RTU. Roof Top Units 8 30 Ton. Maxi-Kool.

Similar documents
System Floor Mount Systems DX / Glycol / Chilled Water 6-12 Tons. High Density Presicion Cooling. Kompact.

Flexible & Innovative. Cooling Solutions

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

System 2100 & System 2100k

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

MACH N-407 Heat Pump Air-Cooled Chiller

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

AIR COOLED PACKAGED CHILLER

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

SECTION COMPUTER ROOM AIR CONDITIONING SYSTEMS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

MAC N-407 Air-Cooled Chiller

Advance Release September 2009

1.1 This section applies to air handling units for HVAC Systems.

Guide Specifications for InRow Direct Expansion

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Product Chillers A P P L I C AT I O N S

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

SECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

Series 8. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Series 6. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

Modular Supply Make-Up Air Unit

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

PACKAGE AIR CONDITIONER

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

PAJ3. Product Specifications

Direct Fired Heater Model AD Specification

Liebert CSU3000 Chiller

A. Codes and Standards that are Standard at the University:

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

C13-Series Engineering Guide

SECTION WATER-SOURCE UNITARY HEAT PUMPS

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

ENGINEERING MANUAL 3, 5, & 7 TONS PRECISION ENVIRONMENTAL CONTROL

.2 Section Waste Management and Disposal.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

AIR HANDLER SPECIFICATION

SKYPAK II, 3 Ton Series, gives you a

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Mission Critical Air Conditioning Systems

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

VertiCool Aurora Engineering Guide

MAC-120HE-03 Air-Cooled Chiller

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

SKYPAK II, 3 Ton Series, gives you a

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

HVAC REPAIR/REPLACEMENT 07/18/12 SECTION HVAC - MAJOR EQUIPMENT

Modular Heating & Ventilating Unit Model IGX-HV

VariCool VAV Engineering Guide

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

CoolSpot Engineering Guide

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Direct Fired Units w/ Packaged Cooling

Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities R-410A. ISO 9001 Certified

Direct Gas-Fired Make-Up Air Models DG and DGX

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

Direct Gas-Fired Make-Up Air

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

T P A 120 S 4 S N 1 Y

PAR5. Product Specifications

RHEEM PACKAGE GAS/ELECTRIC

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

RGE 13 A T - 1 A

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

2 shp 13 lc 1 36 t - 1 a

Model 655A Sizes

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

Transcription:

Maxi-Kool RTU Roof Top Units 8 30 Ton www.compu-aire.com

MK A-3 034 -RTU Maxi-Kool Type Air Cooled - A Chilled Water Cooled - C Glycol Cooled - G Water Cooled - W Nominal Tonnage 8 30 Ton Voltage 2-208 3-380 4-460 5-575 Roof Top Unit

RTU Maxi-Kool Roof Top Units The computer room environmental control system shall be COMPU-AIRE self-contained-packaged factory assembled, internally wired, piped, factory run tested, and fully charged with R-410A. Unit shall have Horizontal Supply and Return Air, and Horizontal condenser air intake and discharge. The unit shall be factory furnished with Remote Microprocessor Control Panel. The System shall have a total and sensible cooling capacity as shown in the technical data sheet. Units shall be ETL listed as a package.

Cabinet Cabinet shall be constructed of heavy gage galvanized steel. Double Wall Access panels shall be provided for ease of service. Supply & Return air openings shall have 1 duct flanges(s) for ducting the evaporator air. Evaporator section shall be insulated with 1.5, 2 lb high density R-13 insulation and the condensate pan shall be stainless steel. Mounting rails shall be provided with the unit. Rubber and shear pads are to be by others. Weatherized Cabinet RTU Unit Cabinet shall be weatherized for outdoor installation. The Hood and Bird Screen shall be installed on the Condenser Supply and Discharge. The Unit shall be painted with Compu- Aire Standard Enamel Finish. Double Wall Construction Cabinet exterior access panels shall be constructed of double wall construction. Each access panel shall be reinforced with additional heavy gauge metal with insulation on both panels. Allowing a maximum vibration, noise and thermal insulation (attenuation) during system operation. DUCT CONNECTIONS: Evaporator section will have be provided in a bottom supply; bottom return configuration. Note: Roof curbs shall be supplied by others. Evaporator Blower Section The air conditioner shall be configured for draw-thru air pattern to provide uniform air flow over the entire face area of the coil. The unit shall have DWDI blower(s). Each shall be the centrifugal type with forward curved blades, both dynamically and statically balanced. The blower(s) shall operate in the Class-I range, shall be belt driven, and rated in accordance with AMCA Standard #210. The speed of the blowers shall be adjustable by means of a variable pitch motor pulley. Drive and dual belts shall be sized for 200% of the motor horsepower rating, and shall be oil and heat resistant and static conducting. Unit Construction The unit frame shall be of 14 gauge tubular steel MIG welded and QC inspected for rigidity and shape. The welding techniques shall be either T-joint or corner joint with a 1/16 bead. The unit frame shall be mounted on two 1/8 thick tubular steel mounting rails with fork lift cutouts. The cabinet construction shall be of 18 gauge sheet steel. The drain pan shall be of welded stainless steel construction. The blower shall have permanently lubricated pillow block (L- 10) bearings, with an average life span of 200,000 hours. The blower shaft shall be cold finished center-less ground heavy-duty steel, treated for rust protection. The shaft shall conform to ASTM A-108 specifications. Evaporator Blower Motor The blower motor shall be Premium Efficiency Motor, shall have resilient base and mounted on the blower housing. The motor shall be 1725 RPM and shall have copper windings, phase isolation and shall be UL component.

Air Flow Switch Maxi-kool ROOF TOP UNIT is equipped with airflow switches that continuously monitor the supply airflow and turn the unit off with alarm in case of loss of airflow. The unit also monitors pressure drop across the air filters and provide dirty filter alarm (indication only). Field calibration is required for dirty filter alarm. Filtration The air conditioners shall have Filter Rack with 30% efficient filters as measured by ASHRAE standard 52-76. The filters shall be 2 inches deep with full depth filter pleats. Filters shall be UL Class II. Filter access shall be from the side of the unit. Dehumidification Cycle When MAXI-KOOL-ROOF TOP UNIT is switched to the dehumidification mode, a call for cooling is energized via the advanced microprocessor and moisture is condensed on the cooling coil. The condensate is then discharged through the primary condensate drain. The reheat provided shall offset sensible cooling during dehumidification and has sufficient capacity to maintain computer room dry bulb conditions. Electric Reheat MAXI-KOOL-ROOF TOP UNIT standard reheat is provided in multi-stage two, three or four stages. The low-watt density, electrically enclosed elements are surrounded by fin tubular construction elements, thus extending the life of the elements, reducing sheath temperatures and eliminating ionization. Reheat operation is protected by dual temperature limit controls. In the dehumidification mode the system selected has ample reheat capacity to maintain dry-bulb conditions. Steam Generating Modulating Humidifiercanister Type MAXI-KOOL-ROOF TOP UNIT is provided with a prepiped and pre-wired electronic, electrode selfgenerating steam type humidifier. The humidifier shall have an adjustable humidity output setting of the full rated humidifier capacity. The pure steam method eliminates air contaminating mineral deposits and excessive humidity inherent with evaporative or infra-red humidifiers. Pre-piped and prewired electronic, electrode self-generating steam modulating type humidifier. The humidifier has a modulating output control to match its output with humidity requirement signal. Humidifier shall come standard with an automatic flush cycle that senses the current consumption of the humidifier. The humidifier is equipped with disposable cylinder and an indicator that signals when the canister is to be changed which insures reliable, trouble free operation. The humidifier is complete with supply and drain valves, electronic controls and steam distributor. Vapor produced is piped directly into the bypass air for Evaporator Coil The Evaporator Coils shall be slab design and have face area as listed in the technical data sheet. The Refrigerant flow shall be controlled by Thermostatic Expansion Valve. The prime surface shall be seamless copper tubes with aluminum fins. Return bends shall be made of seamless copper tube. Coils shall be tested at 350 psig. Coils are rated in accordance with ARI Standard #410. FINS Shall be aluminum plate type, die formed fin design to provide optimum strength and turbulence for maximum peak performance without objectionable high pressure drop. Condensate Drain Pan The Condensate Drain Pan Shall be of stainless steel construction with nonferrous connections.

Water Overflow Sensor Condensate pan shall be provided with a moisture sensing device which when triggered (In the event the drain gets clogged), will shut the unit off and also send a signal to the remote MCP control panel. Condenser Coil The condenser coil shall have aluminum fins bonded to copper tubes and shall have full collars that completely cover the copper tubes. The coil shall also be designed for counter flow application for high heat transfer efficiency. Headers and connections shall be copper and shall be factory split to provide an independent condenser circuit for each compressor. The coil shall be pressure tested, sealed and pressurized for shipment. Condenser Fan The direct drive fan blades shall be aluminum, and shall be protected by a heavy gauge, steel wire, zinc plated, epoxy coated fan guard. Each fan section shall be separated by full width baffles to prevent bypass air. Condneser Motor The condenser motors shall have permanently lubricated sealed ball bearings, with inherent overload protection. Motors shall be mounted inside the condenser casing for weather protection. Low Ambient Fan Speed Control The Propeller Fan Condensing Unit shall be provided with a VARISPEED PACKAGE FOR LOW AMBIENT DOWN TO -20 F: Consisting of factory installed solid state pressure control. The capillary sensor senses the head pressure of operating compressor and control the variable speed fan to properly maintain the head pressure. A single phase variable speed motor shall be factory installed on the condenser fan. The speed controller modulates air delivery in direct response to head pressure and maintain minimum head pressure required.

Dual Refrigeration Circuits MAXI-KOOL-ROOF TOP UNIT is equipped with two high efficiency Scroll Compressors located in a separate compartment, outside the air stream for ease of service access during unit operation. Scroll compressors high volumetric efficiency and a constant volume ratio give the scroll compressor an excellent EER. Moreover, the capacity, power and the current do not fall off as rapidly at high condensing and low suction temperatures as a typical reciprocating compressor. Scroll compressor can also accommodate liquid slugging, both oil and refrigerant without causing compressor damage. Scroll compressors contain fewer parts resulting in greater reliability. Sound attenuation is also much easier since the dominant sound characteristics are in the higher octave band and the unit enclosure usually is adequate. Vibration in the system is greatly reduced by elimination of the reciprocating masses found in the semi-hermetic compressor. The System 2200 Plus Microprocessor includes an automatic compressor sequencing which assures equal usage of the two compressors, each compressor is provided with: Built-in thermal overload protection Crankcase heaters Rotolock valves Internal Vibration Isolation Charging and service schraeder ports Internal Discharge gas vibration eliminator External vibration mounting isolation Refrigerant Circuit(S) Each refrigerant circuit is provided with highly efficient refrigeration components. Externally equalized expansion valve Sight glass with moisture indicator Filter drier Pump down cycle (air cooled units) Schraeder fittings Hot gas bypass when required Suction accumulator when required Safety First! Each compressor system has an automatic reset low pressure switch for loss of refrigerant charge protection and manual reset high pressure switch for high pressure protection. Audio and visual alarm shall be provided with system shut down in the event of high/low pressure system failure.

Control Power Panel Maxi-Kool ROOF TOP UNIT is equipped with a high voltage panel which is easily accessible from the front of the unit and can be accessed for full service without disrupting the air flow. All wiring conforms to National Electrical Code (NEC) and UL 1995 requirements. Electrical components utilized in the control panel are UL Listed and recognized. Each AC power circuit is individually branch circuit protected on all three phases. Each component (humidifier, compressors, motor, electric reheat stage)(if applicable) is provided with a factory mounted and wired definite purpose contactor. The control wiring is 24 VAC low voltage. The control panel has the following components: Each electrical component such as fan motor, compressor shall be individually protected with branch circuit fuses. The Control Panel shall contain: Fuse-block with Fuses Transformers Circuit breakers for transformers Contactors Ground connection Low voltage terminal block. Power Block Disconnect Switch MAXI-KOOL-ROOF TOP UNIT requires a single point main power supply connection. UNIT DISCONNECT SWITCH (NON-FUSED) The manual disconnect switch shall be mounted in the high voltage section of the electrical panel. Disconnect Switch shall be operational from the outside of the unit with the door closed. The remote air cooled condenser shall be supplied with a factory mounted weather-proof control box, incorporating all the fan actuators, terminal boards and Ambient T-stat(s) required to provide head pressure regulation.

Compu-Aire Inc. 2200 + Series Control Keeping the control in your hands Compu-Aire Inc. has always focused special attention on simplicity of use, while at the same time fully exploiting the potential for flexibility and power offered by microprocessor technology. Compu-Aire Inc. offers a diverse range of programmable controls, with state of the art user interfaces, including touch screen displays. Compu-Aire Inc. 2200+ Series control provides a versatile approach to monitor the precise cooling and heating needs of your critical applications. With the latest technology available to the customer, we are able to provide reliable and flexible features to allow the customer to manage even the most intricate application. Compu-Aire Inc. user friendly controllers support a variety of communications and protocols, including BacNet, LonWORKS, FTP, HTML, and Modbus. Graphical Touch Screen Display Graphical status update with a touch of a button pco Web card interface provides: Unit status with virtual information Room temperature/humidity Current set points for temp/humidity Mode of operation Current status for vital components such as compressors humidfiers, fan and reheat Current active alarms Setpoint control for alarms The pco web card configuration interface provides limited access to control room temp/humidity a log with the ability to reset alarms. NOTE: Critical alarms will require manual reset at the unit level.

Programmable Local Area Network Local and remote monitoring can be achieved with our advanced microcontroller. Based systems are used to provide standalone supervision and control over a plan network giving the flexibility of a BMS system at the fraction of the cost. The plan communication option allows two or more systems to talk to each other, plan can be programmed for system rotation and for system failure over redundancy. Supports up to 16 units Lead/lag with multiple active & standby Unit rotation and auto changeover Alarm switchover to standby Assisted cooling Assisted heating Assisted humidification Dehumidification Hello Hello

Dimensional Data

While every precaution has been taken to ensure accuracy and completness in this brochure compuaire Inc assumes no responsability for damages resulting from use of this information or for any error or ommissions. Subject to change without notice.