SHUTTLE BELL-PRESS DIMMER DATA SHEET

Similar documents
Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

Universal pushbutton dimmer etd U2 etd 2e

GI1DPC/B User Guide. Mains tungsten GLS filament or halogen lamp Min 60W Max 300W. Linear fluorescent

Trailing Edge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

TrailingE dge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

C-Bus Four Channel Analogue Output Unit Installation Instructions

DALI Product Range. Designed in Australia to be compatible for all DALI systems. gerardlighting.com.au

Use of the application program

Connections, displays and operating elements C D E G H. Installing the control unit

Welcome. Please read this manual carefully, and ensure that you are comfortable with the instructions before attempting to install the smart dimmer

Operation Manual Model: Light Switch Combo Universal Dimmer Module Item No.: WMR-252. Specification. Wiring

Universal Dimmer E450UD Series. Installation Instructions

Push Button Electronic Timer. 31VETR Series. Installation Instructions

Commercial Grade Lighting Controls Collection

Product Bulletin for Decora Rocker Slide Controls

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Reflector T2 and GU10 6,000 hours


Dimmer Switch (3 Gang)

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

LED LIGHTING TECHNOLOGY

Push Button Electronic Timer. 31VETR3 Series. Installation Instructions

START-LINE Receiver ACD-200. SMART Home USER MANUAL. Version 1.0 Visit for the most recent user manuals MAINS SOCKET DIMMER

DIMAX DIMAX D GB F I E NL. Installation and operating instructions Universal dimmer DIMAX 532. Minimum DIMAX 532.

Integrated PIR detectors

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

LED Dimming control and load compatibility.

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

GRAFIK T Controls GRAFIK T

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

The Remote alarm Panel, TYPE RAPv2

EN , EN , DALI 102/207, SELV Output, KS C 7655 Safety Certification Approved RoHS Compliant. Dim. Method

Abella Digital Fade Dimmer

HomeWorks QS Architectural RF GRAFIK T Local Controls

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

GRAFIK TTM Controls GRAFIK TTM. Wallbox Controls

C-Bus Four Channel General Input Unit Installation Instructions

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

LED SUPERSTAR MR16 35 ADV 24 /36 Product description

Power Factor (2) 350 ma 90 ~ 132 Vac Vdc 35 W 86% 0.95 LLC-040S035RSP. Efficiency (2)

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Remote Controls POOL SPA & FILTRATION SUPPLIES (PTY) LTD REMOTE SYSTEMS

A low energy alternative to halogen which provide energy savings of around 90%

Dimming expertise LED UNIVERSAL ROTARY DIMMER

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Controlling LEDs to meet. Russ MacAdam Director of Engineering Development

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

TROPO 15W Dimmable LED Driver

Monitored Pneumatic Valves On Series Ported Manifold

RE-PR3-E-27 3-Phase Panel Mount 27kW

INTERNATIONAL STANDARD

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Hi-lume 3D Overview. Fluorescent Dimming Ballasts Hi-lume 3D Architectural Dimming

Operation and Maintenance Manual OM 897-3

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

M15051) INSTRUCTION MANUAL

Lighting and Energy Control

½ Monitored Pneumatic Valves On Series Ported Manifold

Dimmable General Area Use High Bay 320 Watt LED Light Fixture - Low Profile - High Efficiency

REA 105 Arc Protection Module. Operator s Manual

Trios Training Manual

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

DIMAX DIMAX 534 plus D GB F I E nl. Installation and operating instructions Universal dimmer. DIMAX 534 plus

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC

Lighting and Energy Efficiency

Lighting Technology. The road to smart homes. Training Systems Australia

Lighting Controls An Introduction and Review

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

FSTR- Series Microwave Motion Sensor (MSSD) Dimming Function/Detachable Version for LED Tri-proof Light & LED Batten. Introduction

Mains-related EMC-issues associated with Lighting Equipment. P.A. Beeckman PGI/Philips Innovation Services EMC Kennismarkt Oost - October 12, 2012

LED Control Solutions

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

SENSA MRE DDM MR

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

JDDT1 - Single Stage Digital Thermostat

Description of the application programme for KNX occupancy detectors version 3.1

, ,

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

IP65 High Bay Dual Sense Sensor

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Lighting & Energy Efficiency

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

Door Release Power Supply

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

Universal Fan and Light Remote Control

EBMHS (standard & slim-line PSU)

Transcription:

SHUTTLE BELL-PRESS DIMMER DATA SHEET BELL-PRESS MODELS: MINI-T-LED-125W MINI-L-LED-125W SDIM-T-LED-500W SDIM-T-LED-800W SDIM-L-LED-500W SDIM-L-LED-800W 1. Technical specifications bell-press 2 2. Dimmer maximum load rating 4 3. Wiring diagrams 5 4. Installation instructions 6 5. Operating and programming instructions 7 6. Special low voltage LED compatibility mode 9 7. Special 230VAC compatibility mode #1 10 8. Special 230VAC compatibility mode #2 10 9. Summary of dimmer settings 11 10. Certification 11 11. Contact details 12 230VAC, 50Hz, IP20 Ver 1.4 March 2017 1/12

1. TECHNICAL SPECIFICATIONS BELL-PRESS ELECTRICAL SPECIFICATIONS Normal Operating Voltage 190-253VAC, 50Hz ±5% Dimming Method Leading or Trailing Edge Minimum Operating Voltage 100VAC (3) Max. Wire Resistance (bell-press control) 50kΩ Minimum Load Power (4) 125W, 500W and 800W models Resistive 2W Inductive Not Electronic Transformer 2W (1) Maximum Load Power See table below Retain Memory After Power Failure Yes (2) Brown-Out Protection Yes High Frequency AC transient protection Yes Surge Protection Yes (in accordance with IEC61000) LOAD COMPATIBILITY AND MAXIMUM RATINGS DimmingWire Wound Model Method & Inductive Loads MINI-T-LED-125W Trailing NOT MINI-L-LED-125W Leading NOT SDIM-T-LED-500W Trailing NOT SDIM-T-LED-800W Trailing NOT SDIM-L(N)-LED-500W Leading NOT SDIM-L(N)-LED-800W Leading NOT 230VAC, Resistive & Electronic low voltage 125VA (230VAC) 0.55A rms 125VA (230VAC) 0.55A rms 500VA (240VAC) 2.1A rms 800VA (240VAC) 3.3A rms 500VA (240VAC) 2.1A rms 800VA (240VAC) 3.3A rms 230VAC & 12V LED (5)(6) YES See Shuttle LED compatibility chart Fluorescent & CFL NOT NOT NOT NOT NOT NOT SOFTWARE FEATURES Microprocessor Control Soft Start and Soft Off Bell-press Control Minimum Intensity Control Memory Yes Yes Continuous cycling Yes Yes, returns to previous dimming level when turned on, except after a power failure (2) Ver 1.4 March 2017 2/12

ENVIRONMENTAL Operating Temperature Storage Temperature Maximum Housing Temperature Relative Humidity Enclosure -5 - +45 o C -30 - +80 o C 85 o C 90% (non condensing) 125W - 36 x 36 x 12mm Plastic 500W - 42 x 42 x 13mm Black Aluminium 800W - 42 x 42 x 13mm Black Aluminium CONFORMITY EMC SANS 215, CISPR 15:2009 SABS CISPR 22:2008 Safety IEC 60669-1:2007, SANS 60669-1: 2007 IEC 60669-2-1:2009, SANS 60669-2-1:2009 Immunity SANS 61000-4-4 (2011), IEC 61000-4-4 (2011) Electrical Fast Transient / Burst Quality Management ISO 9001:2008 SABS/NRCS Approval RCC no s 1407115 & 101203 (1) Most electronic transformers require a minimum load of at least 20W, but it could be higher depending on manufacturer (2) If the dimmer was on during a power failure, it will turn on at 50% intensity when power is restored, irrespective of dimming level before the power failure. If the dimmer was off during a power failure, it will remain off when power is restored. (3) Incandescent load. Minimum operating voltage with electronic transformer is dependant on the specific transformer's specifications. Continuous operation at supply voltages below the normal operating voltage is not recommended (4) Minimum load depends on type of load (5) Only compatible with low voltage dimmable LED lamps with manufacturer approved electronic transformers (6) Please refer to Shuttle s LED compatibility chart Ver 1.4 March 2017 3/12

2. DIMMER MAXIMUM LOAD RATING Incandescent and halogen lamps normally have a unity power factor and the maximum dimmer load is then equal to the dimmer rating. However, some loads might have a lower power factor which imposes a limitation on the maximum dimmer load. The dimmer maximum load rating can be calculated as follows: Max load = (Dimmer VA rating) X (Load power factor) For example, if a 500W dimmer model is used and the load power factor is 50%, then the maximum allowable load is 250W. Please note: if the load current waveform has a high harmonic content under dimming conditions (most dimmable LED lamps) the guidelines in Shuttle s tested LED compatibility chart must be followed. Should the LED not be listed in Shuttle s chart, use the replacement GLS or halogen rating of the LED to calculate the maximum number of LED s per dimmer as per recommendations from leading European LED suppliers. For example, if a 5W LED s replacement wattage is 50W, then only 10 LED s can be connected to a 500W dimmer. MORE THAN ONE DIMMER PER WALL BOX There is no allowance in the IEC or SABS/SANS specifications for dimmers to be tested or qualified for more than one dimmer per wall box. It is however often desired to install more than one dimmer per switch box. In these cases it must be kept in mind that a dimmer does heat up the air inside a closed space and two or more dimmers in the same closed space will hence influence each other's maximum load and temperature ratings. Ideally the additional dimmers should be installed remotely (in the ceiling or roof), or the dimmers should be de-rated. There is no de-rating factor available from the international specifications, but Shuttle recommends that the maximum dimmer VA rating (or maximum load per dimmer) be de-rated by 1.15 times the number of dimmers inside the same enclosure, as follows: Dimmer VArating (calculated max load ) Dimmer reduced VA(max load)rating= 1.15 x(number of dimmers) For example, if two 500W dimmers are being installed in the same wall box, each dimmer's VA rating is de-rated to 217VA each. Similarly for three 500W dimmers, each dimmer is de-rated to 145VA. The normal dimmer maximum load for non-unity loads must however still be obeyed. Hence in the example of the three dimmers, if one load has a unity power factor, that dimmer's wattage rating is 145W and if the other two loads have a 50% power factor, each of the corresponding dimmers will have a maximum load rating of 73W. Ver 1.4 March 2017 4/12

3. WIRING DIAGRAMS SINGLE SWITCH INSTALLATION Red-LINE Red-LOAD Bell-press (L and T models) White to any Dimmer Switch Red-LINE Red-LOAD Bell-press (LN models) Black-NEUTRAL White to any Dimmer Switch Ver 1.4 March 2017 5/12

MULTIPLE SWITCH INSTALLATION Live IN Load Out Bell-press (L and T models) White wires to switch at dimmer Two terminal bell-press switch Extend white wires to remote switch 4. INSTALLATION INSTRUCTIONS Installation must be carried out by a qualified and registered electrician Installation must be carried out in accordance with the local code of practice Wire the mains connections according to the relevant wiring diagram and connect a mains rated normally open (N.O.) bell-press switch to the two white wires Never connect the white control wires to mains live, neutral or earth Install only one dimmer per wall box Internal use only Do not install or operate close to flammable materials For two or multiple way switching: connect the two white wires to the other switch(es) - NO mains live, neutral or earth should be connected to any of the switches Ver 1.4 March 2017 6/12

5. OPERATING AND PROGRAMMING INSTRUCTIONS TURNING THE LIGHT ON OR OFF Press and release the bell-press switch once to turn the dimmer (light) on or off. The dimmer will remember the last dim level (light intensity) where it was turned off and return to the same light level when turning on again. If the bell-press switch is pressed and not released when turning the dimmer on, the dimmer will turn the light on to it's previous level when it was turned off, wait for 1.5 seconds to ensure that the startup conditions are met and then start to dim until the switch is released as is described below. DIMMING UP OR DOWN When the light is on, press the bell-press switch (do not release immediately, the dimmer will turn off). The light will dim either up or down, release the switch at the desired light level. Should the dimming direction be incorrect, release the bell-press switch momentarily and press and hold again, the dim direction will be reversed. This process can be repeated continuously should a very specific light level be desired. If the bell-press switch is continuously pressed while the light is on, the light intensity will continuously cycle between minimum and maximum with a slight delay when maximum or minimum light intensity is reached (see diagram below). When the bell-press switch is released, the light level will remain at the intensity at the instance when the switch was released. Light intensity New light level when switch is released 3-4s 0.6s Time (while bell-press switch is pressed) Ver 1.4 March 2017 7/12

MEMORY AFTER POWER FAILURE The dimmer has non-volatile memory which retains it's settings during a temporary or prolonged (up to 10 years) power failure. Some operating mode information is stored in this memory (see also below), such as whether the dimmer is on or off. This enables the dimmer to mimic the behaviour of a mechanical toggle switch. Therefore if the light was off before a power failure, it will remain off when power is restored. Similarly, if the light was on before a power failure, the light will come on when power is restored again. However, to conserve energy, the light will always be restored to approximately 50% intensity, irrespective of the light level when the power failure occurred. SETTING THE MINIMUM DIM LEVEL (MINDIM T ) TO OTHER THAN FACTORY DEFAULT It is often desirable not to dim the lights to minimum that the dimmer allows. Some international dimmers are equipped with a method of adjusting the dimmer's minimum level, but this usually involves removing the switch or faceplate to adjust a mechanical screw. The Shuttle SDIM range of bell-press dimmers are however equipped with a patented simple and user friendly method of accomplishing this. Dim the light to a comfortable or desired minimum light output. Press the bell-press switch eleven (11) times fairly quickly (between 0.2 and 0.3 seconds apart). The light will then immediately go to full brightness to indicate that the programmed minimum light level is stored to permanent memory (retained after prolonged power failure). When the light is now dimmed, the light level will not go below the stored level. To ensure that the user does not accidentally set a very high light level as the minimum, the dimmer will not allow a level above approximately 35% of the maximum light level to be saved. Should the switch be pressed 11 times if the light level is above the approximate 35% limit, the dimmer will store 35% as the new minimum level. SETTING THE MINIMUM DIM LEVEL (MINDIM T ) TO LOWER THAN FACTORY DEFAULT As above, it is sometimes desirable to dim lower than the factory default as follows: dim the light to a low level and press the bell-press switch nine (9) times fairly quickly (between 0.2 and 0.3 seconds apart). The light will then immediately go to full brightness to indicate that the programmed minimum light level is stored to permanent memory (retained after prolonged power failure). When the light is now dimmed, the light level will dim lower than factory default. TIP: If the new lower than default light level is possibly a bit too low, the minimum level can still be set with the 11-click method above. SETTING THE MAXIMUM DIM LEVEL (MIAXDIM T ) It is sometime desirable not to dim the lights to the maximum that the dimmer allows. Dim the light to a comfortable or desired maximum light output. Press the bell-press switch seventeen (17) times fairly quickly (between 0.2 and 0.3 seconds apart). The light will then immediately go to minimum brightness to indicate that the programmed maximum light level is stored to permanent memory (retained after prolonged power failure). When the light is now dimmed, the light level will not go above the stored level. To ensure that the user does not accidentally set a very low light level as the maximum, the dimmer will not allow a level below approximately 35% of the minimum light level to be saved. Ver 1.4 March 2017 8/12

RESTORING THE DIMMER TO FACTORY SETTINGS If a user previously changed a setting (such as setting the dimmer minimum light level) and wishes to restore to factory default, the process is equally simple. Press the bell-press switch thirteen (13) times fairly quickly (between 0.2 and 0.3 seconds apart). The light will then immediately go to full brightness to indicate that all settings are restored to factory default and stored to permanent memory (retained after prolonged power failure). TIP: Before restoring the factory default, first dim the light down. This will make it easier to see that the light go to full brightness to indicate that the setting was restored. 6. SPECIAL LOW VOLTAGE LED COMPATIBILITY MODE Please consult Shuttle before activating this mode. Please note: this mode is only available in the trailing edge models and should NOT be used for incandescent, halogen or 230VAC dimmable LED lamps it's application is limited to dimmable LEDs with conventional electronic transformers only. Most dimmable low voltage MR16 LED lamps in combination with conventional (halogen) electronic low voltage transformers are generally compatible with trailing edge dimming technology due to the virtually implicit high power factor requirements of the transformers to operate the LED lamps. The SDIM-T-LED version of the Shuttle dimmers is thus ideally suited for this type of load which ensures 100% silent operation and eliminates the higher inrush currents associated with leading edge dimming methods, thereby ensuring very low EMI and RF, a high LED load capability and reduced stress in the LED electronic components. The factory default settings of the SDIM-T-LED are compatible with most dimmable MR16 LED's, but there could be instances where it is desirable or perhaps necessary to activate a patented MR16 LED compatibility mode on this dimmer model (refer to Shuttle compatibility chart). When in the MR16 LED compatibility mode, the dimmer will adjust the following parameters: Higher minimum light level Slower dimming at low light output With very little load, some transformers might not turn on properly, especially at low light level. In this mode, the dimmer will attempt to force trigger the electronic transformer. When in the low voltage compatibility mode, the minimum dim levels can be set as described in the previous section. Restoring the dimmer to factory default will however restore (cancel) the low voltage compatibility mode to factory default as well. ACTIVATING THE LOW VOLTAGE COMPATIBILITY MODE Irrespective of whether the light is on or off, press the bell-press switch fifteen (15) times fairly quickly (0.2-0.3 seconds apart). The light will then immediately go to full intensity to indicate that the MR16 mode is stored to permanent memory. RESTORING THE LOW VOLTAGE COMPATIBILITY MODE TO FACTORY SETTINGS Please follow the instructions for restoring the dimmer to factory default. Ver 1.4 March 2017 9/12

7. SPECIAL 230VAC COMPATIBILITY MODE #1 Please consult Shuttle before activating this mode. Some LED s have a built in digital circuit which controls the LED s minimum intensity and turn on intensity. In these cases it can be encountered that the LED turns off prematurely and only turns on at a higher intensity setting which requires trail and error setting of the dimmer's minimum intensity. To alleviate this inconvenience the trailing edge dimmer versions can be programmed for this type of LED s, as follows: ACTIVATING THE 230VAC COMPATIBILITY MODE #1 Turn the light on and press the bell-press switch five (5) times fairly quickly (0.2-0.3 seconds apart). The lamp will then immediately go to full brightness to indicate that the setting is stored to permanent memory. RESTORING THE 230VAC COMPATIBILITY MODE #1 TO FACTORY SETTINGS Please follow the instructions for restoring the dimmer to factory default. When the dimmer is set to this mode the maximum and minimum dim levels (9, 11 and 17 clicks) can be set if required, but the low voltage compatibility mode is disabled and is only accessible after resetting the dimmer to factory default. 8. SPECIAL 230VAC COMPATIBILITY MODE #2 Please consult Shuttle before activating this mode. Some LED s might encounter a very slight flicker or shimmer between 40-60% intensity. To alleviate this inconvenience the trailing edge dimmer versions can be programmed for this type of LED s, as follows: ACTIVATING THE 230VAC COMPATIBILITY MODE #2 Turn the light on and press the bell-press switch seven (7) times fairly quickly (0.2-0.3 seconds apart). The lamp will then immediately turn off and turn on again to indicate that the setting is stored to permanent memory. RESTORING THE 230VAC COMPATIBILITY MODE #2 TO FACTORY SETTINGS Please follow the instructions for restoring the dimmer to factory default (lamp will turn off and on again) When the dimmer is set to this mode the maximum and minimum dim levels (9, 11 and 17 clicks) can be set if required, but the low voltage compatibility mode and 230VAC compatibility mode #1 are disabled and are only accessible after resetting the dimmer to factory default. Ver 1.4 March 2017 10/12

9. SUMMARY OF DIMMER SETTINGS 2 x bell-presses Turn lamp on to 50% intensity, irrespective of previous state mostly for use with Shuttle Master Zone Controller (MZC) 5 x bell-presses (setting available for Trailing Edge only please refer to data sheet) Compatibility mode #1 for LED s with a digital control of turn off and turn on intensities 7 x bell-presses (setting available for Trailing Edge only please refer to data sheet) Compatibility mode #2 for LED s which might encounter a very slight flicker or shimmer between 40-60% intensity 9 x bell-presses (*1) Set the minimum dim level to lower than factory default 11 x bell-presses (*2) Set the minimum dim level to a user selected level 13 x bell-presses (*1) Reset all settings to factory default 15 x bell-presses (setting available for Trailing Edge only *1) Compatibility mode for certain electronic transformer/led combinations 17 x bell-presses (setting available for Trailing Edge only *3) Set the maximum dim level to a user selected level (*1) Tip first dim to a low intensity. If the dimmer accepts the setting, the lamps will go to full intensity. (*2) If the dimmer accepts the setting, the lamps will go to full intensity (*3) If the dimmer accepts the setting, the lamps will go to minimum intensity 10. CERTIFICATION Please refer to SABS/NRCS RCC Certificates Ver 1.4 March 2017 11/12

11. CONTACT DETAILS Shuttle Lighting Control Systems (Pty) Ltd Head Office - Cape Town Unit A8 Waverley Court 7 Kotzee Road Mowbray 7700 P O Box 13180 Mowbray 7705 (021) 448 8229 (tel) (021) 448 8228 (fax) Contact Person: Reg Smith Mobile:083-680-5761 email: rsmith@shuttlelighting.com Technical Office - Pretoria 793A Platrand Street Faerie Glen Pretoria 0043 P O Box 38134 Fearie Glen 0043 082 465 2299 (tel) 086 6595041 (fax) Contact Person: Marthinus Smit email: mcsmit@shuttlelighting.com Sales sales@shuttlelighting.com Ver 1.4 March 2017 12/12