AUDIT OF BUILDING RESOURCES The following pages provide a description of the fire safety equipment installed in the building including: Fire Alarm and Detection Systems Central Station (Fire Alarm System Monitoring) Standpipe Systems Sprinkler Systems Portable Fire Extinguishers Automatic Extinguishing Systems Emergency Lighting Building Emergency Generator Exits from Floor Areas Fire-Fighters Elevators Smoke Control Equipment To provide information on the location of other equipment and devices refer to Schematic Drawing in Section VI, Appendix G. SECTION I Page 10
Fire Alarm and Detection System: Manufacturer: Cerberus Pyrotronics Model: MXL - IQ Type:??Single-stage???Two-stage? Supervised: Yes? No?? Location of Main Panel: Location of Annunciator Panel(s): Main Electrical Room Front Lobby Sprinkler valve supervision: Yes # Zones: Eleven (11) Upon activation of the fire alarm system, the following will occur:??alarm will be transmitted to the Reek Building s panel which will send a signal to the central monitoring station??hvac system will shut down??bells and Strobe lights will be activated in the building??strobe Light on the building South exterior will flash to identify to Fire Department which building is in alarm Location of Fire Alarm Devices are as follows: DEVICE Manual Pull Stations LOCATION All Building Exits Smoke Detectors Air Ducts Various Rooms Heat Detectors Not Applicable Refer to Schematic Drawing Section VI, Appendix G SECTION I Page 11
Fire Alarm System Monitoring: Name of Monitoring Damar System Number 620051 Company: Address: 506 Christina Street, Sarnia, Ontario Telephone: (519) 336-7413 In the event of an alarm the Fire Alarm Monitoring Station will notify the following in order: 1. Chatham Fire Department - Global 2. SNC-Lavalin ProFac Inc. 519-674-5155 3. Morris Galick 519-674-5332 4. Morris Galick Cell 519-359-2739 5. SNC-Lavalin ProFac Call Centre 1-877-677-6322 Standpipe and Hose System: Not Applicable at this Building Provide details on:??the size and location of fire hose connections??the size and location of hoses in hose cabinets??fire department pumper connection(s)??location of fire protection system isolation valves Sprinkler System: Provide details on:??sprinkler system type Wet?? Dry????Location of main isolation control valves Boiler / Mechanical room??main supply shut-off location: Boiler / Mechanical room??test valve Boiler / Mechanical room locations: SECTION I Page 12
??Location of fire department North side of Building connection??system coverage Full?? Partial?? If partial coverage, describe sprinklered areas: Automatic Kitchen Extinguishing System(s): Not Applicable at this Building Location(s): Name of Company: Model: Extinguishing Agent: Coverage: Location of Manual Pull- Handle: Type of Fuel for Cooking: Automatic Fuel Shut-Off: Yes?? No?? Smoke Control System: Stairwell Pressurized Yes? No?? Elevator Shaft Yes? No?? Pressurized Smoke Shafts Yes? No?? Other Information Emergency Lighting (Battery Type): Manufacturer: Model: Type: SECTION I Page 13
Installed in the following areas: First Floor Electrical Room, Second Floor Electrical Room Building Emergency Generator: Not Applicable at this Building Provided Yes? No?? Automatic?? Manual? Location: Equipment Fuel: Make and Model of Emergency Generator Is emergency power provided to all elevator cars Yes? No?? simultaneously? Is emergency power provided to smoke control pressurization N/A fans? Other systems provided with emergency power? Shut off Controls: Location of Natural Gas Shut- Off Location of Hydro Shut-Off Location of Water Shut-Off Exterior of North West corner of building Old Agronomy Exterior Sub Station Ground Floor North Boiler Room Portable Fire Extinguishers: Type Floor Location Number Multi-Purpose Dry Chemical 1 st Floor Class A, B and C Fires South Exit 033648C West Exit 033643C East Exit 033651C North Exit 003642C Kitchen 033647C Room 119 783580 SECTION I Page 14
Storage Room #151 Operating Room Mechanical Room 2 nd Floor South Exit North Exit Mechanical Room 033646C 038542C 009130C 033652C 033653C 009132C Private Fire Hydrants: There are a total of 18 fire hydrants throughout the complex. Refer to Schematic Drawing Section VI, Appendix G for exact locations. NOTE: The main shut off for the Hydrant System is located in the Valve Chamber on the front lawn at South East Corner of Steckley Hall. Elevators: Make: Otis Make: Type: Hydraulic Type: Capacity: 15 Capacity: Location: East Centre Core Location: Serves: Ground and Second Floors Serves: Exits from all Floor Areas: (refer to Schematic Drawing in Section VI, Appendix G for locations) XXXXXXXXXXXXXXXX Basement Number of Exits Available Ground Floor Number of Exits Available Typical Floor Above Grade Number of Exits Available SECTION I Page 15