The Baked Food Company

Similar documents
The following report is prepared and published by:

GAS RACK OVENS WITH ELECTRONIC OVEN CONTROL

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

Installation Instructions Wall Ovens

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing

Packaged Gas/Electric

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

DIRECTIVE NO: D-B

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

HEATEC TEC-NOTE. Operation and maintenance Heatec thermal fl uid heaters industrial series IMPOPRTANT NOTICE! CONTENTS. Publication No.

KEES, INC. Installation & Maintenance Manual DFG Series Direct Gas Fired Make-up Air Heaters. Table of Contents FOR YOUR SAFETY.

User s Information Manual

SECTION FAN COIL UNITS

IMPORTANT INSTRUCTIONS

OPERATING AND MAINTENANCE MANUAL

Preventative Maintenance Tables

Diocese of Cleveland Facilities Services Corporation

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

Model RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL

NMG NOZZLE MIX GAS BURNERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

User s Information Manual

Direct Fired Heater Model AD Specification

Food Service Technology Center

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

4.6 Advanced Propane Appliance Service and Troubleshooting Performance-Based Skills Assessment 2019

PBG PACKAGED GAS BURNER

INFRA-RED BURNERS DESCRIPTION USES MODEL: 3207

Indirect gas-fired air heater

Conveyor and Batch Reflow Ovens

Specifications of V-Line burners

Corn Flame Energy Corn Stove Model 3000

INFRA-RED BURNERS DESCRIPTION USES MODEL: 3207

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS

Jr. Tech (JT-1, 2, 3) Knowledge Areas

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

Energy saving and better heat control.

COMPETITIVE INITIATIVE POWDER COATING SPRAY SYSTEM MINES TECHNICAL SPECIFICATION

Gas-Fired Indoor and Outdoor Duct Furnaces

Operator s Manual. 68 Inch Digital Conveyor Pizza Ovens

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

CMO32 CMO50 DOMESTIC WATER HEATER OIL-FIRED. Models: CMO32 CMO50

SECTION WATER-TUBE BOILERS

Interrupted Ignition Series Oil Primary Control

User s Information Manual

CONTENTS. B. System Design and Performance Requirements

City of Duluth Festival Center 04/25

The information presented in this manual applies to the 27" negative pressure dryer, both electric and gas models.

V SERIES HDR GAS RANGES

SA Series Start up Report

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Electric Heat Inspection Form Revised September 2012

DOMESTIC WATER HEATER OIL FIRED

INDITHERM. Low temperature gas burners

7.0 Applying Basic Electricity Principles to Service Propane Appliances Skill Evaluation Packet (Updated 11/2012)

Indirect Gas-Fired Make-Up Air

OPERATION, MAINTENANCE AND PARTS MANUAL

Installation & Operation Guide

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

XLT Oven & AVI Hood. Technical/Rough-In Specifications for Gas & Electric Ovens & Hoods

USER'S MANUAL PGE Single Package Rooftop

TANKLESS WATER HEATER HEATING SOLUTIONS

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

Installation & Operation Guide Industrial Non Re-circulating Direct-Fired Heaters Horizontal / Vertical and Single / Twin Blowers

Installation Instructions

MANUAL INSTALLATION. Fan Column. v200 Issue Date: 01/18/ Price Industries Limited. All rights reserved.

M2 Series Startup Form

Power Flame Incorporated

Type CG Series Forced Draft Gas Burner

ELECTRIC FIREPLACE INSERT MODEL EF-BLT10 OWNER S MANUAL

NR-20DU. Keep this manual near this remote controller for future reference whenever maintenance or service is required.

Burners Flares Incinerators Vapor Combustion

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Field Start-Up Sheet Direct Fired Gas Equipment

O PE R AT I ON HO851G REVOLVING TRAY OVEN. MODEL HO851G GAS ML Pan ML Pan ML Pan ML Pan

Electrical Preventive Maintenance (EPM) Program

The Ultimate in Pizza Baking Variable speed Black granite stone conveyor belt Turbo-Flex Airflow System

Installation Instructions

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

USER S INFORMATION MANUAL (2,4)SG13B

Installation & Maintenance Instructions

Instruction Manual for Electric Ovens OO757X OO986X

LGA/LGC036, 042, 048, 060, 072 (3, 3-1/2, 4, 5, and 6 TONS) LGA/LGC090, 102, 120, 150, (7-1/2, 8-1/2, 10, and 12-1/2 TONS)

READ AND SAVE THESE INSTRUCTIONS

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

WD7664 / WD7663 Maxon Burner Ellis Whisper Dryer Installation & Start UP

en Hydronic Surface Heater E 1100 REPAIR MANUAL

Direct Gas-Fired Make-Up Air

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

TYCO VALVES & CONTROL Dual Painting System

NFPA 86 Commitee Inputs Page 1 of 45

SECTION ENCLOSED CONTROLLERS

Transcription:

The following report is prepared and published by: 7 CORPORATE BLVD. SINKING SPRING, PA 19608 USA T: 610-678-5890 F: 610-693-6262 www.readingthermal.com The Baked Food Company Leesport, PA. USA OVEN SAFETY INSPECTION REPORT September 18, 2012 SAMPLE REPORT The following report is prepared for: Al Gebra, Senior Process Engineer The Baked Food Company 123 Industrial Boulevard Leesport, PA 90210 610-867-5309 (o) 610-867-1234 (c)

TABLE OF CONTENTS Summary 3 Safety Inspection Unsatisfactory Items 3 General Line Observations 3 Oven Specifications Line #5 4 Benchmark Profiles Line #5 5 Equipment Inspection Checklists Line #5 9 Appendix 21 Oven Safety Inspection Program 21 Sample Control Panel Label 22 Baked Food (Leesport, PA) Oven Safety Inspection Report Line 5 2 of 22

SUMMARY At the request of The Baked Food Company, Reading Thermal conducted an oven safety inspection on Line 5 at the Leesport, PA plant. The inspection was conducted on September 18, 2012. The inspection team consisted of: Reading Thermal The Baked Food Company Josh Dennis, Thermal Process Engineer Email: josh.dennis@readingthermal.com Ronald D. Rench, Plant Maintenance Email: ron.rench@totallybaked.com Calvin Culus, Project Engineer Email: cal.culus@totallybaked.com Benchmark profiles were collected on Line 5 to serve as a future point of reference. Safety Inspection Unsatisfactory Items Line # 5 Oven Checklist # N/A Description See Zone Checklists Zone Checklist # Zone # Description 1 All Zones No Normally Open vent between safety valve and blocking valve 8 2,3,5 Gas pressure gauge appears stuck 16 3,4,5 Combustion blower air flow switch did not function properly during test 19 All zones Exhaust blower air flow switch did not function properly during test General Line Observations Line #5 1. Several pressure gauges missing lens covers. 2. Digital readout on High-temp switch blank zone 1. 3. Vent line connected to regulator pinched shut zone 4. 4. Ignition transformer loosely installed - hanging zone 5. Baked Food (Leesport, PA) Oven Safety Inspection Report Line 5 3 of 22

OVEN SPECIFICATIONS LINE #5 Oven Inspected: Line #5 Plant Name Baked Food (Leesport, PA) Oven Line ID Line 5 Oven Type Indirect Gas Fired / Convection Electrical Print # Not Available for Inspection Product Scrapple Pie Shells Oven Dimensions 100 wide x 92 long Oven Manufacturer XYZ Equipment # of Oven Zones 5 Conveyor Type Stainless Steel Flat Wire, Open Weave Conveyor Width 100 Zone Lengths Z1=13.1ft, Z2=13.1ft, Z3=19.7ft Z4=19.7ft, Z5=26.5ft Oven Description The oven is comprised of 5 independent baking zones equipped with Maxon EB-2 style burners with an overall rated nominal capacity of 5 million btus. The burner valve train consists of a single stringed pipe gas supply system factory mutual train. The oven band contains 1 x1 openings in the belt. The band is divided into left and right sides with 45 x 45 trays traveling side by side through the length of the oven. The two pans travel through the oven on top of the band. Each tray contains 49, 5 diameter circular depressions arranged in a 7 x 7 grid. Each recess contains dough that is baked into Scrapple Pie shells. An air-to-air heat exchanger is attached to the top of each zone in a penthouse to capture and reuse some of the exhaust heat. Each zone has an exhaust fan and fire damper. Baked Food (Leesport, PA) Oven Safety Inspection Report Line 5 4 of 22

BENCHMARK PROFILES LINE #5 Oven Production Settings Oven Line 5 was the first line that data was collected from at the plant. The oven was running at normal production settings and had been running for several hours prior to when the profiles were collected at full product load. A continuous flow of 2 trays, side by side, traveled through the oven. The T/B damper settings were 20% for zone 1, 20% zone 2, 35% zone 3, 40% zone 4, and 45% zone 5. After checking for clearance of the SCORPION equipment, a total of 2 passes were performed with the first pass collecting data from the R&D sensor and the second pass collecting humidity data. The R&D sensor collected air velocity, lower air temperature through oven band, upper air temperature, and heat flux. The equipment traveled on the right side of the oven in the direction of travel to allow proper feed and removal of the equipment. Profiles were not collected on the left-hand path where the trays traveling down the left side of the oven would pass through. Bake Time 3 min: 6 sec Belt Speed 30 fpm SCORPION Profiles Date Time Plot Type File Name Description 9/18/2012 13:16 Air Velocity Baked Food (Leesport, PA) Line 5 AV Single point measurement through the process 9/18/2012 13:16 Temperature Upper 9/18/2012 13:16 Temperature Lower 9/18/2012 13:16 Heat Flux 9/18/2012 13:26 Humidity Baked Food (Leesport, PA) Line 5 T up Baked Food (Leesport, PA) Line 5 T low Baked Food (Leesport, PA) Line 5 HF Baked Food (Leesport, PA) Line 5 HU Single point measurement through the process Single point measurement through the process Single point measurement through the process Single point measurement through the process Baked Food (Leesport, PA) Oven Safety Inspection Report Line 5 5 of 22

Oven Benchmark Profile Charts Line #5 Chart 7 Upper Air Temperature Line 5 Upper air temperature appears normal for this type of oven. Chart 8 Lower Air Temperature Line 5 Lower air temperature is normal for this oven type. Baked Food (Leesport, PA) Oven Safety Inspection Report Line 5 6 of 22

Oven Benchmark Profile Charts Line #5 Chart 9 Air flow Line 5 The Air Velocity profile appears OK for this type of oven. Explanations for dips in Air velocity may be attributed to the Penthouse Effect which occurs in areas underneath a penthouse where there can be no air distribution. Chart 10 Humidity Line 5 GREEN line is humidity mass ratio It is abnormal for humidity to rise at the end of the baking process. The oven should be examined and product moisture should be checked to see if too much moisture is present. Exhaust settings also contribute to increased humidity if air is not being exhausted at a proper rate. Baked Food (Leesport, PA) Oven Safety Inspection Report Line 5 7 of 22

Oven Benchmark Profile Charts Line #5 Chart 12 Total heat seen by product Line 5 This is a typical heat flux profile for a convective oven as most of the heat present is convective. The total heat seen by the product is around 140 Btu/ft 2 with the type of heat split 81% convective and 19% radiant. Baked Food (Leesport, PA) Oven Safety Inspection Report Line 5 8 of 22

EQUIPMENT INSPECTION CHECKLIST: OVEN Oven Overall: SATISFACTORY YES NO N/A 1. Are the combustion blowers filters clean? X 2. Are all moving parts properly guarded? X 3. Does the oven have deflagration vents (explosion panels)? X 4. Is there a main gas pressure regulator ( )? X 5. Does the oven have safety valve and blocking valve with N.O. vent between? X 6. Do the lubricated shutoff valves operate and are the handles in place? X 7. Does the Maxon valve operate properly? X 8. Does the safety valve proving switch (VPS) operate properly? X 9. Is the front of the oven electrical panel at least 4' from any another electrical panel and at least 3' from any other obstructions? Does the door open freely? 10. Are all push buttons, selector switches, and pilot lights properly identified? X 11. Are all control fuses and circuit breakers in place? X 12. Are all motor starters and contactors in place? X 13. Are all motor overload heaters in place? X X Oven Pre-Heat Section: N/A No Preheat 14. Does the ignition transformer operate properly? X 15. Is the igniter adjustment operable? X 16. Does the flame monitoring system operate properly? X 17. Are the warning alarms operating properly (horns, lights, etc.)? X 18. Does the safety valve proving switch (VPS) operate properly? X 19. Does the Maxon valve operate properly? X 20. Is there a Zero pressure regulator [Y/N] or a Zone pressure regulator [Y/N]? X 21. Does the combustion blower start before purge is complete? X 22. Are the combustion blower filters clean? X 23. Does the combustion blower air flow switch operate? X 24. Is the condition of combustion air supply tubing satisfactory? X 25. Does the combustion blower auxiliary contact operate correctly? X 26. Does the preheat chamber high temp. switch operate properly? Setting ( F) X 27. Purge Timer: minutes required by manufacturer ( ) X 28. Purge Timer: minutes set ( ), minutes actual ( ) X Baked Food (Leesport, PA) Oven Safety Inspection Report Line 5 9 of 22

EQUIPMENT INSPECTION CHECKLIST: OVEN Oven Overall Comments: NOTE - Several pressure gauges missing lens covers. Baked Food (Leesport, PA) Oven Safety Inspection Report Line 5 10 of 22

EQUIPMENT INSPECTION CHECK LIST: ZONE # 1 Zone Specific: SATISFACTORY YES NO N/A 1. Does the zone have a safety valve and blocking valve with N.O. vent between? X 2. Do the lubricated shutoff valves operate properly and are handles in place? X 3. Is the gas Pressure regulator ( " W.C.) present and operating correctly? X 4. Is the low gas pressure switch ( 2" W.C.) present and operating correctly? X 5. Is the high gas pressure switch ( 16" W.C.) present and operating correctly? X 6. Does the safety valve proving switch (VPS) operate properly? X 7. Is the condition of gas supply tubing satisfactory. X 8. Are all the pressure gauges operating and in good condition? X 9. Purge Timer: minutes required by manufacturer ( 4 ) X 10. Purge Timer: minutes set ( ), minutes actual ( ) X* 11. Does the Maxon valve operate properly? X 12. Does the purge damper open before purge is completed? X 13. Does the purge damper close when purge is complete? X 14. Does the combustion blower start before purge is completed? X 15. Are the combustion blowers filters clean? X 16. Does the combustion blower air flow switch operate properly? X 17. Is the condition of combustion air supply tubing satisfactory? X 18. Does the exhaust blower start before purge is complete? X 19. Does the exhaust blower air flow switch operate properly? X 20. Does the exhaust damper limit switch operate properly? X 21. Does the recirculation blower air flow switch operate properly? X 22. Do the gas solenoid valves operate correctly? X 23. Does the exhaust blower auxiliary contact operate properly? X 24. Does the combustion blower auxiliary contact operate correctly? X 25. Does the recirculation blower auxiliary contact operate properly? X 26. Does the ignition transformer operate properly? X 27. Is the igniter adjustment operating correctly? X 28. Does the flame monitoring system operate as designed? X 29. Are the warning alarms operating (horn, lights, etc.) correctly? X 30. Does the top burner chamber high temperature switch work? Setting ( 580 F) X* 31. Does the bottom burner chamber high temperature switch work? Setting ( F) X Baked Food (Leesport, PA) Oven Safety Inspection Report Line 5 11 of 22

EQUIPMENT INSPECTION CHECK LIST: ZONE #1 Zone Specific Comments: #1 No N.O. vent between safety valve and blocking valve. #10 NOTE: Purge timer part of flame monitoring system. #19 Exhaust blower air pressure switch not functioning. #30 NOTE: Digital readout on High-temp switch inoperative. Baked Food (Leesport, PA) Oven Safety Inspection Report Line 5 12 of 22

EQUIPMENT INSPECTION CHECK LIST: ZONE # 2 Zone Specific: SATISFACTORY YES NO N/A 1. Does the zone have a safety valve and blocking valve with N.O. vent between? X 2. Do the lubricated shutoff valves operate properly and are handles in place? X 3. Is the gas Pressure regulator ( " W.C.) present and operating correctly? X 4. Is the low gas pressure switch ( 2" W.C.) present and operating correctly? X 5. Is the high gas pressure switch ( 14" W.C.) present and operating correctly? X 6. Does the safety valve proving switch (VPS) operate properly? X 7. Is the condition of gas supply tubing satisfactory. X 8. Are all the pressure gauges operating and in good condition? X 9. Purge Timer: minutes required by manufacturer ( 4 ) X 10. Purge Timer: minutes set ( ), minutes actual ( ) X* 11. Does the Maxon valve operate properly? X 12. Does the purge damper open before purge is completed? X 13. Does the purge damper close when purge is complete? X 14. Does the combustion blower start before purge is completed? X 15. Are the combustion blowers filters clean? X 16. Does the combustion blower air flow switch operate properly? X 17. Is the condition of combustion air supply tubing satisfactory? X 18. Does the exhaust blower start before purge is complete? X 19. Does the exhaust blower air flow switch operate properly? X 20. Does the exhaust damper limit switch operate properly? X 21. Does the recirculation blower air flow switch operate properly? X 22. Do the gas solenoid valves operate correctly? X 23. Does the exhaust blower auxiliary contact operate properly? X 24. Does the combustion blower auxiliary contact operate correctly? X 25. Does the recirculation blower auxiliary contact operate properly? X 26. Does the ignition transformer operate properly? X 27. Is the igniter adjustment operating correctly? X 28. Does the flame monitoring system operate as designed? X 29. Are the warning alarms operating (horn, lights, etc.) correctly? X 30. Does the top burner chamber high temperature switch work? Setting ( 580 F) X 31. Does the bottom burner chamber high temperature switch work? Setting ( F) X Baked Food (Leesport, PA) Oven Safety Inspection Report Line 5 13 of 22

EQUIPMENT INSPECTION CHECK LIST: ZONE #2 Zone Specific Comments: #1 No N.O. vent between safety valve and blocking valve. #8 Gas pressure gauge appears stuck. #10 NOTE: Purge timer part of flame monitoring system. #19 Exhaust blower air pressure switch not functioning. Baked Food (Leesport, PA) Oven Safety Inspection Report Line 5 14 of 22

EQUIPMENT INSPECTION CHECK LIST: ZONE # 3 Zone Specific: SATISFACTORY YES NO N/A 1. Does the zone have a safety valve and blocking valve with N.O. vent between? X 2. Do the lubricated shutoff valves operate properly and are handles in place? X 3. Is the gas Pressure regulator ( " W.C.) present and operating correctly? X 4. Is the low gas pressure switch ( 2" W.C.) present and operating correctly? X 5. Is the high gas pressure switch ( 14" W.C.) present and operating correctly? X 6. Does the safety valve proving switch (VPS) operate properly? X 7. Is the condition of gas supply tubing satisfactory. X 8. Are all the pressure gauges operating and in good condition? X 9. Purge Timer: minutes required by manufacturer ( 4 ) X 10. Purge Timer: minutes set ( ), minutes actual ( ) X* 11. Does the Maxon valve operate properly? X 12. Does the purge damper open before purge is completed? X 13. Does the purge damper close when purge is complete? X 14. Does the combustion blower start before purge is completed? X 15. Are the combustion blowers filters clean? X 16. Does the combustion blower air flow switch operate properly? X 17. Is the condition of combustion air supply tubing satisfactory? X 18. Does the exhaust blower start before purge is complete? X 19. Does the exhaust blower air flow switch operate properly? X 20. Does the exhaust damper limit switch operate properly? X 21. Does the recirculation blower air flow switch operate properly? X 22. Do the gas solenoid valves operate correctly? X 23. Does the exhaust blower auxiliary contact operate properly? X 24. Does the combustion blower auxiliary contact operate correctly? X 25. Does the recirculation blower auxiliary contact operate properly? X 26. Does the ignition transformer operate properly? X 27. Is the igniter adjustment operating correctly? X 28. Does the flame monitoring system operate as designed? X 29. Are the warning alarms operating (horn, lights, etc.) correctly? X 30. Does the top burner chamber high temperature switch work? Setting ( 580 F) X 31. Does the bottom burner chamber high temperature switch work? Setting ( F) X Baked Food (Leesport, PA) Oven Safety Inspection Report Line 5 15 of 22

EQUIPMENT INSPECTION CHECK LIST: ZONE #3 Zone Specific Comments: #1 No N.O. vent between safety valve and blocking valve. #8 Gas pressure gauge appears stuck. #10 NOTE: Purge timer part of flame monitoring system. #16 - Combustion blower air switch did not function correctly during check. #19 Exhaust blower air pressure switch not functioning. NOTE Combustion switch cover missing. Baked Food (Leesport, PA) Oven Safety Inspection Report Line 5 16 of 22

EQUIPMENT INSPECTION CHECK LIST: ZONE # 4 Zone Specific: SATISFACTORY YES NO N/A 1. Does the zone have a safety valve and blocking valve with N.O. vent between? X 2. Do the lubricated shutoff valves operate properly and are handles in place? X 3. Is the gas Pressure regulator ( " W.C.) present and operating correctly? X 4. Is the low gas pressure switch ( 4" W.C.) present and operating correctly? X 5. Is the high gas pressure switch ( 16" W.C.) present and operating correctly? X 6. Does the safety valve proving switch (VPS) operate properly? X 7. Is the condition of gas supply tubing satisfactory. X 8. Are all the pressure gauges operating and in good condition? X 9. Purge Timer: minutes required by manufacturer ( 4 ) X 10. Purge Timer: minutes set ( ), minutes actual ( ) X* 11. Does the Maxon valve operate properly? X 12. Does the purge damper open before purge is completed? X 13. Does the purge damper close when purge is complete? X 14. Does the combustion blower start before purge is completed? X 15. Are the combustion blowers filters clean? X 16. Does the combustion blower air flow switch operate properly? X 17. Is the condition of combustion air supply tubing satisfactory? X 18. Does the exhaust blower start before purge is complete? X 19. Does the exhaust blower air flow switch operate properly? X 20. Does the exhaust damper limit switch operate properly? X 21. Does the recirculation blower air flow switch operate properly? X 22. Do the gas solenoid valves operate correctly? X 23. Does the exhaust blower auxiliary contact operate properly? X 24. Does the combustion blower auxiliary contact operate correctly? X 25. Does the recirculation blower auxiliary contact operate properly? X 26. Does the ignition transformer operate properly? X 27. Is the igniter adjustment operating correctly? X 28. Does the flame monitoring system operate as designed? X 29. Are the warning alarms operating (horn, lights, etc.) correctly? X 30. Does the top burner chamber high temperature switch work? Setting ( 580 F) X 31. Does the bottom burner chamber high temperature switch work? Setting ( F) X Baked Food (Leesport, PA) Oven Safety Inspection Report Line 5 17 of 22

EQUIPMENT INSPECTION CHECK LIST: ZONE # 4 Zone Specific Comments: #1 No N.O. vent between safety valve and blocking valve. #10 NOTE: Purge timer part of flame monitoring system. #16 - Combustion blower air switch did not function correctly during check. #19 Exhaust blower air pressure switch not functioning. NOTE Vent line connected to regulator pinched closed. Baked Food (Leesport, PA) Oven Safety Inspection Report Line 5 18 of 22

EQUIPMENT INSPECTION CHECK LIST: ZONE # 5 Zone Specific: SATISFACTORY YES NO N/A 1. Does the zone have a safety valve and blocking valve with N.O. vent between? X 2. Do the lubricated shutoff valves operate properly and are handles in place? X 3. Is the gas Pressure regulator ( " W.C.) present and operating correctly? X 4. Is the low gas pressure switch ( 4" W.C.) present and operating correctly? X 5. Is the high gas pressure switch ( 16" W.C.) present and operating correctly? X 6. Does the safety valve proving switch (VPS) operate properly? X 7. Is the condition of gas supply tubing satisfactory. X 8. Are all the pressure gauges operating and in good condition? X 9. Purge Timer: minutes required by manufacturer ( 4 ) X 10. Purge Timer: minutes set ( ), minutes actual ( ) X* 11. Does the Maxon valve operate properly? X 12. Does the purge damper open before purge is completed? X 13. Does the purge damper close when purge is complete? X 14. Does the combustion blower start before purge is completed? X 15. Are the combustion blowers filters clean? X 16. Does the combustion blower air flow switch operate properly? X 17. Is the condition of combustion air supply tubing satisfactory? X 18. Does the exhaust blower start before purge is complete? X 19. Does the exhaust blower air flow switch operate properly? X 20. Does the exhaust damper limit switch operate properly? X 21. Does the recirculation blower air flow switch operate properly? X 22. Do the gas solenoid valves operate correctly? X 23. Does the exhaust blower auxiliary contact operate properly? X 24. Does the combustion blower auxiliary contact operate correctly? X 25. Does the recirculation blower auxiliary contact operate properly? X 26. Does the ignition transformer operate properly? X 27. Is the igniter adjustment operating correctly? X 28. Does the flame monitoring system operate as designed? X 29. Are the warning alarms operating (horn, lights, etc.) correctly? X 30. Does the top burner chamber high temperature switch work? Setting ( 580 F) X 31. Does the bottom burner chamber high temperature switch work? Setting ( F) X Baked Food (Leesport, PA) Oven Safety Inspection Report Line 5 19 of 22

EQUIPMENT INSPECTION CHECK LIST: ZONE # 5 Zone Specific Comments: #1 No N.O. vent between safety valve and blocking valve. #8 Gas pressure gauge appear stuck. #10 NOTE: Purge timer part of flame monitoring system. #16 - Combustion blower air switch did not function correctly during check. #19 Exhaust blower air pressure switch not functioning. NOTE Ignition transformer loosely installed. Baked Food (Leesport, PA) Oven Safety Inspection Report Line 5 20 of 22

APPENDIX OVEN SAFETY INSPECTION PROGRAM Reading Thermal performs oven safety inspections to help customers comply with regulations adopted by OSHA as set forth in Standard 29 CFR Bakery Equipment 1910.263(L) (9) (ii). All safety devices on ovens shall be inspected at intervals of not less than twice a month by an especially appointed, properly instructed bakery employee, and not less than once a year by representatives of the oven manufacturers. Reading Thermal is qualified to perform oven safety inspections based on numerous OSHA standard interpretation letters. For example, one letter states, OSHA feels that such inspections may be accomplished by qualified representatives of any oven manufacturer who are knowledgeable of the various safety considerations and who by training and experience are capable of verifying the safe operational characteristics of the equipment. All safety devices on the oven are checked against Reading Thermal s multi-point Equipment Inspection Check List (included in this report). The customer must provide the electrical control diagrams for the oven and one maintenance person familiar with the equipment and specific functions of the various controls. This person should be from the mechanical or electrical department and skilled in reading the electrical control diagrams. It is beneficial to the customer if this person is the same person who performs the biweekly inspections. The diagrams and personnel must be available during the entire inspection procedure. Reading Thermal will perform optional benchmark profiling of the customers oven using the state-ofthe-art SCORPION system. Benchmark profiles of Temperature, Air Velocity, Heat Flux and Humidity are included. Profiles should be collected with oven at typical operating temperature and product load. Reading Thermal provides a detailed Oven Safety Inspection Report to be filed with customer safety records. A duplicate backup copy will be kept on file at Reading Thermal. The report contains the inspection results and oven benchmark profiles. Reading Thermal Liability: RT s liability for the conduct of this inspection shall be limited to return of the contract price for conducting the inspection. In no event shall RT be liable for damages, whether in contract or tort, for injury to the person or property arising out of any failure or malfunction of the Equipment, unless caused solely by RT s negligence performing its obligations under the Inspection Agreement. Baked Food (Leesport, PA) Oven Safety Inspection Report Line 5 21 of 22

CONTROL PANEL LABEL Upon completion of inspection this label will be applied to the oven control panel: Baked Food (Leesport, PA) Oven Safety Inspection Report Line 5 22 of 22