EWS3 WIRELESS INDOOR SIREN

Similar documents
EKB3W WIRELESS LED KEYPAD

EWP2WIRELESS MOTION DETECTOR

Тел: Моб: Skype: Discoverytelecom Mail: EWK2 EWK2A WIRELESS KEYFOB

1. CONTENTS OF PACK 2. TECHNICAL SPECIFICATIONS ... User Manual v1.1. Compatible with: ESIM264 v and up. ESIM364 all versions

1. Package content. User Manual v1.3

EWR2 WIRELESS SIGNAL REPEATER

EWF1 EWF1CO WIRELESS SMOKE DETECTOR WIRELESS SMOKE & CO DETECTOR

Any additional devices linked to the system ET08 (computer, sensors, relays etc.) must be approved by LST EN standard.

COMMUNICATOR ET08 / ET081

EP364 USER MANUAL ALARM AND MANAGEMENT SYSTEM

External Wireless Sounder

EWF1 WIRELESS SMOKE DETECTOR

Other trade names mentioned in this document may be registered trademarks or trademarks of respective product manufacturers or vendor products.

External Wireless Sounder

PITBULL ALARM. GSM Alarm System

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

NEW GENERATION WIRELESS ALARM SYSTEMS

New generation wireless alarm systems

Ion Gateway Cellular Gateway and Wireless Sensors

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

MOBILE CALL GSM Alarm System User s Manual

CG500SKE SKYEYE GATEWAY USER MANUAL VERSION OCTOBER Disclaimers and Copyright

1126 Series Ceiling Mount PIR Motion Detector

Installation and Operation Guide EXTERNAL SIREN

System. For a better understanding of this product, please read this user manual thoroughly before using it.

Condominium Security Management System

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

USER MANUAL Mobeye ThermoGuard CM2200

Contents. Glossary

EVO192 v3.0 Fire and Burglary What s New

ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet

Watchguard WGAP864 User Manual

1. Introduction. 2. Product overview

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

JA-63 Profi User manual

Сontrol panel Contact GSM-9N

Independent Zone Control (I.Z.C.)

Wireless Keypad GKP-S8M

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

User s Information Guide R2A

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

Wireless Keypads LKP(E)S8M Series

3 User s settings. 3.3 Internal clock setting

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

Solution Ultima 862 Operators Manual ISSUE 1.10

Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A

Version 1.03 January-2002 USER S MANUAL

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

IDS816 User Manual H Issued January 2009

GSM ALARM AND MANAGEMENT SYSTEM ESIM264 COMPLIES WITH EN GRADE 2, CLASS II REQUIREMENTS

Total Connect Box. User manual

DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel

Intelligent Wireless GSM Alarm System

X64 Wireless Training

Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual

>WIRELESS> ALARM SYSTEM CR200

My Visonic SMS App User Guide

Wireless External Alarm

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

Smart Home Outdoor Siren

Alarm System SECURE AS 302

ET082 GSM/GPRS COMMUNICATOR

All-In-One Wireless Security System V1.0. Model #: MG-6060

S3 Sim Secual Alarm system with GSM transmitter

GSM RFID VOICE Alarm System

Advisor Advanced User Guide

ET083 2G/3G COMMUNICATOR

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

Wireless Alarm system s manual

Always Armed, Never Disarmed User Guide

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

G4S SMARTalarm User Guide

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

2-ZONE EASYFIT INTRUDER ALARM

Quick Reference Guide

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

Installation and ZONES: Operation Manual. Model: ON STI-34108

installation & operation manual

READ ME FIRST DIY WIRELESS ALERT. Gate Alert Kit. Instruction Manual


Home Doorway Alert Kit

DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel

PROGRAMMING PROCEDURES (Table 3)

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

ALMDT-2000 INFRARED MOTION SENSOR

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher

READ ME FIRST DIY WIRELESS ALERT. Driveway Alert Kit. Instruction Manual

WIRELESS DOOR/WINDOW CONTACT ACCESSORY (WHA3)

Engineer Reference. EN :2006+A1:2009 EN :2009 EN :2008 EN :2005+A1:2008 Security Grade 2 Environmental Class II

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

Installation Manual Premier 412/816/832. Issue 10

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

Table of Contents. All-In-One Wireless Security System V1.3. Programming Guide. Model # MG-6060 / MG-6030

System Introduction. 1.1 Specifications

PERMACONN PM1030 Includes DI300. Installation Manual

Transcription:

EWS3 WIRELESS INDOOR SIREN

User manual v1.2 Compatible with: ESIM264 v7.14.07 and up. ESIM364 v02.06.09 and up.. ESIM384 all versions. EPIR2 v01.01.12 and up. EPIR3 all versions. PITBULL ALARM all versions. PITBULL ALARM PRO all versions. Main features: Audio alarm indication by 2 built-in speakers. Visual alarm indication by built-in LED indicators: Burglary/24-hour/tamper alarm and fire alarm indicated in different colours. 2 tamper switches: for enclosure opening and device detachment from the wall detection. Built-in temperature sensor. EWS3 is a wireless indoor device with built-in siren speakers and LED indicators operating with ELDES wireless alarm systems. The de vice is designed to notify the user by audio and visual signals in the event of alarm as well as in event of system arming/disarming (Bell Squawk feature must be enabled). In the event of Burglary, 24-hour or tamper alarm, EWS3 will activate the speakers and flash the blue LED indicators, while in case of a fire alarm, the device can flash the red LED indicator (both features require EWS3 Alarm LED and EWS3 Fire Alarm LED parameters to be enabled using ELDES Configuration Tool software or EKB2/EKB3/EKB3W/EWKB4 keypad) To start using EWS3, it has to be paired with ELDES alarm system by sending a corresponding SMS message or using software ELDES Configuration Tool. Upon successful EWS3 pairing process, the system adds one wireless zone and one wireless PGM output. In case of alarm, the siren provides a sound alarm for one minute (maximum duration of sound alarm - up to 6 minutes (configurable). ESIM264, EPIR2, EPIR3, PITBULL ALARM and PITBULL ALARM PRO alarm systems support up to 16 EWS3 devices, while ESIM364 and ESIM384 - up to 32 EWS3 devices. The maximum wireless connection range is 150m (492.13ft) (in open areas). NOTE: For complete information on device operation with ELDES alarm system, please refer to ELDES alarm system user and installation manuals located at www.eldesalarms.com 1. CONTENTS OF PACK Item Quantity 1. EWS3... 1 2. 1,5V Alkaline AA type batteries... 4 3. Screws... 4 4. User manual... 1 2. TECHNICAL SPECIFICATIONS 2.1. Electrical & Mechanical Characteristics Battery type... 1,5V Alkaline AA type LR6 (IEC) / 15A(ANSI/NEDA) Number of batteries...4 Battery operation time...~18 months* Acoustic sound level... >90 db measured at 1m (3.28ft) Wireless band...ism868/ism915 Range of operating temperatures...-25 +55 C (-13... +131 F) Humidity...0-90% RH @ 0... +40 C (0-90% RH @ +32... +104 F) (non-condensing) Dimensions...167x80x34mm (6.57x3.15x1.34in) Wireless communication range...up to 30m (98.43ft) in premises; up to 150m (492.13ft) in open areas Compatible with alarm systems...eldes Wireless * The operation time might vary in different conditions. 2 EN EWS3 Wireless Indoor Siren

2.2. Main Unit, LED & Connector Functionality FRONT SIDE of PCB BACK SIDE of PCB 1 - BATTERY + TAMPER BUZZER - BATTERY + + BATTERY - - BATTERY + TAMPER STATUS ALARM (blue) ALARM (red) ALARM (blue) RESET BUZZER RESET Button for restoring default parameters + / - Battery slots STATUS LED indicator for data transmission indication ALARM (blue) Blue LED indicators for visual alarm indication ALARM (red) Red LED indicator for visual alarm indication BUZZER Speakers for audio alarm indication TAMPER Tamper switches 2 FRONT SIDE of ENCLOSURE ALARM (blue) ALARM (red) ALARM (blue) LED indication ALARM (blue) flashing ALARM (red) flashing Description Burglary, 24-Hour or tamper alarm in progress Fire alarm in progress EWS3 Wireless Indoor Siren EN 3

3. INSTALLATION NOTE: Before installing the wireless device, we highly recommend to refer to RADIO SYSTEM INSTALLATION AND SIGNAL PENE- TRATION manual located at www.eldes.lt/download 1. Open EWS3 enclosure. 3 4 2. Once the enclosure is opened, fix the siren to the wall using the screws. MOUNTING POINT A 5 6 MOUNTING POINT A Ensure to screw in properly for supervision of the back side by tamper switch MOUNTING POINT B 3. When installing EWS3, follow the recommendations for the installation to achieve the strongest wireless signal: 7 Wireless device Never install in the following locations: inside the metal cabinet closer than 20cm (7.87in) from the metal surface and/ or power lines 8 Wireless device 0,5 to 30m (1.64 to 98.43ft) inside the building 0,5 to 150m (1.64 to 492.13ft) in open areas Wireless antenna Recommended: face the front side of the wireless device towards EL- DES alarm system s wireless antenna keep the distance: 0,5 to 30m (1.64 to 98.43ft) inside the building, 0,5 to 150m (1.64 to 492.13ft) in open areas 9 Wireless device 0.5 m to 30 m (1.64 to 98.43ft) inside the building 0.5 m to 150 m (1.64 to 492.13ft) in open areas EPIR3 Recommended: face the front side of the wireless device towards the front side of EPIR3 keep the distance: 0,5 to 30m (1.64 to 98.43ft) inside the building, 0,5 to 150m (1.64 to 492.13ft) in open areas 4. Remove the plastic tab inserted between one of the battery terminals and battery slot contacts. 10 5. STATUS indicator should start flashing indicating successful data transmission. 4 EN EWS3 Wireless Indoor Siren

6. Close EWS3 enclosure by putting the cover back. 11 12 7. Pair the device with the alarm system using ELDES Configuration Tool software. Open Wireless Device Management section and enter a 8-digit wireless device ID located on the EWS3 enclosure and press Add button. The device can also be paired by sending a corresponding command via SMS text message. For more details, please refer to the software s HELP section and ELDES alarm system installation manual. 13 8. Upon the successful pairing process, the message indicated next to EWS3 device icon will turn to CONNECTED. If the attempt to pair is unsuccessful, try to move EWS3 closer to the ELDES alarm system and pair anew. 9. EWS3 siren is ready for use. ATTENTION: Ensure that EWS3 device is properly fixed to the wall and the Mounting Point A portrayed in fig.#5 and fig.#6 is properly screwed in. Otherwise, the tamper switch will NOT supervise the back side of EWS3 enclosure (see also 4. EWS3 ZONE, PGM OUTPUT AND TAMPER). NOTE: If you are unable to pair the wireless device, please restore the parameters of the wireless device to default and try again (see chapter 7. RESTORING DEFAULT PARAMETERS). EWS3 Wireless Indoor Siren EN 5

4. EWS3 ZONE, PGM OUTPUT AND TAMPER Upon successful EWS3 device pairing process, the system adds 1 wireless Instant-type zone and 1 wireless Siren-type PGM output. The wireless zone is intended for EWS3 tamper control and ability to assign a partition (-s), while the wireless PGM output is intended for siren speaker control. In case of tamper violation, the alarm is caused regardless of system being armed or disarmed. There are 2 ways to detect tamper violation on EWS3: By tamper switch. EWS3 comes equipped with 2 built-in tamper switches intended for enclosure supervision: one located on the front side of the PCB supervising the front cover in case it is illegally opened (see fig.#1). the other one located on back of the PCB supervising the back side of the enclosure in case the EWS3 is illegally detached from the wall (see fig.#1). Once the enclosure of EWS3 is tampered, the tamper switch will become triggered. This action will be followed by alarm, resulting in sending an SMS text message and/or phone call to the user. The SMS text message contains the violated tamper name. By wireless connection loss. The wireless connection loss between EWS3 and ELDES alarm system leads to alarm. The system identifies this event as a tamper violation and sends alarm by SMS text message and phone call to the user (-s) by default. The SMS text message contains the wireless device model, wireless ID code and tamper name. The user will also be notified by SMS text message as soon as the wireless signal is restored. ATTENTION: The tamper will not operate if the wireless zone is disabled. 5. TEMPERATURE SENSOR The device comes equipped with a built-in temperature sensor allowing to monitor the temperature of the area surrounding EWS3 device. When using the with EPIR3 alarm system, you may set the MIN and MAX temperature thresholds ranging from -25 C to +55 C resulting in SMS text message delivery to the listed user phone number once exceeded. The accuracy of temperature measurement depends on the environment s temperature boundary, which is +5 C. The accuracy of the temperature measurement will be +/-1 C at the temperature above +5 C and +/-2 C at the temperature below +5 C. 6. BATTERY REPLACEMENT 1. Open EWS3 enclosure. 2. Remove all 4 old batteries from the battery slots. 3. Position the 4 new 1,5V alkaline AA type batteries according to the appropriate battery slot positive/negative terminals indicated on the PCB (printed-circuit-board) of EWS3 4. Insert the batteries into the battery slots. 5. Batteries replaced. See chapter 3. INSTALLATION for more details. ATTENTION: Only 1,5V Alkaline AA type batteries can be used. Install only new, high quality and unexpired batteries. Do not mix the old batteries with the new ones. ATTENTION: At least 1 battery must be removed if the device is not in use. ATTENTION: In order to avoid fire or explosion hazards, the system must be used only with approved battery. Special care must be taken when connecting positive and negative battery terminals. Dispose old batteries only into special collection sites. Do not charge, disassemble, heat or incinerate old batteries. NOTE: The system sends an SMS text message to the listed user phone number as soon as the battery level runs below 5%. NOTE: The battery status can be monitored in real-time using ELDES Configuration Tool software. 6 EN EWS3 Wireless Indoor Siren

7. RESTORING DEFAULT PARAMETERS 1. Remove one battery from EWS3. 2. Press and hold the RESET button. 3. Insert the battery back to EWS3. 4. Hold the RESET button until LED indicator starts blinking. 5. Release the RESET button. 6. Parameters reset to default. 8. ADDITIONAL INFORMATION Limited Liability The buyer must agree that the system will reduce the risk of fire, theft, burglary or other dangers but does not guarantee against such events. ELDES UAB will not take any responsibility regarding personal or property or revenue loss while using the system. ELDES UAB liability according to local laws does not exceed value of the purchased system. ELDES UAB is not affiliated with any of the Internet providers therefore is not responsible for the quality of Internet service. Manufacturer Warranty This device carries a 24-month warranty by the manufacturer ELDES UAB. Warranty period starts from the day the system has been purchased by the end user. The warranty is valid only if the system has been used as intended, following all guidelines listed in the manual and within specified operating conditions. Receipt must be kept as a proof of purchase date. The warranty is voided if the system has been exposed to mechanical impact, chemicals, high humidity, fluids, corrosive and hazardous environment or other force majeure factors. Safety instructions Please read and follow these safety guidelines in order to maintain safety of operators and people around: DO NOT use the system where it can be interfere with other devices and cause any potential danger. DO NOT use the system with medical devices. DO NOT use the system in hazardous environment. DO NOT expose the system to high humidity, chemical environment or mechanical impacts. DO NOT attempt to personally repair the system. The WEEE (Waste Electrical and Electronic Equipment) marking on this product (see left) or its documentation indicates that the product must not be disposed of together with household waste. To prevent possible harm to human health and/or the environment, the product must be disposed on in an approved and environmentally safe recycling process. For further information on how to dispose of this product correctly, contact the system supplier, or the local authority responsible for waste disposal in your area. Copyright ELDES UAB, 2018. All rights reserved It is not allowed to copy and distribute information in this document or pass to a third party without advanced written authorization by ELDES UAB. ELDES UAB reserves the right to update or modify this document and/ or related products without a warning. Hereby, ELDES UAB declares that this wireless indoor siren EWS3 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. The declaration of conformity may be consulted at www.eldesalarms.com EWS3 Wireless Indoor Siren EN 7

Made in the European Union www.eldesalarms.com