Distributed Generation (greater than 10kW) Connecting to Vector s electricity network

Similar documents
Microgrid Fault Protection Based on Symmetrical and Differential Current Components

FACILITY CONNECTION STANDARD

TRANSMISSION ENGINEERING STANDARDS SUBSTATIONS

TRANSMISSION ENGINEERING STANDARDS SUBSTATIONS

CONNECTION, ENERGISING, COMMISSIONING AND PERMANENT DISCONNECTION OF HIGH VOLTAGE APPARATUS

TOP R4 Unknown Operating State

2005 EAF Melt Shops in North America MARKET STUDY Final Report

Business Process and Procedures Workstream. Event Log Collection, Processing & Delivery process (BP05)

National Grid / DG Installation Process Guide per NY SIR / July 2011 ver. 1.0

National Grid / Supplement to Specifications for Electrical Installations / ESB ver Doc. File: ESB _ver3_

Rules for Application of DUoS Tariff Group

AGC 200 Advanced Gen-set Controller OPERATOR S MANUAL

High Speed Rail (London- West Midlands)

Policy and Specification for the Interface with Independent Distribution Network Operators Installations

Consumer unit replacement in domestic and similar premises

PRODUCED BY THE OPERATIONS DIRECTORATE OF ENERGY NETWORKS ASSOCIATION

Electrical Protection and Transportation Installations for Non-domestic Buildings

Application of ALPHA Inverter in the Transformation Plan of Central Air-Conditioning

clipboarddesigns INTERIOR DESIGN HOME STYLING ONLINE

Documentation guide to get your plant on the positive list (Category A1/A2)

Loss Prevention Standard

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Loss Prevention Standard

OHIO UNIVERSITY RADIATION SAFETY REVIEW

PowerRouter application guideline

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

CHC's One Big Housing Conference Health and Safety Update: Gas Safety

National Grid Requirements for Interconnection of Parallel Generation

ELEVATOR RESCUE PROCEDURE

Project Briefing Document. Section 3 Electrical Services design guide and specifications

PAC1500Xi PORTABLE APPLIANCE CHECKER

AS/NZS 3190:2011 AS/NZS

INTRUDER ALARM FOR BUSINESS SECURITY

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

I. Scope: II. Environmental Health and Safety Fire Alarm System Impairment Program - Guideline Revision Date: April, 2018

AS/NZS :2014. Electrical equipment for coal mines Introduction, inspection and maintenance AS/NZS :2014. Part 1: For hazardous areas

NZQA registered unit standard version 4 Page 1 of 5

Australian/New Zealand Standard

HAZARDOUS MATERIALS/WASTE EMERGENCY CONTINGENCY PLAN University of Southern Maine Portland Campus

C-NRPP Quality Assurance Guidance for Radon Test Devices

NZS 7901:2014. Electricity and gas industries Safety management systems for public safety NZS 7901:2014. New Zealand Standard

Report reference No...: 10TH0052_AS4777_+_ISR_3 Tested by (printed name and signature)...: Urs Seifert. Approved by (printed name and signature)...

Guide Specification Model CTG Automatic Transfer Switch

SCHEDULE ONE TO CUSTOMER CONTRACT DOCUMENT STANDARD INSTALLATION CONDITIONS FUEL CONVERSION PRODUCT COMBINATIONS BREAKDOWN HOT WATER REPLACEMENT

Australian/New Zealand Standard

Australian Standard. Emergency escape lighting and exit signs for buildings. Part 1: System design, installation and operation AS 2293.

June 2017 (Updated 18 January 2018) Fire Safety Policy. Peter Webb, Project Manager Compliance First Choice Homes Oldham Limited

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks

-SQA- SCOTTISH QUALIFICATIONS AUTHORITY. Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR

HAZARDOUS MATERIALS/WASTE EMERGENCY CONTINGENCY PLAN University of Southern Maine Portland Campus

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

This EREC G98 draft uses text from a number of sources and is therefore colour coded to demonstrate where the words have come from as follows.

Smart Metering Infrastructure (SMI)

GEM-C Wireless User & Installation Manual. Revision October Apollo Solar Electric Limited. Documentation

OPERATING INSTRUCTIONS

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Standard PRC Transmission Relay Loadability

HIGH VOLTAGE ELECTRICAL SUPPLY CONNECTIONS Overview of High Voltage Customer Obligations

Fire Safety Policy & Fire Safety Management System Version October 2013 Emergency Evacuation Procedures

EUROPUMP ATEX Guideline Part II

STATEMENT OF WORK ELECTRICAL REPAIR / MAINTENANCE BUILDING PROJECT FDC RACCOON CREEK STATE PARK (BEAVER COUNTY)

MANNED GUARDING. CALL US today for a FREE Quotation on +971 (4) Dubai, UAE

AUCKLAND DESIGN OFFICE. Terms of Reference: Auckland Urban Design Panel

OPERATING INSTRUCTIONS

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

AS/NZS 3133:2008 AS/NZS

AS/NZS :2014

Electrical Safety Program

Policies and Procedures for the Missouri Master Gardener Program

Australian/New Zealand Standard

QUICKSMART Universal Exit Light EXITSM. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

DELOMATIC 400, DM-400 HYDRO

Safety Best Practices Manual

CONTENTS AUTOMATIC TRANSFER SWITCHES

PART 3-O REQUIREMENTS FOR SPRINKLER SYSTEMS MAINTENANCE AND SUPERVISION. 3-O Introduction O.1 Scope of Maintenance and Supervision...

Farlingaye High School. Lone Working Policy

INTRUDER ALARM FOR BUSINESS SECURITY

SCHEDULE 2 - EXHIBIT 1 DATED [ ] NATIONAL GRID ELECTRICITY TRANSMISSION PLC (1) and THE CONNECTION AND USE OF SYSTEM CODE

Installation and Maintenance Manual for Dimako NERM Panels REV 4. NERM Reference Manual NERM Panels 1 of 7

User instructions and quick-fit guide

A REPORT TO THE BOARD OF COMMISSIONERS OF PUBLIC UTILITIES. Electrical. Mechanical. Civil. i Protection & Control. b^n Telecontrol.

Symmetra MW Modbus Data Points

Dehumidifier User Manual. (For the series of DP40~DP70)

CIRCUIT BREAKER FAIL PROTECTION

Substation Signage. Document Number: 1-11-FR-12

Alan Wells Technical and Standards Director Certsure LLP trading as NICEIC

Guide to Membership Assessments

Technical documentation DTR

Requirements for Electrical Installations

NOTTINGHAM CITY HOMES

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

Electrical Safety Policy

SECTION GENERATOR PARALLELING CONTROLS

ELECTRIC FIRE PUMP CONTROLLER

CYNGOR SIR POWYS COUNTY COUNCIL

Majis Industrial Services SAOC TENDER NO. MISCP/09/2014

Replacing a consumer unit in domestic premises where lighting circuits have no protective conductor

B. Section Transfer Switches: Automatic transfer switch.

Consumer Products Services Germany GmbH Türkheim Germany

Near Howe Accident Risk Assessment

Transcription:

Distributed Generation (greater than 10kW) Connecting to Vector s electricity network Important information about installing distributed generation with capacity greater than 10 kilowatts

Purpose of this document: This document provides a brief outline of the process for installing distributed generation with capacity of greater than 10 kilowatts on Vector s electricity network. Its purpose is to provide the prospective generator with the key aspects involved when connecting distributed generation to Vector s electricity networks, and is not intended to be a comprehensive handbook. This document is to be read in conjunction with the following Vector documents: Technical Requirements for Connection of Distributed Generation Vector s Distribution Code Initial Application Form for Connection of Distributed Generation (>10kW). These documents are available at Vector s website: www.vector.co.nz/greater-than-10kw Each application for distributed generation is different and needs to be discussed with a Vector representative. For further information about distributed generation, please email; dginfo.applications@vector.co.nz. Distributed Generation (>10kW) Vector Limited Page 2 of 14

Contents DISTRIBUTED GENERATION SETTING THE SCENE... 4 FOR FURTHER INFORMATION... 4 IMPLICATIONS OF CONNECTING DISTRIBUTED GENERATION... 4 Health and safety implications... 4 Technical implications... 5 Commercial implications... 5 Other implications and considerations... 6 Typical generator connection diagram... 7 TECHNICAL STANDARDS TO BE MET... 7 IMPORTANT STEPS TO CONNECTING DISTRIBUTED GENERATION... 9 Read Vector s distributed generation documents... 9 Initial Application to Vector... 9 Vector to discuss with you... 9 Design in conjunction... 10 Installation of distributed generation... 10 Final application and approval to proceed... 10 Connection to Vector s electricity network... 10 FEES... 11 USEFUL LINKS... ERROR! BOOKMARK NOT DEFINED. INFORMATION REQUIREMENTS FOR DISTRIBUTED GENERATION... 12 Distributed Generation (>10kW) Vector Limited Page 3 of 14

Distributed generation setting the scene Installation of distributed generation can be a complex matter and for connections greater than 10kW you need to involve Vector from the early stages in your investigation process. The sooner you involve Vector, the more informed you can be and the smoother the process can run. Connection of distributed generation to an electricity network has a wide range of implications. This includes personnel and public safety, network performance, service quality, investment in the network, and commercial agreements. If your generation is to be connected to Vector s network then it must comply with Vector s requirements for connection of distributed generation to our network. The electricity you may sell from your distributed generation system is distributed on the network of your lines company. Vector is the lines company for Auckland (from Wellsford to Papakura). For further information When you decide to install distributed generation, you want to do it right. We want you to do it right too. If you have any queries or need more information after reading this document, please contact us: Email: Website: dginfo.applications@vector.co.nz www.vector.co.nz/electricity/distributed-generation Implications of connecting distributed generation Historically, distribution networks have been designed for the distribution of electricity from the national grid to consumers, and have not been designed to allow injection of electricity mid-network. As a result the health and safety, technical, and commercial implications outlined below can occur. Health and safety implications The connection of distributed generation requires safety equipment and procedures to be put in place to ensure safe interaction between your private network and Vector s electricity network. If not managed correctly, it is possible for your generation system to backfeed electricity onto our network which could endanger the lives of Vector personnel and the public. Distributed Generation (>10kW) Vector Limited Page 4 of 14

For everyone s safety your generating system must also meet statutory requirements, comply with international manufacturing standards and safety standards specified by Vector. Vector maintains the right to disconnect any site found to be unsafe, and shall not reconnect the site until it is approved safe. Please respect these standards and remember this first rule for safety: Check with Vector first! For everyone s safety, you must check with Vector before installing or connecting your distributed generation system. Technical implications The effect of connecting a distributed generator to our network requires detailed investigation and discussion with Vector. Depending on the particular situation, the connection of your generation may require the reinforcement of the existing network. Technical aspects to be discussed include: Safety requirements Connection capacity requirements Protection and control requirements Synchronisation between networks Fault current Islanding Black start capability (mainly for larger generation stations) Power quality Reactive power compensation Other aspects relevant to individual situations. Commercial implications Connection costs Connecting your distributed generation system to Vector s network will require us to install additional connection assets. Dependent on your specific connection, there may also be other network reinforcement and/or investment costs. Vector will pass these associated costs on to you. Ongoing costs Vector may charge for ongoing expenses incurred because of your distributed generation connection to our network. Where we incur ongoing or periodic expenses, such as Distributed Generation (>10kW) Vector Limited Page 5 of 14

expenses for routine maintenance, we may apply a connection charge to help cover these costs. The charges and associated commercial terms need to be individualised for each generator and will be formalised in a Distributed Generation Connection Agreement. A draft version of this agreement is available to download from Vector s website. Other implications and considerations Timing of installation The connection of distributed generation to our network can be complex and may require detailed design and planning. Approval for this must be obtained Vector prior to connection so you will need to factor this into your timeframe. Metering Your electricity retailer may need to install a new meter. This new meter will be able to measure the amount of surplus electricity that you generate and sell back. An import/export meter is the minimum requirement for use with distributed generation systems. An import/export meter has the capability to measure both imported and exported volumes of energy. This ensures you receive the correct payment for the electricity you contribute to the electricity retailer and that you are charged correctly when you use electricity supplied by the retailer. There may be extra rental costs for this type of meter and your electricity retailer will advise you about these. You may also have to pay your electricity retailer a tariff or meter change fee, depending on your location and your current metering configuration. Vector s network information systems Vector keeps comprehensive information systems for its networks. These will need to be updated to include your generator system details. Distributed Generation (>10kW) Vector Limited Page 6 of 14

Typical distributed generation connection diagram The following is a generic representation of a typical distributed generation connection. Each installation is different and needs to be discussed with Vector. Vector s electricity network Circuit Breaker Point of Common Coupling (PCC) Generator Interface, including but not limited to: isolating switch input/output meter(s) synchronisation protection and control equipment Distributed Generator s private electricity network Distributed Generation Source ~ Customer s Main Switchboard Internal Wiring Technical standards The following is a summary of Vector s standards that must be met, and are available to download as documents from Vector s website: Vector s Distribution Code Technical Requirements for the Connection of Distributed Generation (DG) Technical requirements for connection of small capacity distributed generation via inverters to Vector s network. Distributed Generation (>10kW) Vector Limited Page 7 of 14

The following is a summary of the key industry standards that must be met: IEC Standards IEC 60255 Electrical Relays IEC 60068-2 Environmental Testing IEC 61000-3 Electromagnetic Compatibility (Limits) IEC 61000-4 Electromagnetic Compatibility (Testing and Measuring Techniques). Electrical Codes of Practice Available at the Energy Safety Service (ESS) website www.ess.govt.nz/rules/rules_codes.asp. AS/NZS Standards, in particular: AS/NZS 3000 Electrical Installations (known as the Australian/New Zealand Wiring Rules) AS 4777 provides standards for connecting inverter-based systems, but is only a useful guideline to installing other forms of generation These standards are available at www.standards.com.au. Other standards may be applicable depending on your generation system, and these need to be discussed with Vector. Distributed Generation (>10kW) Vector Limited Page 8 of 14

Important steps to connecting distributed generation Read Vector s distributed generation documents Please familiarise yourself with the documents available on Vector s website. If you do not have access to the website, contact Vector to request a copy of these documents: Technical Requirements for Connection of Distributed Generation Vector s Distribution Code Initial Application Form for Connection of Distributed Generation (>10kW). In addition to the above, we recommend you review the Regulated Terms of connection, as outlined under Schedule 6.2, Part 6 of the Electricity Industry Participation Code 2010 (the Code). You can find the Regulated Terms here: www.ea.govt.nz/code-and-compliance/the-code/part-6-connection-of-distributedgeneration/schedule-6-2/ Unless otherwise mutually agreed with Vector, if your application to connect is successful you will be connected on the Regulated Terms of Schedule 6.2. Initial Application to Vector Our process for connecting distributed generation is governed by Part 6 of the Code. As part of this process, we will need you to complete our application form. This is available on our website. Please ensure you complete this application form correctly otherwise we will return your application form to you. If you have any other information that may help us with your application, please also include this with your application form. Further details about our contact details and application fees are available on page 11. Vector to discuss with you A Vector representative will contact you to discuss your initial application. We will then highlight any potential issues and provide information about our particular connection requirements. Key aspects Vector will want to discuss: Proposed location of your generator Specifications of your generator Proposed schedule for connection to the network Proposed design and installation contractors for your generator Technical implications of connecting your generator Commercial implications of connecting your generator Distributed Generation (>10kW) Vector Limited Page 9 of 14

Planning and scheduling Companies that will be involved in the design and installation process. Design in conjunction Once we have discussed the effects of your proposed generation installation, further investigation and design work needs to be undertaken by both Vector and your representatives. Ongoing discussion needs to occur to ensure the design process goes smoothly and an acceptable outcome is reached. Installation of distributed generation Once you have finalised your installation design, Vector will require a design review before approving connection of your system to our network. You must use a suitably qualified installer (a Registered Electrician or Certified Contractor) to install your generator and electrical wiring. You must send Vector a copy of the Certification of Compliance (CoC) that your installer must provide to you on completion. Final application and approval to proceed When you are ready to connect to Vector s network you need to notify Vector that your wish to proceed. We can then organise your final connection to our network. You must have obtained and provided to Vector: Certificate of Compliance (CoC) Sale/Purchase Agreement with an Electricity Retailer Payment for connection related costs Operating procedures Contact details and procedures All other information requirements All relevant information to allow us to update our network records Proposed connection schedule. Prior to connection, any network reinforcement projects must be completed (if required to allow connection to the network). Connection to Vector s electricity network Once Vector is satisfied that your generation system is compliant with all Vector and industry standards and requirements, connection to Vector s network can be organised. Final connection to Vector s network could require: Final system/site inspection and approval by a Vector representative. Applicable fees for this our outlined overleaf. Distributed Generation (>10kW) Vector Limited Page 10 of 14

Connection to the network by a Vector approved contractor. Update of Vector s Information Systems. Once connected to our network, unless otherwise mutually agreed with Vector, you will be connected on the Regulated Terms, as per Schedule 6.2 of Part 6, of the Code. (See above for link). Fees Upfront application fee It takes time for Vector to analyse and review the information that you provide. Vector will charge an initial application fee to help cover our costs. The application fee varies depending on the size of your connection and will be charged as follows: Connection size Application Fee >10kW and <100kW $500* 100kW and <1MW $1,000* 1MW $5,000* * In accordance with Schedule 6.5, under Part 6 of the Code. Upon receipt of an Initial Application, Vector will issue an invoice to the distributed generation applicant. The application will only proceed upon receipt of payment. On-site observation and testing fee Depending on the installation, Vector may require a site visit and inspection to ensure that we are satisfied with the installation. If Vector requires a site visit, we will charge a nominal fee to help cover the expenses we incur. These charges are as follows: Connection size Inspection Fee >10kW and <100kW $120* 100kW $1,200* * In accordance with Schedule 6.5, under Part 6 of the Code. Distributed Generation (>10kW) Vector Limited Page 11 of 14

Information requirements for distributed generation The following are the information requirements for distributed generation, and is extracted from Vector s Distribution Code. The Distribution Code is available on Vector s website, and must be read by anyone planning to install distributed generation on Vector s electricity network. Distribution Code - Appendix 4 INFORMATION REQUIREMENTS FOR DISTRIBUTED GENERATION 1. REQUIRED FOR ALL GENERATORS CONNECTED TO THE NETWORK 1.1 Generating Plant Data (i) Terminal volts (kv); (ii) Rated kva; (iii) Rated kw; (iv) Maximum active power sent out (kw max) reactive power requirements (kvar), if any; (v) Type of generating plant - synchronous, asynchronous, etc; (vi) Type of prime mover; (vii) Anticipated operating regime of generation eg, continuous, intermittent, peak lopping; (viii) Fault level contribution (for large machines, this may be covered by the details listed in section 2); (ix) Method of voltage control; (x) Generator transformer details, as applicable; and (xi) Requirements for top-up supplies and/or standby supplies. 1.2 Interface Arrangements (i) The means of synchronisation between the Distribution Network and the Generator; (ii) Details of arrangements for connecting with earth that part of the Generator s system directly connected to the distribution system; (iii) The means of connection and disconnection which are to be employed; (iv) Ability of plant to backfeed the external system; (v) Protection equipment and protection setting; and (vi) Precautions to be taken to ensure the continuance of safe conditions should any earthed neutral point of the Generator s system operated at HV become disconnected from earth. 2. INFORMATION REQUIRED FOR LARGE GENERATORS This section applies to distributed generators connected at voltages equal to or greater than 6.6kV or of capacity greater than 1 MW and details the technical and design information requirements not specifically covered above. The following information is required by Vector to determine the effect of the proposed generation on the network. 2.1 Technical Data Generating plant information (impedances p.u. on rating): Type of prime mover Distributed Generation (>10kW) Vector Limited Page 12 of 14

Rated MVA Rated MW Generator MW/MVAr capability chart (at terminals) Type of excitation system Inertia constant MW secs/mva (whole machine) Stator resistance Direct axis reactances Sub-Transient Transient Synchronous Quadrature axis reactances Sub-Transient Synchronous Time constants Direct axis Sub-Transient & Transient Quadrature Axis Open or short Sub-Transient (stating either circuit time constant) Zero sequence Resistance Reactance Negative sequence Resistance Reactance Generator transformer Resistance Reactance MVA Rating Tap arrangement Vector group Earthing (i) Automatic voltage regulator; (ii) A block diagram for the model of the AVR system including the data on the forward and feedback gains, time constants and voltage control limits; (iii) Speed governor and prime mover data; and (iv) A block diagram for the model of the generating plant governor detailing the governor flyball, if applicable, and system control and turbine time constants, together with the turbine rating and maximum power. 2.2 Interface Arrangements (i) The means of synchronisation between the Distribution Network and the Generator. (ii) Details of arrangements for connecting with earth that part of the Generator s system directly connected to the distribution system; (iii) The means of connection and disconnection which are to be employed; (iv) Ability of plant to backfeed external system; (v) Protection equipment and protection setting; and (vi) Precautions to be taken to ensure the continuance of safe conditions should any earthed neutral point of the Generator s system operated at HV become disconnected from earth. 2.3 Capacity and Standby Requirements (i) Registered capacity and minimum generation of each generating unit and power station in MW; Distributed Generation (>10kW) Vector Limited Page 13 of 14

(ii) Generating unit and power station auxiliary demand (active power and reactive power) in MW and MVAr, at registered capacity conditions. For Users with own generation, this should include top-up requirements; (iii) Generating unit and power station auxiliary demand (active power and reactive power) in MW and MVAr, under minimum generation conditions. For Users with own generation, this should include top-up and standby requirements. 3. FURTHER INFORMATION REQUIRED BY TRANSPOWER Generators with large machines may be subject to the Transpower Connection Code and central dispatch. Where this applies any information supplied to Vector, and also any further information requested by Transpower will be forwarded to Transpower. It will be the responsibility of the Generator to provide the information required to Vector. Vector will pass on the information to Transpower. There may also be information required under the terms of any Transpower contract in respect of the transfer of energy from the Generator to the Generator s Customer. Distributed Generation (>10kW) Vector Limited Page 14 of 14