Operation Manual, Parts Directory and Price List

Similar documents
Operation Manual and Parts Directory

Operation Manual and Parts Directory

Operation Manual and Parts Directory

Operation Manual, Parts Directory and Price List

Operation Manual & Parts List. Slide Top Coolers Manufacture date beginning in 2009 and prior to March 27, 2017*

Mug Frosters and Plate Chillers*

Operation Manual, Parts Directory, and Price List

Operation Manual and Parts Directory

Front Venting Self-Contained Coolers*

Operation Manual, Parts Directory and Price List

Operation Manual. C1SL48 with compressor right, black vinyl-clad doors, and stainless top

Operation Manual, Parts Directory, and Price List

Front Venting Self-Contained Coolers*

Operation Manual, Parts Directory, and Price List

Operation Manual & Parts List

Vinfinity Wine Preservation System

GT-18, GT-18+1, GT-18+1L, GT-18+1R, GT-18+2, GT-18+2-IC Glasswashers (Manufactured after October 1, 1994 with motor driven drain stopper)

Operation Manual and Parts Directory

Bottle Disintegration System

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

RPI Industries, Inc.

InstructIon Manual KrEs EQuIPMEnt stands

BOTTLE COOLERS SLIDE TOP INSTALLATION AND OPERATION INSTRUCTION MANUAL MODEL SERIES BC24- BC36- BC48- BC72- BC96-

MODEL 925W FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET

WCPT-3 and WCPT-4. Effective Date: 2017 IMPORTANT INFORMATION READ BEFORE USE. Drop-in Display Cases

B a r Re f r i g e r a t i o n

RPI Industries, Inc.

Installation & Operation Manual

Installation & Operation Manual

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

INSTALLATION and OPERATION INSTRUCTIONS

INSTRUCTIONS FOR OPERATION AND CARE OF. P.O. Box 3527 City of Industry, CA, , U.S.A

INSTALLATION and OPERATION INSTRUCTIONS

Installation, Operation & Troubleshooting Instructions Pizza Table Refrigerator

Service Parts, Kits and Accessories

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

Wax Base Heater & Dispenser

e Bath Fan with Light User s Guide

OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901. Includes: Installation Use & Care Servicing Instructions

INSTALLATION and OPERATION INSTRUCTIONS

Ui REFRIGERATOR SPEC SHEET

INSTALLATION & OPERATING INSTRUCTIONS MODEL #17900 KEGERATOR MANUAL

ref. com Owner s Manual for models: A Step Above the Standard Thank you for choosing EVEREST

ELECTRICAL DATA: FEATURES: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET. 15 Width 7 Width

01550-RevG IMPORTANT INSTRUCTIONS WEBSITE MANUAL

e Heater/Exhaust Fan/Light User s Guide

RPI Industries, Inc.

Installation & Operations Manual for. BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers. 4/17 Rev.

INSTALLATION AND OPERATION INSTRUCTIONS STANDARD BACK BAR COOLERS, SELF CONTAINED MODEL NOS.

INSTALLATION and OPERATION INSTRUCTIONS

Installation & Operation Manual Ice Cream Freezers

MANUAL FOOD HOLDING & TRANSPORT CABINETS WITTCO MODEL NUMBERS

Professional Warming Drawer and Warming Drawer Cabinet

Installation & Operations Manual for R-290 SERIES. BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers 2/

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

INSTALLATION AND OPERATING MANUAL

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

INSTALLATION AND OPERATING MANUAL

RPI Industries, Inc.

INSTALLATION AND OPERATION INSTRUCTIONS CUSTOM BACK BAR CABINET SELF CONTAINED AND REMOTE

OWNER S MANUAL. Installation Operation Maintenance. Saturn Equipment

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

A PROUD HERITAGE OF EXPERIENCE & QUALITY. Beverage Cooler VT-SC-1

Reach-In Refrigerators and Freezers Service Manual

Technical Manual and Replacement Parts List. f Real Freezers

INSTALLATION AND OPERATING MANUAL

MODEL (Single Door) MODEL (2 Door pass through)

WARMING AND MERCHANDISING CABINET

Bottle Coolers. Manual for installation, use and Maintenance

BMG-HGP & BMG-SLP Model Bottom Mounted Full-Length Glass Door Refrigerator Merchandisers

INSTALLATION and OPERATION INSTRUCTIONS

OPERATING INSTRUCTIONS

BACK BAR REFRIGERATION Installation, Operation and Maintenance Instructions

Quality Refrigeration OWNER S MANUAL. Instructions for the installation, operation and maintenance of Traulsen: Heated Banquet & Transport Carts

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne.

Glass Washer. PERLICK Glass Washer NO ONE WORKS HARDER TO KEEP YOU COOKING. WHALEY FOODSERVICE REPAIRS ITEM PART NO. NO.

FOOD WARMING/MERCHANDISING CABINET

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

WARMING AND MERCHANDISING CABINET

INSTRUCTION MANUAL KBD DROP-IN PAN CHILLER

OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS

CRISP N HOLD FRIED FOOD HOLDING CABINET MODELS: CNH14, CNH18, CNH28, CNH40 OWNERS / OPERATORS MANUAL

Milk Coolers Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

POLAR TEMP XPORTABLE ICE MERCHANDISER SETUP MANUAL

Henny Penny Blast Chiller/Freezer Models BCC/BCR-140 Models BCC/BCR-175 Models BFR/BCR-350

COMFORT PACK INSTALLATION AND MAINTENANCE INSTRUCTIONS

e Bath Fan with Light User s Guide

Xaact Spot. Xaact Hot Spot

Before Putting Into Use. Important. Tips for Energy Savings

Refrigerators. Technical Manual and Replacement Parts List FORM NO REV H MODEL SKTTR7FW MODEL SKC1220W

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50

OPERATING INSTRUCTIONS

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

Service Manual Models CPH2 & CPH3

11 0 Wo o d c r e s t R o a d, C h e r r y H i l l, N J For Models: VR-1, VR-2, VR-3 VF-1, VF-2, VF-3

OPERATIONS MAINTENANCE MANUAL

Refridgerated Topping Rail Model: RTR-8 Intended for other than household use. Unit must be kept clear of combustibles at all times.

Transcription:

Operation Manual, Parts Directory and Price List Vertical Door Coolers* A Family Company Manufacturing In The USA Since 969 Self-Contained Models - BB, BB36, BB60, BB8, BB08, ND5, ND7, ND9, FV, FV8, LP60, LP8, LP08, PT60, PT8, PT08, KC, KC8, KC5, KC7, KC8* Remote Models - BB, BB8, BB7, BB96, LP8, LP7, LP96, PT8, PT7, PT96 Dry Storage Models - DS, DS8, DS7, LPDS *See Page for Important Cooler Serial Number Information BB60-L-XSH(LR) FV-BS(L) BB7-R-N(LLR) shown with optional wood panel doors PT60-L-LLH(LR/RL) Glastender, Inc. 500 North Michigan Road Saginaw, MI 860-9780 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com Rev.0--8 008 Glastender, Inc.

Service and Parts Cooler Serial Number Information... Terms and Conditions... 3 Warranty... Installation Introduction... 5 Utility Requirements and Connections... 5 Uncrating and Start-Up Instructions... 5 Operation... 5 Cleaning Instructions...5-6 Floor Sealing Instructions... 6 BB Minimum Air Flow Clearance Diagram... 6 Cooler Installation Checklist... 7 Cooler Design Change... 8 Specifications Electrical and Refrigeration Specifications... 9 Wiring Diagrams... 0- Endwall Models... 0 Self-Contained Models... Remote Models... Remote Models with Solenoid Control... 3 Built-in Fluorescent Light Fixtures... 3 BB Self-contained and KC Models... Replacement Parts Compressor and Condenser Related Parts... 5- BB Self-Contained & KC... 5 BB36... 6 LP60, LP8, LP08, and Non Endwall BB60, BB8, BB08, ND5, ND7, ND9, KC7, and KC8... 7 BB36, BB60, ND5, and KC5 Endwall... 8 BB8, BB08, ND7, ND9, KC7, and KC8 Endwall... 9 KC8... 0 PT60, PT8, PT08... FV and FV8... Evaporator and Related Parts... 3-5 Doors and Related Parts... 6-9 Shelving, Racks and Related Parts... 30 Refrigeration Compartment Covers... 3 0 Volt Electrical Parts... 3-33 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com

Cooler Serial Number Information BB & ND Self-Contained Cooler Serial Number Information This manual is specific to self-contained BB60, BB8, BB08, ND5, ND7, and ND9 coolers prior to the serial numbers and dates listed below. BB60R 3363F 0/6/09 BB60L 35F 03/03/09 BB8R 357F 03/0/09 BB8L 356F 03/0/09 BB08R 35F 03/0/09 BB08L 36F 0/7/09 ND5R 359F 03/09/09 ND5L 3559F 03//09 ND7R 3906F 0/08/09 ND7L 375F 03//09 ND9R 36F 0/09/09 ND9L 375F 06/0/09 FV Cooler Serial Number Information This manual is specific to self-contained FV coolers prior to the serial numbers and dates listed below. FV SN 33788F and excluding SN 3753F & SN 33F 05-3-3 FV8 SN 33788F and excluding SN 3796F 05-3-3 LP Self-Contained Cooler Serial Number Information This manual is specific to self-contained LP coolers prior to the serial numbers and dates listed below. LP60R SN 38786F 09-8-0 LP60L SN 38783F 09-8-0 LP8R SN 39050N 09-8-0 LP8L SN 3877N 09-8-0 LP08R SN 33070N 09-8-0 LP08L SN 3906N 09-8-0 PT Self-Contained Cooler Serial Number Information This manual is specific to self-contained PT coolers prior to 07 and serial number 3699. BB, ND, LP, PT Remote Cooler Serial Number Information This manual is specific to remote BB, BB8, BB7, BB96, ND0, ND60, ND80, LP8, LP7, LP96, PT8, PT7, and PT96 coolers prior to 07 and serial numbers 3699 & 0699. KC Cooler Serial Number Information This manual is specific to self-contained KC8 coolers with serial numbers beginning with 0 and prior to 07 and serial number 3699. 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com

Terms and Conditions Prices: All prices are LIST. Applicable taxes will be added. Quotations: Unless otherwise stated, quotations are effective for 30 days only. Acceptance: All orders are subject to acceptance by Glastender, Inc. s headquarters in Saginaw, Michigan. Possession of the Product Directory and Price List is not an offer to sell. Shipments: F.O.B. factory in Saginaw, Michigan. Freight terms are Third Party or Collect if shipped directly to you. Prepay and Add to Invoice freight terms are available upon request. The approximate shipping weights of all products are listed with the prices. Partial shipments will be made unless otherwise specified by the customer. Surface freight classifications are: GT-/GT-30/GW Glasswashers - Class 75 GT-8 Glasswashers - Class 50 All Underbar Equipment - Class 75 Bar Die Orders Class 50 Portable Bars - Class 75 Remote refrigerators (i.e., no compressor) or dry storage back bar equipment - Class 75 Self-contained refrigeration equipment - Class 50 Ice Display Units (IDU and GDU) - Class 85 Lighted Liquor Displays - Class 85 Beer line chillers and beer towers (beverage dispensing equipment) - Class 9.5 Bottle Disintegration System - Class 50 Ice Cream Freezers - Class 77.5 All small items are evaluated to see the most cost effective means for shipment. Many small items ship via UPS or FedEx; however, when dimensional weight is excessive, LTL carriers are the most cost effective choice. Spare parts orders received before :00 PM EST can usually be shipped the same day. The order department is happy to assist with routing or shipping questions. Delivery: The majority of equipment is manufactured to order and typically ships within three to six weeks after complete order information is received by the factory. In-stock equipment typically ships within two to three days of the factory receiving complete order information. Returns: Items specified as Manufactured to Order are NOT returnable. A Return Authorization number must be issued by the factory in advance for any items that are returnable. The number MUST be noted on the outside of the returned package. Returns must be received within 90 days of the issue date. Shipping charges must be prepaid. A minimum 0% restocking charge will be applied to all authorized returns if received in new, unused condition in the original packaging. The above conditions apply to spare part returns, except spare part returns must be received within 30 days of original shipment for electronic or electrical parts or within 90 days for all other parts. Loss or Damage: For customer routed shipments, Glastender, Inc. is not responsible for any loss, damage, or delay of merchandise during shipment. Such transit claims must be filed with the carrier. Merchandise must be examined on arrival. If shortages occur, Glastender, Inc. must be notified in writing within five (5) days of delivery to honor any shortage claim. Glastender will assume responsibility for freight claims on Prepay and Add shipments but the customer must inspect freight and note any damage upon receipt. Failure to do so may result in losses at the customer s expense. Custom Orders: Custom orders must be paid in advance and are not subject to cancellation. Laminates: Some products include common, readily available plastic laminates of the customer s selection. There may be an additional charge if uncommon varieties are ordered. //7 Payment Terms: Cash should be included with all orders unless credit terms have been arranged. To establish credit, banking and trade references are required. A convenient credit application is available upon request. Payment via credit card is not our normal means of receiving payment. Visa and MasterCard will be accepted, but must be charged at the time of shipment. In addition, a payment via credit card for orders totaling more than $500 will incur a 3% convenience fee on the total transaction amount. 3 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com

Glastender, Inc. warrants all products to be free of defects in material and workmanship. One-year labor and parts warranty applies to all glasswashers, self-contained refrigeration models, and BDS model bottle disintegration units. In established areas, a start up is included with GT- and GT-30 model glasswashers. Warranty is effective for one year from the date of installation or up to 8 months from date of factory shipment, whichever occurs sooner. Glastender, Inc. will replace any part or assembly found defective under normal use and service. For warranty labor claims beyond 5 months from the date of factory shipment, proof of date of installation or occupancy must be provided. Authorization for labor must be obtained from Glastender within the warranty period and prior to the service being performed. Labor warranty applies to the United States and Canada only. Remote refrigeration models and beer line chillers include a one-year parts warranty only. There is no labor warranty on these products. Field replacement parts not covered under the original warranty include a 90-day part warranty from the date of installation. FOUR YEAR ADDITIONAL COMPRESSOR WARRANTY: Glastender will warrant to the original user the compressor for all selfcontained refrigeration models for an additional four years following the regular one-year warranty period. This plan applies to the compressor only. A completed warranty claim form MUST accompany all returned defective parts or assemblies. Upon request, a defective part or assembly must be returned to Glastender, Inc., Saginaw, Michigan, with all transportation and delivery charges prepaid. Warranty repairs or replacements will be shipped FOB factory in Saginaw, Michigan. Reimbursement for applicable freight charges covers ground service only. Glastender provides in-warranty repairs during a service company s regular working days and hours. There is no provision for payment of a premium rate during overtime hours. When warranty service is requested during other than normal working hours, the end user will be charged the premium portion of the overtime rate. The warranty covers substantiated travel expenses for up to hours / 00 miles round trip up to a maximum of $50. Any additional costs due to installations that require extra work, time, or travel to gain access for service are the sole responsibility of the equipment purchaser. Any exceptions to these travel and access limitations must be pre-approved by a factory representative. The warranty does not cover door gaskets, chemical tubing, pump squeeze tubing, and/or any equipment subjected to accidents, freight damage, alterations from the original design, improper power and/or plumbing hookups, improper chemical use, general misuse, or lack of routine required maintenance as determined by Glastender, Inc. Installation, normal control adjustments, general maintenance, correcting an installation error, or service calls that reveal the unit is functioning normally will not be reimbursed under warranty. Condenser coils on self-contained refrigeration products must be cleaned regularly. Failure to provide adequate air flow to a refrigeration unit will void the warranty. Glastender shall not be liable for loss of use, revenue, or profit, or for any other indirect, incidental, special, or consequential damage including, but not limited to, product spoilage or loss. This warranty is conditioned upon Glastender receiving notice of any defect subject to this warranty within sixty (60) days of its discovery by the end user or dealer. All products are warranted only for the initial place of installation. Removal of a product automatically terminates this warranty. Warranty Statement APPLICAE TO ALL PRODUCTS SOLD WITHIN THE UNITED STATES AND CANADA SECOND YEAR EXTENDED PARTS & LABOR WARRANTY: Glastender s one-year parts and labor warranty on self-contained refrigeration units, excluding beer line chillers, can be extended to two years with the purchase of a two year parts and labor warranty. Specify part number EWR ($50 net price) when ordering. EXPORT WARRANTY - One year parts only. EXCLUSION OF WARRANTIES EXCEPT AS PROVIDED ABOVE, GLASTENDER MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT. LIMITATION OF REMEDIES AND DAMAGES If Buyer makes a valid and timely claim as outlined above, Glastender s liability and Buyer s remedies under this agreement will be limited solely to labor charges authorized and/or replacement or credit, at Glastender s option, with respect to Products returned at Buyer s expense within thirty (30) days after warranty repair. GLASTENDER S LIABILITY WILL IN NO EVENT BE GREATER IN AMOUNT THAN THE PURCHASE PRICE OF THE RETURNED PRODUCTS. GLASTENDER WILL NOT BE LIAE UNDER ANY CIRCUMSTANCE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, LABOR COSTS EXCEPT AS COVERED UNDER OUR WARRANTY, LOST PROFITS OR THE LOSS OF PERISHAE PRODUCTS RESULTING FROM THE USE OF OR INABILITY TO USE OUR PRODUCTS OR FROM OUR PRODUCTS INCORPORATION INTO OR BECOMING A COMPONENT OF ANY OTHER PRODUCT. NEITHER PARTY WILL HAVE ANY NEGLIGENCE OR OTHER TORT LIABILITY TO THE OTHER, OR TO ANY THIRD PARTY, ARISING FROM ANY BREACH OF THIS AGREEMENT. GOVERNING LAW - JURISDICTION The terms and conditions of an order are to be governed and construed according to the laws of the State of Michigan, without regard to conflict of laws principles. Buyer hereby consents to the jurisdiction and venue of the courts located in Saginaw County, Michigan. No representative, distributor, dealer, or any other person is authorized to modify this warranty. This warranty replaces all other written or verbal warranties. NOTE: Glastender, Inc. s policy of constant quality improvement means that prices, specifications, and policies are subject to change without notice. Questions regarding this warranty should be directed to Glastender s Warranty Administrator. 0-9-7 IMPORTANT!! Attention Service Companies Please review the important warranty information on this page. If you believe a service call should be covered by the factory, please call the factory for authorization between 8AM and 5PM EST, Monday through Friday. 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com

Installation Introduction This manual describes the operational features of Vertical Door Coolers. Please review this information before attempting installation and operation. Long term, trouble-free service will follow if good housekeeping and maintenance procedures are followed. Thank you for selecting Glastender, Inc. products. Utility Requirements and Connections Electrical: 5 Volt AC, Phase, 60 Hz. A separate 5 Amp circuit is recommended. A 6-foot grounded cord and plug is included with self-contained models. Plumbing: Self-contained Models: Automatic condensate evaporator is included. No drain connection required. Remote Models: An external drain connection is required. Use the ten foot length of /" ID by 5/8" OD plastic tubing provided to run the drain line for condensate. The tubing should exit through one of the 3/" side knock-out holes. Self-contained Keg Coolers: The drain pain drain is pre-plumbed at the factory to stub out below the compressor compartment. A field connection to an external drain must be made from that point. Uncrating and Start-Up Instructions All models are shipped in one carton. These steps should be followed:. If legs or casters are included, bolt them to the base with the bolts provided.. Unwrap power cord from base if included. 3. Position unit and level and/or seal as required (see page and 3).. The evaporator drain pan on remote models must be plumbed to an external drain. All units with draft beer must be plumbed to an external drain (except model KC which includes an internal plastic drain bottle). On selfcontained models with draft beer and a factory installed finished top, the beer tower drain pan is plumbed through the cabinet and stubs out in the 3" space below the compressor compartment. Connection to an external drain must be made from that point. 5. Place shelves in desired location. 6. Plug into 5 volt AC outlet if a power cord is included. Remote models require electrical connections to be made by an electrician or remote refrigeration contractor. 7. Load with bottles or cans and allow time for products to cool. 8. Your Glastender equipment is now ready for use. Operation The operating temperature range is 36 F ( C) to 0 F (5 C). Self-contained models include an automatic defrost system. The refrigerator will defrost every six hours for approximately 0 minutes. Endwall coolers will defrost every four hours for approximately 5 minutes. During the defrost, the fan inside the cooler will remain on and the refrigeration system will turn off Cleaning Instructions Cleaning is essential to sustaining the integrity of your equipment and preventing corrosion. ESTIMATED CLEANING TIME: 5 to 0 minutes per unit daily, 5 minutes quarterly FREQUENCY: Daily cleaning of exterior & door gaskets. Quarterly cleaning of interior, including shelves. Cleaning Instructions continued on page 5 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com

Installation Cleaning Instructions continued from page 3 PROCEDURE:. A non-chlorine based cleaner or mild detergent and warm water applied with a soft cloth or sponge to all contact surfaces.. Immediately rinse off cleaning agent(s), using clean warm water, clean soft cloth or sponge. 3. Dry with a soft clean cloth, removing standing water as soon as possible. NOTES:. Never use hydrochloric acid, wire brushes, steel wool, scrapers, or chlorine based cleaners on stainless steel surfaces, since they will break down the passivity layer and allow corrosion to occur.. On stainless steel surfaces, you may use a soft bristle brush or Scotch-Brite pad for more stubborn stains. Always scrub with the direction of the grain. Follow with a thorough cleaning as described above. 3. Deposits from food preparation must be properly removed. Even hard water deposits will rust stainless steel, if not removed.. Repeated cleaning may dry up black-vinyl-clad steel (exterior) surfaces of the cooler. Armor All or similar product can bring back the shine. Apply the product to a cloth and then rub into the surface, rather than spraying it directly onto the black-vinyl-clad surface. 5. The cooler door gaskets are most often overlooked when cleaning. Failure to clean them regularly will lead to premature failure, since alcohol and moisture build-up breaks down the gasket material. Sealing Vertical Door Cooler to Floor To comply with NSF & health codes, the cooler base must be sealed to the floor using NSF listed sealant. Place a bead of sealant along outer edges of the base and remove excess with disposable towel. The floor sealing procedure does not apply to models that include legs or casters. COOLER DOOR MAGNETIC GASKET COOLER CABINET Side View of Cabinet FLOOR BEAD SEALANT " BASE BB Minimum Air Flow Clearance Diagram WARNING: COMPRESSOR FAILURE DUE TO RESTRICTION OR OCKAGE OF AIR FLOW WILL VOID WARRANTY. 7" COMPRESSOR COMPARTMENT 8" " 8" " /" MINIMUM CLEARANCE FOR AIR FLOW AIR FLOW 8 /" 0" SWING WILL CONTINUE IF NO CABINET TO IMPEDE Plan View EVAPORATOR HOUSING 80 SWING 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com 6

Installation Attention Installer: WARNING!! Failure to level this cooler WILL VOID THE FACTORY WARRANTY. Doors will not close properly causing damage to hinges, handles, and/or gaskets which will adversely affect the refrigeration systems. COOLER WITH 6" LEGS COOLER WITHOUT LEGS Cooler Installation Checklist Is the unit evenly and solidly supported, either upon legs, or flat on the base; check for high spots? If the unit was designed for legs, are they attached? Is the unit level at the base, from end to end? Do the doors open and close freely, without touching any other part of the unit in travel? Are there open holes to the outside of the cabinet which are not plugged or insulated? Are there obstructions of any kind to air flow into or out of the condensing unit? Is product tubing or are other lines installed in such a manner to not allow shelf access? Special Instructions for Keg Coolers Before you begin:. Disassemble the tower into three parts, stiffener, skin, and top plate, top plate by unscrewing the top two screws.. Mount the column stiffener with provided four /"-0x-/" bolts. 3. Install insulation provided into the bottom of the column stiffener.. Place the column skin over the stiffener. Run the beer lines through the hole at the same time. 5. Install insulation provided into the top of the tower assembly. stiffener skin 6. Mount the column top plate to the column stiffener with the two #0-3x/" phillips flat head s/s machine screws provided. 7. Apply a bead of silicone sealant around the perimeter of the column. Use your finger to smooth out the bead. 8. Wash tapping device and faucet with detergent and water. Flush beer tapping device and faucet lines. 7 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com

Cooler Design Change Important Design Change Information In February 00, Glastender released new BB and ND self contained cooler designs with the evaporator housing moved into an area above the compressor compartment. The serial numbers for these units will be 90000 and above. As of September 006, KC5, KC7, and KC8 model keg coolers are being manufactured as endwall models. Due to special customer request some BB and ND self contained models may not have the endwall design. Please be sure to verify which cooler design type you are ordering parts for. The term endwall will be used throughout this document to denote parts used for coolers featuring this design. Standard cooler configuration with evaporator inside cooler area. Compressor compartment may be located left or right. Endwall cooler configuration (most BB and ND models manufactured after Feb. 00, most KC models manufactured after Sept. 006) with evaporator located in housing above the compressor compartment. Compressor compartment may be located left or right. 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com 8

Electrical and Refrigeration Specifications BB Self-contained & KC Manufactured //06 to 3//7 Electrical Refrigerant Pressure P.S.I.G. 5V, phase, 60 Hz Type Charge High Low.0 full load amps, /6 HP R3a 5.0 oz. 00 85 KC Manufactured Before //06 Electrical Refrigerant Pressure P.S.I.G. 5V, phase, 60 Hz Type Charge High Low.8 full load amps, /6 HP R3a 5.0 oz. 00 85 FV, FV8, and BB36 Self-contained Models Manufactured Before /0 Electrical Refrigerant Pressure P.S.I.G. 5V, phase, 60 Hz Type Charge High Low 5. full load amps, /5 HP R 3.5 oz. 85 BB Remote, BB8, BB7, BB96, LP8, LP7, LP96, PT8, PT7, PT96 Electrical Refrigerant Pressure P.S.I.G. 5V, phase, 60 Hz Type Charge High Low R n/a n/a n/a LP60, LP8, LP08 & Non-Endwall BB60, BB8, BB08, KC8, KC7, & KC8 Electrical Refrigerant Pressure P.S.I.G. 5V, phase, 60 Hz Type Charge High Low 8.8 full load amps, /3 HP R 3.5 oz. 85 PT60, PT8 Electrical Refrigerant Pressure P.S.I.G. 5V, phase, 60 Hz Type Charge High Low 8.8 full load amps, /3 HP R0a 9.0 oz. 85 PT08 Electrical Refrigerant Pressure P.S.I.G. 5V, phase, 60 Hz Type Charge High Low 8.8 full load amps, /3 HP R0a 0.0 oz. 85 BB36, BB60, ND5, KC5 Endwall Models Electrical Refrigerant Pressure P.S.I.G. 5V, phase, 60 Hz Type Charge High Low 7. full load amps, /3 HP R3a *.0 oz. 86 88 *.0 oz. charge Serial #3-06565-F and after. 0.0 oz. charge prior to Serial #3-06565-F. BB8, BB08, ND7, ND9, KC7, KC8 Endwall Models Electrical Refrigerant Pressure P.S.I.G. 5V, phase, 60 Hz Type Charge High Low 0. full load amps, /3 HP R0a 6.0 oz. 33 7 9 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com

Wiring Diagram for BB36, BB60, ND5, & KC5 Endwall Models WHITE LIGHT RECEPTICAL AUX. RECEPTICAL DEFROST TIMER WHITE ACK EVAPORATOR FAN 3 ACK LIGHT SWITCH UE WHITE UE UE MAIN POWER SUPPLY CORD ACK WHITE GREEN WHITE UE 5v AC 5amp CONDENSER FAN ACK ORANGE ACK WHITE OVERLOAD COMMON RUN START RELAY STARTER ACK ORANGE THERMOSTAT COMPRESSOR Wiring Diagram for Models BB8, BB08, ND7, ND9, KC7, & KC8 Endwall Models WHITE LIGHT RECEPTICAL AUX. RECEPTICAL DEFROST TIMER ACK WHITE EVAPORATOR FAN 3 ACK LIGHT SWITCH UE WHITE UE UE MAIN POWER SUPPLY CORD ACK WHITE GREEN WHITE UE 5v AC 5amp CONDENSER FAN ACK ORANGE ACK WHITE OVERLOAD COMMON RUN START RELAY STARTER ACK ORANGE THERMOSTAT COMPRESSOR 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com 0

Wiring Diagram for Self-Contained LP60, LP8, LP08, PT60, PT8, PT08, & Non Endwall BB36, BB60, BB8, BB08, ND5, ND7, ND9, KC8, KC7, KC8* *NOTE: See page 7 for endwall BB, ND, and KC self-contained model wiring diagrams Evaporator Assembly Note: Some Units May Have Two Fans (Three Fans Shown) 3 5 B B W S B ITEM 3 DESCRIPTION EVAPORATOR FAN ADE EVAPORATOR FAN MOTOR LIGHT SWITCH B 3 B W S 5 B W 5 5 6 7 CABINET LIGHT RECEPTACLE THERMOSTAT DEFROST TIMER OVERLOAD 3 8 9 CAPACITOR COMPRESSOR B W 0 START RELAY 5 VOLT 5 AMP SERVICE RECOMMENDED O O CONDENSER FAN MOTOR CONDENSER FAN ADE 3 BALLAST TOMBSTONE 5 STARTER B W G G O LEGEND M B = Black = Blue W = White O = Orange G = Green W 6 B O G W B 7 8 G 9 S W C M ELECTRICAL RATINGS All wires are 6 Gauge M 0 Compressor Condenser Fan Motor Evaporator Fan Motor 5V 5V 5V 7.05 AMP.80 AMP.8 AMP(Each) CONDENSING UNIT 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com

Wiring Diagram for Remote Coolers Including Models BB, BB8, BB7, BB96, LP8, LP7, LP96, PT8, PT7, PT96 Evaporator Assembly Note: Some Units May Have Two Fans (Three Fans Shown) 3 TO LIGHTS ITEM DESCRIPTION O O EVAPORATOR FAN ADE EVAPORATOR FAN MOTOR 3 LIGHT SWITCH THERMOSTAT 5 DEFROST TIMER G LEGEND 5V 5 O BK = Black = Blue W = White O = Orange G = Green R = Red Y = Yellow Y/ = Yellow w/blue stripe Y/R = Yellow w/red stripe M O NEUTRAL W ELECTRICAL RATINGS All wires are 6 Gauge C REMOTE CONDENSING UNIT Evaporator Fan Motor 5V.8 AMP(Each) O 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com

Wiring Diagram for Remote Coolers with Solenoid for Installing More than One Unit on One Condensing Unit Evaporator Assembly Note: Some Units May Have Two Fans (Three Fans Shown) 3 TO LIGHTS ITEM DESCRIPTION O O EVAPORATOR FAN ADE EVAPORATOR FAN MOTOR 3 LIGHT SWITCH THERMOSTAT 5 DEFROST TIMER G 5V 5 O O S W LEGEND BK = Black = Blue W = White O = Orange G = Green R = Red Y = Yellow Y/ = Yellow w/blue stripe Y/R = Yellow w/red stripe M ELECTRICAL RATINGS All wires are 6 Gauge NEUTRAL W Evaporator Fan Motor 5V.8 AMP(Each) Wiring Diagram for Models After /5/00 with Fluorescent Light System FLOURESCENT LIGHT SYSTEM TWO LIGHT FLOURESCENT LIGHT SYSTEM ONE LIGHT BK 5V R BALLAST Y/ LIGHT R R 5V B BALLAST STARTER B R B LIGHT R W W W Y/R LIGHT 3 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com

Wiring Diagram for BB Self-contained & KC 3/5/7 and After 0 VOLTS POWER CORD G M R C OL THERMOSTAT START RELAY S S COMPRESSOR OVERLOAD CONDENSER FAN MOTOR EVAPORATOR FAN MOTOR ALL WIRE 6GA. TOTAL. AMPS 0 VOLTS POWER CORD G W FAN TOWER COOLING MOTOR O M R C OL THERMOSTAT S START RELAY S COMPRESSOR OVERLOAD ELECTRICAL RATINGS COMPRESSOR,.7 AMPS ALL WIRE 6GA. W W W W M BB/KC WIRE DIAGRAM - 06009 LI N ACK FAN ORANGE POWER TIMER RED - FAN ACK - Wiring Diagram for BB Selfcontained & KC //06 to 3//7 KC Before //06 Wiring Diagram 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com

BB Self-contained & KC Compressor, Condenser and Related Parts Part No. Old Part No. Description Price. 06008990 /0 HP Embraco compressor, R3a $390.00 0600980 Start capacitor for /0 HP Embraco compressor.00. 060067 GT-030 Relay for /6 HP Aspera R3a compressor 5.00 0600979 Relay for /0 HP Embraco compressor 5.00 3. 06003 GT-0300 Overload protector for /6 HP Aspera R3a compressor 5.00 0600987 Overload protector for /0 HP Embroac compressor 5.00. 0600397 GT-033000 Automatic defrost timer 3.00 5. 06005 Condenser fan motor 5.00 6. 0900098 GT-0380 Condenser fan motor blade 5.00 06005 GT-0335 Beer tower cooling fan shroud (KC models 05/0-0//06) 7.00 06005 GT-0358 Beer Tower Cooling Fan Motor (KC models 05/0-0//06) 65.00 0600396 GT-03809 Exterior blade assembly (KC models 05/0-0//06) 0.00 0600395 GT-0380 Interior blade assembly (KC models 05/0-0//06) 5.00 7. 0700033 GT-0353 Condenser fan motor mounting bracket 0.00 8. 000000 GT-03608 Condenser coil (7" L, 6-7/8" H, -/" W) 30.00 0600389 GT-036 Static condenser coil (KC before 0//06) 5.00 9. 060008 Filter dryer with service port 5.00 0. 0600076 GT-038000 Condensate pan.00. 070003 Wicking material.00 050006 Wicking Material (KC before 0//06) 0.00. 0000 GT-03509 Cap tube 96" X.036 0.00 3. 060005 GT-0330 Thermostat with knob and plate [Selco] 50.00. 060063 GT-0389 Knob only 3.00 8 6 5 7 3 0 9 3 5 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com

Standard BB36 Compressor and Condenser Related Parts Part No. Old Part No. Description Price. 00008 GT-035005 /5 HP Aspera compressor, R $535.00. 0600379 GT-030 Start capacitor for /5 HP Aspera R compressor 0.00 3. 08000083 GT-0307 Relay for /5 HP Aspera R compressor 5.00. 08000069 GT-030 Overload protector for /5 HP Aspera R compressor 5.00 0600 GT-03507 /5 HP Tecumseh compressor, R (after /00) 90.00 060038 GT-03 Start capacitor for /5 HP Tecumseh R compressor 5.00 06005 GT-037 Relay for /5 HP Tecumseh R compressor 9.00 0600303 GT-03 Overload protector for /5 HP Tecumseh R compressor 5.00 5. 08000085 GT-03506 Condenser fan motor, 6W 35.00 6. 0800008 GT-0380 Condenser fan motor blade assembly 5.00 7. 06003 GT-0355 Condenser fan motor mounting bracket 5.00 8. 08000076 GT-0360 Condenser coil (0"L x 7-5/6"W x D) 0.00 9. 08000075 GT-03307 Fan shroud, condenser.00 0. 060008 Filter dryer with service port 5.00. 060068 GT-03800 Condensate pan (3-3/"L x 9-/"W x "D) 58.00. 070003 GT-0380 Wicking material ( required).00 3. 06006 Elbow, white nylon, /" x /".00. 060035 GT-0376 Tubing, drain, clear plastic, /" ID x 5/8" OD, per foot.5 5. 0800007 GT-0353 Base, condensing unit 30.00 6. 0600397 GT-033000 Automatic defrost timer, 6hr. 3.00 7. 060033 GT-0300 Condensing unit power cord 0.00 0000 GT-0377 Cap tube 60" X.036 0.00 8. 07000953 Accumulator, suction line 30.00 0 5 6 3 9 8 6 7 3 8 5 7 0 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com 6

Compressor and Condenser Related Parts for LP60, LP8, LP08, & Non Endwall BB60, BB8, BB08, ND5, ND7, ND9, KC7, and KC8 Part No. Old Part No. Description Price. 070007 GT-03500 /3 HP Aspera compressor, R $500.00. 0600379 GT-030 Start capacitor for /3 Aspera HP R compressor 0.00 3. 0600 GT-0303 Relay for /3 HP Aspera R compressor.00. 08000068 GT-030 Overload protector for /3 HP Aspera R compressor.00 06003 GT-03505 /3 HP Tecumseh compressor, R (after /00) 00.00 0600380 GT-0306 Start capacitor for /3 HP Tecumseh R compressor 0.00 0700068 GT-03 Relay for /3 HP Tecumseh R compressor 3.5 070008 GT-0307 Overload protector for /3 HP Tecumseh R compressor.00 5. 08000085 GT-03506 Condenser fan motor 35.00 6. 0800008 GT-0380 Condenser fan motor blade assembly 5.00 7. 06003 GT-0355 Condenser fan motor mounting bracket 5.00 8. 08000076 GT-0360 Condenser coil (0"L x 7-5/6"W x "D) 0.00 9. 08000075 GT-03307 Fan shroud, condenser.00 0. 060008 Filter dryer with service port 5.00. 060068 GT-03800 Condensate pan (3-3/"L x 9-/"W x "D) 58.00. 070003 GT-0380 Wicking material ( required).00 3. 06006 Elbow, white nylon, /" x /".00. 060035 GT-0376 Tubing, drain, clear plastic, /" ID x 5/8" OD, per foot.5 5. 0800007 GT-0353 Base, condensing unit 30.00 6. 0600397 GT-033000 Automatic defrost timer, 6hr. 3.00 7. 060033 GT-0300 Condensing unit power cord 0.00 06006 GT-0350 Cap tube 0" X.05 0.00 8. 07000953 Accumulator, suction line 30.00 9 6 8 3 8 3 5 7 /3 HP, R (BB60, BB8, BB08, ND5, ND7, LP60, LP8, LP08, KC7, KC8) 7 5 6 0 7 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com

BB36, BB60, ND5, & KC5* Compressor and Condenser Related Parts for Endwall Models Part No. Old Part No. Description Price. 060039 GT-0350 /3 HP Tecumseh compressor, R3a $35.00. 090008 GT-030 Start capacitor for /3 HP Tecumseh R3a compressor 0.00 3. 0900079 GT-03 Relay for /3 HP Tecumseh R3a compressor 0.00. 0900080 GT-03 Overload protector for /3 HP Tecumseh R3a compressor.50 5. 06009 GT-035 Condenser fan motor 00.00 6. 0800008 GT-0380 Condenser fan blade assembly 5.00 7. 060039 GT-035 Condenser fan motor mounting bracket 5.00 8. 08000076 GT-0360 Condenser coil 0.00 9. 08000075 GT-03307 Fan shroud, condenser.00 0. 060008 Filter dryer with service port 5.00. 0600055 Condensate pan 8.00. 070003 Wicking material.00 3. 0600350 GT-0373 Tubing, drain, clear plastic, per foot, 3/" ID 3.50. 0600085 GT-03539 Base, condensing unit.00 5. 060065 GT-03303 Automatic defrost timer hr. 56.00 6. 060033 GT-0300 Condensing unit power cord 0.00 0600673 GT-03809 Capillary tubing 8" X 0.036" (prior to Serial #3-06565-F) 0.00 0900057 Capillary tubing 65" X 0.09" (Serial #3-06565-F and after) 0.00 7. 07000953 Accumulator, suction line 30.00 * KC5 production began with serial number 309968N. 3 3 6 5 5 9 7 7 0 8 6 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com 8

BB8, BB08, ND7, ND9, KC7*, & KC8* Compressor and Condenser Related Parts for Endwall Models Part No. Old Part No. Description Price. 0700073 GT-035008 /3 HP Embraco compressor, R0a $50.00. 070005 GT-0303 Start capacitor for /3 HP Embraco R0a compressor 5.00 3. 0600675 GT-0303 Relay for /3 HP Embraco R0a compressor 5.00. 070007 GT-0305 Overload protector for /3 HP Embraco R0a compressor 5.00 5. 08000085 GT-03506 Condenser fan motor 35.00 6. 0800008 GT-0380 Condenser fan blade assembly 5.00 7. 060039 GT-035 Condenser fan motor mounting bracket 5.00 8. 0600393 GT-0369 Condenser coil 30.00 9. 08000075 GT-03307 Fan shroud, condenser.00 0. 060008 Filter dryer with service port 5.00. 0600055 Condensate pan 8.00. 070003 Wicking material.00 3. 0600350 GT-0373 Tubing, drain, clear plastic, 3/" dia, per foot 3.50. 0600085 GT-03539 Base, condensing unit.00 5. 060065 GT-03303 Automatic defrost timer hr. 56.00 6. 060033 GT-0300 Condensing unit power cord 0.00 0600676 GT-0380 Cap tube 8" x.09 0.00 7. 07000953 Accumulator, suction line 30.00 *KC7 Endwall configuration production began with serial number 003097N. *KC8 Endwall configuration production began with serial number 00309N. 3 3 5 6 5 9 7 8 7 0 9 6 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com

Compressor and Condenser Related Parts for KC8 Part No. Old Part No. Description Price. 070007 GT-03500 /3 HP Aspera compressor, R $500.00. 0600379 GT-030 Start capacitor for /3 HP Aspera R compressor 0.00 3. 0600 GT-0303 Relay for /3 HP Aspera R compressor.00. 08000068 GT-030 Overload protector for /3 HP Aspera R compressor.00 06003 GT-03505 /3 HP Tecumseh compressor, R (same models, after /00) 00.00 0600380 GT-0306 Start capacitor for /3 HP Tecumseh R compressor 0.00 0700068 GT-03 Relay for /3 HP Tecumseh R compressor 3.5 070008 GT-0307 Overload protector for /3 HP Tecumseh R compressor.00 5. 08000085 GT-03506 Condenser fan motor, 6W 35.00 6. 0900099 GT-03805 Condenser fan blade 0.50 7. 06000586 Condenser fan motor mounting bracket 9.00 8. 060039 GT-0368 Condenser coil (9"L x 7"W x 3-/"D) 75.00 9. 0600005 Fan shroud, condenser (prior to 9/6/06).00 0600853 Housing, condenser fan, 8" models (after 9/6/06).00 060085 Bracket, condenser fan, top, 8" models (after 9/6/06) 6.00 0600855 Bracket, condenser fan, bottom, 8" models (after 9/6/06) 6.00 0. 060008 Filter dryer with service port 5.00. 060065 GT-0380 Condensate pan (7-7/8"L x 7-/"W x -/"D).00. 070003 Wicking material.00 3. 06006 Elbow, white nylon, /" x /".00. 060035 GT-0376 Tubing, drain, clear plastic, /" ID x 5/8" OD, per foot.5 5. 0600397 GT-033000 Automatic defrost timer 6hr. 3.00 6. 060033 GT-0300 Condensing unit power cord 0.00 06006 GT-0350 Cap tube 0" X.05 0.00 7. 07000953 Accumulator, suction line 30.00 0 7 6 3 5 0 7 6 9 3 5 8 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com 0

Compressor and Condenser Related Parts for PT60, PT8, and PT08 Part No. Old Part No. Description Price. 0700073 GT-035008 /3 HP Aspera compressor, R0a $50.00. 070005 GT-0303 Start capacitor for /3 HP Aspera R0a compressor 5.00 3. 0600675 GT-035 Relay for /3 HP Aspera R0a compressor 5.00. 070007 GT-0305 Overload protector for /3 HP Aspera R0a compressor 5.00 0700075 GT-03506 /3 HP Tecumseh compressor, R0a (after /00) 375.00 0600380 GT-0306 Start capacitor for /3 HP R0a Tecumseh compressor 0.00 0700068 GT-03 Relay for /3 HP R0a Tecumseh compressor 3.5 070008 GT-0307 Overload protector for /3 HP R0a Tecumseh compressor.00 5. 08000085 GT-03506 Condenser fan motor 35.00 6. 0800008 GT-0380 Condenser fan motor blade assembly 5.00 7. 060039 GT-035 Condenser fan motor mounting bracket 5.00 8. 08000076 GT-0360 Condenser coil (0"L x 7-5/6"W x "D) 0.00 9. 08000075 GT-03307 Fan shroud, condenser.00 0. 060008 Filter dryer with service port 5.00. 060068 GT-03800 Condensate pan (3-3/"L x 9-/"W x "D) 58.00. 070003 GT-0380 Wicking material ( required).00 3. 06006 Elbow, white nylon, /" x /".00. 060035 GT-0376 Tubing, drain, clear plastic, /" ID x 5/8" OD, per foot.5 5. 0800007 GT-0353 Base, condensing unit 30.00 6. 0600397 GT-033000 Automatic defrost timer 6hr. 3.00 7. 060033 GT-0300 Condensing unit power cord 0.00 06006 GT-0350 Cap tube 0" X.05 0.00 07000953 Accumulator, suction line 30.00 6 9 5 3 8 7 7 /3 HP, R0A (PT60, PT8 and PT08) 5 0 3 6 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com

Compressor and Condenser Related Parts for FV and FV8 Part No. Description Price. 00008 /5 HP Aspera compressor, R (before 0/00) $535.00 0600 /5 HP Tecumseh compressor, R (after 0/00 and before 0/0/0) 50.00 00008 Compressor, /hp, 0V, Tecumseh model AEA30YXA (after 0/0/0) 5.00. 0600379 Start capacitor for /5HP Aspera R compressor (before 0/00) 0.00 060038 Start Capacitor, compressor, /hp 3a & /5hp R, 0V 5.00 Tecumseh model AEA30YXA (after 0/00) 3. 0600675 Relay for /5 HP Aspera R compressor (before 0/00) 5.00 06005 Relay, compressor, /hp R3a & /5hp R (after 0/00) 9.00. 08000069 Overload protector for /5 HP Aspera R compressor (before 0/00) 5.00 0600303 Overload protector, /hp 3a & /5hp R, 0V, Compressor, model 5.00 AEA30YXA & AEA95EXA (after 0/00) 5. 070005 Fan shroud, condenser 5.00 6. 06009 Condenser fan motor, 6W 00.00 7. 0700055 Condenser fan motor blade.00 8. 06003 Condenser fan motor mounting bracket 5.00 9. 08000078 Condenser coil (3"L x 8-/"W x -/"D) 5.00 0. 060008 Filter dryer with service port 5.00. 080005 Condensate pan (7"L x 3-7/8"W x -/"D), FV 60.00. 070003 Wicking material ( required for the FV8).00 0700060 Condensate pan, FV8 65.00 3. 06006 Elbow, white nylon, /" x /".00. 060035 Tubing, drain, clear plastic, /" ID x 5/8" OD, per foot.5 5. 0600397 Automatic defrost timer 6hr. 3.00 6. 060033 Condensing unit power cord 0.00 0000 Cap tube 60" X.036" (before 0/0/0) 0.00 0600359 Cap tube.09", per foot, 0" required (after 0/0/0).00 07000953 Accumulator, suction line 30.00 5 6 5 9 0 7 8 6 3 3 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com

Evaporators and Related Parts Part No. Old Part No. Description Price. 06003 GT-0330 Expansion valve, remote model, R refrigerant $5.00 06006 GT-03309 Expansion valve, remote model, R3a refrigerant 0.00 06007 GT-033 Expansion valve, remote model, R0a refrigerant 30.00. 0600385 GT-0350 Filter dryer for remote coolers 0.00 3. 060005 GT-0330 Thermostat with knob and plate [Selco] 50.00. 060063 GT-0389 Knob only 3.00 5. 06003 GT-03935 Rope lighting, replacement kit, for BB, BB36.00 06003 GT-03936 Rope lighting, replacement kit, for BB60, ND8, ND5, LPT36 6.00 060033 GT-03937 Rope lighting, replacement kit, for BB8, ND7 8.00 06003 GT-03938 Rope lighting, replacement kit, for BB08 0.00 6. 06009 GT-03905 Light, fluorescent, plug-in 5.00 7. 000059 GT-03300 Switch (prior to 9/0) 8.00 0600 GT-033 Switch 5.00 8. 06000888 GT-03330 Electrical Outlet, black (Triboro with no ground) 7.50 060009 GT-03330 Receptacle, snap in with ground 5.00 9. 0600589 GT-0308 Solenoid valve, remote cooler 85.00 0. 0600590 GT-0309 Solenoid Coil, 0V, remote cooler 50.00. 0600553 GT-0380 Thermometer 6.00. 0600 GT-0395 Light bulb cover. clear plastic 0.00 3. 0800086 Light socket with wire lead, set of.00. 06005 GT-0396 Light bulb, GE# F6T5 3.00 06006 GT-0397 Ballast for one light evaporator housing 30.00 0600 Kit, fluorescent light conversion, replaces single ballast for dual light systems 5.00 06007 GT-0398 Ballast for two light evaporator housing 60.00 0600 GT-039 Starter base, fluorescent light 7.00 06000 GT-039 Starter, fluorescent light, -6-8 watt 5.00 000089 GT-03908 Light bulb, fluorescent, 36" long, T (prior to 08-07) 3.50 06003 GT-0397 Ballast, 0V, lamp, rapid start (use with 000089) 76.00 00036 Bulb, Fluorescent 36", 5W T8 (after 08-07).00 00033 Ballast, 3W T8 (use with 00036) 76.00 000530 Lamp holder, Fluorescent light, set of 9.50 7 3 5 6 0 8 9 3 3 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com

Evaporators and Related Parts Blower Motor Assembly Endwall BB8, BB08, ND7, ND9, KC5, KC7*, KC8 *KC7 Note: Prior to SN 0373N Mf d --03 6 0600387 Evaporator Coil for BB Self-contained, KC (8" L, -/8" H, 3-/" W) 5 5 3 Evaporator Fan Replacement Parts Endwall BB36, BB60, ND5, All Non Endwall Models, and 6 KC7 SN 0373N Mf d --03 and later 06003683 Evaporator Drain Pan, Left, for Endwall Models BB36, BB60, BB8, BB08, ND5, ND7, ND9, KC5, KC7, and KC8 (9-/8" L, 5" H, /" W) 7 0600893 Evaporator Coil for Endwall Models BB36, BB60, BB8, BB08, ND5, ND7, ND9, KC5, KC7, KC8 (6" L, 6" H, " W) 7 060007 Drain Pan for BB Self-contained, KC (8-/" L, 3-7/8" H, " W) 0600536 Drain Pan Assembly for Non Endwall Models BB8, BB60, BB7, BB8, ND5, ND7, KC8, KC7, KC8 (8-5/8" L, -5/8" H, 3/" W) 8 0600390 Evaporator Coil for BB Remote, BB36, LP8, LP60, PT8, FV, FV8 (8-3/" L, -5/8" H, " W) 9 060039 Evaporator Coil for LP7, LP8, LP96, LP08, PT7, PT8, PT96, PT08 (39-/" L, -5/8" H, " W) 8 06005363 Drain Pan for BB96, BB08 (39-/" L, -5/8" H, 3/" W) 0600060 Drain Pan for PT8 (0-3/8" L, -3/" H, " W) 9 0 0600386 Evaporator Coil for Non Endwall Models BB8, BB60, BB7, BB8, ND8, ND0, ND5, ND60 ND7, KC8, KC7, KC8 (7-/" L, " H, -7/8" W) 3 08000077 Evaporator Coil for BB96, BB08, ND80 (38-/" L, " H, -7/8" W) 06000607 Drain Pan for PT7, PT8, PT96, PT08 (-/8" L, -3/" H, " W) 0600063 Drain Pan for BB Remote, BB36, LP8, LP60 (0-3/8" L, -3/" H, " W) 0 0600063 Drain Pan for LP7, LP8, LP96, LP08 (-/8" L, -3/" H, " W) 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com

Evaporators and Related Parts Part No. Old Part No. Description Price. 060053 GT-0359 Blower motor assembly (Endwall BB8, BB08, ND7, ND9, $5.00 KC5, KC7, KC8). 0600383 GT-0330 Evaporator fan guard (Endwall BB36, BB60, ND5 & All Non Endwall Models).00 3. 0600395 GT-0380 Evaporator fan motor blade, white plastic (All Non Endwall Models) 5.00. 06005 GT-03507 Evaporator fan motor (Endwall BB36, BB60, ND5 & All Non Endwall Models) 5.00 5. 0700030 GT-035 Evaporator fan motor mounting bracket (Endwall BB36, BB60, ND5.00 & All Non Endwall Models) 06000 Evaporator fan (BB and KC 3/5/7 and after) 60.00 06005 Evaporator fan motor (BB and KC prior to 3/5/7) 5.00 6. 0600387 GT-03605 Evaporator coil (BB Self-contained, KC) 35.00 7. 0600893 Evaporator coil (Endwall Models BB36, BB60, BB8, BB08, 0.00 ND5, ND7, ND9, KC5, KC7, KC8) (after 3/06) 0600305 Evaporator coil replacement kit (BB36, BB60, BB8, 0.00 BB08, ND5, ND7, ND9 Endwall Models) (prior to 3/06) It is also necessary to purchase a drain pan, 0600368 or 06003683 8. 0600390 GT-036 Evaporator coil (BB Remote, BB36, LP8, LP60, PT8, FV, FV8) 0.00 060039 GT-0368 Evaporator coil (PT60) 30.00 9. 060039 GT-0363 Evaporator coil (LP7, LP8, LP96, LP08, PT8, PT96, PT08) 30.00 0. 0600386 GT-03603 Evaporator coil (Non Endwall Models, BB8, BB60, BB7, BB8, 70.00 ND0, ND8, ND5, ND60 ND7, KC8, KC7, KC8). 08000077 GT-0360 Evaporator coil (BB96, BB08, ND80) 85.00. 06000 TXV valve extension Cover (3 door remote coolers).00 3. 0600 TXV valve extension Cover ( door remote coolers).00. 060005 TXV valve Cover (all remote coolers).00 5 060007 GT-03800 Evaporator drain pan (BB Self-contained, KC) 8.00 0600068 Evaporator drain pan (KC) (prior to 0//06) 5.00 6. 0600368 Evaporator drain pan, Right (Endwall Models BB36, BB60, BB8, 60.00 BB08, ND5, ND7, ND9, KC5, KC7, KC8) (after 3/06) 06003683 Evaporator drain pan, Left (Endwall Models BB36, BB60, BB8, 60.00 BB08, ND5, ND7, ND9, KC5, KC7, KC8) (after 3/06) 060008 GT-03807 Evaporator drain pan (Endwall Models BB36, BB60, BB8, 60.00 BB08, ND5, ND7, ND9) (prior to 3/06) 7. 0600536 Drain pan assembly, evaporator, fan, remote (Non Endwall Models, 5.00 BB8, BB60, BB7, BB8, ND5, ND7, KC8, KC7, KC8) 8. 06005363 Evaporator drain pan (BB96, BB08) 60.00 060085 Evaporator drain pan (PT60) 5.00 9. 0600060 Evaporator drain pan (PT8) 5.00 0. 06000607 GT-03808 Evaporator drain pan (PT7, PT8, PT96, PT08) 60.00. 0600063 GT-03809 Evaporator drain pan (BB Remote, BB36, LP8, LP60) 5.00. 0600063 GT-03800 Evaporator drain pan (LP7, LP8, LP96, LP08) 60.00 06000663 Evaporator drain pan (FV, FV8) 5.00 06008 Assembly, shroud, evaporator, -fan, - door e/w, 0 Volt 80.00 060088 Assembly, shroud, evaporator, -fan, - door e/w, 0 Volt, digital t-stat 50.00 0600609 Power supply for LED light strip 60.00 0600608 LED light strip - lights 5.00 5 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com

Doors and Related Parts Part No. Old Part No. Description Price. 06006 GT-0350 Door handle, stainless $60.00 0600653 GT-0350 Door handle, brass 0.00 0600899 Door handle, tab style, glass door, right (Prior to 003) 65.00 0600370 Door handle, tab style, glass door, left (Prior to 003) 65.00. 0600536 GT-03660 Door lock, stainless 36.00 0600009 Key, #806, for stainless cooler door lock (0600536).00 0600535 GT-03660 Door lock, brass 3.00 060000 Key, #606, for brass cooler door lock (0600535).00 0600677 GT-03506 Plug for door handle, stainless.00 0600678 GT-03508 Plug for door handle, brass.00 0000000 GT-038733 Screws for top of handle, stainless (set of ), 0/3 x " PFH Machine Screw.00 0000006 GT-038779 Screws for top of handle, brass (set of ), 0/3 x 5/8" PFH Machine Screw.00 0000006 GT-038759 Screw for bottom of handle, stainless, and screws for old style brackets.50 0000003 GT-03878 Screw for bottom of handle, black.50 3. 000076 GT-03 Hinge set, 0º swing, set of two w/screws and washers 5.00. 060050 GT-030 Hinge set, 80º swing, set of two (prior to /99 - w/ screws and washers) 5.00 5. 060066 GT-035 Hinge bracket, bottom, left (prior to /99 - w/ screws) 5.00 060067 GT-036 Hinge bracket, bottom, right (prior to /99 - w/ screws) 5.00 6. 060037 GT-030 Hinge set and brackets, 80º swing, left (complete with screws) 35.00 7. 0600373 GT-03 Hinge set and brackets, 80º swing, right (complete with screws) 35.00 8. 06003 GT-0353 Lock bracket 0.00 0600376 GT-0330 Hinge set & brackets for wood doors, 80º swing, left (complete with screws) 5.00 0600377 GT-033 Hinge set & brackets for wood doors, 80º swing, right (complete with screws) 5.00 0600378 GT-0335 Lock bracket for wood doors 0.00 9. 060030 GT-03307 Cooler door gasket, push-in style, black, 3-/" x 3-/" OD.00 0600305 GT-03308 Cooler door gasket, screw-on style (wooden doors before 6/9/90) 3½" x 3½" OD.00 0600307 GT-0337 Cooler door gasket, LP and FV models, black, 3½" x 6½" OD.00 0600309 GT-0333 Cooler door gasket, narrow door, black, 9½" x 3½" OD.00 0. 00000067 GT-03883 Screw for door hinges ( required).50. 000000 GT-03876 Bolts for brackets (6 required).50. 060000 Hinge rail, bottom, front vent coolers ( - 060085 washers required, not 0.00 included) 060085 GT-0360 Plastic washer for hinge.00 0600569 GT-03895 Bushing for hinge (gray).00 06008 Standard laminated door trim rail kit 35.00 060086 Laminated door trim rail kit, for narrow doors 35.00 060087 Laminated door trim rail kit, for low profile narrow doors 35.00 060085 Laminated door trim rail kit, for low profile doors 35.00 6 7 3 8 0 8 9 5 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com 6

Doors and Related Parts Replacement Doors for Units Manufactured PRIOR to January 999 Replacement Doors for BB, PT, RF, DS, KC7, and KC8 Models Part No. Old Part No. Description Price 060089 GT-03608 Black vinyl clad door (prior to /99) $308.00 060087 GT-03605 Unlaminated door (prior to /99) 308.00 060088 GT-03607 Laminated door (prior to /99) 8.00 060090 GT-03609 Stainless door (prior to /99) 358.00 06007 Glass door, black (prior to /99) 598.00 06007 Glass door, stainless (prior to /99) 68.00 Replacement Doors for LP and FV Models 0600505 GT-03667 Black vinyl clad door, low profile (prior to /99) 308.00 0600506 GT-03668 Unlaminated door, low profile (prior to /99) 308.00 0600507 GT-03669 Laminated door, low profile (prior to /99) 8.00 0600508 GT-03670 Stainless door, low profile (prior to /99) 358.00 060076 Glass door, low profile, black (prior to /99) 598.00 060075 Glass door, low profile, stainless (prior to /99) 68.00 Replacement Doors for ND Models 06005 GT-03673 Black vinyl clad door, narrow (prior to /99) 308.00 06005 GT-0367 Unlaminated door, narrow (prior to /99) 308.00 060053 GT-03675 Laminated door, narrow (prior to /99) 8.00 06005 GT-03676 Stainless door, narrow (prior to /99) 358.00 06007 Glass door, narrow, black (prior to /99) 598.00 060073 Glass door, narrow, stainless (prior to /99) 68.00 NOTE: Door gaskets, handles and hinges are sold separately, see page 6 for part numbers 7 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com

Doors and Related Parts Replacement Doors for Units Manufactured January 999 and After Replacement Doors for BB, PT, RF, DS, and KC Models Part No. Old Part No. Description Price 060057 GT-03680 Black vinyl clad door $308.00 060058 GT-0368 Unlaminated door 308.00 060059 GT-0368 Laminated door 8.00. 060050 GT-03683 Stainless door 358.00 0600597 Glass door, black 598.00 0600596 Glass door, stainless 68.00 0600855 Door, laminated, left hinge, BB/KC (March 5, 07 and after) 8.00 0600856 Door, laminated, right hinge, BB/KC (March 5, 07 and after) 8.00 0600857 Door, unlaminated, left hinge, BB/KC (March 5, 07 and after) 308.00 0600858 Door, unlaminated, right hinge, BB/KC (March 5, 07 and after) 308.00 Replacement Doors for LP and FV Models. 060053 GT-03686 Black vinyl clad door, low profile 308.00 06005 GT-03687 Unlaminated door, low profile 308.00 060055 GT-03688 Laminated door, low profile 8.00 060056 GT-03689 Stainless door, low profile 358.00 0600600 Glass door, low profile, black 598.00 3. 0600599 Glass door, low profile, stainless 68.00 Replacement Doors for ND Models 060059 GT-0369 Black vinyl clad door, narrow 308.00 0600530 GT-03693 Unlaminated door, narrow 308.00. 060053 GT-0369 Laminated door, narrow 8.00 060053 GT-03695 Stainless door, narrow 358.00 0600603 Glass door, narrow, black 598.00 060060 Glass door, narrow, stainless 68.00 NOTE: Door gaskets, handles and hinges are sold separately, see page 6 for part numbers 3 /6 3 /6 3 5 /8 9 /6 3 /6 7 /6 7 ½ 3 /6 3 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com 8

Doors and Related Parts Replacement Glass Doors for Units Manufactured September 003 and After NOTICE: In September of 003, we released new style glass doors for our vertical door coolers. These new style doors fit all of our units manufactured AFTER January 999, However these new style glass doors look different than the glass doors manufactured BETWEEN January 999 and September 003. Please consider this fact if you need to match the look of your replacement glass door with that of existing glass doors. If you need to order the style of glass doors manufactured between January 999 and September 003, please refer to page 5. Replacement Doors for BB, PT, RF, DS, and KC Models Part No. Old Part No. Description Price 0600596 GT-0000 Stainless Steel Glass Door $68.00 0600597 GT-000 Black Vinyl Clad Glass Door 598.00 5. 0600598 GT-000 Laminated Glass Door 78.00 0600859 Door, black, BB/KC (March 5, 07 and after) 598.00 06008550 Door, stainless steel, BB/KC (March 5, 07 and after) 68.00 0600855 Door, laminated glass, left hinge, BB/KC (March 5, 07 and after) 78.00 0600855 Door, laminated glass, right hinge, BB/KC (March 5, 07 and after) 78.00 Replacement Doors for LP and FV Models Part No. Old Part No. Description Price 6. 0600599 GT-000 Stainless Steel Glass Door 68.00 0600600 GT-00 Black Vinyl Clad Glass Door 598.00 060060 GT-00 Laminated Glass Door 78.00 Replacement Doors for ND Models Part No. Old Part No. Description Price 060060 GT-000 Stainless Steel Glass Door 68.00 7. 0600603 GT-00 Black Vinyl Clad Glass Door 598.00 060060 GT-00 Laminated Glass Door 78.00 NOTE: Door gaskets, handles, and hinges are sold separately, see page 6 for part numbers 3 5/8" 9 5/8" 3 5/8" 33 3/8" 7 /" 33 3/8" 5 6 7 9 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com

Shelving, Racks and Related Parts Part No. Old Part No. Description Price. 0600399 GT-0330 8⅞" x 0⅛" grey coated shelf (fits BB, BB36, FV, $77.00 ND7 middle door and refrig. end of remote PT models). 060000 GT-0330 8⅞" x -/6" grey coated shelf with corner notch (fits end 77.00 doors on BB, and LP models and both doors on FV8) 06000 GT-03303 8⅞" x 3⅞" grey coated shelf (fits middle doors on BB, LP, 77.00 PT and RF models) 06000 GT-0335 8⅞" x 8-/6" grey coated shelf (fits end doors on ND models) 77.00 060003 GT-0337 8⅞" x -/6" grey coated shelf (fits end doors on PT and RF models) 77.00 0600397 8⅞" x -/6" grey coated shelf (fits NDPT8 and 7 coolers) 77.00 06000 Shelf divider 5.00 060078 Floor, stainless, fits BGS-8 0.00 060079 Floor, stainless, fits BGS- 37.00 060080 Floor, stainless, fits BGS-30 69.00 06008 Shelf, stainless, fits BGS-8 0.00 06008 Shelf, stainless, fits BGS- 37.00 060083 Shelf, stainless, fits BGS-30 69.00 06008 Shelf angle for BGS 0.00 00008 GT-0336 3½" X 3¼" coated shelf (fits CM models) 06.00 0700059 9⅝" X 9⅝" shelf (fits MFV bottom and middle) 50.00 0700060 9-3/6" X 9⅝" shelf (fits MFV top) 35.00 3. 0600065 8⅞" X 0⅛" dry storage shelf (fits DS manufactured before 0/03) 63.00 (fits BB, BB36, FV, ND7 middle door and refrig. end of remote PT models) 060095 GT-03335 0⅝" X ½" dry storage shelf (fits DS manufactured after 0/03) 63.00. 060096 GT-037707 Floor for DS (manufactured after 0/03) 63.00 0600067 GT-0339 8⅞" X 5⅞" dry storage shelf (fits DS36) 63.00 0600068 8⅞" X 8-/6" dry storage shelf (fits end doors on ND models) 63.00 0600069 GT-03330 8⅞" X -/6" dry storage shelf (fits DS8 and DS7 ends) 63.00 0600070 GT-0333 8⅞" X 3⅞" dry storage shelf (fits DS7, middle) 63.00 0600557 GT-0383 Pilaster 5.00 060057 GT-038833 Thumbscrew, stainless steel, for pilaster.00 0600565 GT-03868 Clip, for pilaster, stainless steel.00 0000008 Nut, acorn, 8/3" natural nylon.00 0600579 GT-00305 ABS Scuff Channel with mounting screws 6.00 0600580 GT-0038 ABS Scuff Channel (ND models) with mounting screws 6.00 5. W-RACK-8 Wine racks, set of two for 8-/6" shelf (shelf not included) 88.00 W-RACK-0 Wine racks, set of two for 0⅛" shelf (shelf not included) 88.00 W-RACK- Wine racks, set of two for -/6" shelf (shelf not included) 88.00 060060 K-RACK-ND Keg rack, stainless, 8¾" (ND end) 95.00 060000 K-RACK-KC Keg rack, stainless, 0¾" (KC models manufactured before 0//06) 95.00 0600608 K-RACK- Keg rack, stainless, 0¾" (BB self contained & KC, BB end & ND middle) 95.00 6. 0600609 K-RACK- Keg rack, stainless, ½" (BB middle doors) 95.00 06003035 K-RACK-PT Keg rack, stainless, ½" (PT end) 95.00 0600003 Keg rack, stainless, ½" (PT middle) 95.00 3 Dry Storage Shelf 8-7/8" x 0-/8" 8-7/8" x -/6" 6 DS Dry Storage Floor 5 Wine Rack (shelf not included) Keg Rack 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com 30

Refrigeration Compartment Covers Refrigeration Compartment Covers for BB and KC Models After //06 Part No. Old Part No. Description Price 06008 Panel, access, BB/KC $.00 Refrigeration Compartment Covers for Endwall BB, ND, KC5, KC7 & KC8 Models. 060006 GT-03680 Grill, black vinyl clad, endwall BB, ND, or KC, 33-/ H, -3/ L, -3/8 W 0.00 06003050 GT-0368 Grill, stainless, endwall BB, ND, or KC, 33-/ H, -3/ L, -3/8 W 0.00 0600066 Grill, unlaminated, endwall BB, ND, or KC, 33-/ H, -3/ L, -3/8 W 0.00 Refrigeration Compartment Covers for PT, and Non Endwall BB, ND5, ND7, KC7, and KC8 Models. 0600763 Grill, black vinyl clad, PT and non-endwall BB, ND, or KC, 33-/ H, -3/ L, -3/8 W 0.00 0600763 Grill, stainless, PT and non-endwall BB, ND, or KC, 33-/ H, -3/ L, -3/8 W 0.00 0600736 Grill, unlaminated, PT and non-endwall BB, ND, or KC, 33-/ H, -3/ L, -3/8 W 0.00 3. 0600066 GT-0368 Grill, black vinyl clad, low refrigeration, PT and non-endwall BB, ND, or KC, 0.00 9-/ H, -3/ L, -3/8 W 0600737 GT-03683 Grill, stainless, low refrigeration, PT and non-endwall BB, ND, or KC, 9-/ H, 30.00-3/ L, -3/8 W Refrigeration Compartment Covers for LP Models 0600738 GT-03686 Grill, black vinyl clad, LP models, 7-/ H, -3/ L, -3/8 W 0.00. 0600739 GT-03687 Grill, stainless, LP models, 7-/ H, -3/ L, -3/8 W 0.00 0600763 Grill, unlaminated, LP models, 7-/ H, -3/ L, -3/8 W 0.00 Refrigeration Compartment Covers for ND8 and KC8 Models 5. 060070 GT-03690 Grill, black vinyl clad, 8 refrigeration, 33-/ H, 7-3/ L, -3/8 W 80.00 06007 GT-0369 Grill, stainless, 8 refrigeration, 33-/ H, 7-3/ L, -3/8 W 00.00 Refrigeration Compartment Covers for FV and FV8 Models 6. 070000 GT-0369 Grill, front, black vinyl clad, ST or FV, 9-3/8 H, 0-7/8 L, 3/8 W 50.00 0700003 GT-03630 Grill, front, stainless, ST or FV, 9-3/8 H, 0-7/8 L, 3/8 W 80.00 06007 Grill, front, black vinyl clad, FV8, 9-3/8 H, -7/8 L, 3/8 W 70.00 060073 Grill, front, stainless, FV8, 9-3/8 H, -7/8 L, 3/8 W 90.00 Refrigeration Compartment Covers for 8 Wide Compressor Compartments 06007 GT-03695 Grill, black vinyl clad, 8 refrigeration, 33-/ H, 7-3/ L, -3/8 W 90.00 060075 GT-03696 Grill, stainless, 8 refrigeration, 33-/ H, 7-3/ L, -3/8 W 50.00 7. 060076 GT-03697 Grill, black vinyl clad, 8 low refrigeration, 9-/ H, 7-3/ L, -3/8 W 80.00 0600735 GT-03698 Grill, stainless, 8 low refrigeration, 9-/ H, 7-3/ L, -3/8 W 0.00 Refrigeration Compartment Covers Related Parts 8. 0600360 GT-03005 Grill insert, refrigeration compartment cover, polypropylene, black 5.00 9. 060036 GT-03006 Grill insert, refrigeration compartment cover, polypropylene, gray 5.00 060056 GT-03703 Filter, refrigeration compartment grill insert 7.00 0. 060088 Laminated compressor compartment trim rail kit, for BB, PT, and ND models 39.00 060089 Laminated compressor compartment trim rail kit, for LP models 39.00 0600850 Laminated compressor compartment trim rail kit, for special low profile compartments 39.00 0600555 Rubber Bumper.5 8 3 9 5 7 0 6 3 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com

0 Volt Electrical Parts BB Self contained & KC Compressor, Condenser & Related Parts Part No. Description Price 060037 Compressor, /6HP, 0V, 50Hz, R3a $35.00 06003 Relay, compressor, /6HP, 0V/50Hz, R3a 5.00 0600 Overload protector, compressor, /6HP, 0V/50Hz, R3a 5.00 0600398 Automatic defrost timer, 6 hour, 0V, 50Hz 3.00 06008 Condenser fan motor, 0V 57.00 Standard BB36 Compressor, Condenser & Related Parts 000083 Compressor, /5 HP, 0V, 50Hz, R $500.00 00096 Start capacitor, /5 HP, R, 0V/50Hz Tecumseh compressor 5.00 00098 Relay, /5 HP, R, 0V/50Hz Tecumseh compressor 9.50 00099 Overload protector, /5 HP, R, 0V/50Hz Tecumseh 5.00 09000337 Condenser fan motor, 0V, 6 watt 0.00 0600398 Automatic defrost timer, 6 hour, 0V, 50 Hz 3.00 LP60, LP8, LP08, Non Endwall BB60, BB8, BB08, ND5, ND7, ND9, KC8, KC7, KC8 060036 Compressor, /3 HP, 0V, 50Hz, R $500.00 0600793 Start capacitor, for /3 HP R0A and R compressor, 0/50Hz 5.00 06006 Relay, compressor, /3HP, 0V/50Hz, R 5.00 06007 Overload protector, compressor, /3HP, 0V/50Hz, R 5.00 09000337 Condenser fan motor, 0V, 6 watt 0.00 0600398 Automatic defrost timer, 6 hour, 0V, 50 Hz 3.00 BB36, BB60, ND5, & KC5 Compressor & Condenser Related Parts For Endwall Models 06000 Compressor, /3 HP, 0V, 50Hz, R3a $55.00 060003 Relay, /3 HP 0V 50Hz R3a Tecumseh compressor.00 0600057 Overload protector, /3 HP 0V 50Hz R3a Tecumseh compressor 7.00 00096 Start capacitor, /3 HP 0V 50Hz R3a Tecumseh compressor 5.00 06005 Condenser fan motor, 9 watt, 0V 50Hz 0.00 0600398 Automatic defrost timer, 6 hour, 0V, 50 Hz 3.00 BB8, BB08, ND7, ND9, KC7 & KC8 Compressor & Condenser Related Parts For Endwall Models 060038 Compressor, /3 HP, 0V, 50Hz, R0a $50.00 0600793 Start capacitor, for /3 HP R0A and R compressor, 0/50Hz 5.00 060079 Relay, /3 HP 0V 50Hz R0a compressor 5.00 0600795 Overload protector, /3 HP 0V 50Hz R0a compressor 5.00 09000337 Condenser fan motor, 0V, 6 watt 0.00 0600398 Automatic defrost timer, 6 hour, 0V, 50 Hz 3.00 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com 3

0 Volt Electrical Parts PT60, PT8 & PT08 Compressor & Condenser Related Parts 060038 Compressor, /3 HP, 0V, 50Hz, R0a $50.00 0600793 Start capacitor, for /3 HP R0A and R compressor, 0/50Hz 5.00 060079 Relay, /3 HP 0V 50Hz R0a compressor 5.00 0600795 Overload protector, /3 HP 0V 50Hz R0a compressor 5.00 09000337 Condenser fan motor, 0V, 6 watt 0.00 0600398 Automatic defrost timer, 6 hour, 0V, 50 Hz 3.00 FV & FV8 Compressor & Condenser Related Parts Prior to 00 000083 Compressor, /5 HP, 0V, 50Hz, R $500.00 00096 Start capacitor, /5 HP 0V/50Hz R Tecumseh compressor 5.00 00098 Relay, /5 HP 0V/50Hz R Tecumseh compressor 9.50 00099 Overload protector, /5 HP 0V/50Hz R Tecumseh compressor 5.00 06005 Condenser fan motor, 9 watt, 0V 50Hz 5.00 0600398 Automatic defrost timer, 6 hour, 0V, 50 Hz 3.00 FV & FV8 Compressor & Condenser Related Parts After 0/0/00 06000 Compressor, /3 HP, 0V, 50Hz, R3a $55.00 060003 Relay, /3 HP 0V 50Hz R3a Tecumseh compressor.00 0600057 Overload protector, /3 HP 0V 50Hz R3a Tecumseh compressor 7.00 00096 Start capacitor, /3 HP 0V 50Hz R3a Tecumseh compressor 5.00 06005 Condenser fan motor, 9 watt, 0V 50Hz 0.00 0600398 Automatic defrost timer, 6 hour, 0V, 50 Hz 3.00 Vertical Door Cooler Evaporators & Related Parts 060030 Rope lighting, 0V, 50Hz, per foot 9.00 060038 Rope lighting power cord and connector, 0V European plug style 0.00 060055 Blower motor, 0V (Endwall BB8, BB08, ND7, ND9, KC5, KC7, KC8) 70.00 06008 Evaporator fan motor, 0V (Endwall BB36, BB60, ND5, & All Non EW Models) 57.00 06000 Assembly, shroud, evaporator, -fan, - door e/w, 0 Volt 5.00 06000 Assembly, shroud, evaporator, -fan, - door e/w, 0 Volt, digital t-stat 600.00 Electrical Components Part No. Description Price 06006 Replacement powercord assembly, includes (060057 0600957) $0.00 33 800.78.03 989.75.75 Fax 800.838.0888 / 989.75. www.glastender.com

UNPARALLELED UNDERBAR DESIGN & ENGINEERING Expect more more flexibility more features Glastender has the most complete line of bar equipment and the ability to manufacture custom units, giving you virtually unlimited design flexibility. Each piece of equipment is engineered with features that enhance your efficiency, ease your maintenance, and prolong the life of your investment. The flexibility you want. The features you need. Glastender. Expect more. GLASSWASHERS COCKTAIL STATIONS COOLERS FROSTERS BEER SYSTEMS