Dear Customer! FIRE FIGHTERS CALL STATION - INTRODUCTION

Similar documents
Call stations and extensions

Voice Alarm. Multifunctional Voice Alarm Systems. certified to EN54

New Products sounds more than safe..

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

clino System 99 protect Safety in Enforcement and Forensic Facilities Communication solutions for high-security areas

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Vocia VACIE. Reference Guide

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

VACIE REFERENCE GUIDE REVISION 1.2.6

PROJ. NO SECTION PAGING, SPEAKERS AND HARD-WIRED CLOCK SYSTEMS

SAFETY AT SCHOOLS. We supply sound, not equipment. the integration of intercom and voice alarm systems makes schools safe.

Flexibility right from the start. PAVIRO Public Address and Voice Evacuation System with Professional Sound Quality. boschsecurity.

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

On the job around the clock 24/7: Fire detection systems

PA/VA solutions for transport industry

PUBLIC ADDRESS, BACKGROUND MUSIC AND VOICE ALARM SYSTEM

Concepts for the secure networking of large building complexes

Experts in PA/VA Systems

WW Ability to connect standalone minives units. Integrated mini PA/VA unit. We make everyday life safer. (incl. fireman and zone microphones)

Cerberus PACE Operating terminals / Call stations Operation Manual

Boosters. DN C Series Flow rate 2.9 to 19.6 m³/min Rated motor power 22 to 45 kw Initial pressure 3 to 13 bar Final pressure 10 to 45 bar

US Retail Price List. June, Sales Contact

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

D 8A / D 10A / D 12A / D 15A D 12A SUB / D 15A SUB

Process Gas Chromatograph

The Ultimate, Digital Public Address & Voice Alarm System FLEXIBILITY UNLIMITED

CATALOGUE Controls/Networks STRACK LIFT AUTOMATION. MULTiBUS -Coupler

PowerLogic Branch Circuit Power Meter (BCPM)

Entero Voice Alarm system.

Denon USA A/V Receivers

RFP Addendum 2 March 31, 2016

SECTION 4. Parts Management

User Guide English. Manual Version 1.0

AUDIO- AND ALARMMANAGEMENT

FI6000 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Fire Alarm Interface

VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Rotary Screw Compressors SX Series With the world-renowned SIGMA PROFILE Free air delivery from 0.26 to 0.81 m³/min, Pressure 5.

X-618 Digital Public Address and Voice Alarm System. Cherian George Product Manager PAVA systems

Total Unified Solution for Building Integration: Communications, Access Control, Video Surveillance and Fire

EduCam360-B. Fisheye Panorama Network Camera Manual

INTRON-D plus. Alarm and Warning Function. Automatic and/or manual triggering of alarms and warnings to protect human lives and to evacuate people.

C Command. Engine monitoring that puts you in control

SI120 Guarto Easy I. Alarm system. Fire & Security Products

SOUNDCONCEPTS. for restaurants & retail. We supply sound, not equipment but a relaxed and pleasant shopping experience all the same.

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Temperature Solutions Line Card

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

AIS750 Series Alarm Annunciator

VIDEO INTERCOM Products and Solutions 2017 Ver. 1

Networked Public Address and Voice Evacuation

VOICE ALARMING SYSTEM»ONE-BOX-DESIGN« EN / EN 54-4 / VDE / EN / VDE 0828 THE SIMPLE»ALL-IN-ONE«SOLUTION.


Esmi Sense FDP Fire detection panel with ALC2 loop controller

AE300. Integrated Voice Alarm System

AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

ANNEX A.1 TECHNICAL SPECIFICATIONS Negotiated Procedure FRA Provision of Security Supplies and Installations

Rotary Screw Compressors. SK Series With the world-renowned SIGMA PROFILE Flow rate 0.53 to 2.70 m³/min, Pressure 5.5 to 15 bar

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

MODEL AC-SCC-5 INSTALLATION, OPERATION & MAINTENANCE MANUAL

Innovative protection that combines power and flexibility

Discover our product portfolio! All around heating and solar thermal control technology.

ALARM SECURITY PRODUCTS

Voice Alarm system integration

We are heard everywhere. DSE electronic sirens

Fire control panels FC726 FC726-XA

Multi-Gas-Controller MGC2

Organize your security with PSIM + software

Organize your security with PSIM + software

EN ASTRO-PA/GA System. ASTRO-PAGA Digital IP Public Address & General Alarm SYSTEM for INDUSTRIAL SAFETY APPLICATIONS

Solutions for Mass Notification Systems

Eco-Flex Drying Kiln. The Economical and Flexible Solution for Perfect Wood Quality.

OPEN THE DOOR TO INNOVATION. 2N ELEVATOR SYSTEMS - Emergency communication devices for any lift.

AutroVoice voice alarm system AUTROVOICE VOICE ALARM. Loud and clear information

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

ClampOn DSP Corrosion- Erosion Monitor

SUPREMATouch Modular Fire & Gas Detection System

1 Application Note Bosch Security Sys Sy tems m Bosch Security Systems Smart Safety Link -

Medicontrol itcp Intelligent Theatre Control Panels

SUBTILE-BL / SUBTILE-W

Flair 500 Series Annunciators

GAI-Tronics Corporation. Serverless Page Party (SP2) Publication : SP2 Intelligent Intra-Plant Communication and Emergency Notification System

INSTRUCTION MANUAL. Full Size Gas Convection Oven

Integrated Security Solutions

Networked Public Address and Voice Evacuation

WEBs AX Security. Integrated Security With Simple, Web-Based Management

by Honeywell VOICE ALARM SOLUTIONS BROCHURE

SmartLine Pressure Transmitters Modular, Accurate and Robust for the Lowest Cost of Ownership

E3 Series Broadband System

Protect your people, assets and environment while ensuring operational performance.

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

FlexiSmoke WSC 520 / WSC 540 / WSC 560 Modular smoke ventilation panel 20-60A

Emergency call system for lifts: SafeLine SLMX2 Quick-guide

ADAC. Advanced Deaerator Control

FUNCTIONAL SAFETY MANUAL

SETTING UP A VIRTUAL KEYPAD WITH A DSC POWERSERIES ALARM SYSTEM

E3 Series Broadband System

Basic Fire Alarm SystemTraining. Arman Alnasar

Transcription:

FIRE FIGHTERS CALL STATION - INTRODUCTION Dear Customer! The main focus of our research work is and always has been the development of practical devices that are fl exible, versatile, reliable, future-proof but still easy to handle. In close cooperation with electrical consultants, system architects and operators of public address systems ITECNET has emerged and grown. In addition, all our know-how from many years of experience in the fi eld of audio and digital technology have been integrated into this product ITECNET allows the build-up of the largest and most complex audio systems, with relatively simple and clear operation and confi guration. Due to its modular design, digital IO s, analog inputs and a serial interface, it offers beyond its function as a base station, a large number of monitoring and control functions. The integrated SD card reader / player allows the storage and playback of alarm texts and announcements. This manual describes the hardware of the ITECNET Fire Fighters Call Station. For knowing the entire system, all its possibilities and for executing the necessary confi guration tasks the software manual is required in addition. Please observe during the installation / operation of the ITEC Fire Fighters Call Station all listed safety instructions in this manual; furthermore data and examples provided ensuring the optimum usage of the device. Lots of joy and success - The ITEC Acoustics Team 2 www.itec-audio.com ITEC FIRE FIGHTERS CALL STATION

FIRE FIGHTERS CALL STATION Safety instructions When installing the device, the local connecting conditions, the required protective measures and all relevant standards (ÖNORM F 3033, TRVB S 158, etc.) have to be observed. The installation and confi guration of the ITEC Fire Fighters Call Station must be performed by trained personnel only. For the confi guration the original software ITEC NETDESIGN has to be used exclusively. The voltage supply and communication connection is ensured via the fi re alarm cable with functional integrity to the ITECNET ENS centre or any other available sub-centre. The device has been designed for wall installation. For cabinet installations please ensure adequate air circulation. Mounting of the device in closed timber furniture is not allowed.. Only a connection to networks, which are compliant to IEEE 802.3 (Ethernet), is allowed. Never try to open the device by force or by unscrewing. The product does not contain parts that can be repaired by amateurs. Please contact the manufacturer or a local distributor. Do not apply temperatures above 50 C, humidity larger than 95% or rain to the device. Caution: Before carrying out any modifi cations on the device (only by qualifi ed personnel) the power supply has to be disconnected. Use a dry or slightly damp cloth to clean the housing surface and the keyboard. Aggressive or abrasive cleaners should be avoided. In particular in monitored systems for voice alarms you have always to ensure that microphone and integrated speakers of the device are not concealed. The use of other microphones without consulting the manufacturer or distributor is not allowed! ITEC FIRE FIGHTERS CALL STATION www.itec-audio.com 3

FIRE FIGHTERS CALL STATION Block diagram A B Ethernet 4 Logic Inputs 4 Logic Outputs 6 External Controls RS 232 Ethernet-Unit DSP Sig+ Sig- +12 V IN 1 1 2 3 +12 V IN 2 0 db +30 db + - 0 db +30 db + - VCA - +20 dbs VCA - +20 dbs A/D-Converter Feed CH 1-256 Get CH 1-256 Input-Matrix OUTPUT UNIT 1 MIX Volume Priority OUTPUT UNIT 2 EQ Delay EQ Delay D/A-Converter + - + - OUT 1 OUT 2 Sig+ Sig- User Interface Fire Fighters Call Station 6 www.itec-audio.com ITEC FIRE FIGHTERS CALL STATION

FIRE FIGHTERS CALL STATION Connection Terminal Fire Fighters Call Station 24V 0V Schirm TX + TX - RX + RX - SD-Card By default, every Fire Brigade Call Station has an SD slot. You can insert micro SD cards with up to 2GB storage capacity. Up to 256 sound fi les can be stored on the SD card. These fi les can be alarm texts, safety instructions, audio signals as well as advertising texts or jingles. Spare Parts ITECNET Fire fi ghters call station housing in compliance with ÖNORM F3033 ITECNET SpiderMike2 main print ITECNET SpiderMike2 Fire fi ghters call station user interface ITECNET DH-95NI Fire fi ghters call station microphone ITECNET NKK Fire fi ghters call station button, red ITECNET NKK Fire fi ghters call station button, green ITECNET NKK Fire fi ghters call station button actuation protection ITECNET Fire fi ghters call station LED, green, with installation base ITECNET Fire fi ghters call station LED, orange, with installation base ITECNET Fire fi ghters call station LED, red, with installation base ITEC FIRE FIGHTERS CALL STATION www.itec-audio.com 7