UL/FM Fire Protection Products Setting the Standard

Similar documents
UL/FM Fire Protection Products Setting the Standard

UL/FM Fire Protection Products. Reliable fire protection products for your commercial, industrial, or institutional property.

UL/FM Fire Protection Products. Reliable fire protection products for your commercial, industrial, or institutional property.

UL/FM Fire Protection Products

Flow Control for Fire Protection

ISO9001:2008 Cert Certified FIRE HYDRANTS. since SFFECO

Flow Control for Fire Protection

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

F4060 RESILIENT SEATED GATE VALVES

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts

BS 5163 EN 1074 EN 1171 ISO 7259 AS 2638 FM UL

Essex County College - West Essex Campus Addition And Renovations dlb # / 11-14

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

INFACT CORPORATION WATERWORKS PRODUCTS FLEX REDUCER SPECIFICATION S TOLL FREE:

Full-line Product Overview

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y VTP. Vertical Turbine Pump

Port of St Helens SIA Aircraft Hanger Scappoose, OR

PLUMBING HEATING GAS INDUSTRIAL ACTUATION HYDRONICS COMMITMENT TO QUALITY SPECIFICATIONS

SECTION FIRE PROTECTION

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

Worldwide Contacts. Technical Data

Technical Data. Sizes 2 12 Inch (DN50 DN300)

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Model G5 Series Sprinkler Summary. Listings and Approvals. G4/G5 QR Gasket culus QR G4/G5 SR Gasket culus, FM SR G4/G5

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

Facility Fire-Suppression Water-Service Piping

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

A. This section includes design and performance information for fire protection and suppression systems.

HYDRO-GUARD HG-1-BASIC/S ATMOSPEHERIC DISCHARGE DEVICE CONSTRUCTION FOR ABOVE GROUND INSTALLATIONS 1. GENERAL DESCRIPTION 2.

2016 CDM Smith All Rights Reserved July 2016 SECTION FIRE PROTECTION - SPRINKLER AND STANDPIPE SYSTEMS

CONTRACT FOR USE OF FIRE PROTECTION SYSTEM

Engineered Basins Affordable, effective pressure sewer system Rocky, hilly, wet and flat topography Dependable, reliable and cost effective

DIVISION 21 FIRE SUPPRESSION FIRE SUPRESSION

Goulds Large Capacity, Single Stage, Double Suction Pump

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

B. Related Sections: The following Sections contain requirements that relate to this Section.

Series 20 Dual Check Backflow Preventers

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. Open Impeller ASME (ANSI) B73.1 Pump for continuous use in Chemical Process Services

SPRINKLERS TABLE OF CONTENTS

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers

DIVISION 21 FIRE SUPPRESSION FIRE SUPPRESSION GENERAL PROVISIONS .1 PREPARATION OF CONTRACT DOCUMENTS

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

Orange Township Fire Department Fire Prevention Bureau

SECTION DOMESTIC WATER PIPING SPECIALTIES

KEENER GRINDER PUMPS

SIHI multi Modular multistage pumps

MARLOW PUMPS RECIRCULATION

WL User Manual. Innovative Technology for a Connected World. global solutions: local support TM

Technical Data. Sizes: ANSI Inches (DN) 2-1/2 (DN65), 3 (DN80), 4 (DN100), 5 (DN125), 6 (DN150), 8 (DN200), 10 (DN250)

SECTION DRY-PIPE SPRINKLER SYSTEMS

WHY SULLAIR? For more information on the IHI-Sullair joint venture, please visit 2,000th IHI-Sullair centrifugal

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

Lubrication Tools and Equipment Portable Oil Drains

Oxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805)

SECTION SECTION DESIGN REQUIREMENTS

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

Anvil International is the largest and most complete fitting and hanger manufacturer in the world. TODAY

5. CONDENSATE PUMPS/UNITS

SECTION FIRE-SUPPRESSION STANDPIPES

Aeon International Ltd Blenheim House, Falcon Court Preston Farm Industrial Estate Stockton on Tees TS18 3TS, United Kingdom

A. This Section includes the following domestic water piping specialties:

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

DARTMOUTH COLLEGE DESIGN November 15, 2007 & CONSTRUCTION GUIDELINES

Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies

Taco 00 Series Cartridge Circulators

DIVISION 21 - FIRE SUPPRESSION

Troubleshooting the MPH 24FP Series Pedestal Hydrant

PERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers

DURA RIMP. Goodall Duracrimp coupling system: INFERNO ISO A and SUPER INFERNO. A safe crimping connection for our GOODALL steamhoses

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

FAIRBANKS NIJHUIS SOLIDS HANDLING PUMPS.

Used Fluid Handling Portable Used-Oil Gravity Drains

DIVISION 21 - FIRE SUPPRESSION

BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS. Product Submittal A PART OF

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

esfr dry pendent sprinkler Vk502 (k14.0)

BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP. ...world leaders in heat transfer technology

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

ES-6. Encapsulated Rotary Screw Air Compressors. 4 7 kw 5 10 hp

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

UC Santa Cruz Campus Design Guide. Includes the following sections: None DESIGN REQUIREMENTS

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

Used Fluid Handling Portable Used Oil Gravity Drains

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for UL and FM Listing/Approval requirements that must be followed.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

TECHNICAL DATA OBSOLETE

569, 570, 571, 572 Series

CLOSED COUPLED CENTRIFUGAL PUMPS

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

Transcription:

UL/FM Fire Protection Products Setting the Standard

Markets Power Institutional Company Overview Mueller Co. is a leader in high-quality commercial and institutional fire protection products, offering a broad range of carefully designed, durable, reliable and easily maintained fire protection products compliant to UL/FM requirements. Plus, all Mueller Co. products are backed by the company s expert technical support, superior service, and ready parts availability. Mueller Co. UL/FM fire protection products set the standard for performance and reliability year after year. Mueller Water Distribution Products are available through Authorized Mueller Stocking Distributors in all parts of the United States, and are sold around the world through qualified distributors and representatives. Mueller Co. s flow control and fire protection products are used in the building and maintenance of infrastructure. This includes Power, Institutional, Oil & Gas, Chemical and more. Oil & Gas Core Values Mueller Co. has a set of Core Values to help us think, act and work together to benefit all of our stakeholders from our employees who are our most valued assets, to our customers who expect quality products and service. These Core Values are not an end in themselves. Rather, they form the foundation of our culture, define behaviors required of us all and guide our decision making. Chemical As a company and as individuals, we will: Act with integrity do the right thing Treat each other with respect Build relationships Promote a culture of innovation and continuous improvement Deliver exceptional results Foster a safe and environmentally responsible culture

Fire Hydrants Fire Hydrants Mueller fire hydrants are known throughout the fire protection industry for superior flow characteristics, dependability, ease of repair, and aftermarket support. Super Centurion hydrants are manufactured in a Mueller ISO 9001 Registered facility in Albertville, Alabama, USA and are backed by a 10-year limited warranty on materials and workmanship. Super Centurion 250 Fire Hydrant (A-423) Super Centurion 250 with Independent Hose Gate Valves (A-423-370) Monitor Style Super Centurion Fire Hydrant (A-479) Super Centurion 250 Features Most widely sold fire hydrant in North America attests to its reliability and value Sealed oil reservoir with automatic pressure lubrication Durable, corrosion-resistant bronze-to-bronze seat mounting Convenient, reversible main valve doubles service life by having a spare already in place Large, smooth radius hose and pumper openings reduce friction loss. Shoe interior epoxy coating inhibits corrosion Meets or exceeds all applicable parts of AWWA C502 & C550, UL246 listed and FM1510 approved 10-year limited warranty Inlet connections: 6 Mechanical Joint, Flanged, D-150 Mechanical Joint, Slip-On & AquaGrip Integral Pipe Restraint Pressure rating: Up to 350psig Monitor Style Features Eliminates possible leak path with separate monitor nozzle attachment Full flow 4-way openings: 4 monitor elbow, one 4 1 /2 pumper nozzle and two 2 1 /2 hose nozzle Integral monitor mounting allows easier monitor nozzle hook-up. All parts interchangeable with Super Centurion 250 hydrant for easy maintenance

Gate and Check Valves Gate and Check Valves Mueller Resilient Wedge Gate Valves feature a forged bronze stem and thrust collar (through 16 ) for superior strength, an elastomer-encapsulated ductile iron wedge and engineered plastic guides to stabilize the wedge and prevent binding. Connection options include: mechanical joint (MJ), flanged (FL), slip-on (SL), radial compression (RAD), and threaded (THD). Styles: NRS, PIV, and OS&Y. Mueller UL listed and FM approved check valves are gravity operated, swing check design. These check valves are rugged in construction and simple in design. Our 2-12 sizes are now rated at 350psig and feature ductile iron construction, EPDM disc seat and bronze body seat rings as standard. 350psi Post Indicator Resilient Wedge Gate Valve (PIV) (P-2361) OS&Y Resilient Wedge Gate Valve (R-2361) 350psi Swing Check Valve (A-2120-6BB) Gate Valves Features 100% encapsulated wedge with extended wedge guides Polymer guide cap bearings on wedge guides resist wear and provide easy operation Smooth, oversized, unobstructed flow way provides superior flow characteristics; reduces pumping costs Mueller Pro-Gard fusion epoxy coating Bi-directional flow 10-year limited warranty Pressure ratings: P-2361 (4-12 ) = 350 psig; R-2361 (2-3 ) = 250 psig, (4-12 ) = 350 psig; R-2361 (14-16 ) = 250 psig; R-2361 (18-24 ) = 175 psig UL Listed/FM Approved (2-24 ) Check Valve Features Ductile iron construction, lifting rings, EPDM disc and bronze body seat rings are standard features Removal of all parts through the top of the valve, without removing the valve from the line Directional arrow leaves no doubt of flow direction Bossed on both sides of the body for connecting bypasses and are bossed at the bottom under inlet end to allow drain valve attachment; tapping is optional Pressure ratings: 2-12 = 350 psig; 14 & 16 = 250 psig

Indicator Posts Indicator Posts Mueller indicator posts are used in fire protection systems and perform several functions. The indicator post provides a means to operate a buried or otherwise inaccessible valve. Also, the indicator post readily and clearly indicates whether the valve is open or shut. Wall-Type Indicator Post (A-20814 4-14 ) Shallow-Bury Indicator Post (A-20806-S 4-14 & A-20807-S 16-24 ) Adjustable Indicator Post (A-20806 4-14 & A-20807 16-24 ) Indicator Post Features Easy to see targets indicates whether the valve is open or closed Designed to withstand up to 900 ft.-lbs. of operating torque Unique operating wrench design makes indicator post tamper-proof Designed to operate 4 through 24 post indicator valves, requiring 14 to 75 turns, respectively, to open For trench depths from 1 4 to over 17 feet. All styles have a cast boss on the upper barrel tapped with 1 /2 NPT to allow for optional supervisory switch installation UL Listed (4-24 ); FM Approved (4-14 )

Delivery and Service The capacity to deliver the widest array of products and stand behind those products to ensure your satisfaction is our strength. The success of Mueller Co. is dependent upon the success of those who are involved, both inside and outside our company. Therefore, we feel our future is wholly dependent on long-term relationships with our employees, customers and suppliers. This is why we strive to be proactive and responsive to their needs, always looking for a better way. It s an approach that has set us apart since 1857 and will assure our mutual achievement and prosperity in the future. Mueller Co. distributors inventory extensive stocks, helping to assure ready availability. Mueller Co. sales representatives, strategically located around the world, are always ready to provide application and installation assistance and help with any special issues. Mueller Sales and Customer Service Mueller Operations Affiliate Operations Follow Us: For more information about Mueller Co. or to view our full line of water products, please visit www.muellercompany.com or call Mueller Customer Service at 1.800.423.1323. Mueller Co., LLC 633 Chestnut St., Suite 1200 Chattanooga, TN 37450 www.muellercompany.com moreinfo@muellercompany.com Toll Free: 1.800.423.1323 Canada: 1.705.719.9965 International: 1.423.490.9555 Copyright 2018 Mueller Co., LLC. All Rights Reserved. The trademarks, logos and service marks displayed in this document herein are the property of Mueller Co., LLC, its affiliates or other third parties. Products above marked with a section symbol ( ) are subject to patents or patent applications. For details, visit www.mwppat.com. These products are intended for use in potable water applications. Please contact your Mueller Sales or Customer Service Representative concerning any other application(s). Form 12589 - Rev 1/18