

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 5-11 (5,5-11 kw/7,5-15 hp)

next generation R 1 cycling refrigerated compressed air dryers flow capacity: scfm ( Nm 3 /hr)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 5-11 (5,5-11 kw/7,5-15 hp)

Transcription:

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Specification General The Powerex Laboratory Open Scroll Air Compressor System is designed to provide clean, dry air for applications where the quality of the compressed air is critical. The standard unit is rated for a maximum of 145 PSIG. Each system is completely tested before shipment and includes: Multiple oil-less scroll air compressors and associated equipment. Corrosion resistant air receiver. Desiccant air dryers with purge control. Control panel. Dew point monitor. The only field connections required will be system intake, exhaust, and power connection at the control panel. All interconnecting piping, wiring, and vibration isolation pads are included with the system. Open Scroll Air Compressor System The package shall include multiple oil-less scroll air compressors and associated equipment. The only field connections required will be system intake if remote intake option is chosen, exhaust, and power connection at the control panel. Oilless Scroll Compressor Pump Each compressor shall be belt driven oilless rotary scroll single stage, air-cooled construction with absolutely no oil needed for operation. Direct drive compressors shall not be used. The rotary design shall not require any inlet or exhaust valves and shall be rated for 100% continuous duty. Tip seals shall be of a composite PTFE material and be rated for 5,000 hours operation. Compressor bearings shall be external to the air compression chamber and shall all be serviceable for extended compressor life. Bearing maintenance shall not be required until 5,000 run hours. Compressors with bearings that are not accessible for service have a limited life span and shall not be accepted. Compressors shall have an integral radial flow fan for cooling and shall not require any additional electric cooling fans. Each compressor shall have flexible connectors on intake and discharge, an electric drive motor, a discharge check valve, an air-cooled aftercooler, a condensate separator* and a high discharge temperature shut down switch. Each compressor module shall have an isolation valve and a moisture separator* with automatic drain. Motor Each compressor shall be belt driven by a 1750 RPM, ODP, NEMA construction motor. Motors running at speeds higher than 1750 RPM shall not be acceptable. OSHA approved belt guards shall be provided. Air Receiver The system shall include an ASME air receiver rated for 200 PSI MAWP. The tank shall be equipped with: A pressure gauge and a safety relief valve. By-pass valves to allow tank isolation without system shutdown. A sight gauge. An automatic electronic tank drain with manual override. The receiver shall be internally lined with an FDA approved material for corrosion resistance. Premium NFPA Control Panel The control system provides automatic lead/lag sequencing and automatic alternation of all compressors in order to equalize the amount of usage among the available compressors. The Premium NFPA Control Panel shall include a gateway server card and all features listed below: Building automation communication gateway with BacNet protocol and Web server features. Web server features include email notifications in case the system is in alarm or has achieved one of its maintenance intervals and requires service. Ethernet port for connection to BacNet server or direct connection to facility Ethernet for viewing of system operations and status via device IP-address. UL508-A listed control panel in a NEMA 4/12 enclosure. The panel door will include: 6 Color touch-screen HOA (hand-off-auto) switch for each pump 3-position Dryer control switch (dryer1-bothdryer2) 95 dba alarm horn Acknowledge push-button (to silence the horn) The 6-inch color touch-screen will display: Pump status: On, Off, or Ready Pump Faults/Service state: High temperature, overload trip, service required Pump run hours System pressure System Dew-point Trends Pump information screens will display pump maint intervals with required service System alarm screen: Low Pressure Alarm General Fault Alarm (Pump faults) Air Quality Alarm (Dew-point or optional CO) Pump Maint required Dryer and monitor service notices Alarm log Dry contacts are provided on a labeled terminal strip for remote monitoring of all system alarms. P 1.888.769.7979 F 513.367.3125 www.powerexinc.com 01/2017 Page 1 of 2

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Air Purification Package The air purification package shall consist of the following: dual desiccant air dryers, dual filter and regulator bank with sample ports, and dew point monitor with alarms, and all bypass piping. Piping to be brass, stainless, or type K copper, and cleaned for medical air use. All components shall be mounted piped and wired to the air receiver. Desiccant Air Dryers The twin-tower, heatless desiccant air dryer is designed for a pressure dew point of -40 degrees F. Each dryer is sized to meet the full SCFM requirement of the system. The dryer shall be installed and plumbed on a common steel skid to the air receiver. The dryer design shall be of the automatic pressure swing, heatless, regenerative type and shall include a solid state cycle timer, reliable switching valve design, and purge muffler for quiet operation. Dryer controls shall include on/off/variable mode selector switch, and digital display. The filtration system shall consist of 2 stages of filtration mounted and plumbed to the air dryer. The first stage of filtration shall include a centrifugal water separation and a 5 micron filter element with element coalescing vibration or a.01 micron or finer pre-filter with element change indicator and automatic condensate drain and installed upstream of the air dryer. The second stage shall include a 1 micron (or finer) particulate filter with element change indicator and installed downstream of the air dryer. Filtration and Pressure Reducing Station Each filter/dryer/regulator assembly shall be plumbed with bypass valves to enable service without disrupting air flow to the facility. Each assembly also includes a sample air port. The filtration systems consist of two stages of filtration as outlined above in the Desiccant Air Dryers section. Additionally, each assembly shall include a dual set of pressure reducing valves with pressure gauges shall be installed downstream of the final filters and shall be adjusted to an outlet pressure of 115 psig. P 1.888.769.7979 F 513.367.3125 www.powerexinc.com 01/2017 Page 2 of 2

Laboratory Open Scroll Duplex with Premium Controls Model Dim. A Dim. B Dim. C Optional Outlet LSD0203 32 74 62 ¾ ½ LSD0303 32 74 62 ¾ ½ LSD0503 32 78 71 ¾ ¾ LSD1004 32 78 71 1 ½ 1 C A Laboratory Air Duplex Package with Premium Controls SCFM @ 145 Tank Size PSIG (1,2) BTU/Hr db(a) System F.L.A. System Level (1) 208V 230V 460V Weight (lbs) LSD0203 2 (2) 9.2 80 9,740 70 13.9 12.8 7.4 1,300 LSD0303 3 (2) 14.2 80 14,600 75 19.1 17.4 9.7 1,450 LSD0503 5 (2) 25 80 24,400 75 30 27.4 14.7 1,500 LSD1004 10 (2) 50 120 48,800 77 58 52.8 27.3 1,900 1 SCFM, BTU/Hr, and db(a) values listed are with all pumps running. 2 Powerex recommends using performance ratings in SCFM when sizing laboratory air systems. 3 Remote inlet optional (not shown). Standard inlet is ambient intake filter assembly at each pump. 4 3 Year Limited Warranty. B 9/2016

Laboratory Enclosed Scroll Triplex with Premium Controls Model Dim. A Dim. B Dim. C Optional Outlet LST0504 32 83 77 1 1 LST1005 66 94 83 2 1 ½ Laboratory Enclosed Scroll Triplex with Premium Controls SCFM @ Tank Size 145 PSIG (1,2) BTU/Hr db(a) System F.L.A. System Weight Level (1) 208V 230V 460V (lbs) LST0504 5 (3) 37.5 120 36,600 76 44 40.1 21 1,850 LST1005 10 (3) 75 200 73,200 78 86 78.2 40 2,900 1 SCFM, BTU/Hr, and db(a) levels are shown with all pumps running. 2 Powerex recommends using performance ratings in SCFM (Standard Cubic Feet per Minute) when sizing laboratory air systems 4 Remote inlet option not shown. Standard inlet is ambient intake filter assembly at each pump. 5 3 Year Limited Warranty 01/2017

Laboratory Open Scroll Quadplex with Premium Controls Model Dim. A Dim. B Dim. C Optional Outlet LSQ0504 32 78 78 1 ½ 1 Laboratory Open Scroll Quadplex with Premium Controls SCFM @ 145 Tank Size psig (1) BTU/Hr db(a) System F.L.A. (1) System Level (1) 208V 230V 460V Weight (lbs) LSQ0504 5 (4) 50 120 48,800 77 58 52.8 27.3 1,900 1 SCFM values, BTU/Hr levels, and db(a) are shown with all pumps running. 2 Powerex recommends using performance ratings in SCFM (Standard Cubic Feet per Minute) when sizing laboratory air systems. 3 3 Year Limited Warranty. 8/2016

Laboratory Open Scroll Quadplex with Premium Controls Model Dim. A Dim. B Dim. C Optional Outlet LSQ1005 66 107 * 84 2 1 ½ * LSQ1005 without remote inlet, Dim. B is 100. A B Laboratory Open Scroll Quadplex with Premium Controls SCFM @ 145 Tank Size psig (1) BTU/Hr db(a) System F.L.A. (1) System Level (1) 208V 230V 460V Weight (lbs) LSQ1005 10 (4) 100 200 97,600 80 114 103.6 52.6 3,500 1 SCFM values, BTU/Hr levels, and db(a) are shown with all pumps running. 2 Powerex recommends using performance ratings in SCFM (Standard Cubic Feet per Minute) when sizing laboratory air systems. 3 3 Year Limited Warranty. 8/2016

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Specification General The Powerex Laboratory Open Scroll Air Compressor System is designed to provide clean, dry air for applications where the quality of the compressed air is critical. The standard unit is rated for a maximum of 116 PSIG. Each system is completely tested before shipment and includes: Multiple oil-less scroll air compressors and associated equipment. Corrosion resistant air receiver. Desiccant air dryers with purge control. Control panel. Dewpoint monitor. The only field connections required will be system intake, exhaust, and power connection at the control panel. All interconnecting piping, wiring, and vibration isolation pads are included with the system. Open Scroll Air Compressor System The package shall include multiple oil-less scroll air compressors and associated equipment. The only field connections required will be system intake if remote intake option is chosen, exhaust, and power connection at the control panel. Oilless Scroll Compressor Pump Each compressor shall be belt driven oil-less rotary scroll single stage, air-cooled construction with absolutely no oil needed for operation. Direct drive compressors shall not be used. The rotary design shall not require any inlet or exhaust valves and shall be rated for 100% continuous duty. Tip seals shall be of a composite PTFE material and be rated for 8,000 hours operation. Compressor bearings shall be external to the air compression chamber and shall all be serviceable for extended compressor life. Bearing maintenance shall not be required until 8,000 run hours. Compressors with bearings that are not accessible for service have a limited life span and shall not be accepted. Compressors shall have an integral radial flow fan for cooling and shall not require any additional electric cooling fans. Each compressor shall have flexible connectors on intake and discharge, an electric drive motor, a discharge check valve, an aircooled aftercooler, a condensate separator* and a high discharge temperature shut down switch. Each compressor module shall have an isolation valve and a moisture separator* with automatic drain. Motor Each compressor shall be belt driven by a ODP NEMA construction motor. OSHA approved belt guards shall be provided. P 1.888.769.7979 F 513.367.3125 www.powerexinc.com Motor Slide Base Maintenance feature designed for easy adjustment of belt tension from the motor side on the basemount assembly. Robust single screw linear belt tension adjustment. Custom compact design. Service Slide The service slide enables easy maintenance access to each pump and motor basemount without having to remove them from the system. Unique maintenance-friendly base mount slide design. Allows safe access to important system components necessary for improved pump life. Allows faster component replacement time. Air Receiver The system shall include an ASME air receiver rated for 200 PSI MAWP. The tank shall be equipped with: A pressure gauge and a safety relief valve. By-pass valves to allow tank isolation without system shutdown. A sight gauge. An automatic electronic tank drain with manual override. The receiver shall be internally lined with an FDA approved material for corrosion resistance. Premium NFPA Control Panel The control system provides automatic lead/lag sequencing and automatic alternation of all compressors in order to equalize the amount of usage among the available compressors. The Premium NFPA Control Panel shall include a gateway server card and all features listed below: Building automation communication gateway with BacNet protocol and Web server features. Web server features include email notifications in case the system is in alarm or has achieved one of its maintenance intervals and requires service. Ethernet port for connection to BacNet server or direct connection to facility Ethernet for viewing of system operations and status via device IP-address. UL508-A listed control panel in a NEMA 4/12 enclosure. The panel door will include: 6 Color touch-screen HOA (hand-off-auto) switch for each pump 3-position Dryer control switch (Dryer1/Both/Dryer2) 95 db(a) alarm horn Acknowledge push-button (to silence the horn) The 6-inch color touch-screen will display: Pump status: On, Off, or Ready Pump Faults/Service state: High temperature, overload trip, service required Pump run hours System pressure System Dewpoint 01/2017 Page 1 of 2

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Trends Pump information screens will display pump maintenance intervals with required service System alarm screen: Low Pressure Alarm General Fault Alarm (Pump faults) Air Quality Alarm (Dewpoint or optional CO) Pump Maintenance required Dryer and monitor service notices Alarm log Dry contacts are provided on a labeled terminal strip for remote monitoring of all system alarms. Air Purification Package The air purification package shall consist of the following: dual desiccant air dryers, dual filter and regulator bank with sample ports, and dew point monitor with alarms, and all bypass piping. Piping to be brass, stainless, or type K copper, and cleaned for medical air use. All components shall be mounted piped and wired to the air receiver. Desiccant Air Dryers The twin-tower, heatless desiccant air dryer shall yield a pressure dew point of -40 degrees F. The dryer shall be installed and plumbed on a common steel skid to the air receiver (400 gallon and larger tanks are mounted separately). The dryer design shall be of the automatic pressure swing, heatless, regenerative type and shall include a purge muffler for quiet operation. The filtration system shall consist of 2 stages of filtration mounted and plumbed to the air dryer. The first stage of filtration shall include a.01 micron coalescing pre-filter with element change indicator and automatic condensate drain and installed up-stream of the air dryer. The second stage shall include a 1 micron particulate filter with element change indicator and installed downstream of the air dryer. Activated carbon final filters are optional. Dryer controls to include dryer alternating timer and slow acting automatic valves to open lag dryer for use based on dew point achieved. Each dryer is factory sized for flow with one compressor unit in reserve. Filtration and Pressure Reducing Station Each filter/dryer/regulator assembly shall be plumbed with bypass valves to enable service without disrupting air flow to the facility. Each assembly also includes a sample air port. The filtration systems consist of two stages of filtration as outlined above in the Desiccant Air Dryers section. Additionally, each assembly shall include a dual set of pressure reducing valves with pressure gauges installed downstream of the final filters and adjusted to an outlet pressure of 115 psig. P 1.888.769.7979 F 513.367.3125 www.powerexinc.com 01/2017 Page 2 of 2

Laboratory Air Duplex Package 7.5 & 10 HP with Premium Controls Model Dim. A Dim. B Dim. C Optional Outlet LSD0754 69 61 75 1 ½ ¾ LSD10B4 67 60 75 1 ½ ¾ Laboratory Air Duplex Package with Premium Controls SCFM @ Tank Size 100 PSIG (1,2) BTU/Hr db(a) System F.L.A. System Level (1) 208V 230V 460V Weight (lbs) LSD0754 7.5 (2) 46.2 120 38,167 74 40.4 36.6 19.3 2,200 LSD10B4 10 (2) 62.4 120 50,889 76 55 50 26 2,300 1 SCFM, BTU/Hr, and db(a) values listed are with all pumps running. 2 Powerex recommends using performance ratings in SCFM when sizing laboratory air systems. 3 Remote inlet optional 4 3 Year Limited Warranty. 10/2015

Laboratory Air Triplex Package 7.5 & 10 HP with Premium Controls Model Dim. A Dim. B Dim. C Optional Outlet LST0754 69 61 75 1 ½ ¾ LST10B4 67 60 75 1 ½ ¾ Laboratory Air Triplex Package with Premium Controls SCFM @ Tank Size 100 PSIG (1,2) BTU/Hr db(a) System F.L.A. System Level (1) 208V 230V 460V Weight (lbs) LST0754 7.5 (3) 69.3 200 57,250 77 59.6 53.9 28.0 2,900 LST10B4 10 (3) 93.6 200 76,333 79 81.5 74 38 3,100 1 SCFM, BTU/Hr, and db(a) values listed are with all pumps running. 2 Powerex recommends using performance ratings in SCFM when sizing laboratory air systems. 3 Remote inlet optional 4 3 Year Limited Warranty. 10/2015