Air Make-Up Units. Product Line Overview & Capabilities

Similar documents
Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260)

Indirect Gas-Fired Make-Up Air

Modular Supply Make-Up Air Unit

Modular Heating & Ventilating Unit Model IGX-HV

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

THE ULTIMATE ROOFTOP SOLUTION

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Selecting the Correct Fan

Direct Fired Heater Model AD Specification

AIR HANDLER SPECIFICATION

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

BULLETIN G-99. March 2005 CONDENSED CATALOG. Air Moving Products

ALL PRODUCTS BROCHURE

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Direct Gas-Fired Make-Up Air

Our energy efficient experts and engineers have made ground breaking innovations in this field.

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

RoofPak Applied Rooftop Systems

YORK COMMERCIAL AND INDUSTRIAL SUPPLY AND EXHAUST FANS. YORK Commercial and Industrial Supply and Exhaust Fans. Creating air-flow efficiencies

KIC Air Curtains. Technical Guide

AFD Industrial Dehumidifier Series

PRODUCT GUIDE THE NEW YORK BLOWER COMPANY

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

MLR SERIES MODULAR AIR HANDLING UNITS

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

CML Northem Blower Inc. Air Movement Equipment

PRODUCT HANDBOOK A Complete Product Overview

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Direct Gas-Fired Make-Up Air Models DG and DGX

XeteX, Inc. All Rights Reserved.

Cultivator & Hybrid Cultivator

Product Handbook. Moving Your Way. Our Complete Product Offering. PennBarry Manufacturer of Ventilation Products

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

All the products you need for. Engineered Kitchen Ventilation Systems.

Centeral Station Air Handling Unit

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Make-Up Air Systems. Performance. Model DGK, DG, DGX

HARTZELL. Tempered Air Heating Equipment. Hartzell Fan, Inc., Piqua, Ohio

Air-Handling System Cooling Options

Glossary of Terms Laboratory & Fume Exhaust Fans

62DA,DB,DC,DD,DE,DF07-38

The H Series. Pure and Simple Solutions. HTLV Space Heating

1.1 This section applies to air handling units for HVAC Systems.

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING

SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT. Fans, Heaters & Controls

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

AHU ENERGY RECOVERY VENTILATORS ERV DEDICATED OUTDOOR AIR SYSTEMS DOAS HEATING, COOLING & DEHUMIDIFICATION AHU

Direct Gas-Fired Make-Up Air Models DGK, DG and DGX

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

Energy Labs Energy Labs Energy Labs Energy Lab

Best Practices for Applied Rooftop ` Systems, Applications and. Jerry Cohen President Jacco & Assoc. Installation

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

INDUSTRIAL BLOWERS. With over 70 years of experience and expertise our fans will ensure your projects are a success.

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

AFD DEHUMIDIFIER SERIES

INTRODUCTION.3 PRODUCT SPECIFICATIONS. 3

Make-Up Air March 2012

TYPICAL CPA SPECIFICATIONS

Appendix 13. Categories of Cooling and Heating systems

INDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION REFRIGERATION

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

Energy Recovery with Cooling and Heating

H2O COIL. Heat Exchange and Air Movement Products Product Preview

LARGE CAPACITY HEATERS

hinged tops or hinged doors.

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

TEXTILE AIR ENGINEERING EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY

TECAM S.A. Environmental Technology

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

OPERATION & MAINTENANCE MANUAL MODEL SC-924A SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

A. Codes and Standards that are Standard at the University:

Air-Handling System Cooling Options

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

Twin City Fan & Blower

MXI Mixed Flow Inline Fan

Dry desiccant dehumidification systems. Product guide

Fans: Features and Analysis

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

Table of Contents. Laboratory Fume Hoods. UniFlow Fume Hood Systems. Fume Hood System Components. Custom Hoods, Enclosures & Cabinets

Direct Fired Units w/ Packaged Cooling

INDIRECT GAS-FIRED AIR HEATER

AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

Transcription:

Air Make-Up Units Product Line Overview & Capabilities

Air Make-Up Units Customized Solutions Unmatched Flexibility As one of the most sophisticated manufacturers of Air Make-Up Units, Aerovent s unique ability to customize our products for the exact application is second to none. By leveraging our comprehensive product offerings and 3D modeling technology, Aerovent has the knowledge and engineering expertise to provide customized solutions for our customers project-specific needs. When you partner with Aerovent, not only do you get the product flexibility you require, you also get the highest quality products and construction features to meet your precise specifications. And with a wider range of sizes, custom components, and specialized coatings, we can provide more options and controllability than any manufacturer. Validation UL 508 Electrical Control Panel Certification ANSI Z83.4 Construction ETL Listing Z83.4 100% Outside Air Z83.18 Recirculated Air NEMA 12 Control Enclosures and NEC Oil tight Wiring Standards AMCA 210 Fan and Blower Performance Tested in accordance with AMCA 210 Procedures FM & IRI Insurance Standards as required Laboratory/Field Testing & Startup Services Sound & Air Performance Testing Vibration Testing Seismic Testing (test lab only) Equipment Commissioning Controllability Factory installed controls are available with a wide range of options and can be customized to interface with automated building management systems Customer Drawings Customer drawings are available in 3D, 2D and Revit files formats 2 AEROVENT AIR MAKE-UP UNITS

Air Make-Up Units IndustriesServed > Automotive > Paper & Pulp > Power Generation > Food Processing > Chemical Processing > Wastewater & Sewage > Manufacturing > Foundries > Pharmaceutical > Textile > Warehousing > Mining > Transit Stations > Steel Mills > Marine TypicalApplications > Heating > Cooling > Humidifying > Energy Recovery > Air Filtration / Fresh Air Supply > Air Turnover > Door Air Heaters > Process Heating or Cooling > Product Dryers > Paint Finishing Systems WWW.AEROVENT.COM 3

AMU Product Options Heating > Direct Gas Fired > Direct Gas Fired with 80/20 Recirculation > Indirect Gas Fired > Modulating > Face & Bypass > Integral Face & Bypass > Modulating Electric Heat Cooling > Air Cooler Spray Type > Air Cooler Media Type > Chilled Water > Direct Expansion Refrigerant Humidification > Mist spray Humidification > Steam Humidification Energy Recovery > Air to Air Aluminum Flat Plate Cross Flow > Rotary Heat Recovery Wheel > Heat Pipe Filters > Pleated Filters > Metal Filters > Bag Filters > Cartridge Filters > HEPA Filters > Available in a Wide Range of Efficiency V-Bank Carbon Filters Motor Removal Rail Direct-Fired Gas Heat Velocity Meter 4 AEROVENT AIR MAKE-UP UNITS

AMU Product Options Configurations > Top Horizontal > Bottom Horizontal > Upblast > Downblast > Vertical Air Flow Up > Vertical Air Flow Down > Rooftop Mounted (with Curb) > Rooftop Mounted (without Curb) > Outdoor Pad Mounted > Indoor Mounted Controllers Stand Alone Controls > Outlet Temperature Control (OTC) > Modulating Room Temperature Control (MRTC) Direct Digital Control (DDC) Systems > DDC Compatible Take control of Equipment with Existing DDC System > Factory Supplied DDC System FM or IRI Pipe Train Discharge Sensor Fan Types > Centrifugal SWSI > Centrifugal DWDI > Axial > Plenum > Spark Resistant Construction > Painted Mild Steel > Stainless Steel > Galvanized > Aluminum > Full Welded or Bolted DDC Controls Tamper-Proof Control Station WWW.AEROVENT.COM 5

Product Line Overview Industrial Direct-Fired Gas Models FCBT & BIBT Direct-fired gas air make-up units are a complete air supply system in a self-contained package with fan, burner, and controls. The units are ready for connection to the gas line and power source. These systems are for use in industrial or commercial applications where supplying tempered outside air is required. Standard Construction Heavy-duty forward curved or backward inclined DWDI centrifugal blower 14-gauge welded steel housing Peaked roof to eliminate standing water 0 to 92 degree temperature rise Dual fuel burner Factory assembled and tested Remote operating station V-Bank Filter Section Direct-Fired Gas Heat Heavy Industrial Direct-Fired Gas Models GACDW & GA Model GACDW Centrifugal Gas-fired air make-up units are complete air supply systems for the ultimate in safety and dependability. These packaged units are available in axial and centrifugal types. The equipment is designed for tempering outside air and supplying it into the building for ventilation make-up and balancing of negative pressure. The units are also adaptable to other applications where ordinary heating or drying operations are involved. Model GA Axial Standard Construction Heavy-duty industrial Centrifugal DWDI BI BIA, or Axial Fans Welded 12 gauge steel housing Peaked roof to eliminate standing water 0 to 92 degree temperature rise Dual fuel burner Factory assembled and tested Remote operating station 6 AEROVENT AIR MAKE-UP UNITS

Steam Models S, SACSW & SACDW Product Line Overview Steam distributing tube coil gives good temperature distribution, maximum freeze protection, and allows the tubes to expand without transmitting stresses to the tubes. Propeller and centrifugal models are available. The centrifugal unit is available with an industrial backward inclined or airfoil wheels, as well as a commercial duty forward curved fan. Units come assembled and include fan, coil, vacuum breaker, and motorized shutter. Industrial Backward Inclined Fan Commercial Duty Forward Curved Fan Gas Door Air Heaters Model DAH Door Air Heaters temper the sudden influx of cold air when an overhead door is open. To mix hot and cold air, it is necessary to create a highly turbulent condition directly in front of the door. The Gas Door Air Heater provides a high velocity blast of hot air to mix with the sudden influx of cold air. Performance 6200 CFM unit has outlet velocity of 3500 FPM. 4100 CFM unit has outlet velocity of 2300 FPM. Spray Type Air Coolers Model AC The spray type air cooler is an enclosure containing three elements: a spray bank consisting of nozzles for producing a fine spray from water supplied to them under pressure, an eliminator for removing water from air passing through the air cooler, and a basin for collecting the used water to be returned to the pump for recirculation. This same cooler can work as a highly efficient heat absorber when provided with chilled water from a mechanically refrigerated chiller or from a well (well water temperature 55 F (12.7 C) or lower). WWW.AEROVENT.COM 7

Offering A Full Line Of Custom Air Make-Up Units Vertical Gas Fired Air Coolers Direct-Fired Gas Heat Hot/Chilled Water High Temperature (Plug Fans)e Electric Heat Air Make-up Direct Drive Propeller Gas Heat Fume Exhaust Energy Recovery WWW.AEROVENT.COM 5959 Trenton Lane N Minneapolis, MN 55442 Phone: 763-551-7500 Fax: 763-551-7501 AV-AMU Brochure - 1MWG10/13