USER GUIDE LOGIC HEAT H

Similar documents
System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

Logic+ Combi

USER GUIDE VOGUE MAX SYSTEM

USERS GUIDE 24, 30. For installation guide see reverse of book

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

USERS GUIDE. LOGIC+ Combi 24, 30, 35

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

GB24 & GB30. User Manual

WARMCAIR. Condensing Air & Water Heater. High Efficiency Downflow Condensing Air & Water Heater USERS INSTRUCTIONS

2 Minimiser SE - User's

Open Vented Condensing Boilers

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

User's Instructions. Alpha CB50

Baxi Maxflow Combi WM

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

Format System 25 HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

Baxi Maxflow Combi FS

User Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe.

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

With a power output ranging from 13kW to 24kW, they provide the flexible answer for the majority of traditional installation scenarios.

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Osprey 2 CFL

iheat 25c iheat 30c iheat 35c

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY

condens Instructions for Use Betacom 2 24 G.C. No Betacom 2 28 G.C. No

Greenstar 12i/24i System

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No.

GREENSTAR i SYSTEM USER MANUAL WALL HUNG RSF GAS FIRED CONDENSING SYSTEM BOILER FOR CENTRAL HEATING SYSTEMS UK/IE (2013/08)

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

USERS GUIDE. Electronic Timer, 7 day. LOGIC+ Combi, LOGIC Combi & LOGIC Combi E 24, 30, 35

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Maximiser SE. USER S INSTRUCTIONS Natural gas only INSTALLER: TELEPHONE:

MURELLE EV HE 25/55-30/55

The guarantee on this appliance is valid for 12 months from the first day of installation.

Performa 24. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Greenstar 25Si/30Si USER INSTRUCTIONS & CUSTOMER CARE GUIDE

MERIDIAN HE 30 C. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

24CDi, 28CDi & 35CDi II COMBI

Greenstar 12i system / 24i system

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

GREENSTAR Ri USER INSTRUCTIONS UK/IE WALL HUNG RSF GAS FIRED CONDENSING REGULAR BOILER FOR CENTRAL HEATING SYSTEMS a (2010/10)

Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit

USER INSTRUCTIONS & CUSTOMER CARE GUIDE HIGHFLOW 400 ELECTRONIC SERIES

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

GREENSTAR Ri ErP. User instructions UK/IE. Wall hung RSF gas fired condensing regular boiler. For central heating systems

WALL HUNG RSF GAS FIRED CONDENSING REGULAR BOILER

Vote for your Installer of the year at HEATSLAVE

GREENSTAR HIGHFLOW 440/550CDi

Grant Vortex. Boiler House Floor Standing Condensing Oil Boiler Range User Handbook. Model shown: VTXBH3646

Operating instructions

AquaNova. Water heater. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

GREENSTAR i JUNIOR USER INSTRUCTIONS UK/IE WALL HUNG RSF GAS FIRED CONDENSING COMBINATION BOILER

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

Linea HE. High efficiency combi boiler. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

Combi Eco Elite Range. User s Guide and Important Warranty Information

Operating instructions

WALL HUNG RSF GAS FIRED CONDENSING COMBINATION BOILER GREENSTAR 24i Junior/28i Junior

DANESMOOR FRONT SERVICE (FS) 12-18, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Statesman 45/50L, 50/70L, 70/90L, 90/110L, Utility 50/70L, 70/90L, 90/110L, 110/130L, 130/150L

GREENSTAR CDi CLASSIC REGULAR ErP

Powermax HE 85, 115 & 150 Litre Condensing Boilers with Integrated Hot Water Storage

VIESMANN. Operating instructions VITODENS 100-W. for the system user

Operating instructions

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler

Greenstar 24i junior / 28i junior

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler

User Manual for model

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

Mikrofill Ethos Condensing combination boiler

VIESMANN. Operating instructions VITODENS 111-W. for the system user

GREENSTAR HIGHFLOW 440/550CDi

/2005 GB(EN) For the user. Wall-mounted condensing gas combi boiler Buderus /C, /C

Index BEFORE USING THE APPLIANCE Safety Instructions... 2 Recommendations... 3 Switching On the Appliance... 4 HOW TO OPERATE THE FREEZER...

User Guide. Platinum Combi Gas Fired Wall Mounted Condensing Combination Boiler

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler

User Manual for model RK 18 RK 25 RK 34 CE 0694 RK 18_25_34 - RAD - ING - MAN.UT A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

User s Information Manual

GREENSTAR Ri ErP + User instructions UK/IE. Wall hung RSF gas fired condensing regular appliance. For central heating systems

condens Instructions for Use Ultracom 2 35 Store G.C. No

User Guide. Promax SL Condensing Central Heating Boiler

GREENSTAR HEATSLAVE II ErP+ 12/18, 18/25 & 25/32

User Guide. EcoBlue Advance Heat Gas Fired Wall Mounted Condensing Boiler

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

OWNER S GUIDE ETERNITY. MODEL 540C (GC No ) INSET BALANCED FLUE GAS FIRE

Greenstar FS 30CDi ErP & 42CDi ErP Regular

Transcription:

USER GUIDE LOGIC HEAT H 12 15 18 24 30 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Ideal. For the very latest copy of literature for specification and maintenance practices visit our website www.idealboilers.com where you can download the relevant information in PDF format. For alternative languages in our User Guides please visit our website www.idealboilers.com. October 2017 UIN 215354 A06

CONTENTS 1. Introduction... 2 Safety... 2 Electricity Supply... 2 Important Notes... 2 2. Boiler Operation... 3 Controls Diagram... 3 To Start the Boiler... 3 Control of Water Temperature... 3 Efficient Heating System Operation... 3 Weather Compensation... 3 Boiler Frost Protection... 3 Boiler Restart... 3 Mains Power Off... 3 3. Condensate Drain... 4 4. General Information... 4 Minimum Clearances... 4 Escape of Gas... 4 Cleaning... 4 Maintenance... 4 5. Points for the Boiler User... 5 Troubleshooting... 5 6. Normal Operation Display Codes... 5 7. Fault Codes... 6 1. INTRODUCTION The Logic Heat H is a heating only boiler, featuring full sequence automatic spark ignition and fan assisted combustion. It is designed to provide central heating and hot water when separate hot water cylinder is installed. Due to the high efficiency of the boiler, condensate is produced from the flue gases and this is drained to a suitable disposal point through a plastic waste pipe at the base of the boiler. A condensate plume will also be visible at the flue terminal. SAFETY Current Gas Safety (Installation & Use) Regulations or rules in force. In your own interest, and that of safety, it is the law that this boiler must be installed by a Gas Safe Registered Engineer, in accordance with the above regulations. In IE, the installation must be carried out by a Registered Gas Installer (RGII) and installed in accordance with the current edition of I.S. 813 Domestic Gas Installations, the current Building Regulations and reference should be made to the current ETCI rules for electrical installation. It is essential that the instructions in this booklet are strictly followed, for safe and economical operation of the boiler. ELECTRICITY SUPPLY This appliance must be earthed. Supply: 230 V ~ 50 Hz. The fusing should be 3A. IMPORTANT NOTES This appliance must not be operated without the casing correctly fitted and forming an adequate seal. If the boiler is installed in a compartment then the compartment MUST NOT be used for storage purposes. If it is known or suspected that a fault exists on the boiler then it MUST NOT BE USED until the fault has been corrected by a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII). Under NO circumstances should any of the sealed components on this appliance be used incorrectly or tampered with. This appliance can be used by children 8 years and above. Also persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, provided they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. All Gas Safe Register installers carry a Gas Safe Register ID card, and have a registration number. Both should be recorded in the Benchmark Commissioning Checklist. You can check your installer by calling Gas Safe Register direct on 0800 4085500. Ideal Boilers is a member of the Benchmark scheme and fully supports the aims of the programme. Benchmark has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety and efficiency. THE BENCHMARK SERVICE INTERVAL RECORD MUST BE COMPLETED AFTER EACH SERVICE 2 User s

2. BOILER OPERATION Legend A. Central Heating Temperature Knob B. Mode Knob C. Boiler Status D. Burner on Indicator E. Central Heating Economy Setting F. RESTART Button G. Function Button BOILER OFF BOILER ON ºC e ON MIN MAX RESTART B C G D F A E TO START THE BOILER If a programmer is fitted refer to separate instructions for the programmer before continuing. Start the boiler as follows: 1. Check that the electricity supply to boiler is off. 2. Set the mode knob (B) to BOILER OFF. 3. Set the Central Heating temperature knob (A) to MAX. 4. Switch on electricity to the boiler and check that all external controls, e.g. programmer, room thermostat and hot water cylinder thermostat are on. 5. Set the mode knob (B) to BOILER ON. The boiler will commence ignition sequence, supplying heat to the central heating, if required. Note. In normal operation the boiler status display (C) will show codes: 00 Standby - no demand for heat. Central Heating being supplied FP Boiler frost protection - boiler will fire if temperature is below 5ºC. During normal operation the burner on indicator (D) will remain illuminated when the burner is lit. Note: If the boiler fails to light after five attempts the fault code will be displayed (refer to Fault Code page). To Turn Off Set the mode knob (B) to BOILER OFF. CONTROL OF WATER TEMPERATURE The boiler controls the central heating radiator temperature to a maximum of 80 o C, adjustable via the central heating temperature knob (A). Approximate temperatures for central heating: Knob Setting Central Heating Radiator Temperature (approx.) Minimum 30ºC Maximum 80ºC For economy setting Operation. refer to Efficient Heating System EFFICIENT HEATING SYSTEM OPERATION The boiler is a high efficiency, condensing appliance which will automatically adjust its output to match the demand for heat. Therefore gas consumption is reduced as the heat demand is reduced. The boiler condenses water from the flue gases when operating most efficiently. To operate your boiler efficiently (using less gas) turn the central heating temperature knob (A) to the position or lower. In winter periods it may be necessary to turn the knob towards the MAX position to meet heating requirements. This will depend on the house and radiators used. Reducing the room thermostat setting by 1ºC can reduce gas consumption by up to 10%. WEATHER COMPENSATION When the Weather Compensation option is fitted to the system then the central heating temperature knob (A) becomes a method of controlling room temperature. Turn the knob clockwise to increase room temperature and anti-clockwise to decrease room temperature. Once the desired setting has been achieved, leave the knob in this position and the system will automatically achieve the desired room temperature for all outside weather conditions. BOILER FROST PROTECTION If the system includes a frost thermostat then, during cold weather, the boiler should be turned OFF at the programmer (if fitted) ONLY. The mains supply should be left switched ON, with the boiler thermostat left in the normal running position. If no system frost protection is provided and frost is likely during a short absence from home it is recommended to leave the heating controls (if fitted) at a reduced temperature setting. For longer periods, the entire system should be drained. BOILER RESTART To restart the boiler, when directed in the listed fault codes (see section 7) press the RESTART button (F). The boiler will repeat its ignition sequence. If the boiler still fails to start consult a Gas Safe Registered Engineer or an IE Registered Gas Installer (RGII). MAINS POWER OFF To remove all power to the boiler the mains power switch must be turned off. User s 3

3. CONDENSATE DRAIN This appliance is fitted with a siphonic condensate trap system that reduces the risk of the appliance condensate from freezing. However should the condensate pipe to this appliance freeze, please follow these instructions: a. If you do not feel competent to carry out the defrosting instructions below please call your local Gas Safe Registered installer for assistance. b. If you do feel competent to carry out the following instructions please do so with care when handling hot utensils. Do not attempt to thaw pipework above ground level. If this appliance develops a blockage in its condensate pipe, its condensate will build up to a point where it will make a gurgling noise prior to locking out an L 2 fault code. If the appliance is restarted it will make a gurgling noise prior to it locking out on a failed ignition L 2 code. To unblock a frozen condensate pipe; 1. Follow the routing of the plastic pipe from its exit point on the appliance, through its route to its termination point. Locate the frozen blockage. It is likely that the pipe is frozen at the most exposed point external to the building or where there is some obstruction to flow. This could be at the open end of the pipe, at a bend or elbow, or where there is a dip in the pipe in which condensate can collect. The location of the blockage should be identified as closely as possible before taking further action. 2. Apply a hot water bottle, microwaveable heat pack or a warm damp cloth to the frozen blockage area. Several applications may have to be made before it fully defrosts. Warm water can also be poured onto the pipe from a watering can or similar. DO NOT use boiling water. 3. Caution when using warm water as this may freeze and cause other localised hazards. 4. Once the blockage is removed and the condensate can flow freely, restart the appliance. (Refer to To Start the boiler ) 5. If the appliance fails to ignite, call your Gas Safe Registered engineer. Preventative solutions During cold weather, set the central heating temperature knob (A) to maximum must return to original setting once cold spell is over). Place the heating on continuous and turn the room thermostat down to 15ºC overnight or when unoccupied. (Return to normal after cold spell). 4. GENERAL INFORMATION MINIMUM CLEARANCES Clearance of 165mm above, 100mm below, 2.5mm at the sides and 450mm at the front of the boiler casing must be allowed for servicing. Bottom Clearance Bottom clearance after installation can be reduced to 5mm This must be obtained with an easily removable panel to provide the 100mm clearance required for servicing. ESCAPE OF GAS Should a gas leak or fault be suspected contact the National Gas Emergency Service without delay. Telephone 0800 111 999. Ensure that; - All naked flames are extinguished - Do not operate electrical switches - Open all windows and doors CLEANING For normal cleaning simply dust with a dry cloth. To remove stubborn marks and stains, wipe with a damp cloth and finish off with a dry cloth. DO NOT use abrasive cleaning materials. MAINTENANCE The appliance should be serviced at least once a year by a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII). 4 User s

5. POINTS FOR THE BOILER USER Note. In line with our current warranty policy we would ask that you check through the following guide to identify any problems external to the boiler prior to requesting a service engineers visit. Should the problem be found to be other than with the appliance we reserve the right to levy a charge for the visit, or for any pre-arranged visit where access is not gained by the engineer. TROUBLESHOOTING NO CENTRAL HEATING OR HOT WATER Check the mains power is turned on and ensure mode knob (B) is in the BOILER ON position Check the Programmer (external to the boiler) is in an ON position, and the room thermostat is turned up Does the boiler operate and provide central heating? YES Check the time settings on the programmer are as you require and adjust if necessary NO See boiler Operation Modes and Fault Codes section. If 0 0 is displayed then contact a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII) FOR ANY QUERIES PLEASE RING THE IDEAL CONSUMER HELPLINE : 01482 498660 NOTE. BOILER RESTART PROCEDURE - To restart boiler, press the RESTART button User s 5

6. NORMAL OPERATION DISPLAY CODES DISPLAY CODE ON BOILER 00 DESCRIPTION The boiler is in standby operation awaiting either a central heating call or hot water demand. ON ON 54 54 FP - - o C o C The boiler has a call for central heating but the appliance has reached the desired temperature set on the boiler. The boiler is operating in central heating / hot water mode. The boiler is operating in frost protection. The boiler mode knob (B) is in the off position, rotate fully clockwise for hot water and central heating operation. 6 User s

7. FAULT CODES DISPLAY CODE ON BOILER DESCRIPTION ACTION F 2 F 3 F 4 L 4 Flame Loss Fan Fault Flow Thermistor 1. Check other gas appliances in the house are working to confirm a supply is present in the property. 2. If other appliances do not work or there are no other appliances, check the gas supply is on at the meter and/or pre payment meter has credit. If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). Restart the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). Restart the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). F 5 L 5 Return Thermistor Restart the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). F 6 Outside Sensor Failure Restart the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). F 7 Low Mains Voltage Contact a qualified electrician or your electricity provider. F 9 L 9 Unconfigured PCB Unconfigured PCB or gas valve short circuit. Please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). F 8 L 8 F A Flow / Return Reversed Please contact a Gas Safe Registered Engineer. In IE contact a Registered Gas Installer (RGII). F 8 No Water Flow Please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). L 1 Flow Temperature Overheat or No Water Flow Check system water pressure is between 1 & 1.5bar on the system pressure gauge. To re-pressurise the system see Section 4. If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). L 2 Ignition Lockout 1. Check condensate Pipe for blockages (refer to Section 3) 2. Check other gas appliances in the house are working to confirm a supply is present in the property. 3. If other appliances do not work or there are no other appliances, check the gas supply is on at the meter and/or pre payment meter has credit. If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). L 6 False Flame Lockout Restart the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). L C F U 5 Boiler Resets in 15 minutes 1. Turn electrical supply to boiler off and on. Flow/Return Differential > 50 C 2. If the boiler fails to operate please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). User s 7

NOTES 8 User s

NOTES User s 9