Unvented Roof Summary Article

Similar documents
Measurement of Attic Temperatures and Cooling Energy Use in Vented and Sealed Attics in Las Vegas, Nevada

Unvented Roof Assemblies for All Climates by Chris Schumacher

Air Distribution Fan and Outside Air Damper Recycling Control

Systems Engineering Approach to Development of Advanced Residential Buildings

2006 Building Science Press All rights of reproduction in any form reserved.

Understanding Ventilation in Hot Humid Climates by Joseph Lstiburek

Design Methodology and Economic Evaluation of Central-Fan-Integrated Supply Ventilation Systems

Results of Advanced Systems Research: Supplemental Humidity Control Systems

Special Topics on Residential HVAC

2006 Building Science Press All rights of reproduction in any form reserved.

Building America Special Research Project: Space Conditioning Systems for High Performance Homes

Practical and Effective Approaches to Residential Ventilation for Production Builders

Time-Based Scheduling of Residential Ventilation

Attic ventilation options can be confusing to roofing contractors

Why Are Attics Insulated With Open-Cell Spray Foam So Damp? Martin Holladay Editor, Green Building Advisor

Moisture-Safe Unvented Wood Roof Systems

Insight. No Sweat. Condensation on ductwork and boots in hothumid and mixed-humid climates. By Joseph W. Lstiburek, Ph.D., P.Eng.

Insight. Cool Hand Luke Meets Attics. What we ve got here is failure to communicate By Joseph W. Lstiburek, Ph.D., P.Eng.

BSC Building America High Performance Homes: Today & Tomorrow. Peter Yost Senior Building Scientist

Laboratory Evaluation of Hybrid and Advanced Water Heaters: Performance Overview in Hot Humid Climate

Asparagus Response to Water and Nitrogen

Ice Dams: Formations and Fixes

Hot Water a Hot Commodity Better Buildings by Design, February 2012 Burlington, VT

Air Change, Ventilation, and Dehumidification for Multi-family Buildings

Storing excess daytime solar energy to heat greenhouse at night!

Food Control Plans or National Programmes Cold Hold Records 2019

On Balance: Heat Rejection Control a Packaged Solution

BEST PRACTICE FOR THE LOCATION OF THE AIR AND THERMAL BOUNDARIES IN SMALL COMMERCIAL BUILDINGS

New Construction Builders Challenge: Sealed Attic and High Efficiency HVAC in Central Florida: A Year in Review

Insight Duct Dynasty 1

BALTIMORE GAS AND ELECTRIC COMPANY (BGE) Home Performance with ENERGY STAR Program. Rebate and Incentive Instructions

Copyright 2003 IBACOS, Inc. All rights reserved.

Energy Efficient Measures That Add Little or no. Program Lights & Appliances: How To Benefit from the Low-Hanging Fruit

What is Energy Star?

Using a Pressure Pan To Diagnose Duct Leakage

Ice Dam Symptoms and Solutions for a Cold-Climate Roof

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

Westinghouse UK AP1000 GENERIC DESIGN ASSESSMENT Resolution Plan for GI-AP1000-IH-01 Internal Fire Safety Case Substantiation.

Building Envelope Air Leakage Failure in Small Commercial Buildings Related to the Use of Suspended Tile Ceilings

In 1986, Pulte Homes in Tucson was

Overview. Case Study 2008 Building America Prototype ICI Showcase House. Daytona Beach, Florida. Project Team: ICI Homes, Building Science Corporation

Kimberly Rollins, Professor, Department of Economics, University of Nevada, Reno

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

Continuous Commissioning: A Valuable Partner to Retrofit Projects

IES Whole-Building Energy Model Baseline Energy Model Input/ Output Report. East Liberty Presbyterian Church East Liberty Presbyterian Church

Gambrel or Mansard Roofs and Ice damming

Free cooling on RTAF Chiller. Integrated option

MEASURED PERFORMANCE DATA FOR

NAHB Green Home Building Guidelines. 3.1 Prerequisites. ResCheck. Energy Efficiency

Sivu 2/8 Rate data Description Suomi Shut off times total 0.0 h/day Weekends with shut off times yes Daytime rate of heat pump Time for daytime rate 5

Attic Condensation. Presented by: Joan Maisonneuve Technical Services

Energy Effcient Home Construction

Bench Top Production Hydroponic Production

Performance of Solar Water Heating Systems in the United States

Air Distribution Systems in Conditioned Spaces i.e. Ducts in Unvented Attics

Strategies for Summer Utility Savings. Residential Environmental Program Series May 15, 2013

Residential Air Leakage (Blower Door) Testing for Florida Code Compliance

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

Ventilation in Humid Climates: Data from Field Experiments

announcements 4/10/08

RECOMMENDATIONS FOR 15% ABOVE-CODE ENERGY EFFICIENCY MEASURES FOR RESIDENTIAL BUILDINGS

2016 Title 24 HVAC Topics. June 4, 2013

WHAT S CHANGED WITH ANSI/RESNET/ICC STANDARD 380. Iain Walker, Residential Building Systems Group

Measurement of Ventilation and Inter-zonal Distribution In Single Family Homes

Effects of Air Conditioner Sizing on Energy Consumption and Peak Demand in a Hot-Dry Climate

4/8/2015 Item #10D Page 1

R4 Ventures LLC White Paper

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Heat Pumps and Public Swimming Pools, a Perfect Match

QUALITY. Task Force. Shifting from Corn Drying to Corn Storage. Dirk E. Maier, Agricultural Engineering. Average Temperature F

Analogue to Digital Telecare. Technical Advisory Board. 21 st June 2017 Work Stream 3 Procurement

Insulating Unvented Attics With Spray Foam

Transfer Station Recycling Update SWANA Technical Session-Waste Diversion 4 2/24/2017 2/28/2017

Acknowledgement: Ralph Prahl, Prahl & Associates, contributed critical review and analysis

URBAN DESIGN LONDON TRAINING PROGRAMME UDL are pleased to present our programme for April 2013 to March 2014.

Indoor Environmental Quality

Rt 29 Solutions Hydraulic Planning Advisory Panel. September 14, 2017

WHITE PAPER.

INEEL (1500) [45] 5.6 C 217 mm 60. Precipitation (mm) Temperature (oc) Month

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Euro-style Range Hood ESH5200

HOME PERFORMANCE ENERGY ANALYSIS

Biosolids Dewatering, Monitoring, and Disposal Programs

Heat Consumption Assessment of the Domestic Hot Water Systems in the Apartment Buildings

SnuggPro DATA COLLECTION FORM

97.501B. Prepared by: (415) Sponsored By: Final Report. Author: Presented at: ASHRAE. Meeting SF Me!

Comparative Summer Thermal Performance of Finished and Unfinished Metal Roofing Products with Composition Shingles

Insight. Venting Vapor. By Joseph W. Lstiburek, Ph.D., P.Eng., Fellow ASHRAE

WHAT S UNDER YOUR ROOF?

Water Heater Innovations Marathon Water Heater Limited Warranty Policies & Procedures

Monthly Report for January 2016

New Westminster Downtown Parking Strategy Public Open House #1 September 13, 2012

RESULTS FROM HOUSE APPLIANCE SAFETY AND DEPRESSURIZATION TESTS CONDUCTED ON SINGLE FAMILY HOUSES UNDERGOING SOUND INSULATION

ACCA Quality Homes ACCA 12 QH 2011 (Existing Home Evaluation and Performance Improvement) Developed in cooperation with RESNET

Rater Provider Monthly Webinar REM Rate Modeling Tips March 23rd 2013

about your house Attic Venting, Attic Moisture, and Ice Dams Figure 1 Typical attic floor insulations

ENERGY CONSUMPTION OF HOUSES AND LIFESTYLE IN COLD CLIMATIC AREA OF JAPAN

McQuay. Aircon Air Cooled Condenser. AMB, APB AMD, APD Vintage A. Last Manufacture: 1978

Evaluate your insulation. Look for a tag in the attic that shows the R-Values of insulation in the floors, walls and ceiling.

Welcome to the. Open House

RESNET ANNUAL CONFERENCE FEBRUARY 17, ENERGY STAR for Homes: The Road Ahead

Transcription:

building science.com 2008 Building Science Press All rights of reproduction in any form reserved. Unvented Roof Summary Article Research Report - 0301 2003 Kohta Ueno Abstract: This article was written to tie together and summarize the various papers on unvented conditioned cathedralized attics found on our website. We realize that there is a wealth of information, and much of it too detailed to understand or digest in a single sitting. Furthermore, building officials might not have the time available to carefully examine the many documents on the page; this is meant to summarize the main arguments, and provide pointers to where detailed information and measured data can be found.

Unvented Roof Summary Article Kohta Ueno,, 2003 (Revised links 2009) This article was written to tie together and summarize the various papers on unvented conditioned cathedralized attics found on our website. We realize that there is a wealth of information, and much of it too detailed to understand or digest in a single sitting. Furthermore, building officials might not have the time available to carefully examine the many documents on the page; this is meant to summarize the main arguments, and provide pointers to where detailed information and measured data can be found. The articles dealing with unvented roofs are as follows (in chronological order): Measurement of Attic Temperatures and Cooling Energy Use In Vented and Sealed Attics in Las Vegas, Nevada Armin F. Rudd, Joseph W. Lstiburek and Neil A. Moyer; Presented at the 96 Excellence in Building Conference, 14-17 November, and published in EEBA Excellence, The Journal Of The Energy Efficient Building Association, Spring 1997. Energy Efficient Building Association, Minneapolis, MN (http://www.buildingscience.com/documents/reports/rr-9701-measurement-of-attic-temperatures-andcooling-energy-use-in-vented-and-sealed-attics-in-las-vegas-nevada/view?topic=/doctypes/researchreport) Vented and Sealed Attics In Hot Climates, A. F. Rudd and Joseph W. Lstiburek, Presented at the ASHRAE Symposium on Attics and Cathedral Ceilings, Toronto, June 1997. ASHRAE Transactions TO- 98-20-3. American Society of Heating Refrigeration and Air-Conditioning Engineers, Atlanta, GA. (http://www.buildingscience.com/documents/reports/rr-9801-vented-and-sealed-attics-in-hot-climates/view? topic=/doctypes/researchreport) Unvented-cathedralized attics: Where we ve been and where we re going, A. F. Rudd, Joseph W. Lstiburek, and Kohta Ueno. 2000. (http://www.buildingscience.com/documents/reports/rr-9904-unvented-cathedralized-attics-where-we-vebeen-and-where-we-re-going) Unvented Roof Systems, Joseph W. Lstiburek, 2001. (http://www.buildingscience.com/documents/reports/rr-0108-unvented-roof-systems/view?topic=/ doctypes/researchreport) Unvented Roofs, Hot-Humid Climates, and Asphalt Shingles, January 2003, Joseph Lstiburek. (http://www.buildingscience.com/documents/reports/rr-0306-unvented-roofs-hot-humid-climates-andasphalt-roofing-shingles) "Unvented Roof Assemblies or All Climates," Revised August 2008, Christopher Schumacher. (http://www.buildingscience.com/documents/digests/bsd-149-unvented-roof-assemblies-for-all-climates/?topic=/doctypes/digest) Unvented Roof Summary Article Page 1 of 1 2002

Unvented Roof (Conditioned Attics): Theory and Practice Building codes typically require attic ventilation; the origin of this requirement comes from cold climate demands to avoid ice damming and vent internally generated moisture. In hot (cooling-dominated) climates, the purpose of attic ventilation is to remove solar gain from the roof, thereby reducing the contribution of roof cooling load. In typical houses, the contribution of the roof cooling load to the total load is on the order of 10%. However, our modeling and research has shown that the requirement for venting attics in hot-dry and hothumid climates is of questionable validity. Our studies on houses in various locations (including Las Vegas, Tucson, and the southeastern United States) have shown that by moving the ceiling air barrier and thermal barrier to the roof plane, better building airtightness can be achieved, and that the elimination of heat gain to the attic ductwork (due to conduction and leakage) more than offsets the additional heat gain caused by not venting the attic. Placement of the air handler and ductwork system in this conditioned attic space negates the effect of duct leakage, which is commonly 10-20% of the rated air handler flow in typical construction. For houses with tile roofs, operating temperature for this conditioned attic or attic utility area, has been measured at typically within 5-7 F of indoor temperatures, without any direct space conditioning (i.e., conditioned by duct leakage and conduction); this provides less harsh operating conditions for the ductwork and air handler than typical unconditioned attics. An excellent (and entertaining) discussion of the basics is found in the article: Unvented Attic Discussion, 1999, Joseph Lstiburek. Detailed studies are also on the same web page: the paper that addresses both computer models and test houses is Measurement of Attic Temperatures and Cooling Energy Use In Vented and Sealed Attics in Las Vegas, Nevada. The paper Questions posed regarding unvented roofs provides a summary of typical questions on the performance and applicability of unvented roof systems. Unvented Roof Assembly Details (Air and Thermal Barriers) Moving the thermal and air barrier from the flat ceiling plane to the roof deck requires special detailing; since the attic is now conditioned space, it must be air sealed and insulated. Typical areas requiring draftstopping are the intersection between the conditioned attic and the unconditioned attic typically found over the garage or the porch. Details addressing these air barrier questions have been drawn and are enclosed here (see BSC Figures 1-4); they show the requirement for thermal barrier (i.e., insulation) and air barrier continuity around all of the conditioned space. BSC Figure 1 details the intersection between a conditioned attic and a perpendicular ridge overframed garage attic that is not conditioned; the detailing for an unconditioned porch roof would be similar. Figure 2 shows an intersection in-line with the trusses; it requires the construction of a kneewall with a rigid air barrier (such as plywood, OSB, rigid foam sheathing, or Thermo-Ply). Finally, in addition to this prescriptive detailing, the houses should be subjected to a blower door test protocol, with the attic hatch open, which tests the airtightness of the entire building shell, including the unvented roof. This test truly determines whether the air barrier details, taken in aggregate, are effective. We recommend the airtightness goal used in the Building America program; see the web page->building America -> Performance Targets. The airtightness goal is based on the surface area of the building, and is tighter than the majority of typical residential construction. Of course, controlled mechanical ventilation is a recommended addition to all houses. Unvented Roof Summary Article Page 2 of 2 2002

Unvented Roof Assembly Material Performance One of the first questions brought up when unvented roof systems are proposed is whether it will be detrimental to the life of the building materials in the assembly. In addition to measuring the energy performance of test houses in various locations, also measured temperatures of attic air, roof sheathing (plywood/osb), and roof tiles or shingles. The resulting data showed that when a vented tile roof in Las Vegas was compared with an unvented cathedralized roof, the maximum roof sheathing temperature difference was 17 F (see Questions posed regarding unvented roofs ). The maximum measured roof sheathing temperature of 154 F for the unvented attic was well within acceptable temperature limits (less than 180 F) (see Unventedcathedralized attics: Where we ve been and where we re going ). Furthermore, Las Vegas would be among the worst case locations for elevated temperatures of building materials (108 F ASHRAE 0.4% design temperature); few locations (e.g. Phoenix) have design conditions worse than that location. The air handler and HVAC system (ductwork) are operating at much less stressful temperatures (within 3-5 F of indoor setpoint, instead of typical attic temperatures), and no ultraviolet light enters via roof vents. These factors will tend to increase lifespan of this mechanical equipment and ductwork systems in unvented roofs. Unvented Roof Summary Article Page 3 of 3 2002

Climate Data As mentioned in Questions posed regarding unvented roofs, unvented attics with cathedralized insulation can be recommended in the continental US wherever the monthly average outdoor dry bulb temperature does not fall below 45 F; this coincides with the definition of a hot-dry or hot-humid climate. This temperature limitation is a function of potential condensation problems within the roof assembly. The logic behind this decision is detailed in the web page Unvented Roof Systems. As mentioned in that article, unvented assemblies can be built in mixed or cold climates, but further detailing is necessary. At www.weather.com (The Weather Channel Web Site), monthly average temperature information is available, in order to determine climate location (cold, mixed, or hot zone). Data for Tucson, AZ is shown below; it shows a lowest monthly temperature averaging above 45 F: Tucson, AZ Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr Mean outdoor temp (F) 66 74 84 87 85 81 71 59 52 52 55 59 66 Tucson, AZ Average Monthly Temperatures Temperature (F) 100 90 80 70 60 50 40 30 20 10 0 April May June July August Mean monthly outdoor temperature Condensing Temperature September October November December January February March April In addition, this data includes average precipitation records, which will allow the differentiation between humid and dry climate zones (i.e., over 20 inches/year or under). Tucson s historical data shows an average precipitation per year of ~13 inches (hot dry zone). Unvented Roof Summary Article Page 4 of 4 2002

Appendix I: Hygro-Thermal Regions Map Unvented Roof Summary Article Page 5 of 5 2002

Appendix II: Hot-Dry Wall Assembly From http://www.buildingscience.com/housesthatwork/hotdry/default.htm Materials 2 x 6 wood frame covered with one layer of building paper (#15 asphalt impregnated felt or 30 minute Type D), sheathed with one inch of expanded polystyrene and covered with stucco lath and 2-coat stucco. Framing 2 x 6 wood framing, 24 inches on center; for detailed information on advanced framing click here. (Shear load can be handled in any of several ways: diagonal bracing, OSB sheathing beneath the foam sheathing.) Moisture Control drainage plane continuity; flashing of penetrations and control of moisture laden airflow Flashing windows and doors should be flashed as shown in Figures 4-7. Unvented Roof Summary Article Page 6 of 6 2002

Unvented Roof Summary Article About the Author Kohta Ueno is an engineer at in Westford, Massachusetts. More information about Kohta Ueno can be found at www.buildingscienceconsulting.com. Direct all correspondence to:, 30 Forest Street, Somerville, MA 02143. Limits of Liability and Disclaimer of Warranty: Building Science documents are intended for professionals. The author and the publisher of this article have used their best efforts to provide accurate and authoritative information in regard to the subject matter covered. The author and publisher make no warranty of any kind, expressed or implied, with regard to the information contained in this article. The information presented in this article must be used with care by professionals who understand the implications of what they are doing. If professional advice or other expert assistance is required, the services of a competent professional shall be sought. The author and publisher shall not be liable in the event of incidental or consequential damages in connection with, or arising from, the use of the information contained within this Building Science document.