JEREMIAS GROUP. CE MARK according to EN / 2.

Similar documents
Technical Guidance CE Marking of Metal Chimneys and Flues

TWIN - GAS. Concentric flue gas system for decorative gas fires.

EXHAUST SYSTEMS COMMERCIAL CHIMNEY LINING SYSTEMS.

PUCCI S.r.l. COMPONENTS AND ACCESSORIES FOR GAS BOILERS 0051 CPD CPD 0081

PUCCI S.r.l. COMPONENTS AND ACCESSORIES FOR GAS BOILERS 0051 CPD 0080

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

CHAPTER 8 CHIMNEYS AND VENTS

CHAPTER 8 CHIMNEYS AND VENTS

CHIMNEYS AND VENTS CHAPTER 8

TW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40

Importance of a Draught Regulator

Eligibility criteria

Part J of the Building Regulations: Changes for 2010 Tuesday 28 th September 2010 Presenter: David Bleicher

FireFlexmaster. A Multi Fuel Flexible Chimney Liner 10 year Manufacturer Guarantee. 172 Ferry Lane, Stanley Wakefield, West Yorkshire, WF3 4LT

Pellet Vent INSTALLATION INSTRUCTIONS

Esse B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL

INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT

Furenflex RWV Advanced Liner

Twin Wall Installation Instructions And Maintenance Guide

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

Assessment Schedule - TS.6

Irish Standard I.S. EN :2009

General Guidance on the selection and installation of flues and chimneys for wood burning and multi fuel appliances in residential properties.

Annex 5a Solid fuel (Domestic) Annex 5a Common Minimum Technical Competency Requirements for Solid fuel burning appliance installation (domestic)

COMPANY PROFILE.

INSTALLATION AND OPERATION MANUAL

AUTOMATIC MAKE-UP AIR DAMPER WITH TRANSFORMER READ AND SAVE THESE INSTRUCTIONS

SFA Guide to Building Regulations and Solid Fuel Heating

Microgeneration Certification Scheme: MCS 008

Forced Draft Boiler Flue Gas Venting: Problems & Solutions. Presented by Steve Connor and Patrice Gouin January 27, 2016

Domestic Gas Safety Assessments (DGA) Competency Assessment Certification Scheme for Registered Gas Installers

Flues and chimney systems

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

Commissioning of Heat Producing Appliances Burning Solid Fuel

Boiler Technical Specifications (2013)

AIEA Presentation. Wood pellets heating systems.

Single Wall Flue system. Installation manual WARNING. Installation Manual CoxDENS PPs MC-CG-105 EN_892054

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Solid fuel hot water boiler TKH KW INSTRUCTIONS MANUAL for usage and maintenance

PLAN THE INSTALLATION Planning the installation first requires selecting the most appropriate installation approach. The chart below offers suggestion

Installation & Manual. Model T-25

Riva Studio Dedicated Sealed External Air Kit

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Permanent Ventilators (for the Supply of Combustion Air)

Direct Vent System Required

STATEMENT OF SOLID FUEL APPLIANCE PERFORMANCE

Evaluation Guideline. regarding the Product Certificate GASKEUR Label HR (High Efficiency, Heating):2010 for Central Heating Appliances

CE Marking for Fire Resistant doors. The future EN Agustín Garzón Cabrerizo Technical Director Fire Resistance Lab.

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

anti-condensation valve

INSTALLATION & COMMISSIONING INSTRUCTIONS Model: 990 CH

The stove pictured on the cover is the Evo 30 (see page 9)

natural warmth of the house A compact boiler designed to combust ecological fuel- pellet ORLIGNO 500 Compliant with EN norm

RS Chimney Fan for Solid Fuel Applications

Why our flame is so natural... Our Technology & Engineering Excellence. Efficiency. Safety & Reliability. Fully Remote Controlled

USER MANUAL 9kW LILLY PELLET STOVE

Maintenance 50 Serie CAUTION. Before resetting your electronic card that displays an error code. OVERHEAT MESSAGE

According to the following European Regulations which come into force:

The intelligent alternative for flue gas venting systems

RS Chimney Fan for Solid Fuel Applications

PVE SERIES POWER VENTER SYSTEM MANUAL

POWER VENTER. Model: PVE Series

TONAdin triple-wall insulated chimney of round design. TONAtec plus air/flue chimney for all fuel types (specifically biogenic solid fuels)

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM

VPC Gas Cabinet Heater Range

2012 INTERNATIONAL FUEL GAS CODE VENTS

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Bevent Rasch. FIDs. - Fire /05/18

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Flue & Chimney Systems

EXCEL. ULTRABlack THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY NEVER EVER BUY ANOTHER STOVE PIPE

The stove pictured on the cover is the Evo 30 (see page 7)

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

Commercial Flue Guide

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Guidance from the Group of Notified Bodies for the Construction Products Directive 89/106/EEC

Skorstenar Utförandestandard för metallskorstenar

WOLVERTON STOVES U S E R M A N U A L S h A N d o N / A R d L E i g h

Window and Door Standards for Performance and Security. Russell Day Senior Technical Officer Glass and Glazing Federation

PowerVent. Installation manual (GB) English. Store this document in a safe place UK

Advanced Venting Systems

Riva F40 Cube. Multi-Fuel Free Standing Stove. Installation Instructions. Models: RVF40C. For use in Great Britain and Eire IMPORTANT

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

CP+ Gas & Oil Cabinet Heater Range

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 110 ECO RANGE FEATURES AND BENEFITS

MODEL ANSWER FOR ELEMENTS OF MECH.ENGG.(17413) 1) steam boiler- It is a closed vessel in which steam is produced from water by combustion of fuel.

Introduction. General. Other regulations. British Standards and European Technical Specifications

OPERATING INSTRUCTIONS with safety features

AIM OF THE EXPERIMENT:- Study of boilers (fire tube, water tube) APPARATUS REQUIRED: - SL.NO NAME OF THE APPARATUS SPECIFICATION QUANTITY 01 Fire tube

UltraOil Condensing Oil Boiler

Rocket heater GAMERA

Website:

Inspection Checklist Mechanical Rough in

Flues and chimney systems

DNVGL-CP-0407 Edition February 2016

Building Constructions 4

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

Fire dampers. For diverse applications

Transcription:

JEREMIAS GROUP CE MARK according to EN 1856-1 / 2

CE MARK according to EN 1856-1 / 2 WHAT DOES THE CE MARK MEAN FOR STAINLESS STEEL CHIMNEY SYSTEMS? The CE MARK is the symbol obligatory since April 2005 that certifies that a stainless steel chimney is in accordance with the EN 1856-1. This standard specifies the performance requirements for rigid single and multi-wall system chimney products with metallic liners (chimney sections, chimneys fittings and terminals, including supports) used to convey the products of combustion from appliances to the outside atmosphere. It also specifies the requirements for marking, manufacturer s instructions, product information and evaluation of conformity of the product to the standard. The EN 1856-1 does not apply to self-standing chimneys. 30.08.2013 Page: 2

CE MARK according to EN 1856-1 / 2 WHAT DOES THE CE MARK MEAN FOR STAINLESS STEEL CHIMNEY SYSTEMS? The manufacturer is obliged to realize the complete initial test of the chimney in a laboratory, and moreover, a Certified Body will: 1. -annually check that the manufactured product has the same quality as the tested one 2. -perform the quality control of the production process to ensure that it will satisfy the CE requirements, specified in the FPC (Factory Production Control). The CE MARK of the stainless steel chimney can only be granted by a Certified Body. The CE Mark enables the product to circulate freely in the European market, but each country could have its own installation rules 30.08.2013 Page: 3

CE MARK according to EN 1856-1 / 2 CE MARK LABEL 1. Standard 2. Temperature Level 3. Pressure Level 4. Condensate resistance 5. Corrosion resistance 6. Flue liner material specification 7. Soot fire resistance (O: no; G:yes) 30.08.2013 Page: 4

CE MARK according to EN 1856-1 / 2 CE MARK LABEL 1- Standard EN 1856-1 for vertical chimneys EN 1856-2 for connecting pipes 2- Temperature Level Maximum working temperature. The temperature used in the test and the resulting temperature levels achieved are as follows: As guidance, the temperature ratings applicable are: T200: all gas and oil applications (including condensing) T450: solid fuels and multifuels T600: power generators and CHP s 30.08.2013 Page: 5

CE MARK according to EN 1856-1 / 2 CE MARK LABEL 3- Pressure Level Admitted overpressure inside the flue, with its corresponding leakage rate As guidance, the pressure ratings applicable are: N1: natural draught installations P1: forced draught boiler installations H1: power generators, CHP s and micro CHP s 30.08.2013 Page: 6

CE MARK according to EN 1856-1 / 2 CE MARK LABEL 4- Condensate resistance Suitability of the flue for wet or dry conditions. D: the flue is suitable only for dry conditions. It does not resist condensate. W: the flue is suitable whether for dry and wet conditions. It resists condensate water inside. 5- Corrosion resistance Level of corrosion resistance due to the products of combustion of the different kinds of combustibles and different working conditions (dry or wet) V1: Tested and approved as resistant to attack from products of combustion from gas. V2: Tested and approved as resistant to attack from products of combustion from light oil (sulphur content <0,2%) and natural wood in dry conditions, and from gas in wet conditions (condensing appliances) V3: Tested and approved as resistant to attack from products of combustion from heavy oil (sulphur content >0,2%), solid fuels and peat in dry conditions Vm: Not tested. The manufacturer certifies only the material used in the inner wall by the quality certificate of the steel. For flues with this class there are specific regulations in each country indicating what material is suitable for each installation. As general guidance the stainless steel AISI 304 is equivalent to class V1, and the stainless steel AISI 316L is equivalent to classes V2 and V3 30.08.2013 Page: 7

CE MARK according to EN 1856-1 / 2 CE MARK LABEL 6- Flue liner material specification The material of the inner liner must be specified and its minimum thickness as well: After that the minimum thickness of this inner liner is specified as follows: 040: 0,4mm 050: 0,5mm 060: 0,6mm 30.08.2013 Page: 8

CE MARK according to EN 1856-1 / 2 CE MARK LABEL 7- Soot fire resistance (O: no; G: yes) Soot fire resistance and minimum distance to combustible material It is expressed as G if the flue System has been tested, and as O if not. This classification is followed by the minimum distance (in mm) to combustible material. The test is a thermal shock of 1.000ºC during 30 minutes during which the System must endure and the temperature of combustible materials placed at the declared distance must not exceed 100ºC at an ambient temperature of 20ºC. The systems with O classification have not passed this test, so they cannot be used for any installation where the products of combustion contain soots (solid fuels, multifuels...). For low temperature applications, for instance room sealed boilers, where joints are used 30.08.2013 Page: 9

CE MARK according to EN 1856-1 / 2 CE MARK LABEL 8- Other declared characteristics: The characteristics of the previous points must be indicated in all documents of CE marking Hereinafter is a list of other characteristics that only appear in the DoP. (Declaration of Performance) Compressive strength (height for installation) Flow resistance of chimney sections fittings and terminals Minimum thermal resistance Flexural tensile strength Maximum distances between supports in non vertical installation Wind load resistance (maximum distances between fixing points and freestanding above the last one) Freeze thaw resistance 30.08.2013 Page: 10

Jeremias Group Quality JEREMIAS GROUP QUALITY COMPROMISE Jeremias is one of the world`s leading manufacturers of flue and chimney systems for the exhaust of gases and ventilation, covering all kind of domestic, commercial and industrial applications. Jeremias product range include 60 different CE certified systems covering commercial and domestic applications complemented by freestanding Industrial steel chimneys up to 3 meter diameter. Besides this compulsory CE Certification, Jeremias has also special certifications and listings needed in specific countries under i.e.; BS, Hetas, Swiss, Russian or US standards. For further information, Jeremias can supply technical guidance on various standards including the latest version of the European Standard 1856-1/2:2010. Please contact our certification department. 30.08.2013 Page: 11

Jeremias Group APPROVALS & CERTIFICATIONS 30.08.2013 Page: 12

System overview DOUBLE WALL SYSTEMS DW AL DW KL DW-KL DW VISION DW MAMMUT 30.08.2013 Page: 13

System overview SINGLE WALL SYSTEMS EW-FU EW-ECO EW-ALBI EW-Line FLEX EW-LAS 30.08.2013 Page: 14

System overview SINGLE WALL SYSTEMS EW-KL SV-EI-30 EW-VH EW-PPS EW-PPS-FLEX 30.08.2013 Page: 15

System overview PLASTIC & CONCENTRIC & DOUBLE WALL SYSTEMS CASCADE TWIN-PL TWIN-P DW ECO2.0 DW FU 30.08.2013 Page: 16

System overview SHAFTS & WALL-, FLOOR- AND ROOF SLEEVES FUMOLUX A/F FUMOLUX-P FURADO LUX FIX/VARIO LUX ECO 30.08.2013 Page: 17

System overview SHARE COLLECTIVE CHIMNEY & VENTILATION SYSTEMS SED SEE SET CLV SVC 30.08.2013 Page: 18

System overview STOVE PIPE & ACCESSORIES, VALVES, DAMPERS, SILENCERS FERROLUX AIR SUPPLY SYSTEM PELLET PIPE ACCESSORIES SILENCERS 30.08.2013 Page: 19

Jeremias Group INTERNATIONAL PROJECTS