DTG130-45/65/90/115 Eco.NOx Plus

Similar documents
WHE 2.24 / WHE 2.24 FF

Low temperature gas boiler DTG 330 S. User Guide

DTG Eco / V130

DTG X.. N. Low temperature gas furnace. Instructions for use. English 14/11/2005

Gas-fired boilers DTG 230. User Guide D

Range GT GTU C GT 220

Vivadens. Wall-hung gas condensing boilers MCR 24/28 BIC. User Guide B

SOLNEO SGC 24 SOL. User Guide. Gas fired condensing boiler C

Wall-hung gas boilers. Instructions for use. English 31/08/05

Oil-fired condensing boiler GTU C 330. User Guide B

Wood-burning boiler CBB. User Guide E

Gas fired condensing boiler C 230 ECO. User Guide

MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI

MCR-P 24 MCR-P 24/28 MI MCR-P 30/35 MI MCR-P 34/39 MI

BSC...E - BSP...E - BESC...E

Gas fired condensing boiler C 230 ECO. User Guide C

Domestic hot water tank SR130. Installation, User and Service Manual

C 310 ECO - C 610 ECO

TWH 200E TWH 300E TWH 300EH

User Guide. Promax SL Condensing Central Heating Boiler

User Guide. Platinum Combi Gas Fired Wall Mounted Condensing Combination Boiler

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO

User Guide. Main Eco Elite Combi Condensing Central Heating Boiler

User Guide. Assure Heat Condensing Central Heating Boiler

Operating instructions

E-COMBI EVO E-SYSTEM EVO

Remeha. Fuel oil/gas boilers P 320. Installation and Service Manual

User Guide. Duo-tec Combi LPG. Gas Fired Wall Mounted Condensing Combination Boiler

USERS MANUAL FOR GAS BOILERS

Operating instructions

Operating instructions

Remeha. Fuel oil/gas boilers P 420. Installation and Service Manual

Product Information as required by EU regulations No 811/2013 and No 813/2013

User Guide. Gold Combi Condensing Combination Boiler

Operating instructions

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

User Guide. EcoBlue System Gas Fired Wall Mounted Condensing System Boiler

Operating instructions

User Guide Combi. Condensing Combination Boiler

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

Operating instructions

VIESMANN. Operating instructions VITODENS 111-W. for the system user

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

INSTRUCTION FOR THE USER THC V E OIL BLU

VIESMANN. Operating instructions VITODENS 100-W. for the system user

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB

User Guide. Promax Store 24. Condensing Boiler with Integrated Hot Water Storage

E-Combi One E-System ONE

INSTALLATION AND OPERATING INSTRUCTIONS KLIMA

COMMISSION REGULATION (EU) No /.. of XXX

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM OD (FOR EXTERNAL USE)

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

Installer manual ELK 213 Immersion heater

ir-range 8G /03.15 Changes reserved.

>> >> >> High technology with oil. High performance modulating burner Compact boiler design. Compatible with renewable energies. Sustainable Comfort

PART I ENERGY EFFICIENCY ACQUIS / DELEGATED REGULATION (EU) 811/2013

Draft COMMUNICATION FROM THE COMMISSION

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

USERS GUIDE 24, 30. For installation guide see reverse of book

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM

atmocraft VK 654/9-1654/9 DE/AT/GB/CZ/SK/HU/PL/HR/SI/SCG

User s Information Manual

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

USERS GUIDE. LOGIC+ Combi 24, 30, 35

User s Information Manual

CALORA TOWER GAS 15S EX CALORA TOWER GAS 25S EX CALORA TOWER GAS 35S EX

ecotec pro Operating instructions Operating instructions For the operator GB, IE Gas-fired wall-hung high-efficiency boiler

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

MIT-II/E - MIT-II/H MIT/EP - MIT/HP QUADROPAC DUP 500

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

Operating Instructions

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No.

Control panel B - FM126 B2 - FM159. Installation and Service Manual

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

FLOOR STANDING GAS CONDENSING BOILERS CONDITION OF USE CLASSIFICATION

USER MANUAL ACQUAHOME 32 B BLU

Official Journal of the European Union L 239/1. (Non-legislative acts) REGULATIONS

User and maintenance manual

USER GUIDE LOGIC HEAT H

Read installation manual prior to installation of this appliance! Read user manual before putting this unit in operation!

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

User Guide. EcoBlue Advance Heat Gas Fired Wall Mounted Condensing Boiler

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

CALDAIA MURALE A GAS A CONDENSAZIONE

INSTALLATION AND MANINTENANCE INSTRUCTIONS

DANESMOOR FRONT SERVICE (FS) 12-18, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

USER'S INFORMATION MANUAL

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

Logic+ Combi

General safety precautions English

Grant Vortex Pro Boiler House Range 26/36, 36/46, 46/58 and 58/70

GB24 & GB30. User Manual

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

User Manual for model

condens Instructions for Use Betacom 2 24 G.C. No Betacom 2 28 G.C. No

UBGHFF60W 60cm Gas on Glass Gas Hob

Transcription:

ELIDENS Gas fired condensing boiler DTG130-45/65/90/115 Eco.NOx Plus en User Guide 300005222-03

Contents 1 Safety instructions.......................................................................3 1.1 General safety instructions.................................................................................3 1.1.1 Fire hazard.......................................................................................3 1.1.2 Risk of intoxication.................................................................................3 1.1.3 Risk of being burnt.................................................................................3 1.1.4 Risk of damage...................................................................................3 1.2 Recommendations.......................................................................................4 1.3 Ventilation..............................................................................................4 1.3.1 Chimney versions..................................................................................4 1.3.2 Forced flue versions................................................................................4 1.4 Maintenance............................................................................................4 1.5 Adapting to another gas type...............................................................................4 1.6 Liabilities...............................................................................................5 1.6.1 Manufacturer's liability..............................................................................5 1.6.2 Installer's liability..................................................................................5 1.6.3 User's liability.....................................................................................5 2 About this manual........................................................................5 2.1 Symbols used in the manual...............................................................................5 2.2 Abbreviations...........................................................................................5 3 Description..............................................................................6 3.1 Boilers.................................................................................................6 3.2 Control panel...........................................................................................7 3.2.1 Electromechanical components.......................................................................7 3.2.2 Display..........................................................................................7 3.2.3 Keys accessible when the flap is closed................................................................8 3.2.4 Keys accessible when the flap is open.................................................................8 4 Energy savings..........................................................................9 5 Commissioning..........................................................................9 6 Switching off the boiler....................................................................9 7 Troubleshooting........................................................................10 8 Alarm messages........................................................................10 9 Appendix - Information on the Ecodesign and Energy Labelling Directives........................12 German instructions reference 300003110 available on request. 2 DTG130-45/65/90/115 Eco.NOx Plus 20/01/2017-300005222-03

1 Safety instructions Danger This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. Any operation on the installation must be performed by a qualified technician respecting professional regulations and in accordance with this document. Before any work, switch off the mains supply to the appliance. Protect the installation against any unwanted restarts. 1.1 General safety instructions 1.1.1 Fire hazard Do not stock products of an inflammable nature close to the appliance. If you smell gas, do not use a naked flame, do not smoke, do not operate electrical contacts or switches (doorbell, lights, motor, lift, etc.). 1.1.2 Risk of intoxication Do not obstruct the air inlets in the room (even partially). 1.1.3 Risk of being burnt Avoid direct contact with the flame viewport. 1.Shut off the gas supply 2.Open the windows 3.Extinguish all flames 4.Evacuate the premises 5.Contact a qualified professional 6.Inform the gas supplier If you smell flue gases 1. Switch the appliance off 2. Open the windows 3. Evacuate the premises 4. Contact a qualified professional Depending on the settings of the appliance: - The temperature of the flue gas conduits may exceed 60 C - The temperature of the radiators may reach 95 C - The temperature of the domestic hot water may reach 65 C 1.1.4 Risk of damage Do not stock chloride or fluoride compounds close to the appliance. Install the appliance in frost-free premises. Do not neglect to service the appliance: Contact a qualified professional or take out a maintenance contract for the annual servicing of the appliance. 20/01/2017-300005222-03 DTG130-45/65/90/115 Eco.NOx Plus 3

1.2 Recommendations For a proper operating of the boiler, follow carefully the instructions. Any intervention on the appliance and heating equipment must be carried out by a qualified engineer. The manufacturer is not liable for any improper use of the appliance or failure to maintain or install the unit correctly (the user shall take care to ensure that the system is installed by a qualified engineer). Check the seal on the gas and water pipe connections. Check that the appliance is properly set for the type of gas used. Keep to the polarity shown on the terminals: phase (L), neutral (N) and earth. Check regularly that the installation contains water and is pressurised. Burn hazard in direct contact with the flame inspection window. 1.3 Ventilation 1.3.1 Chimney versions Do not obstruct the air inlets in the room (even partially). France: the cross section of the aeration vent, which is compulsory in the boiler room in which the boiler is installed, must comply with the DTU 61.1 (P 45 204) standard and, in particular, with the instruction on boiler room layout (Book 1764 April 1982). Belgium:the cross-section of the aeration vents, which are compulsory in the room in which the boiler is installed, must comply with the NBN D51-003 standard. 1.3.2 Forced flue versions Germany: the cross section of the ventiliation vents, which are compulsory in the room in which the boiler is installed, must comply with the VDI 2050 form 1 standard and with other prevailing regulations. Other countries: the cross section of the aeration inlet, which is compulsory in the premises in which the boiler is installed, must comply with the standards in force in the country. It is not necessary to provide ventilation of the premises in which the boiler is installed. Ventilation is required if a mechanical connection to the gas exists. 1.4 Maintenance - The servicing and cleaning of the boiler and the sweeping of the flue gas pipe and the bleed pot must be done at least once a year by a qualified professional. - Regularly check the level of water in the system and top up if required, taking care that cold water is not added suddenly into the boiler when it is hot. - We recommend taking out a maintenance contract. Do not drain the installation, except in cases of absolute necessity. Example: Several months' absence with the risk of ice in the building. 1.5 Adapting to another gas type Belgium: The operations required to switch from one gas to another must be carried out by a SERV'elite technician. Other countries: The operations required to switch from one gas to another must be carried out by your fitter. 4 DTG130-45/65/90/115 Eco.NOx Plus 20/01/2017-300005222-03

1.6 Liabilities 1.6.1 Manufacturer's liability Our products are manufactured in compliance with the requirements of the various applicable European Directives. They are therefore delivered with CE marking and all relevant documentation. In the interest of customers, we are continuously endeavouring to make improvements in product quality. All the specifications stated in this document are therefore subject to change without notice. Our liability as the manufacturer may not be invoked in the following cases: - Failure to abide by the instructions on installing the appliance - Failure to abide by the instructions on using the appliance - Faulty or insufficient maintenance of the appliance 1.6.2 Installer's liability The installer is responsible for the installation and commissioning of the appliance. The installer is required to observe the following instructions: - Read and follow the instructions given in the manuals provided with the appliance - Install the appliance in acordance with the legislation and standards currently in force - Perform the initial start up and carry out any checks necessary - Explain the installation to the user - If a maintenance is necessary, warn the user of the obligation to check the appliance and maintain it in good working order - Give all the instruction manuals to the user 1.6.3 User's liability To guarantee optimum operation of the appliance, the user must respect the following instructions: - Read and follow the instructions given in the manuals provided with the appliance - Call on qualified professionals to carry out installation and initial start up - Get your installer to explain your installation to you - Ensure the Appliance is serviced in accordance with the manufacturer's instructions by a suitable qualified person - Keep the instruction manuals in good condition close to the appliance 2 About this manual 2.1 Symbols used in the manual Caution danger Risk of injury and damage to equipment. Attention must be paid to the warnings on safety of persons and equipment. Specific information Information must be kept in mind to maintain comfort. Reference Refer to another manual or other pages in this instruction manual. 2.2 Abbreviations DHW: Domestic hot water. PPS: Polypropylene hardly inflammable. 3CE: Collective conduit for sealed boiler 20/01/2017-300005222-03 DTG130-45/65/90/115 Eco.NOx Plus 5

3 Description 3.1 Boilers The models presented are marketed in the various countries according to the countries' specific sales programme. Boiler self-standing 45 kw - 65 kw Boiler self-standing 90 kw - 115 kw Boiler with accumulator BC or BP 150,200,300 l - 45,65,90,115 kw 6 DTG130-45/65/90/115 Eco.NOx Plus 20/01/2017-300005222-03

3.2 Control panel 3.2.1 Electromechanical components 1 Main ON/OFF switch Pressure gauge * Depending on the model of the appliance, the pressure 2 gauge is manual (dial display) or automatic (pictogram display) On light / Alarm Green LED LIT: Normal operation 3 Red LED lit: Burner in safety condition Flashing red Led: abnormal operation (See chapter "7 Troubleshooting") 4 Safety control box reset button 3.2.2 Display 1 Text and numerical display 2 Graphic display bar for the programme in circuit A, B or C Light area: Reduced temperature heating period or tank load 3 disabled Dark area: Comfort temperature heating period or tank load 4 enabled 5 Flashing cursor showing the current time Number display (current time, adjusted values, parameters, 6 etc.) Active programme display, P1, P2, P3, P4 7 or Su: automatic Summer cut-off The arrows flash when setting values can be modified using 8 the + and - keys 9 Circuit operation symbols A, B, C Opening the 3-way valve Closing the 3-way valve Displayed circuit pump on Name of the circuit displayed 10 Symbol displayed above the active operating mode 11 Symbols indicating that the following inputs/outputs are active Burner on DHW load pump on Summer mode Not available 20/01/2017-300005222-03 DTG130-45/65/90/115 Eco.NOx Plus 7

3.2.3 Keys accessible when the flap is closed Setting the temperatures / Comfort temperature Reduced temperature Domestic hot water temperature Is used to adjust the selected temperature Operating mode selection keys AUTO Heating according to the time programme Forced Comfort mode: - until midnight if flashes - all the time if is steady Forced Low mode: - until midnight if flashes - all the time if is steady Antifreeze mode Tank load enabled mode: - until midnight if flashes - all the time if is steady 3.2.4 Keys accessible when the flap is open Manual "Summer" shutdown key The heating is switched off and DHW production is ensured. The symbols and Su are displayed. Standard programme key Reset of all time programmes Fitter settings access key Key for access to setting and measurements Page scrolling Line scrolling Return to the previous line Programming keys Enter (per 1/2 hour) the comfort temperature period or tank load enabled (dark area) Enter (per 1/2 hour) the reduced temperature period or tank load disabled (light area) A.B.C. PROG Return key Circuit display selection key Active heating programme selection key (P1, P2, P3 or P4) 8 DTG130-45/65/90/115 Eco.NOx Plus 20/01/2017-300005222-03

4 Energy savings This boiler handles all the functionalities that one may expect of a condensing boiler. Cutting edge technologies have been used not only in its exceptionally economic design in terms of finance and energy, and therefore also of environmental protection, but have also been applied to provide maximum comfort: heating for the whole house, hot water, incredibly simple to use and trouble-free operation thanks to its reduced noise level. 5 Commissioning Initial commissioning must be done by a qualified professional. 1. Check the water pressure in the installation. Top up with more water if necessary. 2. Open the gas valve. The gas condensing boiler is not content with using the heat contained in the exhaust gases (perceptible) but also takes advantage of latent heat (hidden). This energy is extracted from the steam produced during the combustion process and is not exploited by conventional boilers. The exhaust gases are here cooled in the boiler in such a way that the steam condenses and the additional heat from the exhaust gases is introduced into the heating system. The boiler meets the requirements of the German Decree on energy savings (Energie-EinsparVerordnung, EnEV) and offers truly exceptional value for money. 3. Control panel: - Open the panel flap. - Set the On/Off switch to. - Close the flap. 6 Switching off the boiler Set the On/Off switch to. Precautions to take if there is a danger of frost Heating circuit Use a correctly dosed antifreeze to prevent the heating water freezing. If this cannot be done, drain the system completely. In all cases, consult the fitter. Domestic hot water circuit Drain the domestic water tank and pipes. Precautions to take in the event of prolonged shutdown (one year or more) - The boiler and the chimney must be swept carefully. - Close the door of the boiler to prevent the internal circulation of air. - Remove the pipe connecting the boiler to the chimney and plug the nozzle. 20/01/2017-300005222-03 DTG130-45/65/90/115 Eco.NOx Plus 9

7 Troubleshooting Checks to make before calling your fitter: The burner will not start. Shutdown by the safety thermostat due to accidental overheating. To restart the boiler: Press the reset button. Call your fitter nonetheless. Shutdown of the safety system in connection with flue gas discharge. To restart the boiler: Press the reset button. If interruptions of this kind happen repeatedly, contact your fitter. It is possible that the combustion products evacuation pipe is totally or partially obstructed. The burner is operating but the radiators are cold. 8 Alarm messages - Bleed the radiators. - Top up the primary circuit with water. - Check that the heating pump is operating correctly. - If it is often necessary to top up the installation with water, contact your fitter. Before informing the fitter of a fault, make a note of the following information: - Type of product - Serial number - Type of combustible This information can be found on the rating plate stuck to the inside Message Probable causes Solution 24V SHORT-CIR Short circuit 24 V Reset the boiler. Contact your fitter. BURNER FAILURE I-CURRENT FAIL MCBA FAILURE XX MCBA FAILURE 5 MCBA FAILURE 11 DEF.MCBA 24 VALVE FAIL REARM CVI MCBA COM.FAUL Faults Probable causes Solution Igniter fault Ionization fault Gas valve defect No gas or presence of air in the pipe Ionization fault during operation Internal safety control box fault External influences Internal fault Boiler reversal sensor and return sensor Combined gas valve unit defective Control error Communication error between DIEMATIC and safety control box ROOM S.A FAIL. ROOM S.B FAIL. ROOM S.C FAIL. OUTL S.B FAIL. Fault of the corresponding sensor OUTL S.C FAIL. OUTSI. S.FAIL. SWIM.P.S.FAIL FAN OFF FAIL The fan is not working FAN ON FAIL The fan is working constantly BOILER S.FAIL. Boiler sensor defective DHW S. FAILURE Domestic hot water sensor defective SMOKE S.FAIL. Draught diverter thermostat defective BACK S.FAILURE Return sensor defective PARASIT FLAME Detection of a parasite flame STB BOILER Outlet temperature > 97 C STB SMOKE Flue gas temperature > 105 C STB BACK Return temperature too high Reset the boiler. Contact your fitter. 10 DTG130-45/65/90/115 Eco.NOx Plus 20/01/2017-300005222-03

Warranty You have just purchased one of our appliances and we thank you for the trust you have placed in our products. Please note that your appliance will provide good service for a longer period of time if it is regularly checked and maintained. Your fitter and our customer support network are at your disposal at all times. Warranty terms Starting from the purchase date shown on the original fitter's invoice, your appliance has a contractual guarantee against any manufacturing defect. The length of the guarantee is mentioned in the price catalogue. The manufacturer is not liable for any improper use of the appliance or failure to maintain or install the unit correctly (the user shall take care to ensure that the system is installed by a qualified fitter). In particular, the manufacturer shall not be held responsible for any damage, loss or injury caused by installations which do not comply with the following: - applicable local laws and regulations - specific requirements relating to the installation, such as national and/or local regulations - the manufacturer's instructions, in particular those relating to the regular maintenance of the unit - the rules of the profession The warranty is limited to the exchange or repair of such parts as have been recognised to be faulty by our technical department and does not cover labour, travel and carriage costs. The warranty shall not apply to the replacement or repair of parts damaged by normal wear and tear, negligence, repairs by unqualified parties, faulty or insufficient monitoring and maintenance, faulty power supply or the use of unsuitable fuel. Sub-assemblies such as motors, pumps, electric valves etc. are guaranteed only if they have never been dismantled. France The preceding dispositions are not exclusive of benefits for the purchaser of the legal guarantee as stated in Civil Code articles 1641 to 1648. Poland Warranty conditions are included in the warranty card. Switzerland The application of the warranty is subject to the terms and conditions of sale, delivery and warranty of the company marketing our products. Belgium The preceding dispositions about the contractual guarantee are not exclusive of profit if the need arises for the purchaser in Belgium of the applicable legal dispositions on hidden defects. Italy The duration of our warranty is shown on the certificate delivered with the appliance. Our liability as manufacturer may not be invoked in respect of incorrect use of the appliance, incorrect or insufficient maintenance thereof, or incorrect installation of the appliance (you must therefore ensure that installation and maintenance operations are carried out respectively by a qualified professional and by an after sales service company). The legislation laid down by European Directive 99/44/EEC, transposed by Legislative Decree No. 24 of 2 February 2002 published in O.J. No. 57 of 8 March 2002, continues to apply. Russia The foregoing provisions in no way affect the rights of the consumer, which are guaranteed by the legislation of the Russian Federation as regards hidden defects. The terms and conditions of warranty and the terms and conditions of application of the warranty are indicated on the warranty form. The warranty shall not apply as regards the replacement or repair of wearing parts under normal use. Such parts include thermocouples, injection nozzles, flame control and ignition systems, fuses and gaskets. Turkey Due to the laws and regulations the product life for this product is 10 years. During that time the producer and/or the distributor has to provide after sales services and spare parts. Other countries The above provisions do not restrict the benefit of the legal laws regarding hidden defects applicable in the buyer's country. 20/01/2017-300005222-03 DTG130-45/65/90/115 Eco.NOx Plus 11

en Appendix Information on the ecodesign and energy labelling directives

Contents Contents 1 Specific information..................................................................................3 1.1 Recommendations............................................................................. 3 1.2 Ecodesign Directive............................................................................ 3 1.3 Technical data - Boiler space heaters...............................................................3 1.4 Disposal and Recycling..........................................................................4 1.5 Product fiche - Temperature Controls...............................................................4 1.6 Product fiche - Boiler space heaters................................................................ 4 1.7 Package fiche - Boiler........................................................................... 5 2 300005222 - ErP02-24012017

1 Specific information 1 Specific information 1.1 Recommendations Note Only qualified persons are authorised to assemble, install and maintain the installation. 1.2 Ecodesign Directive 1.3 Technical data - Boiler space heaters This product conforms to the requirements of European Directive 2009/125/EC on the ecodesign of energy-related products. Tab.1 Technical parameters for boiler space heaters DTG 130 45 Eco.NOx Plus DTG 130 65 Eco.NOx Plus DTG 130 90 Eco.NOx Plus DTG 130 115 Eco.NOx Plus Condensing boiler Yes Yes Yes Yes Low-temperature boiler (1) No No No No B1 boiler No No No No Cogeneration space heater No No No No Combination heater No No No No Rated heat output Prated kw 41 62 84 107 Useful heat output at rated heat output P 4 kw 40.8 61.5 84.2 107.0 and high temperature regime (2) Useful heat output at 30% of rated heat P 1 kw 13.7 20.5 27.9 35.7 output and low temperature regime (1) Seasonal space heating energy efficiency ƞ s % 94 94 - - Useful efficiency at rated heat output and ƞ 4 % 89.3 89.4 88.2 87.5 high temperature regime (2) Useful efficiency at 30% of rated heat ƞ 1 % 99.6 99.5 97.4 97.3 output and low temperature regime (1) Auxiliary electricity consumption Full load elmax kw 0.055 0.088 0.136 0.213 Part load elmin kw 0.025 0.031 0.033 0.039 Stand-by P SB kw 0.011 0.011 0.011 0.011 Other characteristics Standby heat loss P stby kw 0.127 0.125 0.131 0.131 Ignition burner power consumption P ign kw - - - - Annual energy consumption Q HE GJ 126 190 - - Sound power level, indoors L WA db 49 49 - - Emissions of nitrogen oxides NO X mg/kwh 33 29 41 41 (1) Low temperature means for condensing boilers 30 C, for low temperature boilers 37 C and for other heaters 50 C return temperature (at heater inlet). (2) High temperature regime means 60 C return temperature at heater inlet and 80 C feed temperature at heater outlet. 300005222 - ErP02-24012017 3

1 Specific information See The back cover for contact details. 1.4 Disposal and Recycling Fig.1 Recycling MW-3000179-03 Warning Removal and disposal of the boiler must be carried out by a qualified installer in accordance with local and national regulations. If you need to remove the boiler, proceed as follows: 1. Switch off the boiler. 2. Cut the electrical power to the boiler. 3. Close the main gas valve. 4. Close the water mains. 5. Close the gas valve on the boiler. 6. Drain the installation. 7. Remove the air vent hose above the siphon. 8. Remove the siphon. 9. Remove the air/flue gas pipes. 10. Disconnect all pipes on the underside of the boiler. 11. Dismantle the boiler. 1.5 Product fiche - Temperature Controls Tab.2 Product fiche for the Temperature controls Diematic 3 Class II Contribution to space heating energy efficiency % 2 1.6 Product fiche - Boiler space heaters Tab.3 Product fiche for boiler space heaters DTG 130 45 Eco.NOx Plus DTG 130 65 Eco.NOx Plus Seasonal space heating energy efficiency class A A Rated heat output (Prated or Psup) kw 41 62 Seasonal space heating energy efficiency % 94 94 Annual energy consumption GJ 126 190 Sound power level L WA indoors db 49 49 See For specific precautions on assembly, installation and maintenance: see the chapter on Safety Instructions. 4 300005222 - ErP02-24012017

1 Specific information 1.7 Package fiche - Boiler Fig.2 Package fiche for boilers indicating the space heating energy efficiency of the package Seasonal space heating energy efficiency of boiler 1 I % Temperature control from fi che of temperature control Class I = 1%, Class II = 2%, Class III = 1.5%, Class IV = 2%, Class V = 3%, Class VI = 4%, Class VII = 3.5%, Class VIII = 5% + 2 % Supplementary boiler from fi che of boiler Seasonal space heating energy effi ciency (in %) 3 ( - I ) x 0.1 = ± % Solar contribution from fi che of solar device Collector size (in m²) Tank volume (in m³) Collector effi ciency (in %) Tank rating A* = 0.95, A = 0.91, B = 0.86, C = 0.83, D - G = 0.81 (1) 4 ( III x + IV x ) x 0.9 x ( /100) x = + (1) If tank rating is above A, use 0.95 % Supplementary heat pump from fi che of heat pump Seasonal space heating energy effi ciency (in %) 5 ( - I ) x II = + % Solar contribution AND Supplementary heat pump select smaller value 4 5 6 0.5 x OR 0.5 x = - % Seasonal space heating energy efficiency of package 7 % Seasonal space heating energy efficiency class of package G F E D C B A A + A ++ A +++ <30% Boiler and supplementary heat pump installed with low temperature heat emitters at 35 C? from fi che of heat pump 7 + (50 x II ) = % The energy effi ciency of the package of products provided for in this fi che may not correspond to its actual energy effi ciency once installed in a building, as this effi ciency is infl uenced by further factors such as heat loss in the distribution system and the dimensioning of the products in relation to building size and characteristics. AD-3000743-01 I The value of the seasonal space heating energy efficiency of the preferential space heater, expressed in %. 300005222 - ErP02-24012017 5

1 Specific information II III IV The factor for weighting the heat output of preferential and supplementary heaters of a package as set out in the following table. The value of the mathematical expression: 294/(11 Prated), whereby Prated is related to the preferential space heater. The value of the mathematical expression 115/(11 Prated), whereby Prated is related to the preferential space heater. Tab.4 Weighting of boilers Psup / (Prated + Psup) (1)(2) II, package without hot water storage tank II, package with hot water storage tank 0 0 0 0.1 0.3 0.37 0.2 0.55 0.70 0.3 0.75 0.85 0.4 0.85 0.94 0.5 0.95 0.98 0.6 0.98 1.00 0.7 1.00 1.00 (1) The intermediate values are calculated by linear interpolation between the two adjacent values. (2) Prated is related to the preferential space heater or combination heater. Tab.5 Package efficiency DTG 130 45 Eco.NOx Plus DTG 130 65 Eco.NOx Plus Seasonal space heating energy efficiency of package % 96 96 6 300005222 - ErP02-24012017

300005222 - ErP02-24012017

DE DIETRICH THERMIQUE S.A.S +49 (0)25 72 / 9161-0 +49 (0)25 72 / 9161-102 info@remeha.de +7 (495) 221-31-51 info@dedietrich.ru ES DE DIETRICH THERMIQUE Iberia S.L.U. www.dedietrich-calefaccion.es C/Salvador Espriu, 11 08908 L HOSPITALET de LLOBREGAT +34 935 475 850 info@dedietrich-calefaccion.es DE DIETRICH SERVICE www.dedietrich-heiztechnik.com Freecall 0800 / 201608 IT CZ DUEDI S.r.l. www.duediclima.it Distributore Ufficiale Esclusivo De Dietrich-Thermique Italia Via Passatore, 12-12010 San Defendente di Cervasca CUNEO +39 0171 857170 +39 0171 687875 info@duediclima.it BDR Thermea (Czech republic) s.r.o www.dedietrich.cz Jeseniova 2770/56 130 00 Praha 3 +420 271 001 627 dedietrich@bdrthermea.cz AD001NU-AJ Copyright All technical and technological information contained in these technical instructions, as well as any drawings and technical descriptions supplied, remain our property and shall not be multiplied without our prior consent in writing. Subject to alterations. 20/01/2017 300005222-001- 03 DE DIETRICH THERMIQUE 57, rue de la Gare F- 67580 MERTZWILLER - BP 30