Sirius SAT. Working towards a cleaner future. Heat Boxes with Wireless Data Transmission. heating specialists

Similar documents
Sirius FS. Working towards a cleaner future

Sirius WH. Working towards a cleaner future

Sirius SAT. Working towards a cleaner future. Built-in User Modules R/1 RP/1 RS RSP R2Z Installation and Operating Manual. heating specialists

Wall Hung Condensing Boilers. Working towards a cleaner future. heating specialists

General catalogue COMMERCIAL AND TECHNICAL INFORMATION. Commercial Range. March 2015 Edition

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

USER MODULES SIRIUS SAT M-BUS MODELS TRANSMISSION OF CONSUMPTION VIA CABLE INSTALLATION AND OPERATING MANUAL

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Installation & User s Instructions

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler

FASTflo. Working towards a cleaner future

Smart Collection. April 2012

Combi Eco Elite Range. User s Guide and Important Warranty Information

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

User s Operation Instructions & Important Warranty Information. High-efficiency wall-hung boilers Baxi Avanta Heat Only 15h - 18h - 24h - 30h

User s Operation Instructions & Important Warranty Information

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler

Contacts: Potterton. For latest prices and delivery to your door visit MyTub Ltd

A homeowner s guide to the Baxi Neta-tec Combi

ecotec plus 937 Power store high efficiency combination boiler

RIELLO 40 GS/M SERIES

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

Stored Water District Heating Interface Units. Heat Interface Units

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler

Residential Heating Boilers

COMPACT HRE ECO RF COMPACT HRE & ECO RF SMART CHOICE FOR HEATING AND HOT WATER

Avanta 12v - 15v - 18v - 24v - 30v

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

Avanta 24c - 28c - 35c - 39c 18s - 24s - 30s

SPECIFICATIONS - NIKE

Floor standing boilers. RMG Mk.II RS Mk.II

WALL-HUNG COMBINATION

INSTRUCTION FOR THE USER THC V E OIL BLU

Ideasandformsinevolution

Multifit. Installation & Commissioning Instructions

Easicom 2. Quality, Reliability, Flexibility

1 VICTRIX ZEUS Superior kw I features

Compact HRE and ECO RF Boiler Range. The smart choice for heating and hot water

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

OWNER GUIDE. Model 739 OPEN DECORATIVE GAS FIRE. (GC No )

User Guide. Promax SL Condensing Central Heating Boiler

Fitting & Commissioning Instructions. EcoBlue Combi and System Range. Outdoor Sensor Kit. Kit Part No (System) Kit Part No.

aquaplus High performance combination boiler with integrated power store

Easicom. Quality, reliability, flexibility

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE

RMG MK. II RMG Mk.II RS Mk.II RMG Mk.II RS Mk.II

turbomax plus High performance combination boiler range

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

ADVANCE ECB ELECTRIC COMBINATION BOILER

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

Statesman. Users Instructions. 45/50, 50/70, 70/90, 90/110, System, Flowsure, Flowsure +, Utility 50/70, 70/90, 90/110, 110/130, 130/150

Type summary Albatros 2

Baxi Brazilia F 5, F 5S, F 8S & Comfort Stat F 8ST Oak

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

New Zealand Sales Hotline: Sales Fax:

Baxi Combi HE Range. Baxi Combi HE. Keeping Britain Warm

ecomax pro High efficiency condensing boiler range for traditional systems

KIT UNITÀ AMBIENTE E INTERFACCIA A LED KIT ROOM UNIT AND LED INTERFACE RAUMGERÄT UND LED-SCHNITTSTELLE KIT APPAREIL D'AMBIANCE ET INTERFACE À LEDS

User Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe.

WLM3 the 3 rd generation of the OJ Waterline TM Control Systems. Industry leading intelligence, control SLIDE OJ Electronics

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

Sonnet Plus Anthem Genesis Soraya

WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILERS. Efficient, economical and easy

ACCUMULATION OF EUROPEAN CLASS

FCX FUEL OIL CONDENSING BOILER RANGE

The mechatronics of EVE 05

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

InTec 2 X HIGH EFFICIENCY BOILERS LOW CARBON SOLUTIONS

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

VICTRIX Superior kw Export VICTRIX Superior kw X Export

Model 809 Electric Heater

Control Products & Systems OEM

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

Herz York Direct Heat Interface Unit

WALL-HUNG HIGH EFFICIENCY GAS BOILERS

User Guide. Main Eco Elite Combi Condensing Central Heating Boiler

12.0 Servicing. Electrode Position Fig Annual Servicing Inspection (Cont) 4 ±0.5

Model 741FS. Dream, Heritage or Opulent OWNER GUIDE. INSTALLER: Please leave this guide with the owner Baxi Heating U.K. Limited 2007.

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

ELECTRIC HEATING SOLUTIONS PRODUCT RANGE

Biomass. Biomass solid fuel boiler range

User Guide. EcoBlue System Gas Fired Wall Mounted Condensing System Boiler

HT V2 HT Split

DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM

Baxi Maxflow Combi WM

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

PR / MP I Laboratory / Medicine

OWNER GUIDE. Model 750. INSET LIVE FUEL EFFECT GAS FIRE Fitted with Harmony, Avignon or Style fascia. (GC No )

Sonnet Plus Anthem Genesis Soraya

Advance Split

The guarantee on this appliance is valid for 12 months from the first day of installation.

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

T. +44 (0) E.

Transcription:

Heat Boxes with Wireless Data Transmission Working towards a cleaner future heating specialists

Intelligent Comfort Potterton Commercial, the UK s leading supplier of commercial boilers introduces an intergrated solution for delivering and recording the heat energy consumed by the individual dwelling in a block of apartments served either by a centralised heating plant or by a District Heating System heat boxes. Intelligent comfort and immediate recording (wireless transmission) Compact dimensions, energy saving, immediate information on consumption and equal cost are all guarateed by, ensuring that the desired room temperatures and hot water can be easily controlled and regulated. 2

integrated system for heat distribution and data recording Heat consumption meters for wireless transmission By Pass Valve Data reading is carried out via a wireless connection (network node) or locally. The heat consumption meter is built in to the. To guaratee the correct operation of in any installation. Modulating mixing valve Electronically managed to maintain the set temperature both in the heating and DHW circuit (only for RSP, RS2Z models). Climatic regulation Outdoor sensor available as optional for optimum climate control (subject to model). Telescopic tubes Included to facilitate system connection. Compact dimensions H x W x D 650 x 600 x 150mm Models R/RS RP/RSP RA H x W x D 750 x 800 x 150mm Models R2Z/RS2Z RA2Z DHW stainless steel heat exchanger range 35kW, to ensure the maximum efficiency also with a 60 C water temperature in the primary circuit (RS, RSP, RS2Z models) Heating only R RP with pump R2Z to manage two different zones (high and low temperatures) Heating and DHW production RS with DHW plate heat exchanger RSP with pump, and heating zone DHW plate heat exchanger RS2Z to manage two different heating zones (high and low temperature), and DHW plate heat exchanger RA with pump, connection with a DHW cylinder option RA2Z to manage two different zones (high and low temperatures), connection with a DHW cylinder option 3

Recording with wireless data transmission heat boxes are provided with heat consumption meters with wireless data transmission, without the need for a cable connection. A direct consumption reading is still possible via a digital display on the heat meter. Wireless transmission To save on meter reading time and respecting user privacy, consumption data can be communicated by a wireless signal sent from the heat consumption meters to the Network Nodes that receive and store data. Consumption data transmission made by heat meters is repeated 6 times a day. This automatic reading system allows the control of the building consumption from one single position quickly and with ease, avoiding possible reading errors. 4

The reading and transmission of consumption data can be done both locally and remotely using the optional accessories available. Direct transmission from network nodes Data transmitted by the network nodes can be directly downloaded from the remote reader device (optional) connected to a laptop. network node PC remote reader device Network nodes with gateway (RS232) remote transmission Data is read through a PC serial cable; the cable is connected to the main transmission network node positioned in the heating station. network node with gateway PC Network nodes with gateway (via GSM) remote transmission Data is read via the GSM telephone network through a PC connected to the main network node through a GSM modem. GSM network node BLOCK OF FLATS TO RECORD REMOTE OFFICE GSM modem PC 5

Heating only units R model RP model Heating circuit pump discharge head Discharge head (KPa) Water flow (l/h) R2Z model 6

Technical features Electronic heat consumption meter with wireless data reading (network node) Vertical hydraulic connections facing down Brass components with automatic by-pass and integrated hydraulic connections Telescopic tubes and taps included Circuit balancing valve (R model) Hydraulic connections on a hard painted and non-scratch frame Electronic components included in a case with grade of protection IP44 Complete diagnostics with leds (R2Z model) Anti-frost device (R2Z mod.) System to prevent pump and valves sticking (R2Z model) Low consumption circulating pump UPS 25/70 to autonomously control the water flow in the installation Inspectionable filter on the heating circuit Selection of 3 different climatic curves: high temperature (25/80 C), average temperature (40/60 C), low temperature (25/40 C) (R2Z model) Outdoor sensor connection option (RS2Z model) Possibility to control 2 different heating zones (R2Z model) Compact dimensions Galvanized steel case R RP R2Z Models with pump Models with 2nd heating zone Heating temperature regulation with high climatic curve C 25/80 Heating circuit maximum pressure bar 4 4 4 Water content Iitre 1.5 2 3,5 Power supply voltage V 230 230 230 Power supply frequency Hz 50 50 50 Power consumption W 15 110 210 Width of the case mm 600 600 800 Height of the case mm 650 650 750 Depth of the case mm 150 150 150 Net weight Kg 12 13 22 7

Heating and DHW production RS model RSP model RS2Z model RA model Heating circuit pump discharge head Discharge head (KPa) RA2Z model Water flow (l/h) 8

Technical features Electronic heat consumption meter with wireless data reading (network node) 35kW stainless steel plate exchanger that allows maximum efficiency also with water temperature at 60 C in the primary circuit (RS, RSP, RS2Z) Hydraulic connections facing down Brass components with automatic by-pass and integrated hydraulic connections Telescopic tubes and taps included Hydraulic connections on a hard painted and non-scratch frame Electronic components included in a case with grade of protection IP44 Complete diagnostics with leds Anti-frost device Low consumption circulating pump UPS 25/70 to autonomously control the water flow in the installation (RSP, RS2Z, RA, RA2Z models) Circuit balancing valve (RS model) System to prevent pump sticking (RSP, RS2Z, RA, RA2Z models) System to prevent valves sticking Domestic water filter Inspectionable filter on the heating circuit Selection of 3 different climatic curves: high temperature (25/80 C), average temperature (40/60 C), low temperature (25/40 C) (RSP, RS2Z, RA, RA2Z models) Outdoor sensor connection option (RSP, RS2Z, RA, RA2Z models) Possibility to manage 2 different heating zones (RS2Z, RA2Z models) DHW priority DHW temperature control by electronic modulation Compact dimensions Galvanized steel case RS RSP RS2Z RA RA2Z DHW production Models with pump Models with 2nd heating zone Heating temperature regulation with high climatic curve C 25/80 25/80 25/80 25/80 25/80 DHW regulation C 30/60 30/60 30/60 35/65 35/65 DHW production with T=40 C and inlet I/min 14.3 14.3 14.3 14.3 14.3 water temperature 75 C Heating circuit maximum pressure bar 4 4 4 4 4 DHW circuit maximum pressure bar 8 8 8 8 8 DHW circuit minimum pressure bar 0.2 0.2 0.2 0.2 0.2 Water contents litres 2 2.5 4 2 4 Power supply voltage V 230 230 230 230 230 Power supply frequency Hz 50 50 50 50 50 Power consumption W 15 110 210 150 210 Width of the case mm 600 600 800 600 800 Height of the case mm 650 650 750 650 750 Depth of the case mm 150 150 150 150 150 Net weight Kg 16 18 28 16 25 9

Installation solutions Here are some examples of applications in centralised plant room installations serving buildings with more than one dwelling. Potterton Commercial high efficiency Sirius range condensing boilers are installed in the main plant room. DHW heating The measurement of heat production is assigned to the user who, with, can autonomously adjust the dwelling comfort level according to their own needs whether this is space heating or hot water. DHW heating Solution 1 Centralised DHW production In the first solution the DHW production is centralised: Sirius SAT (heating only models) manages the distribution of heat within the dwelling. DHW heating cylinder 10

Solution 2 DHW heating Local DHW production In the second solution, in addition to managing the space heating, also produces DHW with a plate heat exchanger for the dwelling. The diagram represents the distribution of the built-in heat-boxes on the floor, outside the dwelling to provide ease of access for direct meter reading or servicing. DHW heating DHW UNIT A SIRIUS SAT UNIT B SIRIUS SAT UNIT C heating SIRIUS SAT Supply example Here are the basic and optional components necessary for a residential complex comprising 32 dwellings (26 RSP heat-boxes and 6 RS2Z heat-boxes) divided in 2 blocks of 4 flats. (The distance between the 2 blocks must not be more than 25 metres). 26 RSP heat-boxes heating and DHW production 6 RS2Z heat-boxes heating and DHW production and 2 heating zones control (high and low temperature). This is simply an indicative example. Necessary components x 26 x6 x 26 x6 600 x 600 x 150 cases 750 x 800 x 150 cases RSP RS2Z Optional components x 32 x 32 Volumetric meters for domestic cold water Remote control and room sensor Optional components For data transmission of recording (via GSM) x4 Network nodes (two pieces for each block of flats) x1 Network nodes with gateway (via GSM) remote transmission x1 Software ACS 26 for remote data reading 11

Hydraulic schematic HEATING ONLY MODELS RP R2Z RP R2Z 1 ON-OFF valve 2 Heat consumption meter 3 Heating pump 4 Low temperature mixing valve 5 High temperature ON-OFF valve 6 Low temperature circuit pump 7 High temperature circuit pump 8 NTC heating sensor A Heating system flow B Heating system return C Heating inlet from centralised system D Heating return to centralised system E High temperature heating system flow F High temperature heating system return G Low temperature heating system flow H Low temperature heating system return RSP RS2Z HEATING AND DHW PRODUCTION MODELS RSP RS2Z 1 ON-OFF valve 2 Modulating valve 3 DHW/heat 3 way valve 4 Pressure switch 5 Heat consumption meter 6 NTC heating sensor 7 NTC DHW sensor 8 Mixing valve 9 DHW-heating pump 10 High temperature heating pump 11 Low temperature heating pump 12 High temperature ON-OFF valve A Heating system flow B Heating system return C Heating inlet from centralised system D Heating return to centralised system E DHW outlet F Cold water inlet G High temperature heating system flow H High temperature heating system return I Low temperature heating system flow L Low temperature heating system return RS RA 2 8 3 1 5 9 6 3 1 6 7 4 5 A E C D F B A E C D F B RA2Z 9 8 1 3 6 12 5 10 G I E C D F L H 12

Dimensions R, RP, RSP, RA screws seats connection tongues case width 150 connection kit 30 38,5 50 H case 650 L 600 front view 50 64 left side view R2Z, RS2Z, RA2Z screws seats connection tongues case width 150 The uprights of the centralised heat source can be accessed also via the sides of the case connection kit 30 38,5 50 H case 750 L 800 front view 50 64 left side view 13

Heating connections R, RP, RS, RSP, RA P case 600 R2Z, RS2Z, RA2Z P case 800 Centralised system connections DHW system connections IP: UP: primary inlet from centralised system 3/4 M primary outlet to centralised system 3/4 M ES*: US: DHW inlet 1/2 M (RS, RSP, RS2Z models) DHW outlet 1/2 M (RS, RSP, RS2Z models) Heating system connections one heating zone models MR: RR: heating 3/4 M system flow heating 3/4 M system return DHW consumption meter connections ESC1*: DHW inlet to heat meter 3/4 M ESC2*: DHW inlet to the second heat meter 3/4 M (R, RP, R2Z models) Heating system connections two heating zone models MRAT: high temperature 3/4 M system flow (R2Z and RS2Z models) MRBT: low high temperature 3/4 M system flow (R2Z and RS2Z models) RRAT: high temperature 3/4 M system return (R2Z and RS2Z models) RRBT: low temperature 3/4 M system return (R2Z and RS2Z models) * in case of installation of the cold water meter (available as an optional extra) the DHW inlet has to be transferred in the hydraulic connection ESC1 (or ESC2). 14

Supplying and mounting system heat boxes are supplied with metal case and separator device; the device is supplied already assembled. The case is made of galvanized steel with the frame and door coated with an anti-scratch paint. case frame door Hook Luna SAT on the case template and proceed with the hydraulic connections. Optional accessories Thermo regulation QAC34: outdoor sensor The inlet temperature of the installation is set according to the outdoor temperature. If the outdoor sensor is linked with a remote control, the inlet temperature considers the average outdoor temperature over the last 24 hours and adjusts the climatic curves automatically. Room thermostat (RT) Thermostat for regulation of room temperature. Remote control and room sensor (R2Z, RSP, RS2Z models) set the room and DHW temperature weekly timer on 6 levels of daily temperature ability to manage an additional thermostat or phone activator anomalies indicated holiday setting function Data transmission Network node* Receipt of the data from heat consumption meters present on the floor and wireless transmission to the next network node. Network node with gateway (RS232) Wireless reading of the consumption and data transmission through a serial cable to a local managing system. Network node with gateway for trasmission via GSM Wireless reading of the consumption and data transmission via GSM to a remote managing system. Remote reader device Device for data receipt at a short distance. Room thermostat (RT) Thermostat for the regulation of the room temperature. Software ACS 26 It allows the reading of the recording data of the whole system transmitted by network nodes with gateway (via GSM). Control* First cold water meter DHW and DCW meter with hydraulic accessories RP and R2Z models RSP and RS2Z models *battery life: 5 years Second cold water meter RP and R2Z models 15

Commercial sales technical & service enquiries Tel: 0845 070 1055 Fax: 0845 070 1059 Sales hotline: 0845 070 1056 Technical helpline: 0845 070 1057 Service hotline: 0845 070 1058 e-mail: potterton.commercial@baxigroup.com web: www.pottertoncommercial.co.uk Spares Potterton Commercial spares are available nationwide through the interpart network of approved stockists. Alternatively please contact:- Interpart Brooks House Coventry Road Warwick CV34 4LL Tel: 08706 000454 Fax: 08706 000545 Applications & Installations Our experienced technical and applications team are available to offer advice on any aspect of heating system design and boiler installation. Please contact: 0845 070 1057 Commercial service offices Our service organisation covers the whole of the UK to look after your needs for all Potterton Commercial products. We are also able to offer our services for other manufacturer s products. Our service office offers a wide range of specialised services including: Boiler site assembly Burner commissioning for all fuels Boiler maintenance and service contracts Breakdown and repair services Burner and boiler replacement Oil/gas conversions Systems conditioning Water treatment and descaling Packaged units All descriptions and illustrations contained within this leaflet have been carefully prepared, but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information in this leaflet. Publication Date: 0709 Baxi Commercial Division Wood Lane, Erdington, Birmingham B24 9QP Email: potterton.commercial@baxigroup.com www.pottertoncommercial.co.uk Sales: 0845 070 1056 Technical: 0845 070 1057 heating specialists