HUMIDITY MANAGEMENT MODULE TYPE H122 Digital USER INSTRUCTIONS

Similar documents
Advance Humidity Pump with Octagon 20 and 40 Advance EX Upgrade

Advance Humidity Pump

Octagon 20 Parrot Rearing Module

OCTAGON 10 INCUBATOR

Read the instructions before use!

OVA-EASY ADVANCE. HATCHER User Instructions

Octagon 100 and 250 Digital high performance egg incubators. Users instructions

Read the instructions before use!

OVA-EASY ADVANCE. HATCHER User Instructions

Octagon TLC-4 and TLC-5 Thermal Life-support Cabinet

HUMIDITY IN INCUBATION

Read the instructions before use!

Read the instructions before use!

Octagon 20 Advance and Octagon 40 Advance high performance egg incubators. User instructions

Read the instructions before use!

OVATION 56 EGG INCUBATORS CLEANING / SERVICE GUIDE

Read the instructions before use!

Read the instructions before use!

Read the instructions before use!

Read the instructions before use!

Read the instructions before use!

User Instructions Models Covered - (OE190, OE380, OE580)

OVA-EASY 100 ADVANCE User Instructions

Octagon 20 Eco and Octagon 40 Eco egg incubators. User instructions

TLC-40 Eco / TLC-50 Eco. User instructions

TLC-40 Advance / TLC-50 Advance. User instructions

Record your appliance serial number here:

Read the instructions before use!

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

CONTAQ X3 CONTAQ X8. Contact Incubation Technology. User Instructions. Section Subject Page

MULTI FLOW HYDROPONIC SYSTEM

Operating instructions for Grumbach Incubators

Q3000 US Issue 01. Operating Instructions

MINIMED 670G SYSTEM CHANGING THE MINIMED SILHOUETTE INFUSION SET QUICK REFERENCE GUIDE

GENERAL FITTING GUIDE THERMOSTATIC BAR SHOWER MIXER with RIGID RISER KIT

SCHWAN INSTALLATION GUIDE

SCHWAN INSTALLATION GUIDE

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option

OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN

TK-1801, TK-1811 TK-1801, TKR-1811

Window Kit Installation Instructions

Part Nos.: Laminators

Product instruction manual Easymount Wide Format Laminators

i-cube Microplate Incubator E10030

OPERATING & SERVICE PARTS MANUAL HDS-215 COMBINATION SHRINK SYSTEM

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

TK-1001, 1101, 1201, 1301, 1601

Models TX-KE and TX-KP Toxic Gas Transmitters

INSTALLATION INSTRUCTIONS. WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES. COMPOSITE FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES

Operating Instructions Proudly made in Australia.

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Fitting Instructions: Street Triple Rx, Daytona 675 from VIN and Daytona 675 R from VIN A

CEILING FAN OWNER S MANUAL

Enzo Concealed Shower Mixing Valve

Easy-Lam School Budget Roll Laminator

OPERATING INSTRUCTIONS FOR LEEC AUTOMATIC CO2 INCUBATORS. MODELS GA2000 and GA2010 MODELS GA3000 and GA3010 With Infrared CO2 detectors CONTENTS

Closomat Lima Vita installation & user guide

Telo Shower Mixing Valve TL10016CP

Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP

S-1200 Series Currency Counter Operating Manual. Models S-1200, S-1215 and S-1225

Auto Top-Off & Ultra-Precise Liquid Level Controller II

Automatic Humidity Controller. Model 512 (Revision C) Operating Manual

Goldpress 4+ OPERATING, MAINTENANCE AND SAFE USAGE MANUAL OF THE GOLDPRESS 4+ MACHINE

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Plus Bath Shower Mixing Valve CP and PL30020CP

TA-12/HT12 Tabber. OPERATING GUIDE Revised:

Gfp 400 Series August Gfp 463 TH. Please read this manual carefully before operating!

OPERATING MANUAL Gfp 255C Please read this manual carefully before operating!

DICKSON KT6 DICKSON. Temperature Chart Recorder. Specifications. Product. Display Symbols. Information & Operating. Contents:

Spy model 673 wet sponge holiday detector ope rati ng instructions

MINIMED 670G SYSTEM CHANGING THE MINIMED MIO INFUSION SET QUICK REFERENCE GUIDE

TA-12. Tabbing System USER'S GUIDE

Reacti-Therm I and III Heating Modules

General System Layout Sketch

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Instruction Manual BELLSOUTH TM 100 EGG INCUBATOR. Bellsouth TM 100 egg incubator Models. Bellsouth TM 100 egg incubator (Manually hand turn eggs)

ASPIRE Laboratory Aspirator

Technical data. Bathroom/shower room installations. Water services (WRAS approved)

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

POWER JET SERIES. IWATA STUDIO SERIES POWER JET SERIES AIR COMPRESSORS IS-900, IS-925 and IS-975

GLYCOL CHILLER INSTRUCTIONS IMPORTANT: BEFORE OPERATING PLEASE SEE INSTRUCTIONS ON PAGE 5

READ AND SAVE THESE INSTRUCTIONS OWNER S MANUAL FOR BYPASS AND FAN POWERED HUMIDIFIERS. Small or Large Bypass 12 Water Saver Bypass 13 Fan Powered 14

Product instruction manual Easymount Wide Format Laminators

HE360 Humidifier Installation Kit

Tornado Operations & Maintenance Manual

QUANTURA DISHWASH DOSING SYSTEMS. revolutionary dispensing solutions

* Styles may vary but assembly will be consistent with this manual. Fountain Heads. Warnings

ONE PIECE TOILET LT3. Model: MPN: B0940 INSTALLATION INSTRUCTIONS. Version: 1.0

Kiko Bath Shower Mixing Valve KK90015CP

FD 90 / FD 95 Rotary Perforators

ASTRO ENVELOPE FEEDER AMC FOR HEIDELBERG PRINTMASTER INSTALLATION AND OPERATING INSTRUCTIONS

User manual NORDIC. Juice machine U / EN. Rev Your retail dealer

Reliability in Laboratory Centrifuges Since Operator s Manual. Models 614B, 614L, 614U/UL and 614V/VL Laboratory Centrifuge. Rev. 5.

E25 CONVECTION OVEN E25MS CONVECTION OVEN SERVICE MANUAL

Marco Beverage Systems Ltd. INSTRUCTIONS FOR MODEL Revision 9 th Mar Uber Boiler

Built-in Gas Hob CZ55554 CZ55571

Transcription:

HUMIDITY MANAGEMENT MODULE TYPE H122 Digital USER INSTRUCTIONS Contents Section Subject Page 1 Introduction 2 2 Unpacking 2 3 Principle of Operation 3 4 Installation 3 5 Operation 5 6 Routine Maintenance 5 7 Troubleshooting 6 8 Specifications 7 1.0 INTRODUCTION 1

These instructions detail the installation and operation of you new H122 Digital Automatic Humidity Management Module. Please read them carefully before setting up your machine to achieve best results and keep these instructions safe for future reference. The H122 module is optional accessory for the Brinsea Octagon 100 or 250 egg incubators and cannot be used in any other application. The H122 offers convenient and refined measurement and control of humidity within the incubator. If the Octagon 100 or 250 incubator has been ordered from new with the H122 fitted then only the operational instructions apply. If the H122 is to be retro-fitted to an Octagon 100 or 250 please first follow the installation instructions (in the shaded sections.) These instructions are limited to the operation and function of the H122 humidity Control Module only, please refer to your incubator instructions for more general guidelines on humidity in incubation. FEATURES Continuous digital metering of relative humidity (%RH) Proportional control easily set against scale Precision bulk polymer sensor Pumped water flow - not level dependent Water Tube Humidity Pump Pump Run Indicator Power Indicator Power Switch Digital Readout Signal Lead Adjustment Knob 2.0 UNPACKING The H122 Digital comprises: 2

1 Type H122 Humidity module control unit Containing all control and indication functions and the water pump. 1 Sensor unit Contains the (removable) sensor and sensor flex socket. Fits through the fan mounting plate at the rear of the incubator. 1 Sensor unit clip Screws to the fan mounting plate of the rear of the incubator to receive the sensor unit. 1 Length water tube 3m (10 feet) Silicone rubber tube for interconnecting and for peristaltic pump replacement. 1 Sensor flex 1m (3.3 feet) Flex with jack plugs for connecting between control unit and sensor unit. 2 Sheets of evaporating pad - To be cut to suit the incubator. 4 Fixing screws For securing the H122 module to the incubator. 2.1 Remove all tape and packing from the module and parts. Retain the box and packing materials to enable the unit to be repacked. Please take care not to discard the pack of heavy white evaporating pad paper. 2.2 Identify each part and check that they are all present and undamaged. If there are any parts damaged or missing please contact your retailer or Brinsea Products (at the address at the end of the document) Note also that the black humidity sensor fits into a socket in the sensor unit and can be pulled to remove. Take care not to lose or damage the sensor, replacements are expensive. 2.3 Check also that the electrical supply matches the machine s requirements (marked on the technical label on the back of the control unit). 2.4 Complete and return your guarantee card to register for the free two year guarantee covering your humidity module. 2.5 Go to www.brinsea.co.uk and register as a free member of the Brinsea e-mail group to receive the latest news and information such as advance notice about new products, special offers, exclusive competitions and much more. 3.0 PRINCIPLE OF OPERATION The sophisticated bulk polymer sensor provides a highly accurate, linear signal of the relative humidity level within the incubator back to the Humidity Module which then displays this level on the digital meter. The control system operates a tiny in-built water pump which transfers exactly the amount of water required into the incubator to maintain the required relative humidity which is set by the user. The control system compensates for changes in relative humidity level and, within working limits, will maintain a constant relative humidity level. 4.0 INSTALLATION Fitting the Module (when purchased separately from the incubator) Fitting of this part must be carried out by a suitably qualified person 3

BEFORE STARTING DISCONNECT THE UNIT FROM THE MAINS SUPPLY 4.1 The Humidity Module is mounted on the plastic rail on top of the incubator immediately behind the temperature control housing. Locate the unit in position and drill four 2mm (5/64 ) fixing holes in the mounting rail corresponding to the holes in the H122 housing. 4.2 Remove the cover of the temperature control and remove the power supply cover. Identify which power supply circuit is fitted from the diagrams below. Connect the two yellow captive leads from the H122 to the two right hand connections as below as shown (either way around). Ensure all existing connections are left as they were: Later power supply circuit layout: 4.3 Refit the power supply cover and temperature control cover. 4.4 Remove the two plugs fitted into the black panel on the rear of the incubator. Replace one with the sensor clip by drilling two 3 mm (1/8 ) holes and fastening the clip with the screws provided. Note: On some early incubators these plugs may be missing - if so please contact the Service dept. at the address at the end of these instructions. 4

4.5 Drill a 4mm (3/16 ) hole through the second plug and replace it in the hole. Pass a length of tubing from the suction side of the pump on the H122, through the guide clip and through the hole in the plug and into the water reservoir in the incubator. Alternatively use an external reservoir such as a 500ml water bottle standing behind the incubator. Mounting the sensor unit 4.6 Push a 75mm (3 inch) length of the silicone tube to the nipple on the sensor unit adjacent to the black sensor (moistening the end of the tube helps). Ensure the small black rectangular sensor is firmly pushed into its socket in the sensor unit. If it should come out, ensure it is replaced the right way up with the three pins closer to the top. If inserted upside down, the sensor will give an incorrect negative reading. Feed the unconnected outlet tube through the sensor mounting clip on the back of the incubator and ease the sensor unit into the mounting clip, until it locates with a click. 4.7 From inside the incubator feed the outlet tube through the tube guide clip at the back of the machine and into the evaporating tray. 4.8 The H122 Humidity Management Module is supplied with a length of silicone tube fitted around the pump rotor. This length will wear and need periodic replacement. It can also become flattened if left unused for some time because the inside walls of the tube will stick to each other around the rotor and prevent water passing through. This can happen from new if the unit has been stored for a time. Either replace this length of tube (see section 6) or remove it and roll it between finger and thumb to unstick it. 4.9 Cut a piece of evaporating pad to 10cm x 28cm and place on the tray to the rear of the incubator and lay the outlet pipe on top of the pad. Note: The second V shaped piece of evaporating pad described in the incubator instructions must not be used in conjunction with the Humidity Module. 4.10 Ensure that there are no kinks in the tubing especially where they pass through the tube guide clips. 4.11 Connect the sensor flex from the Module housing to the sensor unit. 5.0 OPERATION The module will be factory calibrated but may be returned to the address at the end of these instructions for recalibration for a small fee. 5.1 Ensure that the suction (inlet) tube is below the water level either in the internal reservoir or in an external water bottle. 5.2 Press the power supply switch. Power indicator will light. Turn the humidity control knob anti-clockwise to minimum. 5.3 The meter will give a readout of humidity, at incubation temperature this will usually be a fairly low figure (15 to 30%). Allow 5 minutes for the reading to stabilise and adjust the humidity control knob to raise the humidity, the pump will run and the pump run indicator will light. To achieve the desired relative humidity 5

level allow 30minutes between adjustments and use the meter reading as your guide to turning the control knob up or down. 5.4 When the humidity level is stable the pump will cut in and out evenly, pumping small amounts of water to offset moisture losses as incubator air is passed out through ventilation holes. 5.5 Refer to your incubator instructions for suggested humidity levels. 6.0 ROUTINE MAINTENANCE 6.1 Changing the pump tube The peristaltic pump will need to have its tube replaced about every 3 months. Cut a length of tube to about 135mm (5¼ ). Remove the connectors and pull off the old tube. Replace with the new tube, avoiding twists. Use the diagram on the product label to thread the tube exactly as shown over the pump head. The tension must be sufficient to ensure complete occlusion of the tube without unnecessary flattening between the pump rollers. Adjust tube length as necessary. Ensure that the tube does not stick together if left for long periods by unhooking it during storage. 6.2 Changing the evaporating pad Change the pad as necessary to maintain good evaporating efficiency. If chicks are to be hatched in the incubator, change the pad after each hatch to avoid bacterial contamination. 7.0 TROUBLESHOOTING The control module is calibrated from 0 to 100% RH and is theoretically capable of controlling throughout most of the range. However, the minimum and maximum levels of humidity achievable in an incubator depend upon several factors, particularly the fresh air ventilation rate. You may need to allow 24 hours for humidity to stabilise after making changes. If you cannot get the level of RH you want, consider these notes: 7.1 Humidity will not go low enough First increase the fresh air ventilation level - enlarge ventilation holes in the incubator cabinet. This will help to disperse the moisture given up by the eggs. There will still remain a lower limit determined by the moisture content of the ambient air, particularly in warm humid conditions. This can only be countered by dehumidification of the room air outside the incubator with a branded dehumidifier but is rarely a problem in practice except for ratites. 7.2 Humidity will not go high enough Restrict fresh air ventilation to the minimum safe level. Remember embryos need to breathe! Increase evaporating pad area. If the pad is too small, you may have a flood in your incubator. Do not attempt to achieve higher than 80% RH. Check that water is reaching the incubator when the pump runs if not check the whole length of the tubing for kinks and check that the tubing around the pump has not become permanently flattened. If it has, replace 6

the pump tube. Silicone tubing is very flexible but can be damaged by sharp finger nails. A tiny perforation on the suction side of the pump will let in air and prevent the pump drawing water. 7.3 If further problems are experienced please contact your retailer or Brinsea Products at the address below. 8.0 SPECIFICATIONS Sensor: Water Transfer: Sensor accuracy +/- 3%. Hysteresis 0% R.H. Response time 2 minutes In-built peristaltic pump Maximum water flow rate 30g/hour Control setting and metering: Indicated in % RH (linear) Electrical supply: 15v AC from temperature control module on incubator Dimensions: 170mm x 200mm x 90mm (W x D x H) (module) Brinsea Products Ltd, Station Road, Sandford, N. Somerset, BS25 5RA Tel: (01934) 823039 Fax: (01934) 820250 e-mail: sales@brinsea.co.uk, website: www.brinsea.co.uk 7