Power Isolation Solutions. Arc Flash Prevention Starts Here

Similar documents
316 Stainless Steel TS 8 Enclosure. The most rugged TS 8 yet

Minimizing Arc Flash Hazards with Modular Disconnect Enclosures

Rittal roof-mounted fans

Protection for the Industry that Powers the Planet

Energy Efficient Enclosure Climate Control

Arc Flash Analysis. Arc flash hazard analysis is required to determine the risk to personnel, warn them of the

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet

How to reduce exposure to arc flash hazards

NFPA 70E Arc Flash Considerations for MV Equipment. By: Dominik Pieniazek, P.E. HV Engineering, LLC

Arc Flash Mitigation Solutions: A Proactive Approach To Arc Flash Risk

NFPA 70E. Electrical Safety in the Workplace. KTR Associates. Joseph Deane, PE. Engineering Solutions

Protection from Electric Shock and Arc Flash. Meeting OSHA Regulations and NFPA 70E Standards.

Control Panel with Across The Line Starters

The safe way to verify the absence of voltage.

VeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage

NFPA 70E Electrical Safety & Arc Flash Training

HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove

NECA S System Approach to Electrical Safety for NFPA 70E

Electrical Safety Compliance: NFPA 70E

IMPROVE SAFETY WITH ARC FLASH LABELING COMPLY WITH THE 2015 NFPA 70E REGULATIONS

VIDEO VISITATION APPLICATION: FUNCTIONS AVAILABLE:

Implementing an Energized Electrical Work Program. SESHA Hill Country Chapter. Brett Jay Davis, PE Zephyr Environmental Corporation

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

Centennial Energized Electrical Work Permit Instructions

Liebert CRV Warranty Inspection Check Sheet

Property risk solutions

Solicitation Requirements Matrix

Your Global Automation Partner. Minimizing Arc Flash Exposure in Industrial Applications. White Paper - W1000

NECA S System Approach to Electrical Safety for NFPA 70E

NECA & Salisbury Assessment Solutions Partnership

COMBUSTIBLE DUST SAFETY PROGRAM

WIN-PAK SE with VISTA Integration INTEGRATED SECURITY, VIDEO AND ACCESS CONTROL SOLUTIONS. A Winning Combination

GMS GRAPHICAL MANAGEMENT SYSTEM

SEL Arc-Flash Solutions

Case Study. Custom Solutions for High Arc Flash Incident Energy and. Interlocked Electrical Enclosures. Overview: iriss.com

Rittal Mini Data Centre Modular Safe Extend and Light

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Liebert InteleCool Warranty Inspection Check Sheet

Arc Flash Codes & Compliance: What You Need to Know to Deliver Both Protection and Performance

NFPA 70E Electrical Safety in the Workplace

PGR-8800 TECHNICAL FAQ

Arc Flash Protection Training - NFPA 70e Electrical Safety

6/23/ National Electrical Contractors Association and Intec, Inc.

Your Turnkey Solution for Mitigating the Hazards of Arc Flash Incidents in the Workplace

Liebert DataMate (1-3 Ton) Warranty Inspection Check Sheet

ThermoControl 0 C - 10 C - 20 C - 30 C

NFPA 70E Elevates Safety. with Heightened Risk Awareness

Liebert Small System MCD and PFH Condensers (1-5 Ton) Warranty Inspection Check Sheet

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS

Commercial and Light Industrial Fire Alarm Control Panel

PRODUCT BULLETIN. Rev. A Monitoring Station offering PN Rev. B as a direct replacement. OVERVIEW / DESCRIPTION

Liebert Xtreme Density Chiller (XDC) Unit Warranty Inspection Check Sheet

Architectural and Engineering Specification for a Security Management System. StarNet 2

COMPLIANCE without compromise SAFETY without sacrifice YOUR RESULTS MATTER

Medi-Kool Product Highlights: NEW 12 Volt 135 Degree Blanket Warming Cabinets 2, 4 and 8 Blanket Warming Cabinets

SEL Arc-Flash Solutions

Hot Work Policy. Department of Risk Management. 1. Purpose. 2. Authority. 3. Scope

IEEE Std IEEE Recommended Practice for Electrical Installations on Shipboard Safety Considerations

2019 Price List. Company Overview. Gateways. Super Gateways. paragonrobotics.com GW3 GW10

inet Now Live Monitoring

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

CU-02 with Senaco Plus

SETION EMERGENCY LIGHTING NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) (2006) Life Safety Code, 2006 Edition

CENTERLINE 2100 Motor Control Center (MCC) Doors and Units with Vertical Operating Handles

wireless. web-based. worthy of the name RACO.

Document Number: ELECTRICAL SAFETY ZSD-HMSAFESA Issue Date: July 4, 2017 Revision #: 3 Next Review Date: July 4, 2022

Compliance without compromise Safety without sacrifice

Quick Reference Guide

Promoting Electrical Safety through NFPA 70E Standards Adherence

Monitoring of Electrical Equipment Failure Indicators and Alarming

White Paper. NFPA 70E 2018 Edition Changes and Implications for. Personnel Performing Condition Based Maintenance. Abstract: iriss.

For Complete Fire and Gas Solutions

LaserGuard2. Laser Collision Avoidance System. Part Number: R1 April 2015 Copyright 2015 Magnetek Material Handling

The Basics Arc Flash Protection

Regional Training. Seminar. » EasyPower Hands-On» Protective Device Coordination» Arc Flash Hazard Analysis. March 12-16, 2018 Austin, TX

PROTECTING YOUR PROPERTY INVESTMENT BEFORE DISASTERS OCCUR ARE YOU PREPARED?

Application Note on Reading the Vigilohm IM400 Insulation Monitoring Device Installed in Conext Core XC and XC-NA Series Inverters

Webinar November 12, 2014


Owner s Manual PS-200

SPECIAL SOLUTIONS. AE/PS EMC Enclosure Solutions... SPE 1-2. EMC Compatibility... SPE 3-4. Seismic/Zone 4 Applications... SPE 5-6

Electrical Safety Program

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

NFPA 70E Edition Update

Lock Out/Tag Out: Control of Hazardous Energy (LOTO) Environmental Health &Safety / Risk Management

What is an Emergency?

GasGard 100 Control System

Electrical Safety for Facility Managers and Building Owners

Energy Storage Systems Fire Safety Considerations. Howard Hopper, FPE Regulatory Services Program Manager

Alarm Lock A Division of the Napco Security Group 333 Bayview Avenue Amityville, New York Phone (631) Fax (631)

University of Pennsylvania. Environmental Health and Radiation Safety (EHRS) X-ray Diffraction User Guide

BGH Series Hot Surface Ignition Control

SALISBURY ASSESSMENT SOLUTIONS

G-MAX IVS R123 Vibration Sensors Perimeter Intrusion Detection System

Installation and Operation Manual

LABORATORY FREEZE DRYERS ADVANCED PROCESSES

5000 Series Rack Panels

IR Viewing Windows and Arc Ratings Dispelling the myth of Arc-Resistant IR Viewing Windows

Dependable Solutions for Gas Detection

Instruction Manual December 2001 ENACOCU02

Transcription:

Power Isolation Solutions Arc Flash Prevention Starts Here

Arc flash prevention begins with Rittal The real-life issues of an arc flash incident When it comes to high-current electrical equipment, safety and machine up time are two of the most important considerations on the production floor. To lessen concern of these critical factors on engineers and service personnel, the brain trust at Rittal has developed a technology that minimizes the risk of arc flash explosions in the smart, highly engineered way that only Rittal can. 5 to 10 arc flash incidents occur every day in the United States 2,000 workers are admitted to burn centers per year for treatment of severe arc flash burns Arc flash incidents cause multiple deaths per year Medical treatment may cost $1.5 million or more 8-12 months of employee recovery time and the possibility of permanent disability Average litigation cost of $10 to $15 million dollars Rittal s Arc Flash Solution When considering safety and design flexibility during the planning stage, Rittal s Power solutions provide the capability to isolate high- and low-voltage equipment within the confines of their respective enclosure, assisting in compliance with NFPA 70E work place safety standards. Rittal s off-the-shelf power isolation solutions decrease the risk of personnel being exposed to arc flash and related injuries Rittal s solutions provide the capability to isolate low-voltage equipment and components used for programming, data acquisition, and system adjustment from high voltage components High-voltage line-side power is isolated within its own enclosure A partition wall serves as a barrier to high voltage line side power. 2 Rittal Power Isolation Solutions Rittal Power Isolation Solutions 3

An unlimited choice of low-voltage and high-voltage enclosure combinations. Customizable configurations and solutions from standard components provide a virtually unlimited choice of low-voltage (less than 50 volts) and high-voltage cabinet combinations to suit your specific application. Rittal s off-the-shelf solution minimizes the level of Personal Protective Equipment required to perform routine maintenance, especially when isolating (less than 50 volts) in its own enclosure. This control enclosure may also be disengaged from the interlock system to provide testing and diagnostic access while high-voltage equipment is energized. Accessories, such as external fold-down shelves, external data pockets, and interface flaps, allow for data retrieval, equipment monitoring, and routine maintenance to be performed externally to minimize exposure to arc flash hazards. Fold-down shelf Collapsible shelf designed to support programming and monitoring equipment. Locks in raised position and folds down when not in use. External data pocket Based on the popular AE wallmount enclosure, this data pocket is designed to hold system-related documents. Interface flaps, modular For universal use in all situations where rapid access to interfaces and sockets are needed. The enclosure remains closed and protected from ambient influences and unauthorized access. Interlocking door system ensures that the high voltage enclosure cannot be opened while disconnect switch is in ON position. For additional safety, all interlocked doors and master door must be closed in order to re-energize the enclosure. 4 Rittal Power Isolation Solutions Rittal Power Isolation Solutions 5

Explanation Height Width (add numbers) Depth TS 83 R 32C 40P 16R 20 Product Family Overall Height Rittal System followed by Control (Low Voltage) and Power (High Voltage) Suffix P=Power=High Voltage C=Control=Low Voltage (<50 volts) PC=Power and Control (High and Low Voltage) combined Width Overall Depth Partition Wall Barrier Between High-Voltage and Control Enclosure Control (Low Voltage) Enclosure (houses the Isolated Main) Two Door Enclosure (Control and Power Separate) Control (Low Voltage)/ (houses the Isolated Main) One Door Enclosure (Control and Power Combined) Overall HxWxD Control Voltage Enclosure High Voltage Enclosure PanelDimensions TS83R24C32P16R20 2100x1800x500 1900x500 1900x700 1900x300 TS83R24C40P16R20 2 Door Enclosure 2100x2000x500 1900x500 1900x900 1900x300 TS83R24C32P16R24 (1 Door Control Voltage; 2100x1800x600 1900x500 1900x700 1900x300 TS83R24C40P16R24 1 Door High Voltage) 2100x2000x600 1900x500 1900x900 1900x300 TS90R24C32P16R24 2300x1800x600 2100x500 2100x700 2100x300 Partition Wall Barrier Between High-Voltage and Control Enclosure Overall HxWxD High/Control Voltage Enclosure TS83R32PC16R20 2100x1200x500 1900x700 1900x300 TS83R40PC16R20 1 Door Enclosure 2100x1400x500 1900x900 1900x300 TS83R32PC16R24 (1 Door for High Voltage and Control Voltage 2100x1200x600 1900x700 1900x300 TS83R40PC16R24 Combined) 2100x1400x600 1900x900 1900x300 TS90R32PC16R24 2300x1200x600 2100x700 2100x300 Control (Low Voltage)/ (houses the Isolated Main) Two Door Enclosure (Control and Power Combined) Overall HxWxD High/Control Voltage Enclosure TS83R71PC16R20 2 Door Enclosure 2100x2200x500 1900x1700 1900x300 TS83R71PC16R24 (2 Doors for High Voltage and Control Voltage 2100x2200x600 1900x1700 1900x300 TS90R71PC16R24* Combined) 2300x2200x600 (1) 2100x900; (1) 2100x700* 2100x300 *(2) bayed enclosures for low/high voltage cabinet Control (Low Voltage) Enclosure Customizable Solutions Your customizable solution can be expanded to include the widths listed below. Contact your Rittal Distributor or local representative for a solution that meets your precise needs. Digit Available Options for 83 (2100 mm) Height Enclosure Available Options for 90 (2300 mm) Height Enclosure Product Family Overall Height Overall HxWxD Rittal System TS 83 R (houses the Isolated Main) Three Door Enclosure (Control and Power Separate) Control Voltage Enclosure Low Voltage 24C=24" 32C=32" 40C=40" 48C=48 63C=63 71C=71" High Voltage Enclosure High Voltage 32P=32" 40P=40" 63P=63 71P=71" 16R=16 TS83R24C71P16R20 3 Door Enclosure 2100x2800x500 1900x500 1900x1700 1900x300 TS83R24C71P16R24 (1 Door 2100x2800x600 1900x500 1900x1700 1900x300 TS90R24C71P16R24* Control Voltage; (1) 2100x700 2 Doors High Voltage) 2300x2800x600 2100x500 (1) 2100x900 2100x300 *(2) bayed enclosures for high voltage cabinet Overall Depth 24C=24" TS 90 R 32C=32" 40C=40" 48C=48" 32P=32 * 16R=16 24 *32 wide enclosure required; additional 32, 40, or 48 wide enclosures can be bayed to expand overall width 20 24 6 Rittal Power Isolation Solutions Rittal Power Isolation Solutions 7

Enclosures Power Distribution Climate Control IT Infrastructure Software & Services 03/14 US288 Rittal Corporation Woodfield Corporate Center 425 N. Martingale Road, Suite 400 Schaumburg, IL USA 1 Rittal Place Urbana Ohio 43078 USA Phone: 937-399-0500 Fax: 800-477-4003 Toll-free: 800-477-4000 Email: rittal@rittal.us Online: www.rittal.us