TECHNICAL PROPERTIES OF THE APPLIANCE

Similar documents
gorenje GBFU SIMPLICITY

Installation and technical manual

Unvented Electric Water Heater 10/15 litre Undersink

Zen Boiling Tap Range

GETTING STARTED? EASY.

User Manual. Dishwasher ZDM17301SA ZDM17301WA

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

GETTING STARTED? EASY.

17 OPERATING AND INSTALLATION MANUAL - EN

OPERATING AND INSTALLATION MANUAL

FAVORIT34502VIO. EN User Manual

User manual. Dishwasher ZDI12001

GETTING STARTED? EASY.

GETTING STARTED? EASY.

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

FAVORIT 66609M0P FAVORIT 66609W0P. EN User Manual

CERAMIC FAN HEATER URBAN

The guarantee on this appliance is valid for 12 months from the first day of installation.

GETTING STARTED? EASY.

User manual. Dishwasher ZDT15002

Important Safeguards. Topic 2 SAVE THESE INSTRUCTIONS - FOR HOUSEHOLD USE ONLY SAVE THESE INSTRUCTIONS - FOR HOUSEHOLD USE ONLY 3

User Manual Dishwasher FAVORIT 56302MO FAVORIT 56302WO

OPERATING INSTRUCTIONS

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

Electronically controlled instantaneous water heater CEX 9. CEX9: C models. Instructions for the user

200W Frostwatch Radiant Heater Operation Manual

Get usage advice, brochures, trouble shooter, service information: Register your product for better service:

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

OPERATING AND INSTALLATION MANUAL

GETTING STARTED? EASY.

FAVORIT DISHWASHER USER MANUAL

Electronically controlled instantaneous water heater. DEX: C models. Instructions for the user

Operating and assembly manual: Electric instantaneous flow heater Admiral

User manual. Dishwasher ZDI12010XA

User manual. Dishwasher ZDF14001WA ZDF14001KA ZDF14001SA

MIX Boiler & Font Range Service Manual

OPERATING AND INSTALLATION MANUAL

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

ESL 5201LO EN DISHWASHER USER MANUAL

FAVORIT VI DISHWASHER USER MANUAL

ESF5202LOW. EN Dishwasher User Manual

wc431 Slimline Integrated Dishwasher Manual for Installation, Use and Maintenance

User Manual Dishwasher FAVORIT 66602VI0P

User manual. Dishwasher ZDT15010FA

VAPORELLA. Fig. 1 Fig. 2. Fig. 3 Fig. 4

Operating instructions

ESL5205LO. EN Dishwasher User Manual

WC600 Integrated Dishwasher Installation, Use and Maintenance

MW402 Integrated Dishwasher

ENAMELED INDIRECT WATER HEATERS

MW401 Integrated Dishwasher

GETTING STARTED? EASY.

User Manual Dishwasher F55412VI0

Manual for installation, use and maintenance MW200. Integrated Slimline Dishwasher. year. parts + 1 year labour guarantee.

OPERATING AND INSTALLATION MANUAL

/04.14_00. De Longhi Appliances via Seitz, Treviso Italia

User Manual Dishwasher F55402VI0P

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH

user manual Dishwasher ESL 46510

OPERATING AND INSTALLATION MANUAL

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

INSTRUCTIONS AND WARRANTY

User Manual. Dishwasher IDSH604W

CONTENTS QUICK REFERENCE GUIDE INSTRUCTIONS FOR USE PROGRAMME CHART BOOKLET

Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg

AQUA PREMIER ELECTRONIC ELECTRIC SHOWER. Installation and User Guide

U V S R2 W INSTRUCTION MANUAL ENGLISH G H PRINTED IN P.R.C /01

Mix Boiler & Font Range ( #, #, #, , )

SHOWER WATER HEATER MODEL X-SLIM 35 EC / X-SLIM 45 EC OPERATION AND INSTALLATION INSTRUCTIONS

Suits all KPF849 models

Moisture inside the drum is due to final testing.

AQUARIUS 45 MARINE SERVICE MANUAL

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

TH100 Three in One Instant Hot Water Tap

User and maintenance manual

INSTRUCTIONS AND WARRANTY

FRANKE MINERVA 3-IN-1 HOT WATER TAP HEATING TANK INSTALLATION GUIDE

User manual. Dishwasher ZDTS102. Downloaded from manuals search engine

2400W steam generator with one touch temperature control. Instruction Manual MODEL: SI9020TTN

KOSPEL S.A KOSZALIN UL. OLCHOWA 1

GLASS HEATER OWNER S MANUAL. Model No. GH-15A

Owner s Manual READ AND SAVE THESE INSTRUCTIONS

Powerflow Unvented water heater

DIGITAL MODULATING BOILERS

Akva Vita Instantaneous water heater

Polti S.p.A. reserves the right to change equipment or accessory specification without prior notice.

30 Misting/Oscillating Fan Model Number 01030

Installation Guide COMBI. Before installing read this guide first

INSTANTANEOUS ELECTRIC SHOWER

WC141 Integrated Dishwasher Installation, Use and Maintenance

Operating instructions

Colorado SCR. Electric Towel Radiator Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

GETTING STARTED? EASY.

FAVORIT 55200VI EN DISHWASHER USER MANUAL

Electrical Mini Tank Water Heater anual, and Warranty nformation

KYROS INSTALLATION MANUAL KYROS. Digital Electric Water Heater Wall-hung Unvented

INSTRUCTIONS AND WARRANTY

INSTALLATION MANUAL GUTHD2. Universal Two Way Digital Thermostatic Valve for Shower Systems

Transcription:

TGR 30-120 SM

EN Dear buyer, thank you for purchasing our product. Prior to the installation and first use of the electric water heater, please read these instructions carefully. THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING CHILDREN) WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES, OR LACK OF EXPERIENCE AND KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTIONS CONCERNING THE USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY. CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE. In accordance with the latest guidelines, we have developed for our more demanding customers the electric water heater TGR equipped with an intelligent electronic regulator allowing the setting of the temperature of water in the heater as well as smart "ECO S " mode of operation. The heater records your habits and after a while, it calculates the optimal operating mode that enables minimal use of electric energy necessary to meet your warm water needs. This water heater has been manufactured in compliance with the relevant standards and tested by the relevant authorities as indicated by the Safety Certificate and the Electromagnetic Compatibility Certificate. The technical characteristics of the product are listed on the label affixed between the inlet and outlet pipes. The installation must be carried out by qualified staff. All repairs and maintenance work within the water heater, e.g. lime removal or inspection/replacement of the protective anticorrosion anode, must be carried out by an authorised maintenance service provider. INSTALLATION The water heater shall be installed as close as possible to the outlets. When installing the water heater in a room with a bathtub or shower, take into account the requirements defined in IEC Standard 60364-7-701 (VDE 0100, Part 701). It has to be fitted to the wall using appropriate wall screws with a minimum diameter of 8 mm. A wall with a poor loadbearing capacity must be properly reinforced where the heater will be installed. The water heater may only be fixed upon the wall vertically. We recommend the distance between the water heater and the ceiling is large enough to allow simple replacement of the MG anode (see dimension G in the Installation Drawing), in order to avoid unnecessary dismounting of the heater during the servicing intervention. TECHNICAL PROPERTIES OF THE APPLIANCE Type TGR 30 SM TGR 50 SM TGR 80 SM TGR 100 SM TGR 120 SM Volume [l] 30 50 80 100 120 Rated pressure [MPa (bar)] 0,6 (6) / 0,9 (9) Weight / Filled with water [kg] 20/50 24/74 30/110 34/134 38/158 Anti-corrosion of tank enamelled & Mg Anode Power of electrical heater [W] 2000 Connection voltage [V~] 230 Protection class I Degree of protection IP24 Duration of heating to 75 C 1) [h] 1 05 1 55 3 05 3 55 4 35 Quantity of mixed water at 40 C [l] 50 89 145 200 236 Energy consumption 2) [kwh/24h] 0,90 1,32 1,85 2,20 2,60 1) Time for heating the whole content of heater if the initial temperature of cold water from water supply is 15 C. 22

2) Energy consumption to maintain the temperature of water in the water heater at 65 C if the surrounding temperature is 20 C, measured according to EN 60379. EN A B C G TGR 30 SM 476 275 173 80 TGR 50 SM 578 365 185 130 TGR 80 SM 783 565 190 180 TGR 100 SM 943 715 200 260 TGR 120 SM 1098 865 205 260 300-350 100 100 B C 454 G A Connection and installation dimensions of the water heater [mm] 461 G 1/2 CONNECTION TO THE WATER SUPPLY The water heater connections for the inlet and outlet of water are colour-coded. The inlet of cold water is marked with blue colour, while the hot water outlet is marked with red colour. The water heater can be connected to the water supply in two ways. The closed-circuit pressure system enables several points of use, while the open-circuit gravity system enables a single point of use only. The mixer taps must also be installed in accordance with the selected installation mode. The open-circuit gravity system requires the installation of a non-return valve in order to prevent the water from draining out of the tank in the event of the water supply running dry or being shut down. This installation mode requires the use of a cross-flow mixer tap. As the heating of water expands its volume, this causes the tap to drip. The dripping cannot be stopped by tightening it further; on the contrary, the tightening can only damage the tap. The closed-circuit pressure system requires the use of pressure mixer taps. For safety reasons the supply pipe must be fitted with a safety valve or alternatively, a valve of the safety class that prevents the pressure in the tank from exceeding the nominal pressure by more than 0.1 MPa (1 bar). The outlet opening on the relief valve must be equipped with an outlet for atmospheric pressure. The heating of water in the heater causes the pressure in the tank to increase to the level set by the safety valve. As the water cannot return to the water supply system, this can result in dripping from the outlet of the safety valve. The drip can be piped to the drain by installing a catching unit just below the safety valve. The drain installed below the safety valve outlet must be piped down vertically and placed in an environment that is free from the onset of freezing conditions. In case the existing plumbing does not enable you to pipe the dripping water from the safety valve into the drain, you can avoid the dripping by installing a 3-litre expansion tank on the inlet water pipe of the boiler. In order to provide correct operation of the safety valve, periodical inspections of the relief valve must be carried out by the user to eliminate any limescale and check if the safety valve is blocked. To check the valve, open the outlet of the safety valve by turning the handle or unscrewing the nut of the valve (depending on the type of the valve). The valve is operating properly if the water comes out of the nozzle when the outlet is open. 23

EN 8 1 7 2 3 6 4 5 3 5 Closed (pressure) system Legend: 1 - Safety valve 2 - Test valve 3 - Non-return valve 4 - Pressure reduction valve 5 - Closing valve Open (non-pressure) system 6 - Checking fitting 7 - Funnel with outlet connection 8 - Expansion tank H - Cold water T - Hot water Between the water heater and safety valve, no closing valve may be built in because it could impede the function of the safety valve. The heater can be connected to the domestic water supply network without a pressurereducing valve if the pressure in the network is lower than the nominal pressure. If the pressure in the network exceeds the nominal pressure, a pressure-reducing valve must be installed. Before connecting it to the power supply, the water heater must be filled with water. When filling the heater for the first time, the tap for the hot water on the mixing tap must be opened. When the heater is filled with water, the water starts to run through the outlet pipe of the mixing tap. CONNECTING THE WATER HEATER TO THE POWER SUPPLY NETWORK Before connecting to the power supply network, install a power supply cord in the water heater, with a min. diameter of 1.5 mm 2 (H05VV-F 3G 1.5 mm 2 ). To do this, the protective plate must be removed from the water heater. Connecting the heater to the power supply network must take place in accordance with the standards for electric appliances. To comply with the national installation regulations, an all poles disconnect switch must be installed between the water heater and the power supply network. When the heater is connected to the power supply, both lights on the front panel will light up for 2 seconds. Legend: 230 V~ N L 2 1 - Connection terminal 2 - Electronic regulator and bipolar thermal cut-out 3 - Electric heating element 3 L - Live conductor N - Neutral conductor 24 - Earthing conductor Electric installation

CAUTION: Before any intervention into the interior of the water heater, disconnect it from the power supply network! OPERATION AND MAINTENANCE After connecting to the water and power supply, the heater is ready for use. The heater is equipped with an electronic regulator that enables the setting of the temperature of water, adjustment of the heater s operation to your habits ("ECO S " programme) and troubleshooting application. OPERATION The water heater is operated by turning the regulation knob to the desired level. EN Switching on/off the heater To switch on the heater, turn the knob in the clockwise direction to reach the desired temperature level. To switch off the heater, turn the knob to the "0" position (if the heater is disconnected from the power supply, water must be drained from it in case of danger of freezing). Temperature setting The desired temperature level is set by turning the knob in the clockwise direction. ECO S - Temperature depends on the recorded needs of the user. ECO - Protection against freezing, temperature around 10 C. - Water temperature around 35 C. - Water temperature around 55 C. - Water temperature around 75 C. The operation of the heater in the "ECO S " mode This mode of operation is suitable if your hot water consumption habits are relatively consistent (example: taking a shower at approximately the same time of the day). Your habits are recorded and then taken into account when heating the water. The operation of the heater in the "ECO S " mode reduces the consumption of electric energy. The "ECO S " mode of operation can be switched on by twisting the control knob counter clockwise. The green and red light start simultaneously. The red light symbolises the functioning of the heater and the green light symbolises the ECO S mode. The "ECO S " function is based on a 7-day cycle. During the first week of operation, the water temperature in the heater is maintained at 75 C and the programme records the 25

EN consumption pattern for seven consecutive days. After that, the recorded pattern starts to be used automatically and the heater prepares the hot water based on the measurements from the previous week. At the same time, the heater continues to record the consumption. If the pattern differs from the previous week in terms of time or volume, the newly recorded pattern is used the following week. The water temperature in the "ECO S " mode is kept between 40 C and 75 C. When no consumption is anticipated (standby temperature), the water is maintained at 40 C. If, during recording, there was a power failure or the heater was switched off, the recording is not valid. The "ECO S " mode can be turned off by twisting the control knob to any other position. Anti-legionella function The function is factory set. After connecting to the power supply or after eliminating an error, the anti-legionella function is switched on after 3 days. When the heater is switched on and the temperature of the water in the heater is above 62 C continuously for 15 minutes, the countdown is finished. As soon as the temperature falls below 62 C, a 30-day countdown begins again. If within 30 days the heater does not reach 62 C, the anti-legionella function is switched on and the heater heats the water to the temperature of 62 C for 15 minutes. If the heater is not switched on or connected to the power supply and the 30-day period expires, the anti-legionella function does not switch on until the heater is turned on. If the anti-legionella function is in operation and the user switches off the heater, the function is interrupted and a new 30-day countdown begins. If the user lowers the set temperature during the operation of the anti-legionella functions, the function is interrupted and a new 30-day countdown begins. Error indication In case of an error or warning on the heater, red and green light start blinking to indicate an error according to the table below. STATUS RED light GREEN light Normal operation Heater switched off / / Heater switched on, no error, heater not operating / / Heater switched on, no error, heater operating GLOWING / Operation in ECO S mode Heater switched on, no error, heater not operating / GLOWING Heater switched on, no error, heater operating GLOWING GLOWING Heater switched on, temp. sensor error (sensor 1 or sensor 2 in short circuit or open circuit, temp. difference error) ERRORS (Call the service) BLINKING BLINKING Heater switched on, heater warning BLINKING BLINKING 26

When the water heater is not in use for a longer period of time and is switched off or disconnected from the power supply, it must be emptied in case of danger of freezing. Water from the heater is drained through the inlet pipe of the heater. For this purpose, a special fitting (T-fitting) must be mounted between the relief valve and the heater inlet pipe, or a discharge tap. The heater can be discharged directly through the relief valve, by rotating the handle or the rotating valve cap to the same position as for checking the operation. Before discharge, make sure the heater is disconnected from the power supply, and open the hot water on the connected mixer tap. After discharging through the inlet pipe, there is still some water left in the water heater. The remaining water will be discharged after removing the heating flange, through the heating flange opening. The external parts of the water heater can be cleaned with a mild detergent solution. Do not use solvents and abrasives. Regular preventive maintenance inspections ensure faultless performance and long life of your heater. The first of these inspections should be carried out by the authorised maintenance service provider about two years from installation in order to inspect the wear of the protective anticorrosion anode and remove the lime coating and sediment as required. The lime coating and sediment on the walls of the tank and on the heating element is a result of quality, quantity and temperature of water flowing through the water heater. The maintenance service provider shall also issue a condition report and recommend the approximate date of the next inspection. Never try to repair any possible faults of the water heater by yourself, but inform about it the nearest authorised service workshop. EN 27

Gorenje 09/2012 394801