COMPOSITE CHIMNEYS. Géza Kecskeméthy, István Kovácsay, [Balázs Zsigmond]: Kompozitor Co. Ltd., Hungary

Similar documents
Solid Fuel Range Cookers and Stoves Catalogue KVS MORAVIA

Irish Standard I.S. EN :2009

Forced Draft Boiler Flue Gas Venting: Problems & Solutions. Presented by Steve Connor and Patrice Gouin January 27, 2016

Solid Fuel Range Cookers and Stoves Catalogue KVS MORAVIA

This document is a preview generated by EVS

Technical Guidance CE Marking of Metal Chimneys and Flues

DualGuard Fluoropolymer Barrier FRP Duct. Composites USA. Fluoropolymer Barrier FRP Duct. A Critical Process Systems Group Company LISTED

GRINNELL Rapid Installation Pivot-Bolt

European Sprinkler Campaigns. Edinburgh, 20 January 2010 Alan Brinson

Furenflex RWV Advanced Liner

Heating with wood chips & pellets

Sýnishorn General requirements for components used in drains and sewers

Geomembranes that work

Log fired heating system

Metal Woodprint The natural look

English. Heating with logs & wood pellets 20-40

qüé=`üáãåéó An effective chimney is an important part of any successful wood-burning system.

Do not use this vent pipe or fittings for venting incinerators of any kind.

This document is a preview generated by EVS

This document is a preview generated by EVS

Boiler Draft Equipment

Side by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions

For more information on Tarkett go to

GB162 Concentric Horizontal Vent Kit

TWIN - GAS. Concentric flue gas system for decorative gas fires.

This document is a preview generated by EVS

Back to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions

Free-standing chimneys Part 6: Steel liners Design and execution

Geomembranes that work

COMPANY PROFILE.

Textile fire protection closures EI 30/90

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

This document is a preview generated by EVS

SECTION DUCTWORK

Sýnishorn Fire resistance test for service installations - Part 1: Ventilation ducts

This document is a preview generated by EVS

Stainless Steel Cable Ties

Airborne Imagery Potential Role in Monitoring Climate Change

Z-DENS Z-FLEX. Polypropylene Vent Systems for High Efficiency Condensing Appliances. Single Wall Rigid Flexible Liner Concentric

FINAL DRAFT FprEN

The advantages of closed heating systems. White paper

Heating with pellets kw

Air and dirt in closed systems

This document is a preview generated by EVS

Keeping European Consumers safe Rapid Alert System for dangerous non-food products 2014

COMBI COMPACT HRE COMBI COMPACT HRE HRE

This document is a preview generated by EVS

Introduction. A soil is an earth concrete. Composition of a soil

This document is a preview generated by EVS

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

Metal Woodprint The natural look

CHIMNEY SYSTEMS PRODUCT OVERVIEW. LAUNDRY CHUTES.

SPECIAL SPECIFICATION 3687 Impermeable Liner

This document is a preview generated by EVS

Expansion vessel in a solar installation. White paper

PASSIVE AND ACTIVE FIRE PROTECTION OF THE AIR HEATED SOLAR HOUSES

This document is a preview generated by EVS

Forum for European Electrical Domestic Safety FEEDS. B. DOME FISUEL

EXECUTION OF SPECIAL GEOTECHNICAL WORKS - MICROPILES IRISH STANDARD I.S. EN 14199:2005. Price Code. Údarás um Chaighdeáin Náisiúnta na héireann 93.

SIZING HANDBOOK & APPLICATION GUIDE

Part J of the Building Regulations: Changes for 2010 Tuesday 28 th September 2010 Presenter: David Bleicher

Building Constructions 4


Owner s Manual for. PennStoker

Enviro International Corporation. WET SCRUBBER

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

This document is a preview generated by EVS

CHIMNEYS AND VENTS CHAPTER 8

Market Dynamics. Cut Flowers Europe June The Netherlands. Netherlands Auctions. 4 July 2016

HunterDouglas Silhouette Shades are unique and extremely versatile window shades; soft as silk, elegant as a curtain and practical as a venetian

Large-scale fire test for interior materials of the Korean high speed train

Bathroom July Topics

This document is a preview generated by EVS

Industrial Fiberglass Specialties, Inc. 521 Kiser Street Dayton, OH Tel: Fax:

This document is a preview generated by EVS

Leading European manufacturer of fireplace stoves and fireplace inserts

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

Accuracy counts! Sensors with analog output

A WMIA Partner of the Year Winner S-Series Enclosureless Dust Collector

Skorstenar Utförandestandard för metallskorstenar


2012 INTERNATIONAL FUEL GAS CODE VENTS

SOUTH AFRICAN NATIONAL STANDARD

SAUNA BARREL 3.0 m, Ø Plans: with and without terrace

PTG, SWT Series. Heat Recovery Systems

International Customer Edition Date: June 2014

This document is a preview generated by EVS

AutoM Click to go to the page. AutoM Auto Shaker Filter

This document is a preview generated by EVS

Rubber and plastics hoses Hose sizes, minimum and maximum inside diameters, and tolerances on cut-to-length hoses

This document is a preview generated by EVS

Eurocode 9 Design of aluminium structures

IMPROVEMENT OF RESIN IMPREGNATION INTO GLASS CLOTH BY SILANE TREATMENT IN RESIN TRANSFER MOLDING

PVC & PET FILMS FOR TOMORROW, TODAY.

UNE APPROCHE EUROPÉENNE POUR LES CO-PRODUITS INDUSTRIELS? Heribert Motz

WET POSITION BOOSTER FANS FOR REDUCED POWER CONSUMPTION AND OPTIMIZED ENVIRONMENTAL PERFORMANCE OF POWER STATIONS WITH FGD AND WET STACK

Flues and chimney systems

Medical gloves for single use - Part 2: Requirements and testing for physical properties

Forum for European Electrical Domestic Safety FEEDS. Residential Electrical Safety How to ensure progress?

Transcription:

16 TH INTERNATIONAL CONFERENCE ON COMPOSITE MATERIALS COMPOSITE CHIMNEYS Géza Kecskeméthy, István Kovácsay, [Balázs Zsigmond]: zsigmond@kompozitor.hu Kompozitor Co. Ltd., Hungary Keywords: life-saving chimney lining, brand-new FRP chimney, industrial chimney, chimney for incinerator, ventilation duct Abstract A lot of chimneys become dangerous because of corrosion. A composite chimney lining tube has been developed by Kompozitor Ltd. Its trade name is FuranFlex and it is inserted into the chimney to be repaired, blown up by steam then irreversible hardened. The composite tube with 2 mm wallthickness forms the shape, follows the path of the chimney. It is corrosion and heat resistant up to 220/350 C in flue gas. One of the advantages is that it can be used without breaking the wall as opposed to stainless steel. It is already used in 16 European countries in the diameter range of 60-900 mm until 80 m length. Over the above mentioned dimensions FuranFlex cannot be applied. A self supported, industrial chimney has been developed by Kompozitor Ltd for these large sizes. One has been already built with 1,250 mm diameter, 46.7 m height and 11,700 kg total mass in a hazardous waste incinerator environment. heating, modern, energy efficient boilers has affected the processes in chimneys radically. In the past century wood and coal were given up for the more economical oil and gas heating where the flue gas temperature does not even reach 250 C (in case of wood or coal heating this temperature is above 450 C). This, however, had tragic results for chimneys. An acidic condensate precipitates out of the flue gas and corrodes mortar, concrete and sometimes even stainless steal. Due to this corrosion, carbon monoxide may enter rooms, and hence causes several deaths every year. App. 300 people in France and app. 20 in Hungary die in carbon monoxide poisoning every year. A significant numbers of these cases are caused by wrong chimneys. In Fig. 1 an article about a Peruvian hotel can be seen where 57 people had to move to a hospital considering due to the suspicion of carbon monoxide poisoning caused by wrong chimneys. 1 Introduction Kompozitor Co. Ltd. established in Budapest, Hungary, 1991. The profile of the company is R&D and manufacturing new products and machines in the field of reinforced plastics. Our philosophy is Always unique solutions, never copying. In this paper two types of chimneys made of composite material are presented. 2 FuranFlex - Chimney Lining Technology For several thousands of years mankind had no problems with chimneys. Wood and coal were used for heating and cooking, where the temperature of the flue gas was 400-500 C. At this temperature all of the combustion products left the chimney in the form of steam or gas. Spreading of oil and gas Fig. 1 Carbon monoxide poisoning in a Peruvian hotel To avoid this dangerous situation all gas and oil heated chimneys must be lined against corrosion in Europe. The most common technique used is to insert corrosion-resistant tubes into the existing chimney. In this case the following unsolvable problems arise: 1

Géza Kecskeméthy, I. Kovácsay, [B. Zsigmond] Rigid, thick-walled (0.6 mm) stainless steel tubes are corrosion-proof (10 years guarantee), but it is impossible to insert them into a long, faulty, crooked chimney without joints and breaking the walls. Flexible thin-walled (0.3 mm) stainless steel tubes can be pulled into a non-linear chimney with inclination, but their resistance to corrosion is not satisfactory. The cross-section of the inserted lining tube is always smaller than that of the existing chimney. This can result in less draft and less efficient heating. The largest problem in the chimneys of gas and oil heating is corrosion. If one cubic meter gas is burnt, 1-2 liter water containing sulphuric, hydrochloric and nitric acid molecules as well is formed. Condensation occurs at 80 C. The more efficient is the boiler, the lower the temperature of flue gas is and the more condensate precipitates in the wall of the chimney. The acidity of this condensate is only ph 4-5 but its effect can be seen in Fig. 2 where these aluminum liner parts from the chimney were removed after 5 years of operation. Therefore industrial chimneys are designed in a way that the flue gas leaves the chimney over the dewpoint temperature (160-180 C) to eliminate condensation. However, much energy is wasted in this case. stainless steel liners (Fig. 3) which changes the field of chimney lining radically. The structure of the FuranFlex chimney liner can be seen in Fig. 4. Fig. 3 Conventional chimney liners Fig. 4 Structure of the FuranFlex The applied resin contains a lot of components, additives and is excellent heat- and fire-resistant, corrosion proof and environmental friendly. FuranFlex is delivered as a flat, soft, flexible tube (Fig. 5) folded into a compact pack less than 80 kg in a box (Fig. 6), and in case of bigger size (100-300 kg) in a wooden box. The matrix resin is in prepolymerized state, while the FuranFlex tube is tactile and not sticky, and can be stored under 18 C for several months. Fig. 2 Corroded aluminum chimney after 5 years of operation The inner layer is a polyolefin based, extruded tube, while the middle section is a glass fiber reinforced composite (pre-preg) layer followed by a synthetic fabric layer. The goal of the Kompozitor Ltd is to develop a composite chimney instead of aluminum, ceramic or Fig. 5 Folded FuranFlex tube Fig. 6 Packaging of the FuranFlex tube 2

COMPOSITE CHIMNEYS The FuranFlex technology consists of the following steps: Examination and cleaning of the chimney to be lined; Insertion of the cross part (T) into the wall; FuranFlex tube insertion into the chimney to be lined (Fig. 7.a); Closing the bottom and top part of the chimney with special devices; Connection of the steam generator at the bottom part of the FuranFlex tube; Blowing up the FuranFlex by steam at 0.2-0.4 bar pressure ; Hardening of the FuranFlex for 0.5-3 hours (depends on the diameter and length); Cutting off the ends of hardened FuranFlex ; Insertion of condensed water tank/cleaning part; Insertion of the rain-hood (if required). Table 1 Technical properties of hardened FuranFlex tube Property Value Wall thickness 2-5 mm Diameter 60-900 mm Permanent heat resistance 250-350 C Cold resistance -50 C Tensile strength 100-250 MPa Modulus of elasticity 12-15 GPa Corrosion resistance ph 1-pH 12 Environment protection Does not emit toxic materials between 20 and 1000 C Fig. 7 Installation of the FuranFlex tube (a); The hardened chimney (b) The completed, hardened FuranFlex chimney can be seen in Fig. 7.b. and its technical properties are summarized in Table 1. FuranFlex tube follows the path of the chimney (until 30 declination) and takes up the shape of its cross-section. A few examples for this can been seen in Fig. 8. FuranFlex can be used for conventional gravity chimneys, standard (overpressure) and high efficiency, condensing boilers up to 5000 Pa according to the newest European standard (EN 14471) concerning plastic flue gas systems. Fig. 8 Possible cross-sections of the FuranFlex in the chimney Here are some advantages of the FuranFlex : Heat and corrosion resistant Thermally insulating Good mechanical properties Perfectly gas-tight Follows the path of the chimney Variable diameters in a single chimney Available in any length, various cross-sections Needs no junctions Smooth inner surface Short installation time Easy to handle No wall-breaking 25 years guarantee Built-in quantity 850 km FuranFlex tube has been built till now in Europe. The longest one was 80 m (France) and the largest diameter was 900 mm (Ukraine). FuranFlex chimney lining system is exported by Kompozitor Ltd to European countries summarizes in Table 2. Table 2 Present exported European countries Austria France Romania Italy Belgium Netherlands Slovakia Sweden Norway Finland Spain Estonia Poland Ukraine Greek Russia 3

Géza Kecskeméthy, I. Kovácsay, [B. Zsigmond] There are few big partners in the given countries who have used FuranFlex for 5-7 years, and in some countries it is only started to be used. Licenses The introduction of FuranFlex (and all new chimney lining technologies as well) requires permit in all countries. This usually contains the following measurements: Permanent heat resistance Corrosion resistance Pressure-tightness Fig. 9 shows a cyclic-diagram of a standard heat resistance measurement for chimney liners, while Fig. 10 presents the testing laboratory. Fig. 11 Top and bottom pieces of the FuranFlex Fig. 12 Fastblower Fig. 9 Cyclic-diagram of heat resistance Fig. 10 Testing laboratory Installation devices of the FuranFlex Top and bottom closing pieces (Fig. 11) are used to pre-blow up the chimney, to carry in and out the steam and to remove the condensed water. The pre-blow up is carried out by a self-designed Fastblower (Fig. 12). A self-designed steam generator (36 kw performance, 93% efficiency) is applied for steam generation (Fig. 13). Fig. 13 FuranFlex KNK 36 type steam generator Quality assurance Courses are organized by Kompozitor Ltd for those who would like to use the FuranFlex technology. Fig. 14 shows the training chimney used in a course. Awards The FuranFlex material and technology won the following international awards: Throphées de l innovation, Intercliama, Paris Award Special, International building exhibition, Kiev (2004) 4

COMPOSITE CHIMNEYS Gold medal, Internationale Ausstellung Idéen, Erfindungen, Nürnberg (2004) Palmares de l innovation, Paris (2004) Genius Europa Grand Prix, International exhibition of inventions, Budapest (2004) Gold medal with mention, 53 rd world exhibition of innovation, Research and new technology, Bruxelles (2004) material is 2.5 times higher than that of the steel which could cause damage in the structure in the long run. Fig. 14 Training chimney Polykamin Industrial chimneys are also damaged by corrosion; e.g. the chimney of the hazardous waste incinerator of the French company, ONYX in Hungary. This chimney made of steel-plate (6 mm), with an abrasion- and corrosion-proof vulcanized inside rubber liner (5 mm), thermal-insulation (80 mm) and aluminum trapezoid plate (1.5 mm) as the outside cover. The inner diameter of the steel chimney was 1,100 mm. The total mass of the steel chimney was 18,000 kg. The the steel chimney can be found in Fig. 15.a. After 8 years operations steam and flue gas flew out the thermal insulation since corrosion tracks formed on the chimney wall (Fig. 15.b). The collapse of the chimney was a real risk. The first idea was to build and line a new steel chimney with FuranFlex technology, but it had to be rejected. On the one hand there was not any experience to line such a big chimney with FuranFlex technology. On the other hand the thermal-expansion-coefficient of the FuranFlex Fig. 15 Steel chimney (a), Steam escape (b) Therefore Kompozitor Ltd. Developed a selfsupported composite chimney (trade name: Polykamin). Polykamin corresponds to the following requirements: Permanent heat-resistance up to 125 C Excellent corrosion-resistance in ph 3 range High mechanical strength Abrasion-resistance UV-resistance Self-quenching property Vinyl-ester and isophtalic-acid polyester were applied when producing Polykamin. The raw resins were modified with different additives considering to the strict requirements and the processes in the chimney. Production data are shown in Table 3. Table 3 Production data Quantity of flue gas and steam 50,000 m3/h Reflowing condensed water 4,000 kg/h Acidity ph 5 Speed of the flue in the chimney 60 km/h Speed of the flue in the dropseparator 120 km/h The features of the Polykamin are summarized in Table 4. 5

Géza Kecskeméthy, I. Kovácsay, [B. Zsigmond] Table 4 Features of the Polykamin Inside diameter Length of the vertical tube Diameter of the water drop separator Height of the water drop separator Weight of the vertical tube Weight of the water-drop separator Weight of the elbow 1,250 mm 40.4 m 2,500 mm 5 m 9,300 kg 1,700 kg 700 kg Prefabricated parts of Polykamin The vertical section is produced with filament winding technology. Its lay-up corresponds to the requirements of operation. The joint of the parts assures a perfectly smooth inner surface of the pipe. The 90 degree elbow of the bottom part made of two parts glued and screwed together externally. The diameter of the water-drop separator is 2,500 mm. The 120 km/h velocity flue gas is forced to circular path in it thus the acidic water-drops are centrifuged. According to high abrasion load Kevlar fibers were also applied. The vertical section of the plastic chimney was inserted in one part together with the elbow (Fig. 16.a). This was 10,000 kg in total. The water drop separator was assembled later in 70 m height (Fig. 16.b). It was prepared according to new principals, the purpose of which is not to let acidic water drops into the environment, with the best effectiveness The disassembling of the steel chimney took 2 days, and the assemblage of the plastic chimney lasted for 2 days as well. Waste incinerator was in operation during the assembly, flue gas was exhausted through a temporary chimney. POLYKAMIN plastic chimney (Fig. 17) was commissioned in October, 2005. Kompozitor has taken a 30 year corrosion warranty for the assembled chimneys. Experiences: After one year of continuous operation neither corrosion, nor erosion signs were observed in the chimney. The water drop separator perfectly selects water drops; acidic rain has disappeared in the environment. Resistance of the chimney is lower than it was of the steel chimney, thus power consumption of fans has significantly decreased and quantity of burnt waste could be increased. Advantages of Polykamin A few advantages of PolyKamin are the follows: Heat and corrosion resistant Excellent mechanical properties Withstand for the abrasive and corrosive effect from high quantity condensate (~4,000 kg/h) Perfectly gas-tight Smooth inner surface Paintable 30 years guarantee Fig. 16 Elbow (a); Water drop separator (b) Fig. 17 Polykamin: the chimney of a waste incinerator (a); Scheme of the chimney (b) Applications of the Polykamin PolyKamin can be used for any industrial chimneys such as oil-refineries, (hazardous) waste incinerators and chemical companies. 6